Você está na página 1de 2

I NTE

RN

T ATIO EN NAL PAT

SPECIFICATION SHEET CARBON BOILER 75lt


TECHNICAL CHARACTERISTICS
The particular nature of the tank allows to have a big surface (bigger than a square metre) wrapped by a special heating element which, powered by the electric energy, reaches the temperature of 120C, bringing to 85C the temperature of the inner walls of the tank, increasing the thermal exchange with the water and, at the same time, it avoids the limestone formation.

FUNCTIONAL CHARACTERISTICS
The cold water that enters inside the tank from its lower part is directed towards the heated walls. Consequently we have a more rapid and effective exchange of temperature between walls and water. The consumption of electric energy is highly reduced and optimized thanks to the heater which is made up of carbon fibre cables (element that reduces of 40% the need of energy on equal reached temperature), and to the partialisation of the used power (400 - 1.200 Watt and 1.400 Watt with Plus function), all regulated by the electric exchange. The electric exchange, provided with display, is connected to two probes for the relief and control of the water temperature in the higher and lower part of the tank. It has the particular function of : set two time-slots of functioning per day (there is the possibility to benefit from the double-hourly rate) manage the build-up temperature to calibrate the electric consumptions following the precise hot water needs manage of the electric power

ADVANTAGES
The characteristics above described permit to the electric Thermal Technology Boiler to have: performances of hot water production incomparable with other similar products that uses electric resistance dipped into the water high energy saving and respect for the ambient economic, thanks to the modulation of the used power which is an essential requirement of the energy saving with the use of the optimal energy

OBTAINED PERFOMANCES
DT = 25C DT = 45C Maximum operating temperature Heat loss at 65C in 24 hours Drawn water quantity at 40C (incoming cold water at 15C)
Cycles of water drawing at 40C lasting 5 minutes (35 litres supplied for each cycle -7 litres/min:) with pauses of 15 minutes among every drawn (incoming water at15C) Cycles of water drawing at 40C lasting 7 min. (50 litres supplied for each cycle -7 litres/min:) with pauses of 15 minutes among every drawn (incoming water at 15C)

1 hour and 30 min. 2 hours and 50 min. 90C 1,40 kWh 140 lt. n. 7 cycles

consumption 1,56 kWh consumption 3,00 kWh

245 lt. supplied

n. 4 cycles

200 lt. supplied

www.thermaltt.com info@thermaltt.com

PRACTICAL ExAMPLE
The above described performances coupled with the presence of an electric exchange, permit to set the hot water quantity following your own needs. As example, following the number of the components, we foresee the following daily consumptions, calculating the supply at intervals and the restore of the water temperature set at 1 kWh = 0,18 4 persons 3 persons 2 persons 1 person temperature setting: 65C temperature setting: 60C temperature setting: 55C temperature setting: 45C supply 245lt. supply 190lt. supply 135lt. supply 90lt.
consumption 6,25 kWh consumption 5,15 kWh consumption 4,10 kWh consumption 2,45 kWh

equal to 1,13 equal to 0,93 equal to 0,74 equal to 0,45

The mural electric boiler Thermal Technology is designed and realized to assure the expectations of duration, of high production performances and low energy consumptions. The tank is made up of stainless steel with soldering with TIG and with Microplasma. Tank of stainless steel AISI 316L soldered with TIG technology and with Microplasmawith INTERNAL and EXTERNAL pickling treatment Protection device, composed by a replaceable magnesium anode, that protects from vacant currents and from corrosion Inspection flange for the tank (diam. 12 cm) Maximum working pressure 6 bar Hot cold water junctions 1/2 Insulation of high density polyurethane foam and of high thickness - 40 mm exempt from CFC and HCFC External mantel of sheet metal varnished with epoxy powders Upper and lower bottoms of antistatic and shock-proof ABS Display with the indication of the build-up water, operating powers, ON/OFF, time Thermostatic valve for the manual adjustment of the out-coming water temperature Safety valve (compulsory installation) Power 1400 W - 1200 W - 400W Net weight: 29 kg Protection IP 40

NOTES FOR THE INSTALLATION


it is suggested the installation of a device (expansion vessel) to compensate the increasing of heated water volume installation of a group for incoming pressure regulation it is suggested the installation of a system for the water treatment Code NTA_50LT NTA_75LT NTA_100LT NTA_VTERM Description Boiler 50 lt. Boiler 75 lt. Boiler 100 lt. Manual thermostatic valve

THERMAL TECHNOLOGy SRL - Via Montello, 67 - 31031 Caerano San Marco (TV) Italy Tel.: +39 0423 85 85 89 - Fax: +39 0423 19 90 110 - www.thermaltt.com info@thermaltt.com

Você também pode gostar