Você está na página 1de 18

Q.

1)

eaves over required windows not < _____. minimum over from the side & rear property lines

A. 300 MM B. 600 MM C. 1000MM D. 750MM (Correct Answer) Unanswered Q.2) A. B. C. D. Unanswered sum of areas of openings must not exceed _____ % of sum of areas of walls 50 (Correct Answer) 20 40 60

Q.3)

Distance of Exits w/o sprinkler ____m from exterior exit door, w/ sprinkler will be ____m A. 45, 50 B. 30, 60 C. 45, 60 (Correct Answer) Unanswered

Q.4)

Width and Height of doors will be not < _____mm in width, not < ______m in height, opening will be 90 degrees and exit width not < 700mm 900,2.1 800, 2.0 900, 2.0 (Correct Answer)

A. B. C. Unanswered

Q.5)

If arcaded bldg, no chaflan reqtd notwithstanding the width of public street, <________m

A. 12 (Correct Answer) B. 13 C. 14 D. 15 Unanswered Q.6)

nonstructural facing brick, concrete, tile, metal, etc. attached at the backing or structural components for the purpose of ornamentation brick face stone veneer (Correct Answer)

A. B. C. D. Unanswered

Q.7)

spacing of rows of seats from back to back not < ______mm (standard seating) A. 840 (Correct Answer) B. 850 C. 860 Unanswered

Q.8)

new construction w/c increases the height or area of an existing bldg./structures. addition (Correct Answer) renovation revision alteration

A. B. C. D. Unanswered

Q.9)

inner courts shall be connected to a street or yard, or by a passageway at least how many meters A. 1.0 B. 1.1 C. 1.2 (Correct Answer) D. 1.3 E. 2 Unanswered

Q.10) A. B. C. Unanswered

if only 2 exits required, shall be placed distance apart not < ____ of the perimeter area. 1/3 1/4 1/5 (Correct Answer)

Q.11)

Foundations not < _______ mm below the grade, may encroach ______mm into public sidewalk areas A. 600, 500 (Correct Answer) B. 600, 400 C. 500, 300 D. 600, 600 Unanswered

Q.12)

Footings must be at least _______ m below grade along national roads, may project not >______mm beyond Property line. 2.4, 400 2.5, 300 2.3, 400 2.4, 300 (Correct Answer)

A. B. C. D. Unanswered

Q.13)

a permanent roofed structure above a door attached to and supported by the building and projecting over a wall or sidewalk A. balconies B. awnings C. canopies (Correct Answer) Unanswered

Q.14)

Projection & Clearance of canopies outermost edge of the marquee and the curb line shall be not < _____mmvertical clearance bet pavem undersurface of a marquee shall not < 3.00m 400 200 300 (Correct Answer) 500

A. B. C. D. Unanswered

Q.15)

work done on any damaged/deteriorated portion of bldg. A. alteration B. renovation C. repair (Correct Answer) Unanswered

Q.16)

window openings for room must have at least _____% of the floor area with a minimum area of _____ sq.m. 20, 1 10, 2 10,1 (Correct Answer) 20,2

A. B. C. D. Unanswered

Q.17)

window openings for baths and toilets must have at least ____ of the floor area with a minimum area of _____ sq.mm A. 1/20 , 250 B. 1/10, 240 C. 1/20, 240 D. 1/10, 240 (Correct Answer) Unanswered

Q.18)

WHICH IS NOT INCLUDED IN THE EXCEPTION OF BUILDING PERMIT? PRIVATE BUILDING PUBLIC BUILDING (Correct Answer) INSTITUTIONAL BUILDING

A. B. C. Unanswered

Q.19)

WHICH ARE NOT INCLUDED FOR THE REQUIREMENTS FOR BUILDING PERMIT

A. The use or occupancy of proposed work B. A description of work to be covered by the permit C. Description and ownership of the lot TCT D. Estimated cost of proposed work E. TAX DOCUMENTS (Correct Answer) Unanswered Q.20) WHAT TYPE OF CONSTRUCTION IS FOR WOOD CONSTRUCTION WITH FIRE RESISTANT MATERIALS 1 HR FIRE RESISTIVE RATING TYPE II (Correct Answer) TYPE III TYPE IV TYPE I

A. B. C. D. Unanswered

Q.21)

WHAT TYPE OF CONSTRUCTION IS FOR WOOD CONSTRUCTION A. TYPE II B. TYPE III C. TYPE I (Correct Answer) D. TYPE IV Unanswered

Q.22)

WHAT TYPE OF CONSTRUCTION IS FOR WOOD AND MASONRY CONSTRUCTION WITH FIRE RESISTANT MATERIALS 1 HR FIRE RESISTIVE RAT TYPE II TYPE IV TYPE III (Correct Answer) TYPE I

A. B. C. D. Unanswered

Q.23)

WHAT TYPE OF CONSTRUCTION IS FOR STEEL, IRON CONCRETE CONSTRUCTION WITH FIRE RESISTANT MATERIALS 1 HR FIRE RESISTIVE RAT A. TYPE V B. TYPE II C. TYPE IV (Correct Answer) D. TYPE III Unanswered

Q.24) A. B. C. D. Unanswered

Vertical Clearance of awning (undermost surface of the awning or GL) not < ______m 3 2.7 2.4 (Correct Answer) 2.8

Q.25)

Ventilation or vent shafts horizontal cross-sectional area not <_____ sq.m per meter height of shaft A. 0.15 B. 0.10 (Correct Answer) C. 0.20 D. 0.12 Unanswered

Q.26)

this is where all on site work done office construction (Correct Answer) plants

A. B. C. Unanswered

Q.27)

the width of a stair way if the occupant load of more than 50 shall not be < ____ m A. 1.2 B. 1.1 C. 1 (Correct Answer) D. 1.5 Unanswered

Q.28)

the width of a stair way if the occupant load of less than 50 shall not be < ____ m 0.90 (Correct Answer) 1 0.80

A. B. C. Unanswered

Q.29)

the slope of an exit passage way will have a maximum slope of A. 1/8 (Correct Answer) B. 1/10 C. 1/15 Unanswered

Q.30)

the slope of an exit courts will have a maximum slope of 1/10 (Correct Answer) 1/8 1/12

A. B. C. Unanswered

Q.31)

the size of room for kitchen must be at least

A. 1.5X2m (Correct Answer) B. 1.5x3m C. 2x3m D. 1.5x2.1m Unanswered Q.32) the size of room for human habitation must be at least an area of _____ sq.m. and ______M minimum distance 6,2 (Correct Answer) 7,3 6,3 7,2

A. B. C. D. Unanswered

Q.33)

the size of bathrooms or toilets must be at least an area of _____ sq.m. and ______M minimum distance A. 1.2, 1.0 B. 1.5, 0.9 C. 1.2, 0.9 (Correct Answer) Unanswered

Q.34)

the RATING IN which a material can withstand fire FIRE RESPECTIVE RATING FIRE RESISTIVE RATING (Correct Answer) FIRE PROTECTIVE RATING

A. B. C. Unanswered

Q.35)

the number of exits for Mezzanin with 185 sq.m area or more than 18m in dimension will be exits A. 1 B. 2 (Correct Answer) C. 3 Unanswered

Q.36) A. B. C. Unanswered

the number of exits for Above 1 storey with 10 occupant ____ exits 1 2 (Correct Answer) 3

st

Q.37)

the minimum row space with backrest will be A. B. 700 750 (Correct Answer)

C. 850 Unanswered Q.38) the maximum rise and run of the stairs will be 200, 200 200, 250 (Correct Answer) 200, 300 250, 250

A. B. C. D. Unanswered

Q.39)

the headroom clearance for stair will be A. 2.1m B. 2.0m (Correct Answer) C. 2.5m Unanswered

Q.40)

THE GENERAL PROVISION OF PD 1096 OR THE NATIONAL BUILDING CODE OF THE PHILIPPINES ARE! Safe construction Adequate environmental safeguards Maintain building in safe, sanitary and good working conditions ALL OF THE ABOVE (Correct Answer)

A. B. C. D. Unanswered

Q.41)

THE ENFORCEMENT OF PD1096 ON THEIR RESPECTIVE JURISDICTION IS THE A. MAYOR B. ARCHITECT C. BUILDING OFFICIAL (Correct Answer) D. CITY ENGINEER Unanswered

Q.42) A. B. C. Unanswered

the door that will be required if the exit door shall swing to exit travel in hazardous areas w/ 50 or more occupant load swing (Correct Answer) panel leaf

Q.43)

the distance between 2 landings in stairs will be a maximum of A. 3.0m B. 3.6m (Correct Answer) C. 3.5m Unanswered

Q.44)

THE BUILDING PERMIT WILL BE NULL OR VOID IF THE CONSTRUCTION DIDN'T COMMENCE D THE WORK IN A PERIOD OF 6 MONTHS 12 MONTHS (Correct Answer) 2 YEARS 3 MONTHS

A. B. C. D. Unanswered

Q.45)

THE BUILDING PERMIT WILL BE NULL OR VOID IF THE CONSTRUCTION HAS BEEN ABANDONED FOR HOW MANY DAYS A. 30 B. 60 C. 120 (Correct Answer) D. 80 Unanswered

Q.46)

systematic dismantling of a bldg in whole or part. reinstallation demolition (Correct Answer) dismantle

A. B. C. Unanswered

Q.47)

stair with a straight run, the landing will be a maximum of _______ m vertical distance A. 1.5 B. 1.2 (Correct Answer) C. 1.4 Unanswered

Q.48)

spacing of rows of seats from back to back : rows of 46 seats or more (continental) 450mm 500mm 520mm 550mm (Correct Answer)

A. B. C. D. Unanswered

Q.49)

spacing of rows of seats from back to back : rows of 45 seats or less (continental) A. 450mm B. 500mm C. 520mm (Correct Answer) D. 550mm Unanswered

Q.50)

spacing of rows of seats from back to back : rows of 35 seats or less (continental) 450mm 500mm (Correct Answer) 520mm 500mm

A. B. C. D. Unanswered

Q.51)

spacing of rows of seats from back to back : rows of 18 seats (continental) A. 500mm B. 450mm (Correct Answer) C. 520mm D. 550mm Unanswered

Q.52)

side aisle width will be a minimum of 1.0m 1.1m (Correct Answer) 1.2m 1.3m

A. B. C. D. Unanswered

Q.53)

Reviewing Stands, Grandstands, and Bleachers the minimum row spacing of seats without backrest in open air stand A. 600 (Correct Answer) B. 650 C. 700 Unanswered

Q.54)

Public Street or alley <______m in width shall be truncated at the corner Chaflan 3.4 3.6 (Correct Answer) 3.5 3.7

A. B. C. D. Unanswered

Q.55)

private stairways that serve <10 occupants will be a minimum of _____m A. 0.60 B. 0.80 C. 0.75 (Correct Answer) D. 0.70 Unanswered

Q.56)

PD 1096 WILL BE ENFORCED BY THE SECRETARY OF UAP PRC MUNICIPALITY PUBLIC WORKS (Correct Answer)

A. B. C. D. Unanswered

Q.57)

minimum aisle width if serving only two side A. 1m (Correct Answer) B. 1.2m C. 1.5m D. 0.90m Unanswered

Q.58)

minimum aisle width if serving only one side 800 (Correct Answer) 900 700

A. B. C. Unanswered

Q.59)

min height of mezzanine floor in meters A. 1.80 (Correct Answer) B. 2.0 C. 1.75 D. 1.85 Unanswered

Q.60)

means "installation of components of a building/structure" secure erection (Correct Answer) site work

A. B. C. Unanswered

Q.61)

Maintenance and Removal of Protective Devices

protective fence or canopy shall be removed ____days after protection no longer required.

A. 30 (Correct Answer) B. 15 C. 20 Unanswered Q.62) located partly in one (1) fire zone and partly in another

A. B. C. D. Unanswered

HIGH RESTRICTIVE FIRE ZONES (Correct Answer) MODERATE RESTRICTIVE FIRE ZONES HIGH RESTRICTIVE FIRE HAZARDS MODERATE RESTRICTIVE FIRE HAZARDS

Q.63)

in winding stairsways, the narrower side of the tread will be __________ A. 150-250mm B. 200-300 mm C. 150-300mm (Correct Answer) Unanswered

Q.64)

IN QUALIFICATION FOR BEING AN BUILDING OFFICIAL, YOU MUST HAVE A DIVERSIFIED WORKING EXPERIENCE OF AN ARCHITECT OR ENGI HOW MANY YEARS? 6 4 5 (Correct Answer) 7

A. B. C. D. Unanswered

Q.65)

IN QUALIFICATION FOR BEING AN BUILDING OFFICIAL, YOU MUST BE A REGISTERED ? A. ARCHITECT B. ENGINEER C. URBAN PLANNER D. LANDSCAPE ARCHITECT E. A AND B (Correct Answer) Unanswered

Q.66)

IN QUALIFICATION FOR BEING AN BUILDING OFFICIAL, YOU MUST BE A MEMBER OF A ACCREDITED ORGANIZATION OF NOT LESS THAN HO YEARS 2 YEARS (Correct Answer) 1.5 YEARS 3 YEARS 5 YEARS

A. B. C. D. Unanswered

Q.67)

HOW MANY SETS OF PLANS AND SPECIFICATION ARE NEEDED FOR THE REQUIREMENTS OF BUILDING PERMIT? A. B. C. D. 5 (Correct Answer) 4 6 7

Unanswered Q.68) HOW MANY DAYS IT WILL TAKE FOR THE ISSUANCE OF BUILDING PERMIT? 12 DAYS UPON PAYMENT 15 DAYS UPON PAYMENT (Correct Answer) 14 DAYS UPON PAYMENT 30 DAYS UPON PAYMENT

A. B. C. D. Unanswered

Q.69)

handrails in stairs will be _________ MM A. 800-900 (Correct Answer) B. 700-900 C. 900-1200 Unanswered

Q.70)

Groups H, I occupancies w/o seats, line of travel to exit door by an aisle is not > ______ m 45 (Correct Answer) 30 60

A. B. C. Unanswered

Q.71)

For Protective Nets/Screen the G.I wire gauge must be ________mm mesh _____ net; canvas A. 16.38 MM / nylon (Correct Answer) B. 16.37 mm/ steel C. 16.39 mm/ nylon D. 16.38mm/ steel Unanswered

Q.72)

for Protection of Pedestrians during Construction or Demolition Fences must be not < _____mabove grade 2.3 2.2 2.4 (Correct Answer) 2.5

A. B. C. D. Unanswered

Q.73)

for Protection of Pedestrians during Construction or Demolition Canopies must _______m above the railway, live load 600 kg per sq.m. A. 2.5 B. 2.6 C. 2.4 (Correct Answer) D. 2.3 Unanswered

Q.74)

for Protection of Pedestrians during Construction or Demolition the Temporary walkway will be at least _____m wide (during constructio 1.2 (Correct Answer) 1.3 1.4 1.5

A. B. C. D. Unanswered

Q.75)

for Protection of Pedestrians during Construction or Demolition the Capable of supporting a uniform live load of ____ kg per sq.m for tem way A. 600 B. 650 (Correct Answer) C. 620 D. 630 Unanswered

Q.76)

for Pedestrian Protection Railings in street side of the sidewalk must be at least_____m in height 1 (Correct Answer) 2 1.2 0.90

A. B. C. D. Unanswered

Q.77)

for exit sign illumination the minimum lux equivalent will be A. 10.7 (Correct Answer) B. 10.6 C. 10.8 Unanswered

Q.78)

for circular stair that will be used as an exit the minimum width of run will be < ______ mm 200 250 (Correct Answer) 300

A. B. C. Unanswered

Q.79)

for attics the Access will be not < _____mm sq. or in diameter, min clear headroom of ____mm A. B. C. D. 600, 800 (Correct Answer) 800, 600 600, 700 700, 800

Unanswered Q.80) for 599-999 occupants how many exit needed 1 2 3 (Correct Answer)

A. B. C. Unanswered

Q.81)

FIRE PUMPS WILL BE CONNECTED TO STREET MAIN W/ NOT LESS THAN A. 120 MM DIAMETER B. 150 MM DIAMETER C. 100 MM DIAMETER (Correct Answer) Unanswered

Q.82)

FIRE PUMPS CAPACITY WILL BE NOTE LESS THAN 1000 LITERES PER MINUTE (Correct Answer) 2000 LITERES PER MINUTE 3000 LITERES PER MINUTE

A. B. C. Unanswered

Q.83)

FIRE PUMP PRESSURE WILL BE NOT LESS THAN A. 1.5 KG/ SQ CM B. 2 KG/SQ.CM (Correct Answer) C. 1 KG/SQ.CM Unanswered

Q.84)

FIRE EXTINGUISHING SYSTEM WILL BE PROVIDED FOR EVERY STOREY , BASEMENT OR CELLAR WHICH WILL BE USED AS OFFICE HABITATION (Correct Answer) STORAGE

A. B. C. Unanswered

Q.85)

FIRE EXTINGUISHING SYSTEM WILL BE PROVIDED FOR EVERY STOREY , BASEMENT OR CELLAR WITH AN AREA OF A. 300 SQ.M. B. 250 SQ.M. C. 200 SQ.M. (Correct Answer) D. 350 SQ.M. Unanswered

Q.86)

FIRE EXTINGUISHING SYSTEM WILL BE PROVIDED FOR EVERY STOREY , BASEMENT OR CELLAR WHICH WILL BE USED AS HABITATION WITH OCCUPANT LOAD OF MORE THAN

A. B. C. D. Unanswered

30 40 20 (Correct Answer) 50

Q.87) 1.

Excavation made on public property - restored immediately to its former conditions w/in _____ hrs A. 48 (Correct Answer) B. 120 C. 12 D. 36 Unanswered

Q.88)

Door leaf width will be a maximum of ______ 2.5 1.2 (Correct Answer) 1.5 1

A. B. C. D. Unanswered

Q.89)

Distance bet sprinklers will be max of _____ center to center A. 1.20 B. 1.80 (Correct Answer) C. 1.30 D. 1.40 Unanswered

Q.90)

Construction for canopies for incombustible materials not < ____ hrs fire-resistive 1 3 2 (Correct Answer) 4

A. B. C. D. Unanswered

Q.91)

ceiling heights for habitable rooms without artificial ventilation from finish floor to ceiling is A. 2.70 (Correct Answer) B. 2.40 C. 2.10 Unanswered

Q.92)

ceiling heights for habitable rooms with artificial ventilation from finish floor to ceiling 1st storey and onwards respectively (1st storey, 2n

storey onwards) in meters A. B. C. Unanswered 2.7, 2.5, 2.0 2.7, 2.4, 2.0 2.7, 2.4,2.1 (Correct Answer)

Q.93)

areas within which only certain types of buildings are permitted to be constructed based on their use or occupancy, type of construction A. FIRE HAZARDS B. FIRE ZONES (Correct Answer) C. FIRE AREAS Unanswered

Q.94)

air space requirements for workshop, factories, and offices 3.00 cu.m w/ 1.00 sq.m of floor area per person 14.00 cu.m of air space per person 12.00 cu.m of air space per person (Correct Answer)

A. B. C. Unanswered

Q.95)

air space requirements for school rooms will be A. 3.00 cu.m w/ 1.00 sq.m of floor area per person (Correct Answer) B. 12.00 cu.m of air space per person C. 14.00 cu.m of air space per person Unanswered

Q.96)

Air Ducts ______ sq.m w/ at least dimension of 300mm 0.25 0.30 (Correct Answer) 0.35 0.40

A. B. C. D. Unanswered

Q.97) a.

a written authorization granted by the BO to an applicant allowing the applicant to proceed w/ the construction w/ specific project after plans, specs and other pertinent doc. A. no objection certificate B. notice to proceed C. building permit (Correct Answer) Unanswered Q.98) a movable shelter supported from an exterior wall of a bldg. w/c can be retracted, folded, collapsed against the face of a supporting bldg. A. canopies

B. C. Unanswered

balconies awnings (Correct Answer)

Q.99)

. Size & Dimensions of Courts min. horizontal dimension not < ________ A. 1.5 M B. 2.5 M C. 1.2 M D. 2.0 M (Correct Answer) Unanswered

Q.100) the clearance of Awning to curb line not <_____mm A. B. C. D. Unanswered 400 500 200 300 (Correct Answer)

Q.101) secondary bldg. located w/in the same premises the use of incidental to that main bldg. a. A. ancillary building (Correct Answer) B. extra building C. expanded structure Unanswered Q.102) a. physical change made to increase its value & improve its aesthetic quality. alteration renovation (Correct Answer) addition

A. B. C. Unanswered

Q.103) a. changes in materials, utilities, partitioning, etc but doesnt increase the overall area thereof. A. addition B. renovation C. alteration (Correct Answer) Unanswered Q.104) a. change in use or occupancy A. alteration

B. C. Unanswered

addition conversion (Correct Answer)

Q.105) 1.

Area Separation enclosed attic space of combustible construction shall be divided into horizontal area max of _____ sq.m. area, _____ for attic with Fire-extinguishing system.

A. B. C.

250, 750 (Correct Answer) 750, 250 300, 750