Escolar Documentos
Profissional Documentos
Cultura Documentos
PLCs
MicroSmart Pentra CPU Part Numbers ..............7 MicroSmart CPU Part Numbers .........................8 Expansion Modules ..........................................10 Programming Software - WindLDR .................23 Specications & Dimensions ...........................24
Operator Interfaces
For more information on this product family, visit our website. Additional resources include:
Communication & Networking
New and updated product information Downloadable software demos & upgrades Part conguration tool & cross reference Online stock check & ordering IDEC eld sales & distributor search Online literature request
Downloadable manuals & CAD drawings Manufacturers suggested retail price list Product training schedule & locations Advertising & trade show schedules Press releases & FAQs
www.idec.com/plc
Table of Contents Automation & Sensing - Pg. 1 Safety - Pg. 315 Switching & Controls - Pg. 439 Index - Pg. 911
SmartRelay 56
NEW
Appearance
Operator Interfaces
Rated Voltage Max. Digital I/O Max. Analog I/O Program Capacity Max. Communication Ports Networking Modbus RTU/ASCII Modbus TCP AS-Interface LONWORKS 32-bit Data Floating Point Math High-Speed I/O Freq.
24V DC, 100-240V AC 512 56 62.4K bytes 7 Yes Yes Yes Yes Yes 100KHz
12-24V DC, 24V AC/DC, 100-240V AC/DC 50 10 2K bytes 1 Yes Yes 2KHz
Power Supplies
Automation Software
Approvals
FM
APPROVED
Sensors
www.idec.com
MicroSmart Series
PLCs
Micro-controllers play an increasingly central role in todays industrial applications. You have many controllers to choose from, but the one you turn to most often is the one that ts best, physically and practically. Youll nd IDEC PLCs in various applications from water treatment plants to HVAC to printing press operations and more. Theyre always dependable, easy to program and almost as smart as you are. IDEC brought some of the rst micro-PLCs to the market, and has been meeting your changing control automation needs for decades. Now with the MicroSmart Pentra, you get the fastest and most full featured programmable logic controller there is.
Operator Interfaces
International Approvals
All MicroSmart controllers have regulatory agency certications for the worldwide market including being cULus Listed for Class1 Division 2 Hazardous Locations, TUV approved, CE, and certied for marine use by ABS and Lloyds Registry.
Automation Software
USA: 800-262-IDEC
Canada: 888-317-IDEC
MicroSmart Series
MicroSmart Pentra Performance
PLCs
ADD(F)
Operator Interfaces
LOD MOV
0s
0.9s 2.4s
I0000
Built-in Modbus RTU/ASCII master & slave, and Modbus TCP (1:1) de-facto protocol
Modbus messaging protocol is a de-facto protocol in industrial networking. Communication with other devices on a Modbus network can be easily achieved with built-in Macros instructions.
Modbus
Sensors
Inverters
Temperature Controllers
HG Operator Interface
www.idec.com
MicroSmart Series
V out
1 PULSE
Automation Software
56 PID Loops
PID is the standard solution to many industrial process controls because of its accuracy and stability. With up to 56 PID loops and advanced auto-tuning features, your systems can be tuned to optimum values for the desired control response.
USA: 800-262-IDEC
Canada: 888-317-IDEC
MicroSmart Series
All-in-One CPU
PLCs
Operator Interfaces
All-in-one CPU
Optional RS485 adapter
FC5A-C24R2C
Automation Software
Slim CPU
Optional HMI module for monitoring Optional HMI base module or RS232C/RS485 Comm. Modules Built-in Potentiometer
Power Supplies
Sensors
Slim CPU
www.idec.com
MicroSmart Series
Output
Expandability
PLCs
Operator Interfaces
24V DC (Sink/Source)
Relay
FC5A-C24R2C
FC5A-C24R2
100-240V AC
Automation Software
Slim
Appearance Part Number FC5A-D16RK1 16 (8 in/8 out) FC5A-D16RS1 24V DC FC5A-D32K3* 32 (16 in/16 out) FC5A-D32S3*
*See page 20 for MIL Connector Cables and Breakout Modules.
Power
I/O Points
Input
Expandability
Power Supplies
USA: 800-262-IDEC
Canada: 888-317-IDEC
Automation Software
Operator Interfaces
FC4A-C10R2C
Power Supplies
FC4A-C10R2
100-240V AC N/A
FC4A-C16R2C
FC4A-C16R2
100-240V AC
Sensors
FC4A-C24R2C
FC4A-C24R2
100-240V AC
www.idec.com
MicroSmart Series
Output
Expandability
PLCs
FC4A-D20RK1
Operator Interfaces
FC4A-D20RS1
Automation Software
FC4A-D20K3
Transistor Sink
24V DC
24V DC (Sink/Source)
FC4A-D20S3
Transistor Source
Power Supplies
FC4A-D40K3
Transistor Sink
Sensors
FC4A-D40S3
Transistor Source
USA: 800-262-IDEC
Canada: 888-317-IDEC
MicroSmart Series
Features:
15 modules to choose from Available with Screw or MIL connectors Easy snap-on Available 8, 16 or 32 point modules Up to 512 I/O can be congured in the Pentra and 264 I/O in the MicroSmart system
PLCs
Input Modules
Operator Interfaces
Appearance Part Number Input Input Points Terminal
FC4A-N08A11
100-120V AC
Automation Software
FC4A-N08B1
Power Supplies
FC4A-N16B1
24V DC
16
Sensors
FC4A-N16B3
FC4A-N32B3
32
10
www.idec.com
MicroSmart Series
PLCs
Appearance
Part Number
Output
Output Points
Terminal
FC4A-R081
Operator Interfaces
Relay
FC4A-R161
16
Automation Software
FC4A-T08K1
Power Supplies
FC4A-T16K3
Transistor Sink
16
Sensors
FC4A-T32K3
32
USA: 800-262-IDEC
Canada: 888-317-IDEC
11
MicroSmart Series
FC4A-T08S1
Operator Interfaces
FC4A-T16S3
Transistor Source
16
Automation Software
FC4A-T32S3
32
Power Supplies
FC4A-M08BR1
8 (4 in/4 out)
Sensors
24V DC (Sink/Source)
Relay
FC4A-M24BR2
12
www.idec.com
MicroSmart Series
Modules
Appearance Part Number I/O Points Input Output Resolution Terminal
FC4A-J8C1
8 (8 inputs)
16-bit (0-50000)
Automation Software
FC4A-L03A1
3 (2 inputs, 1 output)
12-bit (0-4095)
Power Supplies
FC4A-J2A1
2 (2 inputs)
FC4A-J4CN1
4 (4 inputs)
16-bit (0-50000)
FC4A-L03AP1
3 (2 inputs, 1 output)
RTD, Thermocouple
12-bit (0-4095)
USA: 800-262-IDEC
Canada: 888-317-IDEC
13
MicroSmart Series
Modules (cont.)
PLCs
Appearance Part Number I/O Points Input Output Resolution Terminal
FC4A-J8AT1
8 (8 inputs)
Thermistor (NTC/PTC)
12-bit (0-4000)
Operator Interfaces
FC4A-K2C1
2 (2 outputs)
16-bit (0-50000)
Automation Software
FC4A-K1A1
1 (1 output)
12-bit (0-4095)
Sensors
Power Supplies
14
www.idec.com
MicroSmart Series
Remote Maintenance
Easily monitor machine conditions, change machine congurations, or upload and download user programs from anywhere, using IDEC WindLDR software over an Ethernet network. For a more graphical display and remote data archiving, OPC servers, such as IDEC WindSRV or standard SCADA software, can be used. Save time and money: -Access system parameters from your desk, conference room or home to check machine status without walking the factory oor. -If a machine is down, you no longer need to send someone with their laptop to debug or download a new user program.
PLCs
Part Numbers
Appearance Part Number Description
Operator Interfaces
FC4A-ENET
Ethernet
Automation Software
FC9Y-QS100-0
Quick Start Guide
Web Server Module for MicroSmart PLC
Alarm Messaging
Real-time updates of error status or process conditions can be sent to an email address or cellular phone. A maximum of 32 customizable messages can be predened with up to two email addresses each.
Power Supplies
O/I Connectivity
Using the IDEC Web Server Module on an Ethernet network, an IDEC PLC can be congured as a host to an IDEC operator interface. This allows the touchscreen and PLC to be in separate locations.
Sensors
Ethernet
USA: 800-262-IDEC
Canada: 888-317-IDEC
15
Operator Interfaces
FC4A-AS62M
The Actuator Sensor-interface (AS-Interface) is the simplest and most cost-effective of the PLC-based , industrial-networking protocols. AS-Interface is a truly open, low-cost electromechanical connection system designed to operate over a two-wire cable carrying data and power over a distance of up to 100m. It is especially suitable for lower levels of plant automation where simple - often binary (On/Off) - eld devices such as switches, sensors, and actuators need to interoperate in a local area automation network controlled by a PLC. IDEC supports this open technology.
Power Supplies
IDEC offers a plug-in AS-Interface master module (as well as other AS-Interface devices, please see AS-Interface Communication section) that is easy to congure; it can also connect up to 62 slaves. With this technology, youll reduce the amount of engineering needed, simplify wiring and enhance your operations; requiring less maintenance. With an average cost of savings of 15 to 40% compared with traditional cabling methods, using an IDEC AS-Interface module is the easy choice.
Master-Slave Principle
The AS-Interface master controls and monitors the status of slave devices connected to the AS-Interface bus. Normally, the AS-Interface master is connected to a PLC (sometimes called host) or a gateway. Various types of slave devices can be connected to the AS-Interface bus, including sensors, actuators, and remote I/O devices. Analog slaves can also be connected to process analog data. Slaves are available in standard slaves and A/B slaves. Standard slaves have an address of 1 through 31 in the standard address
Controller
range. A/B slaves have an address of 1A through 31A in the standard address range or 1B through 31B in the expanded address range. Among the A/B slaves, slaves with an address of 1A through 31A are called A slaves, and slaves with an address of 1B through 31B are called B slaves. (see AS-Interface Communication section for more details)
Sensors
Master
Master call A-Slaves Master call B-Slaves
Slave 1A
Slave 2A
Slave 31A
Slave 1B
Slave 2B
Slave 1A
Slave 2A
Slave 31A
Slave 1B
Slave 2B
16
www.idec.com
MicroSmart Series
Operator Interfaces
FC5A-SIF2
USA: 800-262-IDEC
Canada: 888-317-IDEC
17
PLCs
FC4A-HPH1
For mounting HMI module and communication ports with slim model CPU module (HMI module is not included)
Operator Interfaces
FC4A-PH1
HMI Module
FC4A-PM32
Automation Software
FC4A-PM64
Power Supplies
FC4A-PT1
Clock cartridge
Communication Ports
Appearance Part Number Description Terminal
FC4A-PC1
RS232C
Mini DIN
Sensors
FC4A-PC2
RS485
Mini DIN
FC4A-PC3
RS485
Screw Terminal
18
www.idec.com
MicroSmart Series
PLCs
FC4A-HPC1
RS232C
Mini DIN
FC5A-EXM1M
Operator Interfaces
FC4A-HPC2
RS485
Mini DIN
FC5A-EXM1S
Automation Software
FC4A-HPC3
RS485
Screw Terminal
FC5A-EXM2
USA: 800-262-IDEC
Canada: 888-317-IDEC
19
PLCs
Part Number
Length
Expanded Description Modem cable. Used to connect a modem to the MicroSmart RS232C port.
FC4A-KC4CA
5ft. (1.53m)
FC2A-KM1C
Operator Interfaces
FC4A-USB
6ft. (1.83m)
FC2A-KP1C
User communication cable. Used to connect RS232C equipment to the MicroSmart RS232C port. MicroSmart Pentra expansion power supply interface cable. Used to connect expansion interface master and expansion slave modules.
FC4A-KC3C
0.33ft. (100mm)
FC5A-KX1C
Automation Software
Breakout Modules
Use with 26-wire MIL connector cable Part Number BX1D-S26A Descrption 26-terminal breakout module 26-terminal touch-down terminal breakout module 20-terminal breakout module 20-terminal touch-down terminal breakout module
BX1D-T26A
BX1D-S20A
BX1D-T20A
20
www.idec.com
MicroSmart Series
PLCs
16-position right-side terminal block for FC4A-D20RS1 and FC5A-D16RS1 CPU 16-position right-side terminal block for FC4A-D20RK1 and FC5A-D16RK1 CPU 11-position terminal block for 8-pt I/O expansion modules 10-position terminal block for 16-pt I/O expansion modules 20-position connector socket for MIL connector I/O expansion modules 26-position connector socket for MIL connector CPU modules Direct mounting strips for mounting on a panel Analog voltage input cable for slim CPU 14-pt input simulator switch for 24 I/O CPU 9-pt input simulator switch for 16 I/O CPU 6-pt input simulator switch for 10 I/O CPU End clips DIN Rail (1m/3.28 long, 10.5mm height)
DIN Rail (1m/3.28 long, 7.5mm height) 2.5mm athead IDEC screwdriver MicroSmart user manual MicroSmart Pentra user manual Web Server Module user manual FC5A-SIF2 Communication Module user manual Analog I/O user manual WindLDR PLC programming software
USA: 800-262-IDEC
Canada: 888-317-IDEC
21
MicroSmart Series
PLCs
MM-SMART-10 MicroSmart MM-SMART-16 MM-SMART-20 MM-SMART-24 MM-SMART-40 MicroSmart Pentra MM-PENTRA-16 MM-PENTRA-24
Operator Interfaces
Automation Software
Power Supplies
Sensors
MicroSmart Pentra
MM-PENTRA-24-HG2F-C
30W
MM-PENTRA-16-HG3F
30W
MM-PENTRA-24-HG3F
30W
MM-PENTRA-16-HG4F
30W
MM-PENTRA-24-HG4F
1. *HG1F: Light Gray Bezel, RS232 Comm., HG2F/3F/4F: Light Gray Bezel.
30W
2. All packages come with WindLDR & WindO/I-NV2 software, programming and interface cables.
22
www.idec.com
MicroSmart Series
PLCs
Unique ladder logic programming tool designed to program all IDEC PLCs
Operator Interfaces Automation Software
Part Number
Part Number FC9Y-LP2CDW Description WindLDR PLC programming software
User-friendly Interfaces
Icon-based toolbars and drag-and-drop functionality make basic ladder programming accessible to anyone. But WindLDR also shows you how to display parameters and settings and how to input your parameters, and the built-in shortcuts and tutorials will keep you on the right track.
Power Supplies
Simple-to-use Editors
Use the tag editor to access and edit coil data. Edit comments and rung comments. Simulation mode tests your program in WindLDR to guarantee that it works the way you expected, before downloading it to your PLC.
Sensors
For more information, see the Automation Software section. Visit www.idec.com/downloads for free upgrades or a free 30-day trial version.
USA: 800-262-IDEC
Canada: 888-317-IDEC
23
MicroSmart Series
Specications
All-in-One
PLCs
Part Number Rated Voltage Allowable Voltage Range Rated Power Frequency Maximum Input Current AC Power Maximum Power Consumption DC Power Allowable Momentary Power Interruption Dielectric Strength Insulation Resistance 250mA (85V AC) 160mA (24V DC) 300mA (85V AC) 190mA (24V DC) AC Power DC Power FC5A-C10R2 FC5A-C10R2C FC5A-C16R2 FC5A-C16R2C FC5A-C24R2 FC5A-C24R2C
FC4A-C10R2 FC4A-C10R2C
FC4A-C16R2 FC4A-C16R2C
FC4A-C24R2 FC4A-C24R2C
AC power model: 100 to 240V AC, DC power model: 24V DC AC power model: 85 to 264V AC, DC power model: 20.4 to 28.8V DC (including ripple) AC power model: 50/60 Hz (47 to 63 Hz) 450mA (85V AC) 1 360mA (24V DC) 2 250mA (85V AC) 160mA (24V DC) 300mA (85V AC) 190mA (24V DC) 450mA (85V AC) 2 360mA (24V DC) 3
Operator Interfaces
FC5A-C10R2/FC4A-C10R2: 30VA (264V AC) / 20VA (100V AC) 3 FC5A-C16R2/FC4A-C16R2: 31VA (264 V AC) / 22VA (100V AC ) 3 FC5A-C24R2/FC4A-C24R2: 40VA (264V AC) / 33VA (100V AC) 1 FC5A-C10R2C/FC4A-C10R2C: 3.9W (24V DC) 4 FC5A-C16R2C/FC4A-C16R2C: 4.6W (24V DC) 4 FC5A-C24R2C/FC4A-C24R2C: 8.7W (24V DC) 2 10ms (rated power voltage) Between power and or terminals: 1500V AC, 1 minute Between I/O and or terminals: 1500V AC, 1 minute Between power and or terminals: 10 M minimum (500V DC megger) Between I/O and or terminals: 10 M minimum (500V DC megger) AC power terminals: 1.5 kV, 50 ns to 1s DC power terminals: 1.0 kV, 50 ns to 1s I/O terminals (coupling clamp): 1.5 kV, 50 ns to 1s 35A 40A UL1015 AWG22, UL1007 AWG18 0 to 55C 25 to +70C (no freezing) Level RH1 (IEC61131-2), 1 to 95% RH (no condensation) Operation: 0 to 2,000m, Transport: 0 to 3,000m 2 (IEC60664-1) Free from corrosive gases IP20 (IEC60529) UL1007, AWG16 When mounted on a DIN rail or panel surface: 2 5 to 9 Hz amplitude 3.5 mm, 9 to 150 Hz acceleration 9.8 m/s (1G), 2 hours per axis on each of three mutually perpendicular axes (IEC61131-2) 147 m/s (15G), 11ms duration, 3 shocks per axis, on three mutually perpendicular axes (IEC61131) AC: 230g DC: 240g AC: 250g DC: 260g AC: 305g DC: 310g AC: 230g DC: 240g AC: 250g DC: 260g AC: 305g DC: 310g
2
Automation Software
Noise Resistance Inrush Current Power Supply Wire Operating Temperature Storage Temperature Relative Humidity Altitude Pollution Degree Corrosion Immunity Degree of Protection Grounding Wire Vibration Resistance Shock Resistance Weight
35A
40A
Sensors
Power Supplies
1. 2. 3. 4.
CPU module (including 250mA sensor power) + 4 I/O modules CPU module + 4 I/O modules CPU module (including 250mA sensor power) CPU module (24V DC)
24
www.idec.com
MicroSmart Series
FC5A-D16RK1 FC5A-D16RS1
FC5A-D32K3 FC5A-D32S3
FC4A-D20RK1 FC4A-D20RS1
FC4A-D40K3 FC4A-D40S3
PLCs
88 advanced 62.4 KB (10,400 steps) Basic Instruction END Processing 3 83s (1,000 steps) 0.35ms
92 advanced
7 modules + additional 8 modules using the expansion power supply module 8 8 Expansion: 224 Additional: 256 16 16 Expansion: 224 Additional: 256
Operator Interfaces
12 8
Expansion: 128
12 8
Expansion: 224
24 16
Expansion: 224
2,048 points 256 points 42,000 points 6,000 points 256 points 256 points
4
1,024 points 128 points 1,300 points 100 points 100 points Internal relay, shift register, counter, data register, expansion data register Approx. 30 days (typical) at 25C after backup battery fully charged Lithium secondary battery Approx. 15 hours for charging from 0% to 90% of full charge 5 years N/A 6,000 points
Automation Software
Power failure, watchdog timer, data link connection, user program EPPROM sum check, timer/counter preset value sum check, user program RAM sum check, keep data, user program syntax, user program writing, CPU module, clock IC, I/O bus initialize, user program execution Without lter or 3 to 15ms lter (selectable in increments of 1ms) Four inputs (I2 through I5) Minimum turn on pulse width: 5s minimum Minimum turn off pulse width: 5s minimum Total 4 points Single/two-phase selectable: 100 KHz (2 points) Single-phase:100 KHz (2 points) 0 to 4294967295 (32 bits) Four inputs (I2 through I5) Minimum turn on pulse width: 40s minimum Minimum turn off pulse width: 150s minimum Total 4 points Single/two-phase selectable: 20 KHz (2 points) Single-phase: 5 KHz (2 points) 0 to 65535 (16 bits) Rotary encoder mode and adding counter mode 1 point 0 to 255 1 point 0 to 10V DC Approx. 100k 0 to 255 (8 bits) 2 points 20KHz
Power Supplies
Highspeed Counter
RS232C (maintenance communication, user communications) Possible Possible Possible Possible Possible Possible Possible Possible Possible Possible Possible Possible Possible Possible Possible Possible
1. 1 step equals 6 bytes. 2. Expandable up to 64 KB when a memory cartridge is used. 3. Not including expansion I/O service time, clock function processing time, data link processing time, and interrupt processing time. 4. Extra data registers D10000 through D49999 are enabled using WindLDR
Function Area Settings, then run-time program download cannot be used. 5. Maintenance communication, user communication, Modem communication, data link, Modbus master/slave communication (FC5A only). Note: The maximum number of relay outputs that can be turned on simulatneously is 54 including those on the CPU module.
USA: 800-262-IDEC
Canada: 888-317-IDEC
25
MicroSmart Series
All-in-One
Part Number Control System FC5A-C10R2 FC5A-C10R2C FC5A-C16R2 FC5A-C16R2C FC5A-C24R2 FC5A-C24R2C
PLCs
13.8 KB (2,300 steps) Basic Instruction END Processing 2 Input Output 0.64ms 6 4
EEPROM (10,000 times rewritable) 0.64ms 4 modules 9 7 2,048 points 128 points 2,000 points 256 points 256 points 14 10 Expansion: 64 6 4 256 points 64 points 400 points 32 points 32 points Internal relay, shift register, counter, data register Approx. 30 days (typical) at 25C after backup battery fully charged Lithium secondary battery Approx. 15 hours for charging from 0% to 90% of full charge 5 years N/A Power failure, watchdog timer, data link connection, user program EPPROM sum check, timer/counter preset value sum check, user program RAM sum check, keep data, user program syntax, user program writing, CPU module, clock IC, I/O bus initialize, user program execution Without lter or 3 to 15ms lter (selectable in increments of 1ms) Four inputs (I2 through I5) Minimum turn on pulse width: 40s minimum Minimum turn off pulse width: 150s minimum Total 4 points Single/two-phase selectable: 50KHz (1 point) Single-phase: 5KHz (3 points) 0 to 65535 (16 bits) Rotary encoder mode and adding counter mode 1 point 2 points 1 point 0 to 255 2 points Total 4 points Single/two-phase selectable: 20KHz (1 point) Single-phase: 5KHz (3 points) 100 points 100 points 9 7 4 modules 14 10 1,024 points 128 points 1,300 points Expansion: 64
Operator Interfaces
Extra Data Register Counter Timer (1-sec, 100-ms, 10-ms, 1-ms) Backup Data
Automation Software
Backup Duration RAM Backup Input Filter Catch Input/Interrupt Input High-speed Counter Battery Charging Time Battery Life Replaceability
Self-diagnostic Function
Power Supplies
Maximum Counting Frequency and High-speed Counter Points Counting Range Operation Mode Number Data Range Number Input Voltage Range Input Impedance Data Range Number Max. Frequency Output Voltage Current Overload Detection Isolation
Sensors
24V DC (+10% to -15%), 250mA N/A Isolated from the internal circuit RS232C (maintenance communication, user communication) Possible Possible Possible Possible Possible Possible Possible Possible Possible Possible Possible Possible Possible Possible Possible Possible Possible Possible Possible Possible Possible Possible Possible
Port 1 Port 2 Communication Adapter (option) 3 Clock Cartridge (option) Memory Cartridge (option) HMI Module (option)
1. 1 step equals 6 bytes. 2. Not including expansion I/O service time, clock function processing time, data link processing time, and interrupt processing time. 3. Maintenance communication, user communication, Modem communication, datalink, Modbus master/slave communication (FC5A only). Note: The maximum number of relay outputs that can be turned on simultaneously is 33 including those on the CPU module.
26
www.idec.com
MicroSmart Series
PLCs
Operator Interfaces
Input Specications
Part Number FC4A-D20K3 FC4A-D20S3 12 (12/1 common) FC5A-D16RK1 FC5A-D16RS1 8 (8/1 common) FC4A-D20RK1 FC4A-D20RS1 12 (12/1 common) 20.4 to 26.4V DC FC5A I0, I1, I3, I4, I6, I7: I2, I5, I10 to I17: FC4A I0, I1, I6, I7: I2 to I5, I10 to I27: FC5A Input Impedance FC4A 4.5mA/point (24V DC) 7mA/point (24V DC) 5mA/point (24V DC) 7mA/point (24V DC) 4.9k 3.4k 5.7k 3.4k FC5A-D32K3 FC5A-D32S3 16 (8/1 common) FC4A-D40K3 FC4A-D40S3 24 (12/1 common) FC5A-C10R2 FC5A-C16R2 FC5A-C24R2 FC5A-C10R2C FC5A-C16R2C FC5A-C24R2C FC4A-C10R2 FC4A-C16R2 FC4A-C24R2 FC4A-C10R2C FC4A-C16R2C FC4A-C24R2C 6 (6/1 common) 20.4 to 28.8V DC FC5A I0 and I1: I2 to I7, I10 to I15: FC4A I0 and I1: I2 to I7, I10 to I15: FC5A FC4A 6.4mA/point 7mA/point (24V DC) 11mA 7mA/point (24V DC) 3.7k 3.4k 2.1k 3.4k 9 (9/1 common) 14 (14/1 common)
Automation Software
I0, I1, I3, I4, I6, I7: I2 to I5, I10 to I17: I0, I1, I6, I7: I2 to I5, I10 to I17:
I0 and I1: I2 to I7, I10 to I15: I0 and I1: I2 to I7, I10 to I15:
Turn ON Time
FC5A I0, I1, I3, I4, I6, I7: I2 and I5: I10 to I17: FC4A I0, I1, I6, I7: I2 to I5: I10 to I27: FC5A I0, I1, I3, I4, I6, I7: I2 and I5: I10 to I17: FC4A I0, I1, I6, I7: I2 to I5: I10 to I27: On Mother Board Insertion Durability FL26A2MA (Oki Electric Cable)
5s + lter value 35s + lter value 40s + lter value 35s + lter value 35s + lter value 40s + lter value 5s + lter value 150s + lter value 150s + lter value 45s + lter value 150s + lter value 150s + lter value FL26A2MA (Oki Electric Cable)
FC5A I0 and I1: I2 to I7: I6, I7, I10 to I15: FC4A I0 and I1: I2 to I5: I6, I7, I10 to I15: FC5A I0 and I1: I2 to I7: I6, I7, I10 to I15: FC4A I0 and I1: I2 to I5: I6, I7, I10 to I15:
2s + lter value 35s + lter value 40s + lter value 35s + lter value 35s + lter value 40s + lter value 16s + lter value 150s + lter value 150s + lter value 45s + lter value 150s + lter value 150s + lter value
Power Supplies
Connector
Sensors
Isolation Input External Load for I/O Interconnection Single Determination Method Effect of Improper Input Connection Cable Length
Between input terminals: Photocoupler isolated Internal circuit: Not isolated Type 1 (IEC61131-2)
Not needed Static Both sinking and sourcing input signals can be connected. If any input exceeding the rated value is applied, permanent damage may be caused. 3 m in compliance with electromagnetic immunity
USA: 800-262-IDEC
Canada: 888-317-IDEC
27
MicroSmart Series
Transistor Sink and Source Output
Part Number FC5A-D16RK1 FC5A-D16RS1 2 (2/1 common) FC5A-D32K3 FC5A-D32S3 FC4A-D40K3 FC4A-D40S3 16 (8/1 common)
PLCs
No. of Outputs COM0 COM1 COM2 COM3 Output Maximum Load Current Minimum Switching Load Initial Contact Resistance Electrical Life Mechanical Life Rated Load Dielectric Strength Connector on Mother Board Connector Insertion/Removal Durability
FC5A-D16K1/D32K3 FC4A-D20K3/D20RK1/D40K3 FC5A-D16RS1/D32S3 FC4A-D20S3/D20RS1/D40S3 24V DC 20.4 to 28.8V DC 0.3A per output point 1A per common 1V maximum (voltage between COM and output terminals when output is on) 1A 0.1mA maximum 39V1V 8W L/R = 10ms (28.8V DC, 1 Hz) Sink output: 100mA maximum, 24V DC (power voltage at the +V terminal) Source output: 100mA maximum, 24V DC (power voltage at the V terminal) Between output terminal and internal circuit: Photocoupler isolated Between output terminals: Not isolated FL26A2MA (Oki Electric Cable) MC1.5/16-G3.81BK (Phoenix Contact) 100 times minimum FC5A Q0 to Q2: 5s max. Q3 to Q7, Q10 to Q17: 300s max. FC4A Q0, Q1: 5s max. Q2 to Q7, Q10 to Q17: 300s max. FC5A Q0 to Q2: 5s max. Q3 to Q7, Q10 to Q17: 300s max. FC4A Q0, Q1: 5s max. Q2 to Q7, Q10 to Q17: 300s max. FL26A2MA (Oki Electric Cable)
Load Voltage Operating Load Voltage Range Load Current Maximum Load Current Voltage Drop (ON Voltage) Inrush Current Leakage Current Clamping Voltage Maximum Lamp Load Inductive Load External Current Draw
Isolation
Connector on Mother Board Connector Insertion/ Removal Durability Turn ON Time Output Delay Turn OFF Time
Sensors
28
www.idec.com
MicroSmart Series
FC5A-D32K3/D32S3 FC4A-D40K3/D40S3
Input Voltage (V DC) 26.4 24.0 Ambient Temperature 40C Ambient Temperature 55C
FC4A-D20K3/D20S3
Input Voltage (V DC) 26.4 24.0 Ambient Temperature 40C Ambient Temperature 55C
FC4A-D20RK1/D20RS1
Input Voltage (V DC) 26.4 24.0 Ambient Temperature 55C
PLCs
All-in-One CPU
FC5A-C10R2 FC5A-C10R2C FC4A-C10R2 FC4A-C10R2C FC5A-C16R2 FC5A-C16R2C FC4A-C16R2 FC4A-C16R2C FC5A-C24R2 FC5A-C24R2C FC4A-C24R2 FC4A-C24R2C
CAUTION: When using at an operating ambient temperature above 40C, reduce the input voltage or the quantity of I/O points that turn on simultaneously.
Operator Interfaces
Automation Software
Power Supplies
COM
Internal Circuit
Output
COM ()
Internal Circuit
Input
3.3 k
Input
Internal Circuit
I2 to I15 3.3 k
Source Output
COM (+)
COM
Internal Circuit
Output
Sensors
COM
USA: 800-262-IDEC
Canada: 888-317-IDEC
29
MicroSmart Series
Communication Adapter/Module
Part Number FC4A-PC1 FC4A-HPC1 EIA RS232C FC5A: 57600bps FC4A: 19200bps Possible Possible Special cable 3 FC4A-PC2 FC4A-HPC2 EIA RS485 FC5A: 57600bps FC4A: 19200bps Possible Special cable 4 Not isolated Twisted-pair shielded cable with a minimum core wire of 0.3 mm2 85/km maximum 20/km maximum FC4A-PC3 FC4A-HPC3 EIA RS485 FC5A: 57600bps FC4A: 19200bps (38400 bps 1) Possible Possible 2 Possible Possible 200 m 31
PLCs
Standards Maximum Baud Rate Maintenance Communication User Communication Data Link Communication Half-duplex Communication Maximum Cable Length Quantity of Slave Stations Isolation between Internal Circuit and Communication Port
Operator Interfaces
Automation Software
Sensors
Power Supplies
30
www.idec.com
MicroSmart Series
FC4A-N08A11
PLCs
100 to 120V AC (50/60 Hz) 85 to 132V AC 17mA/point (120V AC, 60 Hz) 0.8k (60 Hz) 9V minimum 20V maximum 25ms 30ms Between input terminals in the same common: Not isolated Between input terminals in different commons: Isolated Between input terminals and internal circuits: Photocoupler isolated Not needed Static If any input exceeding the rated value is applied, permanent damage may be caused. MC1.5/10-G-3.81BK (Phoenix Contact)
100 times minimum 60mA (5V DC), 0mA (24V DC) 30mA (5V DC), 0mA (24V DC) 80g
Power Supplies
Internal Power Consumption (at 24V DC while all inputs ON) Weight
FC4A-TK: Transistor sink output FC4A-TS: Transistor source output 24V DC 20.4 to 28.8V DC 0.1A per point 1A per common
100 times minimum 1-wire: A1 0.5-8 WH 2-wire: A1-TWIN 20.5-8 WH 10mA (5V DC) 20mA (24V DC) 5mA (5V DC) 0mA (24V DC) 0.55W 10mA (5V DC) 40mA (24V DC) 5mA (5V DC) 0mA (24V DC) 1.03W 300s maximum 300s maximum 85g 70g 105g 20mA (5V DC) 70mA (24V DC) 10mA (5V DC) 0mA (24V DC) 1.82W
Sensors
1V maximum (voltage between COM and output terminals when output is on) 1A maximum 39V1V 8W L/R = 10ms (28.8V DC) FC4A-TK: 100mA maximum, 24V DC (power voltage at the +V terminal) FC4A-TS: 100mA maximum, 24V DC (power voltage at the V terminal) Between output terminal and internal circuit: Photocoupler isolated Between output terminals: Not isolated
Internal Power Consumption (at 24V DC while all outputs ON) Output Delay Weight Turn ON Time Turn OFF Time
Isolation
USA: 800-262-IDEC
Canada: 888-317-IDEC
31
MicroSmart Series
Relay Output Module Specications
Part Number Output Points Output Maximum Load Current Minimum Switching Load Initial Contact Resistance Electrical Life 7A per common FC4A-R081 8 (4/1 common) FC4A-R161 16 (8/1 common) 1NO (form A) 2A per point 8A per common 0.1mA/0.1V DC (reference value) 30m maximum 100,000 operations minimum (rated load 1,800 operations/hour) 20,000,000 operations minimum (no load 1,8000 operations/hour) 240V AC/2A (resistive load, inductive load cos = 0.4) 30V DC/2A (resistive load, inductive load L/R = 7ms) Between output and or terminals: 1,500V AC 1 minute Between output terminal and internal circuit: 1,500V AC, 1 minute Between output terminals (COMs): 1,500V AC, 1 minute MC1.5/11-G-3.81BK (Phoenix Contact) MC1.5/10-G-3.81BK (Phoenix Contact) 100 times minimum 1-wire: A1 0.5-8 WH 2-wire: A1-TWIN 20.5-8 WH 30mA (5V DC) 40mA (24V DC) 5mA (5V DC) 0mA (24V DC) 1.16W 110g 45mA (5V DC) 75mA (24V DC) 5mA (5V DC) 0mA (24V DC) 2.10W 145g
PLCs
Dielectric Strength Connector On Mother Board Connector Insertion/ Removal Durability Applicable Ferrule Internal Current Draw All outputs ON All outputs OFF
Internal Power Consumption (at 24V DC while all outputs ON) Weight
Power Supplies
Sensors
Input Specications
OFF Voltage ON Current OFF Current Turn ON Time Turn OFF Time Isolation External Load for I/O Interconnection Signal Determination Method Effect of Improper Input Connection Cable Length
32
www.idec.com
MicroSmart Series
Connector on Mother Board Connector Insertion/Removal Durability Internal Current Draw All I/Os ON All I/Os OFF
Input: F6018-17P (Fujicon) Output: F6018-11P (Fujicon) Not removable 65mA (5V DC), 45mA (24V DC) 10mA (5V DC), 0mA (24V DC) 1.52W 140g
Internal Power Consumption (at 24V DC while all I/Os are ON) Weight
Automation Software
FC4A-N08B1, FC4A-N16B1
Input 3.3 k
COM
Internal Circuit
Output
Power Supplies
COM ()
FC4A-N16B3/N32B3
Input Voltage (V DC) Ambient Temperature 30C 28.8 26.4 Ambient 24.0 Temperature 55C
FC4A-N08A11
Input Voltage (V AC) Ambient Temperature 55C 132 120 102
FC4A-N16B3, FC4A-N32B3
Internal Circuit
Input
4.3 k
COM
0 50 100 I/O Simultaneous ON Ratio (%) 0 50 100 I/O Simultaneous ON Ratio (%)
Internal Circuit
Output
FC4A-M08BR1
Input Voltage (V DC) 28.8 26.4 24.0 Ambient Temperature 55C
FC4A-M24BR2
Input Voltage (V DC) Ambient Temperature 45C 28.8 26.4 Ambient 24.0 Temperature 55C
FC4A-M08BR1, FC4A-M24BR2
Internal Circuit
Sensors
Input
3.3 k
COM
0 50 100 I/O Simultaneous ON Ratio (%) 0 50 100 I/O Simultaneous ON Ratio (%)
When using at an operating ambient temperature above 40C, reduce the input voltage or the quantity of I/O points that turn on simultaneously.
FC4A-N08A11
Internal Circuit
Input
COM
USA: 800-262-IDEC
Canada: 888-317-IDEC
33
MicroSmart Series
Input Circuit
+V2 +V1 15M
Multiplexer
PLCs
1 k 1 k 1 k
Input
Operator Interfaces
Output Circuit
Output Circuit
Power Voltage Allowable Voltage Range External Current Draw * Connector on Mother Board Connector Insertion/Removal Durability Applicable Ferrule Internal Current Draw 45mA (24V DC)
24V DC 20.4 to 28.8V DC 40mA (24V DC) 35mA (24V DC) 40mA (24V DC) MC1.5/11-G-3.81BK (Phoenix Contact) 100 times minimum 1 terminal: A1 0.5-8 WH, 2 terminals: A1-TWIN 20.5-8 WH 50mA (5V DC) 0.34W (at 24V DC while all I/Os are ON) 85g
Automation Software
Part Number I/O Points Power Voltage Allowable Voltage Range Connector on Mother Board
FC4A-J4CN1 4 inputs
FC4A-J8C1 8 inputs
FC4A-K2C1 2 outputs
20.4 to 28.8V DC MC1.5/11-G-3.81BK (Phoenix Contact) 100 times minimum 30mA 30mA 30mA 0mA 50mA (24V DC) 140g 40mA (24V DC) 140g 25mA (24V DC) 125g 75mA (24V DC) 110g 45mA
Power Supplies
Connector Insertion/Removal Durability Internal Current Draw External Current Draw * Weight 5V DC 24V DC
* The external current draw is the value when all the analog inputs are used and the analog output value is at 100%.
Sensors
34
www.idec.com
MicroSmart Series
Thermocouple Type K (0 to 1300C) Type J (0 to 1200C) Type T (0 to 400C) 1 M minimum 20ms maximum 20ms maximum
Resistance Thermometer Pt100 3-wire type (100 to 500C) 1 M minimum 200 maximum 1.0mA maximum
0.2% of full scale plus reference junction compensation accuracy (4C maximum) 0.006% of full scale /C 0.5% of full scale 0.2% of full scale 1% of full scale 4096 increments (12 bits) Type K: 0.325C Type J: 0.300C Type T: 0.100C
Automation Software
0.15C
Power Supplies
Maximum Temporary Deviation 3% maximum when a 500V clamp voltage is applied to the power and I/O wiring during Electrical Noise Tests Noise Resistance Input Filter Cable Crosstalk Dielectric Strength Type of Protection Effect of Improper Input Connection Maximum Permanent Allowed Overload (No Damage) Selection of Analog Input Signal Calibration or Verication to Maintain Rated Accuracy 13V DC 40mA No Twisted pair shielded cable is recommended for improved noise immunity 2 LSB maximum 500V (between input and power circuit)
Sensors
1: The 12-bit data (0 to 4095) processed in the analog I/O module can be linear-converted to a value between 32768 and 32767. The optional range designation, and analog I/O data minimum and maximum values can be selected using data registers allocated to analog I/O modules. 2: When an error is detected, a corresponding error code is stored to a data register allocated to analog I/O operating status.
USA: 800-262-IDEC
Canada: 888-317-IDEC
35
MicroSmart Series
Analog Input Specications (2)
Part Number Input Signal FC4A-J4CN1, FC4A-J8C1 Voltage Input Current Input FC4A-J4CN1 Thermocouple Type K (0 to 1300C) Type J (0 to 1200C) Type T (0 to 400C) 0.9 M minimum 5ms maximum 5ms maximum 40ms/ch + 1 scan time
FC4A-J8AT1 Resistance Thermometer Pt100, Pt1000 3-wire type (100 to 500C) Ni100, Ni1000 3-wire type (60 to 180C) 0.1mA NTC Thermistor PTC Thermistor
PLCs
Input Range
0 to 10V
Operator Interfaces
Sampling Duration Time Sampling Repetition Time Total Input System Transfer Time Input Operating Mode Conversion Method Maximum Error at 25C Input Error Plus Reference Junction Compensation Accuracy Temperature Coefcient Repeatability after Stabilization Time Non-linearity Maximum Error
FC4A-J8C1: 1ms maximum FC4A-J8C1: 1ms maximum FC4A-J8C1: 6ms/ch + 1 scan time
Single-ended input Self-scan type ADC (FC4A-J4CN1), Successive approximation register method (FC4A-J8C1, FC4A-J8AT1) 0.005% of full scale /C 2C maximum 0.005% of full scale/C 0.5% of full scale 0.04% of full scale 1% of full scale Type K: Approx. 24000 increments (15 bits) Type J: Approx. 33000 increments (15 bits) Type T: Approx. 10000 increments (14 bits) Type K: 0.058C Type J: 0.038C Type T: 0.042C Pt100: Approx. 6400 increments (13 bits) Pt1000: Approx. 64000 increments (16 bits) Ni100: Approx. 4700 increments (13 bits) Ni1000: Approx. 47000 increments (16 bits) Pt100: 0.086C Pt1000: 0.0086C Ni100: 0.037C Ni1000: 0.0037C 0.5% of full scale /C Non-linear 1% of full scale
Power Supplies
Automation Software
Digital Resolution
0.2mV
0.32A
30 Default: 0 to 4000
Sensors
Data Type in Application Program Monotonicity Input Data Out of Range Maximum Temporary Deviation during Electrical Noise Tests Input Filter Cable Crosstalk Isolation
Default: 0 to 50000 Optional: 32768 to 32767 (optional range designation) 2 Temperature: C, F Yes Detectable Accuracy is not assured when noise is applied. Software selectable Twisted pair shielded cable is recommended for improved noise immunity 2 LSB maximum Between input and power circuit: Isolated Between input and internal circuit: Photocoupler-isolated
Noise Resistance
36
www.idec.com
MicroSmart Series
PLCs
1: The 16-bit data (0 to 50000) processed in the analog I/O module can be linear-converted to a value between 32768 and 32767. The optional range designation, and analog I/O data minimum and maximum values can be selected using data registers allocated to analog I/O modules. 2: When an error is detected, a corresponding error code is stored to a data register allocated to analog I/O operating status.
0.2% of full scale 0.015% of full scale/C 0.5% of full scale 1% of full scale 0.2% of full scale 1 LSB maximum 0% 1% of full scale 50000 increments (16 bits) 0.4mV 0.32A 25000 to 25000 (voltage) 0 to 50000 (current)
Power Supplies
Sensors
Effect of Improper Output Connection Selection of Analog Output Signal Calibration or Verication to Maintain Rated Accuracy
1. The 12-bit data (0 to 4095) processed in the analog I/O module can be linear-converted to a value between 32768 and 32767. The optional range designation, and analog I/O data minimum and maximum values can be selected using data registers allocated to analog I/O modules.
USA: 800-262-IDEC
Canada: 888-317-IDEC
37
MicroSmart Series
Expansion Interface Module Specications
Part Number Rated Power Voltage Allowable Voltage Range FC5A-EXM1M (Expansion Interface Master Module) Internal power (supplied from CPU module): 90mA (5V DC) 0mA (24V DC)
Current Draw
I/O Expansion
Between CPU module and expansion interface module Connectable CPU modules: FC5A-D16RK1/D16RS1/D32K3/D32S3 Connectable I/O modules: 7 maximum Beyond the expansion interface module Connectable I/O modules: 8 digital I/O modules maximum (AC input modules are not applicable) 2 3.6ms 2.8ms Asynchronous communication (I/O refresh of I/O modules on both sides of the expansion interface module is asynchronous.) Only communication interface part is isolated 1m (FC5A-KX1C) MKDSN1.5/3-5.08-BK (Phoenix Contact) FCN-365P024-AU (Fujitsu Component) 100 times minimum 70g 135g Not isolated MSTB2.5/3-GF-5.08BK (Phoenix Contact) 100 times minimum 140g
I/O Refresh Time 3 Communication between CPU Module and Expansion Interface Module
Automation Software
Isolation from Internal Circuit EMC Compliant Cable Length Power Supply Connector Connector on Mother Board Connector Insertion/Removal Durability Connector on Mother Board Connector Insertion/Removal Durability
Power Supplies
Weight
1: Power consumption by the expansion interface module and eight I/O modules. 2: The maximum number of relay outputs that can be turned on simultaneously is 54 points. 3: Maximum I/O refresh time of the expansion interface module. D8252 stores the refresh time.
Sensors
38
www.idec.com
MicroSmart Series
PLCs
Others 4 5 4 2 5
Operator Interfaces
3 7 7 4 4 4 8 8
Automation Software
2 4 4 6 6 4 4 4 5
Power Supplies
4 6 6 6 6 6 6 5 5 4 4 4 4
USA: 800-262-IDEC
Canada: 888-317-IDEC
39
MicroSmart Series
Advanced Instructions
Slim FC5A -D16RK1, -D16RS1, -D32K3, -D32S3 FC4A -D20RK1, -D20RS1, -D40K3, -D40S3 *
PLCs
Symbol
No Operation Move Move Not Indirect Move Indirect Move Not Block Move Indirect Bit Move Indirect Bit Move Not Compare Equal To Compare Unequal To Compare Less Than Compare Greater Than Compare Less Than or Equal To Compare Greater Than or Equal To Interval Compare Greater Than or Equal to Addition Subtraction Multiplication Division Root AND Word OR Word Exclusive OR Word Shift Left Shift Right BCD Left Shift Word Shift Rotate Left Rotate Right Hex to BCD BCD to Hex Hex to ASCII ASCII to Hex BCD to ASCII ASCII to BCD Encode Decode Bit Count Alternate Output Convert Data Type Week Timer Week Table Display Digital Read Transmit 1 Transmit 2 Receive 1
Operator Interfaces Automation Software Power Supplies Sensors Communication & Networking
IMOVN BMOV IBMV IBMVN CMP= CMP< > CMP< CMP > CMP < = CMP > = ICMP > = ADD SUB MUL DIV ROOT ANDW ORW XORW SFTL SFTR BCDLS WSFT ROTL ROTR HTOB BTOH HTOA ATOH BTOA ATOB ENCO DECO BCNT ALT CVDT WKTIM WKTBL DISP DGRD TXD1 TXD2 RXD1
40
www.idec.com
MicroSmart Series
All-in-One FC5A -C10R2, C10R2C FC4A -C10R2, -C10R2C * * * * * * * * * * * * * * * * * * * * * * * * * * FC5A -C16R2, C16R2C FC4A -C16R2, -C16R2C * * * * * * * * * * * * * * * * * * * * * * * * * FC5A -C24R2, C24R2C FC4A -C24R2, -C24R2C * * * * * * * * * * * * * * * * * * * * * * * *
FC5A -D16RK1, -D16RS1, -D32K3, -D32S3 FC4A -D20RK1, -D20RS1, -D40K3, -D40S3 * * * * * * * * * * * * * * *
PLCs
Operator Interfaces Automation Software Power Supplies Sensors Communication & Networking
USA: 800-262-IDEC
Canada: 888-317-IDEC
41
MicroSmart Series
Dimensions (mm)
FC5A-D16RK1, FC4A-D20RK1,
47.5 14.6
FC5A-D16RS1 FC4A-D20RS1
70.0
PLCs
90.0
90.0
Operator Interfaces
Automation Software
90.0
90.0
Power Supplies
FC4A-N16B1, FC4A-R161
3.8 23.5 14.6 70.0
90.0
90.0
FC4A-HPH1
38.0 13.9 71.0
90.0
90.0
Sensors
FC5A-EXM2, FC4A-M24BR2
3.8 39.1 1.0 70.0
Example The gure illustrates a system setup consisting of the all-in-one 24-I/O CPU module, an 8-point relay output module, and a 16-point DC input module mounted on a 35mm-wide-DIN rail using BNL6 mounting clips.
90.0
90.0
42
www.idec.com
4.5
DIN Rail
45.0 35.0
90.0
MicroSmart Series
FC5A-EXM2 FC4A-M24BR2
6.3 39.1
2-
4.3
PLCs
90.0 83.0
2-
4.3
90.0 103.0
90.0 103.0
Operator Interfaces
90.0 103.0
68.0
3.0
3.0
3.0
95.0
.3 4
4.3
Automation Software
90.0 103.0
90.0 103.0
2-
4.3
83.0
3.0
3.0 3.0
90.0 103.0
90.0 103.0
47.5 24.1
4.3
FC4A-HPH1
38.0 20.3
2 4 .3
FC4A-HPH1
38.0 20.3
2 4 .3
90.0 103.0
Power Supplies
90.0 103.0
Sensors
Examples Mounting hole layout for FC5A-C24R2 or FC4A-C24R2 and four 23.5mm-wide I/O modules
3
Mounting hole layout from left, FC4A-HPH1, FC4A-D20K3, FC4A-N16B3, FC4AN32B3, and FC4A-M24BR2 modules
41.8 17.6 17.6 29.7
10
12.3
4.
113.0 0.2
3.0 83.0
3.0
3.0
3.0
3.0
3.0 29.7
113.0 0.2
103.0
83.0
103.0
USA: 800-262-IDEC
Canada: 888-317-IDEC
43
MicroSmart Series
Web Server
General Specications
Rated Power Voltage 24V DC 20.4 to 26.4V DC 70 mA 10 ms maximum 500V AC, 1 minute 10 M minimum (500V DC megger) DC power terminal: 1.0 kV, 50 ns to 1 s Ethernet cable: 0.5 kV, 50 ns to 1 s (coupling clamp) 4A maximum 0 to 55C 40 to +70C (no freezing) 10 to 95% (no condensation) 2 (IEC 60664-1) Free from corrosive gases IP20 (IEC60529) When mounted on a DIN rail: 5 to 9 Hz amplitude 3.5 mm 9 to 150 Hz accelaration 9.8 m/s2 (1G) 2 hours in each of 3 axes 147 m/s2 (15G), 11 ms duration 3 shocks each in 3 axes 150g Optional Major Functions Serial Interface Specications Ethernet Specications
Interface Specications
Communication RS232C <=> Ethernet conversion function Electrical characteristics: Complies with IEEE802.3 Transmission speed: 10BASE-T/100BASE-TX (Not CE compliant) Communication protocol: IP/ICMP/ARP Ethernet protocol: TCP/SMTP/HTTP/Telnet No. of TCP connections: 1 Electrical characteristics: EIA RS232C Transmission speed: 9600 to 115200 bps Synchronization: Asynchronous Communication protocol: Full duplex Transmission control: RTS/CTS, XON/OFF, None Ethernet interface: RJ45 Serial interface: Mini DIN 8-pin connector Cable Part No.: FC4A-KC3C Remote maintenance: Uploading, downloading and monitoring using WindLDR via Ethernet Web server: Congure the web server unit using Internet Explorer etc. Reading and writing PLC operands using Java applet. Web le area: 512 KB Compliant browser: Internet Explorer 6.0 or higher, Netscape Navigator 7.2 Ethernet user communication: User communication using Ethernet Message transmission: Registered outgoing message 32 message types, 63 characters maximum per message, 2 email addresses, 64 address characters maximum Utility CD: Conguration le, PLC operand monitor sample programs, sample program conguration instructions, instruction manual (English/German/Spanish/Japanese/ Chinese)
PLCs
Allowable Voltage Range Current Draw Allowable Momentary Power Interruption Dielectric Strength Insulation Resistance
Operator Interfaces
Noise Resistance Inrush Current Operating Temperature Storage Temperature Relative Humidity Pollution Degree Corrosion Immunity Degree of Protection
Connection Method
Automation Software
Vibration Resistance
Power Supplies
Connectable Devices
Programmable Controllers IDEC FC5A MicroSmart IDEC FC4A MicroSmart IDEC FC3A OpenNet Controller Operator Interface (RS232C communication with PLC through Ethernet) IDEC HG2F
Dimensions
45.0 70.0
Connector Pinout
Sensors
80.0
2.1
45.0 35.0
2 3 4 5
70.0 80.0
6 7 8
44
www.idec.com
ONC Series
PLCs
-8, 16, and 32 point cards -224 inputs and outputs, 480 with expansion power supply
Analog I/O
-up to 42 analog inputs or 14 analog outputs -0-5V, 0-10V, 5V, 10V, 4-20mA
Operator Interfaces
Memory
-16K words (8K steps) user program capacity
Automation Software
Programming Instructions
Transmit/Receive Built-in X/Y Conversion Sub-Routine Call/Return for Modular Programming Square Root 16- and 32-bit Math, Add, Sub, Mult, Div Data Conversion to/from Dec, Hex, BCD, ASCII Block Move Summation Averaging Day of Week Program Scheduling
Power Supplies
USA: 800-262-IDEC
Canada: 888-317-IDEC
45
ONC Series
Hardware Features
CPUs FC3A-CP2K FC3A-CP2S Rated Voltage Maximum Input Current Reverse Polarity Protection Operating Temperature Electrical Specications Storage Temperature Relative Humidity Vibration Resistance Shock Resistance Dielectric Strength Ground Mounting Style High-speed counter sink output High-speed counter source output 24V DC (19-30V DC, including ripple) 1.5A at 24V DC Prevents damage if incorrectly wired. 0 to +55C -25 to +70C 30 to 95% RH (non-condensing) 10 to 57 Hz, amplitude 0.075mm 57 to 150 Hz 9.8 m/sec2 (1G) 10 sweep cycles/axis (IEC 1131) 147 m/sec2 (15G), 11ms 3 shocks each in 3 axes (IEC 1131) Between power terminal and FG: 500V AC, 1 min Between I/O terminal and FG: 1500V AC, 1 min Grounding resistance 100 (maximum) 35mm DIN rail
Automation Software
Operator Interfaces
PLCs
The eighth slot must be an expansion power supply module. (Photo is only an example of the range of available modules.)
Power Supplies
Standard ONC CPU Available Instructions User Program Capacity Average Scan Time Input Output Total I/O Points Internal Relay General ONC Specications Special Internal Relay Shift Register Timer Counter Data Register Link Register Remote I/O 37 basic, 65 advanced (PID, square root, subroutine calls, etc.) 16K words ash memory 1 ms or greater 224 points (I0-I277) 224 points (Q0-Q277) Using expansion power supply: 480 I/O points 2048 (M0-M2557) 192 (M8000-M8237) 256 (R0-R255) 256 (T0-T255; 1-sec, 100-msec, 10-msec, 1-msec) 256 (C0-C255; adding, dual pulse reversible, up/down selection reversible) 8000 (D0-D7999) 256 master (L1000 - L1317), 168 slave (L100 - L127, L200 - L227, ......, L700 - L727) 512 points Yes Yes (password protected) Yes Yes Yes Yes
Sensors
Real-Time Calendar/Clock Runtime Program Protection External Run/Stop Control Power Failure Protection Self-Diagnostics Auto Start Function
46
www.idec.com
ONC Series
PLCs
FC3A-CP2S FC3A-N16B1 FC3A-N16B3 FC3A-N32B4 FC3A-N32B5 FC3A-N08A11 FC3A-AD1261 FC3A-DA1221 FC3A-R161 FC3A-R162 FC3A-T16K1 FC3A-T16K3 FC3A-T16P1 FC3A-T32K4 FC3A-T32K5 FC3A-EA1 FC3A-SX5SM1 IDEC-MBUS-CONVPCK VHR-5N VHR-10N H18-SHF-AA SHF-001T-0.8BS SVH-21T-P1.1 FC3A-KUSA1 BX1D-T40A or BX1D-S40A FC9Y-LP2CDW* WINDSRV FC2A-KC4C EM345-0
1. *For more information on WindLDR see page 23 and the Automation Software section. 2. For more information on WindSRV see the Automation Software section.
USA: 800-262-IDEC
Canada: 888-317-IDEC
47
ONC Series
PLCs
PC Communication
The ONC is programmed by our intuitive WindLDR software -use RS232 or RS485 ports -upload, download and monitor programs
Computer Link Cable 4C FC2A-KC4C 3m (9.84 ft.) long D-sub 9-pin Female Connector
Master Station
Slave Station 1
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Slave Station 2
Slave Station 31
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Operator Interfaces
Automation Software
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
1st Unit
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
2nd Unit
Power Supplies
32nd Unit
RS485
Sensors
O N
1 2 3
COM A B Z HSC ARS485 G +24V 0V OUT B
DIP Switch
Modem
Communication Flexibility
Easy connections to any R232C equipment through the user dened RS232C port 1 or 2. Built-in Hayes AT command set for direct modem dialup and pager applications.
Printer
Barcode Reader
48
www.idec.com
ONC Series
PLCs
Operator Interfaces
Features:
One card handles 5 different signal types, [5V, 10V, 0-5V, 0-10V, or 4-20mA], switch selectable Input module has 6 inputs per card, 7 cards per CPU, 42 analog input points maximum Output module has 2 outputs per card, 7 cards per CPU, 14 analog output points maximum 12-bit resolution, 0-4000 counts, count range divides evenly Fast input scan, 3ms + 1 scan time I/O error 0.6% full scale @25C Convenient input termination
Specications
Analog Points Per Card Part Number Connector Input Signal Resolution Range Input Error Output Error Conversion Time Settling Time Input Impedance Output Load Impedance Internal Current Draw Input 6 FC3A-AD1261 Removable screw terminal blocks 0-10V DC, 10V DC, 0-5V DC, 5V DC, 4-20mA 12 bits 0-4000 counts 0.6% of full scale @ 25C NA 3ms per point NA Voltage: 1 M minimum Current: 250 NA 120mA@24V DC Output 2 FC3A-DA1221 Removable screw terminal blocks 0-10V DC, 10V DC, 0-5V DC, 5V DC, 4-20mA 12 bits 0-4000 counts NA 0.6% of full scale @ 25C
Type of Protection
Analog Input Module
+V
Sensors
Voltage Output
+
Differential Amplifier V -V
Current Output
COM
USA: 800-262-IDEC
Canada: 888-317-IDEC
49
ONC Series
16-Point DC Input Modules
PLCs
Operator Interfaces
Features:
One card handles sink (NPN) or source (PNP) input signals 16 points per card, 7 cards local, 8 cards expansion, 15 cards max. per CPU 19-30V DC input voltage range Software selectable input ltering, 0-32 msec High-speed catch inputs, rst 8 points user denable, pulse detection within 20-120sec range Termination connector
-FC3A-N16B1 - removable screw terminal blocks -FC3A-N16B3 - removable nylon pin connector
Specications
Input Part Number Connector Input Voltage Range Input Voltage Current Per Point Internal Current - all inputs ON Input Impedance On/Off Voltage On/Off Time FC3A-N16B1 Screw terminal blocks 19-30V DC 24V DC 7mA 40mA 3.4k 15/5V DC 20/120s DC Sink/Source FC3A-N16B3 Nylon pins 19-30V DC 24V DC 7mA 40mA 3.4k 15/5V DC 20/120s
Automation Software
Sensors
Features:
Communication & Networking
Specications
Input Part Number Connector Input Voltage Range Input Voltage Current Per Point Internal Current - all inputs ON Input Impedance On/Off Voltage On/Off Time FC3A-N32B4 Nylon 20-28V DC 24V DC 5mA 50mA 4.7k 15/5V DC 20/120s DC Sink/Source FC3A-N32B5 Fujitsu 20-28V DC 24V DC 5mA 50mA 4.7k 15/5V DC 20/120s
One card handles sink (NPN) or source (PNP) input signals 16 points per card, 7 cards local, 8 cards expansion, 15 cards max. per CPU 20-30V DC input voltage range Software selectable input ltering, 0-32 msec High-speed catch inputs, rst 8 points user denable, pulse detection within 20-120sec range Termination connector
-FC3A-N32B4 - removable nylon pin connector -FC3A-N32B5 - Fujitsu connector
50
www.idec.com
ONC Series
PLCs
Features:
8 points per card, 7 cards local, 8 cards expansion, 15 cards max. per CPU 100-120V AC rated input voltage 85-132V AC input voltage range On/off detection set at 20ms Convenient termination connector, removable screw terminal blocks
Specications
Input Part Number Connector Input Voltage Range Input Voltage Current Per Point Internal Current - all inputs ON Input Impedance On/Off Voltage On/Off Time AC FC3A-N08A11 Removable screw terminal blocks 85-132V AC 100-120V AC 8mA 30mA 12k (60Hz)
Power Supplies
79/20V AC 20ms
Sensors
Input
USA: 800-262-IDEC
Canada: 888-317-IDEC
51
ONC Series
16-Point Relay Output Modules
PLCs
Operator Interfaces
Features:
16 points per card, 4 points per common, 15 cards max. per CPU Outputs rated 240V AC/2A or 24V DC/2A Turn On/Off delay 6-10ms 20,000,000 operations per relay minimum Termination connector
-FC3A-R161 - removable removable screw terminal blocks -FC3A-R162 - removable nylon pin connectors
Specications
Output Part Number Connector Output Voltage Current Per Point Internal Current - all inputs ON On/Off Time FC3A-R161 Removable screw terminal blocks 240V AC/24V DC 2A 170mA 6/10ms Relay Output FC3A-R162 Nylon pin 240V AC/24V DC 2A 170mA 6/10ms
Automation Software
Sensors
Features:
Communication & Networking
Specications
Output Part Number Connector Output Voltage Current Per Point Internal Current - all inputs ON On/Off Time FC3A-T16K1 Removable screw terminal blocks 19-30V DC 500mA@ 24V DC 60mA 500/500s DC Sink FC3A-T16K3 Nylon pin 19-30V DC 500mA@ 24V DC 60mA 500/500s
16 transistor sink outputs per card, 15 cards max. per CPU Outputs rated 19-30V DC/0.5A Turn On/Off delay 500sec max. Opto-isolated outputs Termination connector
-FC3A-R161 - removable removable screw terminal blocks -FC3A-R162 - removable nylon pin connectors
52
www.idec.com
ONC Series
PLCs
Operator Interfaces
Features:
16 transistor protect source outputs per card, 15 cards max. per CPU Outputs rated 19-30V DC/0.5A Turn On/Off delay 500sec max. Opto-isolated outputs Termination connector, removable screw terminal blocks
Specications
Output Part Number Connector Output Voltage Current Per Point Internal Current - all inputs ON On/Off Time DC Source FC3A-T16P1 Removable screw terminal blocks 19-30V DC 500mA @ 24V DC 70mA 500s/500s
Automation Software
Sensors
Features:
32 transistor sink outputs per card, 15 cards max. per CPU Outputs rated 20.4-27.6V DC/0.1A Turn On/Off delay 500sec max. Opto-isolated outputs Termination connector
-FC3A-T32K4 - removable nylon pin connector -FC3A-T32K5 - removable Fujitsu connector
Specications
Output Part Number Connector Output Voltage Current Per Point Internal Current - all inputs ON On/Off Time FC3A-T32K4 Nylon pin 20.4-27.6V DC 100mA@24V DC 90mA 500/500s DC Sink FC3A-T32K5
USA: 800-262-IDEC
Canada: 888-317-IDEC
53
ONC Series
Expansion Power Supply Module
PLCs
Operator Interfaces
Features:
Automation Software
Specications
Part Number Connector Input Voltage Range Input Voltage Internal Current Momentary Power Interruption FC3A-EA1 Nylon - 5 pin 19 - 30V DC (including ripple) 24V DC 30mA 10 msec (24V DC), Level PS-2 (EN61131)
Expands the ONC from 224 up to 480 I/O points Increases I/O and functional modules by 8 Comes with a cable connector and contacts Simple, easy and convenient mounting Install in the 8th slot only
Power Supplies
Power Voltage: 24V DC Inrush Current: 50A (same power source for CPU)
Fuse
Ground
Sensors
FC3A-EA1 Expansion Power Supply Module Mounting Position Mount the expansion power supply module in the eighth slot
CPU Module
7 modules (I/O and functional) 8 modules (I/O and functional) Expansion Power Supply Module A maximum of 7 functional modules can be mounted in any of 15 slots
Mount the expansion power supply module only in the eighth slot, otherwise correct allocation of I/O and link register numbers may not occur.
54
www.idec.com
ONC Series
PLCs
110
Operator Interfaces
4.5
100
Automation Software
4.5
110
100
Power Supplies
Example: the following gure illustrates a system setup consisting of a remote I/O master module, a CPU module, and three I/O modules.
195 35 55 35 35 35
110
V.24 Interface
Sensors
REMOTE OUT
idec
USA: 800-262-IDEC
Canada: 888-317-IDEC
55
When you need a product you can rely on, is easy to use, and meets safety standards, look no further than IDEC. Our SmartRelays meet all industry standard approvals including UL, CE, C-tick and ABS (American Bureau of Shipping). Plus they are FM approved for Class 1 Div 2 hazardous locations. The bottom line is IDEC SmartRelays provide the right solution for all your control needs! Why wait? Replace your complicated system of relays, timers, and counters with just one IDEC SmartRelay! These all-in-one controllers require less space in your control cabinet. And as you know, space in your panel is money in your pocket. Combine that with low maintenance and youve got a cost-effective product you can count on for all your control operations
Automation Software
Operator Interfaces
Applications
Industrial Facility Systems Housing and Building Management
Conveyor systems Elevator controls Liquid level controls Motor, pump and valve controls Water treatment and irrigation systems
Lighting controls HVAC Gate and door controls Shutter and sun blind controls Water and sprinkler systems
Power Supplies
Unique Solutions
Monitoring Systems
Sensors
56
www.idec.com
Multifunction Interface
If you prefer not to program your SmartRelay using the LCD and keypad, simply connect the interface cable to your PC and program with our WindLGC software instead. Or you can plug-in the special memory cartridge (FL1C-PM3) and have your SmartRelay operate the circuit program through the cartridge itself.
PLCs Operator Interfaces
Universal Voltages
SmartRelays are available in 12/24VDC, 24VAC/DC, and 100-240VAC/DC voltages.
DIN Rail or Surface Mountable Operational Control Buttons Backlit LCD Display
System status input, output, analog values, timers and counters can be monitored through an embedded 4x12 LCD on your SmartRelay. This allows you to display a predened message with up to 48 characters chosen from 103 special character types. You can now adjust the contrast on your display screen to your preference. Non-LCD versions are also available. IDEC SmartRelays can be programmed with just the push of a button! Control buttons can be used to program, modify and change preset parameters. The four cursor keys can also be congured as inputs if needed.
Automation Software
Digital Outputs
IDEC SmartRelays are equipped with 4 relay outputs rated at 10A/pt. A maximum of 16 outputs can be congured with this system using digital expansion modules.
Power Supplies
FM
APPROVED
EEPROM memory
Never worry about your program being lost again! With IDEC SmartRelays, your program is stored in a non-volatile EEPROM.
Integrated Functions
8 predened basic function blocks and 28 special function blocks ensure that almost all your conventional switching devices timers and counters can be replaced. Three functions include a PI controller (e.g. for temperature control), a two-stage ramp function (e.g. for the control of frequency converters) and an analog multiplexer (e.g. for light control).
Sensors
Password Protection
Concerned about your program being copied or altered? IDEC SmartRelays keep you safe with a unique password protection scheme allowing end users to access certain parameters without seeing or modifying the actual program.
Quality
IDEC means quality and dependability you can trust and our SmartRelays are no exception. Each model is UL listed, CE certied, EMC compliant, FM approved for Class 1 Div 2 hazardous locations, C-tick compliant, Lloyds Registered, and ABS approved.
USA: 800-262-IDEC
Canada: 888-317-IDEC
57
Input
Output Relay
PLCs
FL1D-H12SND
24V DC
FL1D-H12RCA
Operator Interfaces
FL1D-H12RCC
100-240V AC/DC
Input PNP
Output Relay
Automation Software
FL1D-B12RCA
FL1D-B12RCC
100-240V AC/DC
Sensors
Appearance
FL1B-J2B2
2 (2 in/0 Out)
12/24V DC
0-10V, 4-20mA
FL1D-K2B2
2 (0 in/2 Out)
24V DC
0-10V
58
www.idec.com
LonWorks Communication module contains standard network variable type (SNVT) to achieve open network communication for building automation Maximum virtual inputs/analog inputs/outputs: 16/8/12 points An external interface le (XIF extension) unique to each LonWorks module is needed to communicate through the LonWorks network and can be downloaded at www.idec.com/smartrelay
Appearance Part Number Module Input Power Total I/O
PLCs
FL1B-CL1C12
24V AC/DC
Operator Interfaces
Automation Software
FL1B-CAS2
30V DC
Starter Kits
IDEC SmartRelay Starter Kit is an economical and ideal solution for rst time IDEC SmartRelay users Package includes a base module, WindLGC programming software, programming cable, simulator switch (DC models only) and a users manual
Power Supplies
Starter Kits
Part Number SMARTSTART-BAC-D SMARTSTART-BDC-D SMARTSTART-HAC-D SMARTSTART-HDC-D Description FL1D-B12RCC, WindLGC software and programming cable FL1D-B12RCE, WindLGC software, programming cable, and simulator switch FL1D-H12RCC, WindLGC software and programming cable FL1D-H12RCE, WindLGC software, programming cable, and simulator switch
Sensors
Accessories
Part Number Users Manual FL9Y-B966-0 FL1C-PM3 FL9Y-LP1CDW FL1A-PC1 BNDN1000 BNL6 MT-101 WindLGC Software FL9Y-LP1CDW FL1B-PSP1 FL1B-Y1371-SW8 FL9Y-B966-0 FC4A-USB Description Memory cartridge, with user dened protection feature Programming Software: WindLGC Ver. 5.0 CD w/Online Manual
Programming Cable 35mm Aluminum DIN Rail, 1m/3.28ft End Clips, Prevents modules from sliding off DIN Rail Memory Cartridge Removal Tool Mounts Module Directly to Panel 8pt Input Simulator Switch, Used with 12, 24V DC Base Module Only FL1D User's Manual, Available for download at: www.idec.com/smartrelay USB to RS232 Converter, For use with "USB Only" PC's
USA: 800-262-IDEC
Canada: 888-317-IDEC
59
WindLGC is the exclusive programming software for the IDEC SmartRelay using Windows. Edit, save, and print out your programs.
Features:
Ladder programming Online Monitor Program Comparison Time Simulation Simplied connection of the functions Programs can be saved in PDF or JPG format
Operator Interfaces
Just click the function blocks you need and link function blocks for easy wiring. Devise complicated circuits using the convenient functions of WindLGC.
Part Number
Part Number Description WindLGC programming software for IDEC SmartRelay
Automation Software
FL9Y-LP1CDW
Program Comparison
Power Supplies
Ladder Programming
Sensors
For more information, see the Automation Software section. Visit www.idec.com/downloads for free upgrades or a free demo version.
60
www.idec.com
FL1D-H12RCA FL1D-B12RCA 24V AC/DC 20.4 to 26.4V AC 20.4 to 28.8V DC 47 to 63Hz 40 to 110mA (24V AC) 20 to 75mA (24V DC)
FL1D-H12RCC FL1D-B12RCC 100 to 240V AC/DC 85 to 265V AC 100 to 253V DC 47 to 63Hz 10 to 40mA (100V AC) 10 to 25mA (240V AC) 5 to 25mA (100V DC) 5 to 15mA (240V DC) 10ms (Typ.) (100V AC/DC) 20ms (Typ.) (240V AC/DC) 1.1 to 4.6VA (100V AC) 2.4 to 6.0VA (240V AC) 0.5 to 2.9W (100V DC) 1.2 to 3.6W (240V DC) 80 hours (25C) 5 sec/day maximum AC/DC 8 (I1 to I8) 0 to 265V AC 0 to 253V DC 840k < 40V AC < 30V DC 79V AC 79V DC < 0.03mA 0.08mA 100V AC: 50ms (Typ.) 240V AC: 30ms (Typ.) 100V DC: 25ms (Typ.) 240V DC: 125ms (Typ.) 100V AC: 65ms (Typ.) 240V AC: 105ms (Typ.) 100V DC: 95ms (Typ.) 240V DC: 125ms (Typ.) 100 m
PLCs
Power Supply
Operator Interfaces
Power Consumption Reverse Polarity Protection Clock Backup Duration Clock Accuracy Input Signal Input Points Analog Input Points High-speed Input 1 Analog Input Range Analog Input Error Analog Input Resolution Allowable Voltage Range Input Impedance Input Isolation OFF Voltage ON Voltage OFF Current ON Current Turn ON Time Digital Input Analog Input
0.7 to 1.3W (24V DC) Yes DC 8 (I1 to I8) 2 (I7, I8) 2 (I5, I6), 2Khz maximum 0 to 10V DC (max. rated input: 28.8V DC) 1.5 (of full scale) 10 bits (0 to 1000) 0 to 28.8V DC 3.5k 78k < 5V DC 12V DC < 0.85mA (I1 to I6) < 0.05mA (I7, I8) 2mA (I1 to I6) 0.15mA (I7, I8) 1.5ms (Typ.) (I1 to I4) 1.0ms (I5, I6) 300ms (Typ.) (I7, I8) 1.5ms (Typ.) (I1 to I4) 1.0ms (I5, I6) 300ms (Typ.) (I7, I8) 100 m 2
0.3 to 1.7W (12V DC) 0.4 to 1.8W (24V DC) Yes 80 hours (25C) 5 sec/day maximum DC 8 (I1 to I8) 2 (I7, I8) 2 (I5, I6), 2Khz maximum 0 to 10V DC (max. rated input: 28.8V DC) 1.5 (of full scale) 10 bits (0 to 1000) 0 to 28.8V DC 3.5k 76k < 5V DC 8.5 V DC < 0.85mA (I1 to I6) < 0.05mA (I7, I8) 1.5mA (I1 to I6) 0.1mA (I7, I8) 1.5ms (Typ.) (I1 to I4) 1.0ms (I5, I6) 300ms (Typ.) (I7, I8) 1.5ms (Typ.) (I1 to I4) 1.0ms (I5, I6) 300ms (Typ.) (I7, I8) 100 m 2
0.9 to 2.7VA (24V AC) 0.4 to 1.8W (24V DC) 80 hours (25C) 5 sec/day maximum AC/DC 8 (I1 to I8) 0 to 26.4V AC 0 to 28.8V DC 4.8k < 5V AC/DC 12V AC/DC < 1.0mA 2.5mA 1.5ms (Typ.)
Operating Range
1. When selecting frequency trigger function. 2. 10m when connected to analog input (twisted pair cable) Initialization Time: After power-up, the FL1D takes a maximum of 10 seconds (9 seconds without using a memory cartridge) for initialization. When initialization is complete, the FL1D can be set to RUN mode.
USA: 800-262-IDEC
Canada: 888-317-IDEC
61
PLCs
Output Points/ Contact Conguration Isolation Dielectric Strength (between power/input terminals and output terminals) Output Voltage
Operator Interfaces
0.3A
Automation Software
Minimum Switching Load Initial Contact Resistance Mechanical Life Electrical Life Mechanical Load Switching Rate Electrical Load Resistive Load/Lamp Load 3 Inductive Load
Power Supplies
3. For uorescent lamps, if the inrush current exceeds the allowable value, use an appropriate relay.
Sensors
62
www.idec.com
FL1B-M08C2R2 100 to 240V AC/DC 85 to 265V AC 100 to 253V DC 50/60Hz (47 to 63Hz) 10 to 30mA (100V AC) 10 to 20mA (240V AC) 5 to 15mA (100V DC) 5 to 10mA (240V DC) 10ms (Typ.) (100V AC/DC) 20ms (Typ.) (240V AC/DC) 1.1 to 3.5VA (100V AC) 2.4 to 4.8VA (240V AC) 0.5 to 1.8W (100V DC) 1.2 to 2.4W (240V DC) AC/DC input 4 0 to 265V AC 0 to 253V DC < 40V AC < 30V DC 79V AC 79V DC < 0.03mA 0.08mA 100V AC: 50ms (Typ.) 240V AC: 30ms (Typ.) 100V DC: 25ms (Typ.) 240V DC: 15ms (Typ.) 100V AC: 65ms (Typ.) 240V AC: 105ms (Typ.) 100V DC: 95ms (Typ.) 240V DC: 125ms (Typ.)
FL1B-J2B2 12/24V DC 10.8 to 28.8V DC 25 to 50mA 2ms (Typ.) (12V AC/DC) 5ms (Typ.) (24V AC/DC) 0.3 to 0.6W (12V DC) 0.6 to 1.2W (24V DC) Yes Analog input
PLCs
Power Supply
5ms (Typ.)
Operator Interfaces
Power Consumption Reverse Polarity Protection Input Signal Input Points Isolation Allowable Voltage Range OFF Voltage Operating Range ON Voltage OFF Current ON Current Turn ON Time Input
0.8 to 1.1W Yes DC input 4 0 to 28.8V DC < 5V DC 12V DC < 0.85mA 2mA 1.5ms (Typ.)
0.3 to 1.7W (12V DC) 0.4 to 1.8W (24V DC) Yes DC input 4 0 to 28.8V DC < 5V DC 8.5V DC < 0.85mA 1.5mA 1.5ms (Typ.)
0.9 to 2.7VA (24V AC) 0.4 to 1.8W (24V DC) AC/DC input 4 0 to 26.4V AC 0 to 28.8V DC < 5V AC/DC 12V AC/DC < 1.0mA 2.5mA 1.5ms (Typ.)
1.5ms (Typ.)
1.5ms (Typ.)
1.5ms (Typ.)
2 0 to 10V (max. rated input: 28.8V) 0 to 20mA (max. rated input: 40mA) 10 bits (0 to 1000) 1.5% (of full scale) 76k (0 to 10V) 155 to 250 (0 to 20mA) 50ms
Sensors
USA: 800-262-IDEC
Canada: 888-317-IDEC
63
PLCs
Output Points/ Contact Conguration Isolation Dielectric Strength (between power/input terminals and output terminals) Output Voltage
Operator Interfaces
0.3A
Automation Software
Output
Short-circuit Protection Minimum Switching Load Initial Contact Resistance Mechanical Life Electrical Life Analog Output Points
Yes 2 0 to 10V 10 bits (0 to 1000V) 2.5% (of full scale) 5k 50ms 10 m (twistedpair shielded cable)
Power Supplies
Analog Output Range Digital Resolution Output Error Output Impedance Analog Value Conversion Interval Wire Length
Sensors
Switching Rate
64
www.idec.com
Standard Cold: IEC60068-2-1 Hot: IEC60068-2-2 IEC60068-2-30 IEC60068-2-6 IEC60068-2-27 IEC60068-2-31 IEC60068-2-32
3
PLCs
Storage/Transportation Temperature Relative Humidity Atmospheric Pressure Operating Condition Degree of Protection Vibration Resistance Shock Resistance Drop Test Drop Test (packaged) Emission Electrostatic Discharge Electromagnetic Fields Burst Pulses Energy Carriers Single Pulse (Surge) 6 (FL1B-H12RCC, FL1B-B12RCC only) Communication Cable Terminal Style
1. 2. 3. 4. 5. 6.
795 to 1080 hPa No corrosive gas IP20 5 to 9Hz, amplitude 3.5mm 9 to 150Hz, acceleration 9.8m/s2 (1G) 147m/s2 (15G) 50mm 1m Class B Group 1 8kV air discharge 6kV contact discharge 4 10V/m 2kV (power line) 1kV (I/O signal line) 5 1kV (power line) normal 2kV (power line) common 0.5 to 2.5mm2 (one wire) 0.5 to 1.5mm2 (two wires) Finger-safe type 7
Operator Interfaces
Automation Software
No freezing No condensation Class A for AS-Interface communication module 8kV (air discharge), 4kV (contact discharge) for AS-Interface communication module 1kV (criteria A), 2kV (criteria B) for AS-Interface communication module For protection against surge noise on DC power supply types (FL1D-H12RCE/B12RCE, FL1D-H12SND, FL1D-H12RCA/B12RCA), use surge absorbers, noise cut transformers, or noise lters. 7. Tightening torque 0.4 to 0.5 Nm
Power Supplies
I/O Allocation
Input SmartRelay Input In Input In+1 Input In+2 Input In+3 SmartRelay Output Qm Output Qm+1 Output Qm+2 Output Qm+3 Output AS-Interface Input Data Bit D0 Input Data Bit D1 Input Data Bit D2 Input Data Bit D3
Sensors
1. I/O point numbers n and m of the SmartRelay are automatically allocated by the base module according to the mounted position of the AS-Interface communication module. 2. AS-Interface communication module is IP20 terminal type. 3. AS-Interface cable is connected to the terminal block.
USA: 800-262-IDEC
Canada: 888-317-IDEC
65
Network Variables
SNVT Type SNVT_obj_request: (Quantity 1) Application Request object mode Switch light, alarm, window contact, free inputs/outputs Occupancy Room temperature (C) Brightness - lightening level (lux) Position (%) Output object status Switch light, alarm, window contact, free inputs/outputs Occupancy Scheduler program Just current state
Operator Interfaces
Neuron Chip CPU Clock Frequency Transmission Distance Bus topology Free topology
Conguration Property
Automation Software
SCPT Type Conguration Property SCPTmaxSendTime: (Quantity 12) Application Send heartbeat
Variable
Block Diagram
Dimensions (mm)
Base Module
Power Supplies
L1 N I1 I2 I3 I4 I5 I6 I7 I8
35
90
RUN/STOP
Q1 2
Q2 1
Q1
Q2
Q3
Q4
Q3
Q4
35
71.5
55 60
35.5
53 58
Sensors
Base Module
Expansion Module
98
36 N
66
www.idec.com
90
Special
On-delay
1 2 & 3 4
Trg Q
T
PLCs
I1 I2 I3 I4 Q
Cycle 1 2 3 4 5 6 7 8 9 10
Trg Par
En Inv Q
TH TL
Off-delay
Trg R Q
T
Random generator
Trg R Par Trg Q Q T Starts
TH TL
En Inv Par
En Par
On-/Off-delay
NAND
1 2 3 4 & Q
Frequency trigger
Trg Q Trg Par
TH TL
Fre G-T Q
1000 SW SW
fa=5Hz 1s
fa=3Hz 1s
Fre Par
Operator Interfaces
Retentive on-delay
Trg R Q
T T
Analog trigger
Trg R Par RS Q Q
A/1 or 0 A/2
Ax Par
NAND (Edge)
NAND
I1 I2 I3 I4 Q
Cycle 1 2 3 4 5 6 7 8 9 10
Latching relay
1 2 & 3 4
S R Q S R Par Trg S R Par RS Q
Analog comparator
1000
A/1 0
1000
A/2 0
1000 200
A/1-A/2 0
Ax Ay Par
Q -200
tor =200
Automation Software
OR
1 2 3 4 1 Q
Trg Par
Trg Par
Dual-function switch
Trg Q
TL TIL T1 T TL
NOR
Series connection of normally closed contacts
Trg R Par
Trg R Par
Message texts
Q En P Par En Par Q
XOR
1 2 =1 Q
Softkey
En
Power Supplies
No1 No2 Q
12
20 12 20
8
22
20
12 20 8
Switch Q Q
Analog amplifier
MM DD Q Ax Par AQ
NOT
1
Connection of closed contact
No 02.25 No 04.15
25
25
No
Shift register
In Trg Q Dir
1 Q
Up/down counter
R Cnt Dir 3 Par 2 1
0
S1 S2 S3 S4 S5 S6 S7 S8
0 0 0 0 1 1 0 0
1 0 0 0 0 1 1 0
0 1 0 0 0 0 1 1
1 0 1 0 0 0 0 1
1 1 0 1 0 0 0 0
0 1 1 0 1 0 0 0
1 1 0 1 0 0 0 1
Sensors
Shift Up
Shift Down
PI controller
Ax Par
A/M R
OFF=On+
AX Q
/+
Dir
1 2 3
AX Q
Max SP PV Min
Mq Q
500 ms
A/M R PV Par
En Sel St Par
AQ
AQ
A Q
En Ax Par
En Sel St
Ra te te Ra
Ra
AQ
te
StSp+B B
Ra
te
AQ
100 ms
100 ms 100 ms
R En Ral Par
Analog multiplexer
h Q
En S1 S2
V1 V2 V3 0 V4 AQ
En S1 S2 Par
AQ
USA: 800-262-IDEC
Canada: 888-317-IDEC
67
Communication & Networking Sensors Power Supplies Automation Software Operator Interfaces PLCs
68
www.idec.com