Você está na página 1de 60

Heavy Duty Fixings

For Concrete and Masonry


C-SL-2009E

European Technical Approval

We are pleased to present you with the 2009 Liebig product catalogue. Since its pioneering work in fastening technology began in 1946, Liebig has specialised in the development of high quality, innovative structural anchors. At the beginning of 2008 Liebig was purchased by Simpson Strong-Tie, an organisation that also has a long history of structural connector and anchor expertise. Together our two companies will provide you with the high quality products and enhanced customer support that you deserve. Heres what you can expect. Testing Innovation and Performance
For many years Liebig has been a leader in the research and development of heavy-duty undercutting anchor technology. This history will continue with Simpson Strong-Tie and its global focus on R&D and testing. Simpsons work has led to the creation of many anchor products that significantly improve the safety of homes, buildings, and other structures. Our state-of-the-art laboratory facilities are constantly testing new and existing products to provide you with the best connecting and anchoring solutions and with the information you need in order to design with and properly install our products.

Technical approvals
Knowing that our products are extensively tested provides you with the reassurance that they will perform in the toughest conditions. Many of the products contained in this catalogue have been used in the most demanding safetyoriented applications such as nuclear power plants. Most Liebig anchors are compliant with the highest European European Technical Approval Technical Approvals for cracked and non cracked concrete.

Customer Support
The quality and variety of our product line provides engineers and builders with design flexibility while offering reliable and proven performance. In addition, customers can count on our engineering technical support, experienced field representatives and training programs. To learn more about the Liebig product line, please visit our website or call us. We look forward to working with you. www.simpson-liebig.com

Why Simpson Strong-Tie/Liebig?


> Pioneer in Code-Compliant anchors > History of Research and State-of-the-Art Testing > Innovative Product Design > Technical Support > High Load Capacities > Reliable, Consistent Performance
This catalogue is owned by Simpson Strong-Tie. A complete or partial copy is not allowed without written authorisation.

Simpson Strong-Tie was founded in the United States and has been manufacturing wood-to-wood and wood-to-concrete connectors since 1956. Since then, Simpson Strong-Tie has grown to be the worlds largest manufacturer of construction connectors and has expanded into anchoring and fastening solutions for concrete, masonry and steel. In 1995, Simpson Strong-Tie established an Anchor Systems division and expanded its product offering to include mechanical anchors, chemical anchors, restoration adhesives, powder-actuated tools/fasteners and carbide drill bits. With anchor manufacturing and adhesive formulating facilities in North America, Asia and Europe, the company continues to develop new products that offer higher performance, easier installation and a lower installed cost.

CONTENTS

Page Anchor Selection Guide 4-5

Undercut Anchor Systems


ULTRAPLUS UP SUPERPLUS BLS, ILS SUPERPLUS STEP IRON ANCHOR SA SUPERPLUS LIGHTNING PROTECTION ANCHOR BA 6-11 12-17 18 19

Expansion Anchor Systems

SAFETY BOLT B, S, SK

20-27

LIEBIG ANCHOR AB, AS THROUGHBOLT BOA-X AND BOAX-II WECO-BRASS ANCHOR

28-33 34-39 56

Adhesive Anchor Systems


VESF INJECTION 2000 LSK AND LVK
C-SL-2009E 2009 SIMPSON STRONG-TIE

40-43 44-47 48-51 52-55

CHEMICAL ANCHOR PLUS KLS, KLP

Accessories
Ring bolts, Stud Connectors, Specials, Quick Set Drive, Applicator guns 57-58

Service
FAX ENQUIRY FORM
Simpson Strong-Tie Ireland Ltd. reserves the right to change specications, designs, and models without notice or liability for such changes.

59

ANCHOR SELECTION GUIDE

Non-Cracked Concrete

Anchoring Principle

Cracked Concrete

Type ULTRAPLUS SUPERPLUS SAFETY BOLT LIEBIG ANCHOR BOA-X AND BOAX-II VESF INJECTION 2000 LSK AND LVK CHEMICAL ANCHOR PLUS WECO-BRASS ANCHOR
6 12 20 28 34 40 44 48 52 56

Undercut Anchor Systems


This type of anchor transfers load into the base material through mechanical interlock with an undercut that is formed in the base material. The undercut can be formed before or during setting of the anchor. These systems have very high reliability and performance.

Expansion Anchor Systems


This type of anchor transfers load into the base material through friction grip that is established between the anchors expansion sleeve and the sidewalls of the drilled hole. This occurs when the anchor is set and the cone is drawn into the expansion sleeve. Expansion anchors provide a reliable and economical xing system.

Adhesive Anchor Systems


This type of anchor consists of a chemical mortar and a threaded metal stud. After installation a chemical reaction takes place that secures the stud in place and the chemical bonds to the sidewalls of the drilled hole. This system does not produce expansion forces, and therefore allows for smaller edge distances and spacings.

Hollow Masonry

Page

Tension Zone Anchor This anchor is suitable and approved for use in cracked (tension zone) and non-cracked (compression zone) concrete.

Compression Zone Anchor This anchor is suitable and approved for use in non-cracked (compression zone) concrete.

Hollow Masonry This anchor is suitable and approved for use in solid masonry meeting DIN 1053.

Solid Masonry This anchor is suitable and approved for use in solid masonry meeting DIN 1053.

European Technical Approval This anchor has been approved for construction applications in accordance with European Technical Approval Guidelines (ETAG).

European Conformity Mark This product meets the requirements of the European Technical Approval and can be used without restriction in the European Union.

German National Approval This product has been approved for construction applications by the Deutsches Institut fr Bautechnik.

Fire Resistance Suitable for use in fire protection applications.

C-SL-2009D 2009 SIMPSON STRONG-TIE

ANCHOR SELECTION GUIDE

A4 Stainless Steel

DIBt Approval

Extraordinary Loads

ETA-Approval

Civil Defense

Load Range

European Technical Approval

Option 1 Option 1 Option 1 Option 1 Option 1 (carbon steel) Option 4 (A4) Option 7 (carbon steel) (A4-pending)

19320.2 kN 4.356.1 kN 2.448.9 kN 2.437.2 kN 1.821.4 kN 5.346.9 kN 4.927.4 kN 0.31.7 kN 4.060 kN 0.52.5 kN

Corrosion Resistance
Corrosion is the destruction of metal through chemical or electrochemical attack by the environment. In most indoor conditions carbon steel anchors with zinc plating provide sufcient corrosion resistance. Stainless steel (A4) anchors are usually suitable for outdoor or damp indoor conditions. Stainless steel anchors with special corrosion resistant properties are necessary for aggressive conditions such as roadway tunnels or chloride atmospheres.

Approved Anchors
To ensure that an anchor is capable of resisting the intended external loads, the anchor must be suitable for the intended application and installed in accordance with the manufacturers recommended installation instructions. Anchors with independent technical approvals (such as DIBt or ETA) have demonstrated suitable behavior and performance for use in construction applications.

This anchor meets the requirements of VdS CEA 4001.

C-SL-2009D 2009 SIMPSON STRONG-TIE

Suitable for use in civil defense structures according to the Guidelines of the German Federal Agency for the Protection of Population and Catastrophe Assistance.

Suitable for use in resisting special and extraordinary loads such as shocks and earthquakes.

Available in carbon steel, zinc plated and blue passivated.

Available in A4 stainless steel.

Permissible tension load.

Calculation software.

Calculation Software

5

Steel, Zinc Plated

Fire Resistance

Sprinklers

Solid Masonry

ULTRAPLUS M12 M36


The undercut anchor for exceptionally high loads in cracked and non-cracked concrete also for shock and earthquake loads.

Function: When the anchor is installed the expansion segments are driven down to the undercut in the drilled hole. The spring pressure automatically expands the segments into the undercut with an audible click. This results in a mechanical undercut connection without any expansion pressure. The positive undercut allows perfect bearing of the segments and ensures reliable transmission of the load into the concrete. Benefits: Dependable fixing for high loads in cracked and non-cracked concrete High safety margins due to positive undercutting High strength threaded rod Grade 10.9 The spring automatically compensates for tolerances in the fixture thickness Reduced edge distances and spacings Custom lengths available Proven performance history in resisting dynamic loads, shock loads, and earthquakes. Expert reports available for these and other applications.

C-SL-2009E 2009 SIMPSON STRONG-TIE

Undercut Anchor Systems

ULTRAPLUS
CONSTRUCTION: UP with hex nut, washer, threaded stud and plastic retaining ring

MATERIAL: Grade 10.9 carbon steel, zinc plated and blue passivated BASE MATERIAL: Cracked and non-cracked concrete: C20/25 to C50/60 APPROVAL: ETA-04/0099 Option 1 Carbon steel, zinc plated LOAD RANGE: Tension: Shear: Nperm = 19.0 - 320.2 [kN] Vperm = 45.2 - 371.4 [kN]

R 120

PRODUCT RANGE: UP: M12 M36, carbon steel, zinc plated and blue passivated CHARACTERISTICS: Positive undercut anchor with strong mechanical interlock Immediately loadable Through-fix installation APPLICATIONS: Steel construction Industrial plants Nuclear power plants BENEFITS: High tension and shear capacities Custom lengths available Positive undercutting (comparable performance to a cast-in headed stud) PRODUCT DESCRIPTION: The ULTRAPLUS undercut anchor is designed for use in applications where reliability and safety are essential, e.g. for anchoring safety relevant components in nuclear power plants, for industrial plants, conveyor systems, cranes, and also for special civil engineering solutions. The LIEBIG ULTRAPLUS was developed to resist very high loads with its unique undercutting technology. After the hole is drilled, a separate undercut is drilled using a special LIEBIG undercutting tool. When the anchor is inserted through the fixture, spring pressure opens the expanding segments. They lock into the undercut with a clearly audible click. The result is a mechanical interlock without expansion stresses. By applying the specified torque, the fixture is fastened in position. The positive undercut allows perfect bearing of the segments and ensures reliable transmission of the load into the concrete. Conveyor systems Cranes Expansion pressure free Small edge distances and spacings Completely removable

C-SL-2009E 2009 SIMPSON STRONG-TIE

Undercut Anchor Systems

ULTRAPLUS
Carbon steel, zinc plated
ULTRAPLUS UP
Threaded stud with hex nut and washer Material: Grade 10.9 carbon steel, zinc plated and blue passivated Approval: ETA-04/0099 Option 1 Thread Size x Depth of Drilled Hole d o x h1 [mm] UP M12-23/140/20 UP M16-30/220/30 UP M20-36/250/50 UP M24-45/280/60* UP M36-67/420/100* UP1223140020 UP1630220030 UP2036250050 UP2445280060 UP3667420100 M12 M16 M20 M24 M36 [mm] 23 x 190 30 x 300 36 x 330 45 x 410 67 x 570 Max. Fixture Thickness tx [mm] 20 30 50 60 100 Fixture Hole df [mm] 24 32 38 46 68 Eff. Embedment Depth hef [mm] 140 220 250 280 420 Total Length L [mm] 220 325 380 460 700 [kg/100 pcs] 48.0 123.0 173.0 408.0 1305.0 [pcs] 10 5 5 2 1 Box Quantity

Type

Order Code

Weight

*Not included in approval. Available as special order. Custom lengths available on request.

Installation Accessories
Hand undercutting tool with lever Undercutting tool for core drilling rigs with 1/2" drive Diamond cutting blade

Compatible ULTRAPLUS M12 M16 M20 M24 M36

Order Code DH23 DH30 DH36 DH45 DH67

kg/pc 3.5 4.0 5.0 6.0 9.0

Compatible ULTRAPLUS M12 M16 M20 M24 M36

Order Code D23 D30 D36 D45 D67

kg/pc 2.6 3.1 4.1 5.1 8.1

Compatible ULTRAPLUS M12 M16 M20 M24 M36

Order Code DE23 DE30 DE36 DE45 DE67

kg/10 pcs 0.5 1.0 1.2 2.1 3.3

Special lengths upon request. Both types of undercutting tools are available for either purchase or hire.

C-SL-2009E 2009 SIMPSON STRONG-TIE

Undercut Anchor Systems

ULTRAPLUS TECHNICAL DATA


Carbon steel, zinc plated
Permissible loads for single anchors with no inuencing edge distances or spacings. Loads are calculated using partial safety factors from ETAG 001 and the characteristic anchor and installation data from this catalogue. Design calculations shall follow the requirements of ETA-04/0099. Material: Carbon steel, Grade 10.9, zinc plated and blue passivated
Thread size Effective embedment depth (hef) Type UP... Permissible tension loads1) Cracked concrete C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60 M12 140 M12-23/140/ 19.0 23.2 26.9 29.5 28.6 34.9 40.3 43.4 45.2 45.2 45.2 45.2 45.2 45.2 45.2 45.2 62.4 140 420 140 210 140 240 23 190 35 6 24 14 24 120 M16 220 M16-30/220/ 35.7 43.6 50.4 55.4 45.2 55.2 63.8 70.1 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 158.1 220 660 220 330 220 360 3306) 30 300 47 8.5 32 18 36 250 M20 250 M20-36/250/ 45.2 55.2 63.8 70.1 66.7 81.3 94.0 103.3 109.5 109.5 109.5 109.5 109.5 109.5 109.5 109.5 309.0 250 750 250 375 250 400 3606) 36 330 53.5 8.75 38 22 41 300 M24 280 M24-45/280/ 80.3 98.0 113.3 124.5 111.9 136.5 157.8 173.5 160.6 161.9 161.9 161.9 161.9 161.9 161.9 161.9 534.5 280 840 280 420 280 500 45 410 74 14.5 46 26 50 790 M36 420 M36-67/420/ 147.6 180.0 208.1 228.7 206.6 252.0 291.3 320.2 295.1 360.0 371.4 371.4 371.4 371.4 371.4 371.4 1881.7 420 1260 420 630 420 700 67 570 105 19 68 39 75 2000

[mm]

Nperm

Non-cracked concrete3)

[kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN] [Nm]

Permissible shear loads1) 2) Cracked concrete

Vperm

Non-cracked concrete3)

Permissible bending moments1) 5) Mperm

Spacings, edge distances and member thicknesses [mm] Effective embedment depth hef scr, N [mm] Characteristic spacing4) [mm] Minimum spacing smin ccr, N [mm] Characteristic edge distance4) [mm] Minimum edge distance cmin hmin [mm] Minimum member thickness Installation data Drill hole diameter Drill hole depth Diameter of undercutting Undercutting Clearance Through-x hole in the anchorage xture Installation on threaded stud Width across ats Installation torque Installed anchor
C-SL-2009E 2009 SIMPSON STRONG-TIE

d0 h1 d1 dcut df df sw Tinst

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [Nm]

1) The permissible loads have been calculated using the partial safety factors for resistances stated in the ETA-approval and a partial safety factor for actions of F = 1.4. The permissible loads are valid for unreinforced concrete and reinforced concrete with a rebar spacing s 15 cm and reinforced concrete with a rebar spacing s 10 cm if the rebar is 10 mm or smaller. 2) The permissible shear loads are based on a single anchor without inuencing concrete edges. For shear loads applied close to an edge (c 10 hef or 60 d) concrete edge failure must be checked per ETAG 001, Annex C, design method A. 3) Concrete is considered non-cracked when the tensile stress within the concrete is L + R 0. In the absence of detailed verication R = 3 N/mm can be assumed (L equals the tensile stress within the concrete as a result of external loads, forces on anchors included). 4) If spacings or edge distances become smaller than the characteristic values (i.e. s scr,N and/or c ccr,N) a calculation per ETAG 001, Annex C, design method A must be performed. For details, see ETA-04/0099. 5) The permissible bending moments are only valid for the threaded stud (e.g. in case of a distance mounting). 6) This hmin only applies when the remote face of the concrete is inspected to ensure there has been no break-through as a result of drilling. Otherwise hmin = 360 mm (M16) and hmin = 400 mm (M20). Complete your designs more easily by downloading our LIEBIG anchor software from our home-page: www.simpson-liebig.com

Undercut Anchor Systems

ULTRAPLUS
Installation

Drill hole.

Clean hole with a blow pump.

Create the undercut using LIEBIG undercutting tool (approximately 15 to 70 seconds depending on the anchor size). Irrigate with water while undercutting.

Install the LIEBIG ULTRAPLUS undercut anchor. The plastic ring holding the undercutting segments together will remain at the xture.

Apply the specied installation torque using a calibrated torque wrench the ULTRAPLUS undercut anchor is now installed and can resist loads immediately!
The ULTRAPLUS undercutting segments open with an audible CLICK as soon as they reach the undercut.

90

* The LIEBIG undercutting tool is available in models for use in core drilling rigs or as a hand undercutting tool with lever. Both models are available for hire or purchase.

The highstrength bolt provides a high safety margin

The knurls indicate the cate required embedment depth dment The pretensioned spring provides constant pressure and expands the undercut segments during installation

10

C-SL-2009E 2009 SIMPSON STRONG-TIE

Fixture

The plastic ring holding the segments together remains as the xture t th i th t

The segments expand as so soon as they reach the under undercut r

Undercut Anchor Systems

ULTRAPLUS
FIXING IN POWER PLANTS

LIEBIG ULTRAPLUS undercut anchors offer high safety, especially where extraordinary loads are present. With its unique undercutting technology, the ULTRAPLUS is the best solution.

INDUSTRIAL PLANTS/RETROFITS

The LIEBIG ULTRAPLUS undercut anchor can resist high loads problem-free, even at close anchor spacings. The application shown required a load capacity of 294 kN per anchor. Solution: LIEBIG ULTRAPLUS M36 with 630 mm embedment depth in C50/60 concrete.

C-SL-2009E 2009 SIMPSON STRONG-TIE

CHALLENGING APPLICATIONS

The LIEBIG ULTRAPLUS is the rst choice for unique applications with high loads.

11

SUPERPLUS
Self-undercutting anchor The undercut xing system that does not require a special setting tool.

Type BLS

Type ILS

Function: Automatically self-undercutting. The unique design of the SUPERPLUS causes an undercut to be created when the installation torque is applied. As torque is applied to the anchor the cone is drawn into the anchor sleeve and the sleeves outer cutting teeth expand and undercut into the base material. This results in a durable mechanical interlock with base material that functions in both cracked and non-cracked concrete. Benefits: High capacity in cracked and non-cracked concrete High reliability due to undercut technology Simple installation, no special drill bit or setting tool required Applying torque creates undercut Two approved embedment depths per diameter Lower installed cost than traditional undercut anchors Reduced edge distances and spacings

12

C SL 2009E C-SL-2009E 2009 SIMPSON STRONG-TIE STRONG TIE

Undercut Anchor Systems

SUPERPLUS
CONSTRUCTION: BLS ILS with hex nut, washer and threaded stud with internally threaded sleeve

MATERIAL: A4-80 stainless steel BASE MATERIAL: Cracked and non-cracked concrete: C20/25 to C50/60 APPROVALS: ETA-01/0011 Option 1 Carbon steel, zinc plated ETA-05/0013 Option 1 A4 stainless steel LOAD RANGE: Tension: Shear: Nperm = 4.3 - 56.1 [kN] Vperm = 4.3 - 90.7 [kN]

R 120

Grade 8.8 carbon steel, zinc plated and blue passivated

PRODUCT RANGE: BLS: M8, M12 and M16, carbon steel, zinc plated and blue passivated / A4 stainless steel ILS: M8, carbon steel, zinc plated and blue passivated APPLICATIONS: Power plants Steel and industrial plants Cable trays BENEFITS: High tension and shear capacity Simple self-undercutting installation No special drill bit or setting tool required PRODUCT DESCRIPTION: The LIEBIG SUPERPLUS is available in zinc plated carbon steel and A4 stainless steel. Its design offers the high load capacity and reliability of an undercut anchor, but with the ease of installation of an expansion anchor. In contrast to competing undercut anchor systems, the SUPERPLUS does not require special drill bits or setting tools. You need only apply the torque to create the self-undercut. INSTALLATION:
C-SL-2009E 2009 SIMPSON STRONG-TIE

Machines Facades Base plates

Reduced edge distances and spacings Two embedment depths per diameter Shallow embedment depths

Through-fix installation shown

90

Drill hole

Clean hole (blowing)

Insert anchor through fixture

Apply recommended fastening torque with a calibrated torque-wrench

Foto: Liebherr

13

Undercut Anchor Systems

SUPERPLUS
Carbon steel, zinc plated
SUPERPLUS BLS
Threaded stud with hex nut and washer Material: Grade 8.8 carbon steel, zinc plated and blue passivated Approvals: ETA-01/0011 Option 1 Thread Size x Depth of Drilled Hole d o x h1 [mm] BLS M8-14/40/15 BLS M8-14/80/25 BLS M12-20/80/15 BLS M12-20/80/30 BLS M12-20/150/30 BLS M12-20/150/50 BLS M16-25/150/30 BLS M16-25/150/40 BLS M16-25/150/60 BLS M16-25/200/40 BLS M16-25/200/60
See page 15 for technical data.

Type

Order Code

Max. Fixture Thickness tx [mm] 15 25 15 30 30 50 30 40 60 40 60

Fixture Hole df [mm] 16 16 21 21 21 21 26 26 26 26 26

Eff. Embedment Depth hef [mm] 40 80 80 80 150 150 150 150 150 200 200

Total Length L [mm] 80 130 130 145 215 235 220 230 250 280 300

Weight

Box Quantity

[mm] 14 x 60 14 x 100 20 x 105 20 x 105 20 x 175 20 x 175 25 x 185 25 x 185 25 x 185 25 x 235 25 x 235

[kg/100 pcs] 8.0 13.4 26.5 29.5 43.5 46.0 70.0 72.0 76.0 89.0 95.0

[pcs] 25 25 10 10 10 10 10 10 10 10 10

BLS0814040015 BLS0814080025 BLS1220080015 BLS1220080030 BLS1220150030 BLS1220150050 BLS1625150030 BLS1625150040 BLS1625150060 BLS1625200040 BLS1625200060

M8 M8 M12 M12 M12 M12 M16 M16 M16 M16 M16

Custom lengths available on request.

A4 stainless steel
SUPERPLUS BLS
Threaded stud with hex nut and washer Material: A4-80 stainless steel Approvals: ETA-05/0013 Option 1 x Depth of Drilled Hole d o x h1 [mm] BLS M8-14/80/25A4 BLS M12-20/80/15A4 BLS M12-20/80/30A4 BLS M16-25/150/30A4 BLS M16-25/150/40A4
See page 16 for technical data.
C-SL-2009E 2009 SIMPSON STRONG-TIE

Type

Order Code

Thread Size

Max. Fixture Thickness tx [mm] 25 15 30 30 40

Fixture Hole df [mm] 16 21 21 26 26

Eff. Embedment Depth hef [mm] 80 80 80 150 150

Total Length L [mm] 130 130 145 220 230

Weight

Box Quantity

[mm] 14 x 100 20 x 105 20 x 105 25 x 185 25 x 185

[kg/100 pcs] 13.4 26.5 29.5 70.0 72.0

[pcs] 25 10 10 10 10

BLS0814080025A4 BLS1220080015A4 BLS1220080030A4 BLS1625150030A4 BLS1625150040A4

M8 M12 M12 M16 M16

Custom lengths available on request.

Internally threaded, Carbon steel, zinc plated


SUPERPLUS ILS
Internally threaded sleeve Material: Grade 8.8 carbon steel, zinc plated and blue passivated x Depth of Drilled Hole d o x h1 [mm] ILS M8-14/80
Custom lengths available on request. See page 17 for technical data.

Type

Order Code

Thread Size

Max. Fixture Thickness tx [mm] -

Fixture Hole df [mm] 10

Eff. Embedment Depth hef [mm] 80

Total Length L [mm] 93

Weight

Box Quantity

[mm] 14 x 100

[kg/100 pcs] 8.7

[pcs] 25

ILS0814080

M8

14

Undercut Anchor Systems

SUPERPLUS TECHNICAL DATA Carbon steel, zinc plated


Permissible loads for single anchors with no inuencing edge distances or spacings. Loads are calculated using partial safety factors from ETAG 001 and the characteristic anchor and installation data from this catalogue. Design calculations shall follow the requirements of ETA-01/0011. Material: Carbon steel, Grade 8.8, zinc plated and blue passivated
Thread size Effective embedment depth (hef) Type BLS... Permissible tension loads1) Cracked concrete M8 40 M8-14/40/ M8 80 M8-14/80/ M12 80 M12-20/80/ M12 150 M12-20/150/ M16 150 M16-25/150/ M16 200 M16-25/200/

[mm]

Nperm

Non-cracked concrete3)

C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60

[kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN]

4.3 5.2 6.0 6.6 6.1 7.4 8.6 9.4

7.6 9.3 10.7 10.8 10.8 10.8 10.8 10.8

11.9 14.5 16.8 18.5 17.2 21.0 24.3 26.7

19.0 23.2 26.9 28.4 28.4 28.4 28.4 28.4

23.8 29.0 33.6 36.9 44.1 53.0 53.0 53.0

35.7 43.6 50.4 53.0 53.0 53.0 53.0 53.0

Permissible shear loads1) 2) Cracked concrete

Vperm

Non-cracked concrete3)

C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60

[kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN]

4.3 5.3 6.1 6.7 6.1 7.4 8.6 9.4

23.7 23.7 23.7 23.7 23.7 23.7 23.7 23.7

24.6 30.0 34.6 38.1 34.4 40.0 40.0 40.0

40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0

63.0 67.4 67.4 67.4 67.4 67.4 67.4 67.4

67.4 67.4 67.4 67.4 67.4 67.4 67.4 67.4

Permissible bending moments1) 4) Mperm

[Nm]

17.1

17.1

60.0

60.0

152.0

152.0

Spacings, edge distances and member thicknesses Effective embedment depth hef [mm] scr,N [mm] Characteristic spacing5) [mm] Minimum spacing smin [mm] Characteristic edge distance5) ccr,N [mm] Minimum edge distance cmin [mm] Minimum member thickness hmin Installation data Drill hole diameter Drill hole depth Through-x Clearance anchorage hole in the Installation on xture threaded stud Width across ats Installation torque Installed anchor

40 120 100 60 80 100

80 240 80 120 50 160

80 240 120 120 100 160

150 450 150 225 80 300

150 450 200 225 150 300

200 600 150 300 100 400

d0 h1 df df sw Tinst

[mm] [mm] [mm] [mm] [mm] [Nm]

14 60 16 10 17 25

14 100 16 10 17 25

20 105 21 14 22 80

20 175 21 14 22 80

25 185 26 18 27 180

25 235 26 18 27 180

C-SL-2009E 2009 SIMPSON STRONG-TIE

1) The permissible loads have been calculated using the partial safety factors for resistances stated in the ETA-approval and a partial safety factor for actions of F = 1.4. The permissible loads are valid for unreinforced concrete and reinforced concrete with a rebar spacing s 15 cm and reinforced concrete with a rebar spacing s 10 cm if the rebar is 10 mm or smaller. 2) The permissible shear loads are based on a single anchor without inuencing concrete edges. For shear loads applied close to an edge (c 10 hef or 60 d) concrete edge failure must be checked per ETAG 001, Annex C, design method A. 3) Concrete is considered non-cracked when the tensile stress within the concrete is L + R 0. In the absence of detailed verication R = 3 N/mm can be assumed (L equals the tensile stress within the concrete as a result of external loads, forces on anchors included). 4) The permissible bending moments are only valid for the threaded stud (e.g. in case of a distance mounting). 5) If spacings or edge distances become smaller than the characteristic values (i.e. s scr,N and/or c ccr,N) a calculation per ETAG 001, Annex C, design method A must be performed. For details, see ETA-01/0011. Complete your designs more easily by downloading our LIEBIG anchor software from our home-page: www.simpson-liebig.com

15

Undercut Anchor Systems

SUPERPLUS TECHNICAL DATA


A4 stainless steel
Permissible loads for single anchors with no inuencing edge distances or spacings. Loads are calculated using partial safety factors from ETAG 001 and the characteristic anchor and installation data from this catalogue. Design calculations shall follow the requirements of ETA-05/0013. Material: A4-80 stainless steel
Thread size Effective embedment depth (hef) Type BLS... Permissible tension loads1) Cracked concrete M8 40 M8-14/40/ M8 80 M8-14/80/ M12 80 M12-20/80/ M12 150 M12-20/150/ M16 150 M16-25/150/ M16 200 M16-25/200/

[mm]

Nperm

Non-cracked concrete3)

C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60

[kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN]

4.3 5.2 6.0 6.6 6.1 7.4 8.6 9.4

5.7 7.0 8.1 8.9 13.1 13.1 13.1 13.1

11.9 14.5 16.8 18.5 17.2 21.0 24.3 26.7

19.0 23.2 26.9 29.5 30.1 30.1 30.1 30.1

28.6 34.9 40.3 44.3 44.1 53.8 56.1 56.1

28.6 34.9 40.3 44.3 56.1 56.1 56.1 56.1

Permissible shear loads1) 2) Cracked concrete

Vperm

Non-cracked concrete3)

C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60

[kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN]

4.3 5.3 6.1 6.7 6.1 7.4 8.6 9.4

24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0

24.6 30.0 34.6 38.1 34.4 42.0 48.5 48.5

48.5 48.5 48.5 48.5 48.5 48.5 48.5 48.5

63.0 76.8 88.8 90.7 88.2 90.7 90.7 90.7

90.7 90.7 90.7 90.7 90.7 90.7 90.7 90.7

Permissible bending moment1) 4) Mperm

[Nm]

16.1

16.1

56.4

56.4

142.9

142.9

Spacings, edge distances and member thicknesses Effective embedment depth [mm] hef [mm] Characteristic spacing5) scr,N [mm] Minimum spacing smin [mm] Characteristic edge distance5) ccr,N [mm] Minimum edge distance cmin [mm] Minimum member thickness hmin Installation data Drill hole diameter Drill hole depth Through-x Clearance anchorage hole in the Installation on xture threaded stud Width across ats Installation torque Installed anchor

40 120 80 60 60 100

80 240 80 120 50 160

80 240 150 120 100 160

150 450 150 225 80 300

150 450 150 225 100 300

200 600 180 300 100 400

d0 h1 df df sw Tinst

[mm] [mm] [mm] [mm] [mm] [Nm]

14 60 16 10 17 25

14 100 16 10 17 25

20 105 21 14 22 80

20 175 21 14 22 80

25 185 26 18 27 180

25 235 26 18 27 180

1) The permissible loads have been calculated using the partial safety factors for resistances stated in the ETA-approval and a partial safety factor for actions of F = 1.4. The permissible loads are valid for unreinforced concrete and reinforced concrete with a rebar spacing s 15 cm and reinforced concrete with a rebar spacing s 10 cm if the rebar is 10 mm or smaller. 2) The permissible shear loads are based on a single anchor without inuencing concrete edges. For shear loads applied close to an edge (c 10 hef or 60 d) concrete edge failure must be checked per ETAG 001, Annex C, design method A. 3) Concrete is considered non-cracked when the tensile stress within the concrete is L + R 0. In the absence of detailed verication R = 3 N/mm can be assumed (L equals the tensile stress within the concrete as a result of external loads, forces on anchors included). 4) The permissible bending moments are only valid for the threaded stud (e.g. in case of a distance mounting). 5) If spacings or edge distances become smaller than the characteristic values (i.e. s scr,N and/or c ccr,N) a calculation per ETAG 001, Annex C, design method A must be performed. For details, see ETA-05/0013. Complete your designs more easily by downloading our LIEBIG anchor software from our home-page: www.simpson-liebig.com

16

C-SL-2009E 2009 SIMPSON STRONG-TIE

Undercut Anchor Systems

SUPERPLUS TECHNICAL DATA


Internally threaded anchor, Carbon steel, zinc plated
Permissible loads for single anchors with no inuencing edge distances or spacings. Loads are calculated using partial safety factors from ETAG 001 and the characteristic anchor and installation data from this catalogue. Material: Carbon steel, zinc plated and blue passivated
Thread size Effective embedment depth (hef) Type ILS... Permissible tension loads1) Cracked concrete M8 80 M8-14/80 Installed anchor

Grade 8.8

[mm]

Nperm

Non-cracked concrete3)

C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60

[kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN]

7.6 9.3 10.7 10.8 10.8 10.8 10.8 10.8

Permissible shear loads1)2) Cracked concrete

Vperm

Non-cracked concrete3)

C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60

[kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN]

8.4 8.4 8.4 8.4 8.4 8.4 8.4 8.4

Spacings, edge distances and member thicknesses hef Effective embedment depth scr, N Characteristic spacing4) Minimum spacing Characteristic edge distance Minimum edge distance Minimum member thickness Installation data Drill hole diameter Drill hole depth Clearance hole in the xture Threaded depth Hexagon socket depth Width across ats Installation torque
4)

[mm] [mm] [mm] [mm] [mm] [mm]

80 240 80 120 50 160

smin ccr, N cmin hmin

d0 h1 df Le Ti sw Tinst

[mm] [mm] [mm] [mm] [mm] [mm] [Nm]

14 100 10 12 to 23 4 8 25

Section A - A

C-SL-2009E 2009 SIMPSON STRONG-TIE

1) The permissible loads have been calculated assuming that grade 8.8 fasteners are used and using the partial safety factors for resistances stated in ETA-01/0011 and a partial safety factor for actions of F = 1.4. The permissible loads are valid for unreinforced concrete and reinforced concrete with a rebar spacing s 15 cm and reinforced concrete with a rebar spacing s 10 cm if the rebar is 10 mm or smaller. 2) The permissible shear loads are based on a single anchor without inuencing concrete edges. For shear loads applied close to an edge (c 10 hef or 60 d) concrete edge failure must be checked per ETAG 001, Annex C, design method A. 3) Concrete is considered non-cracked when the tensile stress within the concrete is L + R 0. In the absence of detailed verication R = 3 N/mm can be assumed (L equals the tensile stress within the concrete as a result of external loads, forces on anchors included). 4) If spacings or edge distances become smaller than the characteristic values (i.e. s scr,N and/or c ccr,N) a calculation per ETAG 001, Annex C, design method A must be performed. For details, see ETA-01/0011. Complete your designs more easily by downloading our LIEBIG anchor software from our home-page: www.simpson-liebig.com

17

Undercut Anchor Systems

SUPERPLUS
Step Iron Anchor, A4 stainless steel
BLS M8-14/40SA A4
Threaded stud with hex nut and special plastic sleeve Material: A4-80 stainless steel Approvals: ETA-05/0013 - Option 1, Expert Report AZ.: 05003 Thread Size [mm] BLS M8-14/40SA A4 BLS0814040SAA4 M8 x Depth of Drilled Hole [mm] 14 x 60 Max.Fixture Thickness [mm] 20 Fixture Hole [mm] 16 Eff. Embedment Depth [mm] 40 Total Length [mm] 85 Box Quantity [pcs] 25

Type

Order Code

Weight [kg/100 pcs] 9.0

Technical Data
Type Thread size Eff. embedment depth Min. edge distance Min. member thickness Installation data Drilled hole diameter Drilled hole depth Step iron thickness Step iron hole diameter Wrench size Installation torque d0 h1 tx df sw Tinst [mm] [mm] [mm] [mm] [mm] [Nm] 14 60 20 16 17 25 hef cmin hmin [mm] [mm] [mm] BLS M8-14/40SA A4 M8 40 60 100
Installed anchor

Benets:
High safety from mechanical interlock Self undercutting when torque is applied Special plastic sleeve prevents contact corrosion between the step iron and the anchor Saves cost due to quick installation No special tools or special drill bits required Easy to install, even in difficult to access areas
C-SL-2009E 2009 SIMPSON STRONG-TIE

18

Undercut Anchor Systems

SUPERPLUS
Lightning Protection Anchor, Carbon steel, zinc plated
BLS M8-14BS85
Threaded stud with hex nut and washer Material: Grade 8.8 Carbon steel, zinc plated and blue passivated Type Order code Thread Size [mm] BLS M8-14BS85 BLS0814BS085 M8
Custom lengths available on request.

x Depth of Drilled Hole [mm] 14 x 40 to 60

Total Length [mm] 85

Weight [kg/100 pcs] 7.2

Box Quantity [pcs] 25

Lightning Protection Anchor, A4 stainless steel


BLS M8-14BS85 A4
Threaded stud with hex nut and washer Material: A4 stainless steel Type Order code Thread Size [mm] BLS M8-14BS85 A4 BLS0814BS085A4 M8
Custom lengths available on request.

x Depth of Drilled Hole [mm] 14 x 40 to 60

Total Length [mm] 85

Weight [kg/100 pcs] 7.2

Box Quantity [pcs] 25

Installed anchor

BLS M8-14BS85

Retrofitted grounding systems connected to reinforcing bars with the LIEBIG LIGHTNING PROTECTION ANCHOR.

Reinforcing bar

Installation

TInst = 25 Nm
C-SL-2009E 2009 SIMPSON STRONG-TIE

Locate reinforcing bar.

Drill up to the reinforcing bar.

Clean hole.

Set anchor.

Apply recommended fastening torque with a calibrated torque wrench.

Detail "X"
TInst = 15 Nm

"X"
Remove the hex nut, washer and distance sleeve. Screw in the threaded stud until in contact with the reinforcing bar. Fill annular gap completely with injection mortar.
Attach grounding lug.

Contact area between reinforcing bar and Lightning Protection Anchor

19

SAFETY BOLT
Twin-cone heavy duty bolt with cylindrical expansion for increased anchoring security.

Type B

Type S

Type SK

Function: Application of the installation torque causes the anchors two opposing cones to be drawn into the expansion sleeve. This causes the sleeve to be pressed against the sidewalls of the hole over its entire length and results in optimum frictional resistance and high load capacity in cracked and non-cracked concrete. Benefits: High capacity in cracked and non-cracked concrete Cylindrical expansion of sleeve over entire length Solid all-steel construction Torque indication from domed washer

Uninstalled

Installed

20

C SL 2009E 2009 C-SL-2009E 2009 SIMPSON STRONG-TIE STRONG TIE

Expansion Anchor Systems

SAFETY BOLT
CONSTRUCTION: B S SK with hex nut, domed washer and threaded stud with hex head screw and domed washer with countersunk headed screw

MATERIAL:

R 120

Grade 8.8 carbon steel, zinc plated and blue passivated A4-80 stainless steel (Type B), A4-70 stainless steel (Type S, SK) BASE MATERIAL: Cracked and non-cracked concrete: C20/25 to C50/60 APPROVAL: ETA-06/0108 Option 1 Carbon steel, zinc plated LOAD RANGE: Tension: Shear: Nperm = 2.4 - 48.9 [kN] Vperm = 5.2 - 80.6 [kN]

PRODUCT RANGE: B: M6 M20, carbon steel, zinc plated and blue passivated / A4 stainless steel S: M6 M20, carbon steel, zinc plated and blue passivated / M6 M12, A4 stainless steel SK: M6 M16, carbon steel, zinc plated and blue passivated / M6 M12, A4 stainless steel APPLICATIONS: Steel construction Railing Gates Lifting systems BENEFITS: Cylindrical expansion with optimal friction resistance Higher anchoring intensity from twin-cone design Torque indication from domed washer PRODUCT DESCRIPTION: Twin-cone sleeve anchor for high loads Torque-controlled mechanical anchor Solid, all-steel construction INSTALLATION: Through-fix installation
C-SL-2009E 2009 SIMPSON STRONG-TIE

Cable trays Machines Facades Base plates

90

Drill hole

Clean hole (blowing)

Insert anchor through fixture

Apply recommended fastening torque with a calibrated torque-wrench

21

Expansion Anchor Systems

SAFETY BOLT
Carbon steel, zinc plated
SAFETY BOLT B
Threaded stud with hex nut and domed washer Material: Grade 8.8 carbon steel, zinc plated and blue passivated Approvals: ETA-06/0108 Option 1 New Type Old Type Order Code Thread Size x Max. Depth of Fixture Drilled Hole Thickness do x h1 [mm] B M6-10/45/5 B M6-10/45/15 B M6-10/45/40 B M8-12/55/5 B M8-12/55/15 B M8-12/55/40 B M8-12/55/65 B M8-12/55/100 B M10-15/70/5 B M10-15/70/15 B M10-15/70/40 B M10-15/70/65 B M10-15/70/100 B M12-20/80/5 B M12-20/80/15 B M12-20/80/40 B M12-20/80/65 B M12-20/80/100 B M16-25/100/5 B M16-25/100/15 B M16-25/100/40 B M16-25/100/65 B M16-25/100/100 B M20-30/125/15* B M20-30/125/40* B M20-30/125/65* B 10/20 B 10/35 B 10/60 B 12/25 B 12/40 B 12/65 B 12/90 B 12/125 B 15/30 B 15/45 B 15/70 B 15/95 B 15/120 B 20/35 B 20/50 B 20/75 B 20/100 B 20/135 B 25/40 B 25/55 B 25/80 B 25/105 B 25/130 B 30/65 B 30/90 B 30/115 LB0610045005 LB0610045015 LB0610045040 LB0812055005 LB0812055015 LB0812055040 LB0812055065 LB0812055100 LB1015070005 LB1015070015 LB1015070040 LB1015070065 LB1015070100 LB1220080005 LB1220080015 LB1220080040 LB1220080065 LB1220080100 LB1625100005 LB1625100015 LB1625100040 LB1625100065 LB1625100100 B2030125015 B2030125040 B2030125065 B2030125100 M6 M6 M6 M8 M8 M8 M8 M8 M10 M10 M10 M10 M10 M12 M12 M12 M12 M12 M16 M16 M16 M16 M16 M20 M20 M20 M20 [mm] 10 x 60 10 x 60 10 x 60 12 x 70 12 x 70 12 x 70 12 x 70 12 x 70 15 x 85 15 x 85 15 x 85 15 x 85 15 x 85 20 x 100 20 x 100 20 x 100 20 x 100 20 x 100 25 x 125 25 x 125 25 x 125 25 x 125 25 x 125 30 x 150 30 x 150 30 x 150 30 x 150 tx [mm] 5 15 40 5 15 40 65 100 5 15 40 65 100 5 15 40 65 100 5 15 40 65 100 15 40 65 100 Eff. Fixture Embedment Hole Depth df [mm] 12 12 12 14 14 14 14 14 17 17 17 17 17 21 21 21 21 21 26 26 26 26 26 32 32 32 32 hef [mm] 45 45 45 55 55 55 55 55 70 70 70 70 70 80 80 80 80 80 100 100 100 100 100 125 125 125 125 Total Length L [mm] 70 80 105 85 95 120 145 180 100 110 135 160 195 120 130 155 180 215 150 160 185 210 245 180 205 230 265 [kg/100 pcs] 2.7 3.4 4.6 5.8 7.0 9.0 10.6 12.7 11.0 12.8 16.0 18.5 22.0 20.8 24.8 29.0 33.5 39.8 43.4 48.4 56.7 63.6 75.0 85.9 96.7 107.6 122.0 [pcs] 50 50 50 25 25 25 25 25 25 25 10 10 10 10 10 10 10 20 5 5 5 10 10 5 5 5 5 Box Quantity

Weight

B M20-30/125/100* B 30/150
Custom lengths available on request. *Not included in approval.

22

C-SL-2009E 2009 SIMPSON STRONG-TIE

Expansion Anchor Systems

SAFETY BOLT TECHNICAL DATA


Carbon steel, zinc plated
Permissible loads for single anchors with no inuencing edge distances or spacings. Loads are calculated using partial safety factors from ETAG 001 and the characteristic anchor and installation data from this catalogue. Design calculations shall follow the requirements of ETA-06/0108. Material: Carbon steel, Grade 8.8, zinc plated and blue passivated
Thread size Effective embedment depth (hef) Type B... Permissible tension loads1) Cracked concrete M6 45 M6-10/45/ M8 55 M8-12/55/ M10 70 M10-15/70/ M12 80 M12-20/80/ M16 100 M16-25/100/ M207) 125 M20-30/125/

[mm]

Nperm

Non-cracked concrete3)

C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60

[kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN]

2.4 2.9 3.4 3.7 3.0 3.6 4.2 4.6

3.6 4.4 5.0 5.5 4.8 5.8 6.7 7.4

7.6 9.3 10.7 11.8 9.5 11.6 13.4 14.8

12.3 15.0 17.3 19.0 17.2 21.0 24.2 26.6

17.1 20.9 24.2 26.6 24.0 29.3 33.8 37.2

18.6 22.7 26.2 28.8 31.6 38.5 44.5 48.9

Permissible shear loads1) 2) Cracked concrete

Vperm

Non-cracked concrete3)

C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60

[kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN]

5.2 6.3 7.3 8.0 7.2 8.6 8.6 8.6

7.0 8.5 9.9 10.8 9.8 11.9 13.8 14.3

20.1 22.3 22.3 22.3 22.3 22.3 22.3 22.3

24.5 29.8 34.3 34.3 34.3 34.3 34.3 34.3

34.3 41.7 48.5 53.1 48.0 54.9 54.9 54.9

49.2 59.8 61.6 76.3 68.9 80.6 80.6 80.6

Permissible bending moments1) 4) Mperm

[Nm]

6.9

17.1

34.3

60.0

152.0

296.6

Spacings, edge distances and and member thicknesses [mm] Effective embedment depth hef scr,N [mm] Characteristic spacing5) [mm] Minimum spacing smin [mm] Characteristic edge distance ccr,N cmin [mm] Minimum edge distance6) [mm] Minimum member thickness hmin Installation data Drill hole diameter Drill hole depth Through-x Clearance anchorage hole in the Installation on xture threaded stud Width across ats Installation torque Installed anchor d0 h1 df df sw Tinst [mm] [mm] [mm] [mm] [mm] [Nm]
L

45 135 60 67.5 80 100

55 165 100 82.5 100 110

70 210 150 105 150 140

80 240 200 120 200 160

100 300 250 150 250 200

125 375 195 185 350 250

10 60 12 7 10 8

12 70 14 9 13 15

15 85 17 12 17 40

20 100 21 14 19 70

25 125 26 18 24 115

30 150 32 22 32 300

sw
C-SL-2009E 2009 SIMPSON STRONG-TIE

Tinst

d0

h ef h1 h min

tfix

df

Flattening of domed washer = visual installation check

Untorqued

Torqued

1) The permissible loads have been calculated using the partial safety factors for resistances stated in the ETA-approval and a partial safety factor for actions of F = 1.4. The permissible loads are valid for unreinforced concrete and reinforced concrete with a rebar spacing s 15 cm and reinforced concrete with a rebar spacing s 10 cm if the rebar is 10 mm or smaller. 2) The permissible shear loads are based on a single anchor without inuencing concrete edges. For shear loads applied close to an edge (c 10 hef or 60 d) concrete edge failure must be checked per ETAG 001, Annex C, design method A. 3) Concrete is considered non-cracked when the tensile stress within the concrete is L + R 0. In the absence of detailed verication R = 3 N/mm can be assumed (L equals the tensile stress within the concrete as a result of external loads, forces on anchors included). 4) The permissible bending moments are only valid for the threaded stud (e.g. in case of a distance mounting). 5) For spacings smaller than the characteristic values (i.e. s scr,N) a calculation per ETAG 001, Annex C, design method A shall be performed. For details, see ETA-06/0108. 6) The actual edge distance shall not be less than the value of cmin shown in the table. 7) Size M20 is not included in the approval.
Complete your designs more easily by downloading our LIEBIG anchor software from our home-page: www.simpson-liebig.com

23

Expansion Anchor Systems

SAFETY BOLT
Carbon steel, zinc plated
SAFETY BOLT S
Hex head screw and domed washer Ausfhrung: Grade 8.8 carbon steel, zinc plated and blue passivated Approvals: ETA-06/0108 Option 1 New Type Old Type Order Code Thread Size x Max. Depth of Fixture Drilled Hole Thickness do x h1 [mm] S M6-10/45/5 S M6-10/45/15 S M6-10/45/40 S M8-12/55/5 S M8-12/55/15 S M8-12/55/40 S M10-15/70/5 S M10-15/70/15 S M10-15/70/40 S M12-20/80/5 S M12-20/80/15 S M12-20/80/40 S M16-25/100/5 S M16-25/100/15 S M16-25/100/40 S M20-30/125/15* S M20-30/125/40*
*Not included in approval.

Fixture Hole df [mm] 12 12 12 14 14 14 17 17 17 21 21 21 26 26 26 32 32

Eff. Embedment Depth hef [mm] 45 45 45 55 55 55 70 70 70 80 80 80 100 100 100 125 125

Total Length L [mm] 70 80 105 80 90 115 95 105 130 113 123 148 145 155 180 180 205

Weight

Box Quantity

tx [mm] 5 15 40 5 15 40 5 15 40 5 15 40 5 15 40 15 40

[mm] 10 x 60 10 x 60 10 x 60 12 x 70 12 x 70 12 x 70 15 x 85 15 x 85 15 x 85 20 x 100 20 x 100 20 x 100 25 x 125 25 x 125 25 x 125 30 x 150 30 x 150

[kg/100 pcs] 2.7 3.4 4.6 5.8 7.0 9.0 11.0 12.8 16.0 20.8 24.8 29.0 43.4 48.4 56.7 85.9 96.7

[pcs] 50 50 50 25 25 25 25 25 10 10 10 10 5 5 5 5 5

S 10/20 S 10/35 S 10/60 S 12/25 S 12/40 S 12/65 S 15/30 S 15/45 S 15/70 S 20/35 S 20/50 S 20/75 S 25/40 S 25/55 S 25/80 S 30/65 S 30/90

LS0610045005 LS0610045015 LS0610045040 LS0812055005 LS0812055015 LS0812055040 LS1015070005 LS1015070015 LS1015070040 LS1220080005 LS1220080015 LS1220080040 LS1625100005 LS1625100015 LS1625100040 S2030125015 S2030125040

M6 M6 M6 M8 M8 M8 M10 M10 M10 M12 M12 M12 M16 M16 M16 M20 M20

Custom lengths available on request.

SAFETY BOLT SK
Countersunk head screw Grade 8.8 carbon steel, zinc plated and blue passivated Approvals: ETA-06/0108 Option 1 New Type Old Type Order Code Thread Size x Max. Depth of Fixture Drilled Hole Thickness do x h1 [mm] SK M6-10/45/6 SK M6-10/45/15 SK M6-10/45/40 SK M8-12/55/10 SK M8-12/55/15 SK M8-12/55/40 SK M10-15/70/10 SK M10-15/70/15 SK M10-15/70/40 SK M12-20/80/15 SK M12-20/80/40 SK M16-25/100/15 SK M16-25/100/40 SK 10/20 SK 10/35 SK 10/60 SK 12/25 SK 12/40 SK 12/65 SK 15/30 SK 15/45 SK 15/70 SK 20/50 SK 20/75 SK 25/55 SK 25/80 LSK0610045006 LSK0610045015 LSK0610045040 LSK0812055010 LSK0812055015 LSK0812055040 LSK1015070010 LSK1015070015 LSK1015070040 LSK1220080015 LSK1220080040 LSK1625100015 LSK1625100040 M6 M6 M6 M8 M8 M8 M10 M10 M10 M12 M12 M16 M16 [mm] 10 x 60 10 x 60 10 x 60 12 x 70 12 x 70 12 x 70 15 x 85 15 x 85 15 x 85 20 x 100 20 x 100 25 x 125 25 x 125 tx [mm] 6 15 40 10 15 40 10 15 40 15 40 15 40 Fixture Hole df [mm] 12 12 12 14 14 14 17 17 17 21 21 26 26 Eff. Embedment Depth hef [mm] 45 45 45 55 55 55 70 70 70 80 80 100 100 Total Length L [mm] 60 70 95 75 85 110 90 100 120 110 135 135 160 [kg/100 pcs] 2.7 3.4 4.6 5.8 7.0 9.0 11.0 12.8 16.0 24.8 29.0 48.4 56.7 [pcs] 50 50 25 25 25 25 25 25 10 10 5 5
C-SL-2009E 2009 SIMPSON STRONG-TIE

Weight

Box Quantity

50

Custom lengths available on request.

24

Expansion Anchor Systems

SAFETY BOLT TECHNICAL DATA


Carbon steel, zinc plated
Permissible loads for single anchors with no inuencing edge distances or spacings. Loads are calculated using partial safety factors from ETAG 001 and the characteristic anchor and installation data from this catalogue. Design calculations shall follow the requirements of ETA-06/0108. . Material: Carbon steel, Grade 8.8, zinc plated and blue passivated
Thread size Effective embedment depth (hef) Type S..., SK Permissible tension loads1) Cracked concrete M6 45 M6-10/45/ M8 55 M8-12/55/ M10 70 M10-15/70/ M12 80 M12-20/80/ M16 100 M16-25/100/ M206) 125 M20-30/125/

[mm]

Nperm

Non-cracked concrete3)

C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60

[kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN]

2.4 2.9 3.4 3.7 3.0 3.6 4.2 4.6

3.6 4.4 5.0 5.5 4.8 5.8 6.7 7.4

7.6 9.3 10.7 11.8 9.5 11.6 13.4 14.8

12.3 15.0 17.3 19.0 17.2 21.0 24.2 26.6

17.1 20.9 24.2 26.6 24.0 29.3 33.8 37.2

18.6 22.7 26.2 28.8 31.6 38.5 44.5 48.9

Permissible shear loads1) 2) Cracked concrete

Vperm

Non-cracked concrete3)

C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60

[kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN]

5.2 6.3 7.3 8.0 7.2 8.6 8.6 8.6

7.0 8.5 9.9 10.8 9.8 11.9 13.8 14.3

20.1 22.3 22.3 22.3 22.3 22.3 22.3 22.3

24.5 29.8 34.3 34.3 34.3 34.3 34.3 34.3

34.3 41.7 48.5 53.1 48.0 54.9 54.9 54.9

49.2 59.8 69.6 76.3 68.9 80.6 80.6 80.6

Spacings, edge distances and and member thicknesses Effective embedment depth Characteristic spacing4) Minimum spacing Characteristic edge distance Minimum edge distance5) Minimum member thickness Installation data Drill hole diameter Drill hole depth Clearance Through-x hole in the anchorage xture S Width across at SK S Installation torque SK Installed anchor hef scr,N smin ccr,N cmin hmin d0 h1 df sw sw Tinst Tinst
L

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [Nm] [Nm]

45 135 60 67.5 80 100

55 165 100 82.5 100 110

70 210 150 105 150 140

80 240 200 120 200 160

100 300 250 150 250 200

125 375 195 185 350 250

10 60 12 10 4 8 12

12 70 14 13 5 20 20

15 85 17 17 6 60 60

20 100 21 19 8 90 90 Countersunk washer

25 125 26 24 10 170 190

30 150 32 32 300 -

sw

Tinst

C-SL-2009E 2009 SIMPSON STRONG-TIE

d0

Size
h ef h1 h min

[mm]

[mm]

[mm]

tfix

Flattening of domed washer = visual installation check

M6 M8 M10 M12 M16

20 24 27 33 50

10 12 15 19 24

5,5 6,5 7 8 14

1) The permissible loads have been calculated using the partial safety factors for resistances stated in the ETA-approval and a partial safety factor for actions of F = 1.4. The permissible loads are valid for unreinforced concrete and reinforced concrete with a rebar spacing s 15 cm and reinforced concrete with a rebar spacing s 10 cm if the rebar is 10 mm or smaller. 2) The permissible shear loads are based on a single anchor without inuencing concrete edges. For shear loads applied close to an edge (c 10 hef or 60d) concrete edge failure must be checked per ETAG 001, Annex C, design method A. 3) Concrete is considered non-cracked when the tensile stress within the concrete is L + R 0. In the absence of detailed verication R = 3 N/mm can be assumed (L equals the tensile stress within the concrete as a result of external loads, forces on anchors included). 4) For spacings smaller than the characteristic values (i.e. s scr,N ) a calculation per ETAG 001, Annex C, design method A shall be performed. For details, see ETA-06/0108. 5) The actual edge distance shall not be less than the value of cmin shown in the table. 6) Size M20 is not included in the approval.
Complete your designs more easily by downloading our LIEBIG anchor software from our home-page: www.simpson-liebig.com

df

25

Expansion Anchor Systems

SAFETY BOLT
A4 stainless steel
SAFETY BOLT B
Threaded stud with hex nut and domed washer Material: A4-80 stainless steel x Max. Depth of Fixture Drilled Hole Thickness do x h1 [mm] 10 x 60 10 x 60 10 x 60 12 x 70 12 x 70 12 x 70 15 x 85 15 x 85 15 x 85 20 x 95 20 x 95 20 x 95 25 x 125 25 x 125 30 x 150 tx [mm] 5 15 40 5 15 40 5 15 40 5 15 40 15 40 40 Fixture Hole df [mm] 12 12 12 14 14 14 17 17 17 21 21 21 26 26 32 Eff. Embedment Depth hef [mm] 45 45 45 55 55 55 70 70 70 80 80 80 100 100 125

New Type

Old Type

Order Code

Thread Size [mm] M6 M6 M6 M8 M8 M8 M10 M10 M10 M12 M12 M12 M16 M16 M20

Total Length L [mm] 70 80 105 85 95 120 100 110 135 120 130 155 160 185 205

Weight

Box Quantity [pcs] 50 50 50 25 25 25 25 25 10 10 10 10 5 5 5

B M6-10/45/5 A4 B M6-10/45/15 A4 B M6-10/45/40 A4 B M8-12/55/5 A4 B M8-12/55/15 A4 B M8-12/55/40 A4 B M10-15/70/5 A4 B M10-15/70/15 A4 B M10-15/70/40 A4 B M12-20/80/5 A4 B M12-20/80/15 A4 B M12-20/80/40 A4 B M16-25/100/15 A4 B M16-25/100/40 A4 B M20-30/125/40 A4

B 10/20 A4 B 10/35 A4 B 10/60 A4 B 12/25 A4 B 12/40 A4 B 12/65 A4 B 15/30 A4 B 15/45 A4 B 15/70 A4 B 20/35 A4 B 20/50 A4 B 20/75 A4 B 25/55 A4 B 25/80 A4 B 30/90 A4

B0610045005A4 B0610045015A4 B0610045040A4 B0812055005A4 B0812055015A4 B0812055040A4 B1015070005A4 B1015070015A4 B1015070040A4 B1220080005A4 B1220080015A4 B1220080040A4 B1625100015A4 B1625100040A4 B2030125040A4

[kg/100 pcs] 2.7 3.4 4.6 5.8 7.0 9.0 11.0 12.8 16.0 20.8 24.8 29.0 48.4 56.7 96.7

Custom lengths available on request.

SAFETY BOLT S
Hex head screw and domed washer Material: A4-70 stainless steel x Max. Depth of Fixture Drilled Hole Thickness do x h1 [mm] 10 x 60 10 x 60 12 x 70 12 x 70 15 x 85 15 x 85 20 x 95 20 x 95 tx [mm] 15 40 15 40 15 40 15 40 Fixture Hole df [mm] 12 12 14 14 17 17 21 21 Eff. Embedment Depth hef [mm] 45 45 55 55 70 70 80 80

New Type

Old Type

Order Code

Thread Size [mm] M6 M6 M8 M8 M10 M10 M12 M12

Total Length L [mm] 80 105 90 115 105 130 123 148

Weight

Box Quantity [pcs] 50 50 25 25 25 10 10 10

S M6-10/45/15 A4 S M6-10/45/40 A4 S M8-12/55/15 A4 S M8-12/55/40 A4 S M10-15/70/15 A4 S M10-15/70/40 A4 S M12-20/80/15 A4 S M12-20/80/40 A4

S 10/35 A4 S 10/60 A4 S 12/40 A4 S 12/65 A4 S 15/45 A4 S 15/70 A4 S 20/50 A4 S 20/75 A4

S0610045015A4 S0610045040A4 S0812055015A4 S0812055040A4 S1015070015A4 S1015070040A4 S1220080015A4 S1220080040A4

[kg/100 pcs] 3.4 4.6 7.0 9.0 12.8 16.0 24.8 29.0

Custom lengths available on request.

SAFETY BOLT SK
Countersunk head screw Material: A4-70 stainless steel x Max. Depth of Fixture Drilled Hole Thickness do x h1 [mm] 10 x 60 10 x 60 12 x 70 12 x 70 15 x 85 15 x 85 20 x 95 20 x 95 tx [mm] 15 40 15 40 15 40 15 40 Fixture Hole df [mm] 12 12 14 14 17 17 21 21 Eff. Embedment Depth hef [mm] 45 45 55 55 70 70 80 80
C-SL-2009E 2009 SIMPSON STRONG-TIE

New Type

Old Type

Order Code

Thread Size [mm] M6 M6 M8 M8 M10 M10 M12 M12

Total Length L [mm] 70 95 85 110 100 125 110 135

Weight

Box Quantity [pcs] 50 50 25 25 25 25 10 10

SK M6-10/45/15 A4 SK M6-10/45/40 A4 SK M8-12/55/15 A4 SK M8-12/55/40 A4 SK M10-15/70/15 A4 SK M10-15/70/40 A4 SK M12-20/80/15 A4 SK M12-20/80/40 A4

SK 10/35 A4 SK 10/60 A4 SK 12/40 A4 SK 12/65 A4 SK 15/45 A4 SK 15/70 A4 SK 20/50 A4 SK 20/75 A4

SK0610045015A4 SK0610045040A4 SK0812055015A4 SK0812055040A4 SK1015070015A4 SK1015070040A4 SK1220080015A4 SK1220080040A4

[kg/100 pcs] 3.4 4.6 7.0 9.0 12.8 16.0 24.8 29.0

Custom lengths available on request.

26

Expansion Anchor Systems

SAFETY BOLT TECHNICAL DATA


A4 stainless steel
Permissible loads for single anchors with no inuencing edge distances or spacings. Loads are calculated using partial safety factors from ETAG 001 and the characteristic anchor and installation data from this catalogue. Material: A4-80 stainless steel (Type B), A4-70 stainless steel (Type S, SK)
Thread size Effective embedment depth (hef) Type B.... S. SK Permissible tension loads1) Cracked concrete M6 45 M6-10/45/ M8 55 M8-12/55/ M10 70 M10-15/70/ M12 80 M12-20/80/ M16 100 M16-25/100/ M20 125 M20-30/125/

[mm]

Nperm

Non-cracked concrete3)

C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60

[kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN]

3.2 3.9 4.5 5.0

4.3 5.2 6.1 6.7

7.1 8.6 10.0 11.0 B 20.5 24.2 27.5 28.9 28.7 28.9 28.9 28.9

7.1 8.4 9.5 10.5 10.7 12.6 14.3 15.8 S/SK 20.5 24.2 24.6 24.6 24.6 24.6 24.6 24.6 B 28.6 33.7 38.3 42.3 40.0 47.2 49.5 49.5

10.7 12.6 14.3 15.8 16.0 18.8 21.4 23.7 S/SK 28.6 33.7 38.3 41.5 40.0 41.5 41.5 41.5 B 39.9 47.1 53.5 59.1 55.9 66.0 67.4 67.4

15.5 18.3 20.8 22.9 23.2 27.4 31.1 34.3 S/SK 39.9 47.1 53.5 59.1 55.9 61.6 61.6 61.6

Permissible shear loads1) 2) Cracked concrete

Vperm

Non-cracked concrete3)

C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60

[kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN]

3.2 3.9 4.5 5.0

4.3 5.2 6.1 6.7

7.1 8.6 10.0 11.0

Permissible bending moments1)4) Mperm

[Nm]

6.5

16.1

32.1

56.1

142.7

278.1

Spacings, edge distances and and member thicknesses [mm] Effective embedment depth hef scr, N [mm] Characteristic spacing5) [mm] Minimum spacing smin [mm] Characteristic edge distance ccr, N cmin [mm] Minimum edge distance6) [mm] Minimum member thickness hmin Installation data Drill hole diameter Drill hole depth Through-x Clearance anchorage hole in the Installation on xture threaded stud Width across at B S SK B S SK d0 h1 df df sw sw sw Tinst Tinst Tinst [mm] [mm] [mm] [mm] [mm] [mm] [mm] [Nm] [Nm] [Nm]

45 140 140 80 80 100

55 165 165 120 120 110

70 235 235 165 165 140

80 240 120 120 210 150

100 300 150 150 270 200

125 375 195 195 350 250

10 60 12 7 10 10 4 10 10 10

12 70 14 9 13 13 5 25 25 25

15 85 17 12 17 17 6 50 50 50

20 95 21 14 19 19 8 80 80 80

25 125 26 18 24 180 -

30 150 32 22 30 300 -

Installation torque Installed anchor


C-SL-2009E 2009 SIMPSON STRONG-TIE

Countersunk washer

Size M6 M8 M10 M12

Flattening of domed washer = visual installation check

D [mm] 20 24 27 33

d [mm] 10 12 15 19

k [mm] 5,5 6,5 7 8

1) The permissible loads have been calculated using partial safety factors for resistances and a partial safety factor for actions of F = 1.4. The permissible loads are valid for unreinforced concrete and reinforced concrete with a rebar spacing s 15 cm and reinforced concrete with a rebar spacing s 10 cm if the rebar is 10 mm or smaller. 2) The permissible shear loads are based on a single anchor without inuencing concrete edges. For shear loads applied close to an edge (c 10 hef or 60d) concrete edge failure must be checked per ETAG 001, Annex C, design method A. 3) Concrete is considered non-cracked when the tensile stress within the concrete is L + R 0. In the absence of detailed verication R = 3 N/mm can be assumed (L equals the tensile stress within the concrete as a result of external loads, forces on anchors included). 4) The permissible bending moments are only valid for the threaded stud (e.g. in case of a distance mounting). 5) For spacings smaller than the characteristic values (i.e. s scr,N ) a calculation per ETAG 001, Annex C, design method A shall be performed. 6) The actual edge distance shall not be less than the value of cmin shown in the table. Complete your designs more easily by downloading our LIEBIG anchor software from our home-page: www.simpson-liebig.com

27

LIEBIG ANCHOR
General purpose heavy duty anchor.

Type AB

Type AS

Function: Application of the installation torque draws the anchors cone into the thick-walled expansion sleeve. This causes the sleeve to be pressed against the sidewalls of the hole and develops tension resistance through friction. Benefits: Economical high capacity anchor Approved for use in cracked and non-cracked concrete.

28

C-SL-2009E 2009 SIMPSON STRONG-TIE

Expansion Anchor Systems

LIEBIG ANCHOR
CONSTRUCTION: AB AS with hex nut, domed washer and and threaded stud with hex head screw and domed washer

MATERIAL:

R 120

Grade 8.8 carbon steel, zinc plated and blue passivated A4-80 stainless steel (Type AB), A4-70 stainless steel (Type AS) BASE MATERIAL: Cracked and non-cracked concrete: C20/25 to C50/60 APPROVAL: ETA-06/0123 Option 1 Carbon steel, zinc plated LOAD RANGE: Tension: Shear: PRODUCT RANGE: AB: M6 - M16, carbon steel, zinc plated and blue passivated / A4 stainless steel AS: M6 - M16, carbon steel, zinc plated and blue passivated / M6 - M12, A4 stainless steel APPLICATIONS: Steel construction Railing Gates Lifting systems BENEFITS: Economical anchor for wide range of uses Torque indication from domed washer PRODUCT DESCRIPTION: Heavy duty anchor for high loads Torque-controlled mechanical anchor INSTALLATION: Through-fix installation Cable trays Machines Facades Base plates Nperm = 2.4 - 37.2 [kN] Vperm = 5.2 - 54.9 [kN]

C-SL-2009E 2009 SIMPSON STRONG-TIE

90

Drill hole

Clean hole (blowing)

Insert anchor through fixture

Apply recommended fastening torque with a calibrated torque-wrench

29

Expansion Anchor Systems

LIEBIG ANCHOR
Carbon steel, zinc plated
LIEBIG ANCHOR AB
Threaded stud with hex nut and domed washer Material: Grade 8.8 carbon steel, zinc plated and blue passivated Approval: ETA-06/0123 Option 1 ThreadSize Depth Max. Fixture of Drilled Fixture Hole Hole Thickness do x h1 [mm] AB M6-10/45/5 AB M6-10/45/15 AB M6-10/45/40 AB M8-12/55/5 AB M8-12/55/15 AB M8-12/55/40 AB M8-12/55/65 AB M8-12/55/100 AB M10-15/65/5 AB M10-15/65/15 AB M10-15/65/40 AB M10-15/65/65 AB M10-15/65/100 AB M12-20/80/5 AB M12-20/80/15 AB M12-20/80/40 AB M12-20/80/65 AB M12-20/80/100 AB M16-25/100/5 AB M16-25/100/15 AB M16-25/100/40 AB M16-25/100/65 AB M16-25/100/100 AB 10/0 AB 10/15 AB 10/40 AB 12/0 AB 12/15 AB 12/40 AB 12/65 AB 15/0 AB 15/15 AB 15/40 AB 15/65 AB 20/0 AB 20/15 AB 20/40 AB 20/65 AB 25/0 AB 25/15 AB 25/40 AB 25/65 LAB0610045005 LAB0610045015 LAB0610045040 LAB0812055005 LAB0812055015 LAB0812055040 LAB0812055065 LAB0812055100 LAB1015065005 LAB1015065015 LAB1015065040 LAB1015065065 LAB1015065100 LAB1220080005 LAB1220080015 LAB1220080040 LAB1220080065 LAB1220080100 LAB1625100005 LAB1625100015 LAB1625100040 LAB1625100065 LAB1625100100 M6 M6 M6 M8 M8 M8 M8 M8 M10 M10 M10 M10 M10 M12 M12 M12 M12 M12 M16 M16 M16 M16 M16 [mm] 10 x 60 10 x 60 10 x 60 12 x 70 12 x 70 12 x 70 12 x 70 12 x 70 15 x 85 15 x 85 15 x 85 15 x 85 15 x 85 20 x 100 20 x 100 20 x 100 20 x 100 20 x 100 25 x 125 25 x 125 25 x 125 25 x 125 25 x 125 tx [mm] 5 15 40 5 15 40 65 100 5 15 40 65 100 5 15 40 65 100 5 15 40 65 100 df [mm] 12 12 12 14 14 14 14 14 17 17 17 17 17 21 21 21 21 21 26 26 26 26 26 Eff. Embedment Depth hef [mm] 45 45 45 55 55 55 55 55 65 65 65 65 65 80 80 80 80 80 100 100 100 100 100 Total Length L [mm] 70 80 105 85 95 120 145 180 100 110 135 160 195 120 130 155 180 215 150 160 185 210 245 [kg/100 pcs] 2.7 3.4 4.6 5.8 7.0 9.0 10.6 12.8 11.0 12.8 16.0 18.5 22.0 20.8 24.8 29.0 33.5 39.8 43.4 48.4 56.7 63.6 73.3 [pcs] 50 50 50 25 25 25 25 25 25 25 10 10 10 10 10 10 10 20 5 5 5 10 10

New Type

Old Type

Order Code

Weight

Box Quantity

Custom lengths available on request.

LIEBIG ANCHOR AS
Hex head screw and domed washer Material: Grade 8.8 carbon steel, zinc plated and blue passivated Approval: ETA-06/0123 Option 1 ThreadSize Depth Max. Fixture of Drilled Fixture Hole Hole Thickness do x h1 [mm] AS M6-10/45/5 AS M6-10/45/15 AS M6-10/45/40 AS M8-12/55/5 AS M8-12/55/15 AS M8-12/55/40 AS M10-15/65/5 AS M10-15/65/15 AS M10-15/65/40 AS M12-20/80/5 AS M12-20/80/15 AS M12-20/80/40 AS M16-25/100/15 AS M16-25/100/40 30 AS 10/0 AS 10/15 AS 10/40 AS 12/0 AS 12/15 AS 12/40 AS 15/0 AS 15/15 AS 15/40 AS 20/0 AS 20/15 AS 20/40 AS 25/15 AS 25/40 LAS0610045005 LAS0610045015 LAS0610045040 LAS0812055005 LAS0812055015 LAS0812055040 LAS1015065005 LAS1015065015 LAS1015065040 LAS1220080005 LAS1220080015 LAS1220080040 LAS1625100015 LAS1625100040 M6 M6 M6 M8 M8 M8 M10 M10 M10 M12 M12 M12 M16 M16 [mm] 10 x 60 10 x 60 10 x 60 12 x 70 12 x 70 12 x 70 15 x 85 15 x 85 15 x 85 20 x 100 20 x 100 20 x 100 25 x 125 25 x 125 tx [mm] 5 15 40 5 15 40 5 15 40 5 15 40 15 40 df [mm] 12 12 12 14 14 14 17 17 17 21 21 21 26 26 Eff. Embedment Depth hef [mm] 45 45 45 55 55 55 65 65 65 80 80 80 100 100 Total Length L [mm] 70 80 105 80 90 115 95 105 130 113 123 148 155 180 [kg/100 pcs] 2.7 3.4 4.6 5.8 7.0 9.0 11.0 12.8 16.0 20.8 24.8 29.0 48.4 56.7 [pcs] 50 50 50 25 25 25 25 25 10 10 10 10 5 5

New Type

Old Type

Order Code

Weight

Box Quantity

Custom lengths available on request.

C-SL-2009E 2009 SIMPSON STRONG-TIE

Expansion Anchor Systems

LIEBIG ANCHOR TECHNICAL DATA


Carbon steel, zinc plated
Permissible loads for single anchors with no inuencing edge distances or spacings. Loads are calculated using partial safety factors from ETAG 001 and the characteristic anchor and installation data from this catalogue. Design calculations shall follow the requirements of ETA-06/0123. Material: Carbon steel, Grade 8.8, zinc plated and blue passivated
Thread size Effective embedment depth (hef) Type AB..., AS... Permissible tension loads1) Cracked conctrete M6 45 M6-10/45/ M8 55 M8-12/55/ M10 65 M10-15/65/ M12 80 M12-20/80/ M16 100 M16-25/100/

[mm]

Nperm

Non-cracked concrete3)

C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60

[kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN]

2.4 2.9 3.4 3.7 3.0 3.6 4.2 4.6

3.6 4.4 5.0 5.5 4.8 5.8 6.7 7.4

7.6 9.3 10.7 11.8 9.5 11.6 13.4 14.8

12.3 15.0 17.3 19.0 17.1 20.9 24.2 26.6

17.1 20.9 24.2 26.6 24.0 29.3 33.8 37.2

Permissible shear loads1) 2) Cracked conctrete

Vperm

Non-cracked concrete3)

C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60

[kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN]

5.2 6.3 7.3 8.0 7.2 8.6 8.6 8.6

7.0 8.5 9.9 10.8 9.8 11.9 13.8 14.3

18.0 21.9 22.3 22.3 22.3 22.3 22.3 22.3

24.5 29.8 34.3 34.3 34.3 34.3 34.3 34.3

34.3 41.7 48.5 53.1 48.0 54.9 54.9 54.9

Permissible bending moments1) 4) Mperm4)

[Nm]

6.9

17.1

34.3

60

152

Spacings, edge distances and and member thicknesses hef [mm] Effective embedment depth scr,N [mm] Characteristic spacing5) smin [mm] Minimum spacing ccr,N [mm] Characteristic edge distance cmin [mm] Minimum edge distance6) hmin [mm] Minimum member thickness Installation data Drill hole diameter Drill hole depth Clearance Through-x hole in the anchorage xture Installation on threaded stud Width across ats Installation torque AB AS AB AS

45 135 60 67.5 80 100

55 165 80 82.5 100 110

65 195 130 97.5 130 130

80 240 200 120 200 160

100 300 300 150 300 200

d0 h1 df df sw sw Tinst Tinst

[mm] [mm] [mm] [mm] [mm] [mm] [Nm] [Nm]

10 60 12 7 10 10 7 8

12 70 14 9 13 13 15 20

15 85 17 12 17 17 30 50

20 100 21 14 19 19 50 75

25 125 26 18 24 24 115 170

Installed anchor
C-SL-2009E 2009 SIMPSON STRONG-TIE

Flattening of domed washer = visual installation check

1) The permissible loads have been calculated using the partial safety factors for resistances stated in the ETA-approval and a partial safety factor for actions of F = 1.4. The permissible loads are valid for unreinforced concrete and reinforced concrete with a rebar spacing s 15 cm and reinforced concrete with a rebar spacing s 10 cm if the rebar is 10 mm or smaller. 2) The permissible shear loads are based on a single anchor without inuencing concrete edges. For shear loads applied close to an edge (c 10 hef or 60d) concrete edge failure must be checked per ETAG 001, Annex C, design method A. 3) Concrete is considered non-cracked when the tensile stress within the concrete is L + R 0. In the absence of detailed verication R = 3 N/mm can be assumed (L equals the tensile stress within the concrete as a result of external loads, forces on anchors included). 4) The permissible bending moments are only valid for the threaded stud type AB (e.g. in case of a distance mounting). 5) For spacings smaller than the characteristic values ((i.e. s scr,N) a calculation per ETAG 001, Annex C, design method A shall be performed. 6) The actual edge distance shall not be less than the value of cmin shown in the table. Complete your designs more easily by downloading our LIEBIG anchor software from our home-page: www.simpson-liebig.com

31

Expansion Anchor Systems

LIEBIG ANCHOR
A4 stainless steel
LIEBIG ANCHOR AB
Threaded stud with hex nut and domed washer Material: A4-80 stainless steel ThreadSize Depth Max. Eff. Fixture Total of Drilled Fixture Embedment Hole Length Hole Thickness Depth do x h1 [mm] AB M6-10/45/5 A4 AB M6-10/45/15 A4 AB M6-10/45/40 A4 AB M8-12/55/5 A4 AB M8-12/55/15 A4 AB M8-12/55/40 A4 AB M10-15/65/5 A4 AB M10-15/65/15 A4 AB M10-15/65/40 A4 AB M12-20/80/5 A4 AB M12-20/80/15 A4 AB M12-20/80/40 A4 AB 10/0 A4 AB 10/15 A4 AB 10/40 A4 AB 12/0 A4 AB 12/15 A4 AB 12/40 A4 AB 15/0 A4 AB 15/15 A4 AB 15/40 A4 AB 20/0 A4 AB 20/15 A4 AB 20/40 A4 AB0610045005A4 AB0610045015A4 AB0610045040A4 AB0812055005A4 AB0812055015A4 AB0812055040A4 AB1015065005A4 AB1015065015A4 AB1015065040A4 AB1220080005A4 AB1220080015A4 AB1220080040A4 AB1625100015A4 AB1625100040A4 M6 M6 M6 M8 M8 M8 M10 M10 M10 M12 M12 M12 M16 M16 [mm] 10 x 60 10 x 60 10 x 60 12 x 70 12 x 70 12 x 70 15 x 85 15 x 85 15 x 85 20 x 95 20 x 95 20 x 95 25 x 125 25 x 125 tx [mm] 5 15 40 5 15 40 5 15 40 5 15 40 15 40 df [mm] 12 12 12 14 14 14 17 17 17 21 21 21 26 26 hef [mm] 45 45 45 55 55 55 65 65 65 80 80 80 100 100 L [mm] 70 80 105 85 95 120 100 110 135 120 130 155 160 185 [kg/100 pcs] 2.9 3.4 4.6 6.2 7.0 9.0 11.5 12.8 16.0 25.1 24.8 29.0 48.4 56.7 [pcs] 50 50 50 25 25 25 25 25 10 10 10 10 5 5

New Type

Old Type

Order Code

Weight

Box Quantity

AB M16-25/100/15 A4 AB 25/15 A4 AB M16-25/100/40 A4 AB 25/40 A4


Custom lengths available on request.

LIEBIG ANCHOR AS
Hex head screw and domed washer Material: A4-70 stainless steel ThreadSize Depth Max. Eff. Fixture Total of Drilled Fixture Embedment Hole Length Hole Thickness Depth do x h1 [mm] AS M6-10/45/5 A4 AS M6-10/45/15 A4 AS M8-12/55/15 A4 AS M8-12/55/40 A4 AS M10-15/65/15 A4 AS M10-15/65/40 A4 AS M12-20/80/15 A4 AS M12-20/80/40 A4 AS 10/0 A4 AS 10/15 A4 AS 12/15 A4 AS 12/40 A4 AS 15/15 A4 AS 15/40 A4 AS 20/15 A4 AS 20/40 A4 AS0610045005A4 AS0610045015A4 AS0812055015A4 AS0812055040A4 AS1015065015A4 AS1015065040A4 AS1220080015A4 AS1220080040A4 M6 M6 M8 M8 M10 M10 M12 M12 [mm] 10 x 60 10 x 60 12 x 70 12 x 70 15 x 85 15 x 85 20 x 95 20 x 95 tx [mm] 5 15 15 40 15 40 15 40 df [mm] 12 12 14 14 17 17 21 21 hef [mm] 45 45 55 55 65 65 80 80 L [mm] 70 80 90 115 105 130 123 148 [kg/100 pcs] 2.9 3.4 7.0 9.0 12.8 16.0 24.8 29.0 [pcs] 50 50 25 25 25 10 10
C-SL-2009E 2009 SIMPSON STRONG-TIE

New Type

Old Type

Order Code

Weight

Box Quantity

10

Custom lengths available on request.

32

Expansion Anchor Systems

LIEBIG ANCHOR TECHNICAL DATA


A4 stainless steel
Permissible loads for single anchors with no inuencing edge distances or spacings. Loads are calculated using partial safety factors from ETAG 001 and the characteristic anchor and installation data from this catalogue.
Material: A4 Stainless steel Thread size Effective embedment depth (hef) Type AB..., AS... Permissible tension loads1) Cracked concrete M6 45 M6-10/45/ M8 55 M8-12/55/ M10 65 M10-15/65/ M12 80 M12-20/80/ M16 100 M16-25/100/

[mm]

Nperm

Non-cracked concrete3)

C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60

[kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN]

3.2 3.9 4.5 5.0

4.3 5.2 6.1 6.7

7.1 8.6 10.0 11.0 AB 20.5 24.2 27.5 28.9 28.7 28.9 28.9 28.9

7.1 8.4 9.5 10.5 10.7 12.6 14.3 15.8 AS 20.5 24.2 24.6 24.6 24.6 24.6 24.6 24.6 AB 28.6 33.7 38.3 42.3 40.0 47.2 49.5 49.5

10.7 12.6 14.3 15.8 16.0 18.8 21.4 23.7 AS 28.6 33.7 38.3 41.5 40.0 41.5 41.5 41.5

Permissible shear loads1) 2) Cracked concrete

Vperm

Non-cracked concrete3)

C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60

[kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN]

3.2 3.9 4.5 5.0

4.3 5.2 6.1 6.7

7.1 8.6 10.0 11.0

Permissible bending moments1) 4) Mperm4)

[Nm]

6.5

16.1

32.1

56.1

142.7

Spacings, edge distances and and member thicknesses hef [mm] Effective embedment depth scr, N [mm] Characteristic spacing5) smin [mm] Minimum spacing ccr, N [mm] Characteristic edge distance cmin [mm] Minimum edge distance6) hmin [mm] Minimum member thickness Installation data Drill hole diameter Drill hole depth Clearance Through-x hole in the anchorage xture Installation on threaded stud Width across ats AB, AS Installation torque AB, AS Installed anchor

45 140 140 80 80 100

55 165 165 120 120 110

65 235 235 165 165 130

80 240 80 120 160 150

100 300 100 150 200 200

d0 h1 df df sw Tinst

[mm] [mm] [mm] [mm] [mm] [Nm]

10 60 12 7 10 10

12 70 14 9 13 25

15 85 17 12 17 50

20 95 21 14 19 80

25 125 26 18 24 180

C-SL-2009E 2009 SIMPSON STRONG-TIE

Flattening of domed washer = visual installation check

1) The permissible loads have been calculated using the partial safety factors for resistances stated in the ETA-approval and a partial safety factor for actions of F = 1.4. The permissible loads are valid for unreinforced concrete and reinforced concrete with a rebar spacing s 15 cm and reinforced concrete with a rebar spacing s 10 cm if the rebar is 10 mm or smaller. 2) The permissible shear loads are based on a single anchor without inuencing concrete edges. For shear loads applied close to an edge (c 10 hef or 60d) concrete edge failure must be checked per ETAG 001, Annex C, design method A. 3) Concrete is considered non-cracked when the tensile stress within the concrete is L + R 0. In the absence of detailed verication R = 3 N/mm can be assumed (L equals the tensile stress within the concrete as a result of external loads, forces on anchors included). 4) The permissible bending moments are only valid for the threaded stud type AB (e.g. in case of a distance mounting). 5) For spacings smaller than the characteristic values ((i.e. s scr,N) a calculation per ETAG 001, Annex C, design method A shall be performed. 6) The actual edge distance shall not be less than the value of cmin shown in the table. Complete your designs more easily by downloading our LIEBIG anchor software from our home-page: www.simpson-liebig.com

33

THROUGHBOLT BOA-X AND BOAX-II


For simple and economical applications.

Function: Application of the installation torque draws the cone end of the stud into the expansion clip. The expansion clip expands and develops a frictional grip with the sidewalls of the hole. This gives the anchor its resistance to tension loads. Benefits: Economical anchor for medium-duty loads Approved for use in cracked and non-cracked concrete

34

C-SL-2009E 2009 SIMPSON STRONG-TIE 2009

Expansion Anchor Systems

BOA-X AND BOAX-II


CONSTRUCTION:

BoA-X / BoAX-II

with hex nut and washer

MATERIAL: Carbon steel, zinc plated and blue passivated A4 stainless steel BASE MATERIAL:

R 120

Cracked and non-cracked concrete: C20/25 to C50/60 Also suitable for high density natural stones (D 25 N/mm2) APPROVALS: ETA-08/0276 - Option 1: M8-M16, carbon steel, zinc plated ETA-04/0058 - Option 4: M8-M16, A4 stainless steel LOAD RANGE: Tension: Shear: Nperm = 1.8 - 21.4 [kN] Vperm = 1.8 - 21.0 [kN]

PRODUCT RANGE: BoAX-II: M8 - M16, carbon steel, zinc plated and blue passivated BoA-X: M6 + M20, carbon steel, zinc plated and blue passivated BoA-X A4: M6 - M20, A4 stainless steel APPLICATIONS: Steel construction Railing Brackets BENEFITS: Economical anchor for medium duty loads Less drilling effort: Anchor diameter = Drill bit diameter PRODUCT DESCRIPTION: The throughbolt anchor is installed through the xture Torquing draws the cone end of the stud into the expansion clip. The expansion clip expands and develops a frictional grip with the sidewalls of the hole. INSTALLATION: Through-fix installation
C-SL-2009E 2009 SIMPSON STRONG-TIE

Facades Cable trays Ladders

90

Drill hole

Clean hole (blowing)

Insert anchor through fixture

Apply recommended fastening torque with a calibrated torque-wrench

When many anchors are to be installed, setting tools BoA-ST M6-M10 and BoA-ST M12-M20 are recommended to make the job easier. 35

Expansion Anchor Systems

BOA-X AND BOAX-II


Carbon steel, zinc plated
THROUGHBOLT BOA-X AND BOAX-II
With hex nut and washer Material: Carbon steel, zinc plated and blue passivated Approval: ETA-08/0276 - Option 1 Thread Size x Depth of Drilled Hole do x h1 [mm] BoA-X 6/15 BoA-X 6/50* BoAX-II 8/10 BoAX-II 8/30 BoAX-II 8/50 BoAX-II 8/85 BoAX-II 10/10 BoAX-II 10/20 BoAX-II 10/30 BoAX-II 10/50 BoAX-II 10/80 BoAX-II 12/5 BoAX-II 12/20 BoAX-II 12/30 BoAX-II 12/50 BoAX-II 12/65 BoAX-II 12/80 BoAX-II 16/5 BoAX-II 16/20 BoAX-II 16/50 BoAX-II 16/60 BoA-X 16/95
* *

Type

Order Code

Max. Fixture Thickness tx [mm] 15 50 10 30 50 85 10 20 30 50 80 5 20 30 50 65 80 5 20 50 60 95 20 70 130

Fixture Hole df [mm] 7 7 9 9 9 9 12 12 12 12 12 14 14 14 14 14 14 18 18 18 18 18 22 22 22

Eff. Embedment Depth hef [mm] 35 35 45 45 45 45 60 60 60 60 60 70 70 70 70 70 70 85 85 85 85 85 110 110 110

Total Length L [mm] 65 100 72 92 112 147 92 102 112 132 162 103 118 128 148 163 178 123 138 168 178 213 170 220 280

Thread Length f [mm] 28 28 32 52 72 107 47 57 67 87 115 53 68 78 98 113 115 65 80 110 115 55 55 55 55

Weight

Box Quantity

[mm] 6 x 50 6 x 50 8 x 60 8 x 60 8 x 60 8 x 60 10 x 75 10 x 75 10 x 75 10 x 75 10 x 75 12 x 90 12 x 90 12 x 90 12 x 90 12 x 90 12 x 90 16 x 110 16 x 110 16 x 110 16 x 110 16 x 110 20 x 130 20 x 130 20 x 130

[kg/100 pcs] 1.54 2.27 2.91 3.53 4.14 5.21 5.92 6.41 6.91 7.89 9.37 9.53 10.60 11.31 12.73 13.80 14.87 20.16 22.17 26.19 27.53 35.01 44.83 57.02 71.78

[pcs] 100 100 50 50 40 40 40 25 25 25 25 20 20 20 20 20 20 10 10 10 10 10 5 5 5

BOAX0606035015 BOAX0606035050 BOAXII08045010 BOAXII08045030 BOAXII08045050 BOAXII08045085 BOAXII10060010 BOAXII10060020 BOAXII10060030 BOAXII10060050 BOAXII10060080 BOAXII12070005 BOAXII12070020 BOAXII12070030 BOAXII12070050 BOAXII12070065 BOAXII12070080 BOAXII16085005 BOAXII16085020 BOAXII16085050 BOAXII16085060 BOAX1616085095 BOAX2020110020 BOAX2020110070 BOAX2020110130

M6 M6 M8 M8 M8 M8 M10 M10 M10 M10 M10 M12 M12 M12 M12 M12 M12 M16 M16 M16 M16 M16 M20 M20 M20

BoA-X 20/20* BoA-X 20/70* BoA-X 20/130*

*Not included in approval.

Setting Tool BoA-ST


The setting tool is recommended for applications where many BoA-X or BoAX-II anchors are to be installed.

Type

Order Code

Weight [kg/100 pcs]

Box Quantity [pc] 1 1

BoA-ST M6 - M10 BoA-ST M12 - M20

BOASTM06M10 BOASTM12M20

6.0 9.0

36

C-SL-2009E 2009 SIMPSON STRONG-TIE

Expansion Anchor Systems

BOA-X AND BOAX-II


Carbon steel, zinc plated

TECHNICAL DATA

Permissible loads for single anchors with no inuencing edge distances or spacings. Loads are calculated using partial safety factors from ETAG 001 and the characteristic anchor and installation data from this catalogue. Design calculations shall follow the requirements of ETA-08/0276. Material: Carbon steel, zinc plated and blue passivated
Thread size Effective embedment depth (hef) Type BoA-... Permissible tension loads1) Cracked Concrete M65) 35 BoA-X 6/ M8 45 BoAX-II 8/ M10 60 BoAX-II 10/ M12 70 BoAX-II 12/ M166) 85 BoAX-II 16/ M205) 110 BoA-X 20/

[mm]

Nperm

Non-cracked concrete3)

C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60

[kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN]

1.8 1.8 1.8 1.8

2.0 2.2 2.4 2.6 3.6 3.9 4.3 4.6

3.6 4.0 4.3 4.6 6.3 6.9 7.6 8.1

4.8 5.3 5.8 6.1 7.9 8.7 9.5 10.1

9.5 10.5 11.4 12.2 16.7 18.4 20.0 21.4

13.9 13.9 13.9 13.9

Permissible shear loads1) 2) Cracked Concrete

Vperm

Non-cracked concrete3)

C20/25 C30/37 C40/50 C50/60 C20/25 C30/37 C40/50 C50/60

[kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN]

1.8 1.8 1.8 1.8

4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8

8.7 8.7 8.7 8.7 8.7 8.7 8.7 8.7

11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0

21.0 21.0 21.0 21.0 21.0 21.0 21.0 21.0

13.9 13.9 13.9 13.9

Permissible bending moments1) Mzul4)

[Nm]

4.1

10.0

22.9

34.3

88.6

173.0

Spacings, edge distances and member thicknesses hef [mm] Effective embedment depth scr,N [mm] Characteristic spacing4) smin [mm] Minimum spacing [mm] Characteristic edge distance4) ccr,N cmin [mm] Minimum edge distance [mm] Minimum member thickness hmin Installation data Drill hole diameter Drill hole depth Clearance hole in the xture Width across ats Installation torque Installed anchor

35 120 120 90 90 60

45 135 50 68 50 100

60 180 55 90 50 120

70 210 60 105 55 140

85 255 70 128 85 170

110 400 400 300 300 180

d0 h1 df sw Tinst

[mm] [mm] [mm] [mm] [Nm]

6 50 7 10 7

8 60 9 13 20
L

10 75 12 17 35

12 90 14 19 50

16 110 18 24 120

20 130 22 30 240

sw Tinst
d0
C-SL-2009E 2009 SIMPSON STRONG-TIE

h1 h min

1) The permissible loads have been calculated using the partial safety factors for resistances stated in the ETA-approval and a partial safety factor for actions of F = 1.4. The permissible loads are valid for unreinforced concrete and reinforced concrete with a rebar spacing s 15 cm and reinforced concrete with a rebar spacing s 10 cm if the rebar is 10 mm or smaller. 2) The permissible shear loads are based on a single anchor without inuencing concrete edges. For shear loads applied close to an edge (c < 10 hef or < 60 d) concrete edge failure must be checked per ETAG 001, Annex C, design method A. 3) Concrete is considered non-cracked when the tensile stress within the concrete is L + R 0. In the absence of detailed verication R = 3 N/mm2 can be assumed (L equals the tensile stress within the concrete as a result of external loads, forces on anchors included). 4) If spacings or edge distances become smaller than the characteristic values (i.e. s scr,N and/or c ccr,N) a calculation per ETAG 001, Annex C, design method A must be performed. For details, see ETA-08/0276. 5) Not included in the approval ETA-08/0276. 6) Type BoA-X 16/95 is not included in ETA-08/0276. Permissible loads in C20/25 to C50/60 cracked concrete: Nperm = 6.4 [kN] ; Vperm = 6,4 [kN]. Permissible loads in C20/25 to C50/60 non-cracked concrete: Nperm = 10.0 [kN] ; Vperm = 10.0 [kN]. Complete your designs more easily by downloading our LIEBIG anchor software from our home-page: www.simpson-liebig.com

df

h ef

t fix

37

Expansion Anchor Systems

BOA-X AND BOAX-II


A4 stainless steel
THROUGHBOLT BOA-X-A4
With hex nut and washer Material: A4 stainless steel Approval: ETA-04/0058 - Option 4 Thread Size x Depth of Drilled Hole do x h1 [mm] BoA-X 6/15 A4
*

Type

Order Code

Max. Fixture Thickness tx [mm] 15 10 30 55 10 20 30 55 5 10 20 35 65 5 20 45 20 70

Fixture Hole df [mm] 7 9 9 9 12 12 12 12 14 14 14 14 14 18 18 18 22 22

Eff. Embedment Depth hef [mm] 35 50 50 50 50 50 50 50 60 60 60 60 60 80 80 80 110 110

Total Length L [mm] 65 75 95 120 80 90 100 125 85 90 100 115 145 110 125 150 170 220

Thread Length f [mm] 28 32 41 66 34 44 54 67 35 40 50 52 82 53 65 76 55 55

Weight

Box Quantity

[mm] 6 x 50 8 x 65 8 x 65 8 x 65 10 x 70 10 x 70 10 x 70 10 x 70 12 x 80 12 x 80 12 x 80 12 x 80 12 x 80 16 x 105 16 x 105 16 x 105 20 x 130 20 x 130

[kg/100 pcs] 1.54 2.95 3.61 4.35 5.32 5.80 6.28 7.59 8.17 8.50 9.23 10.38 12.47 18.57 20.46 23.90 44.83 57.02

[pcs] 150 50 50 50 50 50 25 25 25 25 25 25 25 10 10 10 5 5

BOAX0606035015A4 BOAX0808050010A4 BOAX0808050030A4 BOAX0808050055A4 BOAX1010050010A4 BOAX1010050020A4 BOAX1010050030A4 BOAX1010050055A4 BOAX1212060005A4 BOAX1212060010A4 BOAX1212060020A4 BOAX1212060035A4 BOAX1212060065A4 BOAX1616080005A4 BOAX1616080020A4 BOAX1616080045A4 BOAX2020110020A4 BOAX2020110070A4

M6 M8 M8 M8 M10 M10 M10 M10 M12 M12 M12 M12 M12 M16 M16 M16 M20 M20

BoA-X 8/10 A4 BoA-X 8/30 A4 BoA-X 8/55 A4 BoA-X 10/10 A4 BoA-X 10/20 A4 BoA-X 10/30 A4 BoA-X 10/55 A4 BoA-X 12/5 A4 BoA-X 12/10 A4 BoA-X 12/20 A4 BoA-X 12/35 A4 BoA-X 12/65 A4 BoA-X 16/5 A4 BoA-X 16/20 A4 BoA-X 16/45 A4 BoA-X 20/20 A4* BoA-X 20/70 A4*

*Not included in approval.

Setting Tool BoA-ST


The setting tool is recommended for applications where many BoA-X or BoAX-II anchors are to be installed.

Type

Order Code

Weight [kg/100 pcs]

Box Quantity [pc] 1 1

BoA-ST M6 - M10 BoA-ST M12 - M20

BOASTM06M10 BOASTM12M20

6.0 9.0

38

C-SL-2009E 2009 SIMPSON STRONG-TIE

Expansion Anchor Systems

BOA-X AND BOAX-II


A4 stainless steel

TECHNICAL DATA

Permissible loads for single anchors with no inuencing edge distances or spacings. Loads are calculated using partial safety factors from ETAG 001 and the characteristic anchor and installation data from this catalogue. Design calculations shall follow the requirements of ETA-04/0058.
Material: A4 stainless steel Thread size Effective embedment depth (hef) Type BoA-... [mm] M64) 35 BoA-X 6/ M8 50 BoA-X 8/ M10 50 BoA-X 10/ M12 60 BoA-X 12/ M16 80 BoA-X 16/ M204) 110 BoA-X 20/

Permissible tension loads1) in any action directions for concrete C20/25 to C50/60StahlA4StahlA4StahlA4StahlA4StaA4

Fperm

Cracked Concrete Non-cracked concrete2)

[kN] [kN]

1.8

2.0 2.4

3.0 3.6

4.8 6.4

6.4 9.9

13.9

Permissible bending moments1) Mperm [Nm] 4.4 10.7 21.3 37.4 95.2 185.4

Spacings, edge distances and and member thicknesses Effective embedment depth Characteristic spacing3) Minimum spacing Characteristic edge distance3) Minimum edge distance Minimum member thickness Installation data Drill hole diameter Drill hole depth Clearance hole in the xture Width across ats Installation torque Installed anchor d0 h1 df sw Tinst [mm] [mm] [mm] [mm] [Nm] 6 50 7 10 7 8 65 9 13 18
L f

hef scr smin ccr cmin hmin

[mm] [mm] [mm] [mm] [mm] [mm]

35 120 120 90 90 60

50 250 70 125 50 100

50 250 120 125 55 100

60 300 150 150 65 120

80 400 185 200 95 160

110 400 400 300 300 180

10 70 12 17 30

12 80 14 19 54

16 105 18 24 120

20 130 22 30 240

sw Tinst
d0

h1 h min

C-SL-2009E 2009 SIMPSON STRONG-TIE

1) The permissible loads have been calculated using the partial safety factors for resistances stated in the ETA-approval and a partial safety factor for actions of F = 1.4. The permissible loads are valid for unreinforced concrete and reinforced concrete with a rebar spacing s 15 cm and reinforced concrete with a rebar spacing s 10 cm if the rebar is 10 mm or smaller. 2) Concrete is considered non-cracked when the tensile stress within the concrete is L + R 0. In the absence of detailed verication R = 3 N/mm2 can be assumed (L equals the tensile stress within the concrete as a result of external loads, forces on anchors included). 3) If spacings or edge distances become smaller than the characteristic values (i.e. s scr and/or c ccr) a calculation per ETAG 001, Annex C, design method B must be performed. For details, see ETA-04/0058. 4) Not included in the approval ETA-04/0058. Complete your designs more easily by downloading our LIEBIG anchor software from our home-page: www.simpson-liebig.com

df

h ef

t fix

39

VESF CHEMICAL ANCHOR SYSTEM


High-performance vinylester (styrene-free) injection mortar for xing into non-cracked concrete.

Function: After drilling and cleaning the hole, the adhesive mortar is injected with an applicator gun. A static mixing nozzle assures that the chemical components are properly mixed. Immediately afterwards a threaded stud is inserted into the resin with a twisting action to ensure even distribution of resin over the stud length and to displace any entrapped air. After the adhesive mortar has cured, the anchor can be fully loaded. The completed chemical reaction creates a durable expansion pressure free bond between the anchor stud, the reacted resin, and the concrete. Benefits: Fixing produces no expansion pressure Reduced edge distances and spacings Installation into damp holes permitted Completely seals drilled hole Virtually odour free

40

C-SL-2009E 2009 SIMPSON STRONG-TIE

Adhesive Systems

VESF
CONSTRUCTION:

Threaded Stud LMAS


with hex nut and washer

VESF 300 ml, 345 ml and 410 ml cartridges

Applicator Guns
(see pg. 58)

MATERIAL:
VESF: Vinylester resin (styrene-free), hardener and inorganic agents LMAS: Grade 5.8 carbon steel, zinc plated and blue passivated LMAS: A4-70 stainless steel

BASE MATERIAL:
Non-cracked concrete C20/25 to C50/60 Also suitable for other base materials (on-site testing recommended)

APPROVAL:
ETA-09/0153: M8 M24, carbon steel, zinc plated ETA pending: M8 M24, A4 stainless steel

LOAD RANGE:
Tension: Shear: Nperm = 5.2 - 46.9 [kN] Vperm = 5.1 - 56.8 [kN]

STORAGE OF VESF CARTRIDGES:


Dry, out of direct sunlight at a temperature between +5C and +25C

TEMPERATURE RANGE:
Maximum long-term service temperature = +24C; Maximum short-term service temperature = +40C

PRODUCT RANGE:
VESF cartridges: 300ml, 345 ml and 410ml LMAS threaded studs: M8 M24, carbon steel, zinc plated and blue passivated / A4 stainless steel

APPLICATIONS:
Steel and metal construction Racking systems Railings Awnings Machines

BENEFITS:
Causes no expansion pressure Reduced edge distances and spacings High capacity in non-cracked concrete Installation into damp holes permitted No special setting tool required for threaded stud Completely seals drilled hole

PRODUCT DESCRIPTION:
The VESF Chemical Anchor system consists of a threaded stud and a 2-component chemical-lled cartridge system. The mortar is injected into the drilled hole with an applicator gun. A static mixing nozzle is used to ensure that the chemical components are properly mixed. A chemical reaction ensues and the mortar cures over a time period depending on the base material temperature. Immediately after injection, a threaded stud is inserted into the hole. After the adhesive mortar has cured, the anchor can be fully loaded. The completed chemical reaction creates a durable expansion pressure free bond between the anchor stud, the reacted resin, and the concrete. The bond strength between the cured chemical and the drilled hole is dependent on the thorough cleaning of the drilled hole. Follow the installation instructions carefully.

C-SL-2009E 2009 SIMPSON STRONG-TIE

SHELF LIFE:
12 months after manufacture when stored according to the above recommendations. The manufacturing date is printed on the cartridge.

INSTALLATION:
Pre-fix installation shown

90

Drill hole

Clean out hole using a wire Dispense mortar to side brush and blow out pump until properly mixed (blow out 5x, brush 4x and (uniform colour) blow out 5x)

Inject mortar into the hole

Insert threaded stud with a twisting action and observe the specied cure time

Attach xture and apply the recommended fastening torque with a calibrated torque wrench

41

Adhesive Systems

VESF
Carbon steel, zinc plated
LMAS
Threaded stud with hex nut and washer Material: Grade 5.8, carbon steel, zinc plated and blue passivated Approval: ETA-09/0153 Thread Size x Depth of Drilled Hole d o x h1 LMAS M8 x 110 LMAS M10 x 130 LMAS M10 x 165 LMAS M12 x 150 LMAS M12 x 185 LMAS M16 x 170 LMAS M16 x 200 LMAS M20 x 245 LMAS M24 x 310 LMAS0810080020 LMAS1012090025 LMAS1012090060 LMAS1214100035 LMAS1214100070 LMAS1618130020 LMAS1618130050 LMAS2025170050 LMAS2428210070 [mm] M8 M10 M10 M12 M12 M16 M16 M20 M24 [mm] 10 x 80 12 x 90 12 x 90 14 x 100 14 x 100 18 x 130 18 x 130 24 x 170 28 x 210 Max. Fixture Thickness tx [mm] 20 25 60 35 70 20 50 50 70 Fixture Hole df [mm] 9 12 12 14 14 18 18 22 26 Eff. Embedment Depth hef [mm] 80 90 90 100 100 130 130 170 210 Total Length L [mm] 110 130 165 150 185 170 200 245 310 [kg/100 pcs] 4.0 9.0 10.6 13.6 16.8 26.8 31.5 55.8 101.8 [pcs] 20 10 10 10 10 10 10 6 6 Box Quantity

Type

Order Code

Weight

Custom lengths and grades available on request.

A4 stainless steel
LMAS A4
Threaded stud with hex nut and washer Material: A4-70 stainless steel Approval: ETA (pending) Thread Size x Depth of Drilled Hole d o x h1 LMAS M8 x 110 A4 LMAS M10 x 130 A4 LMAS M10 x 165 A4 LMAS M12 x 150 A4 LMAS M12 x 185 A4 LMAS M16 x 170 A4 LMAS M16 x 200 A4 LMAS M20 x 245 A4 LMAS M24 x 310 A4 LMAS0810080020A4 LMAS1012090025A4 LMAS1012090060A4 LMAS1214100035A4 LMAS1214100070A4 LMAS1618130020A4 LMAS1618130050A4 LMAS2025170050A4 LMAS2428210070A4 [mm] M8 M10 M10 M12 M12 M16 M16 M20 M24 [mm] 10 x 80 12 x 90 12 x 90 14 x 100 14 x 100 18 x 130 18 x 130 24 x 170 28 x 210 Max. Fixture Thickness tx [mm] 20 25 60 35 70 20 50 50 70 Fixture Hole df [mm] 9 12 12 14 14 18 18 22 26 Eff. Embedment Depth hef [mm] 80 90 90 100 100 130 130 170 210 Total Length L [mm] 110 130 165 150 185 170 200 245 310 [kg/100 pcs] 4.0 9.0 10.6 13.6 16.8 26.8 31.5 55.8 101.8 [pcs] 20 10 10 10 10 10 10 6 6 Box Quantity

Type

Order Code

Weight

Custom lengths and grades available on request.

VESF Injection mortar-cartridges

Contains a styrene-free vinylester resin, hardener and inorganic agents g g

300 ml Cartridge (silicone tool) Type VESF 300 VESF 345 VESF 410
*Each cartridge includes 1 mixing nozzle.

345 ml Side-by-side cartridge Order Code VESF300 VESF345 VESF410 Content [ml] 300 345 410 Weight [kg/12 pcs] 7.2 8.4 10.8

410 ml Coaxial cartridge Box Quantity* [pcs] 15 12 12

Mixing Nozzle

Type Mixing Nozzle 42

Order Code MD

Weight [kg/100 pcs] 1

C-SL-2009E 2009 SIMPSON STRONG-TIE

Adhesive Systems

VESF

TECHNICAL DATA

Carbon steel, zinc plated / A4 stainless steel


Permissible loads for single anchors with no inuencing edge distances or spacings. Loads are calculated using partial safety factors from ETAG 001 and the characteristic anchor and installation data from this catalogue. Design calculations shall follow the requirements of ETA-approvals ETA-09/0153 (A4 pending). Material: Carbon steel, Grade 5.8, zinc plated and blue passivated; A4-70 stainless steel / VESF (Vinylester resin, styrene-free)
Thread size Effective embedment depth (hef) Type LMAS Permissible tension loads1) Non-cracked concrete3) M8 80 M8 x ... Steel 5.3 5.7 6.1 6.2 A4 5.3 5.3 5.3 5.3 M10 90 M10 x ... Steel 8.3 8.9 9.5 9.8 A4 8.3 8.3 8.3 8.3 M12 100 M12 x ... Steel 13.2 14.3 15.2 15.6 A4 13.2 13.2 13.2 13.2 M16 130 M16 x ... Steel 24.8 26.8 28.5 29.3 A4 24.8 24.8 24.8 24.8 M20 170 M20 x ... Steel 26.9 29.1 31.0 31.8 A4 26.9 26.9 26.9 26.9 M24 210 M24 x ... Steel 39.7 42.9 45.6 46.8 A4 39.7 39.7 39.7 39.7

[mm]

Nperm

C20/25 C30/37 C40/50 C50/60

[kN] [kN] [kN] [kN]

Permissible shear loads1) 2) Non-cracked concrete3)

Vperm

C20/25 C30/37 C40/50 C50/60

[kN] [kN] [kN] [kN]

5.1 5.1 5.1 5.1

5.6 5.6 5.6 5.6

8.6 8.6 8.6 8.6

9.2 9.2 9.2 9.2

12.6 12.6 12.6 12.6

13.3 13.3 13.3 13.3

23.4 23.4 23.4 23.4

25.2 25.2 25.2 25.2

36.6 36.6 36.6 36.6

39.4 39.4 39.4 39.4

52.6 52.6 52.6 52.6

56.8 56.8 56.8 56.8

Permissible bending moments1) Mperm

[Nm]

10.9

11.9

22.3

23.8

38.9

42.1

98.9

106.7

192.6

207.9

333.7

359.9

Spacings, edge distances and member thicknesses [mm] Effective embedment depth hef scr,N [mm] Characteristic spacing4) [mm] Minimum spacing smin [mm] Characteristic edge distance4) ccr,N [mm] Minimum edge distance cmin [mm] Minimum member thickness hmin Installation data Drill hole diameter Drill hole depth Clearance hole in the xture Width across ats Installation torque Installed anchor
L

80 160 40 80 40 160

90 180 45 90 45 180

100 200 50 100 50 200

130 260 75 130 75 260

170 340 85 170 85 340

210 420 105 210 105 420

d0 h1 df sw Tinst

[mm] [mm] [mm] [mm] [Nm]

10 80 9 13 15

12 90 12 17 30

14 100 14 19 50

18 130 18 24 100

24 170 22 30 160

28 210 26 36 240

sw

T inst

Curing schedule Temperature [C] Gel time [min] Curing time [min] -5 to 0 25 150 1 to 5 6 to 10 11 to 15 16 to 20 21 to 25 12 9 6 5 3 80 50 45 35 30

d0

h0 = h ef hmin

tfix

C-SL-2009E 2009 SIMPSON STRONG-TIE

1) The permissible loads have been calculated using the partial safety factors for resistances stated in the ETA-approval and a partial safety factor for actions of F = 1.4. The permissible loads are valid for unreinforced concrete and reinforced concrete with a rebar spacing s 15 cm and reinforced concrete with a rebar spacing s 10 cm if the rebar is 10 mm or smaller. 2) The permissible shear loads are based on a single anchor without inuencing concrete edges. For shear loads applied close to an edge (c 10 hef or 60 d) concrete edge failure must be checked per ETAG 001, Annex C, design method A. 3) Concrete is considered non-cracked when the tensile stress within the concrete is L + R 0. In the absence of detailed verication R = 3 N/mm can be assumed (L equals the tensile stress within the concrete as a result of external loads, forces on anchors included). 4) If spacings or edge distances become smaller than the characteristic values (i.e. s scr,N and/or c ccr,N) a calculation per ETAG 001, Annex C, design method A must be performed. For details, see ETA 09/0153 (A4 pending). Complete your designs more easily by downloading our LIEBIG anchor software from our home-page: www.simpson-liebig.com

df

43

INJECTION 2000 CHEMICAL ANCHOR SYSTEM


Polyester injection mortar for xings in masonry and non-cracked concrete.

Function: After drilling and cleaning the hole, the adhesive mortar is injected with an applicator gun. A static mixing nozzle assures that the chemical components are properly mixed. Immediately afterwards a threaded stud is inserted into the resin with a twisting action to ensure even distribution of resin over the stud length and to displace any entrapped air. For fixing into hollow masonry, a plastic or metal sieve is used in order to prevent excessive flow of the adhesive into the masonry voids. After the adhesive mortar has cured, the anchor can be fully loaded. The completed chemical reaction creates a durable expansion pressure free bond and/or mechanical interlock between the anchor stud, the reacted resin, and the base material. Benefits: Fixing produces no expansion pressure Reduced edge distances and spacings Completely seals drilled hole Fast-curing

44

C-SL-2009E 2009 SIMPSON STRONG-TIE

Adhesive Systems

INJECTION 2000
CONSTRUCTION:

Threaded Stud LMAS


with hex nut and washer

INJECTION 2000
410 ml cartridge

Applicator Gun (see pg. 58)

MATERIAL:
Injection 2000: Polyester resin, hardener and mineral aggregates LMAS: Grade 5.8 carbon steel, zinc plated and blue passivated LMAS: A4-70 stainless steel

BASE MATERIAL:
Non-cracked concrete C20/25 to C50/60 Solid and hollow masonry Also suitable for other base materials (on-site testing recommended)

LOAD RANGE:
Tension: Shear: Nperm = 4.9 - 27.4 [kN] Vperm = 5.1 - 56.8 [kN]

STORAGE OF INJECTION 2000 CARTRIDGES:


Dry, out of direct sunlight, at a temperature between +5 C and +25 C

TEMPERATURE RANGE:
Maximum long-term service temperature = +40 C; Maximum short-term service temperature = +60 C

PRODUCT RANGE:
INJECTION 2000 cartridge: 410 ml LMAS threaded studs: M8 to M24, carbon steel, zinc plated and blue passivated / A4 stainless steel

APPLICATIONS:
Steel and metal construction Racking systems Machines Railings Awnings Sanitary xings Completely seals drilled hole No special setting tool required for threaded stud

BENEFITS:
Causes no expansion pressure Reduced edge distances and spacings

PRODUCT DESCRIPTION:
The INJECTION 2000 Chemical Anchor system consists of a threaded stud and a 2-component chemical-lled cartridge system. The mortar is injected into the drilled hole with an applicator gun. In the case of hollow masonry, a plastic or metal sieve is used in order to prevent excessive ow of the adhesive into the masonry voids. A static mixing nozzle is used to ensure that the chemical components are properly mixed. A chemical reaction ensues and the mortar cures over a time period depending on the base material temperature. Immediately after injection, a threaded stud is inserted into the hole (or sieve). After the adhesive mortar has cured, the anchor can be fully loaded. The completed chemical reaction creates a durable expansion pressure free bond and/or mechanical interlock between the anchor stud, the reacted resin, and the base material. The bond strength between the cured chemical and the drilled hole is dependent on the thorough cleaning of the drilled hole. Follow the installation instructions carefully.

SHELF LIFE:
C-SL-2009E 2009 SIMPSON STRONG-TIE

12 months after manufacture when stored according to the above recommendations. The manufacturing date is printed on the cartridge.

INSTALLATION:
Pre-fix installation shown

90

Drill hole

Clean out hole using a wire Dispense mortar to side brush and blow out pump until properly mixed (blow out 5x, brush 4x and (uniform colour) blow out 5x)

Inject mortar into the hole

Insert threaded stud with a twisting action and observe the specied cure time

Attach xture and apply the recommended fastening torque with a calibrated torque wrench

45

Adhesive Systems

INJECTION 2000
Carbon steel, zinc plated
LMAS
Threaded stud with hex nut and washer Material: Grade 5.8, carbon steel, zinc plated and blue passivated

Type

Order Code

Thread Size

x Depth of Drilled Hole d o x h1 [mm] 10 x 80 12 x 90 12 x 90 14 x 100 14 x 100 18 x 130 18 x 130 24 x 170 28 x 210

Max. Fixture Thickness tx [mm] 20 25 60 35 70 20 50 50 70

Fixture Hole df [mm] 9 12 12 14 14 18 18 22 26

Eff. Embedment Depth hef [mm] 80 90 90 100 100 130 130 170 210

Total Length L [mm] 110 130 165 150 185 170 200 245 310

Weight

Box Quantity

LMAS M8 x 110 LMAS M10 x 130 LMAS M10 x 165 LMAS M12 x 150 LMAS M12 x 185 LMAS M16 x 170 LMAS M16 x 200 LMAS M20 x 245 LMAS M24 x 310

LMAS0810080020 LMAS1012090025 LMAS1012090060 LMAS1214100035 LMAS1214100070 LMAS1618130020 LMAS1618130050 LMAS2025170050 LMAS2428210070

[mm] M8 M10 M10 M12 M12 M16 M16 M20 M24

[kg/100 pcs] 4.0 9.0 10.6 13.6 16.8 26.8 31.5 55.8 101.8

[pcs] 20 10 10 10 10 10 10 6 6

Custom lengths and grades available on request.

A4 stainless steel
LMAS A4
Threaded stud with hex nut and washer Material: A4-70 stainless steel

Type

Order Code

Thread Size

x Depth of Drilled Hole d o x h1 [mm] 10 x 80 12 x 90 12 x 90 14 x 100 14 x 100 18 x 130 18 x 130 24 x 170 28 x 210

Max. Fixture Thickness tx [mm] 20 25 60 35 70 20 50 50 70

Fixture Hole df [mm] 9 12 12 14 14 18 18 22 26

Eff. Embedment Depth hef [mm] 80 90 90 100 100 130 130 170 210

Total Length L [mm] 110 130 165 150 185 170 200 245 310

Weight

Box Quantity

LMAS M8 x 110 A4 LMAS M10 x 130 A4 LMAS M10 x 165 A4 LMAS M12 x 150 A4 LMAS M12 x 185 A4 LMAS M16 x 170 A4 LMAS M16 x 200 A4 LMAS M20 x 245 A4 LMAS M24 x 310 A4

LMAS0810080020A4 LMAS1012090025A4 LMAS1012090060A4 LMAS1214100035A4 LMAS1214100070A4 LMAS1618130020A4 LMAS1618130050A4 LMAS2025170050A4 LMAS2428210070A4

[mm] M8 M10 M10 M12 M12 M16 M16 M20 M24

[kg/100 pcs] 4.0 9.0 10.6 13.6 16.8 26.8 31.5 55.8 101.8

[pcs] 20 10 10 10 10 10 10 6 6

Custom lengths and grades available on request.

Injection 2000-Cartridge

Contains a polyester resin, hardener and mineral aggregates

410 ml Cartridge Type Injection 2000


* Each cartridge includes 1 mixing nozzle.

Order Code INJECTION2000

Content [ml] 410

Weight [kg/12 pcs] 10.8

Box Quantity* [pcs] 12

Mixing Nozzle

Type Mixing Nozzle 46

Order Code MD

Weight [kg/100 pcs] 1

C-SL-2009E 2009 SIMPSON STRONG-TIE

Adhesive Systems

INJECTION 2000 TECHNICAL DATA Carbon steel, zinc plated / A4 stainless steel
Recommended loads for single anchors with no inuencing edge distances or spacings. Material: Carbon steel, Grade 5.8, zinc plated and blue passivated; A4-70 stainless steel / Injection 2000 (polyester resin)
Thread size Effective embedment depth (hef) Type LMAS Recommended tension loads1) M8 80 M8 x ... Steel [kN] 4.9 A4 4.9 M10 90 M10 x ... Steel 7.5 A4 7.5 M12 100 M12 x ... Steel 10.6 A4 10.6 M16 130 M16 x ... Steel 12.3 A4 12.3 M20 170 M20 x ... Steel 19.9 A4 19.9 M24 210 M24 x ... Steel 27.4 A4 27.4

[mm]

Nperm

Non-cracked concrete2) C20/25 - C50/60

Recommended shear loads1) Non-cracked concrete2) Vperm C20/25 - C50/60 Recommended bending moments Mperm

[kN]

5.1

5.6

8.6

9.2

12.6

13.3

23.4

25.2

36.6

39.4

52.6

56.8

[Nm]

10.9

11.9

22.3

23.8

38.9

42.1

98.9

106.7

192.6

207.9

333.7

359.9

Spacings, edge distances and member thicknesses [mm] Effective embedment depth hef Characteristic spacing s3) [mm] Minimum spacing smin [mm] Characteristic edge distance for tension load Minimum edge distance for tension load Characteristic edge distance for shear load Minimum edge distance for shear load Minimum member thickness Installation data Drill hole diameter Drill hole depth Clearance hole in the xture Width across ats hex nut Installation torque for concrete Installation torque for brick Installed anchor
L

80 100 50 80 50 100 60 160

90 130 70 90 60 130 75 180

100 150 90 100 80 150 90 200

130 170 100 130 90 170 100 260

170 210 130 150 100 190 130 340

210 240 150 190 125 240 150 420

cN3) cmin,N cV3) cmin,V hmin

[mm] [mm] [mm] [mm] [mm]

d0 h1 df sw Tinst Tinst

[mm] [mm] [mm] [mm] [Nm] [Nm]

10 80 9 13 10 3

12 90 12 17 20 13

14 100 14 19 35 24

18 130 18 24 75 43

24 170 22 30 120 -

28 210 26 36 200 -

Typical performance in masonry


sw

T inst

Type LMAS M8 LMAS M10 LMAS M12 LMAS M16

h0 = h ef hmin
C-SL-2009E 2009 SIMPSON STRONG-TIE

tfix

Recommended load in all directions Brickwork Blockwork (20.5 N/mm2) (7 N/mm2) [kN] [kN] 1.7 0.8 3.4 1.7 4.8 2.7 5.6 3.6

d0

df

Curing schedule* Temperature [C] Gel time [min] Curing time [min] 0 50 90 5 12 50 15 6 35 25 3 30 35 2 25

* Figures based on M12 xings. Full cure is achieved after 24 hours!


1) Permissible loads in non-cracked concrete C20/25 - C50/60. 2) Concrete is considered non-cracked when the tensile stress within the concrete is L + R 0. In the absence of detailed verication R = 3 N/mm can be assumed (L equals the tensile stress within the concrete as a result of external loads, forces on anchors included). 3) If spacings or edge distances are smaller than the characteristic values, the permissible loads shall be reduced based on the Kappa method.

47

LSK AND LVK CHEMICAL ANCHOR SYSTEMS


For expansion pressure free xing in masonry.

Function: The system consists of a threaded stud, sieve, and injection mortar. The connection between the xing and the base material is created by bond with the base material (for solid masonry) or a combination of bond and mechanical interlock with cavities in the masonry (for hollow masonry). Benefits: Fixing produces no expansion pressure Reduced permissible edge distances and spacings Mixing nozzle ensures proper mixing of A and B components Reliable mechanical interlock in hollow masonry Completely seals drilled hole

I j ti Mortar Injection M t LSK 300 PSF


Internal bag cartridge system

I j i Mortar LVK 300 PSH and PSF Injection M d


Coaxial cartridge

Injection Injection Mortar LVK 345 PSH and PSF j


Side-by-side cartridge

Injection Mortar LVK 380 PSH and PSF


48

Coaxial cartridge

C-SL-2009E 2009 SIMPSON STRONG-TIE

Adhesive Systems

LSK AND LVK


CONSTRUCTION:

Threaded Stud LMAS

Injection Mortar LVK Injection Mortar LSK for Silicone Tools Applicator Guns (see pg. 58)
Z-21.3-1773
Institut fr Massivbau Technische Universitt Darmstadt

MATERIAL: LMAS: Grade 5.8 carbon steel, zinc plated and blue passivated LVK + LSK cartridges: Filled with polyester resin, mineral aggregates and hardener BASE MATERIAL: DIN 1053 Masonry Natural stone APPROVAL: Deutsches Institut fr Bautechnik (DIBt) Z-21.3-1773 LOAD RANGE: Fperm = 0.3 - 1.7 [kN] in all directions TEMPERATURE RANGE: Concrete

Maximum long-term service temperature = +50C; Maximum short-term service temperature = +80 C RANGE SUPPLIED: LMAS threaded stud: M8 M12, carbon steel, zinc plated and blue passivated APPLICATIONS: Brackets Steel construction Cable trays Railings BENEFITS: Causes no expansion pressure Reliable mechanical interlock in hollow masonry Reduced edge distances and spacings Completely seals drilled hole PRODUCT DESCRIPTION: The LSK and LVK Injection Anchor Systems is an expansion pressure free xing system that consists of injection mortar, a sieve and threaded stud with a hex nut and washer. The system is approved for use in masonry meeting DIN 1053 and is also suitable for use in concrete and natural stone. The load carrying capacity of the system results from bond and mechanical interlock of the injection mortar with the base material. The bond strength between the cured chemical and the drilled hole is dependent on the thorough cleaning of the drilled hole. Follow the installation instructions carefully STORAGE OF LVK + LSK: Dry, dark, at a temperature between +5C and +25C SHELF LIFE: 12 months after manufacture when stored according to the above recommendations INSTALLATION:
C-SL-2009E 2009 SIMPSON STRONG-TIE

Pre-fix installation shown

2x 3x

Drill hole
Solid masonry

Thoroughly clean (brushing + blowing)


Hollow masonry with sieve

Inject mortar

Fixing into masonry

49

Adhesive Systems

LSK AND LVK


Injection Mortar LVK/LSK
LVK/LSK - Cartridges: Filled up with polyester resin, hardener and mineral aggregates

300 ml Cartridge Type LSK 300 PSF styrene free with internal bag LVK 300 PSF styrene free LVK 300 PSH with styrene LVK 345 PSF styrene free LVK 345 PSH with styrene LVK 380 PSF styrene free LVK 380 PSH with styrene
* Each cartridge includes 1 mixing nozzle.

345 ml Side-by-side cartridge Order Code LSK300PSF LVK300PSF LVK300PSH LVK345PSF LVK345PSH LVK380PSF LVK380PSH Content [ml] 300 300 300 345 345 380 380 Weight [kg/12 pcs] 7.00 7.00 7.00 8.50 8.50 10.0 10.0

380 ml C i l cartridge l Coaxial t id Box Quantity [pcs] 12 12 12 12 12 12 12

Mixing Nozzle

Type Mixing Nozzle

Order Code MD

Weight [kg/100 pcs] 1

Threaded Stud LMAS


Threaded stud with hex nut and washer Material: Grade 5.8 steel, zinc plated and blue passivated Approval: Z-21.3-1773 Type Order Code Thread Size [mm] M8 M10 M12 Max. Fixture Thickness tx [mm] 10 10 10 Eff. Embedment Depth hef [mm] 80 90 80 Total Length L [mm] 100 110 110 Weight [kg/100 pcs] 3.6 7.0 10.0 Box Quantity [pcs] 10 10 10

LMAS M8x100 LMAS M10x110 LMAS M12x110*


*Not included in approval.

LMAS08080010 LMAS10090010 LMAS12090015

Custom lengths and stainless steel available on request.

Plastic Sieve SH
Nylon sieve

Type

Order Code

Compatible LMAS [mm] LMAS M8x100 LMAS M8x100 LMAS M10x110 LMAS M12x110

Sieve

Sieve Length [mm] 85 100 85

SH 15/85 SH 15/100 SH 20/85*


*Not included in approval.

SH15085 SH15100 SH20085

[mm] 15 15 20

[kg/100 pcs] 0.4 0.6 0.8

[pcs] 12 12 12

16 x 105 20 x 90

Metal Sieve SHM


Steel sieve (cut to length required)

Type

Order Code

Compatible LMAS [mm] LMAS M10 + M12

Sieve

Sieve Length [mm] 1000

SHM 16/1000* 50
*Not included in approval.

SHM161000

[mm] 16

x Depth of Drilled Hole d0 [mm] 16

Weight

Box Quantity [pc] 1

[kg/100 pcs] 7.6

C-SL-2009E 2009 SIMPSON STRONG-TIE

x Depth of Drilled Hole d0 x h1 [mm] 16 x 90

Weight

Box Quantity

Adhesive Systems

LSK AND LVK


Internally Threaded Sleeve IGH
Steel internally threaded sleeve

Type

Order Code

Compatible LMAS [mm] LMAS M8 LMAS M10 LMAS M12

Sieve [mm] 12 14 16

Sieve Length [mm] 80 80 80

IGH M8x80* IGH M10x80* IGH M12x80*


*Not included in approval.

IGH08080 IGH10080 IGH12080

x Depth of Drilled Hole d0 x h1 [mm] 14 x 90 16 x 90 18 x 90

Weight [kg/100 pcs] 3.5 4.8 5.6

Box Quantity [pcs] 12 12 12

Curing Schedule
Temperature Working time Cure time C min min +5 20 120 +20 6 45 +30 4 25 +40 2 15

Base material temperature shall not fall below +5 C during the cure time.

Load Capacity in Masonry


Permissible loads Fperm for single anchors for tension, shear and oblique loads in any direction Sieve Type Setting Depth [mm] 85 100 85 Drilled Hole Size do [mm] 16 16 20 h1 [mm] 90 105 90 [mm] M8 M8 M10 M121) Threaded Stud Eff. Embedment Depth hef [mm] 80 80 90 80 MZ 12 [kN] 1.7 1.7 1.7 KS 12 [kN] 1.7 1.7 1.7 Hlz 4 [kN] 0.3 (0.6) 0.3 (0.6) 0.3 (0.6) Permissible Loads2) Hlz 6 [kN] 0.4 (0.8) 0.4 (0.8) 0.4 (0.8) Hlz 12 [kN] 0.8 (1.0) 0.8 (1.0) 0.8 (1.0) KSL 4 [kN] 0.4 (0.6) 0.4 (0.6) 0.4 (0.6) KSL 6 [kN] 0.6 (0.8) 0.6 (0.8) 0.6 (0.8) KSL 12 [kN] 0.8 (1.4) 0.8 (1.4) 0.8 (1.4)

SH 15/85 SH 15/100 SH 20/85


1)

1) Not included in approval. 2) MZ = DIN 1053 solid masonry. KS = DIN 1053 solid limestone masonry. Hlz = DIN 1053 hollow masonry. KSL = DIN 1053 limestone hollow masonry. The number following the masonry type indicates the compressive strength in N/mm2. For anchoring in Hlz, the load capacity in parentheses may be used if the hole is drilled in rotation-only mode. For anchoring in KSL, the load capacity in parentheses may be used if the hole is drilled in rotation-only mode and the installer veries that the face shell is at least 30 mm thick.

Edge distances, Spacings and Member Dimensions


Sieve Threaded Stud Anchor Group3) Min. Spacing amin [mm] 50 Min. Spacing az [mm] 250 Single Anchor Edge Distance ar [mm] 200 ( 250)4) ar5) [mm] 50 ( 60)4) Min. Member Thicknes h [mm] 110 Fixture Hole df [mm] 9 12 14 2 Max. Install. Torque Tinst [Nm]

Type

Type

Spacing a [mm]

SH 15/85 SH 15/100 SH 20/85


C-SL-2009E 2009 SIMPSON STRONG-TIE
1)

LMAS M8 x 100 LMAS M8 x 100 LMAS M10 x 110 LMAS M12 x 110

100

3) The spacing a can be reduced for anchor groups if the permitted loads are reduced as specied in approval Z-21.3-1773. 4) Dimensions shown in parentheses are only valid for MZ and KS. 5) Special edge distance: Only valid for masonry that is in compression or restrained against overturning.

Member Dimensions
Permissible Loads for Anchor Groups with Reduced Spacings: amin ared < a Two anchor group: Four anchor group: Fred = a Fperm a = (1 + ared / a) 1.0 Fred = a1 a2 Fperm a1,2 = (1 + ared1,2 / a) 1.0

Fperm = Permissible load per anchor; Fred = Reduced load per anchor;
a = Spacing; ared = Reduced spacing

51

CHEMICAL ANCHOR PLUS


Polyester anchoring system for secure xing into non-cracked concrete.

Function: After drilling and cleaning the hole, the capsule is inserted into the hole and the anchor stud is driven with a rotating/hammering action. This breaks the capsule and mixes the contents. The resulting chemical reaction creates a durable expansion pressure free bond between the anchor stud, the reacted resin, and the concrete. Benefits: Expansion pressure free Reduced permissible edge distances and spacings Completely seals drilled hole

52

C-SL-2009E 2009 SIMPSON STRONG-TIE

Adhesive Systems

CHEMICAL ANCHOR PLUS


CONSTRUCTION: KLS Threaded stud KLP Capsule Setting tool
LIEBIG
Z-21.3-1772

MATERIAL: KLS: Carbon steel, zinc plated and blue passivated KLS A4: A4-70 stainless steel KLP: Glass capsule with polyester resin, hardener and mineral aggregates BASE MATERIAL: Non-cracked concrete C20/25 to C50/60 (B25 to B55) APPROVAL: Deutsches Institut fr Bautechnik (DIBt) Z-21-1772 LOAD RANGE: Tension: Shear: Nperm = 4.0 - 60.0 [kN] Vperm = 4.0 - 60.0 [kN]

BERWACHT

TEMPERATURE RANGE: Maximum long-term service temperature = +50C; Maximum short-term service temperature = +80 C RANGE SUPPLIED: KLS: M8 M30, carbon steel, zinc plated and blue passivated / A4 stainless steel APPLICATIONS: Brackets Base plates Railings BENEFITS: Causes no expansion pressure Reduced edge distances and spacings High capacity in non-cracked concrete Steel construction Storage racks Machines Stud with hex head for easy installation with setting tool Completely seals drilled hole

PRODUCT DESCRIPTION: The Chemical Anchor Plus adhesive xing system consists of a threaded stud and chemical-lled glass capsule. During installation, the capsule is crushed and the rotating and hammering action mixes the contents. After the recommended cure time, the xture can be installed and the xing can be loaded. Capsule have shelf life of 2 years when stored correctly. Dont use if capsule is damaged or if the contents do not ow in a honey-like fashion of room temperature. The bond strength between the cured chemical and the drilled hole is dependent on the thorough cleaning of the drilled hole. Follow the installation instructions carefully. STORAGE OF KLP: Dry, dark, at a temperature between +5C and +25C. Avoid direct sunlight. SHELF LIFE: 2 years after manufacturing date when stored according to the above recommendations.
C-SL-2009D 2008 SIMPSON STRONG-TIE

INSTALLATION: Pre-fix installation shown

90

Drill hole and thoroughly clean (brushing and blowing)

Insert KLP capsule into drilled hole

Spin in KLS stud to the embedment depth marking using a rotary hammer drill

After the specified cure time, install the fixture and apply the recommended fastening torque with a calibrated torque-wrench 53

Photo: Ldige

Adhesive Systems

CHEMICAL ANCHOR PLUS


Carbon steel, zinc plated / A4 stainless steel
KLS, CARBON STEEL, ZINC PLATED
Threaded stud with hex head, hex nut and washer Material: Grade 5.8 steel, zinc plated and blue passivated Approval: Z-21.3-1772 x Depth of Drilled Hole do x h1 [mm] 10 x 80 12 x 90 12 x 90 12 x 90 14 x 110 14 x 110 14 x 110 14 x 110 18 x 125 18 x 125 18 x 125 18 x 125 25 x 170 25 x 170 28 x 210 35 x 280 Max. Fixture Thickness tx [mm] 16 22 57 82 30 90 120 170 13 38 98 148 20 60 55 55 Eff. Fixture Embedment Hole Depth df hef [mm] [mm] 9 80 12 90 12 90 12 90 14 110 14 110 14 110 14 110 18 125 18 125 18 125 18 125 22 170 22 170 26 210 33 280 Total Length L [mm] 110 130 165 190 160 220 250 300 165 190 250 300 220 260 300 380

Type

Order Code

Thread Size [mm] M8 M10 M10 M10 M12 M12 M12 M12 M16 M16 M16 M16 M20 M20 M24 M30

Weight

Box Quantity* [pcs] 10 10 10 10 10 10 10 10 10 10 10 10 6 6 6 4

Compatible Capsule [Type] KLP 8 KLP 10 KLP 10 KLP 10 KLP 12 KLP 12 KLP 12 KLP 12 KLP 16 KLP 16 KLP 16 KLP 16 KLP 20 KLP 20 KLP 24 KLP 30

KLS 8/110 KLS 10/130 KLS 10/165 KLS 10/190 KLS 12/160 KLS 12/220 KLS 12/250 KLS 12/300 KLS 16/165 KLS 16/190 KLS 16/250 KLS 16/300 KLS 20/220 KLS 20/260 KLS 24/300 KLS 30/380

KLS0810080016 KLS1012090022 KLS1012090057 KLS1012090082 KLS1214110030 KLS1214110090 KLS1214110120 KLS1214110170 KLS1618125013 KLS1618125038 KLS1618125098 KLS1618125148 KLS2025170020 KLS2025170060 KLS2428210055 KLS3035280055

[kg/100 pcs] 4.0 9.0 10.6 11.7 14.5 18.6 20.7 24.1 26.0 29.0 36.3 42.3 50.1 58.0 98.5 196.0

*Each box of KLS contains one setting tool. Custom lengths available on request.

KLS, A4 STAINLESS STEEL

Threaded stud with hex head, hex nut and washer Material: A4-70 stainless steel Approval: Z-21.3-1772 x Depth of Drilled Hole do x h1 [mm] 10 x 80 12 x 90 12 x 90 12 x 90 14 x 110 14 x 110 14 x 110 14 x 110 18 x 125 18 x 125 18 x 125 18 x 125 25 x 170 25 x 170 28 x 210 35 x 280 Max. Fixture Thickness tx [mm] 16 22 57 82 30 90 120 170 13 38 98 148 20 60 55 55 Eff. Fixture Embedment Hole Depth df hef [mm] [mm] 9 80 12 90 12 90 12 90 14 110 14 110 14 110 14 110 18 125 18 125 18 125 18 125 22 170 22 170 26 210 33 280 Total Length L [mm] 110 130 165 190 160 220 250 300 165 190 250 300 220 260 300 380

Type

Order Code

Thread Size [mm] M8 M10 M10 M10 M12 M12 M12 M12 M16 M16 M16 M16 M20 M20 M24 M30

Weight

Box Quantity* [pcs] 10 10 10 10 10 10 10 10 10 10 10 10 6 6 6 4

Compatible Capsule [Type] KLP 8 KLP 10 KLP 10 KLP 10 KLP 12 KLP 12 KLP 12 KLP 12 KLP 16 KLP 16 KLP 16 KLP 16 KLP 20 KLP 20 KLP 24 KLP 30

*Each box of KLS contains one setting tool. Custom lengths available on request.

KLP CAPSULE

Glass capsule Approval: Z-21.3-1772 Diameter [mm] 9 11 13 17 22 24 33 Length L [mm] 80 80 95 95 170 210 265 Weight [kg/100 pcs] 2.0 2.0 2.5 4.0 11.0 13.0 36.5 Box Quantity [pcs] 10 10 10 10 6 6 2

Type KLP 8 KLP 10 KLP 12 KLP 16 KLP 20 KLP 24 KLP 30

Order Code KLP08 KLP10 KLP12 KLP16 KLP20 KLP24 KLP30

54

C-SL-2009E 2009 SIMPSON STRONG-TIE

KLS 8/110A4 KLS 10/130A4 KLS 10/165A4 KLS 10/190A4 KLS 12/160A4 KLS 12/220A4 KLS 12/250A4 KLS 12/300A4 KLS 16/165A4 KLS 16/190A4 KLS 16/250A4 KLS 16/300A4 KLS 20/220A4 KLS 20/260A4 KLS 24/300A4 KLS 30/380A4

KLS0810080016A4 KLS1012090022A4 KLS1012090057A4 KLS1012090082A4 KLS1214110030A4 KLS1214110090A4 KLS1214110120A4 KLS1214110170A4 KLS1618125013A4 KLS1618125038A4 KLS1618125098A4 KLS1618125148A4 KLS2025170020A4 KLS2025170060A4 KLS2428210055A4 KLS3035280055A4

[kg/100 pcs] 4.0 9.0 10.6 11.7 14.5 18.6 20.7 24.1 26.0 29.0 36.3 42.3 50.1 58.0 98.5 196.0

Adhesive Systems

CHEMICAL ANCHOR PLUS TECHNICAL DATA


Carbon steel, zinc plated / A4 stainless steel
Permissible loads for single anchors without inuence from edge and spacing distances. Calculations shall follow the requirements of approval Z-21.3-1772.
Material: Carbon steel, zinc plated and blue passivated; A4 stainless steel Thread size Effective embedment depth Type KLS... Permissible loads at any angle1) Fperm Non-cracked concrete2) C20/25 - C50/60 [kN] [mm] M8 80 8/... Steel 4.0 A4 4.0 M10 90 10/... Steel 7.0 A4 7.0 M12 110 12/... Steel 10.0 A4 10.0 M16 125 16/... Steel 15.0 A4 15.0 M20 170 20/... Steel 27.0 A4 27.0 M24 210 24/... Steel 37.0 A4 37.0 M30 280 30/... Steel 60.0 A4 60.0

Permissible bending moments Mperm [Nm] 10.7 12.1 21.4 24.1 37.4 42.7 94.9 107.0 186.0 209.0 321.0 360.8 642.0 723.2

Spacings, edge distances and member thicknesses Effective embedment depth Characteristic spacing3) Minimum spacing Characteristic edge distance3) Minimum edge distance Minimum member width Minimum member thickness Installation data Drill hole diameter Drill hole depth Clearance hole in the xture Width across ats hex nut Installation torque Installed anchor d0 h1 df sw Tinst [mm] [mm] [mm] [mm] [Nm]
L sw

hef a amin ar ar,min bmin hmin

[mm] [mm] [mm] [mm] [mm] [mm] [mm]

80 200 80 100 40 80 130

80 200 80 100 40 80 130

90 220 90 110 45 90 140

90 220 90 110 45 90 140

110 270 110 135 55 110 160

110 270 110 135 55 110 160

125 310 125 155 65 125 175

125 310 125 155 65 125 175

170 420 170 210 85 170 220

170 420 170 210 85 170 220

210 520 210 260 105 210 260

210 520 210 260 105 210 260

280 700 280 350 140 280 330

280 700 280 350 140 280 330

10 80 9 13 10

12 90 12 17 20

14 110 14 19 40

18 125 18 24 80

25 170 22 30 150

28 210 26 36 200

35 280 33 46 400

T inst

d0

Curing schedule Drill hole temperature [C] > 20 10 - 20 0 - 10 Curing time [min] 10 20 60

h0 = hef hmin

tfix

1) Permitted loads per anchor in non-cracked concrete of strength C20/25 to C50/60 (B25 to B55) for axial tension, shear, and oblique loads. 2) Concrete is considered non-cracked when the tensile stress within the concrete L + R 0. In the absence of a detailed analysis R = 3 N/mm2 can be assumed (L equals the tensile stress within the concrete resulting from external loads, including forces on the anchor). 3) If spacings or edge distances are smaller than the characteristic values, the permissible loads shall be reduced based on the Kappa method (see Z-21.3-1772, Annexes 4 + 5). Complete your designs more easily by downloading our LIEBIG anchor software from our home-page: www.simpson-liebig.com

C-SL-2009E 2009 SIMPSON STRONG-TIE

df

55

WECO
The dependable brass plug anchor with three-piece expansion mechanism.

Function: When the bolt is installed, it compresses the three internal expansion components and expands the anchor in a displacement controlled fashion. The expansion segments develop a frictional grip with the sidewalls of the hole. This gives the anchor its resistance to tension loads. Benefits: Corrosion resistant brass material Can be installed flush with the base material surface or deeply embedded No special setting tool is required Often used with spiral anchor in masonry cavity walls

Type

Order Code

Diameter x Length Dw x L [mm] 5.5 x 21 7 x 26.5 8 x 30 11 x 40 14 x 45

x Depth of Drilled Hole d0 x BT [mm] 5.5 x 30 7 x 35 8 x 40 11 x 50 14 x 58

Bolt Length Ls [mm] 15 + K2) 20 + K2) 20 + K2) 25 + K2) 25 + K2)

Bolt Head Standoff N [mm] 10 15 15 20 20

Min. Edge Distance smin [mm] 65 85 100 130 160

Recommended Load in C20/253) Concrete [kN] 0.5 1.0 1.2 2.0 2.5

Weight

Box Quantity

WECO M41) WECO M51) WECO M61) WECO M81) WECO M101)
1) Internal thread

MW04 MW05 MW06 MW08 MW10

[kg/100 pcs] 0.3 0.5 0.8 2.2 2.4

[pcs] 100 100 100 100 50

2) K = Fixture thickness

3) Factor of safety = 5

K N Ls
C-SL-2009E 2009 SIMPSON STRONG-TIE

BT
Setting standoff: Insert plug and bolt assembly until bolt head standoff N is achieved.

INSTALLATION:

1. Drill and clean hole.

2. Insert plug and bolt assembly until standoff is achieved.

3. Anchor expands when bolt is tightened.

56

ACCESSORIES
F1

DIN 582 Ring Nut, C15E steel, zinc plated and blue passivated
Inner Type RM8-C15E RM10-C15E RM12-C15E RM16-C15E RM20-C15E Order Code RMC0008 RMC0010 RMC0012 RMC0016 RMC0020 [mm] 20 25 30 35 40 [mm] 36 45 54 63 72 [kg/100 pcs] 5 9 16 24 36 [pcs] 50 25 10 10 5 Outer Weight Box Quantity Permissible Tension Load F1 [kN] 1.4 2.3 3.4 7.0 12.0

F1

High Strength Ring Nut, 42CrMo4 steel, zinc plated and blue passivated
Inner Type RMH8-HF RMH10-HF RMH12-HF RMH16-HF Order Code RMH0008 RMH0010 RMH0012 RMH0016 [mm] 20 25 30 35 [mm] 36 40 54 64 [kg/100 pcs] 5 9 16 24 [pcs] 10 10 10 10 Outer Weight Box Quantity Permissible Tension Load F1 [kN] 7.6 9.4 15.0 38.0

Hexagonal Screw Socket, steel, zinc plated and blue passivated


Type Order Code Internal Thread Length L* [mm] 20 25 30 36 40 50 Width Across Flats sw [mm] 9 11 13 17 22 24 Weight Box Quantity

GM6/20 GM8/25 GM10/30 GM12/35 GM16/40 GM20/50

GM0620 GM0825 GM1030 GM1235 GM1640 GM2050

[mm] M6 M8 M10 M12 M16 M20

[kg/100 pcs] 2.5 3.3 6.0 12.0 16.0 20.0

[pcs] 200 200 100 50 25 25

*Maximum screw installation depth = L/2

Specials/Custom Anchors
Safety Bolt with Hexagonal Screw Socket

Safety Bolt with Extended Stud


C-SL-2009E 2009 SIMPSON STRONG-TIE

Safety Bolt with Ring Nut

Specials also available with other products.

57

ACCESSORIES
Quick-Set Drive Unit
Use this setting tool with a standard drill to provide problem-free setting of M8-M20 threaded studs with the Chemical Anchor Plus (KLP) system (see page 44). The Quick-Drive setting tool also has a hexagonal recess that allow it to set threaded studs with hex heads. Type BE
Type Quick-Set Drive Unit M8 Quick-Set Drive Unit M10 Quick-Set Drive Unit M12 Quick-Set Drive Unit M16 Quick-Set Drive Unit M20 Order Code BE08 BE10 BE12 BE16 BE20 Size M8 M10 M12 M16 M20 Weight [kg/100 pcs] 11 14 14 20 34

Applicator Guns
Type LAC
For 300 ml silicone and coaxial cartridges Type Order Code Compatible Cartridge LVK 300 VESF 300 Weight [kg/pc] 1.0

Applicator Gun Type LAC

LAC300

Type LAS

For 345 ml side-by-side cartridges Type Order Code Compatible Cartridge VESF 345 LVK 345 Weight [kg/pc] 1.0

Applicator Gun Type LAS

LAS345

Type LAP

For 380 ml and 410 ml coaxial cartridges Type Order Code Compatible Cartridge VESF 410 Injection 2000 LVK 380 Weight [kg/pc]

Dust Pump
Type Dust Pump Order Code LAB Weight [kg/pc] 0.22

58

C-SL-2009E 2009 SIMPSON STRONG-TIE

Applicator Gun Type LAP

LAP380

1.2

FAX ENQUIRY FORM

Fax Number: U.K. (0)1827 255 616 Ireland (0) 66 976 1758
Pcs Order Code Price/100 pcs Discount

C-SL-2009E 2009 SIMPSON STRONG-TIE

Sender:

SIMPSON STRONG-TIE
Winchester Road Cardinal Point Tamworth, Staffordshire B78 3HG United Kingdom Tel: +44 1827 255 600 Fax: +44 1827 255 616 liebig-uk@strongtie.com Killarney Road Killorglin, Co. Kerry Ireland Tel: +353 66 976 15 22 Fax: +353 66 976 17 58 liebig-ie@strongtie.com

Date

Signature
59

SIMPSON STRONG-TIE Ireland Ltd.


www.simpson-liebig.com

Winchester Road Cardinal Point Tamworth, Staffordshire B78 3HG United Kingdom Tel: +44 1827 255 600 Fax: +44 1827 255 616 liebig-uk@strongtie.com Killarney Road Killorglin, Co. Kerry Ireland Tel: +353 66 976 15 22 Fax: +353 66 976 17 58 liebig-ie@strongtie.com
05/2009 3,0 gr-a/sum

Wormser Strae 23 64319 Pfungstadt Germany Tel: +49 (0)6157 / 9868-0 Fax: +49 (0)6157 / 9868-7700 liebig-de@strongtie.com

Member:

Você também pode gostar