Você está na página 1de 2

The AK 96 machine

Bio version
Developed to deliver unrivaled levels of quality and safety in conventional HD treatments, the Bio version of the AK 96 machine ensures highest fluid quality and top-of-the-range features to further move the boundaries of dialysis treatments. Features available on the Bio version include the full Hygienic Chain, a recorded disinfection history and complete integration with Gambro water treatment systems. Excellence in a dialysis monitor is measured by several variables. The Bio version of the AK 96 machine fulfills them all.

Diascan

Controlled dialsysis dose delivery

Blood pressure monitor

Integrated real-time blood pressure monitoring via patient cuff

U9000 dialysis fluid ultrafilter


Ultrapure dialysis fluid for increased biocompatibility

Arterial blood line clamp and variable dialysate fluid flow


For added economy, reliability and flexibility

Battery back-up

For safe treatments in all environments

The AK 96 machine, Bio version


Consistently high treatment quality Diascan quality control tool U9000 Ultrafilter holder Patient blood pressure supervision Conductivity-based and flow-rate controlled concentrate dosing Disinfection log BiCart cartridge holder

Technical specifications Option Option Blood flow control Flow rate, double needle: 0 and 20 to 500 ml/min Flow rate, single needle: 0 and 20 to 500 ml/min, pressure-controlled Blood circuit pressure supervision Arterial pressure: -700 to +750 mmHg Venous pressure*: -700 to +750 mmHg Air detection Method: Ultrasonic detector Drip chamber size: 22 mm diameter Heparin syringe pump Flow rate: 0 to 10 ml/h Programmable stop time, accumulated volume read-out Water supply Inlet pressure: 0.12 to 0.6 MPa (1.2 to 6 bar) Inlet water temperature during treatment: 5 to 30C Inlet water quality: Fluid must comply with appropriate regulations and as minimum ISO 13959 Dialysis fluid preparation and monitoring Flow rate: 300700 ml/min (by step of 20 ml/min) Acetate range: Na+ 130 to 160 mmol/l Bicarbonate range: Na+ 130 to 160 mmol/l, HCO3- 20 to 40 mmol/l pH measurement: Range 1.0 to 9.9 Profiling (Na+, HCO3-, UF) Concentrate standby mode Ultrafiltration control UF volume: Adjustable, 0 to 10.00 l Accuracy: 50 ml/h or 1% UF rate: 0 to 4 l/h Blood leakage detection Method: Infrared light Disinfection and cleaning Automated disinfection process with Gambro water treatment systems Heat, liquid citric acid or CleanCart disinfectant Chemical: Peracetic acid, hypochlorite or formaldehyde Disinfection log Power supply Mains voltage: 115, 230 V Frequency: 50 to 60 Hz Power consumption: Max 2025W at 230 V, 1575 W at 115 V Connection of external equipment Connector: 25 pin D-sub with RS232C or RS-422/current loop Dimensions and weight Width: Machine 345 mm, stand 585 mm Depth: Machine 600 mm, stand 620 mm Height: 1305 mm Weight: Approx. 60 kg (without options) Operating environment Ambient temperature: 18 to 35 C Relative humidity: 15 to 85% Air pressure: Up to approx. 2500 meters above sea level (70 to 106 kpa)
*An event of venous needle disconnection is not guaranteed to be detected by most dialysis machines. International standards recommend additional venous access monitoring is used to safeguard patient safety.

Syringe pump Alarm pole pH probe Operational efficiency Automatic self-test Stand-by mode Profiling modules Assisted priming Variable dialysate fluid flow Automated heat disinfection processes Concentrate standby mode Ease of use and staff satisfaction Single needle mode Auto rinse back Automatic switch from isolated UF to diffusion Decalcification and cleaning with CleanCart cartridges Pre-settable for different disinfectants Pre-configuration options (start-up values, limits, limitations) Battery back-up Prepared for Softpac concentrate

Safety The AK 96 machine complies with the following standards: IEC 60601-1 General requirements for safety, Class I, type B IEC 60601-2-16 Particular requirements for safety of hemodialysis, hemodiafiltration and hemofiltration equipment IEC 60601-1-1 Safety requirements for medical electrical systems IEC 60601-1-2 Electromagnetic compatibility, class B IEC 60601-2-30 Particular requirements for the safety of automatic cycling indirect blood pressure monitoring equipment EN 1060-1 Non-invasive sphygmomanometers Part 1: General requirements EN 1060-3 Non-invasive sphygmomanometers Part 3: Supplementary requirements for electromechanical blood pressure measuring systems Gambro is a registered trademark of Gambro Lundia AB AK 96 is a trademark of Gambro Lundia AB registered in the European Community, China and in other countries and filed in the United States Diascan is a trademark of Gambro Lundia AB/Gambro Hospal Switzerland ltd registered in the United States, China and in other countries and filed in the European Community CleanCart is a trademark of Gambro Lundia AB/Gambro Hospal Switzerland ltd, registered in China and in other countries and filed in the United States U9000 is a trademark of Gambro Lundia AB, registered in the European Community Specifications subject to change without notice. For further information and operating instructions, please refer to the operator manual

Gambro Lundia AB PO Box 10101, SE-22010 Lund, Sweden Phone + 46 46 16 90 00 partner@gambro.com, www.gambro.com

HCEN5238_3 2009.01. Gambro Lundia AB