Limit switches
For mechanical handling applications, type XC1-AC

XC1-AC with slow break contacts

With head for linear movement (plunger) operators

Page 32603/2

XC1-AC with snap action time delay contact

With head for linear movement (plunger) operators

Page 32603/4

2602 Ver4.00-EN.fm/2

Schneider Electric

General characteristics

Limit switches
For mechanical handling applications, type XC1-AC

Environment
Conforming to standards Product certifications IEC 947-5-1, IEC 337-1, EN 60 947-5-1,VDE 0660-200, CSA C22-2 n 14 Special version : CSA 600 V (ac) HD

Protective treatment Ambient air temperature Operating position Vibration resistance Shock resistance Electric shock protection

Standard version : TC. Special version : TH Operation : - 25+ 70 C Storage : - 40+ 70 C All positions 9 gn (10500 Hz) conforming to IEC 68-2-6 95 gn (11 ms) conforming to IEC 68-2-27 Class I conforming to IEC 536 and NF C 20-030

Degree of protection Mechanical durability Cable entry

IP 65 conforming to IEC 529 and NF C 20-010 10 million operating cycles 3 tapped entries for 13 mm cable gland

Contact block characteristics


Conventional thermal current Rated insulation voltage 10 A Slow break contact blocks : a 500 V and c 600 V conforming to IEC 947-5-1, NF C 20-040 a and c 600 V conforming to CSA C22-2 n 14 Snap action contact blocks : a 500 V

Resistance across terminals Minimum operating force Terminal referencing Short-circuit protection Electrical durability

8 m
XC1-AC1p1 : 33 N, XC1-AC1p6 : 23 N, XC1-AC1p7 : 29 N Conforming to CENELEC EN 50013 10 A cartridge fuse type gG (gl) Conforming to IEC 947-5-1 Appendix C. Utilisation categories AC-15 and DC-13. Operating rate : 3600 operating cycles/hour. Load factor : 0.5 Slow break contact blocks Snap action contact blocks Power broken in VA 48 450 170 110 900 350 230 1900 430 Voltage V For 1 million operating cycles For 3 million operating cycles For 10 million operating cycles Power broken in W 48 100 35 110 100 40 230 95 33 Voltage V For 1 million operating cycles For 3 million operating cycles For 10 million operating cycles 48 110 110 35 110 95 95 30 230 80 80 20 48 400 4000 120 110 1200 700 180 230 1300 750 200

a.c. supply a (50/60 Hz) o inductive circuit

Power broken in VA Voltage V For 1 million operating cycles For 3 million operating cycles

d.c. supply c o inductive circuit

Power broken in W Voltage V For 1 million operating cycles For 3 million operating cycles