Você está na página 1de 3

Test Paper for Junior Engineers of UMG8900

HUAWEI Confidential

IBlank Filling
.1 .2 By function, UMG8900 frames can be classified into main control frame, .., service frame, and ... On the UMG8900 with more than two frames, the ..is directly connected to the central switching frame, and the other frames are connected to the ..of the central switching frame. UMG8900 has .type of frame, which are .. The frame number of the main control frame of the UMG8900 must be set to . The frame number of the external control frame of the UMG8900 must be set to .. The module use for fax service in UMG8900 is . There are .. types of cascading cable, which are ... The space between 2 cabinets is ..mm. . The dimension of UMG8900 is .height, width,.length.

.3 .4 .5 .6 .7 .8 .9

.10 UMG8900 uses .electric and ..V. .11 The frame number (frame ID) of UMG8900 is indicated by . .12 For GE cascading, Service frame connects to switching frame by ..board of service frame and ..board of switching frame. .13 For FE cascading, Service frame connects to switching frame by ..board of service frame and ..board of switching frame. .14 For TDM cascading, Service frame connects to switching frame by ..board of service frame and ..board of switching frame. .15 The board processing signaling in UMG8900 is .16 Every board of UMG8900 is defined by ID number from .. .17 The MCLK board is located in slot ..of frame.. .18 The MCLK board distributes clock signal for frame. (SSM-256, SSM32, both) .19 On the UMG8900, you can run the .. command to get configuration of UMG8900. .20 You can run the .. command to check license of UMG8900 . .21 You can run the .. command to display version of UMG8900. .22 You can run the .. command to reset board of UMG8900. .23 You can run the .. command to get ESN number of UMG8900. .24 You can run the .. command to list all IP addresses used in UMG8900. .25 You can run the .. command to make sure that IP connection is OK. .26 You can run the .. command to check clock source. .27 You can run the .. command to check connection between UMG8900 and MSOFTX3000. .28 The software name used to configure UMG8900 is .. .29 One signalling linkset has at most . signalling links.

IISingle Choice Questions


.1 Which board of the UMG8900 can provide the physical MC interface? A) WBFI B) MCMB C) MPPB D) MVPU

HUAWEI Confidential

.2 .3 .4 .5 .6 .7 .8 .9

Which board is BAM located? A) MVPB B) MCMB C) MPPB D) MOMU UMG8900 connects to MSOFTX3000 through A) directly B) L3 lanswitch C) router D) L2 lanswitch Which board of the UMG8900 can provide the physical NB interface? A) WHRB B) MCMB C) MPPB D) MVPU Which board of the UMG8900 provides the SG function in MTP3-M3UA mode? A) HRU B) PPU C) ASU and PPU D) SPF Which board of the UMG8900 can work in load-sharing mode? A) CMU B) PPU C) OMU D) TNB Which board of the UMG8900 can provide the digit collecting function? A) CMU B) OMU C) ASL D) VPU Which command use to add FRAME? A) ADD FRM B) ADD FRAME C) SET FRM D) SET FRAME Which format of the signalling point code configured in UMG8900 is? A) BIN B) DEC C) HEX D) OCT

.10 Which command use to activate MGW? A) ACT VMGW B) ACT MGW C) ACT UMG D) ACT MGC

HUAWEI Confidential

Você também pode gostar