At USFilter, our mission is to provide the products and services you need to meet your water requirements anytime, anyplace. An example of this offering is our complete line of cartridge filtration products shown in this catalog. Be it a sediment removal filter for the pretreatment of an RO system or validated submicron filtration of water WFI quality water, stop source for your worlds largest water used to manufacture USFilter is your one filtration needs. As the treatment company,
we offer a wide range of other capabilities, reliable products and services, combined with experience and technical knowledge you can trust. Give us a call so we can work with you to deliver a solution that meets your most stringent specifications. Call our 24-hour Customer Service at 800-466-7873 for information and support.
TABLE
OF
CARTRIDGE END-CAPS . . . . . . . . . . . . . . . . . . . . . . . . 2 NOMINALLY-RATED CARTRIDGES DI Gard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 ROGARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 NT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Prepure DP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Postpure PP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 ABSOLUTE-RATED CARTRIDGES NA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 WN Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 WE Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 DI Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 VH Series (Validated) . . . . . . . . . . . . . . . . . . . . . . 12 PV Series (Validated) . . . . . . . . . . . . . . . . . . . . . . 13 VENT FILTERS EA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 VP Series (Validated) . . . . . . . . . . . . . . . . . . . . . . 15 Vent Capsule . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 SPECIALTY FILTERS UF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Point-of-Use Capsule. . . . . . . . . . . . . . . . . . . . . . . 18 Pulverized Activated Carbon . . . . . . . . . . . . . . . . . 19 Granular Activated Carbon . . . . . . . . . . . . . . . . . . 20 HOUSINGS 316 Stainless Steel, Single Tube (Code F). . . . . . . . . 21 316L Stainless Steel, Single Tube (Code 0) . . . . . . . . 22 304 Stainless Steel, 5-Round, Multi-Tube . . . . . . . . . 23 304 Stainless Steel, 6-Round, Multi-Tube . . . . . . . . . 24 316 Stainless Steel, Multi-Tube . . . . . . . . . . . . . . . . 25 316L Electropolished Stainless Steel, Multi-Tube . . . . 26 Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Natural Polypropylene . . . . . . . . . . . . . . . . . . . . . 28
CONTENTS
The following table is presented as reference when ordering filter cartridges. For more detailed information, please contact our Technical Support Team at 800-875-7873 ext. 5000.
CARTRIDGE DESIGN
DESCRIPTION
CODE
10
Code 7 Style Cartridges 2-226 O-Ring locking outlet with spear assembly
227 O-rings are located externally on the cartridge. The O-ring adapter locks into the housing. Spear assembly on other end
Designed for a variety of prefiltration applications such as SDI (service deionization), reverse osmosis, and CDI (Continuous Deionization) Systems String wound type filter with your choice of cotton, industrial or surfactant-free polypropylene string over a polypropylene core Large void volume design for low-cost, reliable filtration performance with high contaminant holding capacity Continuous filter winding in 20-, 30-, and 40-inch lengths prevents by-passing or excessive pressure drops at the seams Gasketed end caps on 0.5 m rated filters for positive sealing that eliminates by-passing Surfactant-free FCPX style filter meets USP Class VI Biological Tests for Plastics requirements
CARTRIDGE SPECIFICATIONS Dimensions Diameter (OD) . . . . . . . . . . 2.5" (6.5 cm) Length (in) . . . . . . . . . . . . 9.75, 10, 19.5, 20, 29.25, 30, 40
Clean Pressure Drop (PSID)
FLOW RATE vs. INITIAL CLEAN PRESSURE DROP 4 2.0 1.6 1.2 .8 .4 0 0 1 2 3 4 5 8 12 0.5 m 16 LPM 1m 3 m 5 m .14 10 m 20 m 50 m .04 .02 .08
Materials
FCCS . . . . . . . . . . . . . . . . . Bleached white cotton fiber string media with polypropylene core FCPS . . . . . . . . . . . . . . . . . Polypropylene fiber string media with polypropylene core FCPX . . . . . . . . . . . . . . . . . Surfactant-free polypropylene fiber string media with polypropylene core NOTE: Code F cartridges (0.5 m) have santophrene end seals.
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . Maximum Differential Pressure @ 25C. . . . . Micron Ratings . . . . . . . . . . . . . . . . . . . . . . . Filtration Efficiency . . . . . . . . . . . . . . . . . . . . 140F (60C) 50 psi (3.4 bar) 0.5, 1, 3, 5, 10, 20, 50 Microns Nominal 90%
ORDERING INFORMATION Catalog Number and Description FCXX . . . . . . . . . . . . . . . . FCCS = cotton string fiber cartridge FCPS = polypropylene string fiber cartridge FCPX = surfactant-free polypropylene string fiber cartridge F. . . . . . . . . . . . . . . . . . . . Cartridge Code: F = double open end XX . . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 19 = 19.5, 20 = 20, 29 = 29.25, 30 = 30, 40 = 40 XX . . . . . . . . . . . . . . . . . . Micron Rating: S5 = 0.5m, 01 = 1 m, 03 = 3 m, 05 = 5 m, 10 = 10 m, 20 = 20 m, 50 = 50 m
To figure your order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance.
BAR
Designed for a variety of prefiltration applications such as SDI (service deionization), reverse osmosis and CDI (Continuous Deionization) Systems Graded density melt spun polypropylene media design for exceptional throughput, with high contaminant holding capacity Gasketed end caps on 1, 3 and 5 m rated filters for positive sealing that eliminates by-passing ROGARD cartridge filters meet the criteria for USP Class VI Biological Tests for Plastics, ensuring that no surfactants or coatings interfere with the application, making these cartridges ideal for use in the food and beverage industry Available in a variety of lengths and pore sizes to meet a wide range of applications
CARTRIDGE SPECIFICATIONS Dimensions Diameter (OD) . . . . . . . . . . 2.5" (6.5 cm) Length (in) . . . . . . . . . . . . 9.75, 10, 12, 19.5, 20, 30, 31, 40 .45 .4 .35 Clean Pressure Drop (PSID)
.3
12
3 m
16
20
5 m
24
28
10 m
32 LPM
20 m 25 m 50 m 75 m
.03
Materials
Media . . . . . . . . . . . . . . . . Core . . . . . . . . . . . . . . . . . O-Rings . . . . . . . . . . . . . . . Gaskets . . . . . . . . . . . . . . . Melt Blown polypropylene Integral polypropylene core Silicone o-rings Santophrene end seals 160F (70C) 50 psi (3.4 bar) 1, 3, 5, 10, 20, 25, 50, 75 microns Nominal 90%
.02
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . Maximum Differential Pressure @ 25C. . . . . Micron Ratings . . . . . . . . . . . . . . . . . . . . . . . Filtration Efficiency . . . . . . . . . . . . . . . . . . . .
ORDERING INFORMATION Catalog Number and Description FCRO. . . . . . . . . . . . . . . . . Rogard II all polypropylene depth cartridge X . . . . . . . . . . . . . . . . . . . Cartridge Code: F = double open end (1&5 m w/gasket) 0 = 2-222 o-rings (12&20", 1&5 m only) N = double open end (1, 3 & 5 m no gasket) XX . . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 12 = 12, 19 = 19.5, 20 = 20, 30 = 30, 31 = 31, 40 = 40 XX . . . . . . . . . . . . . . . . . . Micron Rating: 01 = 1 m, 03 = 3 m, 05 = 5 m, 10 = 10 m, 20 = 20 m, 25 = 25 m, 50 = 50 m, 75 = 75 m
To figure your order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance.
BAR
Designed to deliver precision prefiltration through the patented advanced melt blown CoLD technology structure that incorporates large diameter fibers for strength while maintaining small fibers for filtration CoLD fiber technology melt blown structure delivers exceptional retention, mechanical strength and on-stream life Graded pore structure throughout the filters depth provides high contaminant holding capacity High purity, 100% polypropylene construction is free of surfactants, binders and adhesives FDA listed materials of construction
CARTRIDGE SPECIFICATIONS Dimensions Diameter (OD) . . . . . . . . . . 2.5" (6.5 cm) Length (in) . . . . . . . . . . . . 9.75, 10, 20, 30, 40 7
32
36 LPM
0.5 m
Materials
Clean Pressure Drop (PSID) Cartridge . . . . . . . . . . . . . . Polypropylene caps and core Media . . . . . . . . . . . . . . . . CoLD fiber melt blown polypropylene Seals . . . . . . . . . . . . . . . . . Silicone o-rings and gaskets
6
5 3 m
.4
.3 BAR
5 m
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . 180F (82C) @ 15 psid (1.0 bar) Maximum Differential Pressure @ 30C. . . . . 60 psi (4.1 bar) Filtration Efficiency . . . . . . . . . . . . . . . . . . . . Nominal 90%
.2
.1
Sanitizing Agents
Chlorine, hydrogen peroxide
10
FLOW RATE vs. INITIAL CLEAN PRESSURE DROP ORDERING INFORMATION Catalog Number and Description FCNT . . . . . . . . . . . . . . . . . Polypropylene CoLD depth filter cartridge X . . . . . . . . . . . . . . . . . . . Cartridge Code: 1 = double open end w/ internal o-rings F = double open end (0.5 5 mm w/gasket) N = double open end (0.5 5 mm no gasket) XX . . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 20 = 20, 30 = 30, 40 = 40 XX . . . . . . . . . . . . . . . . . . Micron Rating: S5 = 0.5 m, 01 = 1 m, 03 = 3 m, 05 = 5 m, 10 = 10 m, 15 = 15 m, 20 = 20 m, 30 = 30 m, 40 = 40 m, 50 = 50 m, 75 = 75 m
To figure your order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance. CoLD is a registered trademark of Filterite Corporation.
12
16
20
24
28
32
36 LPM
.04
30 m 40 m 50 m .03 75 m
0.3 0.2
.02
BAR
0.4
Composed of graded density melt blown polypropylene depth media for high efficiency prefiltration and post-filtration of DI resin applications Prepure DP filtration cartridges feature high contaminant loading due to graded density depth filtration media construction Filter meets the criteria for USP Class VI Biological Tests for Plastics, ensuring that no surfactants or coatings interfere with the application, making these ideal for use in the food and beverage industry All materials are FDA listed for contact with food and beverages. Virgin polypropylene construction with fusion welding minimizes extractables
CARTRIDGE SPECIFICATIONS Dimensions Diameter (OD) . . . . . . . . . . 2.6" (6.6 cm) Length (in) . . . . . . . . . . . . 9.75, 10, 20, 30, 40 3.0 2.4 2.0 1.8 Clean Presure Drop (PSID) 1.6 1.4 1.2 .8 .6 .4 ORDERING INFORMATION Catalog Number and Description FCDP . . . . . . . . . . . . . . . . . All polypropylene depth filter cartridge X . . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 7 = 2-226 o-rings w/spear 1 = double open end w/internal o-rings F = double open end w/flat gasket seal XX . . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 20 = 20, 30 = 30, 40 = 40 XX . . . . . . . . . . . . . . . . . . Micron Rating: S5 = 0.5 m, 01 = 1 m, 03 = 3 m, 05 = 5 m, 10 = 10 m, 25 = 25 m, 50 = 50 m
To figure your order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance.
m
m 3
Cartridge . . . . . . . . . . . . . . Polypropylene caps, core and cage Media . . . . . . . . . . . . . . . . Non-woven melt blown polypropylene Seals . . . . . . . . . . . . . . . . . Silicone o-rings and gaskets
1 m
.14 .12
Materials
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . 140F (60C) @ 30 psid (2.1 bar) Maximum Differential Pressure @ 20C. . . . . 60 psi (4.1 bar) Filtration Efficiency . . . . . . . . . . . . . . . . . . . . Nominal 90%
0.5
.18
.10
Sanitizing Agents
Chlorine or hydrogen peroxide
m 10 m 25
50 m
.06
.04
BAR
CARTRIDGE SPECIFICATIONS
Dimensions
Diameter (OD) . . . . . . . . . . 2.6" (6.6 cm) Length (in) . . . . . . . . . . . . 10, 20, 30
32 LPM .20
0.3
Materials
Clean Pressure Drop (PSID) Cartridge . . . . . . . . . . . . . . Polypropylene caps, core and cage Media . . . . . . . . . . . . . . . . Pleated, non-woven melt blown polypropylene Seals . . . . . . . . . . . . . . . . . Silicone o-rings and gaskets
0.6
.15
Maximum Temperature . . . . . . . . . . . . . . . . . 140F (60C) @ 40 psid (2.8 bar) Maximum Differential Pressure @ 25C. . . . . 75 psi (5.1 bar) Filtration Efficiency . . . . . . . . . . . . . . . . . . . . nominal 90%
.10
.05
Sanitizing Agents
Chlorine, hydrogen peroxide, in-line with hot water (82C) for one hour, autoclaved for 20 minutes at 121C under no load conditions.
10
ORDERING INFORMATION Catalog Number and Description FCPP . . . . . . . . . . . . . . . . . All polypropylene, pleated, nominal depth filter cartridge X . . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 7 = 2-226 o-rings locking tabs w/spear 1 = double open end w/internal o-rings F = double open end w/flat gasket seal XX . . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30 XX . . . . . . . . . . . . . . . . . . Micron Rating: S3 = 0.3 m, S6 = 0.6 m, 01 =1 m, 03 = 3 m, 05 = 5 m, 10 = 10 m, 30 = 30 m
To figure your order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance.
BAR
Operating Parameters
Designed to deliver precision filtration through the patented advanced melt blown CoLD technology structure that incorporates large diameter fibers for strength while maintaining small fibers for filtration Patented CoLD fiber technology melt blown structure provides outstanding retention efficiency, mechanical strength, and long on-stream life Multi-zone design produces a gradient pore structure to provide pre- and post-filtration in a single cartridge Absolute filtration with sharp particle cutoffs deliver precise removal efficiencies High purity, 100% polypropylene construction is free of surfactants, binders and adhesives making these cartridges ideal for use in food and beverage applications
CARTRIDGE SPECIFICATIONS Dimensions Diameter (OD) . . . . . . . . . . 2.5" (6.5 cm) Length (in) . . . . . . . . . . . . 9.75, 10, 20, 30, 40 7 6 Clean Pressure Drop (PSID)
5
8
1 m
12
16
20
24
3 m
28
32
36 LPM
Materials
Cartridge . . . . . . . . . . . . . . Polypropylene caps and core Media . . . . . . . . . . . . . . . . CoLD fiber melt blown polypropylene Seals . . . . . . . . . . . . . . . . . Silicone o-rings and gaskets
5 m
.4
.3
10 m .2 15 m .1 20 m
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . 180F (82C) @ 15 psid (1.0 bar) Maximum Differential Pressure @ 30C. . . . . 60 psi (4.1 bar) Filtration Efficiency . . . . . . . . . . . . . . . . . . . . 100% Absolute
10
Sanitizing Agents
Chlorine, hydrogen peroxide
ORDERING INFORMATION Catalog Number and Description FCNA. . . . . . . . . . . . . . . . . Absolute rated CoLD depth filter cartridge Clean Pressure Drop (PSID) X . . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 7 = 2-226 o-rings w/spear 1 = double open end w/ internal o-rings F = double open end w/flat gasket seal 5 = 2-222 o-rings w/spear XX . . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 20 = 20, 30 = 30, 40 = 40 XX . . . . . . . . . . . . . . . . . . Micron Rating: S5 = 0.5 m, 01 = 1 m, 03 = 3 m, 05 = 5 m, 10 = 10 m, 15 = 15 m, 20 = 20 m, 30 = 30 m, 50 = 50 m, 70 = 70 m
To figure your order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance.
0.7 0.6
0.5
.04
.03 BAR .02 .01 0.1 0 1 2 3 4 5 6 7 8 Water Flow Rate/10" Cartridge (GPM) 9 10
24-HR CUSTOMER SERVICE: (800) 466-7873
BAR
Composed of pleated highly asymmetric polysulfone membrane over a non-woven polypropylene support layer For high flow rates and low pressure drops, absolute rated filters are designed for postfiltration in high purity water applications The highly asymmetric membrane delivers longer on-stream life than conventional membrane products High-purity construction materials are factory rinsed with DI water for quick on-stream rinse up with a minimum of throughput All polypropylene parts and thermal welding minimizes extractables All materials are FDA listed and meet criteria for USP Class VI Biological tests for plastics, ensuring that no surfactants or coatings interfere with the application
CARTRIDGE SPECIFICATIONS Dimensions Clean Pressure Drop (PSID) Diameter (OD) . . . . . . . . . . 2.6" (6.6 cm) Length (in) . . . . . . . . . . . . 9.75, 10, 20, 30, 40 3.0 2.5 2.0 1.5 1.0 0.5 0
FLOW RATE vs. INITIAL CLEAN PRESSURE DROP 4 8 12 16 0.05m 20 24 LPM 0.1m 0.2m 0.45m BAR 1 2 3 4 5 6 7
Materials
Cartridge . . . . . . . . . . . . . . Polypropylene caps, core and cage Media . . . . . . . . . . . . . . . . Single layer asymmetric hydrophilic polysulfone Seals . . . . . . . . . . . . . . . . . Silicone o-rings and gaskets
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . 203F (95C) @ 20 psid (1.4 bar) Maximum Differential Pressure @ 20C. . . . . 80 psi (5.5 bar) Filtration Efficiency . . . . . . . . . . . . . . . . . . . . 100% Absolute
Sanitizing Agents
5% Chlorine, 3% hydrogen peroxide
ORDERING INFORMATION Catalog Number and Description FCWN . . . . . . . . . . . . . . . . Filter cartridge single layer polysulfone X . . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear 1 = double open end w/ internal o-rings 7 = 2-226 o-rings w/locking tabs/spear end F = double open end w/flat gasket seal XX . . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 20 = 20, 30 = 30, 40 = 40 XX(X) . . . . . . . . . . . . . . . Micron Rating: S05 = 0.05 m, S1 = 0.1 m, S2 = 0.2 m, S4 = 0.45 m
To figure your order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance.
Composed of a double layer of integrity testable, highly asymmetric polysulfone membrane. These absolute rated filters offers superior bacteria and particle removal for high efficiency postfiltration for critical high purity water applications Long on stream life, high flow rates and low pressure drops result from the membrane asymmetry High-purity construction materials are factory flushed with DI water for quick on-stream rinse-up with a minimum of throughput All polypropylene parts and thermal welding minimizes extractables All materials are FDA listed for contact with food and beverages
CARTRIDGE SPECIFICATIONS Dimensions Clean Pressure Drop (PSID) Diameter (OD) . . . . . . . . . . 2.6" (6.6 cm) Length (in) . . . . . . . . . . . . 9.75, 10, 20, 30, 40
FLOW RATE vs. INITIAL CLEAN PRESSURE DROP 2 2.0 BAR 3.5 1.5 1.0 0.5 0 .5 1.0 1.5 2.0 2.5 3.0 0.2m 0.45m 4 6 0.02m 8 10 12 LPM 0.1m
Materials
Cartridge . . . . . . . . . . . . . . Polypropylene caps, core and cage Media . . . . . . . . . . . . . . . . Double layer asymmetric hydrophilic polysulfone Seals . . . . . . . . . . . . . . . . . Silicone o-rings and gaskets
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . 203F (95C) @ 20 psid (1.4 bar) Maximum Differential Pressure @ 20C. . . . . 80 psi (5.5 bar) Filtration Efficiency . . . . . . . . . . . . . . . . . . . . 100% Absolute
Recommended Water Flow Rates 0.02 micron. . . . . . . . . . . . 0.6 gpm/10" length (2.3 lpm/10" length) 0.1 micron. . . . . . . . . . . . . 1.2 gpm/10" length (4.5 lpm/10" length) 0.2 micron. . . . . . . . . . . . . 2.2 gpm/10" length (8.3 lpm/10" length) 0.45 micron. . . . . . . . . . . . 3.2 gpm/10" length (12.1 lpm/10" length) Sanitizing Agents
5% Chlorine or 3% hydrogen peroxide
Integrity Test
Pore Size . . . . . . . . . . . . . . 0.02 micron. . . . . . . . . . . . 0.1 micron. . . . . . . . . . . . . 0.2 micron. . . . . . . . . . . . . 0.45 micron. . . . . . . . . . . . Diffusional Flow (cc/min) @ Test Pressure per 10" length 20 @ 50 psig (3.4 bar) 24 @ 25 psig (1.7 bar) 18 @ 20 psig (1.4 bar) 15 @ 15 psig (1.0 bar)
ORDERING INFORMATION Catalog Number and Description FCWE. . . . . . . . . . . . . . . . . Filter cartridge double layer polysulfone X . . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear 1 = single open end w/ internal o-ring 7 = 2-226 o-rings w/locking tabs/spear end F = double open end w/flat gasket seal XX . . . . . . . . . . . . . . . . . . Length (in): 09 = 9.75, 10 = 10, 20 = 20, 30 = 30, 40 = 40 XX(X) . . . . . . . . . . . . . . . Micron Rating: S02 = 0.02 m, S1 = 0.1 m, S2 = 0.2 m, S4 = 0.45 m
To figure your order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance.
10
CARTRIDGE SPECIFICATIONS Dimensions Clean Pressure Drop (PSID) Diameter (OD) . . . . . . . . . . 2.75" (7.0 cm) Length (in) . . . . . . . . . . . . 10, 20, 30, 40 7 6 5 4 3 2 1 0 0
Materials
Cartridge . . . . . . . . . . . . . . Polypropylene caps, core and cage Media . . . . . . . . . . . . . . . . Hydrophilic PVDF Seals . . . . . . . . . . . . . . . . . Silicone o-rings and gaskets
0.1
0.2 BAR
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . 176F (80C) @ 25 psid (1.7 bar) Maximum Differential Pressure @ 25C. . . . . 50 psi (3.4 bar) Filtration Rating . . . . . . . . . . . . . . . . . . . . . . 100% Absolute
Sanitizing Agents
Chlorine, hydrogen peroxide
Integrity Test
Pore Size . . . . . . . . . . . Minimum Water Bubble Point 0.1 m. . . . . . . . . . . . . 70 psig ( 4.8 bar) 0.2 m. . . . . . . . . . . . . 45 psig ( 3.1 bar) Diffusional Flow (cc/min) @ Test Pressure per 10" length 20 @ 56 psig (3.8 bar) 12 @ 30 psig (2.1 bar)
ORDERING INFORMATION Catalog Number and Description FCDI . . . . . . . . . . . . . . . . . Filter cartridge Water DI X . . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear 7 = 2-226 o-rings w/locking tabs/spear end F = double open end w/flat gasket seal XX . . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30, 40 = 40 XX . . . . . . . . . . . . . . . . . . Micron Rating: S1 = 0.1 m, S2 = 0.2 m
To figure your order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance.
11
Cartridge is a validated, pleated polyethersulphone membrane over a non-woven polyester support layer Absolute rated Code 0, Code 5, Code 7 and Code 10 configurations are available in 10, 20 30, and 40-in lengths that are 100% tested in manufacturing to ensure absolute bacteria retention with typical reduction of >107/cm2 Meet current USP Class VI biological test for plastics, with a validation certificate available to support the bacteria challenge results. Contain no surfactants or coatings to interfere with your application, and the thermo-plastic construction process minimizes extractables. Supported single layer membrane ensures strength, while exhibiting low pressure drop and exceptionally high flow rates These validated cartridges can be sterilized by autoclaving
CARTRIDGE SPECIFICATIONS Dimensions Clean Pressure Drop (PSID) Diameter (OD) . . . . . . . . . . 2.75" (7.0 cm) Length (in) . . . . . . . . . . . . 10, 20, 30, 40 FLOW RATE vs. INITIAL CLEAN PRESSURE DROP 2 2.0 BAR 1.5 1.0 0.5 0 .5 1.0 1.5 2.0 2.5 3.0 0.2m 0.45m 4 6 0.1m 8 10 LPM
Materials
Cartridge . . . . . . . . . . . . . . Polypropylene, core and cage, nylon endcaps Media . . . . . . . . . . . . . . . . Polyethersulphone Seals . . . . . . . . . . . . . . . . . Silicone o-rings
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . Maximum Differential Pressure @ 25C. . . . . Filtration Rating . . . . . . . . . . . . . . . . . . . . . . Toxicity . . . . . . . . . . . . . . . . . . . . . . . . . . . . Validation . . . . . . . . . . . . . . . . . . . . . . . . . . 158F (70C) @ 25 psid (1.7 bar) 72 psi (5.0 bar) 100% Absolute Non-toxic by USP Class VI Biological test for plastics HIMA Bacterial challenge test methods (107 organisms/cm2)
Sanitizing Agents
Chlorine, hydrogen peroxide, autoclaved for 20 minutes at 121C under no load conditions.
Integrity Test
Pore Size . . . . . . . . . . . . . . . . . . . 0.1 m . . . . . . . . . . . . . . . . . . . . 0.2 m . . . . . . . . . . . . . . . . . . . . 0.45 m. . . . . . . . . . . . . . . . . . . . Minimum Water Bubble Point 31 psig 49 psig 36 psig Diffusional Flow (cc/min) @ Test Pressure per 10" length 27 @ 70 psig (4.9 bar) 16 @ 40 psig (2.7 bar) 16 @ 25 psig (1.7 bar)
ORDERING INFORMATION Catalog Number and Description FCVH . . . . . . . . . . . . . . . . . Filter cartridge pharmaceutical/validated X . . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 1 = single open end w/internal o-ring 5 = 2-222 o-rings w/spear end 7 = 2-226 o-rings w/locking tabs/spear end XX . . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30, 40 = 40 XX . . . . . . . . . . . . . . . . . . Micron Rating: S1 = 0.1 m, S2 = 0.2 m, S4 = 0.45 m
To figure your order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance.
12
Cartridge is a validated, pleated hydrophilic PVDF membrane over a non-woven polypropylene support layer Absolute rated at 0.2 m Code 0, Code 5, and Code 7 configurations are available in 10, 20 30, and 40-in lengths that are 100% tested in manufacturing to ensure absolute bacteria retention with typical titre reduction of >107/cm2 Meet current USP Class VI biological test for plastics, with a validation certificate available to support the bacteria challenge results. Contain no surfactants or coatings to interfere with your application, and the thermo-plastic construction process minimizes extractables. Supported single layer membrane ensures strength, while exhibiting low pressure drop and exceptionally high flow rates These validated cartridges can be sterilized by autoclaving
CARTRIDGE SPECIFICATIONS Dimensions Diameter (OD) . . . . . . . . . . 2.75" (7.0 cm) Length (in) . . . . . . . . . . . . 10, 20, 30, 40 FLOW RATE vs. INITIAL CLEAN PRESSURE DROP 16 20
FCPV 10S2 16
32
48
64 LPM 1.4
Materials
Cartridge . . . . . . . . . . . . . . Polypropylene caps, core and cage Media . . . . . . . . . . . . . . . . PVDF Seals . . . . . . . . . . . . . . . . . Silicone o-rings
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . Maximum Differential Pressure @ 25C. . . . . Filtration Rating . . . . . . . . . . . . . . . . . . . . . . Toxicity . . . . . . . . . . . . . . . . . . . . . . . . . . . . Validation . . . . . . . . . . . . . . . . . . . . . . . . . . 170F (80C) @ 25 psid (1.7 bar) 80 psi (5.5 bar) 100% Absolute Non-toxic by USP Class VI Biological test for plastics HIMA Bacterial challenge test methods (107 organisms/cm2)
12
FCPV 20S2
.7
8
FCPV 30S2
FCPV 40S2
Sanitizing Agents
Chlorine, hydrogen peroxide, autoclaved for 20 minutes at 121C under no load conditions.
Integrity Test
Pore Size . . . . . . . . . . . . . . . . . . . 0.2 m . . . . . . . . . . . . . . . . . . . . Minimum Water Bubble Point 45 psig ( 3.1 bar) Diffusional Flow (cc/min) @ Test Pressure per 10" length 13 @ 40 psig (3.1 bar)
20
ORDERING INFORMATION Catalog Number and Description FCPV . . . . . . . . . . . . . . . . . Filter cartridge pharmaceutical/validated X . . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear end 7 = 2-226 o-rings w/locking tabs/spear end XX . . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30, 40 = 40 S2 . . . . . . . . . . . . . . . . . . Micron Rating: S2 = 0.2 m
To figure your order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance.
13
BAR
Composed of a pleated hydrophobic highly asymmetric polysulfone membrane rated at 0.02 m absolute for sterile air filtration, storage tank venting applications Filter components meet current USP Class VI biological test for plastics Contain no surfactants or coatings to interfere with your application, and the thermo-plastic construction process minimizes extractables Asymmetric single layer membrane ensures strength, while exhibiting low pressure drop and exceptionally high flow rates Sterilized by autoclaving
CARTRIDGE SPECIFICATIONS Dimensions Diameter (OD) . . . . . . . . . . 2.6" (6.6 cm) Length (in) . . . . . . . . . . . . 10, 20, 30
Materials
Pressure Drop (PSID) Cartridge . . . . . . . . . . . . . . Polypropylene caps, core and cage Media . . . . . . . . . . . . . . . . Hydrophobic asymmetric polysulfone Seals . . . . . . . . . . . . . . . . . Silicone o-rings and gaskets
2.0 1.5
1000
2000
SLPM
3000
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . Maximum Differential Pressure @ 23C. . . . . Air Filtration Rating. . . . . . . . . . . . . . . . . . . . Toxicity . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ambient Air 60 psi (4.1 bar) 0.02 m 100% Absolute Non-toxic by USP Class VI Biological test for plastics
1.0 0.5
Sanitizing Agents
Chlorine, hydrogen peroxide or autoclaving
40
80
120
160
ORDERING INFORMATION Catalog Number and Description FCEA . . . . . . . . . . . . . . . . . Filter cartridge vent polysulfone X . . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear end 1 = double open end w/internal o-rings 7 = 2-226 o-rings w/locking tabs/spear end F = double open end w/flat gasket seal XX . . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30 S2 . . . . . . . . . . . . . . . . . . Micron Rating: S2 = 0.02 m (air)
To figure your order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance. NOTE: These filter cartridges should not be used as a combination air vent/water overflow device.
14
Composed of a pleated, hydrophobic, PTFE, Teflon membrane rated at 0.2 m absolute for sterile air filtration, storage tank venting applications Filter components meet the criteria of the USP Class VI Biological Test for Plastics These filters feature minimal pressure loss, long service life due to high void volume, and can be repeatedly steam sterilized or autoclaved Filters are integrity testable and are fully validated by bacterial challenge (HIMA)
CARTRIDGE SPECIFICATIONS Dimensions Diameter (OD) . . . . . . . . . . 2.6" (6.6 cm) Length (in) . . . . . . . . . . . . 10, 20, 30
Materials
Cartridge . . . . . . . . . . . . . . Polypropylene caps, core and cage Media . . . . . . . . . . . . . . . . Hydrophobic Teflon PTFE Seals . . . . . . . . . . . . . . . . . Silicone o-rings and gaskets
2.0
1000
2000
3000
SLPM
4000
5000
6000 .12
20" Cartridge
30" Cartridge
Operating Parameters
Maximum Temperature . . . . . . . . Ambient Air Maximum Differential Pressure @ 21C. . . . . Air Filtration Rating. . . . . . . . . . . . . . . . . . . . Toxicity . . . . . . . . . . . . . . . . . . . . . . . . . . . . Validation . . . . . . . . . . . . . . . . . . . . . . . . . . 72 psi (5.0 bar) 0.2 m Absolute Non-toxic by USP Class VI Biological test for plastics HIMA Bacterial challenge test methods (107 organisms/cm2 )
1.0
0.5
Sanitizing Agents
Chlorine, hydrogen peroxide, autoclaved for 20 minutes at 121C under no load conditions.
50
200
Integrity Test
Pore Size . . . . . . . . . . . . . . Minimum Water Bubble Point 0.2 m . . . . . . . . . . . . . . . 14 psig ( 1.0 bar) 60 IPA/40 water
ORDERING INFORMATION Catalog Number and Description FCVP . . . . . . . . . . . . . . . . . Filter cartridge vent polysulfone X . . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear end 7 = 2-226 o-rings w/locking tabs/spear end XX . . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30 S2. . . . . . . . . . . . . . . . . . . Micron Rating: S2 = 0.2 m
To figure your order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance. NOTE: These filter cartridges should not be used as a combination air vent/water overflow device.
15
Composed of a pleated hydrophobic PTFE filter membrane rated at 0.02 m absolute for small volume storage tank venting applications Convenient threaded inlet, with 1/2" NPTM inlet fitting screws into 1/2" NPTF bulkhead fitting, eliminates the need for a filter housing Hydrophobic expanded PTFE membranes are fully validated by bacterial challenge (HIMA) Filters feature thermally-bonded polypropylene cage without using adhesives to ensure low extractables 100% integrity tested in manufacturing and can be repeatedly autoclaved with steam up to 140C
CARTRIDGE SPECIFICATIONS Dimensions Diameter (OD) . . . . . . . . . . 2.2" (5.6 cm) Length (in) . . . . . . . . . . . . 5.9 (15 cm) Inner Connection . . . . . . . . 12" MNPT
250
500
SLPM
750
1000
Materials
Cartridge . . . . . . . . . . . . . . Polypropylene Media . . . . . . . . . . . . . . . . PTFE Membrane 5.0 .35
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . . Maximum Differential Pressure @ 23C. . . . . Air Filtration Rating. . . . . . . . . . . . . . . . . . . . Toxicity . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ambient Air 60 psi (4.1 bar) 0.02 m 100% Absolute Non-toxic by USP Class VI Biological test for plastics Pressure Drop (PSID)
4.0 3.0
.28 BAR
.21
Sanitizing Agents
Chlorine, Hydrogen Peroxide
2.0 1.0
.14
.07
ORDERING INFORMATION Catalog Number and Description FCVPTO6S1 Capsule Hydrophobic PTFE Filter
16
24
32
NOTE: These filter cartridges should not be used as a combination air vent/water overflow device.
16
Composed of validatable hollow fiber pleated polysulfone media with polypropylene hardware These absolute rated filters offer excellent bacteria and particle and pyrogen removal for critical pharmaceutical and life science applications, at economical costs Code 0, Code 5, and Code 7 configurations are available in 10, 20, 30 and 40-in lengths Meet current USP Class VI biological test for plastics, with a validation certificate available Contain no surfactants or coatings to interfere with your application, and thermo-plastic construction process minimizes extractables Hollow fiber construction ensures strength, while exhibiting low pressure drop and exceptionally high flow rates
CARTRIDGE SPECIFICATIONS Dimensions Diameter (OD) . . . . . . . . . . 2.9" (7.4 cm) Length (in) . . . . . . . . . . . . 10, 20, 30, 40 12 10 Clean Pressure Drop (PSID) 8 6 4 2
FLOW RATE vs. INITIAL CLEAN PRESSURE DROP 2 4 0.05 m 6 LPM 0.1 m .20
Materials
Cartridge . . . . . . . . . . . . . . Polypropylene caps and cage, polyurethane end sealant Media . . . . . . . . . . . . . . . . Polysulfone fibers Seals . . . . . . . . . . . . . . . . . Silicone o-rings
185F (85C) @ 10 psid (.7 bar) 30 psi (2 bar) @ 25C 100% Absolute Non-toxic by USP Class VI Biological test for plastics Diffusive flow test methods
0.2 m 0.5
Sanitizing Agents
Chlorine, hydrogen peroxide, autoclaved for 20 minutes at 121C under no load conditions
ORDERING INFORMATION Catalog Number and Description FCUF . . . . . . . . . . . . . . . . . Filter cartridge ultra filter X . . . . . . . . . . . . . . . . . . . Cartridge Code: 0 = 2-222 o-rings 5 = 2-222 o-rings w/spear end 1 = double open end w/internal o-rings 7 = 2-226 o-rings w/locking tabs/spear end XX . . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20, 30 = 30, 40 = 40 XX(X) . . . . . . . . . . . . . . . Micron Rating: S05 = 0.05 m, S1 = 0.1 m, S2 = 0.2 m
To figure your order number, replace the X with one of the numbered or lettered options beside it. Note: Not all part number combinations are available; consult Technical Support for assistance.
17
BAR
Operating Parameters
.10
Designed to provide absolute final filtration after laboratory water purification products or standard service deionization systems All polypropylene shell and support materials provide a non-pyrogenic filter, based on USP and LAL testing Microporous membrane is made from hydrophilic polyethersulfone, providing a bacteria retentive filter based on Pseudomonous diminuta challenge (HIMA) Integrity tested and validatable, making them ideal for microelectronic and pharmaceutical applications Disposable housings are fusion welded without adhesives to ensure low extractables
1000
1000 cm2 2.7" (6.8 cm) 6.7" (16.9)
Dimensions
Filtration Area . . . . . . . . . . . . . . . . . Diameter (OD) . . . . . . . . . . . . . . . . . Length/in (cm). . . . . . . . . . . . . . . . . 500 cm2 2.7" (6.8 cm) 4.8" (12.2)
Materials
Cartridge . . . . . . . . . . . . . Polypropylene caps, core and cage Media . . . . . . . . . . . . . . . . Pleated polyethersulfone
Operating Parameters
Maximum Temperature . . . . . . . . . . . . . . . . Maximum Op Pressure . . . . . . . . . . . . . . . . . Maximum Momentary Pressure . . . . . . . . . . . Filtration Rating . . . . . . . . . . . . . . . . . . . . . . Toxicity . . . . . . . . . . . . . . . . . . . . . . . . . . . . Validation . . . . . . . . . . . . . . . . . . . . . . . . . . 140 F (60 C) @ 30 psid (2.1 bar) 60 psid (4.1bar) @ 20 C 100 psid (7.0 bar) @ 20 C 100% Absolute Non-toxic by USP Class VI Biological test for plastics HIMA Bacterial challenge test methods (107 organisms/cm2)
500
0.04 gpm (0.16 lpm) 0.1 gpm (0.38 lpm)
1000
0.1 gpm (0.38 lpm) 0.3 gpm (1.1 lpm)
Integrity Test
Pore Size: Minimum Water Bubble Point 0.1 m . . . . . . . . . . . . . . . . . 90 psig ( 6.2 bar) 0.2 m . . . . . . . . . . . . . . . . . 45 psig ( 3.1 bar) Pore Size: Diffusional Flow (cc/min) 0.1 m . . . . . . . . . . . . . . . . . 4.0 cc/min at 50 psi (3.4 bar) 0.2 m . . . . . . . . . . . . . . . . . 4.0 cc/min at 40 psi (2.8 bar) 90 psig ( 6.2 bar) 45 psig ( 3.1 bar) <6.0 cc/min at 50 psi (3.4 bar) <6.0 cc/min at 40 psi (2.8 bar)
Sanitizing Agents
Hydrogen peroxide or autoclaved for 20 minutes at 121C ORDERING INFORMATION Catalog Number and Description FCCF . . . . . . . . . . . . . . . . . Capsule filter X . . . . . . . . . . . . . . . . . . . Effective filter area: P = 1000 cm2 electronics grade H = 500 cm2 pharmaceutical grade E = 500 cm2 electronics grade X . . . . . . . . . . . . . . . . . . . Inlet fitting: 1 = 1/4" NPTM, 2 = 1/2" NPTM X . . . . . . . . . . . . . . . . . . . Outlet fitting: 1 = 1/4" hose barb, 2 = 1/4" NPTM, 3 = 1/2" NPTM, 4 = 1/2" hose barb w/filling bell XX . . . . . . . . . . . . . . . . . . Micron rating: S1 = 0.1m, S2 = 0.2 m
18
Composed of pre-washed, finely pulverized activated carbon, encapsulated in a depth filtration media of highly purified alpha-cellulose and synthetic fibers for removing chlorine Depth-type cartridge ensures superior dirt holding capacity in sediment-laden waters to minimize premature exhaustion while it is being carbon treated Design includes a thermally bonded outer, nominal 10 micron pre-filtration layer that provides for depth filtration in one pass without carbon channeling or media migration
CARTRIDGE SPECIFICATIONS Dimensions 10" Cartridge Diameter (OD) . . . . . . . . . . 2.75" (7.0 cm) Length (in) . . . . . . . . . . . . 9.75" (24.8 cm)
20" Cartridge
2.75" (7.0 cm) 20" (50.8 cm) 2.0 gpm (7.6 lpm)
Materials
Primary filter media . . . . . . . . . . . . . . . . . . . Inner Layer Media . . . . . . . . . . . . . . . . . . . . Inner Core . . . . . . . . . . . . . . . . . . . . . . . . . . Outer Netting . . . . . . . . . . . . . . . . . . . . . . . . End Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . Pulverized, Activated Carbon Alpha Cellulose and Synthetic Fibers Polypropylene Polyolefin Low Durometer Polyethylene
Operating Parameters
Temperature Range . . . . . . 32 to 125F (0 52C)
Carbon Volume
3.7 ounces of pulverized carbon per 10" length
ORDERING INFORMATION Catalog Number and Description FCPC . . . . . . . . . . . . . . . . . Filter cartridge pulverized carbon F. . . . . . . . . . . . . . . . . . . . Cartridge Code: F = double open end w/flat gasket seal XX . . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20 10. . . . . . . . . . . . . . . . . . . Nominal micron retention rating
To figure your order number, replace the X with one of the numbered or lettered options beside it.
19
Composed of lignite-based granular activated carbon in an upflow cartridge design for removing chlorine feedwaters Cartridge is designed to allow water to enter the bottom of the cartridge, then filtered through the entire carbon bed before exiting at the top to maximize the contact time and therefore the adsorption Internal expansion pad maintains a tight, compact column to minimize channeling or bypass Nominal 20 micron post-filter reduces carbon fines as well as other suspended particles
CARTRIDGE SPECIFICATIONS Dimensions 10" Cartridge Diameter (OD) . . . . . . . . . . 2.875" (7.3 cm) Length (in) . . . . . . . . . . . . 9.75" (24.8 cm)
20" Cartridge
2.875" (7.3 cm) 20" (50.8 cm) 2.0 gpm (7.6 lpm)
Materials
Filter Media . . . . . . . . . . . . . . . . . . . . . . . . . Post filter. . . . . . . . . . . . . . . . . . . . . . . . . . . Expansion Pad Foam. . . . . . . . . . . . . . . . . . . Outer Casing . . . . . . . . . . . . . . . . . . . . . . . . End Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . Gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . Granular, Activated Carbon Spun Polypropylene Polyther/Polyurethane Polystyrene Polystyrene Buna-N
Operating Parameters
Temperature Range . . . . . . 32 to 125F (0 52C)
Carbon Volume
12 ounces of granular carbon per 10" length
ORDERING INFORMATION Catalog Number and Description FCGC . . . . . . . . . . . . . . . . . Filter cartridge granular carbon F. . . . . . . . . . . . . . . . . . . . Cartridge Code: F = flat gasket seal XX . . . . . . . . . . . . . . . . . . Length (in): 10 = 10, 20 = 20 20. . . . . . . . . . . . . . . . . . . Nominal micron retention rating
To figure your order number, replace the X with one of the numbered or lettered options beside it.
20
This single-tube cartridge filter housing is made of cast 316 stainless steel and includes 316 stainless steel shell. Housings are available to accommodate 10, 20 or 30-in Code F filter cartridges. The inlet and outlet are 3/4" NPT, and the bowl of each housing is fitted with a 1/4" NPT drain and vent plug. This cartridge filter housing is ideal for a wide variety of low flow applications requiring a high quality prefilter housing or for applications where an industrial pre-filter is used. Single tube housings accomodate 10", 20" and 30" Code F filter cartridges Housing uses 316SS for construction of the head, bowl and port plug Inlet and outlet connections are made to the housing head, allowing cartridges to be replaced without disconnecting the inlet/outlet piping Housing can be autoclaved or hot-water sanitized with the cartridges in place for your convenience
Materials
Bowl and Head. . . . . . . . . . . . . . . . . . . . . . . 316 stainless steel Port Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . 316 stainless steel O-ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ethylene Propylene
Operating Parameters
Max Operating Pressure . . . . . . . . . . . . . . . . 175 psi (12.1 bar) @ 200F (93C) Max Housing Flow Rate. . . . . . . . . . . . . . . . . 12 gpm (45.4 lpm)
Note: Housing rating only, safe operating pressure will depend on filter cartridge and gaskets used.
Connections
Inlet/Outlet . . . . . . . . . . . . . . . . . . . . . . . . . 3/4" NPT Drain. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4" NPT
Mounting
Should be mounted by rigid pipe connections or with optional mounting bracket. Allow enough clearance below bottom of housing to allow cartridge to be changed.
Flow Direction
Inlet and Outlet are cast on the housing head for user convenience. Pressure Drop (PSID) 16 14 12 10 8 6 4 2 0
ORDERING INFORMATION Catalog Number and Description ZHDFD1001 ZHDFD2001 ZHDFD3001 ZHDXDB001 10" housing 20" housing 30" housing Mounting Bracket
10
15
20
25
30
21
This single-tube cartridge filter housing is made of 316L stainless steel and includes 316 stainless steel port plugs. Housings are available to accommodate 10, 20 or 30-in Code 0 filter cartridges. The inlet and outlet are 3/4" NPT, and the bowl of each housing is fitted with a 1/4" NPT drain and vent plug. This cartridge filter housing is ideal for a wide variety of low flow applications requiring a high quality prefilter housing or for applications where an industrial pre-filter is used. Inlet and outlet connections are made to the housing head, allowing cartridges to be replaced without disconnecting the inlet/outlet piping Bowl incorporates a satin finish to help prevent bacterial build-up Housing can be autoclaved or hot-water sanitized with the cartridges in place for your convenience Two vent ports are included in the head for venting, or for the installation of pressure gauges
SYSTEM SPECIFICATIONS Dimensions 10-in Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-in Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30-in Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Length (A) 14.8" (37.5 cm) 24.8" (62.9 cm) 34.8" (88.4 cm) Width (B) 4.2 (10.5 cm) 4.2 (10.5 cm) 4.2 (10.5 cm)
Materials
Head . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316L stainless steel Bowl and Plugs. . . . . . . . . . . . . . . . . . . . . . . 316 stainless steel O-ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EPDM
Surface Finish
Head . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sand Blasted Finish Cartridge Sealing Surface . . . . . . . . . . . . . . . 32 RMS Finish Bowl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Satin Finish
Operating Parameters
Max Inlet Pressure . . . . . . . . . . . . . . . . . . . . 175 psi (12.1 bar) @ 150F(66C)
Note: Housing rating only, safe operating pressure will depend on filter cartridge and gaskets used.
Connections
Inlet/Outlet . . . . . . . . . . . . . . . . . . . . . . . . . 3/4" NPT Drain and Vent . . . . . . . . . . . . . . . . . . . . . . . 1/4" NPT
Mounting
Should be mounted by rigid pipe connections or optional mounting bracket. Allow enough clearance below bottom of housing to allow cartridge to be changed. HOUSING PRESSURE DROP vs. LIQUID FLOW RATE 20 15 10 5
Flow Direction
Pressure Drop (PSID)
Inlet and Outlet are electroetched on the housing head for user convenience.
ORDERING INFORMATION Catalog Number and Description ZHD0D1001 ZHD0D2001 ZHD0D3001 ZHDXDB001 10" housing 20" housing 30" housing Mounting Bracket
10
15
20
25
30
This multi-tube cartridge filter housing is made of durable 304 stainless steel, and is suited for general-purpose industrial and commercial filtration. These housings can accommodate Code F (DOE), Code 0 or Code 5 cartridges. Incorporates a flow baffle, which deflects incoming flow to prevent cartridge erosion. A 1/4" NPT air vent on the cover allows venting before start-up. A 3/4" NPT drain plug allows for liquid removal. Cartridges are independently sealed inside the housing and a single V-band clamp housing closure allows easy cartridge replacement. Cartridge post can be lifted out, allowing easy removal of cartridges at the bottom of the stack.
FILTER HOUSING SPECIFICATIONS Cartridge Inlet/Outlet Housing Dimensions/Inches (cm) Housing Inches (cm) A B C D 5-round 10" 5-round 20" 5-round 30" 5-round 40" 1-1/2 NPTM (3.8) 1-1/2 NPTM (3.8) 2 NPTM (5.1) 2 NPTM (5.1) 25 (64) 32.5 (85) 44 (112) 54.5 (138) 11.5 (29) 11.5 (29) 11.5 (29) 11.5 (29) 5.5 (14) 5.5 (14) 5.5 (14) 5.5 (14) 12 (30) 12 (30) 12 (30) 12 (30)
Flange Opt. E
12.75 (32) 12.75 (32) 12.75 (32) 12.75 (32)
Materials
Head, Shell, Plugs. . . . . . . . . . . . . . . . . . . . . Internals . . . . . . . . . . . . . . . . . . . . . . . . . . . Cover O-Ring . . . . . . . . . . . . . . . . . . . . . . . . Hold Down Plate Nut. . . . . . . . . . . . . . . . . . . 304 Stainless Steel 316 Stainless Steel Ethylene Propylene Polypropylene
Vent Tie Rod Nut O-Ring Cover Assembly V-Clamp Wing Nut Tank Assembly Nameplate Inlet "Warning" Decal Drain Separator Seat Plate
Operating Parameters
Maximum Operating Pressure . . . . . . . . . . . . 150 psi (10.7 bar) @ 200F (93C) Maximum Housing Flow Rates* . . . . . . . . . . . 100 gpm (378 lpm)
*Housing rating only, cartridge length and type will effect maximum flow rates
HOUSING PRESSURE DROP vs. LIQUID FLOW RATE 4.0 3.5 3.0 Pressure Drop (PSID) 2.5 2.0 1.5 1.0 0.5 0 20 40 60 80 100 120 140
5-round 10" 5-round 20" 5-round 30" 5-round 40" 5-round 10" 5-round 20" 5-round 30" 5-round 40"
1-1/2 NPT 1-1/2 NPT 2 NPT 2 NPT 1-1/2 Flange 1-1/2 Flange 2 Flange 2 Flange
2" Connection
1.5" Connection
**Flange inlet and outlet are also available; add F Suffix to part number
23
304 Stainless Steel, Multi-Tube Filter Housing with Swing Bolt Closure
This multi-tube cartridge filter housing is made of 18 gauge 304 stainless steel. Housings are available to accommodate six, 10, 20, 30 or 40-in, Code F filter cartridges. The inlet and outlet are 2" NPT. There is a 1/2" NPT drain plug, and a 1/4" NPT vent at the top of the housing. A swing bolt closure allows quick disassembly for cleaning and service. This cartridge filter housing is ideal for a wide variety of high flow applications that require an economical, high quality housing. Uses 304 stainless steel construction for maximum corrosion resistance to deliver years of dependable service A swing bolt closure allows quick disassembly for cleaning and service An air vent plug on the cover allows venting before start-up This housing accommodates liquid flow rates up to 180 gpm (681 Lpm) with operating pressures to 150 psig (10.3 bar)
FILTER HOUSING SPECIFICATIONS Cartridge Housing Dimensions/Inches (cm) Housing A B C 6-round 10" 6-round 20" 6-round 30" 6-round 40" 24 (61) 34 (86) 45 (114) 56 (142) 11.2 (28) 11.2 (28) 11.2 (28) 11.2 (28) 5.2 (13) 5.2 (13) 5.2 (13) 5.2 (13)
120. 0
Materials
Head and Shell. . . . . . . . . . . . . . . . . . . . . . . Vent and Drain Plug . . . . . . . . . . . . . . . . . . . Seat Cups. . . . . . . . . . . . . . . . . . . . . . . . . . . O-Ring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304 Stainless Steel 304 Stainless Steel 316L Stainless Steel Ethylene Propylene
Vent Head Swing Bolt Assembly O-ring Compression Seat Plate Assembly Spacer Cartridge Shell Tube Guide Bottom Seat Plate
Operating Parameters
Maximum Operating Pressure . . . . . . . . . . . . 150 psi (10.3 bar) @ 200F (93C) Max Water Flow Rate* . . . . . . . . . . . . . . . . . 120 gpm (454 Lpm)
*Housing rating only, cartridge length and type will effect maximum flow rates
120.00
Flange Option E
A
Drain Inlet
ORDERING INFORMATION Catalog Number Description Inlet/Outlet ZHGAF0610 ZHGAF0620 ZHGAF0630 ZHGAF0640 ZHGAF0610F ZHGAF0620F ZHGAF0630F ZHGAF0640F 6-round 10" 6-round 20" 6-round 30" 6-round 40" 6-round 10" 6-round 20" 6-round 30" 6-round 40" 2" NPT 2" NPT 2" NPT 2" NPT 2" flange 2" flange 2" flange 2" flange
B C Outlet
HOUSING PRESSURE DROP vs. LIQUID FLOW RATE 10.0 8.0 Pressure Drop (PSID) 6.0 4.0 2.0
30
60
90
120
150
190
120. 0
120.00
D
Vent Head Swing Bolt Assembly O-ring Compression Seat Plate Assembly Spacer Cartridge Shell Tube Guide Bottom Seat Plate Drain Inlet
This multi-tube cartridge filter housing is made of 316 stainless steel, and is suited for general-purpose industrial and commercial filtration. These housings can accommodate Code F (DOE) cartridges, and are available with 6, 12, and 21 tubes in 10, 20, 30, 40-inch lengths. Incorporates a flow baffle, which deflects incoming flow to prevent cartridge erosion. An air vent on the cover allows venting before start-up. A swing boot closure allows quick disassembly for cleaning and cartridge replacement
A
FILTER HOUSING SPECIFICATIONS Dimensions Inlet/Outlet Housing Dimensions (inches (cm) A B 6-round 10 6-round 20 6-round 30 6-round 40 12-round 30 12-round 40 21-round 30 21-round 40 2 NPTM (5.1) 2 NPTM (5.1) 2 NPTM (5.1) 2 NPTM (5.1) 3 flange (7.6) 3 flange (7.6) 4 flange (10.16) 4 flange (10.16) 24 (61) 34 (86) 45 (114) 56 (142) 56 (142) 66 (168) 57 (145) 67 (170) 11.2 (28) 11.2 (28) 11.2 (28) 11.2 (28) 31 (79) 31 (79) 31 (79) 31 (79)
B C Outlet
C
5.2 (13) 5.2 (13) 5.2 (13) 5.2 (13) 12 (30) 12 (30) 12 (30) 12 (30) 10.0 8.0 Pressure Drop (PSID) 6.0 4.0 2.0
D
10.2 (26) 10.2 (26) 10.2 (26) 10.2 (26) 12 (30) 12 (30) 16 (41) 16 (41)
Flange Option E
15 (38) 15 (38) 15 (38) 15 (38) 16.4 (42) 16.4 (42) 20.8 (53) 20.8 (53)
6-ROUND DIMENSIONS
Materials
Head, Shell, Plugs . . . . . . 316L Stainless Steel Internals . . . . . . . . . . . . 316 Stainless Steel Cover O-Ring . . . . . . . . . EDPM
30
60
90
120
150
190
2" flange 2" flange 3" flange 3" flange 4" flange 4" flange
12-round 21-round
*Housing rating only, cartridge length and type will effect maximum flow rates
100
200
300
400
25
This multi-tube cartridge filter housing is made of electropolished 316L stainless steel. Different housings are available to accommodate seven 10, 20, 30 of 40 inch, Code 5 or Code 0 filter cartridges with two 222 O-rings. The inlet and outlet are 2" NPTM, or optional 2" flange, and the bottom of each housing is fitted with a 3/4" NPTF drain plug. A V-band clamp closure allows cartridges to be changed quickly and easily. This cartridge filter housing is ideal for a wide variety of low flow applications requiring an economical yet high quality prefilter housing or for applications where industrial membrane filtration is used. Housing uses electro-polished 316L stainless steel construction that is easy to clean and provides maximum corrosion resistance Predrilled support stand allows the housing to be secured to floor or some mounting surface Housing can also accommodate Code F (DOE) cartridges, with liquid flow rates of 150 gpm, and operating pressures to 150 psig A 1/4" NPTF air vent plug on the cover allows venting before start-up
FILTER HOUSING SPECIFICATIONS Dimensions Inlet/Outlet Housing Dimensions (inches (cm) A B 7-round 10" 7-round 20" 7-round 30" 7-round 40" 2" NPTM (5.1) 2" NPTM (5.1) 2" NPTM (5.1) 2" NPTM (5.1) 25 (64) 33.5 (85) 44 (112) 54.5 (138) 11.5 (29) 11.5 (29) 11.5 (29) 11.5 (29)
C
5.5 (14) 5.5 (14) 5.5 (14) 5.5 (14)
D
12 (30) 12 (30) 12 (30) 12 (30)
Flange Option E
12.8" (32) 12.8" (32) 12.8" (32) 12.8" (32)
Materials
Head and Shell. . . . . . . . . . . . . . . . . . . . . . . Vent and Drain Plug . . . . . . . . . . . . . . . . . . . Seat Cups. . . . . . . . . . . . . . . . . . . . . . . . . . . O-Ring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316L Stainless Steel electropolished 316 Stainless Steel 316L Stainless Steel Ethylene Propylene
Tie Rod Nut O-Ring
Operating Parameters
Maximum Operating Pressure . . . . . . . . . . . . 150 psi (10.3 bar) @ 93F (200C) Maximum Water Flow Rate* . . . . . . . . . . . . . 140 gpm (528 Lpm)
*Housing rating only, cartridge length and type will effect maximum flow rates
ORDERING INFORMATION Catalog Number Description ZHH000710 ZHH000720 ZHH000730 ZHH000740 ZHH000710F ZHH000720F ZHH000730F ZHH000740F 7-round 10" 7-round 20" 7-round 30" 7-round 40" 7-round 10" 7-round 20" 7-round 30" 7-round 40"
Outlet
Inlet/Outlet
2" NPTM 2" NPTM 2" NPTM 2" NPTM 2" flange 2" flange 2" flange 2" flange Pressure Drop (PSID) 10 8 6 4 2 FLOW RATE vs. INITIAL CLEAN PRESSURE DROP 12
30
60
These filter housings are molded from polypropylene, and are available in 10- and 20-inch lengths. Housings are supplied with 3/4" inlet and outlets in standard flat gasket design for Code F filter cartridges. Durable housings are made from all polypropylene materials Housings are autoclavable, ETO sterilizable, and hydrogen peroxide compatible Supplied with 3/4" NPT inlet and outlets in standard flat gasket design for Code F filter cartridges
FILTER HOUSING SPECIFICATIONS Dimensions 10" Cartridge Diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2" (13.2 cm) Length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.2" (31 cm)
20" Cartridge
5.2" (13.2 cm) 22.4" (57 cm) 16 gpm (60 lpm)
Materials
Polypropylene cap and housing with standard BUNA-N o-rings
Operating Parameters
Maximum Operating Pressure . . . . . . . . . . . . . . . . . 125 psi (8.6 bar) Maximum Operating Temperature . . . . . . . . . . . . . . 100F (38C) Sterilization/Sanitization Hydrogen Peroxide. . . . . . . 7.5% compatibility; static soak up to 24 hr at ambient temperature
Weight
10" housing . . . . . . . . . . . . . . . . . . . . . . . . . 3 lb (1.4 kg) 20" housing . . . . . . . . . . . . . . . . . . . . . . . . . 4.25 lb (1.9 kg)
ORDERING INFORMATION Catalog Number and Description ZHC F A XX 01 Polypropylene filter housing Cartridge Code: F = Code F A = No plugs Length (in): 10 = 10, 20 = 20 01 = 1 tube
27
These filter housings are molded from natural, high-density polypropylene, and are available in 10-, 12- and 20-inch lengths. Housings are molded in dies that are minutely polished for an ultra-smooth finish to all contact surfaces, thus minimizing the opportunity for bacteria adhesion. Housings are supplied with 3/4" inlet and outlets in standard flat gasket design for Code F filter cartridges, and 222 O-ring design for Code 0 filter cartridges. Heads are available with double cap plug design and viton O-rings. Durable housings are made from all polypropylene materials (except for O-rings) Housings contain no fillers, colorants, plasticizers, or lubricants Available in flat gasket design for Code F filter cartridges, and 222 O-ring design for Code 0 filter cartridges Housings are autoclavable and hydrogen peroxide compatible Supplied with 3/4" NPT inlet and outlets
FILTER HOUSING SPECIFICATIONS Dimensions 10" Cartridge Diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2" (13.2 cm) Length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.2" (31 cm)
20" Cartridge
5.2" (13.2 cm) 22.4" (57 cm)
10" Cartridge
20" Cartridge
6 gpm (22.7 lpm)
Maximum (Code 0 cartridge). . . . . . . . . . . . . . 4 gpm (15 lpm) Natural polypropylene cap and housing with standard Viton E-60 o-rings
Operating Parameters
Maximum Operating Pressure . . . . . . . . . . . . Maximum Operating Temperature . . . . . . . . . Sterilization/Sanitization Autoclavable . . . . . . . . . . . . . . . . . . . . . Hydrogen Peroxide . . . . . . . . . . . . . . . . 100 psi (6.9 bar) 100F (38C) 25 min 121127C (252260F) 7.5% compatibility; static soak up to 24 hr at ambient temperature
Weight
10" housing . . . . . . . . . . . . . . . . . . . . . . . . . 3 lb (1.4 kg) 12" housing . . . . . . . . . . . . . . . . . . . . . . . . . 3.5 lb (1.6 kg) 20" housing . . . . . . . . . . . . . . . . . . . . . . . . . 4.25 lb (1.9 kg)
ORDERING INFORMATION Catalog Number and Description ZHA X D XX 01 Natural polypropylene filter housing Cartridge Code: F = Code F, 0 = Code 0 Cartridge Configuration: D = Double cap plug Length: 10 = 10, 12 = 12, 20 = 20 Number of Tubes: 01 = 1 tube
To figure your order number, replace the X with one of the numbered/lettered options below it.
28
A Total Solution from One Supplier: The USFilter Difference USFIlter understands how important it is for your water treatment equipment to operate reliably and economically. Thats why we offer a wide range of high-quality, economical aftermarket products and services worldwide to meet your needs. We help you stay ahead with our full selection of products and services. From replacement parts to upgrading an existing system, we provide total solutions to help you manage your most challenging projects.
OUR AFTERMARKET SERVICES AND PRODUCTS SERVICE DEIONIZATION (SDI) WATER ANALYSIS/RESIN ANALYSIS MAINTENANCE CONTRACTS RESIN REGENERATION MOBILE TREATMENT SYSTEMS MEMBRANE CLEANING WASTEWATER SERVICES COMPLETE WATER SYSTEMS LABORATORY SYSTEMS ION EXCHANGE RESIN REPLACEMENT PARTS FILTER CARTRIDGES FILTRATION MEDIA RO MEMBRANES
Your USFilter sales representative is your single contact for any components you require for your facility. In addition, that same representative can arrange to have maintenance technicians dispatched from one of our many local branches, should your system ever require service.
USFilter is ready to serve you quickly and efficiently with over 70 service centers and 5 distribution and regeneration plants nationwide.
In the Continental United States 800.466.7873 Customer Service 24-hour 800.875.7873 ext. 5000 Technical Support 10 Technology Drive Lowell, MA 01851 In Canada USFilter Canada East (Toronto) 905.890.2803 Customer Service 24-hour USFilter Canada West (Calgary) 403.250.2650 Customer Service 24-hour
In accordance with USFilter policy for continual product development and improvement, we reserve the right to change the product specification within this literature at any time, without notice. USFilter, CDI, are registered trademarks of United States Filter Corporation or an affiliated company. Printed on recylced paper in the U.S.A. 2/01 Literature No.: LO-AF-CA-0101