Coolant Standard
The following standard is intended for use in the analysis of metals in ethylene glycol or other coolants. It can be diluted 1:1 with ethylene glycol (for matrix matching) or in dilute nitric acid. Matrix: 1% HNO3, tr. HF . Volume (mL ) 500 Element Al B Ca Cu Fe K Mg Conc. (g/mL ) 50 1,000 50 50 50 1,000 50 Product No. GLYCOLSTD-500 Element Mo Na P Pb Si Zn Conc. (g/mL ) 500 1,000 2,500 50 500 50
NEW!
NEW!
Analyzing
Biodiesel?
NEW!
Petroleum Standards
Crackle T est references for determining water in oil (all values nominal). The crackle test is a visual test performed by placing a small drop of oil onto a hot plate (usually around 300C). The amount of water present in oil samples is estimated by comparison to these standards. certified by gravimetric preparation. All values Standards for Used Oil Analysis Wear Metals
Nominal Water Concentration (% ) Blank 0.1% 0.5% 1.0% Volume (mL) 250 250 250 250 Product No.
Coolant Fuel Dilution Water in Oil Soot Standards for S, N, Cl and Metals Petroleum Physical Test Standards
NEW!
Karl Fischer Titration certified reference standards for determining water in motor oil (all values certified by Karl Fischer Titration). This test determines the amount of water present in the oil and is the most commonly-used test for this type of determination, with a high degree of accuracy. For use with ASTM D6304.
Nominal Water Concentration (% ) Blank 0.1 0.5 1.0 Volume (mL) 100 100 100 100 Product No. KF-BLK-100 KF-0.1%-100 KF-0.5%-100 KF-1.0%-100
NEW!
Reference standards for use in the determination of soot content in 15W40 diesel motor oil by infrared spectroscopy or other technique. All values certifed by thermogravimetric analysis (TGA).
Nominal Soot Content Range (% ) Blank 0.5-2 2-4 4-6 6-9 9-12 Set of all 6
Volume (mL) 50 50 50 50 50 50 6 x 50
NEW!
Sulfur QC Samples, Drift Monitors and Calibration Standards Made from Polysulfide oil
VHG Labs' polysulfide oils have been formulated for long shelf life and optimal stability even when exposed to x-rays from modern high wattage XRF spectrometers. In addition, our polysulfide oil products offer high purity, low volatility, and minimal diffusion through sample films.
These standards are well suited to ultra low level sulfur analysis, quality control, drift correction, blank measurement and calibration standards for XRF and other sulfur analysis techniques. Our polysulfide oil standards are intended for use in accordance with the newly revised ASTM D2622, D4294, D5453, D7039, D7212, D7220 and others.
Description
QC Samples Sulfur @ 5g/g, Polysulfide oil, 1L Sulfur @ 10 g/g, Polysulfide oil, 1L Sulfur @ 2 5g/g, Polysulfide oil, 1L Drift Monitors Sulfur @ 10 g/g, Polysulfide oil, 1L 0 Sulfur @ 2 50 g/g, Polysulfide oil, 1L Sulfur @ 50 g/g, Polysulfide oil, 1L 0 Sulfur @ 1,0 0 0 g/g, Polysulfide oil, 1L Blank Polysulfide Oil Blank Calibration Sets Sulfur Standard Set (low concentrations). Set of 13 Calibration Standards with Sulfur @ 0, 1, 2.5, 5, 10, 25, 50, 75, 100, 250, 500, 750, 1000g/g, made from high purity polysulfide oil, 50mL each Sulfur Standard Set (high concentrations). Set of 12 Calibration Standards with Sulfur @ 0, 0.1, 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 4.5 and 5wt%, made from high purity polysulfide oil, 50mL each Sulfur Standard Set (low concentrations). Set of 6 Calibration Standards with Sulfur @ 0, 10, 25, 50, 100 and 250g/g, made from high-purity polysulfide oil, 50mL each
Product No.
X3SPS-BLK-1L
X3SPS-SET1-13X50mL
X3SPS-SET2-12X50mL
X3SPS-SET3A-6X50mL
Petroleum Standards
Section 1 Petroleum
Standards
Standards for Used Oil Analysis Standards for S, N, Cl and Metals Sulfur-Free MetalloOrganics Nitrogen Sulfur and Metals Sulfur Chlorine Lead in Gas Petroleum Physical Test
250mL bottles and are accompanied with a certificate verifying the determined value. Volume: 250mL Nominal Freezing Point (C): Product No.: -50 F50-250 -45 F45-250
NEW!
ASTM D86 Group 1 & 2 Synthetic Distillation Standard
The automatic distillation apparatus duplicates the distillation conditions of the manual method. The increased reliance on electronic control requires an independent standard to verify that the apparatus is performing correctly. VHG has introduced a synthetic blend of hydrocarbons that boil in the temperature range specified in ASTM D86 distillation groups 1 and 2. The Group 1 and 2 standard covers the boiling range 129 F to 368 F (54 to 187 C) and was verified by , consensus analysis with twelve refinery laboratories. Description Synthetic Distillation Standard 0.5L Product No. D86-500
Group 1 & 2 Distillation Range IBP 10% 50% 90% EP 129 F 180 F 228 F 319 F 368 F
Petroleum Standards
Standards for Used Oil Analysis Standards for S, N, Cl and Metals Petroleum Physical Test Standards Flash Point Viscosity Pour Point Cloud Point Freezing Point Distillation TAN, TBN
Acid number is defined as the quantity of base expressed as milligrams of potassium hydroxide per gram of sample, required to titrate a sample to a well defined inflection point as specified in ASTM D 6 4 4 .
NEW!
Total Base Number (TBN Reference Materials)
VHG Labs TBN reference materials are intended for use in the determination of T otal Base Number (TBN) in petroleum products by potentiometric titration. ASTM D2896 and IP276 or ASTM D4739. Matrix *Certified Value (mg KOH/g) Mineral Oil Mineral Oil Mineral Oil Mineral Oil Mineral Oil Mineral Oil 6 10 15 30 40 70 Size (grams) 50 50 50 50 50 50 TBN-6-50 TBN-10-50 TBN-15-50 TBN-30-50 TBN-40-50 TBN-70-50 Product Number Our TBN standards are intended for use in accordance with
*Base number is defined as the quantity of perchloric acid, expressed in terms of the equivalent number of milligrams of potassium hydroxide that are required to titrate 1g of the sample, dissolved in the specific solvent to a well defined inflection point as specified in ASTM D 28 6 9 .