Você está na página 1de 5

FORMATTING THE HARD DISK IN THE GPB Use hyper terminal - RS 232 from PC to Node B, port A of GPB Press

Enter and you should see $ appearing, if not check the cable connections!

0.

$ ifconfig

(To check current ip address of Node B)

interface: le0 inet: 10.192.17.185 netmask: 255.255.255.248 broadcast: 10.192.17.191 1.

$ reload --

(To put GPB in back up mode, Note IP address, subnetmast all will be lost)

OSE Delta PowerPC krn-750/R2.1.2 Welcome to OSE Shell OSE4.3. Stop due to remain in backup set

2.

$ vols

//should see /d and /c2 volumes (/c2 indicates that its the backup) free frw device unit 0K 100% FR0K 100% FRW 245M 84% FRW idedd 0 <4-599999> 673M 86% FRW idedd 0 <600000-2199999>

volume total used / 0K 0K 100% /null 0K 0K 100% /d 292M 47M 16% /c2 781M 107M 14%

3.

$ formathd /d

(Scratch hard disk - sector d)

All data on volume will be destroyed. Continue? y/n (n): 4.

$ formathd /c2

(Scratch hard disk - sector c2)

All data on volume will be destroyed. Continue? y/n (n): 5.

$ vols

// should see /d and /c2 are now empty (see under Used column)

volume total used free frw device unit / 0K 0K 100% 0K 100% FR/null 0K 0K 100% 0K 100% FRW /d 292M 0M 0% 292M 100% FRW idedd 0 <4-599999> /c2 781M 0M 0% 780M 100% FRW idedd 0 <600000-2199999>

SETTING UP IP ADDRESS & PASSWORD

1.

$ reload --

(need to execute this reload -- again or ip address definition will not execute)

OSE Delta PowerPC krn-750/R2.1.2 Welcome to OSE Shell OSE4.3 Stop due to remain in backup set 2.

$ ifconfig (Should not see previous IP setting as all is lost when in backup mode - need to define again )

Interface configuration never made for le0 IP address must be set via command: Usage: ifconfig <ifname> [<address>] [netmask <mask>] [broadcast <address>] 3. $

ifconfig le0 10.192.17.185 netmask 255.255.255.248 broadcast 10.192.17.191

4.

$ ifconfig // to see if ip address is correct

interface: le0 inet: 10.192.17.185 netmask: 255.255.255.248 broadcast: 10.192.17.191 5.

$ passwd Press Enter (allow us to use telnet later)


(As you type rbs you will not see it on the screen)

Enter new password: Re-enter new password: 6. $ reload

--

OSE Delta PowerPC krn-750/R2.1.2 Welcome to OSE Shell OSE4.3 Stop due to remain in backup set 7. $ifconfig // to see if ip address is correct

interface: le0 inet: 10.192.17.185 netmask: 255.255.255.248 broadcast: 10.192.17.191 8. Connect notebook to ethernet (Port D in GPB)- set ip address in notebook to 10.192.17.186 netmask 255.255.255.248 (My network places/properties/local area connection/properties/TCP/IP/properties/Use the following IP address. Make sure the status of connection ie disable and then enable) Make sure you can ping the node:

ping 10.192.17.185 (Start/run/cmd)

LOADING BASIC PACKAGE

Make sure notebook is connected to RBS Ethernet port D (old) or B (new)


1. Run wsftple, and complete the session properties Profile name: rbs Hostname/address: 10.192.17.185 Host type: Auto detect User Id: rbs Password: rbs 2. On remote site, change to / directory and enter Now highlight d and c2 folders on local system from the basic package - for example.. C:\3G Fauzi P3 for Training\rbs\P4\Basic cv\CXP9010811%2_R7E\hard_disc Transfer both (c2 and d ) to RBS node by pressing button. This should take about 20 minutes 3. Go to hyperterminal and enter to see $ 4. $ reload (To put c2 to c - active mode) OSE Delta PowerPC krn-750/R2.1.2 Welcome to OSE Shell OSE4.3. $ Start of @(#)cr@@/main/342 CXC1321445 R3B01 2001-05-29 gpb_backup mp750 Plug-in Unit Product Name: GPB Plug-in Unit Product No: ROJ1192106/2 Plug-in Unit Product rev: R4D Plug-in Unit Product Date: 01W34 Plug-in Unit Product Serial: A101510318 Ethernet MAC_address 0: 0x008037129282 Ethernet MAC_address 1: 0x008037129283 Rbs_basic_cv BoardMgr: Starting Configuration Version: rbs_basic_cv .Ready 5. $

vols

(To check that the GPB is in active mode ie c2 now becomes c)

volume / /null /d /c /j 6. $

total used free frw device unit 0K 0K 100% 0K 100% FR0K 0K 100% 0K 100% FRW 292M 30M 10% 262M 90% FRW idedd 0 <4-599999> 781M 85M 11% 695M 89% FRW mirrordd 0 <600000-2199999> 781M 85M 11% 695M 89% FRW /c 0 <600000-2199999>

pglist //lists 37 loadmodules

Program Information: Handle : 1 Status : run Resident : True Name : CXC1320785_R10M%1 Argv : to .. Handle : 37 Status : run Resident : True

Name : CXC1321395%2_R2A01 Argv : 7. $

cv cu

//lists shows 'rbs_basic_cv' (rbs_basic_cv from factory)

Startable: rbs_basic_cv Loaded: rbs_basic_cv Rollback status: Rollback is on Rollback init timer: 30 Rollback init counter: 5 Rollback counter: 3 cv cu (configuration version current) LOADING INITIAL CV 1. Start up EM by opening IE with <http://10.192.17.185/em/index_stubbed.html> 2. Click Configuration>Cabinet Equipment, you will see configuration node production centre, click next 3. Configuration cabinet equipment - page 1(6), click on wizard and click next 4. Configuration cabinet equipment - page 3(6), complete the configuration data as per hardware in Node B especially the ETM-1 type to E1, click next. 5. Complete the ip configuration data ie. IP = 10.192.17.185 and subnet mask 255.255.255.248, click next 6. Check your configuration settings 5 (5), if ok, click Finish 7. Now Node B will be loaded with the current configuration that you defined and will auto re-start with cv = INITIAL _CV - EM will have to be shut down and restarted as well. Result: Configuration Completed Successfully Cabinet Configuration ------------------The RBS will now restart in order to activate equipment configuration. The connection to the RBS will be lost. Please close the Element Manager and the browser. The RBS will have the following IP configuration after the restart: IP Address: 10.192.17.185 Subnetmask: 255.255.255.248

INITIAL_cv

OAM Access Wizard 8. Start EM - >Configuration Tab> O&M access> next >

OAM_CV

click use configuration file, file path ie C:\3G Fauzi P3 for Training\script\rbs 3206 pdjtnegra\OAM PDJTNEGRA Auto no wizard. Next - you will see O&M Configuration data Finish, (you will loose connection) and you will see configuration completed successfully, click ok

Site Configuration Wizard


9. Run EM ->Configuration>Site Equipment> click Next click use configuration file file path ie C:\3G Fauzi P3 for Training\script\SE PDJTNEGRA click Wizard check result is successful, click next

SITE EQUIPMENT CV

10. Complete the data logical name, click next Alex server address, click next Sector data configuration, click next NTP server and time date etc, click next Antenna branch configuration - New value freqBandHiEdge = 10750 and freqBandLoEdge = 10650 Antenna cable configuration, click next Initiate sector, click next Rbs Local Cell Configuration, click next Site Equipment Configuration summary, click next Finish, wait for it to create site configuration, okay.

***********************************************************DONE***************************************************************