C120N circuit-breakers

B, C and D curves
EN 60898/EN 61009: 10000 IEC 60947-2: 10 kA

protect
circuit protection

function

# protection of cables against overloads and


short-circuits in final distribution
# manual control and isolation

# earth leakage protection when combined


with a Vigi C120 module without
temperature derating: compliance with
standard: EN 61009 (refer to pages 90265/2)
# remote tripping, indication, by adding
auxiliaries common to the entire C60/C120
range (refer to pages 90142/2).

description

Technical data
# current rating: 63 to 125 A
# voltage rating Ue max.: 440 V AC
# insulation voltage Ui: 500 V
# impulse withstand voltage Uimp: 6 kV
# compliance with standard EN 60898:
devices accessible by unexperienced
persons
# breaking capacity:
5 as in EN 60898

# approval: IMQ
# connection:
5 flexible cables: 1.5 to 35 mm2
5 rigid cables: 1 to 50 mm2
5 terminals ensure:

type

voltage
(V)
230400

1, 2, 3, 4P

breaking cap.
Icn (A)
10000

5 as in IEC 60947.2 (Icu)


type

voltage
breaking cap.
(V)
Icu (kA)
1P
130
20
230240
10
400415
3 (1)
2, 3, 4P
230240
20
400415
10
440
6
(1) breaking capacity under 1 pole with IT isolated
neutral system (case of double fault)

# service breaking capacity


Ics =75 % Icu
# positive break indication
# fast closing ensures simultaneous closing
of poles
# electrical durability:
5 63 A: 10000 cycles (O-C)
5 80125 A: 5000 cycles (O-C)
# limitation class: 3
# mechanical durability:
20000 cycles (O-C)
# bistable fixing pawl: simplifies disassembly
# weight (g):
1P
205

90260E.fm/2

2P
410

3P
615

4P
820

- degree of protection IP2


- tightening of wide cross-section cables
- pull-out withstand of cables
- automatic guiding of cable into the correct
position
# markers:
5 4 marker clips next to the upstream
terminal
5 label holder on handle (2P, 3P, 4P)
# degree of pollution: 3 (for use in an
industrial environment)
# degree of protection:
5 open or surface mounted device: IP2
5 in a Pragma or Prisma enclosure: IP4
(IPxxD)

B curve

# magnetic trip units operate between


3 and 5 In
# protection of very long cables
# protection of networks supplied by
generators

C curve

# magnetic trip units operate between


5 and 10 In
# protection of standard networks

D curve

# magnetic trip units operate between


10 and 14 In
# protection of circuits that supply high
inrush current loads: transformers, motors,
etc.

Updated: 5/07/01

Schneider Electric

C120N circuit-breakers
B curve
EN 60898/EN 61009: 10000 IEC 60947-2: 10 kA

protect
circuit protection

catalogue numbers

type

rating
(A)

catalogue
number

width
in mod.
of 9 mm

63
80
100
125

18340
18341
18342
18343

3
3
3
3

63
80
100
125

18344
18345
18346
18347

6
6
6
6

63
80
100
125

18348
18349
18350
18351

9
9
9
9

63
80
100
125

18352
18353
18354
18355

12
12
12
12

B curve C120N
1P

2
18340

2P

1 3

2 4
18344

3P
1 3 5

2 4 6
18349

4P
1 3 5 7

2 4 6 8
18355

Schneider Electric

Updated: 5/07/01

90260E.fm/3

C120N circuit-breakers
C curve
EN 60898/EN 61009: 10000 IEC 60947-2: 10 kA

protect
circuit protection

catalogue numbers

type

rating
(A)

catalogue
number

width
in mod.
of 9 mm

63
80
100
125

18356
18357
18358
18359

3
3
3
3

63
80
100
125

18360
18361
18362
18363

6
6
6
6

63
80
100
125

18364
18365
18367
18369

9
9
9
9

63
80
100
125

18371
18372
18374
18376

12
12
12
12

C curve C120N
1P

2
18356

2P

1 3

2 4
18360

3P
1 3 5

2 4 6
18365

4P
1 3 5 7

2 4 6 8
18377

90260E.fm/4

Updated: 5/07/01

Schneider Electric

C120N circuit-breakers
D curve
EN 60898/EN 61009: 10000 IEC 60947-2: 10 kA

protect
circuit protection

catalogue numbers

type

rating
(A)

catalogue
number

width
in mod.
of 9 mm

63
80
100
125

18378
18379
18380
18381

3
3
3
3

63
80
100
125

18382
18383
18384
18385

6
6
6
6

63
80
100
125

18386
18387
18388
18389

9
9
9
9

63
80
100
125

18390
18391
18392
18393

12
12
12
12

D curve C120N
1P

2
18378

2P

1 3

2 4
18385

3P
1 3 5

2 4 6
18389

4P
1 3 5 7

2 4 6 8

18393

additional
information
Schneider Electric

auxiliaries: page 92142/2


accessories: page 91903/2
Vigi module: page 90265/2
discrimination table: page 92511/2

dimensions: page 90148/2


derating: page 92515/2
tripping curves: page 90180/2

Updated: 5/07/01

90260E.fm/5

C120H circuit-breakers
B, C and D curves
EN 60898/EN 61009: 15000 IEC 60947-2: 15 kA

protect
circuit protection

function

# protection of cables against overloads and


short-circuits in final distribution
# manual control and isolation

# earth leakege protection when combined


with a Vigi C120 module without temperature
derating: compliance with standard:
EN 61009 (refer to pages 90265/2)
# remote tripping, indication, by adding
auxiliaries common to the entire C60/C120
range (refer to pages 90142/2).

description

Technical data
# current rating: 10 to 125 A
# max. voltage rating Ue: 440 V AC
# insulation voltage Ui: 500 V
# impulse withstand voltage Uimp : 6 kV
# compliance with standard EN 60898:
devices accessible by unexperienced
persons
# breaking capacity:
5 as EN 60898

# approval: IMQ
# connection:
5 flexible cables: 1.5 to 352 mm2
5 rigid cables: 1 to 50 mm
5 terminal ensure:

type

voltage
(V)
230400

1, 2, 3, 4P

breaking cap.
Icn (A)
15000

5 as IEC 60947-2 (Icu)


type

voltage
breaking cap.
(V)
Icu (kA)
1P
130
30
230240
15
400415
4.5 (1)
2, 3, 4P
230240
30
400415
15
440
10
(1) breaking capacity under 1 pole with IT isolated
neutral system (case of double fault)

# service breaking capacity


Ics =50 % Icu
# positive break indication
# fast closing ensures simultaneous closing
of poles
# electrical durability:
5 63 A: 10000 cycles (O-C)
5 80125 A: 5000 cycles (O-C)
# limitation class: 3
# mechanical durability:
20000 cycles (O-C)
# bistable fixing pawl: simplifies diasassembly
# weight (g):
1P
205

90261E.fm/2

2P
410

3P
615

- degree of protection IP2


- tightening of wide cross-section cables
- pull-out withstand of cables
- automatic guiding of cable into the correct
position
# markers:
5 4 marker clips next to the upstream terminal
5 label holder on handle (2P, 3P, 4P)
# degree of pollution: 3 (for use in an
industrial environment)
# degree of protection:
5 open or surface mounted device: IP2
5 in a Pragma or Prisma enclosure: IP4
(IPxxD)

B curve

# magnetic trip units operate between 3 and


5 In
# protection of very long cables
# protection of networks supplied by
generators

C curve

# magnetic trip units operate between 5 and


10 In
# protection of standard networks

D curve

# magnetic trip units operate between 10 and


14 In
# protection of circuits that supply high inrush
current loads: transformers, motors, etc...

4P
820

Updated: 5/07/01

Schneider Electric

C120H circuit-breakers
B,C and D curves
EN 60898/EN 61009: 15000 IEC 60947-2 : 15 kA

protect
circuit protection

catalogue numbers

type

rating
(A)

catalogue
number

width
in mod.
of 9 mm

10
16
20
25
32
40
50
63
80
100
125

18394
18395
18396
18397
18398
18399
18400
18401
18402
18403
18404

3
3
3
3
3
3
3
3
3
3
3

10
16
20
25
32
40
50
63
80
100
125

18405
18406
18407
18408
18409
18410
18411
18412
18413
18414
18415

6
6
6
6
6
6
6
6
6
6
6

10
16
20
25
32
40
50
63
80
100
125

18416
18417
18418
18419
18420
18421
18422
18423
18424
18425
18426

9
9
9
9
9
9
9
9
9
9
9

10
16
20
25
32
40
50
63
80
100
125

18427
18428
18429
18430
18431
18432
18433
18434
18435
18436
18437

12
12
12
12
12
12
12
12
12
12
12

B curve C120H
1P

2
18394

2P

1 3

2 4
18412

3P

1 3 5

2 4 6
18424

4P

1 3 5 7

2 4 6 8
18437

Schneider Electric

Updated: 5/07/01

90261E.fm/3

C120H circuit-breakers
B,C and D curves
EN 60898/EN 61009: 15000 IEC 60947-2 : 15 kA

protect
circuit protection

catalogue numbers

type

rating
(A)

catalogue
number

width
in mod.
of 9 mm

10
16
20
25
32
40
50
63
80
100
125

18438
18439
18440
18441
18442
18443
18444
18445
18446
18447
18448

3
3
3
3
3
3
3
3
3
3
3

10
16
20
25
32
40
50
63
80
100
125

18449
18450
18451
18452
18453
18454
18455
18456
18457
18458
18459

6
6
6
6
6
6
6
6
6
6
6

10
16
20
25
32
40
50
63
80
100
125

18460
18461
18462
18463
18464
18465
18466
18467
18468
18469
18470

9
9
9
9
9
9
9
9
9
9
9

10
16
20
25
32
40
50
63
80
100
125

18471
18472
18473
18474
18475
18476
18477
18478
18479
18480
18481

12
12
12
12
12
12
12
12
12
12
12

C curve C120H
1P

2
18445

2P

1 3

2 4
18456

3P

1 3 5

2 4 6
18468

4P

1 3 5 7

2 4 6 8
18481

90261E.fm/4

Updated: 5/07/01

Schneider Electric

C120H circuit-breakers
B,C and D curves
EN 60898/EN 61009: 15000 IEC 60947-2 : 15 kA

protect
circuit protection

catalogue numbers

type

rating
(A)

catalogue
number

width
in mod.
of 9 mm

10
16
20
25
32
40
50
63
80
100
125

18482
18483
18484
18485
18486
18487
18488
18489
18490
18491
18492

3
3
3
3
3
3
3
3
3
3
3

10
16
20
25
32
40
50
63
80
100
125

18493
18494
18495
18496
18497
18498
18499
18500
18501
18502
18503

6
6
6
6
6
6
6
6
6
6
6

10
16
20
25
32
40
50
63
80
100
125

18504
18505
18506
18507
18508
18509
18510
18511
18512
18513
18514

9
9
9
9
9
9
9
9
9
9
9

10
16
20
25
32
40
50
63
80
100
125

18515
18516
18517
18518
18519
18520
18521
18522
18523
18524
18525

12
12
12
12
12
12
12
12
12
12
12

D curve C120H
1P

2
18482

2P

1 3

2 4
18500

3P

1 3 5

2 4 6
18514

4P

1 3 5 7

2 4 6 8
18525

additional
information
Schneider Electric

auxiliaries: page 92142/2


accessories: page 91903/2
Vigi module: page 90265/2
discrimination table: page 92511/2

dimensions: page 90148/2


derating: page 92515/2
tripping curves: page 90180/2

Updated: 5/07/01

90261E.fm/5