Você está na página 1de 10

Power Vision Getting Started Guide - 1

2191 Mendenhall Drive North Las Vegas, NV 89081


1-800-992-4993 www.dynojetpowervision.com
Power Vision
GETTING STARTED GUIDE
Parts List
1 Power Vision Unit
1 J1850 Cable
1 USB Cable
1 Software CD
1 Getting Started Guide
!!!---WARNING---!!!
FOR RACING VEHICLE USE ONLY
Note: This product is not for use on roads or vehicles subject to emission control requirements and is not legal for use or installation on motor vehicles operated on public highways in the State of California
or other States where similar emission and decibel regulation laws may apply. The user shall determine suitability of the product for his or her use. The user shall assume all risk and liability in violation of
regulations and any incurred nancial obligations due to vehicle inspections or emissions tests.
Power Vision Getting Started Guide - 2 98100014.02 www.dynojetpowervision.com

Determining Your Operating System
Windows XP
1 Right-click My Computer and select Properties.
2 Click the General tab.
For a 32-bit version operating system, Windows XP Professional Version
<Year> appears under System.
Use PowerVisionSoftwareInstaller_x32_xxxxx.msi for this installation.
For a 64-bit version operating system, Windows XP Professional x64
Version <Year> appears under system.
Use PowerVisionSoftwareInstaller_x64_xxxxx.msi for this installation.
Windows Vista
1 Right-click My Computer and select Properties.
2 Verify System Type.
Windows 7
1 Right-click My Computer and select Properties.
2 Verify System Type.
F
I
G
.

1
F
I
G
.

2
F
I
G
.

3
Power Vision Getting Started Guide - 3 98100014.02 www.dynojetpowervision.com

WinPV Software Installation
Use the following instructions to install the WinPV software on your computer.
It is strongly recommended that you exit all other Windows programs before running
this install program.
1 Insert the WinPV CD in your CD-ROM drive.
2 Double-click My Computer and browse to your CD/DVD Drive.
3 Double-click PowerVisionSoftwareInstaller_x32_xxxxx.msi for 32-bit
operating systems or PowerVisionSoftwareInstaller_x64_xxxxx.msi for
64-bit operating systems.
Or
Download the WinPV software from Dynojet.
4 Read the Welcome window and click Next to continue.
5 Carefully read the WinPV license agreement, check the accept box, and click
Next to continue.
To install WinPV, you must accept this agreement. If you do not, Setup will
close.
6 Carefully read the information provided in the Readme window and click Next
to continue.
7 Select a destination location for your WinPV software to be installed and click
Next to continue.
Dynojet recommends that you do not change the default destination folder.
8 Setup will automatically add program icons to the Start menu. You may type
a new folder name or select one from the Existing Folders list. Click Next to
continue.
9 Read the summary of your settings and click Install.
10 Click Finish to complete the installation.
11 Continue with the Power Vision Driver Installation.
F
I
G
.

4
F
I
G
.

5
F
I
G
.

6
Power Vision Getting Started Guide - 4 98100014.02 www.dynojetpowervision.com

Power Vision Driver Installation
1 Using the USB cable, connect the Dynojet Power Vision to your computer.
The Found New Hardware window will open.
2 Select Yes, this time only and click Next.
3 Select Install from a list or specific location and click Next.
4 Select Search for the best driver in these locations.
5 Verify the location points to your Power Vision folder in Program Files.
6 Click Next.
7 Click Finish to close the wizard.
8 Continue with Checking the WinPV Update Client.
F
I
G
.

7
F
I
G
.

8
F
I
G
.

9
Power Vision Getting Started Guide - 5 98100014.02 www.dynojetpowervision.com

Checking the WinPV Update Client
1 Using the USB cable, connect the Dynojet Power Vision to your computer.
2 Click Start on the Windows task bar and click All Programs.
3 Select PowerVision >PV Update Client.
4 Click Check For Updates. Select the following items to update:
PV Firmware
PV Tune Database
PV Software (Update Utility, WinPV, etc.)
Note: Make sure you select the correct operating version. Refer to Determining
Your Operating System on page 2.
5 Click Download & Install Selected Updates.
6 As the downloads are completed, click OK.
The Welcome to the Power Vision Software Setup Wizard window will appear.
7 Click Next to continue.
8 Carefully read the Power Vision software license agreement, check the accept
box, and click Next to continue.
To install the Power Vision software, you must accept this agreement. If you do
not, Setup will close.
The Power Vision Software Feature window will appear.
9 Click Next to continue. Dynojet recommends you do not make any changes to
this window.
Setup is ready to install the Power Vision Software.
10 Click Install to begin installation.
11 The Power Vision Software update is now complete. Click Finish to exit the
Setup Wizard.
For detailed software instructions and user information, refer to the Help
included in the software.
F
I
G
.

1
0
F
I
G
.

1
1
F
I
G
.

1
2
Power Vision Getting Started Guide - 6 98100014.02 Toll Free: 1-800-992-4993

Installing the Power Vision
1 Connect the Power Vision to the ECUs J1850 port.
2 Route the Power Vision cable away from any moving or hot parts.
Dynojet recommends using zip ties to secure the cable to existing non-moving
components.
3 The Power Vision module may be mounted to the bikes handlebars using
Techmount hardware.
Note: The Power Vision does not need to remain on the bike.
Figure 15 and Figure 16 are examples of the Power Vision module mounted to
a 2009 Night Rod using the Techmount bracket.
F
I
G
.

1
3
F
I
G
.

1
4
F
I
G
.

1
5
Power Vision Getting Started Guide - 7 98100014.02 www.dynojetpowervision.com
F
I
G
.

1
6
F
I
G
.

1
8

Saving Stock Calibration
Save Stock saves a copy of the stock calibration to the Power Vision module as
a backup. Save Stock must be completed before any editing can be done to the
parameters on the device or in the WinPV software.
Use the following steps to save the stock ECU calibration to the Power Vision
module.
1 Touch Vehicle Tools >Save Stock.
Figure 15 and Figure 16 are examples of the Power Vision module mounted to
a 2009 Night Rod using the Techmount bracket.
2 Touch Yes.
3 Touch OK when completed.
F
I
G
.

1
7
Power Vision Getting Started Guide - 8 98100014.02 www.dynojetpowervision.com

Loading a Stock File for Editing
The Power Vision accepts custom tune files created in WinPV and pre-loaded
Dynojet maps installed in the Power Vision memory from Dynojet Research. To
edit stock files, the Power Vision must be married to the ECU. Marrying the Power
Vision to the ECU locks the Power Vision module to that ECU and prevents a single
device from being used on multiple ECUs. You cannot unlock a Power Vision from
a married ECU. Once the marriage process is complete, you can open the stored
calibration in the WinPV software to edit all parameters or change Dynojet specific
functions on the device.
Use the following steps to load a copy of the stock tune file for editing.
Note: Once this process is complete, the Power Vision module will be married
to the ECU.
F
I
G
.

1
9
1 Touch Program Vehicle >Load
Tune.
2 Touch Load Copy of Stock.
This will load a copy of the stock
tune into the Tune Manager.
Once loaded into a slot, it will be
converted into a custom tune which
can be edited and/or flashed to the
ECU.
3 Touch OK.
5 Touch a slot to save the selected
tune file.
Note: If there is any data in the
selected slot, it will be
overwritten.
6 Touch OK.
A copy of the stock tune will be
saved.
7 Touch OK.
F
I
G
.

2
0
F
I
G
.

2
2
The Power Vision and the bike are
now married.
4 Touch OK.
The tune is now ready.
8 Touch Flash to flash this tune to the
ECU.
or
Touch Edit to edit this tune.
or
Touch Exit to exit the screen without
any changes.
F
I
G
.

2
1
F
I
G
.

2
3
Power Vision Getting Started Guide - 9 98100014.02 www.dynojetpowervision.com

F
I
G
.

2
4
Loading a Custom or Dynojet Tune File
The Power Vision accepts custom tune files created in WinPV and pre-loaded
Dynojet maps installed in the Power Vision memory from Dynojet Research.
Use the following steps to load a Dynojet map file to the ECU.
1 Touch Program Vehicle >Load Tune.
2 Select Dynojet Tune.
The Power Vision is now searching
for compatible tunes for the
connected ECU.
3 Touch OK.
7 Touch a slot to save the selected
tune file.
Note: If there is any data in the
selected slot, it will be
overwritten.
8 Touch OK.
A copy of the stock tune will be
saved.
F
I
G
.

2
5
F
I
G
.

2
8
4 Select a Dynojet Tune file to load.
5 Touch Select.
The tune is now ready.
9 Touch Flash to flash this tune to the
ECU.
or
Touch Edit to edit this tune.
or
Touch Exit to exit the screen
without any changes.
F
I
G
.

2
6
F
I
G
.

2
9
6 Verify the Tune information. If the
Tune information is correct, touch
Continue.
F
I
G
.

2
7
10 Touch OK.
11 Turn the ignition key off and wait ten
seconds.
12 Turn the ignition key back on.
F
I
G
.

3
0
Power Vision Getting Started Guide - 10 98100014.02 www.dynojetpowervision.com

Outline Key
Main Buttons
Action of User or Power Vision
Text that will be displayed on screen
PV or User determines somthing
* The term TUNE MANAGER is just
the built in sandbox oI where the Power
Vision has the 6 slots available to store
and load tunes Irom.
LOAD TUNE
DYNOJET CUSTOM STOCK
Displays a list of available
DYNOJET TUNES
List of any LOADED TUNES
Basically the Tune Manager
User selects any of the tunes that have
been either preloaded, loaded through
DYNOJET TUNES or STOCK TUNES
Select the type of tune to load into tune manager.
This will LOAD a copy of the STOCK tune into the TUNE
MANAGER. Once Loaded into a SLOT it will be
converted into a CUSTOM tune which can be EDITED
and or FLASHED to ECM No DYNOJET TUNES are
available for this bike
No Tunes have been loaded
into the Tune Manager,
Please LOAD Either a DYN-
OJET TUNES or a STOCK
TUNE
Returns to LOAD TUNE
Checks to see if Cus-
tom Tune is Editable
Returns to LOAD TUNE
Returns to Tuning menu
Select the Slot you would like to
Load the selected tune into
Description of
Selected Tune
User Selects Slot
User Selects Dynojet Tune
Select Parameter to Edit
Select Parameter to Edit
This tune is locked
and not editable
Select Slot to save to SAVE
a COPY of STOCK to:
User selects slot
The COPY of STOCK has
been successfully save.
User Selects Parameter
User Selects Parameter
User EDITS Parameter
User EDITS Parameter
User CONFIRMS EDIT
User CONFIRMS EDIT
User saves EDIT to tune
User saves EDIT to tune
Would you like to save this
EDIT to the tune?
Would you like to save this
EDIT to the tune?
(Parameter edit
no change from current)
(Parameter edit
no change from current)
Confirm
Confirm
Returns to EDIT or APPLY
Returns to EDIT or APPLY
Loads tune into chosen
slot in Tune Manager
Would you now like to EDIT or
Flash this tune to the ECU?
Would you now like to EDIT or
Flash this tune to the ECU?
CAUTION!!!
Any Data in this slot will be over-
written by the selected tune.
Flashes tune to ECU
Flashes tune to ECU
Turn off bike to set.
Turn off bike to set.
IF Yes
Slot 1 Slot 1 Slot 3 Slot 3 Slot 5 Slot 5 Slot 2 Slot 2 Slot 4 Slot 4 Slot 6 Slot 6
Cancel
Cancel
Cancel
Cancel
Cancel
Cancel
Cancel
Cancel
NO
NO
NO
NO
Select
Continue
Select
OK
OK
OK
Select
OK
OK
OK
YES
YES
IF Yes
EDIT
EDIT
SELECT
YES
YES
IF None IF None
FLASH
FLASH
EXIT
EXIT
CANCEL
Cancel
IF NOT

Você também pode gostar