Você está na página 1de 35

SUBNETWORK_ID

SubNetwork Id
INTEGER: 0 to 4095

41

BTS_NAME

NE_ID

NE_IP

SDR_TYPE

BTS Name

NE ID

NE IP Address

SDR Type

80 characters at most

BS8700,BS8800 GU360,BS8800 U240,BS8800 INTEGER: 0 to 65535. O&M IP of Node B, U120,BS8800 should be unique in the should be unique in the U120A,BS8900 whole subnetwork. whole network GU360,BS8900 Index of all sheets U240,BS8800 GU360 E,BS8900 GU360 E,BS8900A,BS8906

MP08BDNGR012&Chirola

95

118.41.95.100 BS8900A

SDR_VERSION

RNC_ID

BSC_ID

LONGITUDE

LATITUDE

SDR Software Version

RNC ID

BSC ID

Longitude

Latitude

INTEGER: 0 to 4095. 4.09.21.05,4.09.21.05P GSM single-mode base 01 station does not need to fill in.

INTEGER: 0 to 65535. RANGE: -180 to 180. UMTS single-mode Accurate to six digits base station does not after the decimal point need to fill in.

RANGE: -90 to 90. Accurate to six digits after the decimal point

4.09.21.05P01 65535

41

180.0

90.0

LOCATION

VENDOR_NAME

USER_DEFINED_STATE

Location

Vendor Name

User Defined State

40 characters at most. Can be blank.

40 characters at most. Can be blank.

80 characters at most. Can be blank.

zte

MP08BDNGR012&Chirola

NE_ID

RADIO_MODE

CC_SLOT

FS_SLOT

PM_SLOT

NE ID

Radio Mode

CC Slot

FS Slot

PM Slot

Pattern:slot,... Slot INTEGER: 0 to 65535. range: 1,2; Configured should be unique in the UMTS,GSM,GSM+UM as "1,2" if there are two whole subnetwork. TS CC boards. The board Index of all sheets in slot 1 must be configured.

Pattern:slot,... Slot Pattern:slot,... Slot range: 14,15; range: 3,4; Configured Configured as "14,15" if as "3,4" if there are two there are two PM FS boards. boards.

95

GSM

14

BPC_SLOT

UBPG_SLOT

SE_SLOT

TAM_BOARD

TAM_SLOT

BPC Slot

UBPG Slot

SE Slot

TAM Board Type

TAM Board Slot

Pattern:slot,... Slot range:4 to 8, UMTS parameter. For example:6,7,8

Pattern:slot,... Slot range:4 to 8, GSM parameter. For example:5,6,7

INTEGER: 5 to 8

0:TAM0;1:TAM1. Keep blank if TAM board is INTEGER: 4 to 8 not configured

TAM_WORKING_CURRENT

UES_SLOT

RACK_TOPOLOGY

BATTERY_SAVING

EPM_PWR_TYPE

TAM Normal Working Current(mA)

UES Board Slot

Rack Topology

Energy Saving Mode

Embedded power device Type

TAM0:75 to 400; TAM1:75 to 600

INTEGER: 3 to 8

Pattern:1-RU-RU-...,1RU-RU-... For example, "1-2-3,1-4,151-52" means RSU2 and RSU4 and RRU51 connect with the main Y:Function opened, rack, RSU3 connects N:Function closed with RSU2, RRU52 connects with RRU51. Each optical port cascade up to four RU. Keep blank if there is no cascade connection.

ZXDU58 B900,ZXDU B121,ZXDU4575,ZXDU150

1-2,1-4,1-6

ZXDU45-75

EPM_DEAL_MODE

Embedded power data processing mode

0:Transparent transmission,1:Parse

NE_ID

NTP_SERVER_IP

TIME_ZONE

SUMMER_TIME_START

SUMMER_TIME_END

NE ID

NTP Server IP Address

Time Zone

Summer Time Start

Summer Time End

INTEGER: 0 to 65535. should be unique in the IPV4 whole subnetwork. Index of all sheets

Pattern: MM-DD Pattern: MM-DD Please refer to the help HH:mm, Fill in '0' if not HH:mm, Fill in '0' if not documentation used used

95

139.41.0.254

GMT + 5:30

NE_ID

CLOCK_ID1

CLOCK_ID2

CLOCK_ID3

CLOCK_SYNC_MODE

NE ID

Clock Source Priority 1

Clock Source Priority 2

Clock Source Priority 3

Clock Synchronization Mode

0:GSM/UMTS Frequency Sync; 1:GSM FrameNumber INTEGER: 0 to 65535. Sync. UMTS GPS,BITS-2MHz,BITS- GPS,BITS-2MHz,BITS- GPS,BITS-2MHz,BITSshould be unique in the Frequency Sync; 2Mbps,Line,1588,Sync 2Mbps,Line,1588,Sync 2Mbps,Line,1588,Sync whole subnetwork. 2:GSM Frequency E E E Index of all sheets Sync. UMTS FrameNumber Sync; 3:GSM/UMTS FrameNumber Sync

95

Line

GPS_CABLE_TYPE

GPS_RECEIVER_TYPE

GPS_FEEDER_DELAY

GPS Cable Type

GPS Receiver Type

GPS Antenna Feeder Delay(ns)

0:One Cable Input; 1:Two Cables Input

0:Build-in; 2:Slave Shelf

INTEGER: 0 to 32767

NE_ID

TRANSMISSION_TYPE

TRANSMISSION_MEDIUM ETHERNET_WORK_MODE

FE_BANDWIDTH

NE ID

Transmission Type

IP Transmission Medium

Ethernet Work Mode

FE/GE BandWidth(kbps)

INTEGER: 0 to 65535. should be unique in the IP,ATM,ATM+IP whole subnetwork. Index of all sheets

FE,E1,T1,FE+E1,FE+T INTEGER: 100 to Auto,1000M,100M,10M 1 1000000, Step 100

95

IP

E1

FE_LINK_TYPE

OMCB_GATEWAY_IP

OMCB_QOS

OMCB_IP_NO

IPCLK_SYNC_SERVER_IP

OMCB Gateway IP FE/GE Link Type Address

OMCB Qos

OMC-B IP No.

1588 Sync server IP Address

RNC/BSC/CN,SDR

IPV4

BE: Try the best. EF: EF service, Expedited Forwarding, Minimum Delay, Maximum flow. AF42: Class-4 service with medium discarding priority. AF22: Class-2 INTEGER: 0 to 19, service with medium existed in IP sheet. discarding priority. AF43: Class-4 service with high discarding priority. AF23: Class-2 service with high discarding priority

Must be configured for IP 1588 clock reference source(GIPI interface IP). Valid only when it is IP over Ethernet transmission type.

118.41.0.1

BE

IPCLK_IP_NO

IPCLK_QOS

1588 IP No.

Ip Clock Qos

INTEGER: 0 to 19, existed in IP sheet.

BE,EF,AF42,AF22,AF4 3,AF23

NE_ID

IP_NO

IP_VLAN_ID

IP_VLAN_IP_ADDR

IP_VLAN_MASK

NE ID

IP No.

IP Vlan No.

IP VLAN IP Address
IPV4

IP VLAN Subnet Mask

INTEGER: 0 to 65535. should be unique in the INTEGER: 0 to 19 whole subnetwork. Index of all sheets

INTEGER: 2 to 4094. 65535:Invalid

95

IP_VLAN_GATEWAY

PPP_NO

PPP_HDLC_NO

PPP_IP_ADDRESS

PPP_PROTOCOL

IP VLAN Gateway IP
IPV4

PPP No.

PPP HDLC Link No.

PPPoE IP Address PPP Encapsulation

INTEGER: 0 to 7. MLPPP: 0 to 2

Pattern: hdlc No.,... PPPoE ip address. hdlc No.:0 to 15, 8 links "0.0.0.0" represents at most automatic allocation.

PPP,ML-PPP

118.41.95.100 ML-PPP

PPP_LINK_TYPE

PPP_COMPRESSION

MP_HEAD

MP_PRIORITY

PPP Link Type

Support IP compress or not


N:non-support, Y:support

MP Head

MP Priority

RNC/BSC/CN,SDR

LONG,SHORT,INVALI 1,2,3,4,INVALID D

RNC/BSC/CN

SHORT

NE_ID

SCTP_NO

SCTP_RADIO_MODE

SCTP_LOCAL_PORT

SCTP_REMOTE_PORT

NE ID

SCTP No.

SCTP Radio Mode

SCTP Local Port

SCTP Remote Port

INTEGER: 0 to 65535. should be unique in the INTEGER: 0 to 3 whole subnetwork. Index of all sheets

GSM,UMTS

UMTS:0 to 65535;GSM:1 to 1536

UMTS:0 to 65535; GSM: iBSC CMP Module No. + 0x3900

95

GSM

95

14598

SCTP_REMOTE_IP

SCTP_INOUT_STREAM

SCTP_QOS

SCTP_IP_NO

PATH_DOMAIN

SCTP Remote IP Address

SCTP InOut Stream

SCTP Qos

IP No.

Path Domain

IPV4

INTEGER: 1 to 6

BE: Try the best. EF: EF service, Expedited Forwarding, Minimum Delay, Maximum flow. AF42: Class-4 service with medium discarding priority. AF22: Class-2 INTEGER: 0 to 19, service with medium existed in IP sheet. discarding priority. AF43: Class-4 service with high discarding priority. AF23: Class-2 service with high discarding priority

INTEGER: 0 to 3, 255:Invalid. UMTS multi-path parameter, OMCR docking parameter is: Omcb Path-Omcb Module

97.146.166.93 2

EF

255

NE_ID

HDLC_NO

E1T1_LINK_ID

E1T1_LINK_TYPE

HDLC_TIMESLOT_MAP

NE ID

HDLC No.

E1/T1 Link No.

E1/T1 Link Type

HDLC Timeslot

INTEGER: 0 to 65535. should be unique in the INTEGER: 0 to 15 whole subnetwork. Index of all sheets

INTEGER: 0 to 15. 8 to 15 is the E1/T1 link id RNC/BSC/CN,SDR of SE which is plugged in slot 5.

Pattern:start of time slot-end of time slot,... Slot 1 to 31(T1 is 24) can be used. Slot 0 is excluded.

95

RNC/BSC/CN

1-31

TSI_IN_TIMESLOT_MAP

TSI_OUT_LINK_ID

TSI_OUT_TIMESLOT_MAP

TSI In Timeslot

TSI Out Link ID

TSI Out Timeslot

The pattern is same as The pattern is same as HDLC timeslot. The HDLC timeslot. can not INTEGER: 0 to 15. number of out&in overlap with the HDLC should be filled in case timeslot must be timeslot. should be of time slot identical. should be filled in case of time interchange, otherwise filled in case of time slot interchange, keeping empty. slot interchange, otherwise keeping otherwise keeping empty. empty.

NE_ID

RU_NO

RRU_NAME

RADIO_MODE

BOARD_TYPE

NE ID

RU No.

RU Name

Radio Mode

Board Type

INTEGER: 0 to 65535. 60 characters at most, should be unique in the RSU2 to 25, RRU: 51 can be blank. without whole subnetwork. to 74 <>&'" Index of all sheets

UMTS,GSM,GSM+UM Please refer to the help TS documentation

95 95 95

4 6 2

ZXSDR RSU60(4) GSM+UMTS ZXSDR RSU60(6) GSM+UMTS ZXSDR RSU60(2) GSM+UMTS

RSU60E-GU908 RSU60E-GU908 RSU60E-GU908

DOWNLINK_FREQ

UPLINK_FREQ

FS_PORT

OPTICAL_MODULE_TYPE

RX_EXTENSION_RU

Central Downlink Frequency(MHz)

Central Uplink Frequency(MHz)

FS Port

Optical Module Type

Rx RF Extension RU No.

Multiple of 0.2MHz. 0 or blank represents Multiple of 0.2MHz. 0 or automatical calculation blank represents First FS: 0 to 5, Second by Node B. When automatical calculation FS: 20 to 25 downlink frequency is by Node B not 0, uplink frequency should not be 0.

1.25G,2.5G. R8880,R8882,R8890,R SU82 series can set 2.5G. All of RU linked to same FS port must be identical.

The frequency band of associated RU should be identical. Each RU can only be associated once.

0 0 0

0 0 0

2 4 0

1.25G 1.25G 1.25G

RX_PORT_ANTENNA

ANTENNA_TYPE

TM_TYPE

RX_POWER_GAIN

TX_POWER_GAIN

Connected to an Antenna or not

Antenna Type

Tower Top Amplifier type

Tower Top Amplifier Uplink Power Gain

Tower Top Amplifier Downlink Power Gain(0.1db)

N: Does not connect to an antenna, Y: connect ANT:Normal Antenna, to an antenna. If setting RET:Aisg Y, Rx RF Extension RU can not set.

TMA,A-TMA,ETMA,AETMA. This parameter and the following four parameters is valid when the antenna is RET.

TMA:110 to 130(0.1dB); A-TMA:44 to 100(0.25dB); ETMA:230 to INTEGER:70 to 170; 250(0.1dB); AInvalid:255 ETMA:92 to 100(0.25dB); Invalid:255

Y Y Y

ANT ANT ANT

TMA_NOISE

LINE_LOSS

FCE_BOARD

Tower Top Tower Top Amplifier Noise Amplifier Feeder Coefficient(0.1dB) Cable Loss(0.1dB)

FCE board type

INTEGER: 10 to 30

INTEGER: 0 to 80

FCE,FCEA,FCE4,FCE 5. valid when it is RSU

FCE5

NE_ID

GRU_NO

GW_CONFIG_MODE

CARRIER_GROUP

CARRIER_NUMBER

NE ID

GSM RU No.

GU Carrier Config Mode

Carrier Group

Total Carrier Number

INTEGER: 0 to 65535. should be unique in the whole subnetwork. Index of all sheets

RSU2 to 25, RRU: 51 4G+1U,2G+2U,INVALI to 74The second PA INTEGER: 0 to 32. DSingle radio mode of R8882RSU82 0:Do not group is INVALID. is:'RU No.#2'

DTR:1 to 6, TTR:1 to 2, RSU82:1 to 4, R8882: 1 to 6

95 95 95

2 4 6

Invalid Invalid Invalid

1 2 3

2 2 2

CARRIER_POWER_PARA STATIC_POWER_LEVEL

SECTOR_ID_1

TRX_NUMBER_1

SECTOR_ID_2

Carrier Power(W)

Carrier Static Power Level(db)

First Sector No.

Carrier Number dedicated to first sector

Second Sector No.

INTEGER: 1 to 80

0db,2db,4db,6db,8db,1 0db,12db,14db,16db,18 The Id should exist in db,20db. -0.2db,-0.4db,GSM Sector sheet, 0.6db,-0.8db,-1.0db,255:invalid 1.2db(only TTR and RSU02)

INTEGER: 1 to 6

Same as sector 1

20 20 20

0db 0db 0db

1 2 3

2 2 2

TRX_NUMBER_2

SECTOR_ID_3

TRX_NUMBER_3

SECTOR_ID_4

TRX_NUMBER_4

Carrier Number dedicated to second sector

Third Sector No.

Carrier Number dedicated to third sector

Carrier Number Fourth Sector No. dedicated to fourth sector

Same as sector 1

Same as sector 1

Same as sector 1

Same as sector 1

Same as sector 1

SECTOR_ID_5

TRX_NUMBER_5

SECTOR_ID_6

TRX_NUMBER_6

SUB_FREQ_BAND

Fifth Sector No.

Carrier Number dedicated to fifth sector

Sixth Sector No.

Carrier Number dedicated to sixth sector

Branch Frequence Band

Same as sector 1

Same as sector 1

Same as sector 1

Same as sector 1

INTEGER: 0 to 3. 0 or 255:invalid

255 255 255

NE_ID

SECTOR_ID

GPS_OFFSET

POINT1_RU_NO

POINT2_RU_NO

NE ID

Sector No.

GPS Synchronous High speed railway High speed railway Frame Header cell entry point 1 cell entry point 2 Offset RU No. RU No.
INTEGER: 0 to 50 Can be blank Can be blank

INTEGER: 0 to 65535. should be unique in the INTEGER: 1 to 24 whole subnetwork. Index of all sheets

95 95 95

1 2 3

0 0 0

NE_ID

SECTOR_ID

TRX_NO

CHANNEL_MODE ARRIER_NUMBER_OF_LOGIC_FREQ C

NE ID

Sector No.

Logic Carrier Frequency No.


INTEGER: 1 to 54

Channel Mode
SINGLE:Single channel, DUAL:Dualchannel, MULTI:Multichannel

Physical Carrier Number


INTEGER: 1 to 12

INTEGER: 0 to 65535. should be unique in the INTEGER: 1 to 24 whole subnetwork. Index of all sheets

95 95 95 95 95 95

1 1 2 2 3 3

1 2 1 2 1 2

SINGLE SINGLE SINGLE SINGLE SINGLE SINGLE

1 1 1 1 1 1

CARRIER_GROUP

FREQ_BAND

SUB_FREQ_BAND

USE_IRC

EXTENSION_CARRIER

Carrier Group

Frequency Band

Branch Frequence Band

Use IRC

Extension Carrier

INTEGER: 0 to 32. 0:Do not group

2.1G,1900M,1800M,85 INTEGER: 0 to 3. 0 or 0M,900M 255:invalid

0:Disable IRC,1:Enable Y:Yes, N:No IRC,2:Enable STIRC

1 1 2 2 3 3

900M(Band 900M(Band 900M(Band 900M(Band 900M(Band 900M(Band

VIII) 255 VIII) 255 VIII) 255 VIII) 255 VIII) 255 VIII) 255

1 1 1 1 1 1

N N N N N N

NE_ID

DRY_CONTACT_POSITION

DRY_CONTACT_NO

NE ID

Dry Contact Position

Dry Contact No.

INTEGER: 0 to 65535. should be unique in the whole subnetwork. Index of all sheets

SA,SE,FCE,FCE-II,FCEIII,FCEA,FCEA-II,FCE3,FCE5,FCE5II,FCE5-III. If position is RU, the pattern is RU-No., example:RU-51. For the FCE series, please refer to the help documentation.

The SA/SE board supports 8-way input, the number range is 0 to 7. FCE3 is 0 to 7, FCE5 is 0 to 6, FCE and FCEA is 0 to 4, R8880A-U2112 is 0 to 2, other RF board is 0 to 3.

95 95 95 95 95 95 95 95

SA SA SA SA SA SA SA SA

4 7 0 2 3 5 6 1

DRY_CONTACT_TYPE

DRY_CONTACT_CONTENT

ALARM_STATUS

Dry Contact Type

Dry Contact Alarm Code

Dry Contact Alarm Status

198092044:Cabinet door alarm,198092045:Flooding alarm,198092046:Smoke alarm,198092047:Infrared alarm,198092048:Air-condition fault,198092049:Surge Protection Input:Input dry contact, Output:Output Device fault,198092051:PSU dry contact. Output dry contact alarm,198092052:PSU fan should be linked to contact No.6 or 7 alarm,198092068:Base station of SA/SE. master power supply break alarm,198092206:Battery alarm,198092207:AC power-cut alarm,198092208:Rectifier model alarm,198092209:Thermoelectric cooling alarm,198092550 to 198092599:User Defined Alarm

Valid only if type is input. OPEN:Alarm appears if contact is open, CLOSE:Alarm appears if contact is closed

Input Input Input Input Input Input Input Input

198092554 198092557 198092550 198092552 198092553 198092555 198092556 198092551

CLOSE CLOSE CLOSE CLOSE CLOSE CLOSE CLOSE CLOSE

OUT_CONTACT_TYPE

Output Dry Contact Status

Valid only if type is output. 0:Output low level, 1:Output high level

0 0 0 0 0 0 0 0

Você também pode gostar