SKU02-07
The Start Menu ................................................................................................. 1 Building Project Administration...................................................................... 2 Data Organisation and Data Backup .............................................................. 4 Instant Help....................................................................................................... 5 The Screen Layout in the SEMA Program System ........................................ 7 Operational Concept in the SEMA Program .................................................. 8 The Drawing Administration in the SEMA Program ...................................... 11 Our example building project.......................................................................... 14 Ground Plan...................................................................................................... 15
Creating a Ground Plan......................................................................................................... 15 Ground Plan Dimensioning .................................................................................................. 16
Trimmings......................................................................................................... 38
Creating a Chimney Trimmer ............................................................................................... 38
For Your Construction Drawings: Dimensioned Drawings Auto Dimensioning Single Member Representation ........................................... 39
The F7 Display Settings ........................................................................................................ 40 Admeasure Lists.................................................................................................................... 41 Summary Calculation ............................................................................................................ 42 Material List............................................................................................................................ 43
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 8304 939-0 Fax +49 8304 939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
3D Walls and Construction Plane......................................................................................... 52 Roof Design ............................................................................................................................ 55 Ceiling Joist System........................................................................................................... 57 Stairs 59
Exercises........................................................................................................... 85
Creating an offer/quotation for a partial-hip roof ............................................................... 85 Strutting of the overhang purlin or a roof extension ......................................................... 86 Notes: ...................................................................................................................................... 87
SEMA GmbH Dorfmhlstrae 7-11 D-87499 Wildpoldsried Tel. (08304) 939-0 Fax (08304) 939-240 im Internet: http://www.sema-soft.de E-Mail: sema@sema-soft.de 2006 by SEMA GmbH.
START MENU
When you start the SEMA program, the start menu will give you fast and easy access to the program. Select one of the five items with the left mouse button ( Here is a brief summary of the menu items: Last Project Opens the building project you last worked at. If no building project has been filed yet, e.g. when you start the program for the first time, the menu item "Last Project " is not active! New Project Select Project Example Projects Whats new? Here you can create a new building project. Displays the Building Project Administration so that you can select a project from the list. Shows a list of example projects in the Building Project Administration. Opens the Release History that describes all new features of the current version. ).
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
BPs in
Selecting the path: you get a list of all paths used last and by clicking Via one, it is adopted into the path field. With you can change the building project path.
File:
Displays the file name under which the active building project is listed. Preview picture of the selected building project you can individually define preview pictures under EDIT "Create BP preview. The look of the header frame depends on the user settings under OPTIONS New Project or Properties.
Project Preview:
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
When you choose the standard installation, the program is automatically installed under the installation directory shown above. However, if you click on Browse... you can select another installation directory. Every new version is installed under ist own program folder.
Under the standard installation, all the building projects are saved under the project path shown above. Via you can also choose other project paths. All building project that have SEM in the first column are compressed. When the building project is called up, they are automatically unpacked. If you want to create annual back-up files of your project data, it is better to first compress the data and then archive it e.g. with the Explorer under the relevant year on a network or CD.
The SEMA Work Master Data are by default installed under the following path: C:\Programs\SEMA\SEMAV95D\Profiles\E_PLATZ\Eigenest. Via the Export master folder you can save the individually adapted Work Master Data on a network or a CD.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
Instant Help
Screen Menu and Brief Summary
INSTANT HELP
Introduction:
In order to help you with question & problems about our programs in a fast and easy way without studying extensive manuals, we included an Instant Help feature in our programs. This context-sensitive Help feature is completely integrated into the SEMA system, so that using and working with the program becomes even more simple, faster and efficient. We have concentrated only on the most important aspects and illustrated them with many screenshots and technical illustrations so that you find everything you need at a glance. The following short introduction is to give you an overview of how it works and shows you all the possibilities this valuable tool offers.
System Requirements
To be able to use the integrated Instant Help you need the Internet Explorer for Windows version 6.x or higher.
Getting Help
If you run into problems and dont know what to do simply press the F1 key and get help on the specific item/command you are currently working with.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Screen Menu and Brief Summary After you clicked the Help symbol, the drawing area (white area on your screen) is normally divided into two areas in the left area a help window will open which contains the information about the active command. In some cases (Display Options, Presettings etc.) more room is needed and then a completely new window, outside the program, will open and provide the information. However, with Alt+tab (=switch task) you can conveniently switch between the software and the help window. The functionality of this separate window is exactly the same as of the integrated help. Blue & underlined texts indicate that there is a link to further information. Just click with your mouse on such a link to get to this additional information. To make our Instant Help compact and easy to use, we have integrated many linked buttons or graphics. If you move your mouse pointer over such a button/graphic, the mouse pointer changes into a hand and thus indicates that there is a link. This technology has for example been used for the additional options of the creation commands (see illustration on the left). If no feature or command is active or if no suitable help topic exists, the general Help for the program will appear. For navigating through the Instant Help Goes back to the previous Help topic For navigating through the Instant Help Goes forward to the next Help topic Prints out the currently displayed Help topic Takes you to further informationen about your program version, e.g. Release History or Highlights of this version Shows the contents of the SEMA CD (in a separate window) Opens the general Help for the program; here you find general information about using the program Opens the context-sensitive Help for the program; here you can get an overview of the specific help topic for all parts ot the program Search feature for the SEMA Instant Help Closes Instant Help
INSTANT HELP
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
drawing area
SCREEN LAYOUT
Screen layout once you have selected a part of the program: 1. Creation commands 2. Status commands for this part of the program 3. Editing commands 4. Icons for the CAD, Dimensioning, MCAD and 3CAD modules
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Screen layout of the different parts of the program, example Ground plan
Shows the active part of the program By clicking this button, you can go back to the program selection. Creation commands Same structure for other parts of the program.
OPERATIONAL CONCEPT
Status switch Displays/Changes between line style, line width and hatch.
Editing commands They are the same for ALL parts of the program Only minor, module-specific differences in the subcommands
CAD / DIM / MCAD / 3CAD Via these icons you can access these parts of the program Layer display/Layer switch = click with left mouse button Mouse symbols used in the course materials = hold down left mouse button = click with right mouse button = hold down right mouse button
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
SEMA Basic Course Control Commands in the Top Toolbar The following control commands make your work with program faster and easier. / Screen Refresh / Minimize
Updates your drawing and displays it in its updated form (screen refresh). To minimize your drawing, click the icon and then click the drawing area and hold the left mouse button down ( ). The border of the drawing area (and so the drawing) will be reduced in size.
/ Maximize
To maximize your drawing, click the icon and then click the drawing area and hold the left mouse button down ( ). The border of the drawing area (and so the drawing) will be enlarged.
Goes back the last three zoom steps. Displays entire drawing centered in the drawing area. Activates the magnifier to enlarge a certain part of the drawing. Alternatively, you can also use the Alt combination. + key
OPERATIONAL CONCEPT
/ Magnifier
/ Shift
Lets you move the drawing around. Alternatively, you can also use the Alt + nation. key combi-
CTRL +
Visibility Buttons in the Input Box All other buttons are explained in a specific context in the course materials. After one component has been marked, you can use this button to mark all components of the same type at once. Undoes the last visibility activation. Restores the undone visibility activation. Blinds out all marked components. Blinds out all unmarked components, only the marked components remain visible. If there are several stairs in a BP, you can blind out all unmarked stairs and only the marked stair (stairs handle has to be marked) remains visible. If there are several stairs in a BP, you can blind out the marked stair (stairs handle has to be marked). Makes all blinded out components visible again.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Highlighting of Drawing Elements When you move with the mouse to a component (object), the component/area is highlighted in colour (standard: yellow). Thus it is very clear which component exactly you are pointing at. You can change the colour under the Colour Settings.
When you hold down the Shift key while marking, you can get to all components and areas, this is very helpful if two rafters are very close to each other but you want to mark the area behind them.
OPERATIONAL CONCEPT
If there are several components within the snap radius of the mouse, you will see an empty bracket "() with the Hint text of the first component, e.g. () Rafters. If you click the left mouse button, you will mark this component, however, if you wait a moment, the number of components within the snap radius will appear, e.g. "(4) Rafters. If you now click the left mouse button, a window with a list of all components within the snap radius is displayed. Note: To get straigth to this window with the list, click the right mouse button.
Marking Statuses: All components can be marked All components in the currently active program module can be marked All CAD layers can be marked Only the currently active layer can be marked Marking several components: By drawing a frame over the components with By drawing a line over the components with
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
11
Ground Plan Here you can organize/edit different project alternatives, construction stages etc. of one project.
DRAWING ADMINISTRATION
Storeys Here you can organize/edit different storeys of a project (buttons on the right) and define their height levels or visibilities.
Walls Here you can organize/edit all walls or construction planes of a project. The next tab Elements for roof and ceiling elements offers the same functionality.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Input Mask
3D Here you can organize/edit different 3D representations or 3D sections (vertical or horizontal) of a project.
Profiles/Dormers
DRAWING ADMINISTRATION
Here you can organize all roof areas and dormer profiles of a project.
Images Here you can organize/edit all images (= 2D copies of drawing elements) of a project.
Plans Here you can organize/edit all plan templates used for a drawing.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
13
Input Mask
Plans Via the NEW button, additional plan templates e.g. for building permit plans can be laoded. The plan templates contain all the relevant information about page format, drawing legend etc.
DRAWING ADMINISTRATION
Lists Here you can organize/edit all material lists that have been generated for the project. These contain, depending on the module, e.g. timber lists, single member lists etc.
Calculation Here you can organize/edit all admeasure lists and calculation data that have been generated for the project.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Part 2 Example
Our example building project
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
15
Ground Plan
Creating a Ground Plan
Command and Brief Summary Input Mask Creation of a ground plan with the Input Option 2 for dimensions see drawing below. The end point of the last line is automatically snapped with . When closing the transverse part, the length of the line can be determined by snapping an already existing reference point in the drawing.
Same menu structure in CAD with only minor differences Available input options:
Enter the width of the house wall. The program automatically suggests 0.365 which you can accept with or change with the .
Options available for creating: To enter an offset dimension which indicates by how much the line will be displaced. / To draw a house wall with 1 line or 2 lines (double line). To undo the last line. The line/double line created last will be deleted. If you do not want to close the line (polyline), you can use this command to accept the house wall as it is (not closed).
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Creation commands
For the manual creation of the dimension lines for the exterior building dimensions use Input Option 5:
For the manual creation of diagonal dimension lines use Input Option 1:
Sub-command for marking out additional dimension points on the dimension lines created before.
In the Master Data for dimensioning you can individually adapt the look of the dimensioning lines/data.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
17
Profile Assistant
Creating a Profile
Explanation of the Profile Assistant with the example of a main roof profile. Command and Brief Summary Program selection menu Input Mask
You can either choose "Profile normal (with counter profile)" or "Pitched roof profile". Then enter a name for the profile (in our example: "MR area") and by clicking "Start" the roof assistant is opened.
Creating a PROFILE
The following settings have to be made step by step in the roof assistant.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Input Mask
"Battens tab:
Data: from template Template: BRAAS
I.e. the program uses the "Braas tiles" data record from the master data group "Boarding
Creating a PROFILE
The values for eaves and ridge height will change because of the following inputs of cross-sections and eaves purlin offset.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
19
Input Mask
"Rafter tab: To determine a rafter, e.g. 08-18 or to change width and height accordingly. For all the other information (e.g. eaves & ridge design) see illustration.
Creating a PROFILE
"Base/Ri" (base/eaves purlin/ridge purlin) tab: For the necessary changes, see illustration on the right.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Command and Brief Summary "Center P" (center/middle purlin) tab: Center/middle purlin 1: 16-22 with LMT via timber grade of the ML tab (you can access the autotext with in the respective input field).
Input Mask
Creating a PROFILE
"Tie Beam tab: For the necessary data, see screen-shot on the right. The position of the tie beam with reference to the reference purlin of the rafter has to be determined in the master data record of tie beams:
The center-purlin tie beam is defined as below, position left The ridge tie beam is notched out 2 cm and applied on both sides The tie beam shortening dimension is 1 cm
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
21
Input Mask
Result
To switch between profile and double profile view To switch the automatic dimensioning off -> -> Automatic joining dimensioning on
Creating a PROFILE
Icons that determine the look/design of the profile drawing. -> -> Automatic bricklayer dimensioning on
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Creating a PROFILE
Tabs in the profile image Under the different tab you can find very helpful information, such as
Struct/Batt: shows the roof structure and the spacing of the battens
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
23
Input Mask
New profiles created in a building project are by default saved under this project ONLY.
Creating a PROFILE
To create a new profile To copy an existing profile To get profiles from the working master data To get profiles from the SEMA master data To save a profile in the working master data The icons in the top task bar of the Profile Management. To save changes of a profile To delete a profile To save the profile as a template To edit the profile with the assistant If you click on the Print profile drawing icon, the profile is automatically dimensioned for joining. Then you can continue as normal, i.e. click the printer icon, select the scale and start printing.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Command and Brief Summary The following profiles are required for the roof design: Battens:
Input Mask
What we have:
Pitch + TL eaves purlin Basic dimension: 5,00m Roof pitch: 35 Overhang length ca. 0,80m Top level eaves purlin 0,80m Rafter: 08-18 Jamb wall: 0,365 Eaves purlin: 16-16 Birds mouth: 0,03m Eaves purlin offset: 0,13m Ridge purlin: 16-20 Birds moth: 0,03m Center purlin 1: 16-22 BSH Position: BL: 2,76m Birds mouth: 0,03m Center tie beam 1: 8-16 under purlin, purlin 1 / position left Ridge tie: 4-12 ridge tie, 2cm notched out / Position on both sides
Creating a PROFILE
Copy P1 main roof, rename it and then edit it with the assistant as follows: P2 Transverse roof (TR area) Battens:
Adapt battens
What we have:
Overhang + pitch + TL eaves purlin Basic dimension: 4,00m Center purlin 1: delete Center tie 1: delete Ridge tie: delete
Copy P2 transverse roof, rename it and then edit it with the assistant as follows: P3 Partial hip roof (PH area) Battens:
Ignore battens
What we have:
Eaves height + overhang + pitch Eaves height: 2,00m Ridge height: 3,693m
Copy P1 main roof, rename it and then edit it with the assistant as follows: Battens: P4 Main hip roof (HR area)
Disregard battens
What we have:
Eaves height + overhang + pitch Ridge height: 4,393 m Roof pitch 50 Play rafter/jamb wall: 0,01 m Center purlin 1: delete Center tie 1: delete Ridge tie: delete
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
25
Roof Design
Command and Brief Summary Program selection menu Creation command To enter the partial roof, Input Option 1 is used: Input Mask
Points
1-2 2-3 3-4 4-5 5-6 6-7 7-8 8-1
Profile
P1: main roof profile P4: hip roof profile P1: main roof profile P2: transverse roof profile P3: partial hip roof profile P2: transverse roof profile P1: main roof profile Barge with 1m
When you create a roof design with Roof detail free always proceed counterclockwise and make sure you select the correct profile data for each roof area.
Result in 3D
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Rafter System
Placing Rafters
Command and Brief Summary Program selection menu Creation command Input Mask
Option
Placing fixed rafters If there is no reference ! line, it will be Select the roof area where you want to create the rafter with auotmatically created at the . selected roof area when you place the first rafter. Select the reference point for placing the rafter. Then determine the distance of the rafter to the reference point (10 cm). Determine the position of the rafter: Possibilities:
Left
Center
Right
Place another fixed rafter 2 cm left of the outer edge of the house wall.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
27
Option
Spacing the area If there are already rafters in a roof area (as here in the ! Select the roof area or part of roof area in which you example), the area between the . want to space the rafters with rafters or between rafter and roof edge (depending where you Determine the number of elements for the selected spacing clicked the roof area) is area. The Offset (or interspace) shows the resulting determined as spacing area. distance between the elements. Or, if an interspace has been set (pre-settings ALT+F7), the program suggest a number of elements.
For our example: determine the interspace/offset between the elements, the program then calulates the resulting number of elements. When you set an interspace, the program calculates the required number of rafters plus, if necessary, an equalization interspace at the beginning and/or end of the spacing area.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Mirroring the reference line To get the same rafter spacing on the opposite roof area (area 2), the rafter spacing created before has to be mirrored onto area 2.
Then click the opposite roof area (area 2). Now enter the distance from the reference line or confirm the suggested value with .
Spacing the remaining roof area You can do that in the same way as described above. For the hip roof area, select an even number of rafters to avoid a center jack rafter. And for the partial hip ! roof, select an uneven number of rafters to get a center jack rafter.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
29
Option
The calculated element height (on the basis of the jack rafter cut length) can be rounded and additionally be given an extra allowance To shift the base if you have different roof pitches, the following options are available:
For the form/design on the top side, the following options are available: For the form/design on the bottom side, the following options are available: For the eaves ends, the following options are available:
After you have clicked the option, a master data window will open at the bottom right corner of the screen where you can make different settings such as component width, ridge and eaves cuts and clippings for example. After you confirmed the master data with OK, you can click the roof edge. Then confirm the element height and the elements is placed and the jack rafters cut back. For the partial hip roof you have to switch the master data record. It is not necessary to create a hip or valley rafter in the profile program! The correct type of edge for the roof lines is automatically determined by the program.
Entering further hip/valley rafters In the same way as described above or with the manual input option.
The rafters are automatically shortened by the component width of the new elements.
The end type Plumb cut has to be assigned to the eaves of the two hip rafters of the partial hip roof.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Reading-in Purlins
Command and Brief Summary Creation command Input Mask
Option Prerequisite:
Profiles with purlins have been created with the Profile program The roof design and the rafter system have been created with these profiles
purlins for this roof area are created To mark several roof areas, use + and then the purlins for
these roof areas are created By pressing the spacebar, all roof areas of this storey are marked then confirm with and the purlins for these roof areas are created
The individual purlins can be subsequently edited manually at their corner points. By default, the purlins are scarfed at their panel point at 50% of their height. Purlins that are not not needed can be deleted.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
31
Input Mask
Reading-in of tie beams that have been defined in the Profile program.
Reading-in tie beams for the partial roof 1 The following possibilities are available:
Click a rafter with the left mouse button ( ) the tie beam is then
created at this rafter To mark several rafters that are not next to each other, use + -
the tie beams are then created at these rafters To mark several rafters that are next to each other, use line marking ( ) - the
Under Read-in: you have the choice to either read-in all tie beams at once or to read-in the center and ridge tie separately. To determine the Position: of the tie beam, i.e. left, in the center, right or on both sides of the rafter; make you selection with the spacebar.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Input Mask
Option
For the different possibilities to mark the rafter, see previous page (partial roof 1). The height position of the tie system in the transverse roof can be adopted from the drawing (by clicking the tie beams of the main roof) into the input box.
Editing the tie system To edit the tie beams, we recommend to switch off (invisible) all other components of the rafter system. First, mark a tie beam with the left mouse button, then press the spacebar to mark all other tie beams. With you make only the marked components visible. After you finished the editing, you can switch back on all other components with .
Mark the tie beams you want to edit and then use the editing command Cut 1x. Select the first tie beam of the transverse roof as target edge. The end type is described in the master data on the left; here you also have the option to mark the connecting component.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
33
Dormer Assistant
Creating Dormers
Explanation of the Dormer Assistant with the example of a saddle-roof dormer. Command and Brief Summary Program selection menu Input Mask
To create a saddle-roof dormer, select it from the list and then edit it via
Creating a DORMER
Icons that determine the look/design of the profile drawing. They are the same as for profiles (see page 21)
The Assistant opens: Now follow the description below step by step. First, select the area where you want to create the saddle-roof dormer. The selected roof profile will appear.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Input Mask
I.e. the program uses the "Braas tiles" data record from the master data group "Boarding
Creating a DORMER
"Dormer tab: Roof overhang lengths has to be adapted to the fixed battens. With the Distance from OE jamb wall definition, the dormer can be positioned flush with the outer edge of the eaves purlin. Further options/definitions:
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
35
Input Mask
"Purlin tab: In our example, all crosssections of the purlins have to be changed to 16 x 16. All other settings can be adopted. For the intersection options between purlin and valley plank, see illustration on the right.
Creating a DORMER
"Members tab: For our example, delete the sole plate and change the crosssections of all other components to 16 x 16. Then adopt all other settings. For the intersection of the bottom edge of the dormer post, the following options are available:
For the intersection of the dormer with the main roof, the options are:
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Input Mask
Creating a DORMER
Front view: View of the dormer at right angles to the ridge Tabs in the dormer image The tabs offer helpful information such as.... Plank: Dimensioned drawing of the valley plank
Roof battens/Structure: Here you can see the roof structure and the spacing of the battens.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
37
Inserting Dormers
How to insert the saddle-roof dormer you have just created/filed in the rafter system. Command and Brief Summary Program selection menu Creation command Input Mask
Option
Inserting dormers
Creating a DORMER
For Roof area: click the roof area 1 or any rafter of this roof area with the left mouse button ( )
For Reference point: click the appropriate point with the left mouse button ( )
Confirm both Distance: 0,000 and Position: right with Enter 0,400 under Excess end barge: and then confirm with Confirm Clearance height: with and switch the last field End joint: with the spacebar to without tenon and the confirm with Barge projection (= projection of the boarding over the barge rafter of the dormer): 0,1 m
You can file as many dormers as you like in the master data. The dormer library works across all building projects. Each dormer has a handle and can thus very easy and fast be shifted, copied, edited or even deleted.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Trimmings
Creating a Chimney Trimmer
Command and Brief Summary Ground Plan modul Enter the chimeny position with Rectangle. You determine the starting point of the rectangle by pressing the spacebar twice before defining the starting point with a mouse click. Input Mask Use the 2. Input Option, for the dimension see drawing.
Options
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
39
For Your Construction Drawings: Dimensioned Drawings Auto Dimensioning Single Member Representation
You can dimension a sectional view for carpenters and bricklayers in Vertical Section with the Auto dimensioning feature. Command and Brief Summary Input Mask
How to proceed: Select the feature under Vertical Section. Then select the creation command Auto dimensioning and, if necessary, change in the master data window to the Section Joining and confirm with OK. To start the automatic dimensioning, click the button in the input line.
You can always manually edit and add to the automatically created dimensioning. Automatic dimensioning can always be edited (new calculation, delete) via the BEM handle.
CONSTRUCTION DRAWING
Save the vertical section via 3D Section: Click the icon and enter a name for the section (e.g. Section A-A) and it is Saving and opening a 3D automatically filed in the Drawing Administration. By clicking section you close the section. You can later access the section either via the Drawing in the top task bar. Administration or with
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Display Settings The menu is the same as for the creation commands. For each component, the componentspecific joining dimensions can be automatically displayed or hidden.
CONSTRUCTION DRAWING
Display of the rafter length At every rafter the length and the tracing angle are displayed. To give you a better overview, you can hide other components or entire component groups.
Saving and loading the display settings With the Load/Save display settings option you can save company-specific display setting and then use them for all your projects.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
41
Admeasure Lists
With Admeasure Lists you can create complete area and line admeasures directly out of the Roof Design. Command and Brief Summary Input Mask
CONSTRUCTION DRAWING
The menu for the data transfer Here you can select the required admeasure lists and then start the transfer with OK.
Admeasure list The list is auotmatically filed in the Drawing Administration under Calculation from where you can also open it. The calculation principles for the admeasure list can be pre-set under ALT+F7.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Summary Calculation
With the summary calculation you can carry out a complete quantity calculation with the construction data. Command and Brief Summary Input Mask
CONSTRUCTION DRAWING
The menu fot the data transfer Here you can select the calculation list (in the example Offer Saddle Roof) and then start it with Open.
Calculation list The list is automatically filed in the Drawing Administration under Calculation from where you can also open it. For further information about adapting the calculation list, please see the Advanced Course.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
43
Material List
To compile a material list, first all components and surface areas have to be transferred to Material List. Command and Brief Summary Input Mask
CONSTRUCTION DRAWING
The menu for the data transfer Here you can select which components you want to transfer. After you have clicked button, the the
program will start the transfer and as soon as the transfer has been completed, you can switch via to the material list. Material and Timber Lists All components from the construction drawings are listed in the material list. Further selection and grouping features for the material list are ecplained in the Advanced Course.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
ALT+F7 Presets
With these presets you can determine general settings for specific program features and also determine the look/design of the SEMA programs. Command and Brief Summary Program selection menu Input Mask You can access these pre-settings either via the keyboard or via the button in the top task bar. with ALT+
The pre-settings With these setting menus you make settings that apply to all modules, but can also create module-specific settings.
PRESETS
Saving and loading presets With the Load/Save presettings option you can save the different settings and then use them for all your projects
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
45
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Creating a Rectangle
As an alternative way of entering a ground plan. Command and Brief Summary Input Example(s) Creating a ground plan by using the 2. Input Option for dimensions see drawing.
Same menu structure in CAD with only minor differences. Input with 2. Input Option for dimension see drawing.
The lines not needed for the ground plan are edited (deleted) later on with the editing commands. You can use the House wall sub-command here in the same way as Line in the previous example. You can determine the starting point of the second rectangle by pressing the spacebar once before you define the starting point with a mouse click. Input with 2. Input Option for dimension see drawing.
The chimney position is entered via a rectangle. How to create the chimney trimmer is explained later on. You can determine the starting point of the chimney by pressing the spacebar twice before you define the starting point with a mouse click.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
47
Creating a Point
Command and Brief Summary Input Example(s) Place the first point on the inner house wall line at a distance of 10 m (Input Option 3). Then place the second point 2 m on the right and 3 m up (Input Option 3).
The reference points of the example above can also be used for this example. Reference point 1: radius 7m Reference point 2: radius 5m Select one of the two resulting points of intersection with the spacebar and then confirm with .
Useful option for not right-angled ground plans. Same menu structure in CAD. Possible input options:
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Creating a Polygon
Command and Brief Summary Input Example(s) Determination of the surface area on the bottom edge of the tie system.
Reference points of the tie beam bottom edge can be snapped with SHIFT + . Creation of a hatch polygon on a transverse roof area with the Input Option 1: Calculate the east elevation with hidden lines in 3D and then save it under the name East elevation.
In CAD the Box feature creates a rectangular polygon. Possible input options:
Polygons can be filled with hatch styles and textures. All roof, ceiling and wall surface areas normally offer polygon functionalities and can be edited accordingly. They are, however, generated via the module-specific creation commands. With F7 you can display the lengths and the polygon data (circumfence and area) for ground plan polygons. For CAD polygons there are no F7 display options for lengths, circumfence and area. These values can only be displayed for CAD polygons via the check icon.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
49
1. Option
Full circle via center point and radius Circular arc with starting and end angle Circular arc via 3 points Circular arc via 2 points and the radius
2. Option Not available Ground Plan! Possible input options: under 3. Option 4. Option
1. Option 2. Option 3. Option 4. Option Not available Ground Plan! Possible input options: under 5. Option
Ellipse via two points Ellipse via width and height Ellipse via angle, width and height Ellipse via angle 1 and width and angle 2 and height To move the ellipse just created to different positions in the drawing To move the ellipse just created to different positions in the drawing, parallel to a line and with a defined distance.
6. Option
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
SEMA Software
SEMA Software
SEMA Software
SEMA Software
under
When you enter a longer text (multiline), this Editor window is opened after you have selected the master data and the insertion point. Now you can enter your text or import extraneous files (e.g. Word files).
With the @ feature, you can position different placeholders and variables from the program as text in your drawing which is very useful for the drawing legend.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
51
To start off with, we have two non-parallel lines. The starting point is determined with 1x spacebar plus the arithmetical functionality for length input (to determine the angle, snap the end point of the first line and then divide the resulting length value by 2). The right angle on the target line is indicated via the mouse pointer and can be snapped with
Creating a ground plan with a diagonal annex without auxiliary line. Enter the ground plan line with the 2. Input Option (either with the keyboard or with the mosue):
0 - 12m 90 - 10m 180 - 8m 135 - 1,5m (angle grid) 225 - length? 1 x spacebar + horizontal setting-out with right mouse button on first starting point 2x spacebar + lenghten by 1.5 m 315 - length? 1 x spacebar + horizontal settingout with right mouse button on first starting point Switch to Input Option 1 and close outer contour.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Resulting 3D drawing
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
53
Input options In our example, we want to create a construction plane parallel to the ground plan edge, looking into the building.
construction
Creating COMPONENTS
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Input Mask
Working with CUT Creating REFERENCE LINES Creating COMPONENTS Creating TRIMMERS
Place corner posts with and then space the area with with the Post master data from the Framework group. Create window trimmers with You can determine the starting point of the trimming with 2x spacebar + mouse click.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
55
Roof Design
Creation of a Roof Design with the Rectangle Command
Command and Brief Summary Program selection menu Main roof Create the main roof with the Saddle roof sub-command and the MR profile master data with: Input Option 2: Width: 16m Height: 10m Barge: confirm Input Mask
Hip area Mark the right barge line by clicking BRG and then click Modify. Switch the type of roof area from Barge to Pulrin roof and then select the previously created hip roof profile P4 with and then confirm with
If the hip roof area is created after the intersection between main and transverse roof by modifying the partial roof 1, PR1 is calculated anew and the valley intersection with the transverse part of the building has to be executed again.
Transverse roof Create the transverse roof with the Transverse roof subcommand and the TR profile master data with: Input Option 1: Reference points from the ground plan Design: Valley Barge: confirm
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Input Mask
Partial hip roof Mark the right barge line by clicking BRG and then Modify. Switch the type of roof area from Barge to Purlin roof and then select the previously created partial hip roof profile P3 with and then confirm with
Resulting 3D image
The Hip roof sub-command works the same as the Saddle roof sub-command and generates immediately a partial roof with 4 identical roof areas via the Rectangle option.
In the same way: Creating a saddle roof with the line command Roof detail free. Enter a barge projection of 3 m on the left.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
57
For the second ceiling plate you have to set up a separate storey!
Use the Input Option 1, the existing ground plan and the master data Ceiling 22.
Possible input options: The transverse part of the building will be added later on see editing commands.
The ceiling cutouts for the chimney and stairwell can be either created via Box (=Rectangle) or Freeform (=Line).
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Working with LINE Working with REFERENCE LINE Working with RECTANGLE
Create the reference line the same way as in the rafter system. Create also the header beam the same way as in the rafter system. Spacing is also the same as in the rafter system. Creating the trimmers for the chimney and the stairs
stairs
chimney
Input Option 1
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
59
Stairs
Creating -spiralled Stairs with the Line Functionality
Command and Brief Summary Creating a new ground floor for the stairs Input Example(s)
Use Input Option 1 and the stairs master data LSTEP 120. After the contour of the stairs has been placed in the stairwell, start the calculation of the stairs with (in the bottom right).
Same functionality as that of the ground plan line. Possible input options:
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Editing Commands
General Information
For the following examples, you can use the roof areas and components we have already created as part of this course. Command and Brief Summary Editing command Input Example(s) Generally speaking, for each editing command there are certain options (functionalities) available, depending on the module. For our following general explanation we use the Cut command. Example: To go from Cut Lengthen/Shorten, first of all select the editing command (Cut). A list with all possible options opens from where you can select the required action.
Input line:
The input mask in the input area changes to the new option.
The program automatically places the reference point at the end of the longest marked component.
On the left you see the additional information that will be displayed when you move the reference point. Entering an angle You can enter an angle either with the negative values) or with in the drawing area. (positive and
Changing the reference side With the spacebar you can switch between internal and external angle.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
61
Input options under Cut for the Ground Plan and CAD module
Cut 1x Cutting of a ground plan line at the interior side (edge) of the outer wall.
Lengthen/Shorten Shortening of a ground plan line to half the length of the outer wall. Shift the reference point with .
Corner joints Add to the ground plan line with Line parallel.
Horizontal 2 x, with input option 5 (same length as reference line) Vertical 1 x, with input option 6 (variable length vs. reference line) Intersect both walls with Cut Corner joint
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Input Example(s)
Cutting of areas Example: dormer with negative pitch over a pitched roof.
Enter the dormer roof, approx. at the
center of the roof area from right to left (house width: 2m) and start calculation. Intersect the pitched roof are with partial roof 1 with Valley
Cut 1x Cut the rafter plumb to the outer edge of the eaves purlin
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
63
Input Example(s)
Cut 2x Cut the intermediate jack rafter at the meeting point (hip ridge) of the two hip rafters twice.
Lengthen/Shorten Lenghten the purlin so that it reaches over the outer edge of the rafter.
Cut TL/BL Cut the rafter at the bottom level of the tie beam.
Bevel This editing options is mainly used for 3D editing. Bevel a rafter to the outer edge of the eaves purlin with a double cut.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Input Example(s)
Input options for the Joist System and Wall Members modules
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
65
to length With this option you can post-edit the ground plan with:
Delete line (transverse part) Abut line to length Cut corner joint
Under Input Option 1 Shift Pan To modify the course of the eaves by inserting a point.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Input Example(s)
either on the top edge, the axis or the bottom edge The abutting point for inclined components can either be in plumb or following the pitch Butt joints are available only for components
Input options for the Joist System and Wall Members modules
at length For components at the same height, no unnecessary queries have to be answered
Snap the point of intersection between the wall and the ceiling beam with and then enter wall thickness as distance Further editing with Cut for play Shorten
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
67
Box and Freeform How to use it for the hatched north elevation in 3D with hidden line mode:
Hatch the roof area with Box Punch out the hip with a turned Box Punch out the transverse part with Freeform
Move the reference point from the ridge by pressing the spacebar twice and then do the punching.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Input Example(s)
Box
Here, Box has been used to create a cutout for the the ridge purlin in wall view.
Box Here, the Box option is used to post-edit a string end at the top.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
69
command.
Move the reference point from the ridge left house corner by pressing the spacebar twice and then do the adding.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Input Example(s)
Box You can create different floor heights in a storey with Box.
Box You can also create a transverse building part in the existing ceiling plate with Box.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
71
Extended options in the CAD and Ground Plan module Serial Copy
This edition command is NOT available for the Roof Design module.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Input Example(s)
Copying of a purlin (the same for tie beams and posts) in the overhang area. Then Cut at both ends.
Input options for the Joist System and Wall Members modules
Copying several marked ceiling beams. This option is also available for wall members.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
73
Mirroring of one or several lines or ground plan points at a horizontal, vertical or diagonal axis. Determine the mirroring direction for the marked object(s) with the mouse pointer ( ). Determine the distance to the original. After mirroring, close the option with .
Additional options:
-> Keep original -> Delete original
This editing command is NOT available for surface areas in the Roof Design and 3D Wall & Ceiling module. Mirroring in the Rafter System (mirroring of reference lines) is addressed in the next example.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Additional options:
Editing Commands - POSITION
With F6 you can freely determine the reference line for the angle.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
75
Input Example(s)
Additional options:
.Input
All other values of the flight elements can simply be confirmed with and do not need to be changed.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Input option that works in all modules for all marked components
You can also delete components with the After you have clicked the Delete button (or always the additional query: with . ) there is
When you mark several components of different types, the following dialog box with the drop-down menu appears at the bottom right of the screen. With this list you can either select only a specific group of components or all marked components. You can only select one component group out of the list. After you made your decision there is first the security check before deletion is carried out.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
77
For ground plan lines the following options for the line style are available.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Input Example(s)
Modifying
This leads automatically to a recalculation of the partial roof concerned which also means that the manual changes of the roof areas are undone.
Input options for the Members in Roof, Ceiling and Wall module
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
79
Input options for the Members in Roof, Ceiling and Wall module
This command is ONLY available for components, not for lines or surface areas.
End Type To allocate e.g. a rafter profile at the eaves point of several components.
End Type To allocate e.g. a tenon as connection between string and post.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Grid Check To check all roof edges and other marked edges that do not fit the roof grid. With the Position command these edges can be manually shifted to fit the roof grid. Or, alternatively, the automatic grid features can be used.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
81
. Macro To insert e.g. an octagonal roof macro. To intersect the macro with the roof, use the Cut command Partial Roof with Abut valley.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Input Example(s)
.. Macro To insert e.g. a 180 spiralled stair with Input Option 1 (fixed size).
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
83
DXF Export
Command and Brief Summary Input Mask
The export menu The program automatically assigns a file name which can later be changed. With the Save button, DXF export is started.
Via the Save as menu you can determine under which path you want to save the DXF file.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
DXF Import
Command and Brief Summary Input Mask
File selection After you have selected the file you want to import, click the Open button this dialog box is closed and a second one opened:
The import menu Here you can see the DXF file in the preview window. If the file consists of several layers, they are listed in the layer window and can be activated or deactivated. All active layers ( ) are imported into the active building project once you start the import process (click the Import button).
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.
85
Exercises
Creating an offer/quotation for a partial-hip roof Command and Brief Summary Input Mask
EXERCISES
Dimensions
To create the profiles Task To create the roof design To put together an offer with the summary calculation
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +498304939-0 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2007 by SEMA GmbH.
Copy the eaves purlin into the roof extension. Shorten the copied purlin with the Cut command.
Create a construction plane that is parallel to the rafter. Then draw a house wall of 4m height under the eaves purlin with CAD.
EXERCISES
3D image after copying the complete construction plane to the other side of the roof extension.
SEMA GmbH Dorfmhlstrae 7-11 87499 Wildpoldsried Phone +49 83049390 Fax +498304939-240 Internet: http://www.sema-soft.com E-Mail: sema@sema-soft.com 2006 by SEMA GmbH.