Escolar Documentos
Profissional Documentos
Cultura Documentos
ANNEXURE1
PowertechConstructionsPvt.Ltd
Title : REVISED PRICE SCHEDULE FOR Amendment - 2 Sr. No. Particulars QTY Unit Unit 1 1.1 Transformers Unloading, Installation, testing & commissioning of the following oil immersed transformers, including charges for specified site tests: a) 40/50 MVA, 132/33 kV,dyn11 Power transformer with OLTC along with RTCC panel 1.2 Supply of necessary rails (90 LB) and embedments shall form part of the scope. Total in Rupees 3 3.1 Clients 132kv switchyard Incoming bay Motorised 132KV, 1250A, 31.5 kA Horizontal Double Break Isolator complete with insulators control gear etc. (for APTCL) suitable for polluted area a. with earth switch b. without earth switch 132 kV SF6 1250A, 31.5 kA circuit breakers Line Metering & Protection-3 core Core -1 : 300-150/1A, CL-0.2, 30VA Core -2 : 300-150/1A, CL-5P20, 30VA Core -3 : 300-150/1A, CL-PS, Vk=650 V 4 Transformer bay Nos 2 No. Supplied by Client Supply Unit Rate Revised Total Amount
Rev:2
Unit Rate
Total
95200
190400
16 M
2784
44544
91
1456
44544
191856
3.2 3.3
Page1of10
M/s.AnjaneyAlloysLtd.
ANNEXURE1
PowertechConstructionsPvt.Ltd
Sr. No.
Particulars
QTY
Unit Unit
REMARKS
4.1
Motorised 132KV, 1250A, 31.5 kA Horizontal Double Break Isolator complete with insulators control gear etc. (for APTCL) a. with earth switch b. without earth switch
4.2 4.3
132kV SF6 1250A, 31.5 kA circuit breakers Transformer Metering & Protection-3 core Core -1 : 300-150/1A, CL-0.2, 30VA Core -2 : 300-150/1A, CL-5P20, 30 VA Core -3 : 300-150/1A, CL-PS, 40/50MVA Tranmsformer Neutral CTs 1200/1A, Cl: PS 1200/1A, Cl: 5P10, 20VA Single phase oil cooled potential transformers- 2 core 132 KV / 110V / 110V 3 3 3 Class - 0.2, 50 VA Class - 3P, 50 VA 120KV, 10KA, Lightning Arrestor Complete with base and discharge counter. I)Junction Boxes for the instrument transformers II) Marshalling Box Switchyard structure comprising of GI structures, GI nuts, and bolts and foundation bolts Bus bar materials ( qnty indicated are tentative ) - ACSR Moos conductor (50Hz) for over head bus
4.4
4.5
Page2of10
M/s.AnjaneyAlloysLtd.
ANNEXURE1
PowertechConstructionsPvt.Ltd
Sr. No.
Particulars
QTY
Unit Unit
REMARKS
4.9.2 4.9.3 4.9.4 4.9.5 4.9.6 4.9.7 4.9.8 4.9.9 4.9.10 4.9.11 5
Rigid clams & connectors CT'sPT's Isolators LA's Transformer Breaker Bus post clamp T-connectors suitable for Moose condocdor PG / Tension clamps for ACSR conductors and shield wire Insulators I)Tension string insulators suitable for 132 KV system II)S i t i insulators S it bl f 132 KV system t II)Suspension string i l t Suitable for III) 132 KV Bus post solid core type insulators Control & Relay Panels 40/50MVA 132/33KV Trnasformer C&R panel 132kv Incoming Contorl & Relay panel Total in Rupees Cable Trays & Accessories Galvanised cable trays of ladder type, for the above cables alongwith supports. Trays for switchyard area be consideredonly to - 450 mm wide cable tray (inside switchard only) - 300 mm wide cable tray (inside switchard only) - 150 mm wide cable tray (inside switchard only) - Supports for cable trays (inside switchard only) Total in Rupees 33KV Switch yard 33KV, 31.5 kA Horizontal Double Break Isolator complete with 2 nos of 22kv insulators stack etc. a. 1600A with earth switch b. 800A with earth switch 18 Sets 9 S t Sets 22 Nos 2 Nos 2 Nos 10767 9435 11988 193806 84915 263736 11046430.5 1776000 1630000 3406000 546 546 910 9828 4914 20020 514412 32760 32760 65520 for Distance relay
888000 815000
16380 16380
M M M MT
41 40 25 13830
8 8.1
2 Sets 8 Sets
91640 68440
183280 547520
2730 2730
5460 21840
Page3of10
M/s.AnjaneyAlloysLtd.
ANNEXURE1
PowertechConstructionsPvt.Ltd
Sr. No.
Particulars
QTY
Unit Unit
Supply Unit Rate 80040 60320 68440 41850 Revised Total Amount 80040 1206400 547520 251100
Installation Unit Rate 2730 2730 2730 2730 Total 2730 54600 21840 16380
REMARKS
c. 1600A without earth switch d. 800A without earth switch e. 800A with earth switch 8.2 1200/1-1-1A, Current Transformer Metering & Protection- 3core Core -1 : 1200/1A, CL-0.2, 30VA Core -2 : 1200/1A, CL-5P20, 30 VA Core -3 : 1200/1A, CL-PS, 600/1-1-1A, Current Transformer Metering & Protection 3 core Protection-3 Core -1 : 600/1A, CL-0.2, 30VA Core -2 : 600/1A, CL-5P20, 30 VA Core -3 : 600/1A, CL-PS, 8.4 150/1-1A, Current Transformer Metering & Protection-3 core Core -1 : 150/1A, CL-0.2, 30VA Core -2 : 150/1A, CL-5P20, 30 VA 75/1-1A Current Transformer Metering & Protection-3 core Core -1 : 75/1A, CL-0.2, 30VA Core -2 : 75/1A, CL-5P20, 30 VA Single phase oil cooled potential transformers- 2 core 33 KV / 110V / 110V 3 3 Core 1 - Class 0.5, 50 VA Core 2 - Class 3P, 50 VA Single phase oil cooled potential transformers- 1 core 3
8.3
12 Nos.
34635
415620
2730
32760
12 Nos.
34635
415620
2730
32760
8.5
24 Nos.
34635
831240
2730
65520
8.6
6 Nos.
34292.3
205753.8
2730
16380
8.7
6 Nos.
37292.3
223753.8
2730
16380
Page4of10
M/s.AnjaneyAlloysLtd.
ANNEXURE1
PowertechConstructionsPvt.Ltd
Sr. No.
Particulars
QTY
Unit Unit
REMARKS
30KV, 10KA, Station class Lightning Arrestor Complete with base and discharge counter. I)Junction Boxes for the instrument transformers Switchyard structure comprising of GI structures, GI nuts, and bolts and foundation bolts Bus bar materials ( Double bus bar system ) - ACSR Twin moose conductor (50Hz) for over head bus Rigid clams & connectors BreakersCT's PT's Isolators LA's Capacitor Bus post clamp T-connectors suitable for Panther condocdor Spacers Insulators I)Double Tension string insulators suitable for 33 KV system II) single Tension string insulators suitable for 33 KV system III)Suspension string insulators Suitable for 33KV system IV) 22 KV Bus post insulators (2 nos per set) Cables and Terminations 33 KV Cables & Terminations
18 Set 22 Nos. 1 LS 1 LS
11
12 12 6 78
12 12.1
Page5of10
M/s.AnjaneyAlloysLtd.
ANNEXURE1
PowertechConstructionsPvt.Ltd
Sr. No.
Particulars
QTY
Unit Unit
REMARKS
Laying of 33 kV (E) C x 630 sq. mm grade stranded, aluminium conductor, XLPE insulated, armoured PVC overall sheathed, to bury in underground trenches or overhead trays having following sizes to run on cable trays cables between switch boards / transformers Engraved aluminium tags shall be provided at both the ends of cables for identification purpose. a) 33 kV cables: 1Cx630 Sq.mm XLPE Cable (Approx) Termination shall include termination kits (for 33 kV cables), including all terminating materials and ferrules complete of all termination.with supply b) Termination kits for the above: a. Outdoor Termination for 1Cx630 Sq.mm XLPE Cable 12.2 1.1 KV Cables (Laying & Terminations) 1.1 kV Grade PVC insulated, PVC sheathed armoured power and control cables and termination arrangements, for Switchyard including control cables of generator transformer, RTCC panel, Distribution transformers and converter transformers I) Power Cables- Laying a) 3.5 C x 150 sq. mm Al. Cable b) 3.5C x 35 sq. mm Al. Cable c) 2C x 10 sq. mm Al Cable a) b) c) d) e) f) g) Control Cables (Cu)-Laying 19 C x 2.5 Sq.mm Cable 14 C x 2.5 Sq.mm Cable 7 C x 2.5 Sq.mm Cable 5 C x 2.5 Sq.mm Cable 4 C x 4 Sq.mm Cable 3 C x 2.5 Sq.mm Cable 2 C x 4 Sq.mm Cable
1450 M
927.4138
1344750
48.9310345
70950
24 Nos 1 LS
6771 3609993
162504 3609993
910 285655
21840 285655
II)
Page6of10
M/s.AnjaneyAlloysLtd.
ANNEXURE1
PowertechConstructionsPvt.Ltd
Sr. No.
Particulars
QTY
Unit Unit
REMARKS
III)
Power Cables- termination a) 3.5 C x 150 sq. mm Al. Cable b) 3.5C x 35 sq. mm Al. Cable c) 2C x 10 sq. mm Al. Cable a) b) c) d) e) f) g) Control Cables (Cu)-Termination 19 C x 2.5 Sq.mm Cable 14 C x 2.5 Sq.mm Cable 7 C x 2.5 Sq.mm Cable 5 C x 2.5 Sq.mm Cable 4 C x 4 Sq.mm Cable 3 C x 2.5 Sq.mm Cable 2 C x 4 Sq.mm Cable Earthing & Lightning Protection Earthing & Lightning protection for switchard including neutral / body earthing of 16/20MVA trafo. Furnace trafo. and Distribution trafo. - 7/9 SWG Shield wire - 75 x 10 GI Flat (main earth mat) - 50 x 6 GI Flat (Eqpt./cable tray) - 8 SWG GI Wire (Fencing) - Treated earth pits 100 mm dia, 2.7M long CI pipe electrode (PT/FT/DT/Switchyard area) 1 LS 2023844 5117247 378445
IV]
13
2023844
383998.7
383998.7
a) b) c) d) e) h)
Total in Rupees 14 33 KV outdoor Breakers 33 KV VCB 26.3 KA Panel ( As per SLD and specifications) 2 Nos 287500
2023844
383998.7
575000
13650
27300
Page7of10
M/s.AnjaneyAlloysLtd.
ANNEXURE1
PowertechConstructionsPvt.Ltd
Sr. No.
Particulars
QTY
Unit Unit
Supply Unit Rate 287500 287500 303051 303051 303051 303051 0 Revised Total Amount 2300000 2300000 5175000 2424408 606102 1212204 1212204 5454918
Installation Unit Rate 13650 13650 7735 7735 7735 7735 91000 Total 109200 109200 245700 61880 15470 30940 30940 728000 867230
REMARKS
14.2 O/G -1600A 14.3 800A for capacitor bank Total in Rupees 15 33Kv C&R Panels 15.1 Capcitor bank control & Relay Panel 15.2 33KV Breaker Control and Relay panel 15.3 2.5MVA Transformer Control & Relay Panel 15.4 Furnace transformer breaker Control & Relay Panel 15.4 7.9MVAR & 3.8MVAR Capacitor bank with NCT 16 16.1 16.2 Miscellaneous items: Battery charger cum DC DB with 110 V DC 200 AH rating with VRLA batteries sets stand , charger. DCDB (Control Room )- with 160A, 2 pole MCCB incomer outgoings. MCBs shall be suitable for DC duty.,3 nos 63 A DP , 9nos 32A DP MCB ACDB ( Control Room )- with 1 No.200A, TPN MCCB incomer and 2 nos 125 A TPN MCCB , 2 Nos of 63A and 2 Nos out going feedersof 32A TPN MCB Outdoor IP 65 DCDB ( Switchyard)- with 63A, 2 pole MCB incomer outgoings. MCBs shall be suitable for DC duty.and 15nos 16A, 2 pole MCB Outdoor IP65 ACDB ( Switchyard)- with 1 No.125A, TPN MCCB incomer and 1 No 100A MCCB and 6 Nos out going feedersof 16A TPN MCB Total in Rupees Lighting Switchyard Lighting :
1 No. 1 No
577448
577448
22750
22750
60611
60611
4550
4550
16.3
1 No.
57304
57304
4550
4550
16.4
1 No.
24244
24244
4550
4550
16.5
1 No.
41876
41876 761483
4550
4550 40950
17 17.1
1 LS
205170.1
205170.05
32500
32500
Page8of10
M/s.AnjaneyAlloysLtd.
ANNEXURE1
PowertechConstructionsPvt.Ltd
Sr. No.
Particulars
QTY
Unit Unit
Supply Unit Rate 178739.3 940734 Revised Total Amount 178739.25 940734 1324643.3
REMARKS
17.2 17.3
Control room building elecrification Power Transformer Fire protection system Total in Rupees
1 LS 1 LS
18 18.1
Switchyard Engineering & Site services Engineering for switchyard including preparation and submission of engineering drawings, documents as specified in the tender Statutory approval Preparation & submission of complete drawings for the statutory authority / Electrical safety authority approval, certificates for the complete installation under the arranging for inspection and getting safety scope. Carrying out of pre-commissioning checks for the complete equipment in the scope of erection & commissioning.The verification of relay configuration and settings shall also include numeric relays by the relay manufacturer. Charges for submission and obtaining approval from APTCL for the equipment, structures, related drawings / documents and erection work under APTCL's supervision scope. This scope also includes the charges for arranging inspection and obtaining necessary clearances from APTCL for the equipment under APTCL supervision scope. Total in Rupees SUMMARY Transformers Clients 132KV switchyard 132 kv Control Panels
1 LS
250000
250000
18.2
1 LS 300000 300000
18.3
18.4
1 LS 100000 100000
1 2 3
Page9of10
M/s.AnjaneyAlloysLtd.
ANNEXURE1
PowertechConstructionsPvt.Ltd
Sr. No.
Particulars
QTY
Unit Unit
Supply Unit Rate Revised Total Amount 1659314 9022040 5117247 2023844 5175000 5454918 761483 1324643.3 1447092 46482555.9 TOTAL
Installation Unit Rate Total 147115 730074 378445 383998.7 245700 867230 40950 179237.63 1050000 4794538.33 51277094.2
REMARKS
4 5 6 7 8 9 10 11 12 13
Cable Trays & Accessories 33KV Switchyard Cables and Terminations Earthing & Lightning Protection 33 KV outdoor Breakers 33kv Control & Relay Panels Miscellaneous items: Lighting Switchyard Engineering & Site services Spare
Page10of10