Vendor has to supply: Equipment lifetime. Engineering documentation.

tion. Vendor is responsible for any other parts to be done by other manufacturers. Detailed scope of supply. Layout of package(s) within package allowable space.

Package turndown Sub-supplier list. All equipment special tools required for maintenance and overhaul. Complete client data sheets Design, engineer, fabricate, test and supply this package. Pre-commissioning, commissioning and start-up spare parts for pumps/engine controllers. Separate quotation for 2 years spare parts. P&ID's and documentation: Includes installation, operation and maintenance manual. Inspection & Testing. Instrumentation & Accessories:- The supplied instruments should be available for 10 years. - Fiber / Nylon explosion proof cable glands to be used. - All insulation materials shall be flame retardant, low halogen content. - 316 St.St cable tray. - St.St. fitting (Compression type). - 316 St.St. instrument air tubing. - Instrument air tubing header & branches. - SDV's shall have 2 solenoid valves and automatic reset, SDV's valves 12" and over shall have double acting actuator and fail false. - All field instrument cables shall have steel wires with flame retardant. - Solenoid valves shall be explosion proof. - All electronic field instrumentation shall be covered with polyester for protections from direct sun radiation. - Control valves shall be low emission valve stem. Steel Structure & Accessories: Baseplates : Rigid self-supporting type. Ladders : Painted steel or galvanized steel. Platforms : Covered by galvanized grating. Handrails : Painted steel or galvanized steel. Pipe supports : Painted steel or galvanized steel. - Walkways : Galvanized steel. - Grating : Galvanized steel. Piping & Accessories: - Gaskets - Piping - Valves - Fittings - Bolting. Electrical & Accessories: - Power distribution board(s) - Electrical cables. - Grounding : Asbestos free, spiral wound, metallic spiral wound. : Material & wall thickness by vendor.

Lighting material

: No. of grounding bosses is tow minimum. : 95 mm2 routed on the main cable support system. : Grounding cable to be high conductivity copper PVC insulation. : Normal lighting 150 watt, high pressure sodium or

metal halide. : Emergency lighting is fluorescent type 2x40 watt with built in Nickel Cadmium battery with back up time of 2 hrs. - Cable glands. - Fittingsetc. - Junction box(s) - Cable tray All electric motors External protective coating Hydraulic test Drivers

: Heavy duty hot dip galvanized steel. : To be explosion proof. : Will be sandblasted and coated with 3 coats. : 1.5 times the max. working pressure for 1hr. : 1- To be certified for the use in hazardous area : 2- To be (non - sparking) explosion proof.