How do I know that the batteries need to be changed and how to change them?

Your CM67z has built-in electronics that constantly monitor the battery power level. The batteries provided with the unit should last for 2 years. When the batteries require replacement a flashing symbol ( ) will be displayed. To change the batteries: 1. Lift the front flap to reveal the battery compartment. Open the battery compartment by inserting a coin underneath the bottom right edge of the flap and lift it out. 2. Replace the batteries with 2 new AA LR6 alkaline batteries and push the battery compartment firmly back into the unit. The CM67z has a permanent memory to keep your program settings while you change your batteries; you should never need to reprogram. However if you take more than one minute to change the batteries, you may need to correct the time (see section How do I set the date and time?). NOTE: HR80UK radiator controllers in your system are also battery powered. The HR80UK user instruction contains detailed information on when and how to change batteries. RESPECT YOUR ENVIRONMENT Please take care to dispose of used batteries in an environmentally friendly manner. Symptom Blank display on CM67z or HR80UK.

HC60NG Relay Module controls/display

Zone Planning Examples Example 1 Zone 1: Living Room + Kitchen (downstairs) Zone 2: Bedrooms (upstairs)

CM67z
Hydronic Zoning Room Unit

Push button and relay status LEDs

What does it mean when the green LED of the HC60NG is ON? The Green LED indicates normal operation of the system. When the green LED is ON the boiler is also ON. When the LED is OFF the boiler is OFF. You can manually switch the boiler ON or OFF by pressing the push button HR80UK Radiator Controller controls/display
Display Programmed Temperature

Zone 2

USER GUIDE
Zone 1

Example 2 Zone 1: Residential zone Zone 2: Home Office zone

Setting Dial

CMZone Hydronic Zoning provides high levels of comfort and energy savings. The system allows comfort temperatures to be maintained in the part of the house that is occupied, whilst the rest of the house is maintained at a lower more economic temperature. A typical example is a house where the living zone (lounge, kitchen, etc) and bedrooms are controlled separately (see also Zone Planning Examples). System Components

The HR80UK radiator controllers automatically follow the programmed temperature commands of the CM67z. If you wish to adjust the programmed temperature in a room turn the HR80UK dial to set the required temperature (setting range: 530C). You can also open or close the radiator valve completely by turning the dial until the display will show ON or OFF. Possible Cause No batteries. Wrong battery orientation. Improper battery compartment insertion (CM67z only). Exhausted batteries. Remedy

Zone 2

Zone 1

CM67z - Roon Unit The CM67z Room Unit is your command centre which allows you to independently control a number of desired temperature settings in two different zones. You can also switch your heating system off from one central location. HR80UK - Radiator Controller The HR80UK radiator controllers (typically you will have several of them installed in your house) will respond to the temperature commands from the CM67z and will maintain the required temperature level in every room. Your installer should have allocated HR80UKs accordingly to individual zones (e.g. HR80s in lounge and kitchen allocated to zone1, HR80UKs in the bedrooms allocated to zone2). HC60NG - Relay Module The HC60NG Relay Module ensures that your boiler operates efficiently, delivering the heat only when it is required. What will the CM67z do for me? Radio Frequency (RF) communication enables fast and simple installation of the entire system (no need to replumb the heating system or disrupt room decor). Individual weekly programs for each zone with up to 6 temperature changes per day will enable you to maintain comfortable temperatures when and where you need them, whilst minimising your expenses on heating the parts of the house which are not in use. The Holiday button saves energy by letting you reduce the temperature for 1 to 99 days while you are on holiday, returning to normal operation on the day you return. Automatic summer/winter time changes adjust the time settings automatically so your heating system will always start at the right time.
42010707-003 Draft1

Check that the batteries are in the battery compartment and that the paper tab (CM67z only) has been pulled out. Check that the batteries have been installed in the correct orientation. Remove battery compartment and re-insert. Replace the batteries. Replace the batteries. Remove and re-insert the battery compartment. If the spanner symbol ( ) does not clear itself in a few minutes call the installer. Check the power to the HC60NG is on or call the installer. Call electrical installer to check the boiler and HC60NG power supply as well as electrical connection between the boiler and HC60NG. Hook the room unit back on the wall bracket or return the room unit on the table stand to the position where communication was reliable. Call installer - NOTE: You can control boiler manually when RF communication is lost. Press the HC60NG push button to switch the boiler on or off. When the green LED is on - the boiler is on. Replace the HR80UK batteries following the guidelines in the HR80UK user instruction. Hook the room unit back on the wall bracket or return the room unit on the table stand to the position where communication was reliable. Call installer.

CM67z display shows a flashing battery symbol ( CM67z displays a spanner symbol ( ).

).

Batteries need replacing. Fault in the CM67z room unit.

CM67z display works but heating does not switch on: The HC60NG LEDs are OFF The HC60NG green LED is ON

Trouble Shooting Guide

No power to HC60NG. Bad electrical connection to the boiler or faulty boiler. RF communication lost due to bad location of the CM67z room unit. RF communication fault.

HC60NG red LED is constantly ON or flashing.

The HR80UK display is blank or shows bAtt. The ( )symbol on the HR80UK is not displayed.

HR80UK batteries exhausted. RF communication lost due to bad location of the CM67z room unit. RF communication fault.

If you experience any other problems with your heating system please call the installer.

Honeywell Control Systems Ltd., Honeywell House, Arlington Business Park, Bracknell, Berkshire, RG12 1EB

CM67z Room Unit controls/display The diagram below details the key button functions and display information.
1 2 3 4 5

How do I get started with the default time and temperature program? Move the setting slider to AUTO position. The CM67z will now control your heating system according to built-in program. Zone 1 (e.g. living room, dining room, kitchen)
Monday to Friday Program 1 Time 6:30 Temperature 21C Saturday to Sunday Program 1 Time 8:00 Temperature 21C

You have now set the zone1 time temperature program for Monday. You have 2 options to set the program for other days of the week. 6. Press the COPY DAY button to copy the zone1 Monday program to Tuesday. The CM67z will change the day marker to Tuesday. If you repeatedly press the COPY DAY button you can copy the zone1 Monday program to other days of the week. 7. Press the DAY 1..7 button to move the day marker to Tuesday. Repeat the steps described in points 2 to 5 to set zone1 program for Tuesday. Programming zone2 1. Set the CM67z setting slider to z1 z2 the PROG z2 position. Press the PROG 1 button to display 1 2 3 4 5 6 the first temperature change time and temperature level. The flashing display indicates that you can make changes 2. Repeat steps 2 to 7 described in Programming zone1. To start the program for both zones move the setting slider to the AUTO position. What if I do not want to use all 6 temperature time changes? The built-in program uses six temperature change times per day as indicated by the numbers 1, 2, 3, 4, 5 and 6 on the display. Unwanted changes can be deleted by holding appropriate PROG buttons (2, 3, 4, 5 or 6) down for a few seconds. The change time will be removed and the display will show dashes instead of time and temperature display. Pressing the appropriate program button (2, 3, 4, 5 or 6) will restore deleted change times. How do I check the programmed temperature? When in AUTO or OFF mode the CM67z constantly displays the programmed temperature for each zone in the z1 and z2 windows on the display. How can I change the programmed temperature for a short time? You can temporarily override the set temperature in each zone. To adjust the set temperature in a zone press the z1 z2 button to select the zone in which the temperature should be adjusted. The symbol indicates which zone can be adjusted.
z1
MAN OFF

16 15 14 13

DAY 1...7

Mon

Tue

Wed

Thu

Fri

Sat

Sun

z1
COPY DAY
AM

z2
MAN OFF

z1

z2

AUTO MAN OFF

TEMP

2 8:00 18C 2 10:00 21C

3 12:00 21C 3 12:00 21C

4 14:00 18C 4 14:00 21C

5 18:00 21C 5 18:00 21C

6 22:30 16C 6 23:30 16C

You can also adjust the set temperature temporarily in each individual room. Just turn the dial on the radiator controller to set the required value. The temperature in the room will return to the programmed value at the next programmed change. NOTE: If you do not want to allow temporary temperature override at the radiator controller (e.g. in a childs room) ask installer to disable this feature. How do I set one temperature in a zone for the whole day? Press the MAN z1 button to switch zone1 to manual operating mode. The MAN symbol in zone1 will be displayed. Using the or buttons set the required temperature in zone1.
z1
AM

PROG

2
MAN z1

3
MAN z2

z2
OFF MAN OFF

CM67z

AUTO

DATE/ PROG z1 PROG z2 AUTO OFF

Zone 2 (e.g. bedrooms, home office)


Monday to Friday Program 1 Time 6:30 Temperature 21C Saturday to Sunday Program 1 Time 8:00 Temperature 21C 2 8:00 18C 2 10:00 21C 3 12:00 21C 3 12:00 21C 4 14:00 18C 4 14:00 21C 5 18:00 21C 5 18:00 21C 6 22:30 16C 6 23:30 16C

12 1 2 3 4 5 6 7 8

11 9 10 11 12 13 14 15 16

10

Set Temperature for Zone 1 Day Indicator Time Display Operating Mode Symbol Set Temperature for Zone 2 Zone Change Button Temperature Change Buttons Battery Low Indicator

Programming Buttons Holiday Button Manual Override Buttons Setting Slider Zone indicators Time Change Buttons Copy Day Button Day Button

You can cancel manual operating mode for zone1 by pressing the MAN z1 button. To override the zone2 program press the MAN z2 button and set the required temperature as described above. NOTE: MAN z1 and MAN z2 operate independently so you can override zone1 whilst zone 2 will continue to work according to program. You can also override both programs and operate both zones in manual mode. Im going on holiday for a few days. How do I save energy but ensure that the house is warm when I return? 1. Set the CM67z in AUTO position 2. Press the button to display the holiday days counter and temperature 3. Press the + or - button to set the holiday time (1..99 days) 4. Press the TEMP or button to set the holiday temperature (same for both zones, 5C-30C) How can I switch my heating system off? Move the setting slider to the OFF position. In this mode the CM67z limits and controls the temperature to 5C, reducing the risk of your heating pipes from freezing if the temperature falls below 5C. How do I adjust the CM67z for summer/winter time change? Your CM67z has a built-in feature, which will automatically adjust time on the last Sunday of March (winter => summer time) and on the last Sunday of October (summer => winter time). All you need to do is to set the date and time correctly (see paragraph How do I set the date and time?). Can I use CM67z as a room thermometer?

How do I set the date and time? Move the CM67z Room Unit setting slider to DATE/ position. When you set the date and time for the first time after batteries were inserted the CM67z display will show: Press the + or - buttons to set the current year (e.g. 03 = 2003) Press the TEMP
z1 z2

NOTE: Your CM67z Room Unit allows you to use independent programs for 2 zones. Each zone comprises of several rooms. Ask your heating installer to configure the zones to suit your needs (e.g. zone1: living room, dining room and kitchen, zone2: bedrooms, home office). How do I set a personalised heating program? Programming zone1 1. Set the CM67z setting slider to z1 z2 the PROG z1 position. Press the PROG 1 button to display 1 2 3 4 5 6 the first temperature change time and temperature level. Time change numbers The flashing display indicates that you can make changes. 2. Press the + or - buttons to adjust the first change time. Holding the button down will change the time quickly. The time can be set in 10 minute steps from 03:00 in the morning until 02:50 the next morning, allowing the user to maintain the evening temperature beyond midnight. Note: If you are pressing the + or - buttons and the next or previous change time number starts flashing, it means that the time has been changed beyond the next or previous change time. The next or previous time change will be pushed forward or back (respectively) ensuring the program remains in sequence. 3. Press the TEMP or button to adjust the first temperature level. Holding the button down will change the temperature quickly. The temperature can be set in 0.5C increments between 5C and 30C. 4. Press the PROG 2 button to display the second temperature change time and temperature level. Set these by pressing the + or - buttons and TEMP or button. 5. The remaining temperature change times can be displayed by pressing PROG buttons 3, 4, 5 and 6. The displayed change times can be adjusted by using the + or - buttons and TEMP or button (If you do not want to use all the temperature change times refer to What if I do not want to use all 6 temperature change times?).

button to set the month:


z1 z2

Press the + or - to set the current month (e.g. 01 = January) Press the TEMP

button to set the day of the month.


Day of the week indicator
Mon Tue Wed Thu Fri Sat Sun

Press the + or - to set the current day of the month. Check if the day marker on the display indicates the correct day of the week. Press TEMP button to set the time.

z1

z2

z2
MAN OFF

The symbol in the z1 window indicates that the temperature for zone1 can be adjusted.

Press the + or - until the correct time is displayed. Each press of + or - button will change the time by one minute. Holding the button for a few seconds will change the time slowly then quickly. How do I adjust the time

z1

z2

z1
AUTO MAN OFF

z2
AUTO MAN OFF

The symbol in the z2 window indicates that the temperature for zone2 can be adjusted.

The temperature in each room is measured and controlled by the HR80UK radiator controllers. Therefore normally there is no need for the room unit to measure the room temperature. If you want to use the CM67z as a thermometer, please ask your installer to configure the room unit to show the room temperature.
z1 z2
OFF MAN OFF

The temperature measured by the room unit is displayed next to the z1 window.

If you want to adjust the time at any time during normal use of the CM67z move the setting slider to DATE/ position then use + or - button to adjust the time. NOTE: To access the year, month and day setting press TEMP or buttons.

Set the required temperature by pressing the TEMP or button. The temperature will return to program at the next programmed change time. NOTE: As the new set temperature value has to be transmitted to all radiator controllers and then the HC60NG Relay Module it may take up to 4 minutes before all the system will react to the requested change.

AUTO

Note: Due to the distance between the room unit where the temperature is displayed and the HR80UK radiator controller where the temperature is measured there may be a difference between the setpoint and the temperature displayed.