2008 Product Catalogue

A comprehensive range of Air Conditioning Systems from Mitsubishi Electric

the name Mitsubishi is synonymous with excellence


Known the world over, Mitsubishi is a trusted global leader associated with a variety of products and services. Founded in 1907, the company known today as Mitsubishi Electric, quickly rose to the forefront of the air conditioning industry a position we still enjoy today.

Unsurpassed air conditioning from Mitsubishi Electric


Air conditioning is an ideal way of controlling the air quality inside any building, large or small. Not only does it cool in the summer months but air conditioning can also heat, replacing traditional heating systems. More and more people today are experiencing the benefits of comfortable working, living and leisure environments made possible with air conditioning. As market leaders, we pride ourselves in providing high performance, competitive systems with low running costs.

Protecting the environment


Mitsubishi Electric boasts an explicit commitment to sustainable business practices such as energy and resource efficiency, minimising ecological impacts of our products and reducing greenhouse gas emissions. We are the only manufacturer in the industry recognised by Portfolio 21 as one of the top five companies in the world for our sustainable environmental policy. All of our factories are also ISO 14001 registered, the international standard that specifies a process for controlling and improving a company's environmental performance and with the advent of our Green Gateway Initiative, we strive to constantly promote best practice. The Forest Stewardship Council (FSC) is an international network promoting responsible management of the world's forest. The paper this catalogue is printed on supports the development of responsible forest management worldwide. The wood comes from FSC certified, well managed forests, company controlled sources and/or recycled material.

Bigger, better and easier to use: the new 2008 Mitsubishi Electric Air Conditioning Product Catalogue
This revised catalogue offers you more information than ever before. The first thing youll notice is that the 2008 catalogue is bigger than before. Thats because the Mitsubishi Electric air conditioning range contains many new models, plus a fully comprehensive selection of control options to choose from. In addition to increasing the range, weve also tried to help you find what you need more quickly and efficiently. We hope you will find it an interesting and informative read. If there is anything not covered in the catalogue and you want to know more, simply contact your Mitsubishi Electric supplier who will be delighted to help you. Alternatively, you can log onto our website at www.mitsubishielectric.co.uk/aircon for further information.

Contents
Page 13-52 Page 53-116 Page 117-197 Page 199-217 Page 219-254

Page 1

M Series / Mr Slim
Split-System Air Conditioning

Mitsubishi Electric Split-Systems


M Series and Mr Slim
For the last couple of years Mitsubishi Electrics M Series and Mr Slim range of split-systems have gradually moved closer together, in terms of features and benefits, capacity and now most importantly in terms of control. While both ranges maintain their individual brand identity, all of our models have benefited from massive investment by Mitsubishi Electric, the overall result being a vastly improved and more flexible collection of split-systems.
One of the most important features of the inverter range is the adoption of a new version of A Control, allowing the standardisation of the M Series and Mr Slim ranges, as well as strengthening the remote controller functionality. As a result of this it is now also possible to connect Mr Slim indoor units to MXZ Multi-Split outdoor units, allowing for complete design flexibility. The Mr Slim Standard Inverter models have further increased the range, offering a lower cost option, whilst still incorporating Mitsubishi Electrics energy saving inverter technology. Also new to the Split-Systems range are the new high COP, MSZ-FD M Series models, our most efficient wall mounted units to date. A Control is Mitsubishi Electrics control mechanism for providing standard remote controller functions alongside system diagnostics, fault code monitoring and the ability to interface with the MELANS (Mitsubishi Electric Air Conditioning Network Solution) equipment such as the G50 Centralised Controller, TG2000, Modbus, Trend, LonWorks & BACnet etc. A Control has now been further improved by Mitsubishi Electric, providing increased flexibility alongside greater functionality.

Page 4

Energy Saving:
Reduced power consumption increased efficiency
The entire R410A M Series and Mr Slim ranges are available as an inverter option
Inverter technology saves energy for two main reasons:
1. The compressor varies its speed to match the cooling or heating load and therefore consumes only the power necessary to match the exact requirement of the room. 2. When an inverter driven air conditioner is operating at partial load, the energy efficiency of the system is significantly higher than at full load. In a typical application, partial load conditions prevail for more than 90% of operation time. A fixed speed system can only operate at 100% capacity and cannot match the annual efficiencies of an inverter system.

The adoption of this technology as standard by Mitsubishi Electric, shows our commitment to both increasing your savings as well as protecting the global environment.

Page 5

Energy Saving
Reduced power consumption increased efficiency

Technology

Application of new technologies in Mitsubishi Electric inver ter systems significantly enhance the generic benefits of inverter driven systems.

Reluctance DC Rotary Compressors


The centralised winding DC motor uses less copper wiring than a conventional version and features a new high density, centralised winding method that raises motor winding efficiency to 96%. Units incorporating this motor also benefit from a low starting current as well as a stable set point.

Highly Efficient Scroll Compressors


The scroll compressor is equipped with a Frame Compliance Mechanism that allows movement in the axial direction of the frame supporting the moving scroll. This construction realises up to a 27% improvement in compressor efficiency by reducing both leakage and friction losses.

DC Fan Motor
A high-efficiency DC motor drives the fan of the outdoor units. It offers up to 60% greater efficiency than an equivalent AC motor.

Simple Par tial Switching Method PAM Control


Compared to the conventional active filter method, the simple partial method PAM (Pulse Amplitude Modulation) control found on the new models helps to reduce energy losses. When combined with the Vector-Wave Eco Inver ter, PAM control also allows for greater power and efficiency.

Normal Inverter vs. PAM


Supply Voltage Current Supply Voltage Current

Time

Time

PAM adjusts the form of the current wave so that it is close to that of the supply voltage wave. High harmonics are reduced and 98% of the electricity is utilised.

Page 6

Total Energy Conser vation


Vector-Wave Eco Inverter
This technology uses a specially designed microprocessor to produce the most efficient waveform in response to varying compressor motor rpm. By improving operating efficiency from low to high speeds, annual electricity costs are reduced.

Power Receiver and Twin LEV Control


Mitsubishi Electric has developed a power receiver and twin LEVs (linear expansion valves) that optimise the performance of the compressor. By ensuring optimum control in response to the operating waveform and outdoor temperature, this technology is tailored to the characteristics of the new refrigerant to enhance operating efficiency.

Page 7

Re-use of existing pipe work


Upgrading existing R22/R407c systems to efficient inver ter models*
1

In general the upgrading of existing R22 systems to modern efficient R410A systems has been a difficult or expensive option. This is because the existing pipe work would either have to be replaced, or cleaned with dedicated specialist equipment. These actions were necessar y as the chlorine residue from R22 system pipe work caused chemical reactions with the lubricating oils used in HFC compressors, the result being poor performance and system failure.

Mitsubishi Electrics

Replace Technology
The M Series Inverter*2 & Mr Slim Power Inver ter ranges incorporate Replace Technology to allow the upgrading of systems using existing pipe work without the need to apply any special cleaning machines. Sizes 25 to 71 utilise the Mitsubishi Electric patented Hard Alkyl Benzene (HAB) oil, a unique oil that is more tolerant of contamination. By combining this oil with developments in oil separator technology it is possible for this model to use existing pipe work without any special operations. Sizes 100 to 250 continue to use the more familiar Ester Oils that are sensitive to chemical contamination. To allow these models to utilise existing pipe work a unique Replace Filter containing activated charcoal has been included in the refrigerant circuit. During commissioning the system is operated in Replace Mode, this operation removing all the chlorine contamination from the existing pipe work allowing trouble free operation.

Replacement filter (Sectional photo)


Activated carbon (absorbs chlorine and other chemicals) Refrigerant Refrigerant

Inlet

Filter

Outlet

*1 Assuming existing pipework is suitable for R410A operational pressures *2 Not available on the MXZ-8A140VA Multi-Split outdoor unit or Classic Inverter (MSZ-HC)

Page 8

Reduces installation time & costs


Advantages
For tenants / owner
s s

Reduces installation time causing less disruption of business Saves on installation costs

For installer
s s s

Installation time is reduced significantly It is not necessary to purchase new piping for R410A refrigerant Time-consuming pipe cleaning is not necessary when employing Replace Technology

Page 9

Split-System Product Range Overview


Outdoor Units
0.9kW Cooling Capacity
M Series Inverter M Series Inverter (Multi-Split) M Series Inverter M Series Inverter Multi-Split M Series Inverter Multi-Split M Series Power Multi

MUZ-GC25VA

MUZ-GC35/FD25-35VA(H) SUZ-KA25/35VA MXZ-2A52VA

MUZ-GB50/GA60-71VA SUZ-KA50-71VA

MXZ-3A54VA MXZ-4A71VA

MXZ-4A80VA MXZ-5A100VA

MXZ-8A140VA

Indoor Units
Model / Size 22 (2.2kW)
Multi-Split only

25 (2.5kW)

35 (3.5kW)

50 (5.0kW)

60 (6.0kW)

71 (7.1kW)

MSZ-GA/GB/GC-VA MSZ-FD-VA PKA-RP-GAL/FAL(2) MFZ-KA-VA SEZ-KD-VA PEAD-RP-EA(2) PEA-RP-GA SLZ-KA-VA PLA-RP-BA(2) PCA-RP-GA(2) PCA-RP-HA PSA-RP-GA

Page 10

44kW Cooling Capacity


Mr Slim Mr Slim Mr Slim Standard Inverter Mr Slim Standard Inverter Mr Slim Power Inverter Mr Slim Power Inverter Mr Slim Power Inverter

PUH-P100YHA

PUH-P125-140YHA

PUHZ-P100VHA2

PUHZ-P125-140VHA2 PUHZ-P200/250YHA

PUHZ-RP35/50VHA3

PUHZ-RP60/71VHA3

PUHZ-RP100V/YHA3 PUHZ-RP125/140V/YHA2 PUHZ-RP200/250YHA2

100 (10.0kW)

125 (12.5kW)

140 (14.0kW)

200 (19.0kW)

250 (22.0kW)

400 (38.0kW)

500 (44.0kW)

Page 11

The adaptable Split-System range

Designed to fit anywhere


Available in a variety of options, our Split-System range fits in wherever its needed. Indoor units

can be four way blow cassettes, ducted, wall,

floor or ceiling mounted. Up to eight indoor units

can then be connected to a single outdoor unit

providing the ideal air conditioning solution.

Simple technology
at its best
Systems marked with the ECA logo have an energy label of A or B, are registered on the Energy Technology List and hence qualify for 100% first year enhanced capital allowances (whole system cost and reasonable cost of installation). For further information please go to www.eca.gov.uk

Nominal conditions cooling: indoor 27C DB, 19C WB; outdoor 35C DB, 24C WB. Nominal conditions heating: indoor 20C DB; outdoor 7C DB, 6C WB. UK Conditions: Summer; indoor 21C DB, 15C WB; outdoor 27C DB. Winter; indoor 21C DB; outdoor -1C WB.

Page 12

M Series
Room Air Conditioning

The M Series range


Perfect for small to medium sized applications
Designed to heat or cool small to medium sized applications, the M Series range provides a versatile, yet affordable air conditioning solution. Quick to install and also one of the quietest units on the market (as low as 20dBA*1 ), this newly designed, attractive range offers the perfect way to ensure a comfortable environment with the minimum of disruption. Surprisingly affordable, the efficiency of the M Series range presents substantial savings in heating mode, when compared with more conventional heating systems. Additional features such as Econo-Cool allow airflow to be precisely directed towards users, allowing set temperatures to be raised by 2C with no loss in comfort and a 20% gain in energy efficiency. Flexible enough to suit a range of applications, the M Series includes models that will run up to eight indoor units per outdoor unit. With vastly increased pipe length and height differences over its R407c predecessors, the M Series is extremely versatile, helping to make system application easier. This diagram shows how a typical multi-split system could be installed into a medium sized office for example.

Highly efficient
whilst ozone friendly too
The entire M Series range is now available using Inverter technology. By matching the compressor speed to the cooling or heating load of the room, up to a 30% reduction in power consumption can be achieved. Increasingly aware of the importance of protecting the environment, the M Series range uses the (ozone friendly) refrigerant with zero ODP (Ozone Depletion Potential) - R410A. Many models also make use of a new air filtering system containing the compound Catechin, which helps to improve air quality and prevent the spread of bacteria and viruses. M Series offers the end user some of the highest energy efficiency ratings available, alongside greater application flexibility. Lower running costs and increased comfor t for consumers are vir tually guaranteed and Mitsubishi Electric has made M Series the natural choice for todays small to medium sized application market.

*1 MSZ-FD25VA

Page 14

Designed to fit

anywhere

Clean, Comfor table Environment


Catechin Filter
Catechin is a bioflavonoid that is found in green tea. Bioflavonoids are a group of chemical substances present in many plants, that have both antiviral and antioxidant qualities. In addition to these benefits, Catechin also offers excellent deodorising characteristics; which is why Mitsubishi Electric uses this compound in its air conditioning filters to not only improve air quality, but to also prevent the spread of bacteria and viruses within a room. The filter can be easily removed and when washed regularly, deodorising effectiveness should last for more than 10 years. MSZ-G and MSZ-HC wall mounted and MFZ floor mounted systems are supplied with or have the option of the Catechin filter.

Anti-Allergy Enzyme Filter mechanism


s Artificial enzyme catalyst on the filament catches the allergens. s The artificial enzyme catalyst helps the chemical reaction with Oxygen and severs the S-S bonds.*1 s Proteins with severed S-S bonds are no longer allergen proteins.
*1 Mites and other allergen protein consist of sulfur atoms (S) that have bonded together.

Silent Operation
Technological improvements reducing operating sound levels
Only 20dBA
Unlike conventional models with a grilled air intake, wall mounted models feature a smoothly contoured, flat panel finish with a top air intake that not only improves aesthetics, but also helps to reduce noise as the heat exchanger area is fully covered. In fact, noise level during normal operation is only 20dBA for the MSZ-FD25VA, making it one of the quietest indoor units on the market. This is as a result of the multi-angled heat exchanger having a modified fin shape that reduces air resistance, producing a smoother, quieter flow of air. Alongside this, the wide diameter of the fan produces greater airflow at lower fan speeds and the uneven pitch between each fan blade helps to eliminate unwanted noise.

Page 16

Operating Status Monitoring


Monitor lamps located on the right of the indoor unit provide at-a-glance recognition of the air conditioner operating status. When the difference between the set temperature and room temperature is more than 2C, both monitor lamps will turn on. If it is less than 2C, only the upper lamp will light.

Quick Clean Design


The vane on the MSZ-GC22-35/GB50VA and MSZ-FD25/35VA wall mounted models easily detaches, allowing access to the louvres. These can then be opened outwards (without any special tools) for quick cleaning of the heat exchanger, fan and air vents. Regular cleaning will increase both operating efficiency and energy-savings.

Quick Clean Design can reduce your electricity bill by approximately 30%
Electricity bill increases by 5%*1 Electricity bill increases by 25%*1

Heat Exchanger

Fan

Air Vent

*1 Electricity bill comparison of operation under a fixed


temperature with 8g of soil on the fan and also without.

Page 17

The New MSZ-FD Series


The new FD Series line-up is engineered for high energy efficiency and low sound levels. The I-See Sensor, Plasma-Duo filter system and other superb new functions raise the comfort level to even greater heights.

High Energy Efficiency


With the latest inverter technology, energy efficiency is improved by about 20%. Specifically, more than 5.0 is attained for both the COP and EER for a size 25.

Quiet Running
A larger line flow fan is included in the FD model. This allows stable capacity with fewer rotations, reducing operating noise.

Powerful Heating Capacity


The VAH outdoor unit is engineered for use in cold regions and is equipped with a powerful compressor, enabling an improvement in heating capacity. The heating power is raised by about 30% over the standard model and keeps the room comfortable even on cold days. Field Test Result: Size 35. Sweden, 23rd January 2008

Page 18

The "I-See Sensor" automatically moves from side to side, searching floor temperature over a wide area of 150.
Conventional air conditioners control indoor temperature by using only the temperature of the intake air at the top of the room. As a result, the floor level temperature, which exerts such a crucial impact on the temperature that people feel, tends to be overlooked. The I-See Sensor detects the floor temperatures to ensure constant comfort in the living areas.

Cold air tends to sink to floor level, which is often the cause of over cooling. The I-See Sensor tracks this floor level temperature and adjusts the air outlet temperature accordingly.

Warm air tends to rise up from the floor level, which often prevents that zone from warming up. The I-See Sensor tracks this floor level temperature and adjusts the air outlet flow accordingly.

Besides a pre-filter, the MSZ-FD is also fitted with two plasma air-purifying functions. These functions are engineered to change air dirt particles from micron to nano-size in scale.

Plasma Electrode Unit


A plasma electrode unit is mounted inside the air conditioner. Electro-discharge is used to generate ozone & plasma. The collaboration between ozone & plasma and two special filters creates a dynamic plasma air cleaning function.

Plasma Air Purification Plasma Deodorisation


The Platinum catalyst deodorising filter captures small foul-smelling substances in the air, then breaks down the source of the odours with the power of the ozone generated in the plasma electrode unit and the platinum catalyst contained in the filter. The Anti-allergen electric enzyme filter uses the power of the static electricity charged in the filter, as well as plasma generated in the plasma electrode unit to capture the bacteria, pollen and other allergens in the air, which are then neutralised by the enzyme in the filter.

The MSZ-FD is equipped with a Mould Fighter function designed to suppress the growth of spores of mould. The ozone generated in the plasma electrode unit attacks the mould spores, reducing mould growth by about 20%. Mould Fighter mechanism Step 1
After cooling operation the Plasma Electrode unit fills the inside of the indoor unit with ozone (O3).

Step 2
The heat exchanger is dried for about 40mins by the fan mode operation.

Page 19

MXZ Multi-Split Systems


The MXZ-8A140VA Power Multi Inver ter Heat Pump Multi-Split Outdoor Unit

Ideal for apartments or small commercial buildings

s s

14kW Inverter Multi System, based on Mr Slim Power Inverter technology Ability to connect up to eight indoor units across the M Series and Mr Slim product range within a capacity index of 18.5kW Total Pipe Length of 115m / Height Difference of 30m
A rated energy label - High COP (3.91) & EER (3.52)

s s s s

Single phase power supply Connection of indoor units is through either a 3-way (PAC-AK30BC) or 5-way (PAC-AK50BC) branch box, either singularly or with two in combination Individual control of each indoor unit is now possible (ON/OFF and Setpoint) Low starting and running currents Connection to M-NET system via MAC-399IF-E interface (one per indoor unit needed) New Centralised Simple ON/OFF remote controller MAC-821SC-E available for use on all MXZ Multi-Split units. Up to eight indoor units can be controlled from one remote controller (Interface MAC-397IF-E is needed, one per indoor unit)

s s s s

Page 20

All Mitsubishi Electric MXZ Multi-Split models have an energy label of A


Example of Power Multi System using eight indoor units
Outdoor Unit

Branch Box

Branch Box

Page 21

Excellent

Features
Available in wall and floor mounted, the M Series range is quiet, economic to run and easy to install. The outdoor units can run up to eight indoor units, all controlled with a simple remote controller. Whatever your requirements may be, Mitsubishi Electric offers the perfect air conditioning solution for any situation.

Simple technology
at its best
Systems marked with the ECA logo have an energy label of A or B, are registered on the Energy Technology List and hence qualify for 100% first year enhanced capital allowances (whole system cost and reasonable cost of installation). For further information please go to www.eca.gov.uk

Nominal conditions cooling: indoor 27C DB, 19C WB; outdoor 35C DB, 24C WB. Nominal conditions heating: indoor 20C DB; outdoor 7C DB, 6C WB. UK Conditions: Summer; indoor 21C DB, 15C WB; outdoor 27C DB. Winter; indoor 21C DB; outdoor -1C WB.

Page 22

Contents
24 26 28 30 32 34 36 50 52

MSZ-HC-VA(B) Inverter Heat Pump, Wall Mounted System MSH-GA-VB Heat Pump, Wall Mounted System MSZ-GA/GB/GC-VA Inverter Heat Pump, Wall Mounted System MSZ-FD-VA Inverter Heat Pump, Wall Mounted System MFZ-KA-VA Inverter Heat Pump, Floor Mounted System MXZ-A-VA Multi-Split Inverter Heat Pump MXZ-8A140VA Power Multi Inverter Heat Pump Outdoor Units M Series Accessories / Optional Extras

Page 23

MSZ-HC-VA(B) Inverter Heat Pump


Classic Wall Mounted System
Mitsubishi Electrics new range of high specification, flat panel wall mounted models make use of inverter technology, whilst providing extremely good value for money, costing approximately 20% less than the MSZ-G equivalent. These units have extremely quiet sound levels, whilst also delivering economical air conditioning, with improved COP/EER figures and in many cases corresponding A rated energy labels.

* Catechin filter is optional * Air cleaning filter is optional

Technical Information
MSZ-HC-VA(B) - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) COP / EER (nominal) ENERGY LABEL AIRFLOW (m3/min) PIPE SIZE mm(in) NOISE (dBA) DIMENSIONS (mm) Heating/Cooling Heating/Cooling - Lo-Mi-Hi-SupHi Gas Liquid Heating/Cooling - Lo-Mi-Hi-SupHi Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE RUNNING CURRENT (A) FUSE RATING (BS88) - HRC (A) INTERCONNECTING CABLE No. CORES MSZ-HC25VA 3.2 (0.9-4.4) 2.5 (0.9-3.0) 2.65 (0.75-3.65) 2.5 (0.9-3.0) 0.79 3.64 / 3.25 A /A 5.1-6.5-7.8-9.1 / 5.3-7.0-8.7-10.5 9.52(3/8) 6.35(1/4) 26-32-38-43 / 26-32-38-43 788 225 295 9 Fed by Outdoor Unit Single 0.22 6 4 MSZ-HC35VAB 3.6 (0.9-4.8) 3.4 (1.0-3.7) 3.0 (0.75-4.0) 3.35 (1.0-3.65) 0.76 3.62 / 3.01 A/B 4.9-6.7-8.0-9.2 / 5.2-6.8-8.4-10.2 9.52(3/8) 6.35(1/4) 26-32-38-43 / 26-32-38-43 788 225 295 9 Fed by Outdoor Unit Single 0.22 6 4

MUZ-HC-VA(B) - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. CORES MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 7m Heating/Cooling MUZ-HC25VA 47 / 46 25 684 255 540 220-240v, 50Hz Single 0.88 / 0.77 0.801 / 0.616 4.2 4.2 / 3.7 [5.5] 16 3 10 5 0.73 MUZ-HC35VAB 48 / 47 25 684 255 540 220-240v, 50Hz Single 0.995 / 1.13 0.905 / 0.904 5.3 4.8 / 5.3 [6.5] 16 3 10 5 0.75

Page 24

INDOOR UNIT MSZ-HC25/35VA(B)

Upper View

>

Front View

>

Side View

>

Page 25

MSZ-HC-VA(B) Inverter Heat Pump

M Series Range 2008

Dimensions

MSH-GA-VB Heat Pump


Classic Wall Mounted System
Mitsubishi Electrics range of high specification, flat panel wall mounted models make use of traditional fixed speed technology, whilst providing extremely good value for money, costing approximately 30% less than the inverter equivalent. These units have extremely quiet sound levels, whilst also delivering economical air conditioning. Ideal for use in any size room, both units come equipped with a wide-angle airflow system, as well as an automatic swing vane, allowing airflow to be extended to every corner of a room.

* Air cleaning filter is optional

Technical Information
MSH-GA-VB - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) COP / EER (nominal) ENERGY LABEL AIRFLOW (m3/min) PIPE SIZE mm(in) NOISE (dBA) DIMENSIONS (mm) Heating/Cooling Heating/Cooling - Lo-Mi-Hi-SupHi Gas Liquid Heating/Cooling - Lo-Mi-Hi-SupHi Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE RUNNING CURRENT (A) FUSE RATING (BS88) - HRC (A) INTERCONNECTING CABLE No. CORES MSH-GA50VB 5.2 5.0 4.3 4.95 0.65 3.23 / 2.81 C/C 8.8-10.7-12.8 / 8.8-10.7-12.8 12.7(1/2) 6.35(1/4) 34-38-42 / 34-38-42 1100 258 325 16 220-240v, 50Hz Single 0.30 6 2 Core 12v MSH-GA60VB 7.2 6.3 6.0 6.25 0.64 2.90 / 2.61 D/D 8.8-10.7-12.8 / 9.8-11.2-12.8 15.88(5/8) 6.35(1/4) 34-40-45 / 37-41-45 1100 258 325 16 220-240v, 50Hz Single 0.30 6 2 Core 12v

MUH-GA-VB - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) RUNNING CURRENT (A) [MAX] Heating/Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. CORES MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 7m Heating/Cooling MUH-GA50VB 52 / 52 47 850 290 605 220-240v, 50Hz Single 1.61 / 1.78 1.465 / 1.424 37 7.23 / 7.93 [12.9] 16 3 25 10 1.80 MUH-GA60VB 53 / 53 74 840 330 850 220-240v, 50Hz Single 2.48 / 2.41 2.257 / 1.928 74 10.70 / 10.39 [16.5] 25 3 25 10 2.35

Notes: MSH-GA50/60VB indoor units require a 240v, 50hz single phase supply and the outdoor units require the same, separate supply. Between the indoor and outdoor unit is a 2 Core, low voltage interconnecting cable. Page 26

INDOOR UNIT MSH-GA50/60VB

Upper View

>

Side View

>

Front View

>

Page 27

MSH-GA-VB Heat Pump

M Series Range 2008

Dimensions

MSZ-GA/GB/GC-VA Inverter Heat Pump


Wall Mounted System
The MSZ series has been completely redesigned and features the new Catechin filter system. These models also offer industry leading noise levels and have a distinctively styled front panel that not only looks appealing but also helps to make cleaning of the unit easier.

* Wide swing & long airflow mode available for MSZ-GA60/71VA * The anti-allergy enzyme filter is optional * Quick clean design available for MSZ-GC22-35/GB50VA

Technical Information
MSZ-GA/GB/GC-VA - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) COP / EER (nominal) ENERGY LABEL AIRFLOW (m3/min) PIPE SIZE mm(in) Heating/Cooling Heating/Cooling - Lo-Mi-Hi-SupHi Gas Liquid NOISE (dBA) DIMENSIONS (mm) Heating/Cooling - Lo-Mi-Hi-SupHi Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. CORES

MSZ-GC22VA
3.3 2.2 2.75 2.2 -

MSZ-GC25VA
3.2 (0.9-4.5) 2.5 (0.9-3.0) 2.65 (0.75-3.75) 2.5 (0.9-3.0) 0.79 3.83 / 3.76 A /A

MSZ-GC35VA
4.0 (0.9-5.0) 3.5 (1.0-3.9) 3.3 (0.75-4.15) 3.45 (1.0-3.85) 0.76 3.79 / 3.26 A /A

MSZ-GB50VA
5.8 (0.9-7.8) 5.0 (0.9-5.8) 4.8 (0.75-6.5) 4.95 (0.9-5.75) 0.69 3.41 / 3.03 B/B

MSZ-GA60VA
6.8 (0.9-8.1) 6.0 (0.9-6.7) 5.65 (0.75-6.75) 5.95 (0.9-6.65) 0.79 3.51 / 3.11 B/B

MSZ-GA71VA
8.1 (0.9-9.6) 7.1 (0.9-8.3) 6.75 (0.75-8.0) 7.05 (0.9-8.25) 0.71 3.31 / 2.93 C/C

4.6-6.3-8.0-10.0 / 4.1-5.9-7.7-9.6 4.6-6.3-8.0-10.0 / 4.1-5.9-7.7-9.6 4.1-5.6-7.7-9.5 / 3.9-5.5-7.4-9.2 9.52 (3/8) 6.35 (1/4) 21-29-36-43 788 234 295 9 9.52 (3/8) 6.35 (1/4) 21-29-36-43 788 234 295 9 9.52 (3/8) 6.35 (1/4) 22-29-36-43 788 234 295 9

6.9-7.4-10.9 / 6.9-7.4-10.9 8.7-13.1-17.2 / 8.7-12.8-17.2 9.4-13.6-17.2 / 9.4-13.3-17.2 12.7 (1/2) 6.35 (1/4) 30-36-42-48 / 32-38-44-48 780 210 298 9 15.88 (5/8) 6.35 (1/4) 32-40-54 1100 258 325 16 15.88 (5/8) 9.52 (3/8) 33-40-54 1100 258 325 16

Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Single 6 4 Single 6 4 Single 6 4 Single 6 4 Single 6 4 Single 6 4

MUZ-GA/GB/GC-VA - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling FUSE RATING (BS88) HRC (A) MAINS CABLE No. CORES MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 7m Heating/Cooling - Lo-Hi

N/A Multi-Split Only


-

MUZ-GC25VA
47 / 46 26 684 255 540 220-240v, 50Hz 0.835 / 0.665 0.76 / 0.532 4.2 4.2 / 3.6 [5.8] 16 3 20 12 0.75

MUZ-GC35VA
48 / 47 31 800 285 550 220-240v, 50Hz 1.055 / 1.075 0.96 / 0.86 5.0 4.9 / 5.0 [6.5] 16 3 20 12 0.85

MUZ-GB50VA
53-55 / 51-52 53 840 330 850 220-240v, 50Hz 1.70 / 1.65 1.55 / 1.32 7.46 7.78 / 7.58 [16] 25 3 30 15 1.5

MUZ-GA60VA
53-55 / 51-53 53 840 330 850 220-240v, 50Hz 1.94 / 1.93 1.77 / 1.54 8.93 8.93 / 8.83 [16] 25 3 30 15 1.8

MUZ-GA71VA
53-55 / 51-53 58 840 330 850 220-240v, 50Hz 2.45 / 2.42 2.23 / 1.94 11.2 11.2 / 11.0 [16] 25 3 30 15 2.0

Page 28

INDOOR UNIT MSZ-GC22-35VA


Upper View

>
Side View

>

Front View

>

INDOOR UNIT MSZ-GB50VA


Upper View

>
Side View

>

Front View

>

INDOOR UNIT MSZ-GA60/71VA


Upper View

>

Side View Front View

>

>

Page 29

MSZ-GA/GB/GC-VA Inverter Heat Pump

M Series Range 2008

Dimensions

MSZ-FD-VA Inverter Heat Pump


Wall Mounted System
The MSZ-FD series is our most energy efficient M Series wall mounted unit to date. These high COP models feature the new Plasma Duo filter system. These models also offer industry leading noise levels and have a distinctively styled front panel that not only looks appealing but also helps to make cleaning of the unit easier. Also incorporated is an I-See Sensor, providing even temperature distribution and further reducing energy consumption.

Technical Information
MSZ-FD-VA - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) COP / EER (nominal) ENERGY LABEL AIRFLOW (m3/min) PIPE SIZE mm(in) Heating/Cooling Heating/Cooling - Lo-Mi-Hi-SupHi Gas Liquid NOISE (dBA) DIMENSIONS (mm) Heating/Cooling - Lo-Mi-Hi-SupHi Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. CORES

MSZ-FD25VA
3.2 (1.5-6.3) 2.5 (1.1-3.5) 2.65 (1.25-5.25) 2.5 (1.1-3.45) 0.85 5.25 / 5.15 A /A 4.5-6.7-9.2-12.1 / 4.6-6.3-8.6-11.2 9.52 (3/8) 6.35 (1/4) 20-29-36-43 / 20-29-36-42 798 257 295 12 Fed by Outdoor Unit Single 6 4

MSZ-FD35VA
4.0 (1.3-7.7) 3.5 (0.8-4.0) 3.3 (1.1-6.4) 3.45 (0.8-3.95) 0.85 4.71 / 4.19 A /A 4.7-6.7-9.2-12.5 / 4.6-6.3-8.6-11.2 9.52 (3/8) 6.35 (1/4) 21-29-36-44 / 21-29-36-43 798 257 295 12 Fed by Outdoor Unit Single 6 4

MUZ-FD-VAH - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling FUSE RATING (BS88) HRC (A) MAINS CABLE No. CORES MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 7m Heating/Cooling

MUZ-FD25VAH
46 / 46 36 800 285 550 220-240v, 50Hz 0.61 / 0.485 0.555 / 0.388 2.9 2.9 / 2.4 [9.2] 16 3 20 12 1.15

MUZ-FD35VAH
50 / 47 36 800 285 550 220-240v, 50Hz 0.85 / 0.835 0.774 / 0.668 3.9 3.9 / 3.8 [10.5] 16 3 20 12 1.15

Page 30

INDOOR UNIT MSZ-FD25/35VA


Upper View

>

Front View

>

Side View

>

Page 31

MSZ-FD-VA Inverter Heat Pump

M Series Range 2008

Dimensions

MFZ-KA-VA Inverter Heat Pump


Floor Mounted System
The MFZ-KA-VA series is extremely versatile and is designed for wall attached installation at floor level. The auto swing vane provides a more natural and comfortable airflow throughout the room and the lightweight, compact design makes installation easy.

Technical Information
MFZ-KA-VA - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) COP / EER (nominal) ENERGY LABEL AIRFLOW (m3/min) PIPE SIZE mm(in) Heating/Cooling Heating/Cooling - Lo-Mi-Hi-SupHi Gas Liquid NOISE (dBA) DIMENSIONS (mm) Heating/Cooling - Lo-Mi-Hi-SupHi Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. CORES MFZ-KA25VA 3.4 (0.9-5.1) 2.5 (0.9-3.4) 2.85 (0.75-4.25) 2.5 (0.9-3.35) 0.66 4.07 / 4.31 A /A 5.0-6.2-7.6-9.1 / 4.8-5.8-7.1-8.7 9.52 (3/8) 6.35 (1/4) 22-27-32-37 / 22-27-32-37 700 200 600 14 Fed by Outdoor Unit Single 6 4 MFZ-KA35VA 4.0 (0.9-6.2) 3.5 (0.9-3.9) 3.3 (0.75-5.15) 3.45 (0.9-3.85) 0.65 3.64 / 3.21 A /A 5.2-6.2-7.8-9.5 / 5.0-6.1-7.4-9.1 9.52 (3/8) 6.35 (1/4) 25-28-33-38 / 23-28-33-38 700 200 600 14 Fed by Outdoor Unit Single 6 4 MFZ-KA50VA 6.0 (0.9-7.9) 4.8 (0.9-5.4) 5.0 (0.75-6.55) 4.75 (0.9-5.35) 0.63 3.23 / 3.10 C/B 7.4-8.8-9.8-11.8 / 7.1-7.9-9.2-10.7 12.7 (1/2) 6.35 (1/4) 32-35-39-44 / 32-35-39-43 700 200 600 14 Fed by Outdoor Unit Single 6 4

SUZ-KA-VA - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. CORES MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 7m Heating/Cooling SUZ-KA25VA 46 / 46 33 800 285 550 220-240v, 50Hz 0.835 / 0.58 0.76 / 0.46 3.8 4.0 / 2.8 [9.2] 16 3 20 12 0.9 SUZ-KA35VA 48 / 47 37 800 285 550 220-240v, 50Hz 1.10 / 1.09 1.00 / 0.87 4.8 5.0 / 5.0 [10.3] 16 3 20 12 1.05 SUZ-KA50VA 55 / 53 53 840 330 850 220-240v, 50Hz 1.86 / 1.55 1.69 / 1.24 8.3 8.5 / 7.0 [17.8] 25 3 30 15 1.6

Page 32

INDOOR UNIT MFZ-KA25-50VA

Upper View

>

Front View

>

Side View

>
MFZ-KA-VA Inverter Heat Pump
Page 33

M Series Range 2008

Dimensions

MXZ-A-VA Inverter Heat Pump (5.2 - 10.0kW)


Multi-Split Units
The multi-split system allows up to five M Series or Mr Slim wall mounted, cassette, ducted, floor or ceiling mounted indoor unit heat-pumps of different capacities to be operated from a single outdoor unit. This makes it an economic answer in multi-room applications, whilst also offering space saving benefits.
s s s s s

Up to five indoor units may be connected to a single outdoor unit Energy saving inverter controlled outdoor unit adjusts compressor performance to economically match the demand for heating and cooling Units may be added within the capacity of the system as requirements change Single outdoor unit for minimal noise and space impact Capacities of indoor units may be mixed to suit individual rooms

Technical Information
MULTI-SPLIT - INDOOR UNITS
MODEL REFERENCE
WALL MOUNTED MSZ-GC22/25/35VA MSZ-FD25/35VA MSZ-GC22/25/35VA MSZ-GB50VA MSZ-FD25/35VA MSZ-GC22/25/35VA MSZ-GB50VA MSZ-GA60VA MSZ-FD25/35VA MSZ-GC22/25/35VA MSZ-GB50VA MSZ-GA60/71VA MSZ-FD25/35VA MSZ-GC22/25/35VA MSZ-GB50VA MSZ-GA60/71VA MSZ-FD25/35VA FLOOR MOUNTED MFZ-KA25/35VA DUCTED SEZ-KD25/35VA SEZ-KD25/35/50VA PEAD-RP50EA SEZ-KD25/35/50/60VA PEAD-RP50EA SEZ-KD25/35/50/60/71VA PEAD-RP50EA SEZ-KD25/35/50/60/71VA PEAD-RP50EA CEILING CASSETTE SLZ-KA25/35VA SLZ-KA25/35/50VA PLA-RP50BA SLZ-KA25/35/50VA PLA-RP50/60BA SLZ-KA25/35/50VA PLA-RP50/60/71BA SLZ-KA25/35/50VA PLA-RP50/60/71BA CEILING SUSPENDED

MXZ-2A52VA MXZ-3A54VA MXZ-4A71VA MXZ-4A80VA MXZ-5A100VA


MXZ-A-VA - OUTDOOR UNITS
MODEL REFERENCE
NUMBER OF CONNECTABLE INDOOR UNITS CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) COP / EER (nominal) ENERGY LABEL MAX AIRFLOW (m3/min) NOISE (dBA) DIMENSIONS (mm) Heating/Cooling Heating/Cooling Heating/Cooling - Lo-Hi Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) RUNNING CURRENT (A) [MAX] Heating/Cooling INTERCONNECTING CABLE No. CORES TOTAL PIPE LENGTH (m) MAX PIPE LENGTH PER INDOOR UNIT (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 40m (20m for MXZ-2A52VA) FUSE RATING (BS88) HRC (A)

MFZ-KA25/35/50VA

PCA-RP50GA2

MFZ-KA25/35/50VA

PCA-RP50/60GA(2)

MFZ-KA25/35/50VA

PCA-RP50/60/71GA(2)

MFZ-KA25/35/50VA

PCA-RP50/60/71GA(2)

MXZ-2A52VA 2 6.4 (1.0-7.2) 5.2 (1.1-6.0) 5.3 (0.85-6.0) 5.15 (1.1-5.95) 3.75 / 3.46 A /A 31 / 31 48-50 / 45-49 800 285 550 40 220-240v, 50Hz 1.705 / 1.505 1.55 / 1.2 7.64 7.64 / 6.75 [10.2] 4 Core 30 20

MXZ-3A54VA 2-3 6.8 (2.6-9.0) 5.4 (2.9-6.8) 5.65 (2.15-7.5) 5.35 (2.9-6.75) 4.67 / 4.17 A /A 41.2 / 42.1 47-48 / 44-46 840 330 710 57 220-240v, 50Hz 1.455 / 1.295 1.32 / 1.04 6.39 6.39 / 5.69 [16.4] 4 Core 50 25

MXZ-4A71VA 2-4 8.6 (3.4-9.0) 7.1 (3.7-8.8) 7.15 (2.85-7.5) 7.05 (3.65-8.75) 4.41 / 3.68 A /A 46.5 / 42.1 48-50 / 45-48 840 330 710 58 220-240v, 50Hz 1.95 / 1.93 1.77 / 1.54 8.56 8.56 / 8.48 [16.4] 4 Core 60 25

MXZ-4A80VA 2-4 9.4 (3.4-11.6) 8.0 (3.7-9.2) 7.8 (2.85-9.65) 7.95 (3.65-9.15) 4.87 / 3.65 A /A 43.8 / 42.2 46-48 / 44-46 900 320 900 67 220-240v, 50Hz 1.93 / 2.19 1.76 / 1.75 9.62 8.48 / 9.62 [17.4] 4 Core 70 25

MXZ-5A100VA 2-5 12.0 (3.4-14.0) 10.0 (3.7-11.0) 9.95 (2.85-11.65) 9.9 (3.65-10.9) 4.23 / 3.41 A /A 59.3 / 56.6 46-54 / 45-51 900 320 900 68 220-240v, 50Hz 2.835 / 2.935 2.58 / 2.35 12.88 12.45 / 12.88 [19.4] 4 Core 80 25

15 (10 if Outdoor higher than Indoor) 15 (10 if Outdoor higher than Indoor) 15 (10 if Outdoor higher than Indoor) 15 (10 if Outdoor higher than Indoor) 15 (10 if Outdoor higher than Indoor) 1.3 16 2.7 25 2.7 25 3.5 25 4.0 25

Page 34

OUTDOOR UNIT MXZ-2A52VA

Upper View

>

Front View

>

Side View

>

OUTDOOR UNIT MXZ-3A54VA / MXZ-4A71VA

Upper View

>

Front View

>

Side View

>
D connection for MXZ-4A71VA

OUTDOOR UNIT MXZ-4A80VA / MXZ-5A100VA

Upper View

>

Front View

>

Side View

>
E connection for MXZ-5A100VA

Page 35

MXZ-A-VA Multi-Split Inverter Heat Pump (5.2 -10.0kW)

M Series Range 2008

Dimensions

MXZ-8A140VA Power Multi (14kW)


Inverter Heat Pump Multi-Split Unit
The Power Multi system allows up to eight M Series or Mr Slim cassette, ducted, floor, ceiling or wall mounted indoor units of different capacities to be operated from a single outdoor unit, making use of two types of branch box to achieve this. This makes it an economic answer in multi-room applications and ideal for apartments or small commercial buildings.
s s s s s s

14kW Inverter Multi System, based on Mr Slim Power Inverter technology Total Pipe length of 115m / Height difference of 30m Individual control of each indoor unit is now possible (ON/OFF & Setpoint) Low starting and running currents Connection to M-NET system via MAC-399IF interface (one per indoor unit) New Centralised Simple ON/OFF remote controller MAC-821SC-E available to control up to 8 indoor units (interface MAC-397IF is needed, one per indoor unit)

Technical Information
MULTI-SPLIT - INDOOR UNITS
MODEL REFERENCE
WALL MOUNTED MSZ-GC22/25/35VA MSZ-GB50VA MSZ-GA60/71VA MSZ-FD25/35VA FLOOR MOUNTED DUCTED SEZ-KD25/35/50/60/71VA MFZ-KA25/35/50VA PEAD-RP50/60/71EA PLA-RP35/50/60/71BA(2) CEILING CASSETTE SLZ-KA25/35/50VA

MXZ-8A140VA

MXZ-8A140VA - OUTDOOR UNIT


MODEL REFERENCE
NUMBER OF CONNECTABLE INDOOR UNITS CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) COP / EER (nominal) ENERGY LABEL MAX AIRFLOW (m3/min) NOISE (dBA) DIMENSIONS (mm) Lo-Hi Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) RUNNING CURRENT (A) [MAX] Heating/Cooling INTERCONNECTING CABLE No. CORES TOTAL PIPE LENGTH (m) MAX PIPE LENGTH PER INDOOR UNIT (m) FURTHEST PIPE LENGTH - Outdoor to Indoor (m) MAX HEIGHT DIFFERENCE - Outdoor to Indoor (m) MAX HEIGHT DIFFERENCE - Indoor to Indoor (m) CHARGE R410A (kg) - 40m FUSE RATING (BS88) HRC (A) Heating/Cooling MXZ-8A140VA 2-8 16.0 14.0 13.3 13.9 4.10 / 3.69 A /A 100 52 / 50 950 330 (+30) 1350 128 220-240v, 50Hz 3.90 / 3.79 3.55 / 3.03 14 16.33 / 15.86 [29.5] 4 Core 115 15 (from Branch Box) 70 30 (20 if Outdoor lower than Indoor) 12 8.5 40

PAC-AK30BC - BRANCH BOX


MODEL REFERENCE
NUMBER OF CONNECTABLE INDOOR UNITS POWER SUPPLY TO BRANCH BOX POWER SUPPLY TO INDOOR UNITS PIPE SIZE mm(in) Main Outdoor Side - Gas PIPE SIZE mm(in) Main Outdoor Side - Liquid MAX PIPE LENGTH - Outdoor Unit to Branch Box (m) TOTAL PIPE LENGTH - Branch Boxes to Indoor Unit (m) MAX HEIGHT DIFFERENCE - Outdoor Unit to Branch Box (m) MAX HEIGHT DIFFERENCE - Branch Box to Indoor Unit (m) DIMENSIONS (mm) Width Depth Height PAC-AK30BC 1-3 From Outdoor Unit From Branch Box 15.88(5/8) 9.52(3/8) 55 60 30 15 450 280 198

PAC-AK50BC - BRANCH BOX


MODEL REFERENCE
NUMBER OF CONNECTABLE INDOOR UNITS POWER SUPPLY TO BRANCH BOX POWER SUPPLY TO INDOOR UNITS PIPE SIZE mm(in) Main Outdoor Side - Gas PIPE SIZE mm(in) Main Outdoor Side - Liquid MAX PIPE LENGTH - Outdoor Unit to Branch Box (m) TOTAL PIPE LENGTH - Branch Boxes to Indoor Unit (m) MAX HEIGHT DIFFERENCE - Outdoor Unit to Branch Box (m) MAX HEIGHT DIFFERENCE - Branch Box to Indoor Unit (m) DIMENSIONS (mm) Width Depth Height PAC-AK50BC 1-5 From Outdoor Unit From Branch Box 15.88(5/8) 9.52(3/8) 55 60 30 15 450 280 198

Page 36

OUTDOOR UNIT MXZ-8A140VA


Upper View

>

Front View

>

Side View

>

BRANCH BOX PAC-AK30BC


Front View

>

Side View

>

Upper View

>

BRANCH BOX PAC-AK50BC


Front View

>

Side View

>

Upper View

>

Page 37

MXZ-8A140VA Power Multi Inverter Heat Pump (14kW)

M Series Range 2008

Dimensions

Inverter Multi-Split Systems


MXZ-3A54/4A71VA Inverter Multi units MXZ-4A80/5A100VA Inverter Multi units

MXZ-2A52VA Inverter Multi unit

Outdoor Units
MSZ-GA/GB/GC-VA Series

MXZ-8A140VA Power Multi unit

Indoor Units
MSZ-FD-VA Series PCA-RP-GA(2) Series

30

PEAD-RP-EA Series

PLA-RP-BA(2) Series MFZ-KA-VA Series SEZ-KD-VA Series

SLZ-KA-VA Series

Page 38

Multi-Split systems allow up to eight M Series or Mr Slim cassette, ducted, floor, ceiling or wall mounted indoor units of different capacities to be operated from a single outdoor unit

Inverter Multi-Split System Combinations


MXZ-2A52VA
1 Outdoor Unit
Indoor unit combination

MXZ-4A71VA
1 Outdoor Unit
Indoor unit combination

2 Indoor Units
Cooling / Heating Capacity (kW) Unit A Unit B Unit C

Up to 4 Indoor Units
Cooling / Heating Capacity (kW) Unit A Unit B Unit C Unit D

1 ROOM
22 25 35 2.20 / 3.30 2.50 / 3.60 3.50 / 4.00

1 ROOM
22 25 35 50 2.20 2.20 1.93 2.50 2.13 2.60 / / / / / / 3.05 2.90 2.43 3.15 2.63 3.20 2.20 2.50 3.07 2.50 2.97 2.60 / / / / / / 3.05 3.30 3.87 3.15 3.67 3.20 60 2.20 / 3.30 2.50 / 3.60 3.50 / 4.00 5.00 / 7.20 6.00 / 7.90

2 ROOMS
22 22 22 25 25 35 + + + + + + 22 25 35 25 35 35

2 ROOMS
22 + 22 22 + 25 22 + 35 22 + 50 22 + 60 25 + 25 25 + 35 25 + 50 25 + 60 35 + 35 35 + 50 35 + 60 50 + 50 50 + 60 60 + 60 2.20 / 3.30 2.20 / 3.23 2.20 / 2.82 2.08 / 2.63 1.82 / 2.31 2.50 / 3.60 2.50 / 3.17 2.27 / 2.87 2.00 / 2.53 3.40 / 4.30 2.80 / 3.54 2.51 / 3.17 3.40 / 4.30 3.09 / 3.91 3.40 / 4.30 2.20 / 3.30 2.50 / 3.67 3.50 / 4.48 4.72 / 5.97 4.98 / 6.29 2.50 / 3.60 3.50 / 4.43 4.53 / 5.73 4.80 / 6.07 3.40 / 4.30 4.00 / 5.06 4.29 / 5.43 3.40 / 4.30 3.71 / 4.69 3.40 / 4.30

MXZ-3A54VA
1 Outdoor Unit
Indoor unit combination

Up to 3 Indoor Units
Cooling / Heating Capacity (kW) Unit A Unit B Unit C

1 ROOM
22 25 35 50 2.20 2.50 3.50 5.00 / / / / 3.30 3.60 4.00 6.80

3 ROOMS
22 + 22 + 22 2.20 / 2.87 2.20 / 2.74 1.98 / 2.39 1.66 / 2.01 1.50 / 1.82 2.16 / 2.62 1.91 / 2.31 1.61 / 1.95 1.46 / 1.77 1.70 / 2.06 1.46 / 1.77 1.34 / 1.62 1.28 / 1.56 2.36 / 2.86 2.09 / 2.53 1.78 / 2.15 1.61 / 1.95 1.86 / 2.26 1.61 / 1.95 1.48 / 1.79 1.42 / 1.72 2.36 / 2.86 2.07 / 2.51 2.20 / 2.87 2.20 / 2.74 1.98 / 2.39 1.66 / 2.01 1.50 / 1.82 2.47 / 2.99 2.16 / 2.62 1.83 / 2.22 1.66 / 2.01 2.70 / 3.27 2.32 / 2.81 2.12 / 2.57 2.91 / 3.52 2.36 / 2.86 2.09 / 2.53 1.78 / 2.15 1.61 / 1.95 2.62 / 3.17 2.26 / 2.74 2.07 / 2.51 2.84 / 3.44 2.36 / 2.86 2.07 / 2.51 2.20 / 2.87 2.50 / 3.12 3.14 / 3.82 3.78 / 4.58 4.10 / 4.96 2.47 / 2.99 3.03 / 3.67 3.66 / 4.43 3.98 / 4.82 2.70 / 3.27 3.32 / 4.02 3.64 / 4.41 2.91 / 3.52 2.36 / 2.86 2.92 / 3.54 3.54 / 4.30 3.88 / 4.68 2.62 / 3.17 3.23 / 3.91 3.55 / 4.30 2.84 / 3.44 2.36 / 2.86 2.96 / 3.58 22 + 22 + 25 2.20 2.50 3.32 3.75 2.50 3.15 3.60 2.70 3.18 2.70 / / / / / / / / / / 3.30 3.62 4.18 4.72 3.40 3.97 4.53 3.40 4.00 3.40

2 ROOMS
22 22 22 22 25 25 25 35 35 50 + + + + + + + + + + 22 25 35 50 25 35 50 35 50 50 2.20 2.20 2.08 1.65 2.50 2.25 1.80 2.70 2.22 2.70 / / / / / / / / / / 3.30 3.18 2.62 2.08 3.40 2.83 2.27 3.40 2.80 3.40

22 + 22 + 35 22 + 22 + 50 22 + 22 + 60 22 + 25 + 25 22 + 25 + 35 22 + 25 + 50 22 + 25 + 60 22 + 35 + 35 22 + 35 + 50 22 + 35 + 60 22 + 50 + 50 25 + 25 + 25 25 + 25 + 35 25 + 25 + 50 25 + 25 + 60 25 + 35 + 35 25 + 35 + 50 25 + 35 + 60 25 + 50 + 50 35 + 35 + 35 35 + 35 + 50

3 ROOMS
22 22 22 22 22 22 22 22 25 25 25 25 + + + + + + + + + + + + 22 22 22 22 25 25 25 35 25 25 25 35 + + + + + + + + + + + + 22 25 35 50 25 35 50 35 25 35 50 35 1.80 1.72 1.50 1.26 1.64 1.45 1.23 1.30 1.80 1.59 1.35 1.42 / / / / / / / / / / / / 2.27 2.17 1.89 1.59 2.08 1.83 1.54 1.62 2.27 2.00 1.70 1.78 1.80 1.72 1.50 1.26 1.88 1.65 1.39 2.05 1.80 1.59 1.35 1.99 / / / / / / / / / / / / 2.27 2.17 1.89 1.59 2.36 2.07 1.75 2.59 2.27 2.00 1.70 2.51 1.80 1.96 2.40 2.88 1.88 2.30 2.78 2.05 1.80 2.22 2.70 1.99 / / / / / / / / / / / / 2.27 2.46 3.02 3.62 2.36 2.90 3.51 2.59 2.27 2.80 3.40 2.51

Page 40

Indoor unit combination

Cooling / Heating Capacity (kW) Unit A Unit B Unit C Unit D

Indoor unit combination

Cooling / Heating Capacity (kW) Unit A Unit B


5.24 / 5.94 5.44 / 6.30 3.95 / 4.70 4.57 / 5.13 4.72 / 5.52 4.00 / 4.70 4.16 / 5.09

Unit C

Unit D

4 ROOMS
22 + 22 + 22 + 22 22 + 22 + 22 + 25 22 + 22 + 22 + 35 22 + 22 + 22 + 50 22 + 22 + 25 + 25 22 + 22 + 25 + 35 22 + 22 + 25 + 50 22 + 22 + 35 + 35 22 + 25 + 25 + 25 22 + 25 + 25 + 35 22 + 25 + 25 + 50 22 + 25 + 35 + 35 25 + 25 + 25 + 25 25 + 25 + 25 + 35 25 + 25 + 25 + 50 25 + 25 + 35 + 35 1.77 / 2.15 1.72 / 2.08 1.55 / 1.87 1.35 / 1.63 1.66 / 2.01 1.50 / 1.82 1.31 / 1.59 1.37 / 1.66 1.61 / 1.94 1.46 / 1.77 1.29 / 1.56 1.34 / 1.62 1.77 / 2.15 1.61 / 1.95 1.42 / 1.72 1.48 / 1.79 1.77 / 2.15 1.72 / 2.08 1.55 / 1.87 1.35 / 1.63 1.66 / 2.01 1.50 / 1.82 1.31 / 1.59 1.37 / 1.66 1.83 / 2.22 1.66 / 2.01 1.45 / 1.76 1.52 / 1.84 1.77 / 2.15 1.61 / 1.95 1.42 / 1.72 1.48 / 1.79 1.77 / 2.15 1.72 / 2.08 1.55 / 1.87 1.35 / 1.63 1.89 / 2.29 1.71 / 2.07 1.50 / 1.81 2.18 / 2.64 1.83 / 2.22 1.66 / 2.01 1.45 / 1.76 2.12 / 2.57 1.77 / 2.15 1.61 / 1.95 1.42 / 1.72 2.07 / 2.51 1.77 / 2.15 1.94 / 2.36 2.45 / 2.98 3.05 / 3.71 1.89 / 2.29 2.39 / 2.89 2.98 / 3.61 2.18 / 2.64 1.83 / 2.22 2.32 / 2.81 2.91 / 3.52 2.12 / 2.57 1.77 / 2.15 2.27 / 2.75 2.84 / 3.44 2.07 / 2.51

35 + 60 35 + 71 50 + 50 50 + 60 50 + 71 60 + 60 60 + 71

2.61 / 3.46 2.51 / 3.10 3.95 / 4.70 3.42 / 4.27 3.27 / 3.88 4.00 / 4.70 3.84 / 4.31

3 ROOMS
22 + 22 + 22 22 + 22 + 25 22 + 22 + 35 22 + 22 + 50 22 + 22 + 60 22 + 22 + 71 22 + 25 + 25 22 + 25 + 35 22 + 25 + 50 22 + 25 + 60 2.20 / 2.90 2.20 / 2.84 2.14 / 2.62 1.72 / 2.20 1.46 / 1.99 1.40 / 1.80 2.20 / 2.72 2.08 / 2.52 1.79 / 2.13 1.64 / 1.93 1.49 / 1.75 1.87 / 2.25 1.63 / 1.93 1.50 / 1.77 1.38 / 1.62 1.44 / 1.70 1.33 / 1.57 1.23 / 1.45 2.50 / 3.00 2.28 / 2.76 1.98 / 2.35 1.82 / 2.14 1.65 / 1.94 2.07 / 2.48 1.82 / 2.14 1.67 / 1.96 1.53 / 1.79 1.60 / 1.88 1.48 / 1.74 2.65 / 3.13 2.33 / 2.74 2.15 / 2.53 1.99 / 2.33 2.08 / 2.44 1.93 / 2.27 2.20 / 2.90 2.20 / 2.81 2.14 / 2.62 1.72 / 2.20 1.46 / 1.99 1.40 / 1.80 2.50 / 3.09 2.36 / 2.87 2.04 / 2.42 1.87 / 2.20 1.69 / 1.99 2.99 / 3.58 2.58 / 3.07 2.40 / 2.81 2.18 / 2.57 3.28 / 3.85 3.03 / 3.56 2.80 / 3.29 2.50 / 3.00 2.28 / 2.76 1.98 / 2.35 1.82 / 2.14 1.65 / 1.94 2.89 / 3.46 2.54 / 2.99 2.33 / 2.74 2.14 / 2.51 3.20 / 3.76 2.96 / 3.48 2.65 / 3.13 2.33 / 2.74 2.15 / 2.53 1.99 / 2.33 2.96 / 3.48 2.76 / 3.24 2.20 / 2.90 2.50 / 3.19 3.42 / 4.16 4.41 / 5.00 5.03 / 5.42 5.20 / 5.80 2.50 / 3.09 3.31 / 4.01 4.07 / 4.85 4.49 / 5.27 4.82 / 5.66 2.99 / 3.58 3.69 / 4.39 4.1 / 4.82 4.44 / 5.21 3.28 / 3.85 3.64 / 4.27 3.97 / 4.67 2.50 / 3.00 3.19 / 3.87 3.94 / 4.70 4.36 / 5.13 4.70 / 5.52 2.89 / 3.46 3.64 / 4.27 4.00 / 4.70 4.33 / 5.09 3.20 / 3.76 3.56 / 4.18 2.65 / 3.13 3.34 / 3.92 3.70 / 4.34 4.02 / 4.74 2.96 / 3.48 3.31 / 3.89

MXZ-4A80VA
1 Outdoor Unit
Indoor unit combination

22 + 25 + 71 22 + 35 + 35 22 + 35 + 50

Up to 4 Indoor Units
Cooling / Heating Capacity (kW) Unit A Unit B Unit C Unit D

22 + 35 + 60 22 + 35 + 71 22 + 50 + 50 22 + 50 + 60

1 ROOM
22 25 35 50 60 71 2.20 / 3.30 2.50 / 3.60 3.50 / 4.00 5.00 / 7.20 6.00 / 7.90 7.10 / 8.60

22 + 50 + 71 25 + 25 + 25 25 + 25 + 35 25 + 25 + 50 25 + 25 + 60 25 + 25 + 71

2 ROOMS
22 + 22 22 + 25 22 + 35 22 + 50 22 + 60 22 + 71 25 + 25 25 + 35 25 + 50 25 + 60 25 + 71 35 + 35 35 + 50 2.20 / 3.30 2.20 / 3.23 2.20 / 2.82 2.20 / 2.72 1.75 / 2.52 1.66 / 2.22 2.50 / 3.60 2.50 / 3.17 2.50 / 3.00 2.11 / 2.76 2.01 / 2.42 3.50 / 4.00 3.10 / 3.87 2.20 / 3.30 2.50 / 3.67 3.50 / 4.48 5.00 / 6.20 6.00 / 6.88 6.19 / 7.18 2.50 / 3.60 3.50 / 4.43 5.00 / 6.00 5.64 / 6.64 5.84 / 6.98 3.50 / 4.00 4.65 / 5.53

25 + 35 + 35 25 + 35 + 50 25 + 35 + 60 25 + 35 + 71 25 + 50 + 50 25 + 50 + 60 35 + 35 + 35 35 + 35 + 50 35 + 35 + 60 35 + 35 + 71 35 + 50 + 50 35 + 50 + 60

Page 41

Indoor unit combination

Cooling / Heating Capacity (kW) Unit A Unit B


1.95 / 2.35 1.90 / 2.27 1.73 / 2.05 1.52 / 1.78 1.40 / 1.64 1.28 / 1.51 1.87 / 2.20 1.68 / 1.99 1.48 / 1.74 1.36 / 1.60 1.26 / 1.48 1.54 / 1.81 1.36 / 1.60 1.12 / 1.49 1.22 / 1.44 2.04 / 2.42 1.86 / 2.20 1.64 / 1.93 1.52 / 1.78 1.71 / 2.01 1.52 / 1.78 1.41 / 1.65 2.20 / 2.59 1.97 / 2.32 1.98 / 2.35 1.82 / 2.14 1.60 / 1.88 1.48 / 1.74 1.67 / 1.96 1.48 / 1.74 2.15 / 2.53 2.00 / 2.35

Indoor unit combination

Cooling / Heating Capacity (kW) Unit A Unit B


2.20 / 3.30 2.50 / 3.67 3.50 / 4.48 5.00 / 6.18 5.67 / 6.88 5.99 / 7.18 2.50 / 3.60 3.50 / 4.43 5.00 / 6.00 5.47 / 7.06 5.81 / 7.40 3.50 / 4.00 4.56 / 5.88 4.96 / 6.32 5.33 / 6.70 3.95 / 5.00 4.36 / 5.45 4.87 / 5.87 4.15 / 5.00 4.61 / 5.42 4.40 / 5.00

Unit C
1.95 / 2.35 1.90 / 2.27 1.73 / 2.05 1.52 / 1.78 1.40 / 1.64 1.28 / 1.51 2.13 / 2.50 1.91 / 2.26 1.68 / 1.97 1.55 / 1.83 1.43 / 1.68 2.46 / 2.89 2.18 / 2.55 1.92 / 2.37 2.78 / 3.26 2.04 / 2.42 1.86 / 2.20 1.64 / 1.93 1.52 / 1.78 2.39 / 2.81 2.12 / 2.49 1.97 / 2.32 2.20 / 2.59 1.97 / 2.32 1.98 / 2.35 1.82 / 2.14 1.60 / 1.88 1.48 / 1.74 2.33 / 2.74 2.08 / 2.44 2.15 / 2.53 2.00 / 2.35

Unit D

Unit C

Unit D

4 ROOMS
22 + 22 + 22 + 22 22 + 22 + 22 + 25 22 + 22 + 22 + 35 22 + 22 + 22 + 50 22 + 22 + 22 + 60 22 + 22 + 22 + 71 22 + 22 + 25 + 25 22 + 22 + 25 + 35 22 + 22 + 25 + 50 22 + 22 + 25 + 60 22 + 22 + 25 + 71 22 + 22 + 35 + 35 22 + 22 + 35 + 50 22 + 22 + 35 + 60 22 + 22 + 50 + 50 22 + 25 + 25 + 25 22 + 25 + 25 + 35 22 + 25 + 25 + 50 22 + 25 + 25 + 60 22 + 25 + 35 + 35 22 + 25 + 35 + 50 22 + 25 + 35 + 60 22 + 35 + 35 + 35 22 + 35 + 35 + 50 25 + 25 + 25 + 25 25 + 25 + 25 + 35 25 + 25 + 25 + 50 25 + 25 + 25 + 60 25 + 25 + 35 + 35 25 + 25 + 35 + 50 25 + 35 + 35 + 35 35 + 35 + 35 + 35 1.95 / 2.35 1.90 / 2.27 1.73 / 2.05 1.52 / 1.78 1.40 / 1.64 1.28 / 1.51 1.87 / 2.20 1.68 / 1.99 1.48 / 1.74 1.36 / 1.60 1.26 / 1.48 1.54 / 1.81 1.36 / 1.60 1.12 / 1.49 1.22 / 1.44 1.78 / 2.14 1.63 / 1.93 1.44 / 1.70 1.33 / 1.57 1.51 / 1.77 1.33 / 1.57 1.24 / 1.46 1.40 / 1.63 1.24 / 1.45 1.98 / 2.35 1.82 / 2.14 1.60 / 1.88 1.48 / 1.74 1.67 / 1.96 1.48 / 1.74 1.55 / 1.81 2.00 / 2.35 1.95 / 2.35 2.15 / 2.59 2.76 / 3.25 3.44 / 4.06 3.81 / 4.48 4.16 / 4.87 2.13 / 2.50 1.91 / 3.16 3.36 / 3.95 3.73 / 4.37 4.05 / 4.76 2.46 / 2.89 3.10 / 3.65 3.84 / 4.05 2.78 / 3.26 2.04 / 2.42 2.60 / 3.07 3.28 / 3.85 3.64 / 4.27 2.39 / 2.81 3.03 / 3.56 3.38 / 3.97 2.20 / 2.59 2.82 / 3.31 1.98 / 2.35 2.54 / 2.98 3.20 / 3.76 3.56 / 4.18 2.33 / 2.74 2.96 / 3.48 2.15 / 2.53 2.00 / 2.35

2 ROOMS
22 + 22 22 + 25 22 + 35 22 + 50 22 + 60 22 + 71 25 + 25 25 + 35 25 + 50 25 + 60 25 + 71 35 + 35 35 + 50 35 + 60 35 + 71 50 + 50 50 + 60 50 + 71 60 + 60 60 + 71 71 + 71 2.20 / 3.30 2.20 / 3.23 2.20 / 2.82 2.20 / 2.72 2.08 / 2.52 1.86 / 2.22 2.50 / 3.60 2.50 / 3.17 2.50 / 3.00 2.28 / 2.94 2.04 / 2.60 3.50 / 4.00 3.19 / 4.12 2.89 / 3.68 2.62 / 3.30 3.95 / 5.00 3.64 / 4.55 3.43 / 4.13 4.15 / 5.00 3.89 / 4.58 4.40 / 5.00

3 ROOMS
22 + 22 + 22 22 + 22 + 25 22 + 22 + 35 22 + 22 + 50 22 + 22 + 60 22 + 22 + 71 22 + 25 + 25 22 + 25 + 35 2.20 / 2.90 2.20 / 2.80 2.14 / 2.78 1.84 / 2.57 1.68 / 2.33 1.53 / 2.10 2.20 / 2.72 2.08 / 2.68 1.79 / 2.49 1.64 / 2.26 1.49 / 2.05 1.87 / 2.40 1.63 / 2.26 1.50 / 2.07 1.46 / 1.89 1.50 / 1.98 1.42 / 1.83 1.38 / 1.69 1.40 / 1.70 1.29 / 1.58 2.20 / 2.90 2.20 / 2.81 2.14 / 2.78 1.84 / 2.57 1.68 / 2.33 1.53 / 2.10 2.50 / 3.09 2.36 / 3.05 2.04 / 2.84 1.87 / 2.57 1.69 / 2.33 2.99 / 3.80 2.58 / 3.60 2.40 / 3.29 2.32 / 3.01 3.40 / 4.51 3.22 / 4.17 3.15 / 3.85 3.80 / 4.65 3.53 / 4.31 2.20 / 2.90 2.50 / 3.19 3.42 / 4.44 4.17 / 5.86 4.59 / 6.35 4.94 / 6.80 2.50 / 3.09 3.31 / 4.27 4.07 / 5.67 4.49 / 6.17 4.82 / 6.62 2.99 / 3.80 3.69 / 5.14 4.1 / 5.64 4.72 / 6.10 3.40 / 4.51 3.86 / 5.00 4.47 / 5.46 3.80 / 4.65 4.18 / 5.11

MXZ-5A100VA
1 Outdoor Unit
Indoor unit combination

22 + 25 + 50 22 + 25 + 60 22 + 25 + 71 22 + 35 + 35 22 + 35 + 50

Up to 5 Indoor Units
Cooling / Heating Capacity (kW) Unit A Unit B Unit C Unit D

22 + 35 + 60 22 + 35 + 71

1 ROOM
22 25 35 50 60 71 2.20 / 3.30 2.50 / 3.60 3.50 / 4.00 5.00 / 7.20 6.00 / 7.90 7.10 / 8.60

22 + 50 + 50 22 + 50 + 60 22 + 50 + 71 22 + 60 + 60 22 + 60 + 71

Page 42

Indoor unit combination

Cooling / Heating Capacity (kW) Unit A Unit B


2.50 / 3.00 2.28 / 2.82 1.98 / 2.75 1.82 / 2.50 1.71/ 2.27 2.89 / 3.68 2.54 / 3.50 2.42 / 3.21 2.27 / 2.94 3.40 / 4.40 3.15 / 4.07 3.08 / 3.77 3.72 / 4.55 3.54 / 4.23 2.65 / 3.33 2.42 / 3.21 2.29 / 2.96 2.16 / 2.73 3.19 / 4.07 3.10 / 3.79 2.95 / 3.53 3.56 / 4.26 3.36 / 3.98 3.07 / 3.67 2.91 / 3.44 2.78 / 3.22

Indoor unit combination

Cooling / Heating Capacity (kW) Unit A Unit B


1.32 / 1.61 1.37 / 1.68 1.29 / 1.57 1.24 / 1.47 2.04 / 2.58 1.86 / 2.34 1.70 / 2.25 1.61 / 2.08 1.57 / 1.92 1.77 / 2.35 1.61 / 2.08 1.58 / 1.94 1.47 / 1.80 1.53 / 1.87 1.43 / 1.75 1.38 / 1.64 2.34 / 3.03 2.22 / 2.71 2.07 / 2.53 2.00 / 2.36 2.07 / 2.45 1.98 / 2.50 1.82 / 2.27 1.70 / 2.20 1.59 / 2.04 1.54 / 1.88 1.73 / 2.29 1.67 / 2.04 1.55 / 1.90 1.47 / 1.76 1.50 / 1.83 1.45 / 1.72 1.39 / 1.61 2.29 / 2.96 2.17 / 2.66 2.08 / 2.48 1.96 / 2.32 2.25 / 2.75 2.08 / 2.48 1.97 / 2.33

Unit C
2.50 / 3.00 3.19 / 3.96 3.94 / 5.50 4.36 / 6.00 4.88 / 6.46 2.89 / 3.68 3.64 / 5.00 4.15 / 5.50 4.61 / 5.96 3.40 / 4.40

Unit D
22 + 22 + 35 + 71 22 + 22 + 50 + 50 22 + 22 + 50 + 60 22 + 22 + 50 + 71 22 + 25 + 25 + 25 22 + 25 + 25 + 35 22 + 25 + 25 + 50 22 + 25 + 25 + 60 22 + 25 + 25 + 71 22 + 25 + 35 + 35

Unit C
2.10 / 2.57 3.13 / 3.82 2.92 / 3.57 2.82 / 3.33 2.04 / 2.58 1.86 / 2.34 1.70 / 2.25 1.61 / 2.08 1.57 / 1.92 2.48 / 3.29 2.25 / 2.92 2.22 / 2.71 2.06 / 2.52 3.06 / 3.74 2.87 / 3.50 2.77 / 3.27 2.34 / 3.03 2.22 / 2.71 2.07 / 2.53 2.00 / 2.36 2.96 / 3.50 1.98 / 2.50 1.82 / 2.27 1.70 / 2.20 1.59 / 2.04 1.54 / 1.88 2.42 / 3.21 2.33 / 2.85 2.17 / 2.66 2.06 / 2.47 3.00 / 3.67 2.91 / 3.44 2.78 / 3.22 2.29 / 2.96 2.17 / 2.66 2.08 / 2.48 1.96 / 2.32 2.25 / 2.75 2.08 / 2.48 1.97 / 2.33

Unit D
4.26 / 5.21 3.13 / 3.82 3.50 / 4.29 4.00 / 4.73 2.04 / 2.58 2.60 / 3.27 3.40 / 4.52 3.86 / 5.01 4.48 / 5.47 2.48 / 3.29 3.22 / 4.17 3.80 / 4.65 4.18 / 5.10 3.06 / 3.74 3.44 / 4.21 3.93 / 4.65 2.34 / 3.03 3.17 / 3.88 3.56 / 4.35 4.05 / 4.80 2.96 / 3.51 1.98 / 2.50 2.54 / 3.19 3.40 / 4.40 3.83 / 4.88 4.38 / 5.36 2.42 / 3.21 3.33 / 4.07 3.73 / 4.54 4.20 / 5.01 3.00 / 3.67 3.49 / 4.12 3.94 / 4.56 2.29 / 2.96 3.11 / 3.79 3.11 / 4.27 3.98 / 4.70 2.25 / 2.75 2.96 / 3.56 3.39 / 4.01

25 + 25 + 25 25 + 25 + 35 25 + 25 + 50 25 + 25 + 60 25 + 25 + 71 25 + 35 + 35 25 + 35 + 50 25 + 35 + 60 25 + 35 + 71 25 + 50 + 50 25 + 50 + 60 25 + 50 + 71 25 + 60 + 60 25 + 60 + 71 35 + 35 + 35 35 + 35 + 50 35 + 35 + 60 35 + 35 + 71 35 + 50 + 50 35 + 50 + 60 35 + 50 + 71 35 + 60 + 60 35 + 60 + 71 50 + 50 + 50 50 + 50 + 60 50 + 50 + 71

2.50 / 3.00 2.28 / 2.82 1.98 / 2.75 1.82 / 2.50 1.71 / 2.27 2.07 / 2.64 1.82 / 2.50 1.73 / 2.29 1.62 / 2.10 1.70 / 2.20 1.57 / 2.04 1.54 / 1.88 1.56 / 1.90 1.47 / 1.76 2.65 / 3.33 2.42 / 3.21 2.29 / 2.96 2.16 / 2.73 2.22 / 2.86 2.17 / 2.66 2.06 / 2.46 2.08 / 2.48 1.96 / 2.32 3.06 / 3.66 2.91 / 3.43 2.78 / 3.22

1.32 / 1.61 1.37 / 1.68 1.29 / 1.57 1.24 / 1.47 1.78 / 2.26 1.63 / 2.05 1.50 / 1.98 1.42 / 1.83 1.38 / 1.69 1.57 / 2.07 1.42 / 1.83 1.40 / 1.70 1.29 / 1.58 1.35 / 1.65 1.26 / 1.54 1.22 / 1.44 1.48 / 1.91 1.39 / 1.70 1.30 / 1.59 1.25 / 1.48 1.31 / 1.54 1.98 / 2.50 1.82 / 2.27 1.70 / 2.20 1.59 / 2.04 1.54 / 1.88 1.73 / 2.29 1.67 / 2.04 1.55 / 1.90 1.47 / 1.76 1.50 / 1.83 1.45 / 1.72 1.39 / 1.61 1.63 / 2.12 1.55 / 1.89 1.48 / 1.77 1.40 / 1.66 2.25 / 2.75 2.08 / 2.48 1.97 / 2.33

3.78 / 4.89 22 + 25 + 35 + 50 4.38 / 5.35 22 + 25 + 35 + 60 3.72 / 4.55 4.19 / 5.01 2.65 / 3.33 3.46 / 4.58 3.92 / 5.08 4.38 / 5.54 3.19 / 4.07 3.73 / 4.55 4.19 / 5.01 3.56 / 4.26 3.98 / 4.70 3.07 / 3.67 3.48 / 4.13 3.94 / 4.56 22 + 25 + 35 + 71 22 + 25 + 50 + 50 22 + 25 + 50 + 60 22 + 25 + 50 + 71 22 + 35 + 35 + 35 22 + 35 + 35 + 50 22 + 35 + 35 + 60 22 + 35 + 35 + 71 22 + 35 + 50 + 50 25 + 25 + 25 + 25 25 + 25 + 25 + 35 25 + 25 + 25 + 50 25 + 25 + 25 + 60 25 + 25 + 25 + 71

4 ROOMS
22 + 22 + 22 + 22 22 + 22 + 22 + 25 22 + 22 + 22 + 35 22 + 22 + 22 + 50 22 + 22 + 22 + 60 22 + 22 + 22 + 71 22 + 22 + 25 + 25 22 + 22 + 25 + 35 22 + 22 + 25 + 50 22 + 22 + 25 + 60 22 + 22 + 25 + 71 22 + 22 + 35 + 35 22 + 22 + 35 + 50 22 + 22 + 35 + 60 1.95 / 2.50 1.90 / 2.42 1.73 / 2.18 1.52 / 2.09 1.48 / 1.92 1.40 / 1.77 1.83 / 2.34 1.68 / 2.12 1.52 / 2.03 1.45 / 1.88 1.37 / 1.73 1.54 / 1.93 1.45 / 1.88 1.38 / 1.74 1.95 / 2.50 1.90 / 2.42 1.73 / 2.18 1.52 / 2.09 1.48 / 1.92 1.40 / 1.77 1.84 / 2.34 1.68 / 2.12 1.52 / 2.03 1.45 / 1.88 1.37 / 1.73 1.54 / 1.93 1.45 / 1.88 1.38 / 1.74 1.95 / 2.50 1.90 / 2.42 1.73 / 2.18 1.52 / 2.09 1.48 / 1.92 1.40 / 1.77 2.09 / 2.66 1.91 / 2.40 1.72 / 2.31 1.65 / 2.13 1.55 / 1.96 2.46 / 3.07 2.31 / 2.98 2.19 / 2.77 1.95 / 2.50 2.15 / 2.74

25 + 25 + 35 + 35 25 + 25 + 35 + 50 25 + 25 + 35 + 60 2.76 / 3.46 25 + 25 + 35 + 71 3.44 / 4.73 25 + 25 + 50 + 50 4.06 / 5.24 4.50 / 5.69 2.09 / 2.66 2.68 / 3.36 3.44 / 4.63 3.95 / 5.11 4.41 / 5.58 2.46 / 3.07 3.29 / 4.26 3.75 / 4.75 25 + 25 + 50 + 60 25 + 25 + 50 + 71 25 + 35 + 35 + 35 25 + 35 + 35 + 50 25 + 35 + 35 + 60 25 + 35 + 35 + 71 35 + 35 + 35 + 35 35 + 35 + 35 + 50 35 + 35 + 35 + 60

Page 43

Indoor unit combination Unit A Unit B

Cooling / Heating Capacity (kW) Unit C Unit D Unit E Unit F Unit G Unit H

5 ROOMS
22 + 22 + 22 + 22 + 22 22 + 22 + 22 + 22 + 25 22 + 22 + 22 + 22 + 35 22 + 22 + 22 + 22 + 50 22 + 22 + 22 + 22 + 60 22 + 22 + 22 + 22 + 71 22 + 22 + 22 + 25 + 25 22 + 22 + 22 + 25 + 35 22 + 22 + 22 + 25 + 50 22 + 22 + 22 + 25 + 60 22 + 22 + 22 + 25 + 71 22 + 22 + 22 + 35 + 35 22 + 22 + 22 + 35 + 50 22 + 22 + 22 + 35 + 60 22 + 22 + 22 + 35 + 71 22 + 22 + 25 + 25 + 25 22 + 22 + 25 + 25 + 35 22 + 22 + 25 + 25 + 50 22 + 22 + 25 + 25 + 60 22 + 22 + 25 + 25 + 71 22 + 22 + 25 + 35 + 35 22 + 22 + 25 + 35 + 50 22 + 22 + 35 + 35 + 35 22 + 25 + 25 + 25 + 25 22 + 25 + 25 + 25 + 35 22 + 25 + 25 + 25 + 50 22 + 25 + 25 + 25 + 60 22 + 25 + 25 + 25 + 71 22 + 25 + 25 + 35 + 35 22 + 25 + 25 + 35 + 50 22 + 25 + 25 + 35 + 60 22 + 25 + 35 + 35 + 35 25 + 25 + 25 + 25 + 25 25 + 25 + 25 + 25 + 35 25 + 25 + 25 + 25 + 50 25 + 25 + 25 + 25 + 60 25 + 25 + 25 + 25 + 71 25 + 25 + 25 + 35 + 35 25 + 25 + 35 + 35 + 35 25 + 25 + 35 + 35 + 50 2.00 / 2.40 1.95 / 2.34 1.79 / 2.15 1.59 / 1.91 1.49 / 1.78 1.38 / 1.66 1.90 / 2.28 1.75 / 2.10 1.56 / 1.87 1.46 / 1.75 1.36 / 1.63 1.62 / 1.94 1.46 / 1.75 1.37 / 1.64 1.28 / 1.53 1.85 / 2.22 1.71 / 2.04 1.53 / 1.83 1.43 / 1.71 1.33 / 1.60 1.58 / 1.90 1.43 / 1.71 1.47 / 1.77 1.80 / 2.16 1.67 / 2.00 1.50 / 1.80 1.40 / 1.68 1.30 / 1.57 1.56 / 1.86 1.40 / 1.68 1.31 / 1.58 1.46 / 1.75 2.00 / 2.40 1.85 / 2.22 1.67 / 2.00 1.56 / 1.88 1.46 / 1.75 1.72 / 2.07 1.61 / 1.94 1.47 / 1.76 2.00 / 2.40 1.95 / 2.34 1.79 / 2.15 1.59 / 1.91 1.49 / 1.78 1.38 / 1.66 1.90 / 2.28 1.75 / 2.10 1.56 / 1.87 1.46 / 1.75 1.36 / 1.63 1.62 / 1.94 1.46 / 1.75 1.37 / 1.64 1.28 / 1.53 1.85 / 2.22 1.71 / 2.04 1.53 / 1.83 1.43 / 1.71 1.33 / 1.60 1.58 / 1.90 1.43 / 1.71 1.48 / 1.77 2.05 / 2.46 1.89 / 2.27 1.70 / 2.04 1.59 / 1.91 1.49 / 1.79 1.76 / 2.11 1.59 / 1.91 1.50 / 1.80 1.64 / 1.97 2.00 / 2.40 1.85 / 2.22 1.67 / 2.00 1.56 / 1.88 1.46 / 1.75 1.72 / 2.07 1.61 / 1.94 1.47 / 1.76 2.00 / 2.40 1.95 / 2.34 1.79 / 2.15 1.59 / 1.91 1.49 / 1.78 1.38 / 1.66 1.90 / 2.28 1.75 / 2.10 1.56 / 1.87 1.46 / 1.75 1.36 / 1.63 1.62 / 1.94 1.46 / 1.75 1.37 / 1.64 1.28 / 1.53 2.10 / 2.52 1.94 / 2.33 1.74 / 2.08 1.62 / 1.95 1.52 / 1.82 1.80 / 2.16 1.62 / 1.95 2.35 / 2.82 2.05 / 2.46 1.89 / 2.27 1.70 / 2.04 1.59 / 1.91 1.49 / 1.79 1.76 / 2.11 1.59 / 1.91 1.50 / 1.80 2.30 / 2.76 2.00 / 2.40 1.85 / 2.22 1.67 / 2.00 1.56 / 1.88 1.46 / 1.75 1.72 / 2.07 2.26 / 2.71 2.06 / 2.47 2.00 / 2.40 1.95 / 2.34 1.79 / 2.15 1.59 / 1.91 1.49 / 1.78 1.38 / 1.66 2.15 / 2.58 1.97 / 2.38 1.77 / 2.13 1.66 / 1.99 1.54 / 1.85 2.57 / 3.09 2.32 / 2.78 2.17 / 2.61 2.03 / 2.44 2.10 / 2.52 1.94 / 2.33 1.74 / 2.08 1.62 / 1.95 1.52 / 1.82 2.52 / 3.02 2.27 / 2.73 2.35 / 2.82 2.05 / 2.46 1.89 / 2.27 1.70 / 2.04 1.59 / 1.91 1.49 / 1.79 2.46 / 2.96 2.23 / 2.68 2.10 / 2.51 2.30 / 2.76 2.00 / 2.40 1.85 / 2.22 1.67 / 2.00 1.56 / 1.88 1.46 / 1.75 2.42 / 2.90 2.26 / 2.71 2.06 / 2.47 2.00 / 2.40 2.20 / 2.65 2.84 / 3.40 3.64 / 4.36 4.04 / 4.88 4.48 / 5.36 2.15 / 2.58 2.78 / 3.32 3.55 / 4.26 3.96 / 4.76 4.38 / 5.26 2.57 / 3.09 3.30 / 3.97 3.72 / 4.47 4.13 / 4.95 2.10 / 2.52 2.70 / 3.26 3.46 / 4.18 3.90 / 4.68 4.30 / 5.16 2.52 / 3.02 3.25 / 3.90 2.35 / 2.82 2.05 / 2.46 2.66 / 3.19 3.40 / 4.08 3.83 / 4.59 4.23 / 5.07 2.46 / 2.96 3.19 / 3.82 3.59 / 4.31 2.30 / 2.76 2.00 / 2.40 2.60 / 3.12 3.32 / 4.00 3.76 / 4.50 4.16 / 4.98 2.42 / 2.90 2.26 / 2.71 2.94 / 3.54

Page 44

MXZ-8A140VA
1 Outdoor Unit
Indoor unit combination

Up to 8 Indoor Units
Cooling / Heating Capacity (kW) Unit A Unit B Unit C Unit D

Indoor unit combination

Cooling / Heating Capacity (kW) Unit A Unit B


2.50 / 2.86 2.50 / 2.85 2.50 / 2.86 3.50 / 3.99 3.50 / 3.99 3.50 / 4.01 3.50 / 3.99 5.00 / 5.70 5.00 / 5.72 4.90 / 5.59 5.92 / 6.76 5.49 / 6.27 6.06 / 6.93 2.50 / 2.86 2.50 / 2.85 2.50 / 2.85 2.50 / 2.86 2.50 / 2.85 3.50 / 4.02 3.50 / 4.01 3.50 / 4.00 3.50 / 4.01 5.00 / 5.72 5.00 / 5.70 4.79 / 5.48 5.79 / 6.62 5.38 / 6.15 5.95 / 6.80 3.50 / 4.00 3.50 / 4.00 3.50 / 4.01 3.48 / 3.97 5.00 / 5.70 4.83 / 5.52 4.49 / 5.13 5.42 / 6.19 5.06 / 5.78 5.62 / 6.42 4.67 / 5.33 4.38 / 5.00 4.09 / 4.68 4.94 / 5.65 4.64 / 5.30 4.67 / 5.33

Unit C
5.00 / 5.72 6.00 / 6.84 7.10 / 8.12 3.50 / 3.99 5.00 / 5.70 6.00 / 6.87 7.10 / 8.10 5.00 / 5.70 6.00 / 6.86 6.95 / 7.94 5.92 / 6.76 6.50 / 7.42 6.06 / 6.93 2.50 / 2.86 3.50 / 3.99 5.00 / 5.70 6.00 / 6.87 7.10 / 8.10 3.50 / 4.02 5.00 / 5.73 6.00 / 6.85 7.10 / 8.13 5.00 / 5.72 6.00 / 6.84 6.81 / 7.78 5.79 / 6.62 6.37 / 7.28 5.95 / 6.80 3.50 / 4.00 5.00 / 5.70 6.00 / 6.88 7.05 / 8.06 5.00 / 5.70 5.79 / 6.62 6.37 / 7.28 5.42 / 6.19 5.99 / 6.84 5.62 / 6.42 4.67 / 5.33 5.25 / 6.00 5.81 / 6.64 4.94 / 5.65 5.49 / 6.28 4.67 / 5.33

Unit D

22 + 25 + 50 22 + 25 + 60 22 + 25 + 71 22 + 35 + 35

2.20 / 2.52 2.20 / 2.51 2.20 / 2.52 2.20 / 2.51 2.20 / 2.51 2.20 / 2.52 2.20 / 2.51 2.20 / 2.50 2.20 / 2.52 2.15 / 2.46 2.17 / 2.48 2.01 / 2.30 1.88 / 2.14 2.50 / 2.86 2.50 / 2.85 2.50 / 2.85 2.50 / 2.86 2.50 / 2.85 2.50 / 2.86 2.50 / 2.86 2.50 / 2.85 2.50 / 2.86 2.50 / 2.86 2.50 / 2.85 2.40 / 2.74 2.41 / 2.76 2.24 / 2.56 2.10 / 2.40 3.50 / 4.00 3.50 / 4.00 3.50 / 4.01 3.48 / 3.97 3.50 / 3.99 3.38 / 3.86 3.14 / 3.59 3.16 / 3.61 2.95 / 3.37 2.77 / 3.16 4.67 / 5.33 4.38 / 5.00 4.09 / 4.68 4.12 / 4.70 3.87 / 4.42 4.67 / 5.33

1 ROOM
22 25 35 50 60 71 2.20 / 3.30 2.50 / 3.60 3.50 / 4.00 5.00 / 7.20 6.00 / 7.90 7.10 / 8.60

22 + 35 + 50 22 + 35 + 60 22 + 35 + 71 22 + 50 + 50 22 + 50 + 60 22 + 50 + 71 22 + 60 + 60 22 + 60 + 71

2 ROOMS
22 + 22 22 + 25 22 + 35 22 + 50 22 + 60 22 + 71 25 + 25 25 + 35 25 + 50 25 + 60 25 + 71 35 + 35 35 + 50 35 + 60 35 + 71 50 + 50 50 + 60 50 + 71 60 + 60 60 + 71 71 + 71 2.20 / 2.50 2.20 / 2.53 2.20 / 2.51 2.20 / 2.51 2.20 / 2.52 2.20 / 2.51 2.50 / 2.85 2.50 / 2.88 2.50 / 2.87 2.50 / 2.85 2.50 / 2.86 3.50 / 4.00 3.50 / 3.99 3.50 / 4.02 3.50 / 4.00 5.00 / 5.70 5.00 / 5.73 5.00 / 5.70 6.00 / 6.85 6.00 / 6.87 7.00 / 8.00 2.20 / 2.50 2.50 / 2.87

22 + 71 + 71 25 + 25 + 25 25 + 25 + 35 3.50 / 3.99 25 + 25 + 50 5.00 / 5.69 25 + 25 + 60 6.00 / 6.88 25 + 25 + 71 7.10 / 8.09 25 + 35 + 35 2.50 / 2.85 3.50 / 4.02 5.00 / 5.73 6.00 / 6.85 7.10 / 8.14 3.50 / 4.00 5.00 / 5.71 6.00 / 6.88 7.10 / 8.10 5.00 / 5.70 6.00 / 6.87 7.10 / 8.10 6.00 / 6.85 7.10 / 8.13 7.00 / 8.00 25 + 35 + 50 25 + 35 + 60 25 + 35 + 71 25 + 50 + 50 25 + 50 + 60 25 + 50 + 71 25 + 60 + 60 25 + 60 + 71 25 + 71 + 71 35 + 35 + 35 35 + 35 + 50 35 + 35 + 60 35 + 35 + 71 35 + 50 + 50 35 + 50 + 60 35 + 50 + 71

3 ROOMS
22 + 22 + 22 22 + 22 + 25 22 + 22 + 35 22 + 22 + 50 22 + 22 + 60 22 + 22 + 71 22 + 25 + 25 22 + 25 + 35 2.20 / 2.50 2.20 / 2.52 2.20 / 2.51 2.20 / 2.50 2.20 / 2.52 2.20 / 2.51 2.20 / 2.50 2.20 / 2.52 2.20 / 2.50 2.20 / 2.52 2.20 / 2.51 2.20 / 2.50 2.20 / 2.52 2.20 / 2.51 2.50 / 2.85 2.50 / 2.87 2.20 / 2.50 2.50 / 2.86 3.50 / 3.98 5.00 / 5.69 6.00 / 6.86 7.10 / 8.09 2.50 / 2.85 3.50 / 4.01

35 + 60 + 60 35 + 60 + 71 35 + 71 + 71 50 + 50 + 50 50 + 50 + 60 50 + 50 + 71 50 + 60 + 60 50 + 60 + 71 60 + 60 + 60

Page 45

Indoor unit combination

Cooling / Heating Capacity (kW) Unit A Unit B Unit C Unit D

Indoor unit combination

Cooling / Heating Capacity (kW) Unit A Unit B


3.22 / 3.68 3.01 / 3.44 3.12 / 3.57 2.93 / 3.35 2.75 / 3.15 2.77 / 3.16 4.07 / 4.65 3.85 / 4.40 2.50 / 2.85 2.50 / 2.86 2.50 / 2.86 2.50 / 2.85 2.40 / 2.74 2.50 / 2.85 2.50 / 2.85 2.41 / 2.76 2.24 / 2.56 2.33 / 2.67 2.19 / 2.50 2.05 / 2.34 2.06 / 2.35 1.93 / 2.21 3.50 / 4.01 3.38 / 3.86 3.16 / 3.61 2.95 / 3.37 3.06 / 3.50 2.88 / 3.29 2.71 / 3.09 2.72 / 3.11 4.00 / 4.57 3.78 / 4.32 3.50 / 4.00 3.16 / 3.61 2.97 / 3.39 2.78 / 3.18 2.88 / 3.29 2.72 / 3.11 3.78 / 4.32

Unit C
3.22 / 3.68 3.01 / 3.44 4.46 / 5.10 4.19 / 4.79 3.93 / 4.49 4.75 / 5.42 4.07 / 4.65 3.85 / 4.40 2.50 / 2.85 2.50 / 2.86 2.50 / 2.86 2.50 / 2.85 2.40 / 2.74 3.50 / 4.00 3.50 / 3.99 3.38 / 3.86 3.14 / 3.59 4.67 / 5.33 4.38 / 5.00 4.09 / 4.68 4.94 / 5.65 4.64 / 5.30 3.50 / 4.01 3.38 / 3.86 3.16 / 3.61 2.95 / 3.37 4.38 / 5.00 4.12 / 4.71 3.87 / 4.42 4.67 / 5.33 4.00 / 4.57 3.78 / 4.32 3.50 / 4.00 3.16 / 3.61 2.97 / 3.39 2.78 / 3.18 4.12 / 4.71 3.89 / 4.44 3.78 / 4.32

Unit D
5.53 / 6.32 6.09 / 6.96 4.46 / 5.10 5.03 / 5.75 5.58 / 6.38 4.75 / 5.42 4.07 / 4.65 4.61 / 5.27 2.50 / 2.85 3.50 / 4.01 5.00 / 5.72 6.00 / 6.84 6.80 / 7.78 3.50 / 4.00 5.00 / 5.70 5.79 / 6.62 6.37 / 7.28 4.67 / 5.33 5.24 / 6.00 5.81 / 6.64 4.94 / 5.65 5.49 / 6.28 3.50 / 4.01 4.83 / 5.52 5.42 / 6.19 5.99 / 6.84 4.38 / 5.00 4.94 / 5.65 5.49 / 6.28 4.67 / 5.33 4.00 / 4.57 4.54 / 5.19 3.50 / 4.00 4.52 / 5.16 5.09 / 5.82 5.65 / 6.45 4.12 / 4.71 4.67 / 5.33 3.78 / 4.32

4 ROOMS
22 + 22 + 22 + 22 22 + 22 + 22 + 25 22 + 22 + 22 + 35 22 + 22 + 22 + 50 22 + 22 + 22 + 60 22 + 22 + 22 + 71 22 + 22 + 25 + 25 22 + 22 + 25 + 35 22 + 22 + 25 + 50 22 + 22 + 25 + 60 22 + 22 + 25 + 71 22 + 22 + 35 + 35 22 + 22 + 35 + 50 22 + 22 + 35 + 60 22 + 22 + 35 + 71 22 + 22 + 50 + 50 22 + 22 + 50 + 60 22 + 22 + 50 + 71 22 + 22 + 60 + 60 22 + 22 + 60 + 71 22 + 25 + 25 + 25 22 + 25 + 25 + 35 22 + 25 + 25 + 50 22 + 25 + 25 + 60 22 + 25 + 25 + 71 22 + 25 + 35 + 35 22 + 25 + 35 + 50 22 + 25 + 35 + 60 22 + 25 + 35 + 71 22 + 25 + 50 + 50 22 + 25 + 50 + 60 22 + 25 + 50 + 71 22 + 25 + 60 + 60 22 + 25 + 60 + 71 22 + 35 + 35 + 35 22 + 35 + 35 + 50 2.20 / 2.52 2.20 / 2.51 2.20 / 2.50 2.20 / 2.52 2.20 / 2.51 2.20 / 2.52 2.20 / 2.50 2.20 / 2.52 2.20 / 2.51 2.20 / 2.51 2.20 / 2.51 2.20 / 2.51 2.20 / 2.51 2.20 / 2.52 2.05 / 2.35 2.14 / 2.44 2.00 / 2.29 1.87 / 2.13 1.88 / 2.15 1.76 / 2.01 2.20 / 2.52 2.20 / 2.51 2.20 / 2.51 2.20 / 2.52 2.15 / 2.46 2.20 / 2.52 2.20 / 2.52 2.17 / 2.48 2.01 / 2.30 2.10 / 2.39 1.96 / 2.24 1.83 / 2.10 1.84 / 2.10 1.73 / 1.98 2.20 / 2.50 2.17 / 2.48 2.20 / 2.52 2.20 / 2.51 2.20 / 2.50 2.20 / 2.52 2.20 / 2.51 2.20 / 2.52 2.20 / 2.50 2.20 / 2.52 2.20 / 2.51 2.20 / 2.51 2.20 / 2.51 2.20 / 2.51 2.20 / 2.51 2.20 / 2.52 2.05 / 2.35 2.14 / 2.44 2.00 / 2.29 1.87 / 2.13 1.88 / 2.15 1.76 / 2.01 2.50 / 2.86 2.50 / 2.85 2.50 / 2.85 2.50 / 2.86 2.45 / 2.80 2.50 / 2.86 2.50 / 2.86 2.46 / 2.82 2.29 / 2.61 2.38 / 2.72 2.23 / 2.55 2.08 / 2.38 2.10 / 2.40 1.97 / 2.25 3.50 / 4.00 3.45 / 3.94 2.20 / 2.52 2.20 / 2.51 2.20 / 2.50 2.20 / 2.52 2.20 / 2.51 2.20 / 2.52 2.50 / 2.85 2.50 / 2.86 2.50 / 2.86 2.50 / 2.85 2.50 / 2.86 3.50 / 3.99 3.50 / 3.99 3.50 / 4.00 3.27 / 3.73 4.86 / 5.56 4.55 / 5.19 4.24 / 4.85 5.12 / 5.85 4.80 / 5.49 2.50 / 2.86 2.50 / 2.85 2.50 / 2.85 2.50 / 2.86 2.45 / 2.80 3.50 / 4.01 3.50 / 4.00 3.45 / 3.94 3.20 / 3.66 4.76 / 5.44 4.46 / 5.10 4.17 / 4.76 5.03 / 5.75 4.72 / 5.39 3.50 / 4.00 3.45 / 3.94 2.20 / 2.52 2.50 / 2.86 3.50 / 3.99 5.00 / 5.73 6.00 / 6.86 7.10 / 8.14 2.50 / 2.85 3.50 / 4.00 5.00 / 5.71 6.00 / 6.83

22 + 35 + 35 + 60 22 + 35 + 35 + 71 22 + 35 + 50 + 50 22 + 35 + 50 + 60 22 + 35 + 50 + 71 22 + 35 + 60 + 60 22 + 50 + 50 + 50 22 + 50 + 50 + 60 25 + 25 + 25 + 25 25 + 25 + 25 + 35 25 + 25 + 25 + 50 25 + 25 + 25 + 60 7.10 / 8.11 25 + 25 + 25 + 71 3.50 / 3.99 25 + 25 + 35 + 35 5.00 / 5.69 25 + 25 + 35 + 50 6.00 / 6.86 6.63 / 7.57 4.86 / 5.56 5.45 / 6.23 6.02 / 6.88 5.12 / 5.85 5.68 / 6.49 2.50 / 2.86 3.50 / 3.99 5.00 / 5.69 6.00 / 6.86 6.95 / 7.94 3.50 / 4.01 25 + 35 + 50 + 71 5.00 / 5.72 25 + 35 + 60 + 60 5.92 / 6.76 25 + 50 + 50 + 50 6.50 / 7.42 25 + 50 + 50 + 60 4.76 / 5.44 5.35 / 6.11 5.92 / 6.76 5.03 / 5.75 5.58 / 6.38 3.50 / 4.00 4.93 / 5.63 35 + 35 + 35 + 35 35 + 35 + 35 + 50 35 + 35 + 35 + 60 35 + 35 + 35 + 71 35 + 35 + 50 + 50 35 + 35 + 50 + 60 35 + 50 + 50 + 50 25 + 25 + 35 + 60 25 + 25 + 35 + 71 25 + 25 + 50 + 50 25 + 25 + 50 + 60 25 + 25 + 50 + 71 25 + 25 + 60 + 60 25 + 25 + 60 + 71 25 + 35 + 35 + 35 25 + 35 + 35 + 50 25 + 35 + 35 + 60 25 + 35 + 35 + 71 25 + 35 + 50 + 50 25 + 35 + 50 + 60

2.03 / 2.32 1.89 / 2.16 1.96 / 2.23 1.84 / 2.11 1.73 / 1.98 1.73 / 1.99 1.79 / 2.05 1.69 / 1.93 2.50 / 2.85 2.50 / 2.86 2.50 / 2.86 2.50 / 2.85 2.40 / 2.74 2.50 / 2.85 2.50 / 2.85 2.41 / 2.76 2.24 / 2.56 2.33 / 2.67 2.19 / 2.50 2.05 / 2.34 2.06 / 2.35 1.93 / 2.21 2.50 / 2.87 2.41 / 2.76 2.26 / 2.58 2.11 / 2.41 2.18 / 2.50 2.06 / 2.35 1.93 / 2.21 1.94 / 2.22 2.00 / 2.29 1.89 / 2.16 3.50 / 4.00 3.16 / 3.61 2.97 / 3.39 2.78 / 3.18 2.88 / 3.29 2.72 / 3.11 2.65 / 3.03

Page 46

Indoor unit combination Unit A Unit B

Cooling / Heating Capacity (kW) Unit C Unit D Unit E Unit F Unit G Unit H

5 ROOMS
22 + 22 + 22 + 22 + 22 22 + 22 + 22 + 22 + 25 22 + 22 + 22 + 22 + 35 22 + 22 + 22 + 22 + 50 22 + 22 + 22 + 22 + 60 22 + 22 + 22 + 22 + 71 22 + 22 + 22 + 25 + 25 22 + 22 + 22 + 25 + 35 22 + 22 + 22 + 25 + 50 22 + 22 + 22 + 25 + 60 22 + 22 + 22 + 25 + 71 22 + 22 + 22 + 35 + 35 22 + 22 + 22 + 35 + 50 22 + 22 + 22 + 35 + 60 22 + 22 + 22 + 35 + 71 22 + 22 + 22 + 50 + 50 22 + 22 + 22 + 50 + 60 22 + 22 + 25 + 25 + 25 22 + 22 + 25 + 25 + 35 22 + 22 + 25 + 25 + 50 22 + 22 + 25 + 25 + 60 22 + 22 + 25 + 25 + 71 22 + 22 + 25 + 35 + 35 22 + 22 + 25 + 35 + 50 22 + 22 + 25 + 35 + 60 22 + 22 + 25 + 35 + 71 22 + 22 + 25 + 50 + 50 22 + 22 + 25 + 50 + 60 22 + 22 + 35 + 35 + 35 22 + 22 + 35 + 35 + 50 22 + 22 + 35 + 35 + 60 22 + 22 + 35 + 35 + 71 22 + 22 + 35 + 50 + 50 22 + 25 + 25 + 25 + 25 22 + 25 + 25 + 25 + 35 22 + 25 + 25 + 25 + 50 22 + 25 + 25 + 25 + 60 22 + 25 + 25 + 25 + 71 22 + 25 + 25 + 35 + 35 22 + 25 + 25 + 35 + 50 22 + 25 + 25 + 35 + 60 22 + 25 + 25 + 35 + 71 22 + 25 + 25 + 50 + 50 22 + 25 + 25 + 50 + 60 22 + 25 + 35 + 35 + 35 22 + 25 + 35 + 35 + 50 22 + 25 + 35 + 35 + 60 22 + 25 + 35 + 50 + 50 22 + 35 + 35 + 35 + 35 22 + 35 + 35 + 35 + 50 2.20 / 2.52 2.20 / 2.51 2.20 / 2.52 2.20 / 2.52 2.08 / 2.38 1.94 / 2.21 2.20 / 2.52 2.20 / 2.51 2.18 / 2.50 2.04 / 2.33 1.90 / 2.17 2.20 / 2.51 2.04 / 2.33 1.91 / 2.19 1.79 / 2.05 1.86 / 2.12 1.75 / 2.00 2.20 / 2.51 2.20 / 2.51 2.14 / 2.44 2.00 / 2.29 1.87 / 2.13 2.20 / 2.52 2.00 / 2.29 1.88 / 2.15 1.76 / 2.01 1.82 / 2.08 1.72 / 1.97 2.06 / 2.36 1.88 / 2.15 1.77 / 2.02 1.66 / 1.90 1.72 / 1.97 2.20 / 2.50 2.20 / 2.52 2.10 / 2.39 1.96 / 2.24 1.83 / 2.10 2.17 / 2.48 1.96 / 2.24 1.84 / 2.11 1.73 / 1.98 1.79 / 2.04 1.69 / 1.93 2.03 / 2.32 1.84 / 2.11 1.74 / 1.99 1.69 / 1.92 1.90 / 2.16 1.74 / 1.99 2.20 / 2.52 2.20 / 2.51 2.20 / 2.52 2.20 / 2.52 2.08 / 2.38 1.94 / 2.21 2.20 / 2.52 2.20 / 2.51 2.18 / 2.50 2.04 / 2.33 1.90 / 2.17 2.20 / 2.51 2.04 / 2.33 1.91 / 2.19 1.79 / 2.05 1.86 / 2.12 1.75 / 2.00 2.20 / 2.51 2.20 / 2.51 2.14 / 2.44 2.00 / 2.29 1.87 / 2.13 2.20 / 2.52 2.00 / 2.29 1.88 / 2.15 1.76 / 2.01 1.82 / 2.08 1.72 / 1.97 2.06 / 2.36 1.88 / 2.15 1.77 / 2.02 1.66 / 1.90 1.72 / 1.97 2.50 / 2.85 2.50 / 2.86 2.38 / 2.72 2.23 / 2.55 2.08 / 2.38 2.46 / 2.82 2.23 / 2.55 2.10 / 2.40 1.97 / 2.25 2.03 / 2.33 1.92 / 2.20 2.30 / 2.63 2.10 / 2.40 1.98 / 2.26 1.92 / 2.20 3.02 / 3.46 2.77 / 3.16 2.20 / 2.52 2.20 / 2.51 2.20 / 2.52 2.20 / 2.52 2.08 / 2.38 1.94 / 2.21 2.20 / 2.52 2.20 / 2.51 2.18 / 2.50 2.04 / 2.33 1.90 / 2.17 2.20 / 2.51 2.04 / 2.33 1.91 / 2.19 1.79 / 2.05 1.86 / 2.12 1.75 / 2.00 2.50 / 2.86 2.50 / 2.85 2.43 / 2.78 2.27 / 2.60 2.12 / 2.42 2.50 / 2.86 2.27 / 2.60 2.13 / 2.44 2.00 / 2.29 2.07 / 2.37 1.96 / 2.23 3.29 / 3.76 2.99 / 3.41 2.82 / 3.22 2.65 / 3.03 2.74 / 3.12 2.50 / 2.85 2.50 / 2.86 2.38 / 2.72 2.23 / 2.55 2.08 / 2.38 2.46 / 2.82 2.23 / 2.55 2.10 / 2.40 1.97 / 2.25 2.03 / 2.33 1.92 / 2.20 3.22 / 3.68 2.93 / 3.35 2.77 / 3.16 2.69 / 3.08 3.02 / 3.46 2.77 / 3.16 2.20 / 2.52 2.20 / 2.51 2.20 / 2.52 2.20 / 2.52 2.08 / 2.38 1.94 / 2.21 2.50 / 2.87 2.50 / 2.86 2.48 / 2.84 2.32 / 2.65 2.16 / 2.47 3.50 / 3.98 3.25 / 3.71 3.04 / 3.48 2.85 / 3.26 4.21 / 4.82 3.98 / 4.55 2.50 / 2.86 2.50 / 2.85 2.43 / 2.78 2.27 / 2.60 2.12 / 2.42 3.50 / 4.00 3.18 / 3.64 2.99 / 3.41 2.80 / 3.20 4.14 / 4.73 3.91 / 4.47 3.29 / 3.76 2.99 / 3.41 2.82 / 3.22 2.65 / 3.03 3.91 / 4.47 2.50 / 2.85 2.50 / 2.86 2.38 / 2.72 2.23 / 2.55 2.08 / 2.38 3.45 / 3.94 3.12 / 3.57 2.93 / 3.35 2.75 / 3.15 4.07 / 4.65 3.85 / 4.40 3.22 / 3.68 2.93 / 3.35 2.77 / 3.16 3.85 / 4.40 3.02 / 3.46 2.77 / 3.16 2.20 / 2.52 2.50 / 2.85 3.50 / 4.01 5.00 / 5.72 5.68 / 6.48 6.24 / 7.14 2.50 / 2.87 3.50 / 4.00 4.96 / 5.66 5.56 / 6.36 6.14 / 7.01 3.50 / 3.98 4.63 / 5.30 5.22 / 5.95 5.78 / 6.59 4.21 / 4.82 4.77 / 5.45 2.50 / 2.86 3.50 / 3.98 4.86 / 5.56 5.45 / 6.22 6.02 / 6.88 3.50 / 4.00 4.55 / 5.18 5.12 / 5.85 5.68 / 6.49 4.14 / 4.73 4.69 / 5.36 3.29 / 3.76 4.26 / 4.88 4.82 / 5.52 5.37 / 6.14 3.91 / 4.47 2.50 / 2.85 3.50 / 4.00 4.76 / 5.44 5.35 / 6.11 5.92 / 6.76 3.45 / 3.94 4.46 / 5.09 5.03 / 5.74 5.58 / 6.37 4.07 / 4.65 4.62 / 5.27 3.22 / 3.68 4.19 / 4.79 4.74 / 5.42 3.85 / 4.40 3.02 / 3.46 3.95 / 4.52

Page 47

Indoor unit combination Unit A


25 + 25 + 25 + 25 + 25 25 + 25 + 25 + 25 + 35 25 + 25 + 25 + 25 + 50 25 + 25 + 25 + 25 + 60 25 + 25 + 25 + 25 + 71 25 + 25 + 25 + 35 + 35 25 + 25 + 25 + 35 + 50 25 + 25 + 25 + 35 + 60 25 + 25 + 25 + 35 + 71 25 + 25 + 25 + 50 + 50 25 + 25 + 25 + 50 + 60 25 + 25 + 35 + 35 + 35 25 + 25 + 35 + 35 + 50 25 + 25 + 35 + 35 + 60 25 + 25 + 35 + 50 + 50 25 + 35 + 35 + 35 + 35 25 + 35 + 35 + 35 + 50 35 + 35 + 35 + 35 + 35 2.50 / 2.86 2.50 / 2.85 2.33 / 2.67 2.19 / 2.50 2.05 / 2.34 2.41 / 2.76 2.19 / 2.50 2.06 / 2.35 1.93 / 2.21 2.00 / 2.29 1.89 / 2.16 2.26 / 2.58 2.06 / 2.35 1.94 / 2.22 1.89 / 2.16 2.12 / 2.42 1.94 / 2.22 2.80 / 3.20

Cooling / Heating Capacity (kW) Unit B


2.50 / 2.86 2.50 / 2.85 2.33 / 2.67 2.19 / 2.50 2.05 / 2.34 2.41 / 2.76 2.19 / 2.50 2.06 / 2.35 1.93 / 2.21 2.00 / 2.29 1.89 / 2.16 2.26 / 2.58 2.06 / 2.35 1.94 / 2.22 1.89 / 2.16 2.97 / 3.39 2.72 / 3.11 2.80 / 3.20

Unit C
2.50 / 2.86 2.50 / 2.85 2.33 / 2.67 2.19 / 2.50 2.05 / 2.34 2.41 / 2.76 2.19 / 2.50 2.06 / 2.35 1.93 / 2.21 2.00 / 2.29 1.89 / 2.16 3.16 / 3.61 2.88 / 3.29 2.72 / 3.11 2.65 / 3.03 2.97 / 3.39 2.72 / 3.11 2.80 / 3.20

Unit D
2.50 / 2.86 2.50 / 2.85 2.33 / 2.67 2.19 / 2.50 2.05 / 2.34 3.38 / 3.86 3.06 / 3.50 2.88 / 3.29 2.71 / 3.09 4.00 / 4.56 3.78 / 4.32 3.16 / 3.61 2.88 / 3.29 2.72 / 3.11 3.78 / 4.32 2.97 / 3.39 2.72 / 3.11 2.80 / 3.20

Unit E
2.50 / 2.86 3.50 / 3.99 4.67 / 5.32 5.24 / 6.00 5.80 / 6.64 3.38 / 3.86 4.37 / 5.00 4.94 / 5.65 5.49 / 6.28 4.00 / 4.56 4.54 / 5.19 3.16 / 3.61 4.12 / 4.71 4.67 / 5.33 3.78 / 4.32 2.97 / 3.39 3.89 / 4.44 2.80 / 3.20

Unit F

Unit G

Unit H

6 ROOMS
22 + 22 + 22 + 22 + 22 + 22 22 + 22 + 22 + 22 + 22 + 25 22 + 22 + 22 + 22 + 22 + 35 22 + 22 + 22 + 22 + 22 + 50 22 + 22 + 22 + 22 + 22 + 60 22 + 22 + 22 + 22 + 22 + 71 22 + 22 + 22 + 22 + 25 + 25 22 + 22 + 22 + 22 + 25 + 35 22 + 22 + 22 + 22 + 25 + 50 22 + 22 + 22 + 22 + 25 + 60 22 + 22 + 22 + 22 + 25 + 71 22 + 22 + 22 + 22 + 35 + 35 22 + 22 + 22 + 22 + 35 + 50 22 + 22 + 22 + 22 + 35 + 60 22 + 22 + 22 + 25 + 25 + 25 22 + 22 + 22 + 25 + 25 + 35 22 + 22 + 22 + 25 + 25 + 50 22 + 22 + 22 + 25 + 25 + 60 22 + 22 + 22 + 25 + 35 + 35 22 + 22 + 22 + 25 + 35 + 50 22 + 22 + 22 + 35 + 35 + 35 22 + 22 + 25 + 25 + 25 + 25 22 + 22 + 25 + 25 + 25 + 35 22 + 22 + 25 + 25 + 25 + 50 22 + 22 + 25 + 25 + 25 + 60 22 + 22 + 25 + 25 + 35 + 35 22 + 22 + 25 + 25 + 35 + 50 22 + 22 + 25 + 35 + 35 + 35 22 + 22 + 35 + 35 + 35 + 35 22 + 25 + 25 + 25 + 25 + 25 2.20 / 2.51 2.20 / 2.51 2.12 / 2.43 1.92 / 2.20 1.81 / 2.07 1.70 / 1.94 2.20 / 2.52 2.08 / 2.38 1.89 / 2.16 1.78 / 2.03 1.67 / 1.91 1.95 / 2.23 1.78 / 2.03 1.68 / 1.92 2.18 / 2.50 2.04 / 2.33 1.86 / 2.12 1.75 / 2.00 1.91 / 2.19 1.75 / 2.00 1.80 / 2.06 2.14 / 2.44 2.00 / 2.28 1.82 / 2.08 1.72 / 1.97 1.88 / 2.15 1.72 / 1.97 1.70 / 2.02 1.67 / 1.91 2.10 / 2.39 2.20 / 2.51 2.20 / 2.51 2.12 / 2.43 1.92 / 2.20 1.81 / 2.07 1.70 / 1.94 2.20 / 2.52 2.08 / 2.38 1.89 / 2.16 1.78 / 2.03 1.67 / 1.91 1.95 / 2.23 1.78 / 2.03 1.68 / 1.92 2.18 / 2.50 2.04 / 2.33 1.86 / 2.12 1.75 / 2.00 1.91 / 2.19 1.75 / 2.00 1.80 / 2.06 2.14 / 2.44 2.00 / 2.28 1.82 / 2.08 1.72 / 1.97 1.88 / 2.15 1.72 / 1.97 1.70 / 2.02 1.67 / 1.91 2.38 / 2.72 2.20 / 2.51 2.20 / 2.51 2.12 / 2.43 1.92 / 2.20 1.81 / 2.07 1.70 / 1.94 2.20 / 2.52 2.08 / 2.38 1.89 / 2.16 1.78 / 2.03 1.67 / 1.91 1.95 / 2.23 1.78 / 2.03 1.68 / 1.92 2.18 / 2.50 2.04 / 2.33 1.86 / 2.12 1.75 / 2.00 1.91 / 2.19 1.75 / 2.00 1.80 / 2.06 2.43 / 2.78 2.27 / 2.60 2.07 / 2.37 1.96 / 2.23 2.13 / 2.44 1.96 / 2.23 2.00 / 2.30 2.66 / 3.04 2.38 / 2.72 2.20 / 2.51 2.20 / 2.51 2.12 / 2.43 1.92 / 2.20 1.81 / 2.07 1.70 / 1.94 2.20 / 2.52 2.08 / 2.38 1.89 / 2.16 1.78 / 2.03 1.67 / 1.91 1.95 / 2.23 1.78 / 2.03 1.68 / 1.92 2.48 / 2.83 2.32 / 2.65 2.10 / 2.41 1.99 / 2.27 2.17 / 2.47 1.99 / 2.27 2.86 / 3.27 2.43 / 2.78 2.27 / 2.60 2.07 / 2.37 1.96 / 2.23 2.13 / 2.44 1.96 / 2.23 2.82 / 3.22 2.66 / 3.04 2.38 / 2.72 2.20 / 2.51 2.20 / 2.51 2.12 / 2.43 1.92 / 2.20 1.81 / 2.07 1.70 / 1.94 2.50 / 2.86 2.36 / 2.70 2.15 / 2.45 2.02 / 2.31 1.90 / 2.17 3.10 / 3.54 2.83 / 3.24 2.68 / 3.06 2.48 / 2.83 2.32 / 2.65 2.10 / 2.41 1.99 / 2.27 3.04 / 3.48 2.78 / 3.18 2.86 / 3.27 2.43 / 2.78 2.27 / 2.60 2.07 / 2.37 1.96 / 2.23 2.99 / 3.41 2.74 / 3.13 2.82 / 3.22 2.66 / 3.04 2.38 / 2.72 2.20 / 2.51 2.50 / 2.85 3.38 / 3.85 4.38 / 5.00 4.94 / 5.65 5.49 / 6.28 2.50 / 2.86 3.31 / 3.78 4.29 / 4.91 4.86 / 5.55 5.40 / 6.17 3.10 / 3.54 4.05 / 4.62 4.59 / 5.25 2.48 / 2.83 3.24 / 3.71 4.22 / 4.82 4.77 / 5.45 3.04 / 3.48 3.98 / 4.55 2.86 / 3.27 2.43 / 2.78 3.18 / 3.64 4.14 / 4.73 4.68 / 5.36 2.99 / 3.41 3.90 / 4.47 2.82 / 3.22 2.66 / 3.04 2.38 / 2.72

Page 48

Indoor unit combination Unit A


22 + 25 + 25 + 25 + 25 + 35 22 + 25 + 25 + 25 + 25 + 50 22 + 25 + 25 + 25 + 25 + 60 22 + 25 + 25 + 25 + 35 + 35 22 + 25 + 25 + 25 + 35 + 50 22 + 25 + 25 + 35 + 35 + 35 25 + 25 + 25 + 25 + 25 + 25 25 + 25 + 25 + 25 + 25 + 35 25 + 25 + 25 + 25 + 25 + 50 25 + 25 + 25 + 25 + 25 + 60 25 + 25 + 25 + 25 + 35 + 35 25 + 25 + 25 + 25 + 35 + 50 25 + 25 + 25 + 35 + 35 + 35 1.96 / 2.24 1.79 / 2.04 1.69 / 1.93 1.84 / 2.10 1.69 / 1.93 1.73 / 1.99 2.33 / 2.66 2.19 / 2.50 2.00 / 2.28 1.89 / 2.16 2.06 / 2.35 1.89 / 2.16 1.94 / 2.22

Cooling / Heating Capacity (kW) Unit B


2.23 / 2.55 2.03 / 2.33 1.92 / 2.20 2.10 / 2.40 1.92 / 2.20 1.98 / 2.26 2.33 / 2.66 2.19 / 2.50 2.00 / 2.28 1.89 / 2.16 2.06 / 2.35 1.89 / 2.16 1.94 / 2.22

Unit C
2.23 / 2.55 2.03 / 2.33 1.92 / 2.20 2.10 / 2.40 1.92 / 2.20 1.98 / 2.26 2.33 / 2.66 2.19 / 2.50 2.00 / 2.28 1.89 / 2.16 2.06 / 2.35 1.89 / 2.16 1.94 / 2.22

Unit D
2.23 / 2.55 2.03 / 2.33 1.92 / 2.20 2.10 / 2.40 1.92 / 2.20 2.77 / 3.16 2.33 / 2.66 2.19 / 2.50 2.00 / 2.28 1.89 / 2.16 2.06 / 2.35 1.89 / 2.16 2.72 / 3.11

Unit E
2.23 / 2.55 2.03 / 2.33 1.92 / 2.20 2.93 / 3.35 2.69 / 3.08 2.77 / 3.16 2.33 / 2.66 2.19 / 2.50 2.00 / 2.28 1.89 / 2.16 2.88 / 3.29 2.65 / 3.03 2.72 / 3.11

Unit F
3.12 / 3.56 4.07 / 4.64 4.62 / 5.27 2.93 / 3.35 3.85 / 4.39 2.77 / 3.16 2.33 / 2.66 3.05 / 3.50 4.00 / 4.57 4.54 / 5.19 2.88 / 3.29 3.78 / 4.32 2.72 / 3.11

Unit G

Unit H

7 ROOMS
22 + 22 + 22 + 22 + 22 + 22 + 22 22 + 22 + 22 + 22 + 22 + 22 + 25 22 + 22 + 22 + 22 + 22 + 22 + 35 22 + 22 + 22 + 22 + 22 + 22 + 50 22 + 22 + 22 + 22 + 22 + 25 + 25 22 + 22 + 22 + 22 + 22 + 25 + 35 22 + 22 + 22 + 22 + 22 + 25 + 50 22 + 22 + 22 + 22 + 22 + 35 + 35 22 + 22 + 22 + 22 + 25 + 25 + 25 22 + 22 + 22 + 22 + 25 + 25 + 35 22 + 22 + 22 + 22 + 25 + 35 + 35 22 + 22 + 22 + 25 + 25 + 25 + 25 22 + 22 + 22 + 25 + 25 + 25 + 35 22 + 22 + 25 + 25 + 25 + 25 + 25 22 + 22 + 25 + 25 + 25 + 25 + 35 22 + 25 + 25 + 25 + 25 + 25 + 25 22 + 25 + 25 + 25 + 25 + 25 + 35 25 + 25 + 25 + 25 + 25 + 25 + 25 25 + 25 + 25 + 25 + 25 + 25 + 35 2.00 / 2.28 1.96 / 2.24 1.84 / 2.11 1.69 / 1.93 1.92 / 2.20 1.81 / 2.07 1.66 / 1.90 1.71 / 1.96 1.89 / 2.16 1.78 / 2.03 1.68 / 1.92 1.85 / 2.12 1.75 / 2.00 1.82 / 2.07 1.71 / 1.97 1.79 / 2.05 1.69 / 1.93 2.00 / 2.28 1.89 / 2.16 2.00 / 2.28 1.96 / 2.24 1.84 / 2.11 1.69 / 1.93 1.92 / 2.20 1.81 / 2.07 1.66 / 1.90 1.71 / 1.96 1.89 / 2.16 1.78 / 2.03 1.68 / 1.92 1.85 / 2.12 1.75 / 2.00 1.82 / 2.07 1.71 / 1.97 2.03 / 2.32 1.92 / 2.20 2.00 / 2.28 1.89 / 2.16 2.00 / 2.28 1.96 / 2.24 1.84 / 2.11 1.69 / 1.93 1.92 / 2.20 1.81 / 2.07 1.66 / 1.90 1.71 / 1.96 1.89 / 2.16 1.78 / 2.03 1.68 / 1.92 1.85 / 2.12 1.75 / 2.00 2.07 / 2.37 1.96 / 2.23 2.03 / 2.32 1.92 / 2.20 2.00 / 2.28 1.89 / 2.16 2.00 / 2.28 1.96 / 2.24 1.84 / 2.11 1.69 / 1.93 1.92 / 2.20 1.81 / 2.07 1.66 / 1.90 1.71 / 1.96 1.89 / 2.16 1.78 / 2.03 1.68 / 1.92 2.11 / 2.41 1.99 / 2.27 2.07 / 2.37 1.96 / 2.23 2.03 / 2.32 1.92 / 2.20 2.00 / 2.28 1.89 / 2.16 2.00 / 2.28 1.96 / 2.24 1.84 / 2.11 1.69 / 1.93 1.92 / 2.20 1.81 / 2.07 1.66 / 1.90 1.71 / 1.96 2.14 / 2.45 2.02 / 2.31 1.91 / 2.19 2.11 / 2.41 1.99 / 2.27 2.07 / 2.37 1.96 / 2.23 2.03 / 2.32 1.92 / 2.20 2.00 / 2.28 1.89 / 2.16 2.00 / 2.28 1.96 / 2.24 1.84 / 2.11 1.69 / 1.93 2.19 / 2.50 2.06 / 2.35 1.89 / 2.16 2.72 / 3.10 2.14 / 2.45 2.02 / 2.31 2.68 / 3.06 2.11 / 2.41 1.99 / 2.27 2.07 / 2.37 1.96 / 2.23 2.03 / 2.32 1.92 / 2.20 2.00 / 2.28 1.89 / 2.16 2.00 / 2.28 2.23 / 2.55 2.93 / 3.34 3.85 / 4.40 2.19 / 2.50 2.88 / 3.29 3.78 / 4.32 2.72 / 3.10 2.14 / 2.45 2.83 / 3.24 2.68 / 3.06 2.11 / 2.41 2.78 / 3.18 2.07 / 2.37 2.74 / 3.13 2.03 / 2.32 2.69 / 3.07 2.00 / 2.28 2.65 / 3.03

8 ROOMS
22 + 22 + 22 + 22 + 22 + 22 + 22 + 22 22 + 22 + 22 + 22 + 22 + 22 + 22 + 25 22 + 22 + 22 + 22 + 22 + 22 + 25 + 25 22 + 22 + 22 + 22 + 22 + 25 + 25 + 25 1.75 / 2.00 1.72 / 1.96 1.69 / 1.93 1.66 / 1.90 1.75 / 2.00 1.72 / 1.96 1.69 / 1.93 1.66 / 1.90 1.75 / 2.00 1.72 / 1.96 1.69 / 1.93 1.66 / 1.90 1.75 / 2.00 1.72 / 1.96 1.69 / 1.93 1.66 / 1.90 1.75 / 2.00 1.72 / 1.96 1.69 / 1.93 1.66 / 1.90 1.75 / 2.00 1.72 / 1.96 1.69 / 1.93 1.89 / 2.16 1.75 / 2.00 1.72 / 1.96 1.92 / 2.20 1.89 / 2.16 1.75 / 2.00 1.96 / 2.23 1.92 / 2.20 1.89 / 2.16

Page 49

Outdoor Units
MUZ-GC35VA / MUZ-FD25/35VAH / SUZ-KA25/35VA
Upper View

>

Side View Front View

>

>

MUZ-HC25/35VA(B) / MUZ-GC25VA

Upper View

>

Side View Front View

>

>

Dimensions
Page 50

Dimensions

MUH-GA50VB
Upper View

>

Side View Front View

>

>

MUH-GA60VB / MUZ-GB50VA / MUZ-GA60/71VA / SUZ-KA50VA

Upper View

>

Front View

>

Side View

>
Outdoor Unit Dimensions
Page 51

M Series Range 2008

M Series Range 2008

Accessories / Optional Extras


M Series
Air Cleaning Filter Catechin Filter Anti-Allergy Enzyme Filter
MAC-1700FT - for MSH-GA50/60VB (10 pack)

MAC-3003CF

- for MSZ-HC25/35VA(B) (10 pack)

MAC-408FT -E MAC-415FT -E MAC-2300FT

- for MSZ-GC22-35VA (10 pack) - for MSZ-GB50VA (10 pack) - for MSZ-GA60-71VA (10 pack)

Wired Remote controller

PAR-21MAA MAC-821SC-E

- for MSZ-GC22-35VA, MSZ-GB50VA, MSZ-GA60/71VA, MSZ-FD25/35VA & MFZ-KA25-50VA - Centralised Simple ON/OFF Remote Controller for MXZ Multi-Splits

Interfaces

MAC-399IF MAC-397IF

- for connection to M-NET system - for Contact Terminal, PAR-21MAA Wired Remote Controller and MAC-821SC-E Centralised ON/OFF Remote Controller

Air Outlet Guide

PAC-SG59SG-E - for MXZ-8A140VA

Accessories / Optional Extras

Page 52

Mr Slim
Packaged Split-System Air Conditioning

The Mr Slim range


Compact and versatile, the
Suitable to heat or cool a huge variety of applications, the Mr Slim range is one of Britains best selling air conditioning split-systems. Combine the efficiency with the complete versatility that this range has to offer and the possibilities are virtually infinite.
The 2008 Mr Slim range has been updated with new features, as well as the already impressive efficiency levels being improved. New to the range are the 19 & 22kW outdoor models, available in both Power Inverter and Standard Inverter options. The smaller outdoor models have also undergone improvements, in line with Mitsubishi Electrics forward looking approach. New indoor units include the SEZ-KD ducted models and four new large capacity ducted models (PEA-RP-GA) available in up to 44kW cooling capacity. A new range of 4-way blow cassettes (PLA-RP-BA2) are now available with improved COP's and EER's, further increasing Mitsubsihi Electrics energy efficient portfolio. Finally a range of Heat Pump Air Curtains have been developed with Thermoscreens, for use with our Power Inverter models, an ideal application for a retail establishment. Mr Slim units are more than just physically compact and discreet. Theyre also amongst the quietest operating units available, which means that apart from enjoying a comfortable, controllable environment, users hardly know Mr Slim is there at all.

Page 54

options are endless

Easy to fit

An installers favourite, the excellent design of the Mr Slim range ensures quick and simple installation with the minimum of disruption. With extensive pipe runs of up to120m, this versatile range makes it easier to select a layout to install the unit.

wherever you need

Power Inverter
is now stronger than ever. The technological developments applied to this new range of equipment offer the end user some of the highest energy efficiency ratings available, alongside greater application flexibility. This range is available in single and 3-phase options, the latter having running currents that are more than half that of the single phase option, offering a clear benefit to business premises that already have 3-phase supply installed. All models have low starting currents of 5 amps.

The Mr Slim Power Inverter range

The issue of using existing R22/R407c pipe work has been resolved
using Mitsubishi Electrics unique Replace Technology, offering the opportunity to upgrade older, less efficient systems with the minimum of cost and installation disruption.

Improved COP / EER Ratings - COP and EER ratings have increased across
the board with many models within our range now having energy labels of A in both heating and cooling.

Reducing Power Consumption by 70% - The Mr Slim Power Inverter can


reduce power consumption by up to 70% compared to a previously installed non-inverter model* 1, making the energy cost savings associated with this range truly remarkable. A high power function also delivers increased capacity at times of high demand, allowing the room target temperature to be reached as rapidly as possible from start up.

New 19 & 22kW models now available The unit size of these models has now been significantly reduced as displayed here.

*1 Based on the following operating conditions - Place-Office in Tokyo, Japan / Operating time-8am to 8pm, 6 days/week / Operating period-Cooling: April 16 - November 8
Heating: December 14 - March 23 / Set temperature-Cooling: 27C, Heating: 20C. Non-inverter model installed eight years ago is a PLH-3GKHB / PUH-3YKA. Power Inverter model is a PLA-RP71BA2 / PUHZ-RP71VHA3.

Page 56

Silent Operation
Operation has been made near-silent (67% quieter than corresponding R22 outdoor unit*1) as a result of improvement in the design of the fan blades and the new grille shape. The Power Inverter is even quieter at night when outside temperatures drop, as it can be set to low-noise mode (cooling only) reducing operating noise by 3dBA (50% quieter than normal day mode). A low-noise priority function is also available by connecting a separate commercially available timer or selector switch. When a signal is received from the timer or switch, the unit automatically runs in low-noise mode.

Duty Standby Operation


3 new functions are available with Mr Slim systems* :
2

Rotation
2 outdoor units (master & sub) operate alternately, switching every 1, 3, 5, 7, 14, 28 days (selectable).

Rotate

Back Up
When master outdoor unit fails, sub unit begins operation.

Back Up

Join In
When master outdoor unit fails to reach set temperature, sub unit operates in conjunction (available in cooling mode only).
* 1 When comparing the Power Inverter (PUHZ-RP71VHA3) with R22 (PUH3-VKA) in cooling. * 2 Not available when using SUZ outdoor units. Must be used in conjunction with a PAR-21MAA controller.

Join In

Page 57

Standard Inverter
The Standard Inverter models provide an inverter solution at a lower
capital cost than the Power Inverter range. These outdoor models continue to offer high efficiency as standard, with some systems qualifying for Enhanced Capital Allowance. Models are available in 10, 12.5 & 14kW single phase and now 19 & 22kW three phase.

Improved COP / EER Figures - COP / EER figures have been improved
when compared to the previous R407c range.
COP
Example:

EER EER COP

COP Improved by 27%


B

2.61
D

2.69
E

3.01 3.41
B

R407c Fixed speed unit PUH-P100VGAA

Standard Inverter PUHZ-P100VHA2

10.0kW model now has a compact single fan design and weighs less, when compared
to its Power Inverter equivalent, making installation easier.

Compared to Power Inverter


Height reduced by 407mm Power Inverter
121kg

Weight reduced by 46kg Standard Inverter


407mm

75kg

1350mm

330mm

950mm

943mm
330mm

950mm

Silent Outdoor Unit - Low Noise Mode


Low noise mode can be set at night time to reduce noise levels by approximately 50%. The example here is using a PUHZ-P100VHA2.
1/2 the audible sound (compared to daytime)

Day 50dBA
Outdoor Temperature 35C

3dBA Less

Night 47dBA
Outdoor Temperature 25C

Page 58

Inverter solutions
at a lower price
SUZ outdoor units are able to be connected to selected Mr Slim indoor units, creating a new
range of low cost inverter driven systems.

Design with Environmental Consideration


Pump down switch
Pushing a switch starts / stops refrigerant recovery operation automatically. This work will then be completed by closing a valve.

Pump down switch

Smooth refrigerant recovery can be assured by pushing the pump down switch at unit movement / renewal.

Page 59

New 4-Way Blow Cassette


The PLA-RP-BA(2) (PLFY-P-VBM-E for City Multi) 4-Way Blow Cassette, offers a range of new features, as well as a new design and pure white colour.
s Previous product s New product

Wide Airflow
The new wide shape vane (capable of wide angle air supply) provides comfort at the corners of a room, regardless of cooling or heating operation. A reduction in the air speed by 20% (compared to the previous product) eliminates the uncomfortable draft sensation often experienced.

Reduced Draft Air Distribution


Reduced draft air distribution allows the vanes to supply airflow horizontally, thus preventing discomfort due to excessive cooling or from direct exposure of occupants to the air blow.

Reduced Draft Air Distribution

Independent Vane Control


If the airflow direction needs to be changed as a result of an altered room layout or due to the mode selected (i.e. cooling or heating), the air direction of each vane can be set independently using the PAR-21MAA wired remote controller.
Horizontal blow PAR-21MAA Adjustable Down blow

Fixed

Automatic Airflow Adjustment Mode


The automatic airflow adjustment mode is provided in addition to the 4 normal airflow stages and allows automatic adjustment of the airflow in accordance with the difference between the set temperature and the room temperature. For example: The automatic airflow adjustment mode allows quick cooling of a room using high mode, then when the room temperature has stabilised, the low mode will be applied to maximise comfort.
Low Medium 2 Medium 1 High
Automatic airflow adjustment

Grille with Automatic Filter Lowering Function (Optional) Automatic


This grille can be operated by both the wired remote controller and the exclusive infra-red remote controller. It can be lowered in 8 steps down to 4m in accordance with the ceiling height, enabling you to easily clean the air filter. Regular cleaning of the filter is an important factor in saving energy.
lowering to

4m

Elevation Grille Remote Controller (comes with the grille)

PAR-21MAA Wired Remote Controller

Page 60

The (optional corner panel) Provides Even Temperature Distribution and Reduces Energy Consumption
The I-See Sensor uses new temperature sensing technology developed by Mitsubishi Electric. In order to create a comfortable environment in shops and offices, it is essential to control the temperature near the floor where occupants and visitors gather. The I-See Sensor measures the infra-red rays generated from the surrounding wall and floor surfaces and converts these into temperature values. In addition, floor temperatures are also measured at distant spots, allowing optimum airflow to reach these areas. s I-See Sensoroperation: The I-See Sensorrotates slowly in intervals of 5 seconds, correctly measuring the temperature of the entire floor space.

360
The "I-See Sensor" rotates to measure the floor temperature

5 seconds

5 seconds

5 seconds

5 seconds

Sensible Temperature Control to Prevent Excessive Cooling and Heating


By measuring the inlet temperature and floor temperature, a temperature felt by the human body (sensible temperature) will be calculated and maintained, suppressing excessive cooling and heating.

In the past... only the inlet temperature near


the ceiling was measured, tending to overlook the uneven temperature distribution near the floor. Conventional air conditioning in shops and offices only measured the temperature near to the ceiling, therefore the uneven temperature distribution between the ceiling and the floor remained unchecked. As a result, the set temperature tended to be higher in order to obtain comfort at floor level.
Inlet temperature sensor

both the floor temperature and inlet temperature are measured. The New 4-Way Blow Ceiling Cassette with the I-See Sensor simultaneously measures the floor and inlet temperatures, providing improved comfort to occupants and increased energy savings.
Inlet temperature sensor

With I-See Sensor...

Area measured by cassette model without "I-See Sensor"

360 sensing
With the I-See Sensor plus automatic airflow adjustment mode. Set temperature is 20C (in Heating)
37C 25C 13C

Area measured by the cassette model equipped with "I-See Sensor"

2.7m

Without I-See Sensor. Set temperature is 23C (in Heating)


e.g. To achieve a sensible temperature of 20C, the set temperature must be as high as 23C

e.g. With the set temperature at 20C, a sensible temperature of 20C at floor level can be obtained.

37C 25C 13C

Page 61

The adaptable Mr Slim range

Designed to fit anywhere


Available in a variety of options, the Mr Slim range fits in wherever its needed. Indoor units can be four way blow cassettes, ducted, wall or ceiling mounted. Up to four indoor units can then be connected to a single outdoor unit providing the ideal air conditioning solution.

Simple technology
at its best
Systems marked with the ECA logo have an energy label of A or B, are registered on the Energy Technology List and hence qualify for 100% first year enhanced capital allowances (whole system cost and reasonable cost of installation). For further information please go to www.eca.gov.uk

Nominal conditions cooling: indoor 27C DB, 19C WB; outdoor 35C DB, 24C WB. Nominal conditions heating: indoor 20C DB; outdoor 7C DB, 6C WB. UK Conditions: Summer; indoor 21C DB, 15C WB; outdoor 27C DB. Winter; indoor 21C DB; outdoor -1C WB.

Page 62

Contents
64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112 115 116

PKA-RP Power Inverter Heat Pump, Wall Mounted System PKA-RP Standard Inverter Heat Pump, Wall Mounted System PKA-RP Heat Pump, Wall Mounted System SEZ-KD-VA Inverter Heat Pump, Ceiling Concealed Ducted System PEAD-RP Power Inverter Heat Pump, Ceiling Concealed Ducted System PEAD-RP Standard Inverter Heat Pump, Ceiling Concealed Ducted System PEAD-RP Heat Pump, Ceiling Concealed Ducted System PEA-RP-GA Power Inverter Heat Pump, Large Capacity Ceiling Concealed Ducted System PEA-RP-GA Standard Inverter Heat Pump, Large Capacity Ceiling Concealed Ducted System SLZ-KA-VA Inverter Heat Pump, 600x600 4-Way Blow Ceiling Cassette System PLA-RP Power Inverter Heat Pump, 4-Way Blow Ceiling Cassette System PLA-RP Standard Inverter Heat Pump, 4-Way Blow Ceiling Cassette System PLA-RP Heat Pump, 4-Way Blow Ceiling Cassette System PCA-RP Power Inverter Heat Pump, Ceiling Suspended System PCA-RP Standard Inverter Heat Pump, Ceiling Suspended System PCA-RP Heat Pump, Ceiling Suspended System PCA-RP-HA Power Inverter Heat Pump, Stainless Steel Ceiling Suspended System PCA-RP-HA Standard Inverter Heat Pump, Stainless Steel Ceiling Suspended System PCA-RP-HA Heat Pump, Stainless Steel Ceiling Suspended System PSA-RP Power Inverter Heat Pump, Floor Standing System PSA-RP Standard Inverter Heat Pump, Floor Standing System PSA-RP Heat Pump, Floor Standing System PHV DXE Heat Pump, Air Curtain Mr Slim Multi-Split Systems Heat Pump Outdoor Units Air Handling Unit Controller Mr Slim Accessories / Optional Extras

Page 63

PKA-RP Power Inverter Heat Pump


Wall Mounted System
s s

Adjustable louvres for uniform air distribution Internal pipe connection to wall mounted unit for easy and neat installation

Technical Information
PKA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) COP / EER (nominal) ENERGY LABEL AIRFLOW (m3/min) PIPE SIZE mm(in) NOISE (dBA) DIMENSIONS (mm) Heating/Cooling Lo-Mi1-Mi2-Hi Gas Liquid Lo-Mi1-Mi2-Hi Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) HRC (A) INTERCONNECTING CABLE No. CORES PKA-RP35GAL 3.6 (1.6-5.2) 3.6 (1.6-4.5) 3.05 (1.35-4.4) 3.25 (1.45-4.05) 0.87 3.41 / 3.50 B /A 9-10-11-12 12.7 (1/2) 6.35 (1/4) 36-38-41-43 990 235 340 16 Fed by Outdoor Unit Single 6 4 PKA-RP50FAL2 6.0 (2.5-7.3) 5.0 (2.3-5.6) 5.1 (2.15-6.2) 4.5 (2.05-5.05) 0.86 3.41 / 3.01 B/B 15-20 12.7 (1/2) 6.35 (1/4) 39-45 1400 235 340 24 Fed by Outdoor Unit Single 6 4 PKA-RP60FAL 7.0 (2.8-8.2) 6.0 (2.7-6.7) 5.95 (2.4-6.95) 5.4 (2.45-6.05) 0.83 3.48 / 3.87 B /A 15-20 15.88 (5/8) 9.52 (3/8) 39-45 1400 235 340 24 Fed by Outdoor Unit Single 6 4 PKA-RP71FAL 7.6 (3.5-10.2) 7.1 (3.3-8.1) 6.45 (3.0-8.65) 6.4 (2.95-7.3) 0.77 3.41 / 3.59 B /A 15-20 15.88 (5/8) 9.52 (3/8) 39-45 1400 235 340 24 Fed by Outdoor Unit Single 6 4 PKA-RP100FAL 11.2 (4.5-14.0) 10.0 (4.9-11.4) 9.5 (3.85-11.9) 9.0 (4.4-10.25) 0.77 3.45 / 3.41 B /A 22-28 15.88 (5/8) 9.52 (3/8) 41-46 1680 235 340 28 Fed by Outdoor Unit Single 6 4

PUHZ-RP - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Single Phase Heating/Cooling [MAX] 3 Phase FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 30m Heating/Cooling PUHZ-RP35VHA3 46 / 44 42 800 300 + 23 600 220-240v, 50Hz Single 1.06 / 1.03 0.94 / 0.86 5 4.56 / 4.34 [13] 16 3 50 30 2.5 PUHZ-RP50VHA3 46 / 44 42 800 300 + 23 600 220-240v, 50Hz Single 1.76 / 1.66 1.57 / 1.41 5 6.9 / 6.59 [13] 16 3 50 30 2.5 PUHZ-RP60VHA3 48 / 47 68 950 330 + 30 943 220-240v, 50Hz Single 2.01 / 1.55 1.79 / 1.32 5 7.93 / 7.04 [19] 25 3 50 30 3.5 PUHZ-RP71VHA3 48 / 47 68 950 330 + 30 943 220-240v, 50Hz Single 2.23 / 1.98 2.00 / 1.68 5 10.17 / 8.47 [19] 25 3 50 30 3.5 PUHZ-RP100VHA3/YHA3 51 / 49 116 / 130 950 330 + 30 1350 220-240v, 50Hz / 380-415,50Hz Single / 3 3.25 / 2.93 2.89 / 2.49 5 12.91 / 13.05 [28] 4.55 / 4.60 [13] 32 / 16 3/5 75 30 5.0

Page 64

Dimensions

INDOOR UNIT PKA-RP35GAL


Lower Side View

>

Left Side View

>

Front View

>

Right Side View

>

INDOOR UNIT PKA-RP50-71FAL(2)


Lower Side View

>

Left Side View

>

Front View

>

< Right Side View

INDOOR UNIT PKA-RP100FAL


Lower Side View

>

Left Side View

>

Front View

>

< Right Side View

Page 65

PKA-RP Power Inverter Heat Pump

Mr Slim Range 2008

PKA-RP Standard Inverter Heat Pump


Wall Mounted System
The Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the more expensive Power Inverter range.
s s

Adjustable louvres for uniform air distribution Internal pipe connection to wall mounted unit for easy and neat installation

Technical Information
PKA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) COP / EER (nominal) ENERGY LABEL AIRFLOW (m3/min) PIPE SIZE mm(in) NOISE (dBA) DIMENSIONS (mm) Heating/Cooling Lo-Hi Gas Liquid Lo-Mi1-Mi2-Hi Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) - HRC (A) INTERCONNECTING CABLE No. CORES PKA-RP100FAL 11.2 (4.5-12.5) 9.4 (4.9-11.2) 9.5 (3.85-10.65) 8.45 (4.4-10.1) 0.79 3.21 / 3.01 C/B 22-28 15.88 (5/8) 9.52 (3/8) 41-46 1680 235 340 28 Fed by Outdoor Unit Single 6 4

PUHZ-P - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kW) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 20m Heating/Cooling (nominal) Heating/Cooling (UK) Heating/Cooling PUHZ-P100VHA2 54 / 50 75 950 330 + 30 943 220-240v, 50Hz Single 3.49 / 3.12 3.11 / 2.65 4 13.14 / 12.78 [28] 32 3 50 30 2.7

Page 66

Dimensions

INDOOR UNIT PKA-RP100FAL

Lower Side View

>

Left Side View

>

Front View

>

< Right Side View

Page 67

PKA-RP Standard Inverter Heat Pump

Mr Slim Range 2008

PKA-RP Heat Pump


Wall Mounted System
The Heat Pump system provides a low cost alternative to three phase Power Inverter systems.
s s

Adjustable louvres for uniform air distribution Internal pipe connection to wall mounted unit for easy and neat installation

Technical Information
PKA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) AIRFLOW (m3/min) PIPE SIZE mm(in) NOISE (dBA) DIMENSIONS (mm) Lo-Mi1-Mi2-Hi Gas Liquid Lo-Mi1-Mi2-Hi Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) - HRC (A) INTERCONNECTING CABLE No. CORES PKA-RP100FAL 11.5 9.8 9.8 8.8 0.77 22-28 15.88 (5/8) 9.52 (3/8) 41-46 1680 235 340 28 Fed by Outdoor Unit Single 6 4

PUH-P - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kW) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 30m Heating/Cooling (nominal) Heating/Cooling (UK) Heating/Cooling PUH-P100YHA 52 / 50 94 950 330 + 30 943 380-415v, 50Hz 3 3.47 / 3.50 3.09 / 2.98 45 5.7 / 5.91 [11.8] 20 5 50 50 4.4

Page 68

Dimensions

INDOOR UNIT PKA-RP100FAL

Lower Side View

>

Left Side View

>

Front View

>

< Right Side View

Page 69

PKA-RP Heat Pump

Mr Slim Range 2008

SEZ-KD-VA Inverter Heat Pump


Ceiling Concealed Ducted System
Designed for homes, offices, restaurants or shops, the SEZ-KD-VA series operates at low noise levels. Its new improved low unit height and lightweight design also help to make installation easier and more convenient.

Note: Optional interfaces for M-NET connectivity (MAC-399IF) and group control, fault/run (MAC-397IF) are available. Please see accessories / optional extras section.

Technical Information
SEZ-KD-VA - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) COP / EER (nominal) ENERGY LABEL AIRFLOW (m3/min) Heating/Cooling Lo-Mi-Hi Lo-Mi1-Mi2-Hi SEZ-KD25VA 3.0 (0.9-4.5) 2.5 (0.9-3.2) 2.5 (0.75-3.75) 2.5 (0.9-3.15) 0.80 3.61 / 3.21 A /A 5.5-7.0-9.0 5-15-35-50 9.52 (3/8) 6.35 (1/4) 23-26-30 790 700 200 18 Fed by Outdoor Unit Single 6 4 SEZ-KD35VA 4.0 (0.9-5.0) 3.5 (1.0-3.9) 3.3 (0.75-4.15) 3.45 (1.0-3.85) 0.78 3.61 / 3.21 A /A 7-9-11 5-15-35-50 9.52 (3/8) 6.35 (1/4) 23-28-33 990 700 200 21 Fed by Outdoor Unit Single 6 4 SEZ-KD50VA 6.0 (1.1-7.2) 5.0 (1.1-5.6) 5.0 (0.9-6.0) 4.95 (1.1-5.55) 0.76 3.21 / 2.81 C/C 10-12.5-15 5-15-35-50 12.7 (1/2) 6.35 (1/4) 30-34-37 990 700 200 23 Fed by Outdoor Unit Single 6 4 SEZ-KD60VA 7.0 (0.9-8.0) 5.5 (1.1-6.3) 5.8 (0.75-6.65) 5.45 (1.1-6.25) 0.79 3.41 / 2.91 B/C 12-15-18 5-15-35-50 15.88 (5/8) 6.35 (1/4) 30-34-38 1190 700 200 27 Fed by Outdoor Unit Single 6 4 SEZ-KD71VA 8.1 (0.9-10.4) 7.1 (0.9-8.3) 6.75 (0.75-8.65) 7.05 (0.9-8.25) 0.74 3.42 / 2.81 B/C 12-16-20 5-15-35-50 15.88 (5/8) 9.52 (3/8) 30-35-40 1190 700 200 27 Fed by Outdoor Unit Single 6 4

EXTERNAL STATIC PRESSURE Pa PIPE SIZE mm(in) Gas Liquid NOISE (dBA) DIMENSIONS (mm)

Lo-Mi-Hi Width Depth Height

WEIGHT (kg) ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) - HRC (A) INTERCONNECTING CABLE No. CORES

SUZ-KA-VA - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) (Lo-Hi) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. CORES MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 7m Heating/Cooling SUZ-KA25VA 46 / 46 33 800 285 550 220-240v, 50Hz 0.83 / 0.778 0.76 / 0.62 3.65 4.04 / 3.44 [8.16] 16 3 20 12 0.9 SUZ-KA35VA 48 / 47 37 800 285 550 220-240v, 50Hz 1.108 / 1.09 1.01 / 0.87 4.75 5.21 / 5.01 [9.18] 16 3 20 12 1.05 SUZ-KA50VA 53-55 / 51-53 53 840 330 850 220-240v, 50Hz 1.87 / 1.78 1.70 / 1.42 6.75 6.98 / 7.38 [16] 25 3 30 30 1.6 SUZ-KA60VA 53-55 / 51-53 53 840 330 850 220-240v, 50Hz 2.05 / 1.89 1.87 / 1.51 9.75 10.38 / 8.98 [16] 25 3 30 30 1.8 SUZ-KA71VA 53-55 / 51-53 58 840 330 850 220-240v, 50Hz 2.37 / 2.53 2.15 / 2.02 10.3 10.74 / 11.14 [16] 25 3 30 30 2.0

Page 70

Dimensions

INDOOR UNIT SEZ-KD25-71VA

Upper View

>

Front View

>

Side View

>
SEZ-KD-VA Inverter Heat Pump
Page 71

Models Size 25 Size 35-50 Size 60-71

A 700 900 1100

B 752 952 1152

C 798 998 1198

D 660 860 1060

E 7 9 11

F 600 800 1000

Mr Slim Range 2008

PEAD-RP Power Inverter Heat Pump


Ceiling Concealed Ducted System

Technical Information
PEAD-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) COP / EER (nominal) ENERGY LABEL AIRFLOW (m3/min) PIPE SIZE mm(in) Heating/Cooling Lo-Hi Gas Liquid EXTERNAL STATIC PRESSURE (Pa) Lo-Hi NOISE (dBA) DIMENSIONS (mm) Lo-Hi (*4) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) - HRC (A) INTERCONNECTING CABLE No. CORES PEAD-RP35EA2 4.1 (1.6-5.2) 3.6 (1.6-4.5) 3.5 (1.35-4.4) 3.25 (1.45-4.05) 0.89 3.41 / 3.21 B /A 13.5-17 12.7 (1/2) 6.35 (1/4) 30-70 36-40 (38-44) 935 700 295 33 Single 6 4 PEAD-RP50EA 6.0 (2.5-7.3) 4.9 (2.3-5.6) 5.1 (2.15-6.2) 4.4 (2.05-5.05) 0.82 3.64 / 3.22 A /A 13.5-17 12.7 (1/2) 6.35 (1/4) 30-70 36-40 (38-44) 935 700 295 35 Single 6 4 PEAD-RP60EA 7.0 (2.8-8.2) 6.0 (2.7-6.7) 5.95 (2.4-6.95) 5.4 (2.45-6.05) 0.79 3.68 / 3.23 A /A 17-21 15.88 (5/8) 9.52 (3/8) 30-70 37-41 (39-46) 1175 700 295 42 Single 6 4 PEAD-RP71EA 8.0 (3.5-10.2) 7.1 (3.3-8.1) 6.8 (3.0-8.65) 6.4 (2.95-7.3) 0.83 3.42 / 3.30 B /A 20-25 15.88 (5/8) 9.52 (3/8) 70-130*1 37-41 (40-45) 1175 740 325 44 Single 6 4 PEAD-RP100EA2 PEAD-RP125EA PEAD-RP140EA 11.2 (4.5-14.0) 10.0 (4.9-11.4) 9.5 (3.85-11.9) 9.0 (4.4-10.25) 0.86 3.51 / 3.27 B /A 33.5-42 15.88 (5/8) 9.52 (3/8) 70-130*2 44-50 (46-52) 1415 740 325 65 Single 6 4 14.0 (5.0-16.0) 12.5 (5.5-14.0) 11.9 (4.25-13.6) 11.25 (4.95-12.6) 0.82 3.61 / 3.21 A /A 33.5-42 15.88 (5/8) 9.52 (3/8) 70-130*3 44-50 (46-52) 1415 740 325 65 Single 6 4 16.0 (5.0-18.0) 14.0 (5.5-15.3) 13.6 (4.25-15.3) 12.6 (4.95-13.75) 0.83 3.41 / 3.01 B/B 36.5-46 15.88 (5/8) 9.52 (3/8) 70-130*3 46-51 (47-53) 1715 740 325 70 Single 6 4

Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit

Notes: External static pressure - (35-60: 30 + 70Pa connections as standard) / (71-140: 130Pa optional fan motor - *1 PAC-SK005MT-F, *2 PAC-SK004MT-F, *3 PAC-SK003MT-F). *4 70Pa (35-60) / 130Pa optional fan motor (71-140).

PUHZ-RP - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Single Phase Heating/Cooling [MAX] 3 Phase FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 30m Heating/Cooling PUHZ-RP35VHA3 PUHZ-RP50VHA3 PUHZ-RP60VHA3 PUHZ-RP71VHA3 PUHZ-RP100VHA3/YHA3 PUHZ-RP125VHA2/YHA2 PUHZ-RP140VHA2/YHA2 46 / 44 42 800 300 + 23 600 220-240v, 50Hz Single 1.20 / 1.12 1.05 / 0.95 5 4.84 / 4.62 [13] 16 3 50 30 2.5 46 / 44 42 800 300 + 23 600 220-240v, 50Hz Single 1.65 / 1.52 1.47 / 1.29 5 7.08 / 6.77 [13] 16 3 50 30 2.5 48 / 47 68 950 330 + 30 943 220-240v, 50Hz Single 1.90 / 1.86 1.69 / 1.58 5 8.2 / 7.31 [19] 25 3 50 30 3.5 48 / 47 68 950 330 + 30 943 220-240v, 50Hz Single 2.34 / 2.15 2.08 / 1.83 5 11.29 / 9.59 [19] 25 3 50 30 3.5 51 / 49 116 / 130 950 330 + 30 1350 Single / 3 3.19 / 3.06 2.84 / 2.60 5 15.01 / 15.15 [28] 6.65 / 6.70 [13] 32 / 16 3/5 75 30 5.0 52 / 50 116 / 130 950 330 + 30 1350 Single / 3 3.88 / 3.89 3.45 / 3.31 5 18.6 / 18.15 [28] 7.82 / 7.66 [13] 32 / 16 3/5 75 30 5.0 52 / 50 116 / 130 950 330 + 30 1350 Single / 3 4.69 / 4.65 4.17 / 3.95 5 22.61 / 22.34 [29.5] 9.15 / 9.06 [13] 40 / 16 3/5 75 30 5.0

220-240v, 50Hz / 380-415,50Hz 220-240v, 50Hz / 380-415,50Hz 220-240v, 50Hz / 380-415,50Hz

Page 72

Dimensions

INDOOR UNIT PEAD-RP35-60EA(2)


Upper View

>

Front View

>

Side View

>

Models Size 35-50 Size 60

A 772 1012

B 305 280

C 290

D 830 1070

E 804 1044

INDOOR UNIT PEAD-RP71-140EA(2)


Upper View

>

Side View Front View

>

>

Models Size 71 Size 100-125 Size 140

A 1012 1252 1552

B 280 360 460

C 290 370 470

D 1070 1310 1610

E 1044 1284 1584


Page 73

PEAD-RP Power Inverter Heat Pump

Mr Slim Range 2008

PEAD-RP Standard Inverter Heat Pump


Ceiling Concealed Ducted System
The Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the more expensive Power Inverter range.

Technical Information
PEAD-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) COP / EER (nominal) ENERGY LABEL AIRFLOW (m3/min) PIPE SIZE mm(in) Heating/Cooling Lo-Hi Gas Liquid EXTERNAL STATIC PRESSURE (Pa) Lo-Hi NOISE (dBA) DIMENSIONS (mm) Lo-Hi (*4) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) - HRC (A) INTERCONNECTING CABLE No. CORES PEAD-RP35EA2 4.1 (0.9-5.0) 3.6 (1.0-3.9) 3.4 (0.75-4.15) 3.55 (1.0-3.85) 0.90 3.63 / 3.21 A /A 13.5-17 9.52 (3/8) 6.35 (1/4) 30-70 36-40 (38-44) 935 700 295 33 Single 6 4 PEAD-RP50EA 5.9 (0.9-7.2) 4.9 (1.1-5.6) 4.9 (0.75-6.0) 4.85 (1.1-5.55) 0.79 3.49 / 2.82 B/C 13.5-17 12.7 (1/2) 6.35 (1/4) 30-70 36-40 (38-44) 935 700 295 35 Single 6 4 PEAD-RP60EA 7.0 (0.9-8.0) 6.0 (1.1-6.3) 5.8 (0.75-6.65) 5.95 (1.1-6.25) 0.80 3.38 / 2.93 C/C 17-21 15.88 (5/8) 6.35 (1/4) 30-70 37-41 (39-46) 1175 700 295 42 Single 6 4 PEAD-RP71EA 8.0 (0.9-10.2) 7.1 (0.9-8.1) 6.65 (0.75-8.5) 7.05 (0.9-8.05) 0.81 3.21 / 2.81 C/C 20-25 15.88 (5/8) 9.52 (3/8) 70-130*1 37-41 (40-45) 1175 740 325 44 Single 6 4 PEAD-RP100EA2 PEAD-RP125EA PEAD-RP140EA 11.2 (4.5-12.5) 9.4 (4.9-11.2) 9.5 (3.85-10.65) 8.45 (4.4-10.1) 0.86 3.41 / 3.01 B/B 33.5-42 15.88 (5/8) 9.52 (3/8) 70-130*2 44-50 (46-52) 1415 740 325 65 Single 6 4 14.0 (5.0-16.0) 12.3 (5.5-14.0) 11.9 (4.25-13.6) 11.05 (4.95-12.6) 0.83 3.41 / 2.81 B/C 33.5-42 15.88 (5/8) 9.52 (3/8) 70-130*3 44-50 (46-52) 1415 740 325 65 Single 6 4 16.0 (5.0-18.0) 13.6 (5.5-15.0) 13.6 (4.25-15.3) 12.25 (4.95-13.5) 0.84 3.21 / 2.61 C/D 36.5-46 15.88 (5/8) 9.52 (3/8) 70-130*3 46-51 (47-53) 1715 740 325 70 Single 6 4

Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit

Notes: External static pressure - (35-60: 30 + 70Pa connections as standard) / (71-140: 130Pa optional fan motor - *1 PAC-SK005MT-F, *2 PAC-SK004MT-F, *3 PAC-SK003MT-F). *4 70Pa (35-60) / 130Pa optional fan motor (71-140).

SUZ-KA / PUHZ-P - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) (Lo-Hi) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) Heating/Cooling SUZ-KA35VA 48 / 47 37 800 285 550 220-240v, 50Hz Single 1.13 / 1.12 1.03 / 0.90 4.75 5.36 / 5.16 [9.18] 16 3 20 12 1.05 SUZ-KA50VA 53-55 / 51-53 53 840 330 850 220-240v, 50Hz Single 1.69 / 1.74 1.54 / 1.39 6.75 6.96 / 7.36 [16] 25 3 30 30 1.6 SUZ-KA60VA 53-55 / 51-53 53 840 330 850 220-240v, 50Hz Single 2.07 / 2.05 1.88 / 1.64 9.75 10.45 / 9.05 [16] 25 3 30 30 1.8 SUZ-KA71VA 53-55 / 51-53 58 840 330 850 220-240v, 50Hz Single 2.49 / 2.53 2.27 / 2.02 10.3 11.45 / 11.85 [16] 25 3 30 30 2.0 PUHZ-P100VHA2 PUHZ-P125VHA2 PUHZ-P140VHA2 54 / 50 75 950 330 + 30 943 220-240v, 50Hz Single 3.28 / 3.12 2.92 / 2.65 4 15.24 / 14.88 [28] 32 3 50 30 2.7 55 / 51 99 950 330 + 30 1350 220-240v, 50Hz Single 4.11 / 4.38 3.66 / 3.72 14 19.36 / 19.99 [28] 32 3 50 30 4.5 56 / 52 99 950 330 + 30 1350 220-240v, 50Hz Single 4.98 / 5.21 4.43 / 4.43 14 24.00 / 25.17 [29.5] 40 3 50 30 4.5

Notes: All units charged to 7m (35-71), 20m (100) and 30m (125-140) pipe length.

Page 74

Dimensions

INDOOR UNIT PEAD-RP35-60EA(2)


Upper View

>

Front View

>

Side View

>

Models Size 35-50 Size 60

A 772 1012

B 305 280

C 290

D 830 1070

E 804 1044

INDOOR UNIT PEAD-RP71-140EA(2)


Upper View

>

Side View Front View

>

>

Models Size 71 Size 100-125 Size 140

A 1012 1252 1552

B 280 360 460

C 290 370 470

D 1070 1310 1610

E 1044 1284 1584


Page 75

PEAD-RP Standard Inverter Heat Pump

Mr Slim Range 2008

PEAD-RP Heat Pump


Ceiling Concealed Ducted System
The Heat Pump system provides a low cost alternative to three phase Power Inverter systems.

Technical Information
PEAD-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) AIRFLOW (m3/min) PIPE SIZE mm(in) Lo-Hi Gas Liquid EXTERNAL STATIC PRESSURE (Pa) Lo-Hi NOISE (dBA) DIMENSIONS (mm) Lo-Hi (*3) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) - HRC (A) INTERCONNECTING CABLE No. CORES PEAD-RP100EA2 11.5 10.0 9.8 9.0 0.86 33.5-42 15.88 (5/8) 9.52 (3/8) 70-130*1 44-50 (46-52) 1415 740 325 65 Fed by Outdoor Unit Single 6 4 PEAD-RP125EA 14.3 12.3 12.2 11.05 0.82 33.5-42 15.88 (5/8) 9.52 (3/8) 70-130*2 44-50 (46-52) 1415 740 325 65 Fed by Outdoor Unit Single 6 4 PEAD-RP140EA 16.7 14.2 14.2 12.8 0.83 36.5-46 15.88 (5/8) 9.52 (3/8) 70-130*2 46-51 (47-53) 1715 740 325 70 Fed by Outdoor Unit Single 6 4

Notes: External static pressure - (100-140: 130Pa optional fan motor - *1 PAC-SK004MT-F, *2 PAC-SK003MT-F). *3 130Pa optional fan motor (100-140).

PUH-P - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 30m Heating/Cooling PUH-P100YHA 52 / 50 94 950 330 + 30 943 380-415v, 50Hz 3 3.42 / 3.69 3.04 / 3.14 45 7.8 / 8.01 [13.9] 20 5 50 50 4.4 PUH-P125YHA 52 / 50 131 950 330 + 30 1350 380-415v, 50Hz 3 4.32 / 4.41 3.85 / 3.75 70 9.19 / 9.41 [17.8] 20 5 50 50 5.0 PUH-P140YHA 53 / 51 131 950 330 + 30 1350 380-415v, 50Hz 3 5.28 / 5.63 4.70 / 4.79 85 11.14 / 11.24 [21.5] 25 5 50 50 5.0

Page 76

Dimensions

INDOOR UNIT PEAD-RP100-140EA(2)

Upper View

>

Models Size 100-125 Size 140

A 1252 1552

B 360 460

C 370 470

D 1310 1610

E 1284 1584

Front View

>

Side View

>
PEAD-RP Heat Pump
Page 77

Mr Slim Range 2008

PEA-RP-GA Power Inverter Heat Pump


Large Capacity Ceiling Concealed Ducted System
s s s

Twin, triple or quadruple configurations on one outdoor unit, utilising Mr Slim indoor units Static pressure of up to 150Pa Outdoor unit size reduced by approx 33%, with height being reduced by 66% (compared to previous model)

Technical Information
PEA-RP-GA - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) PEA-RP200GA 22.4 (9.5-25.0) 19.0 (9.0-22.4) 19.05 (8.1-21.25) 17.1 (8.3-21.15) 0.81 3.45 / 2.84 B / C 52-65 28.58 (1 1/8) 9.52 (3/8) 150 48-51 1400 634 400 70 380-415v, 50Hz 3 1.00 0.89 5.6 2.0 [2.4] 6 5 3 PEA-RP250GA 27.0 (12.5-31.5) 22.0 (11.2-28.0) 22.95 (10.65-26.8) 19.8 (10.3-25.2) 0.86 3.29 / 2.64 C / D 64-80 28.58 (1 1/8) 12.7 (1/2) 150 49-52 1600 634 400 77 380-415v, 50Hz 3 1.18 1.05 5.6 2.3 [2.8] 6 5 3 PEA-RP400GA 44.8 (18.0-50.0) 38.0 (18.0-44.8) 38.1 (15.3-42.5) 34.95 (16.55-41.2) 0.75 3.56 / 2.93 B / C 120 28.58 (1 1/8) x2 9.52 (3/8) x2 150 52 1947 764 595 130 380-415v, 50Hz 3 1.55 1.38 8.7 3.8 [4.6] 10 5 3 PEA-RP500GA 54.0 (25.0-63.0) 44.0 (22.4-56.0) 45.9 (21.25-53.55) 40.5 (20.6-51.5) 0.77 3.20 / 2.56 D / E 160 28.58 (1 1/8) x2 12.7 (1/2) x2 150 53 1947 764 595 133 380-415v, 50Hz 3 2.84 2.53 10 5.4 [6.5] 10 5 3

SHF (nominal) COP / EER (nominal) ENERGY LABEL AIRFLOW (m3/min) PIPE SIZE mm(in)

Heating/Cooling Lo-Hi Gas Liquid EXTERNAL STATIC PRESSURE (Pa) NOISE (dBA) Lo-Hi DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE POWER INPUT (kW) (nominal) (UK) STARTING CURRENT (A) RUNNING CURRENT (A) [Max] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores INTERCONNECTING CABLE No. CORES

PUHZ-RP-YHA2 - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Heating/Cooling Width Depth Height PUHZ-RP200YHA2 59 / 58 135 950 330+30 1350 380-415v, 50Hz 3 5.5 / 5.7 4.9 / 4.85 5 8.9 / 7.7 [19] 32 5 120 30 6.5 PUHZ-RP250YHA2 59 / 58 136 950 330+30 1350 330-415v, 50Hz 3 7.02 / 7.16 6.25 / 6.09 5 11.1 / 9.5 [21] 32 5 120 30 7.1 PUHZ-RP200YHA2 x2 59 / 58 135 950 330+30 1350 380-415v, 50Hz 3 5.5 / 5.7 4.9 / 4.85 5 8.9 / 7.7 [19] 32 5 120 per outdoor 30 6.5 PUHZ-RP250YHA2 x2 59 / 58 136 950 330+30 1350 330-415v, 50Hz 3 7.02 / 7.16 6.25 / 6.09 5 11.1 / 9.5 [21] 32 5 120 per outdoor 30 7.1

ELECTRICAL SUPPLY PHASE POWER INPUT (kW)

Heating/Cooling (nominal) Heating/Cooling (UK)

STARTING CURRENT (A) RUNNING CURRENT (A) [Max] Heating/Cooling FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 30m

Page 78

Dimensions

INDOOR UNIT PEA-RP200GA


Front View

>

Side View Upper View

>

>

INDOOR UNIT PEA-RP250GA


Front View

>

Side View Upper View

>

>

INDOOR UNIT PEA-RP400-500GA


Front View

>

Side View Upper View

>

>

Page 79

PEA-RP-GA Power Inverter Heat Pump

Mr Slim Range 2008

PEA-RP-GA Standard Inverter Heat Pump


Large Capacity Ceiling Concealed Ducted System
The Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the more expensive Power Inverter range.
s s

Twin, triple or quadruple configurations on one outdoor unit, utilising Mr Slim indoor units Static pressure of up to 150Pa

Technical Information
PEA-RP-GA - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) PEA-RP200GA 22.4 (9.5-25.0) 19.0 (9.0-22.4) 19.05 (8.1-21.25) 17.1 (8.3-21.15) 0.81 3.04 / 2.64 D / D 52-65 28.58 (1 1/8) 9.52 (3/8) 150 48-51 1400 634 400 70 380-415v, 50Hz 3 1.00 0.89 5.6 2.0 [2.4] 6 5 3 PEA-RP250GA 27.0 (12.5-31.5) 22.0 (11.2-28.0) 22.95 (10.65-26.8) 19.8 (10.3-25.2) 0.86 3.19 / 2.61 D / D 64-80 28.58 (1 1/8) 12.7 (1/2) 150 49-52 1600 634 400 77 380-415v, 50Hz 3 1.18 1.05 5.6 2.3 [2.8] 6 5 3 PEA-RP400GA 44.8 (19.0-50.0) 38.0 (18.0-44.8) 38.1 (16.15-42.5) 34.95 (16.55-41.2) 0.75 3.14 / 2.72 D / D 120 28.58 (1 1/8) x2 9.52 (3/8) x2 150 52 1947 764 595 130 380-415v, 50Hz 3 1.55 1.38 8.7 3.8 [4.6] 10 5 3 PEA-RP500GA 54.0 (25.0-63.0) 44.0 (22.4-56.0) 45.9 (21.25-53.55) 40.5 (20.6-51.5) 0.77 3.10 / 2.53 D / E 160 28.58 (1 1/8) x2 12.7 (1/2) x2 150 53 1947 764 595 133 380-415v, 50Hz 3 2.84 2.53 10 5.4 [ 6.5] 10 5 3

SHF (nominal) COP / EER (nominal) ENERGY LABEL AIRFLOW (m3/min) PIPE SIZE mm(in)

Heating/Cooling Lo-Hi Gas Liquid EXTERNAL STATIC PRESSURE (Pa) NOISE (dBA) Lo-Hi DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE POWER INPUT (kW) (nominal) (UK) STARTING CURRENT (A) RUNNING CURRENT (A) [Max] FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores INTERCONNECTING CABLE No. CORES

PUHZ-P-YHA - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Heating/Cooling Width Depth Height PUHZ-P200YHA 59 / 59 126 950 330+30 1350 380-415v, 50Hz 3 6.36 / 6.21 5.66 / 5.28 5 9.88 / 9.47 [ 19 ] 32 5 70 30 5.8 PUHZ-P250YHA 59 / 59 133 950 330+30 1350 330-415v, 50Hz 3 7.29 / 7.26 6.49 / 6.17 5 12.0 / 11.0 [ 21 ] 32 5 70 30 7.1 PUHZ-P200YHA x2 59 / 59 126 950 330+30 1350 380-415v, 50Hz 3 6.36 / 6.21 5.66 / 5.28 5 9.88 / 9.47 [ 19 ] 32 5 70 per outdoor 30 5.8 PUHZ-P250YHA x2 59 / 59 133 950 330+30 1350 330-415v, 50Hz 3 7.29 / 7.26 6.49 / 6.17 5 12.0 / 11.0 [ 21 ] 32 5 70 per outdoor 30 7.1

ELECTRICAL SUPPLY PHASE POWER INPUT (kW)

Heating/Cooling (nominal) Heating/Cooling (UK)

STARTING CURRENT (A) RUNNING CURRENT (A) [Max] Heating/Cooling FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 30m

Page 80

Dimensions

INDOOR UNIT PEA-RP200GA


Front View

>

Side View Upper View

>

>

INDOOR UNIT PEA-RP250GA


Front View

>

Side View Upper View

>

>

INDOOR UNIT PEA-RP400-500GA


Front View

>

Side View Upper View

>

>

Page 81

PEA-RP-GA Standard Inverter Heat Pump

Mr Slim Range 2008

SLZ-KA-VA Inverter Heat Pump


600x600 4-Way Blow Ceiling Cassette System
The SLZ-KA-VA series is perfect for both residential and small business applications, as it offers inverter technology alongside quiet operation. The compact size of this unit is ideal for 600 by 600mm ceilings and with a depth of 208mm, this lightweight unit makes installation a breeze. This unit also comes complete with a long life filter that will last for approximately 2,500 hours.

Note: Optional interfaces for M-NET connectivity (MAC-399IF) and group control, fault/run (MAC-397IF) are available. Please see accessories / optional extras section.

Technical Information
SLZ-KA50VA 5.0 (0.9-6.5) 4.6 (1.1-5.2) 4.15 (0.75-5.4) 4.55 (1.1-5.15) 0.68 3.23 / 2.82 C/C 8-9-11 12.7 (1/2) 6.35 (1/4) 30-34-39 570 (650) 570 (650) 208 (20) 16.5 3 Fed by Outdoor Unit Single 6 4

SLZ-KA-VA - INDOOR UNITS


MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) COP / EER (nominal) ENERGY LABEL AIRFLOW (m3/min) PIPE SIZE mm(in) Heating/Cooling Lo-Mi-Hi Gas Liquid NOISE (dBA) Lo-Mi-Hi SLZ-KA25VA 3.0 (0.9-4.5) 2.5 (0.9-3.2) 2.5 (0.75-3.75) 2.5 (0.9-3.15) 0.86 3.61 / 3.62 A /A 8-9-10 9.52 (3/8) 6.35 (1/4) 28-31-37 570 (650) 570 (650) 208 (20) 16.5 3 Fed by Outdoor Unit Single 6 4 SLZ-KA35VA 4.0 (0.9-5.0) 3.5 (1.0-3.9) 3.3 (0.75-4.15) 3.45 (1.0-3.85) 0.77 3.64 / 3.30 A /A 8-9-11 9.52 (3/8) 6.35 (1/4) 29-33-38 570 (650) 570 (650) 208 (20) 16.5 3 Fed by Outdoor Unit Single 6 4

DIMENSIONS (mm) (grille) Width Depth Height WEIGHT (kg) Unit Grille ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) - HRC (A) INTERCONNECTING CABLE No. CORES

SUZ-KA-VA - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) (Lo-Hi) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. CORES MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 7m Heating/Cooling SUZ-KA25VA 46 / 46 33 800 285 550 220-240v, 50Hz 0.83 / 0.69 0.76 / 0.55 3.65 4.0 / 3.4 [8.16] 16 3 20 12 0.9 SUZ-KA35VA 48 / 47 37 800 285 550 220-240v, 50Hz 1.10 / 1.06 1.00 / 0.85 4.75 5.15 / 4.95 [9.18] 16 3 20 12 1.05 SUZ-KA50VA 53-55 / 51-53 53 840 330 850 220-240v, 50Hz 1.55 / 1.63 1.41 / 1.30 6.75 7.0 / 7.4 [16] 25 3 30 30 1.6

Page 82

Dimensions

INDOOR UNIT SLZ-KA25-50VA

Lower View

>

Side View

>

Page 83

SLZ-KA-VA Inverter Heat Pump

Mr Slim Range 2008

PLA-RP Power Inverter Heat Pump


4-Way Blow Ceiling Cassette System
s s s s

Airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed Reduced draft air distribution, with independent vane control Filter lowering operation down to 4m (optional PLP-6BAJ grille required) Optional I See Sensor' for energy saving and smooth temperature control throughout the room

Technical Information
PLA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) COP / EER (nominal) ENERGY LABEL AIRFLOW (m3/min) PIPE SIZE mm(in) NOISE (dBA) DIMENSIONS (mm) (Grille) WEIGHT (kg) ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) - HRC (A) INTERCONNECTING CABLE No. CORES GRILLE REFERENCE WIRED REMOTE CONTROLLER REFERENCE [3 Phase] Heating/Cooling Lo-Mi1-Mi2-Hi Gas Liquid Lo-Mi1-Mi2-Hi Width Depth Height Unit Panel PLA-RP35BA 4.1 (1.6-5.2) 3.6 (1.6-4.5) 3.5 (1.35-4.4) 3.25 (1.45-4.05) 0.84 3.66 / 3.36 A /A 11-12-13-15 12.7 (1/2) 6.35 (1/4) 27-28-29-31 840 (950) 840 (950) 258 (35) 22 6 Single 6 4 PLP-6BA PAR-21MAA PLA-RP50BA 6.0 (2.5-7.3) 5.0 (2.3-5.6) 5.1 (2.15-6.2) 4.5 (2.05-5.05) 0.81 3.61 / 3.23 A /A 12-14-16-18 12.7 (1/2) 6.35 (1/4) 28-29-31-32 840 (950) 840 (950) 258 (35) 22 6 Single 6 4 PLP-6BA PAR-21MAA PLA-RP60BA 7.0 (2.8-8.2) 6.0 (2.7-6.7) 5.95 (2.4-6.95) 5.4 (2.45-6.05) 0.76 3.78 / 3.64 A /A 12-14-16-18 15.88 (5/8) 9.52 (3/8) 28-29-31-32 840 (950) 840 (950) 258 (35) 23 6 Single 6 4 PLP-6BA PAR-21MAA PLA-RP71BA2 8.0 (3.5-10.2) 7.1 (3.3-8.1) 6.8 (3.0-8.65) 6.4 (2.95-7.3) 0.81 4.21 / 3.66 A /A 14-16-18-21 15.88 (5/8) 9.52 (3/8) 28-30-32-34 840 (950) 840 (950) 258 (35) 23 6 Single 6 4 PLP-6BA PAR-21MAA PLA-RP100BA2 PLA-RP125BA2 11.2 (4.5-14.0) 10.0 (4.9-11.4) 9.5 (3.85-11.9) 9.0 (4.4-10.25) 0.79 A /A 20-23-26-30 15.88 (5/8) 9.52 (3/8) 32-34-37-40 840 (950) 840 (950) 298 (35) 27 6 Single 6 4 PLP-6BA PAR-21MAA 14.0 (5.0-16.0) 12.5 (5.5-14.0) 11.9 (4.25-13.6) 11.25 (4.95-12.6) 0.81 A /A 22-25-28-31 15.88 (5/8) 9.52 (3/8) 34-36-39-41 840 (950) 840 (950) 298 (35) 27 6 Single 6 4 PLP-6BA PAR-21MAA PLA-RP140BA 16.0 (5.0-18.0) 14.0 (5.5-15.3) 13.6 (4.25-15.3) 12.6 (4.95-13.75) 0.71 3.61 / 3.01 A/B 24-26-29-32 15.88 (5/8) 9.52 (3/8) 36-39-42-44 840 (950) 840 (950) 298 (35) 27 6 Fed by Outdoor Unit Single 6 4 PLP-6BA PAR-21MAA

4.41/4.10 [4.31/4.00] 3.99/3.35 [3.92/3.30]

Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit

PUHZ-RP - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) [3 Phase] STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Single Phase Heating/Cooling [MAX] 3 Phase FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 30m Heating/Cooling (UK) Heating/Cooling PUHZ-RP35VHA3 PUHZ-RP50VHA3 PUHZ-RP60VHA3 PUHZ-RP71VHA3 PUHZ-RP100VHA3/YHA3 PUHZ-RP125VHA2/YHA2 PUHZ-RP140VHA2/YHA2 46 / 44 42 800 300 + 23 600 220-240v, 50Hz Single 1.12 / 1.07 1.00 / 0.91 5 4.37 / 4.23 [13] 16 3 50 30 2.5 46 / 44 42 800 300 + 23 600 220-240v, 50Hz Single 1.66 / 1.55 1.48 / 1.32 5 6.76 / 6.52 [13] 16 3 50 30 2.5 48 / 47 68 950 330 + 30 943 220-240v, 50Hz Single 1.85 / 1.65 1.65 / 1.40 5 7.79 / 6.97 [19] 25 3 50 30 3.5 48 / 47 68 950 330 + 30 943 220-240v, 50Hz Single 1.90 / 1.94 1.69 / 1.65 5 10.17 / 8.55 [19] 25 3 50 30 3.5 51 / 49 116 / 130 950 330 + 30 1350 Single / 3 52 / 50 116 / 130 950 330 + 30 1350 Single / 3 52 / 50 116 / 130 950 330 + 30 1350 Single / 3 4.43 / 4.65 3.94 / 3.95 5 20.92 / 20.72 [29.5] 7.37 / 7.53 [13] 40 / 16 3/5 75 30 5.0

220-240v, 50Hz /380-415,50Hz 220-240v, 50Hz/380-415,50Hz 220-240v, 50Hz / 380-415,50Hz


2.54/2.44 [2.60/2.50] 3.51/3.73[3.57/3.79] 2.26/2.07 [2.31/2.13] 3.12/3.17 [3.18/3.22]

5 13.26 / 13.47 [28] 4.90 / 5.02 [13] 32 / 16 3/5 75 30 5.0

5 16.92 / 16.53 [28] 6.14 / 6.04 [13] 32 / 16 3/5 75 30 5.0

Page 84

Dimensions

INDOOR UNIT PLA-RP35-140BA(2)


Upper View

>

Lower View

>

Side View

>

Models Size 35-71 Size 100-140

A 241 281

B 258 298

Page 85

PLA-RP Power Inverter Heat Pump

Mr Slim Range 2008

PLA-RP Standard Inverter Heat Pump


4-Way Blow Ceiling Cassette System
The new Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the more expensive Power Inverter range.
s s s s

Airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed Reduced draft air distribution, with independent vane control Filter lowering operation down to 4m (optional PLP-6BAJ grille required) Optional I See Sensor for energy saving and smooth temperature control throughout the room

Technical Information
PLA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) COP / EER (nominal) ENERGY LABEL AIRFLOW (m3/min) PIPE SIZE mm(in) NOISE (dBA) DIMENSIONS (mm) (Grille) WEIGHT (kg) ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) - HRC (A) INTERCONNECTING CABLE No. CORES GRILLE REFERENCE WIRED REMOTE CONTROLLER REFERENCE Heating/Cooling Lo-Mi1-Mi2-Hi Gas Liquid Lo-Mi1-Mi2-Hi Width Depth Height Unit Panel PLA-RP35BA 4.1 (0.9-5.0) 3.5 (1.0-3.9) 3.4 (0.75-4.15) 3.45 (1.0-3.85) 0.84 3.69 / 3.21 A /A 11-12-13-15 9.52 (3/8) 6.35 (1/4) 27-28-29-31 840 (950) 840 (950) 258 (35) 22 6 Single 6 4 PLP-6BA PAR-21MAA PLA-RP50BA 6.0 (0.9-7.2) 5.0 (1.1-5.6) 5.0 (0.75-6.0) 4.95 (1.1-5.55) 0.81 3.30 / 2.81 C/C 12-14-16-18 12.7 (1/2) 6.35 (1/4) 28-29-31-32 840 (950) 840 (950) 258 (35) 22 6 Single 6 4 PLP-6BA PAR-21MAA PLA-RP60BA 6.9 (0.9-8.0) 5.7 (1.1-6.3) 5.75 (0.75-6.65) 5.65 (1.1-6.25) 0.76 3.27 / 2.94 C/C 12-14-16-18 15.88 (5/8) 6.35 (1/4) 28-29-31-32 840 (950) 840 (950) 258 (35) 23 6 Single 6 4 PLP-6BA PAR-21MAA PLA-RP71BA 8.0 (0.9-10.2) 7.1 (0.9-8.1) 6.65 (0.75-8.5) 7.05 (0.9-8.05) 0.73 3.21 / 2.81 C/C 14-16-18-21 15.88 (5/8) 9.52 (3/8) 28-30-32-34 840 (950) 840 (950) 258 (35) 23 6 Single 6 4 PLP-6BA PAR-21MAA PLA-RP100BA 11.2 (4.5-12.5) 9.4 (4.9-11.2) 9.5 (3.85-10.65) 8.45 (4.4-10.1) 0.74 3.41 / 3.01 B/B 20-23-26-30 15.88 (5/8) 9.52 (3/8) 32-34-37-40 840 (950) 840 (950) 298 (35) 25 6 Single 6 4 PLP-6BA PAR-21MAA PLA-RP125BA 14.0 (5.0-16.0) 12.3 (5.5-14.0) 11.9 (4.25-13.6) 11.05 (4.95-12.6) 0.71 3.41 / 3.01 B/B 22-25-28-31 15.88 (5/8) 9.52 (3/8) 34-36-39-41 840 (950) 840 (950) 298 (35) 25 6 Single 6 4 PLP-6BA PAR-21MAA PLA-RP140BA 16.0 (5.0-18.0) 13.6 (5.5-15.0) 13.6 (4.25-15.3) 12.25 (4.95-13.5) 0.71 3.21 / 2.61 C/D 24-26-29-32 15.88 (5/8) 9.52 (3/8) 36-39-42-44 840 (950) 840 (950) 298 (35) 27 6 Single 6 4 PLP-6BA PAR-21MAA

Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit

SUZ-KA / PUHZ-P - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) (Lo-Hi) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) Heating/Cooling SUZ-KA35VA 48 / 47 37 800 285 550 220-240v, 50Hz Single 1.11 / 1.09 1.01 / 0.87 4.75 4.89 / 4.77 [9.18] 16 3 20 12 1.05 SUZ-KA50VA 53-55 / 51-53 53 840 330 850 220-240v, 50Hz Single 1.82 / 1.78 1.62 / 1.42 6.75 6.64 / 7.11 [16] 25 3 30 30 1.6 SUZ-KA60VA 53-55 / 51-53 53 840 330 850 220-240v, 50Hz Single 2.11 / 1.94 1.92 / 1.55 9.75 10.04 / 8.71 [16] 25 3 30 30 1.8 SUZ-KA71VA 53-55 / 51-53 58 840 330 850 220-240v, 50Hz Single 2.49 / 2.53 2.27 / 2.02 10.3 10.33 / 10.81 [16] 25 3 30 30 2.0 PUHZ-P100VHA2 PUHZ-P125VHA2 PUHZ-P140VHA2 54 / 50 75 950 330 + 30 943 220-240v, 50Hz Single 3.28 / 3.12 2.92 / 2.65 4 13.49 / 13.20 [28] 32 3 50 30 2.7 55 / 51 99 950 330 + 30 1350 220-240v, 50Hz Single 4.11 / 4.09 3.66 / 3.48 14 17.68 / 18.37 [28] 32 3 50 30 4.5 56 / 52 99 950 330 + 30 1350 220-240v, 50Hz Single 4.98 / 5.21 4.43 / 4.43 14 22.31 / 23.55 [29.5] 40 3 50 30 4.5

Notes: All units charged to 7m (35-71), 20m (100) and 30m (125-140) pipe length.

Page 86

Dimensions

INDOOR UNIT PLA-RP35-140BA


Upper View

>

Lower View

>

Side View

>

Models Size 35-71 Size 100-140

A 241 281

B 258 298

Page 87

PLA-RP Standard Inverter Heat Pump

Mr Slim Range 2008

PLA-RP Heat Pump


4-Way Blow Ceiling Cassette System
The Heat Pump system provides a low cost alternative to three phase Power Inverter systems.
s s
s s

Airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed Reduced draft air distribution, with independent vane control
Filter lowering operation down to 4m (optional PLP-6BAJ grille required) Optional I See Sensor' for energy saving and smooth temperature control throughout the room

Technical Information
PLA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) AIRFLOW (m3/min) PIPE SIZE mm(in) NOISE (dBA) Lo-Mi1-Mi2-Hi Gas Liquid Lo-Mi1-Mi2-Hi Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) - HRC (A) INTERCONNECTING CABLE No. CORES GRILLE REFERENCE WIRED REMOTE CONTROLLER REFERENCE Unit Panel DIMENSIONS (mm) (grille) Width PLA-RP100BA 11.5 10.0 9.8 9.0 0.74 20-23-26-30 15.88 (5/8) 9.52 (3/8) 32-34-37-40 840 (950) 840 (950) 298 (35) 25 6 Fed by Outdoor Unit Single 6 4 PLP-6BA PAR-21MAA PLA-RP125BA 14.3 12.3 12.15 11.05 0.71 22-25-28-31 15.88 (5/8) 9.52 (3/8) 34-36-39-41 840 (950) 840 (950) 298 (35) 25 6 Fed by Outdoor Unit Single 6 4 PLP-6BA PAR-21MAA PLA-RP140BA 17.0 14.2 14.45 12.8 0.71 24-26-29-32 15.88 (5/8) 9.52 (3/8) 36-39-42-44 840 (950) 840 (950) 298 (35) 27 6 Fed by Outdoor Unit Single 6 4 PLP-6BA PAR-21MAA

PUH-P - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 30m Heating/Cooling PUH-P100YHA 52 / 50 94 950 330 + 30 943 380-415,50Hz 3 3.40 / 3.53 3.03 / 3.00 45 6.05 / 6.33 [12.2] 20 5 50 50 4.4 PUH-P125YHA 52 / 50 131 950 330 + 30 1350 380-415v, 50Hz 3 4.23 / 4.36 3.76 / 3.71 70 7.51 / 7.79 [16.1] 20 5 50 50 5.0 PUH-P140YHA 53 / 51 131 950 330 + 30 1350 380-415v, 50Hz 3 5.35 / 5.41 4.76 / 4.60 85 9.45 / 9.62 [19.8] 25 5 50 50 5.0

Notes: Optional infra-red grille and remote controller available.

Page 88

Dimensions

INDOOR UNIT PLA-RP100-140BA


Upper View

>

Lower View

>

Side View

>

Models Size 35-71 Size 100-140

A 241 281

B 258 298

Page 89

PLA-RP Heat Pump

Mr Slim Range 2008

PCA-RP Power Inverter Heat Pump


Ceiling Suspended System
s s

Indoor unit designed for direct ceiling suspension Flush to wall installation for concealment of service connections Electronic control includes learning defrost, fault finding diagnostics, low ambient fan speed control and anti-phase/ single phase protection

Technical Information
PCA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) COP / EER (nominal) ENERGY LABEL AIRFLOW (m3/min) PIPE SIZE mm(in) NOISE (dBA) DIMENSIONS (mm) Heating/Cooling Lo-Mi1-Mi2-Hi Gas Liquid Lo-Mi1-Mi2-Hi Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) - HRC (A) INTERCONNECTING CABLE No. CORES PCA-RP50GA2 6.0 (2.5-7.3) 5.0 (2.3-5.6) 5.1 (2.15-6.2) 4.5 (2.05-5.05) 0.88 3.41 / 3.01 B/B 14-15-16-18 12.7 (1/2) 6.35 (1/4) 37-39-41-43 1310 680 210 34 Fed by Outdoor Unit Single 6 4 PCA-RP60GA 7.0 (2.8-8.2) 6.0 (2.7-6.7) 5.95 (2.4-6.95) 5.4 (2.45-6.05) 0.86 3.45 / 3.68 B /A 14-15-16-18 15.88 (5/8) 9.52 (3/8) 37-39-41-43 1310 680 210 34 Fed by Outdoor Unit Single 6 4 PCA-RP71GA 7.6 (3.5-10.2) 7.1 (3.3-8.1) 6.45 (3.0-8.65) 6.4 (2.95-7.3) 0.74 3.41 / 3.32 B /A 14-15-16-18 15.88 (5/8) 9.52 (3/8) 37-39-41-43 1310 680 210 34 Fed by Outdoor Unit Single 6 4 PCA-RP100GA 11.2 (4.5-14.0) 10.0 (4.9-11.4) 9.5 (3.85-11.9) 9.0 (4.4-10.25) 0.75 3.44 / 3.42 B /A 20-21-23-25 15.88 (5/8) 9.52 (3/8) 40-41-43-45 1310 680 270 37 Fed by Outdoor Unit Single 6 4 PCA-RP125GA 14.0 (5.0-16.0) 12.5 (5.5-14.0) 11.9 (4.25-13.6) 11.25 (4.95-12.6) 0.77 3.41 / 3.22 B /A 27-30-32-34 15.88 (5/8) 9.52 (3/8) 41-43-45-46 1620 680 270 43 Fed by Outdoor Unit Single 6 4 PCA-RP140GA 16.0 (5.0-18.0) 14.0 (5.5-15.3) 13.6 (4.25-15.3) 12.6 (4.95-13.75) 0.75 3.48 / 3.01 B/B 27-30-32-34 15.88 (5/8) 9.52 (3/8) 42-44-46-48 1620 680 270 45 Fed by Outdoor Unit Single 6 4

PUHZ-RP - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Single Phase Heating/Cooling [MAX] 3 Phase FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 30m Heating/Cooling PUHZ-RP50VHA3 46 / 44 42 800 300 + 23 600 220-240v, 50Hz Single 1.76 / 1.66 1.57 / 1.41 5 7.0 / 6.69 [13] 16 3 50 30 2.5 PUHZ-RP60VHA3 48 / 47 68 950 330 + 30 943 220-240v, 50Hz Single 2.03 / 1.63 1.81 / 1.39 5 8.03 / 7.14 [19] 25 3 50 30 3.5 PUHZ-RP71VHA3 PUHZ-RP100VHA3/YHA3 PUHZ-RP125VHA2/YHA2 PUHZ-RP140VHA2/YHA2 48 / 47 68 950 330 + 30 943 220-240v, 50Hz Single 2.23 / 2.14 1.98 / 1.82 5 10.27 / 8.57 [19] 25 3 50 30 3.5 51 / 49 116 / 130 950 330 + 30 1350 Single / 3 3.26 / 2.92 2.90 / 2.48 5 13.08 / 13.22 [28] 4.72 / 4.77 [13] 32 / 16 3/5 75 30 5.0 52 / 50 116 / 130 950 330 + 30 1350 Single / 3 4.11 / 3.88 3.66 / 3.30 5 16.99 / 16.54 [28] 6.21 / 6.05 [13] 32 / 16 3/5 75 30 5.0 52 / 50 116 / 130 950 330 + 30 1350 Single / 3 4.60 / 4.65 4.09 / 3.95 5 20.93 / 20.66 [29.5] 7.47 / 7.38 [13] 40 / 16 3/5 75 30 5.0

220-240v, 50Hz / 380-415,50Hz 220-240v, 50Hz / 380-415,50Hz 220-240v, 50Hz / 380-415,50Hz

Page 90

Dimensions

INDOOR UNIT PCA-RP50-71GA(2)


Lower View

>

Front View

>

Side View

>

INDOOR UNIT PCA-RP100GA


Lower View

>

Front View

>

Side View

>

INDOOR UNIT PCA-RP125-140GA


Lower View

Page 91

PCA-RP Power Inverter Heat Pump

>

Front View

>

Side View

>

Mr Slim Range 2008

PCA-RP Standard Inverter Heat Pump


Ceiling Suspended System
The new Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the more expensive Power Inverter range.
s s

Indoor unit designed for direct ceiling suspension Flush to wall installation for concealment of service connections Electronic control includes learning defrost, fault finding diagnostics, low ambient fan speed control and anti-phase / single phase protection

Technical Information
PCA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) COP / EER (nominal) ENERGY LABEL AIRFLOW (m3/min) PIPE SIZE mm(in) NOISE (dBA) DIMENSIONS (mm) Heating/Cooling Lo-Mi1-Mi2-Hi Gas Liquid Lo-Mi1-Mi2-Hi Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) - HRC (A) INTERCONNECTING CABLE No. CORES PCA-RP50GA2 6.0 (0.9-7.2) 5.0 (1.1-5.6) 5.0 (0.75-6.0) 4.95 (1.1-5.55) 0.81 3.41 / 2.81 B/C 14-15-16-18 12.7 (1/2) 6.35 (1/4) 37-39-41-43 1310 680 210 34 Fed by Outdoor Unit Single 6 4 PCA-RP60GA 6.9 (0.9-8.0) 5.5 (1.1-6.3) 5.75 (0.75-6.65) 5.45 (1.1-6.25) 0.79 3.37 / 2.86 C/C 14-15-16-18 15.88 (5/8) 6.35 (1/4) 37-39-41-43 1310 680 210 34 Fed by Outdoor Unit Single 6 4 PCA-RP71GA 8.0 (0.9-10.2) 7.1 (0.9-8.1) 6.65 (0.75-8.5) 7.05 (0.9-8.05) 0.71 3.21 / 2.81 C/C 14-15-16-18 15.88 (5/8) 9.52 (3/8) 37-39-41-43 1310 680 210 34 Fed by Outdoor Unit Single 6 4 PCA-RP100GA 11.2 (4.5-12.5) 9.4 (4.9-11.2) 9.5 (3.85-10.65) 8.45 (4.4-10.1) 0.77 3.21 / 2.81 C/C 20-21-23-25 15.88 (5/8) 9.52 (3/8) 40-41-43-45 1310 680 270 37 Fed by Outdoor Unit Single 6 4 PCA-RP125GA 14.0 (5.0-16.0) 12.3 (5.5-14.0) 11.9 (4.25-13.6) 11.05 (4.95-12.6) 0.78 2.81 / 2.81 D/C 27-30-32-34 15.88 (5/8) 9.52 (3/8) 41-43-45-46 1620 680 270 43 Fed by Outdoor Unit Single 6 4 PCA-RP140GA 16.0 (5.0-18.0) 13.6 (5.5-15.0) 13.6 (4.25-15.3) 12.25 (4.95-13.5) 0.76 3.21 / 2.61 C/D 27-30-32-34 15.88 (5/8) 9.52 (3/8) 42-44-46-48 1620 680 270 45 Fed by Outdoor Unit Single 6 4

SUZ-KA / PUHZ-P - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) (Lo-Hi) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) Heating/Cooling SUZ-KA50VA 53-55 / 51-53 53 840 330 850 220-240v, 50Hz Single 1.76 / 1.78 1.60 / 1.42 6.75 6.88 / 7.28 [16] 25 3 30 30 1.6 SUZ-KA60VA 53-55 / 51-53 53 840 330 850 220-240v, 50Hz Single 2.05 / 1.92 1.87 / 1.54 9.75 10.28 / 8.88 [16] 25 3 30 30 1.8 SUZ-KA71VA 53-55 / 51-53 58 840 330 850 220-240v, 50Hz Single 2.49 / 2.53 2.27 / 2.02 10.3 10.43 / 10.83 [16] 25 3 30 30 2.0 PUHZ-P100VHA2 54 / 50 75 950 330 + 30 943 220-240v, 50Hz Single 3.49 / 3.35 3.11 / 2.85 4 13.31 / 12.95 [28] 32 3 50 30 2.7 PUHZ-P125VHA2 55 / 51 99 950 330 + 30 1350 220-240v, 50Hz Single 4.98 / 4.38 4.43 / 3.72 14 17.75 / 18.38 [28] 32 3 50 30 4.5 PUHZ-P140VHA2 56 / 52 99 950 330 + 30 1350 220-240v, 50Hz Single 4.98 / 5.21 4.43 / 4.43 14 22.32 / 23.49 [29.5] 40 3 50 30 4.5

Notes: All units charged to 7m (50-71), 20m (100) and 30m (125-140) pipe length.

Page 92

Dimensions

INDOOR UNIT PCA-RP50-71GA(2)


Lower View

>

Front View

>

Side View

>

INDOOR UNIT PCA-RP100GA


Lower View

>

Front View

>

Side View

>

Lower View

>

Front View

>

Side View

>

Page 93

PCA-RP Standard Inverter Heat Pump

INDOOR UNIT PCA-RP125-140GA

Mr Slim Range 2008

PCA-RP Heat Pump


Ceiling Suspended System
The Heat Pump system provides a low cost alternative to three phase Power Inverter systems.
s s s

Indoor unit designed for direct ceiling suspension Flush to wall installation for concealment of service connections Electronic control includes learning defrost, fault finding diagnostics, low ambient fan speed control and anti-phase / single phase protection

Technical Information
PCA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) AIRFLOW (m3/min) PIPE SIZE mm(in) NOISE (dBA) DIMENSIONS (mm) Lo-Mi1-Mi2-Hi Gas Liquid Lo-Mi1-Mi2-Hi Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) - HRC (A) INTERCONNECTING CABLE No. CORES PCA-RP100GA 11.5 9.8 9.8 8.8 0.75 20-21-23-25 15.88 (5/8) 9.52 (3/8) 40-41-43-45 1310 680 270 37 Fed by Outdoor Unit Single 6 4 PCA-RP125GA 14.3 12.3 12.15 11.05 0.77 27-30-32-34 15.88 (5/8) 9.52 (3/8) 41-43-45-46 1620 680 270 43 Fed by Outdoor Unit Single 6 4 PCA-RP140GA 17.0 14.2 14.45 12.8 0.75 27-30-32-34 15.88 (5/8) 9.52 (3/8) 42-44-46-48 1620 680 270 45 Fed by Outdoor Unit Single 6 4

PUH-P - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 30m Heating/Cooling PUH-P100YHA 52 / 50 94 950 330 + 30 943 380-415v, 50Hz 3 3.45 / 3.55 3.07 / 3.02 45 5.87 / 6.08 [12.0] 20 5 50 50 4.4 PUH-P125YHA 52 / 50 131 950 330 + 30 1350 380-415v, 50Hz 3 4.72 / 4.52 4.20 / 3.84 70 7.58 / 7.8 [16.2] 20 5 50 50 5.0 PUH-P140YHA 53 / 51 131 950 330 + 30 1350 380-415v, 50Hz 3 5.22 / 5.44 4.65 / 4.62 85 9.46 / 9.56 [19.8] 25 5 50 50 5.0

Page 94

Dimensions

INDOOR UNIT PCA-RP100GA

Front View

>

Side View

>

Lower View

>

INDOOR UNIT PCA-RP125-140GA

Front View

>

Side View

>

Lower View

>

Page 95

PCA-RP Heat Pump

Mr Slim Range 2008

PCA-RP-HA Power Inverter Heat Pump


Stainless Steel Ceiling Suspended System
The PCA-RP-HA series is a ceiling suspended unit ideal for use in kitchen environments. The external casing is made of durable stainless steel that is resistant to oil and smoke, ensuring that the unit can be easily cleaned at all times.
s s

High performance oil mist filter Easy maintenance - fan casing can be separated into different sections allowing easy cleaning. The drain pan can also be cleaned easily on-site as the pipe connector can be quickly removed Optional decoration covers

Technical Information
PCA-RP-HA - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) COP / EER (nominal) ENERGY LABEL AIRFLOW (m3/min) PIPE SIZE mm(in) NOISE (dBA) DIMENSIONS (mm) Heating/Cooling Lo-Hi Gas Liquid Lo-Hi Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) - HRC (A) INTERCONNECTING CABLE No. CORES PCA-RP71HA 7.6 (3.5-10.2) 7.1 (3.3-8.1) 6.45 (3.0-8.65) 6.4 (2.95-7.3) 0.74 3.41 / 3.21 B /A 17-19 15.88 (5/8) 9.52 (3/8) 34-38 1136 650 280 41 Fed by Outdoor Unit Single 6 4 PCA-RP125HA 13.8 (5.0-16.0) 12.5 (5.5-14.0) 11.75 (4.25-13.6) 11.25 (4.95-12.6) 0.77 3.41 / 3.22 B /A 30-38 15.88 (5/8) 9.52 (3/8) 44-50 1520 650 280 56 Fed by Outdoor Unit Single 6 4

PUHZ-RP - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (KW) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Single Phase Heating/Cooling [MAX] 3 Phase FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 30m Heating/Cooling (nominal) Heating/Cooling (UK) Heating/cooling PUHZ-RP71VHA3 48 / 47 68 950 330 + 30 943 220-240v, 50Hz Single 2.23 / 2.21 1.98 / 1.88 5 10.17 / 8.47 [19] 25 3 50 30 3.5 PUHZ-RP125VHA2/YHA2 52 / 50 116 / 130 950 330 + 30 1350 220-240v, 50Hz / 380-415v, 50Hz Single / 3 4.05 / 3.88 3.60 / 3.30 5 17.17 / 16.72 [28] 6.39 / 6.23 [13] 32 / 16 3/5 75 30 5.0

Page 96

Dimensions

INDOOR UNIT PCA-RP71HA


Front View

>
1224 1180 110 102

986 1136

75

Lower View

>
Side View

>

650

258

1136

280

650

INDOOR UNIT PCA-RP125HA


Front View

>
1608 1564

1370 1520

75

Lower View

>
Side View

>

1520

650

Page 97

PCA-RP-HA Power Inverter Heat Pump

650

110 102

258

280

Mr Slim Range 2008

PCA-RP-HA Standard Inverter Heat Pump


Stainless Steel Ceiling Suspended System
The new Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the more expensive Power Inverter range.
s s

High performance oil mist filter Easy maintenance - fan casing can be separated into different sections allowing easy cleaning. The drain pan can also be cleaned easily on-site as the pipe connector can be quickly removed Optional decoration covers

Technical Information
PCA-RP-HA - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) COP / EER (nominal) ENERGY LABEL AIRFLOW (m3/min) PIPE SIZE mm(in) NOISE (dBA) DIMENSIONS (mm) Heating/Cooling Lo-Hi Gas Liquid Lo-Hi Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) - HRC (A) INTERCONNECTING CABLE No. CORES PCA-RP125HA 13.8 (5.0-16.0) 12.3 (5.5-14.0) 11.75 (4.25-13.6) 11.05 (4.95-12.6) 0.78 3.21 / 2.81 C/C 30-38 15.88 (5/8) 9.52 (3/8) 44-50 1520 650 280 56 Fed by Outdoor Unit Single 6 4

PUHZ-P - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (KW) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) [MAX] FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 30m Heating/Cooling Heating/Cooling (nominal) Heating/Cooling (UK) Heating/cooling PUHZ-P125VHA2 55 / 51 99 950 330 + 30 1350 220-240v, 50Hz Single 4.30 / 4.38 3.83 / 3.72 14 17.93 / 18.56 [28] 32 3 50 30 4.5

Page 98

Dimensions

INDOOR UNIT PCA-RP125HA


Front View

>
1608 1564 110 102

1370 1520

75

Lower View

>
Side View

>

650

1520

258

280

650

Page 99

PCA-RP-HA Standard Inverter Heat Pump

Mr Slim Range 2008

PCA-RP-HA Heat Pump


Stainless Steel Ceiling Suspended System
The Heat Pump system provides a low cost alternative to three phase Power Inverter systems. The PCA-RP-HA series is a ceiling suspended unit ideal for use in kitchen environments. The external casing is made of durable stainless steel that is resistant to oil and smoke, ensuring that the unit can be easily cleaned at all times.
s s

High performance oil mist filter Easy maintenance - fan casing can be separated into different sections allowing easy cleaning. The drain pan can also be cleaned easily on-site as the pipe connector can be quickly removed Optional decoration covers

Technical Information
PCA-RP-HA - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) AIRFLOW (m3/min) PIPE SIZE mm(in) NOISE (dBA) DIMENSIONS (mm) Lo-Hi Gas Liquid Lo-Hi Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) - HRC (A) INTERCONNECTING CABLE No. CORES PCA-RP125HA 14.3 12.3 12.2 11.05 0.77 30-38 15.88 (5/8) 9.52 (3/8) 44-50 1520 650 280 56 Fed by Outdoor Unit Single 6 4

PUH-P - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (KW) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) [MAX] FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 30m Heating/Cooling Heating/Cooling (nominal) Heating/Cooling (UK) Heating/cooling PUH-P125YHA 52 / 50 131 950 330 + 30 1350 380-415v, 50Hz 3 5.01 / 4.55 4.46 / 3.87 70 7.76 / 7.98 [16.3] 20 5 50 50 5.0

Page 100

Dimensions

INDOOR UNIT PCA-RP125HA

Front View

>
1608 1564 110 102

1370 1520

75

Lower View

>
Side View

>

650

1520

258

280

650

Page 101

PCA-RP-HA Heat Pump

Mr Slim Range 2008

PSA-RP Power Inverter Heat Pump


Floor Standing System
The PSA-RP Floor Standing System compliments the Mitsubishi Electric range of indoor units. The sleek, modern design of this unit is ideal for numerous applications including bars and restaurants.
s

Built in controller

Note: When used with a Mr Slim Multi-Split system. PSA-RP cannot be connected with indoor units of different type.

Technical Information
PSA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) COP / EER (nominal) ENERGY LABEL AIRFLOW (m3/min) PIPE SIZE mm(in) NOISE (dBA) DIMENSIONS (mm) Heating/Cooling Lo-Hi Gas Liquid Lo-Hi Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) - HRC (A) INTERCONNECTING CABLE No. CORES PSA-RP71GA 7.6 (3.5-10.2) 7.1 (3.3-8.1) 6.45 (3.0-8.65) 6.4 (2.95-7.3) 0.73 3.41 / 3.23 B /A 15-18 15.88 (5/8) 9.52 (3/8) 40-45 600 270 1900 43 Fed by Outdoor Unit Single 6 4 PSA-RP125GA 14.0 (5.0-16.0) 12.4 (5.5-14.0) 11.9 (4.25-13.6) 11.15 (4.95-12.6) 0.75 3.41 / 3.01 B/B 26-33 15.88 (5/8) 9.52 (3/8) 46-51 600 350 1900 51 Fed by Outdoor Unit Single 6 4

PUHZ-RP - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (KW) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) Single Phase Heating/Cooling [MAX] 3 Phase FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 30m Heating/Cooling (nominal) Heating/Cooling (UK) Heating/cooling PUHZ-RP71VHA3 48 / 47 68 950 330 + 30 943 220-240v, 50Hz Single 2.23 / 2.20 1.98 / 1.87 5 10.4 / 8.7 [19] 25 3 50 30 3.5 PUHZ-RP125VHA2/YHA2 52 / 50 116 / 130 950 330 + 30 1350 220-240v, 50Hz / 380-415v, 50Hz Single / 3 4.11 / 4.12 3.66 / 3.50 5 17.21 / 16.76 [28] 6.43 / 6.27 [13] 32 / 16 3 / 5 75 30 5.0

Page 102

Dimensions

INDOOR UNIT PSA-RP71GA


Front View

>

Side View

>

Upper View

>

INDOOR UNIT PSA-RP125GA


Front View

>

Side View

>

Upper View

>

Page 103

PSA-RP Power Inverter Heat Pump

Mr Slim Range 2008

PSA-RP Standard Inverter Heat Pump


Floor Standing System
The Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the more expensive Power Inverter range. The PSA-RP Floor Standing System compliments the Mitsubishi Electric range of indoor units. The sleek, modern design of this unit is ideal for numerous applications including bars and restaurants.
s

Built in controller

Note: When used with a Mr Slim Multi-Split system. PSA-RP cannot be connected with indoor units of different type.

Technical Information
PSA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) COP / EER (nominal) ENERGY LABEL AIRFLOW (m3/min) PIPE SIZE mm(in) NOISE (dBA) DIMENSIONS (mm) Heating/Cooling Lo-Hi Gas Liquid Lo-Hi Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) - HRC (A) INTERCONNECTING CABLE No. CORES PSA-RP125GA 14.0 (5.0-16.0) 12.3 (5.5-14.0) 11.9 (4.25-13.6) 11.05 (4.95-12.6) 0.76 2.81 / 2.81 D/C 26-33 15.88 (5/8) 9.52 (3/8) 46-51 600 350 1900 51 Fed by Outdoor Unit Single 6 4

PUHZ-P - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (KW) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) [MAX] FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 30m Heating/Cooling Heating/Cooling (nominal) Heating/Cooling (UK) Heating/cooling PUHZ-P125VHA2 55 / 51 99 950 330 + 30 1350 220-240v, 50Hz Single 4.98 / 4.38 4.43 / 3.72 14 17.97 / 18.6 [28] 32 3 50 30 4.5

Page 104

Dimensions

INDOOR UNIT PSA-RP125GA


Front View

>

Side View

>

Upper View

>

Page 105

PSA-RP Standard Inverter Heat Pump

Mr Slim Range 2008

PSA-RP Heat Pump


Floor Standing System
The Heat Pump system provides a low cost alternative to three phase Power Inverter systems. The PSA-RP Floor Standing System compliments the Mitsubishi Electric range of indoor units. The sleek, modern design of this unit is ideal for numerous applications including bars and restaurants.
s

Built in controller

Note: When used with a Mr Slim Multi-Split system. PSA-RP cannot be connected with indoor units of different type.

Technical Information
PSA-RP - INDOOR UNITS
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF (nominal) AIRFLOW (m3/min) PIPE SIZE mm(in) NOISE (dBA) DIMENSIONS (mm) Lo-Hi Gas Liquid Lo-Hi Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLY PHASE FUSE RATING (BS88) - HRC (A) INTERCONNECTING CABLE No. CORES PSA-RP125GA 14.3 12.3 12.2 11.05 0.75 26-33 15.88 (5/8) 9.52 (3/8) 46-51 600 350 1900 51 Fed by Outdoor Unit Single 6 4

PUH-P - OUTDOOR UNITS


MODEL REFERENCE
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (KW) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) [MAX] FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 30m Heating/Cooling Heating/Cooling (nominal) Heating/Cooling (UK) Heating/cooling PUH-P125YHA 52 / 50 131 950 330 + 30 1350 380-415v, 50Hz 3 4.41 / 4.54 3.92 / 3.86 70 7.8 / 8.02 [16.4] 20 5 50 50 5.0

Page 106

Dimensions

INDOOR UNIT PSA-RP125GA


Front View

>

Side View

>

Upper View

>

Page 107

PSA-RP Heat Pump

Mr Slim Range 2008

PHV DXE Heat Pump Air Curtain


Heat Pump Air Curtain System
In collaboration with Thermoscreens, Mitsubishi Electric have developed a range of air cur tains that are able to be connected to our Power Inver ter heat pumps, as opposed to the more traditional direct electric method associated with air cur tains.
s s s s s s s s s

Reduced CO2 emissions (up to 67%) Reduced Running Costs (up to 67%) 2.5 year payback period against equivalent Electric system Inverter technology (does not waste energy) Range of different sizes to suit every application Allows open door policy in retail outlets whilst being energy efficient Clean environment - protection from dust, fumes etc Comfortable climate for customers Easy to install and maintain

Technical Information
PHV DXE - RECESSED
MODEL REFERENCE
DIMENSIONS (mm) (WxDxH) SUPPLY (50Hz) HEAT OUTPUT (kW) COP LOADING (amps) VELOCITY (m/s) AIR VOLUME (m3/h) WEIGHT (kg) dB(A) @ 3m 100% / 50% MAX. MOUNTING HEIGHT (m) OUTDOOR UNIT MODEL 100% / 50% 100% / 50% PHV1500R DXE HO 1650x436x296 415V*1 14.4 / 8.3 2.5 / 3.7 12.7*1 9 2600 67 60 / 58 3.5 PUHZ-RP140VHA2/YHA2 PHV2000R DXE LO 2240x436x296 415V*2 14.1 / 7.9 2.9 / 3.7 15.7*2 9.5 3300 85 61 / 59 3.5 PUHZ-RP100VHA3/YHA3 PHV2000R DXE HO 2240x436x296 415V*2 21.3 / 11.2 2.4 / 3.2 15.7*2 9 3130 88 61 / 59 3.5 PUHZ-RP200YHA2

Notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load

*2 for units with electric heaters disabled, 240v power supply 2.7 amp load.

PHV DXE - FREE STANDING


MODEL REFERENCE
DIMENSIONS (mm) (WxDxH) SUPPLY (50Hz) HEAT OUTPUT (kW) COP LOADING (amps) VELOCITY (m/s) AIR VOLUME (m3/h) WEIGHT (kg) dB(A) @ 3m 100% / 50% MAX. MOUNTING HEIGHT (m) OUTDOOR UNIT MODEL 100% / 50% 100% / 50% PHV1500 DXE HO 1746x377x255 415V*1 14.4 / 8.3 2.5 / 3.7 12.7*1 9 2600 60 60 / 58 3.75 PUHZ-RP140VHA2/YHA2 PHV2000 DXE LO 2296x377x255 415V*2 14.1 / 7.9 2.9 / 3.7 15.7*2 9.5 3300 78 61 / 59 3.75 PUHZ-RP100VHA3/YHA3 PHV2000 DXE HO 2296x377x255 415V*2 21.3 / 11.2 2.4 / 3.2 15.7*2 9.5 3130 80 61 / 59 3.75 PUHZ-RP200YHA2

Notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load

*2 for units with electric heaters disabled, 240v power supply 2.7 amp load.

HEAT PUMP OUTDOOR UNITS


MODEL REFERENCE
DIMENSIONS (mm) (WxDxH) SUPPLY (50Hz) MAX. CURRENT (A) FUSE SIZE HRC (BS88) MAX. PIPE RUN PIPE SIZES Length (m) Height (m) Gas mm(in) Liquid mm(in) INTERCONNECTING CABLE PUHZ-RP100VHA3/YHA3 950x330+30x1350 230V / 415V 28 / 13 32 / 16 50 30 15.88 (5/8) 9.52 (3/8) 2 core PUHZ-RP140VHA2/YHA2 950x330+30x1350 230V / 415V 29.5 / 13 40 / 16 50 30 15.88 (5/8) 9.52 (3/8) 2 core PUHZ-RP200YHA2 950x330+30x1350 415V 19 25 100 30 28.58 (1 1/8) 9.52 (3/8) 2 core

Page 108

Dimensions

AIR CURTAIN PHV1500/2000R DXE


Side View

>

Rear View

>

Upper View

>

AIR CURTAIN PHV1500/2000 DXE


Side View

>

Rear View

>

Upper View

>
PHV DXE Air Curtain
Page 109

Mr Slim Range 2008

Mr Slim Multi-Split Systems


Heat Pump
The multi-split system is an ideal option for open plan spaces in medium sized premises such as offices or shops, where two, three or four units are required. These can be Mr Slim ceiling cassettes (PLA-RP), ceiling suspended (PCA-RP), ducted (PEAD-RP), floor standing (PSA-RP) or wall mounted (PKA-RP) models and can be connected to a single outdoor unit using twin, triple or quadruple multi distributor pipes.
s

Twin, triple or quadruple indoor heat pump units can be operated in Multi-Split configuration from a single outdoor unit Heat pumps must operate in same heating or cooling mode Cooling capacity range 3.3 to 28kW Heating capacity range 3.5 to 31.5kW

s s s

Note: SEZ or SLZ units cannot be used as part of a Mr Slim Multi-Split system. PSA-RP cannot be connected with indoor units of different type.

Technical Information

PIPE RUN PARAMETERS Outdoor Model


PUH-P100-140YHA PUH-P100-140YHA PUH-P100-140YHA PUHZ-P100-140VHA2 PUHZ-P200/250YHA PUHZ-RP71VHA3 PUHZ-RP100-140V/YHA2/3 PUHZ-RP200/250YHA2 PUHZ-P140VHA2 PUHZ-P200/250YHA PUHZ-RP140V/YHA2 PUHZ-RP200/250YHA2 PUHZ-P200/250YHA PUHZ-RP200/250YHA2 PUHZ-P100-140VHA2 PUHZ-RP71-140V/YHA2/3 PUHZ-P200/250YHA PUHZ-RP200/250YHA2
H = 30m. h = 1m.

Pipe Runs
A+B+C twin A+B+C+D triple B C or C D or B D A+B+C twin A+B+C twin A+B+C twin A+B+C twin A+B+C twin A+B+C+D triple A+B+C+D triple A+B+C+D triple A+B+C+D triple A+B+C+D+E quadruple A+B+C+D+E quadruple B C or C D or B D B C or C D or B D B - C or B - D or B - E or C - D or C - E or D - E B - C or B - D or B - E or C - D or C - E or D - E

Max. Pipe Run (m)


50 50

8
50 70 50 75 80 (120) 50 70 75 80 (120) 70 80 (120)

8 8 8 8

Note: H for the PUHZ-RP200/250YHA2 = 40m

TWIN
Indoor Units h C B

TRIPLE
Indoor Units h B C h D

QUADRUPLE
Indoor Units B h C

Multi distributor Pipes Outdoor Units A Multi distributor H Pipes H A

D Outdoor Units Multi distributor Pipes A H E Outdoor Units

Page 110

Technical Information

Multi-Split Systems - Combinations Table


Indoor Unit Outdoor Heat Pump PUHZ-RP71 PUH-P100 PUHZ-P100 PUHZ-RP100 PUH-P125 PUHZ-P125 PUHZ-RP125 PUH-P140 PUHZ-P140 PUHZ-RP140 PUH-P140 PUHZ-P140 PUHZ-RP140 PUHZ-P200 PUHZ-P200 PUHZ-P200 PUHZ-RP200 PUHZ-RP200 PUHZ-RP200 PUHZ-P250 PUHZ-P250 PUHZ-P250 PUHZ-RP250 PUHZ-RP250 PUHZ-RP250 No. of Indoor Units 2 2 2 2 2 2 2 2 2 2 3 3 3 2 3 4 2 3 4 2 3 4 2 3 4 Total Heating Capacity (kW) 3.5 - 10.2 11.5 4.5 - 12.5 4.5 - 14.0 14.3 5.0 - 16.0 5.0 - 16.0 17.0 5.0 - 18.0 5.0 - 18.0 17.0 5.0 - 18.0 5.0 - 18.0 9.5 - 25.0 9.5 - 25.0 9.5 - 25.0 9.5 - 25.0 9.5 - 25.0 9.5 - 25.0 12.5 - 31.5 12.5 - 31.5 12.5 - 31.5 12.5 - 31.5 12.5 - 31.5 12.5 - 31.5 Total Cooling Capacity (kW) 3.3 - 8.1 10.0 4.9 - 11.2 4.9 - 11.4 12.3 5.5 - 14.0 5.5 - 14.0 14.2 5.5 - 15.0 5.5 - 15.3 14.2 5.5 - 15.0 5.5 - 15.3 9.0 - 22.4 9.0 - 22.4 9.0 - 22.4 9.0 - 22.4 9.0 - 22.4 9.0 - 22.4 11.2 - 28.0 11.2 - 28.0 11.2 - 28.0 11.2 - 28.0 11.2 - 28.0 11.2 - 28.0 Pipe Kit Part Number MSDD-50SR-E MSDD-50SR-E MSDD-50SR-E MSDD-50SR-E MSDD-50SR-E MSDD-50SR-E MSDD-50SR-E MSDD-50SR-E MSDD-50SR-E MSDD-50SR-E MSDT-111R-E MSDT-111R-E MSDT-111R-E MSDD-50WR-E MSDT-111R-E MSDF-1111R-E MSDD-50WR-E MSDT-111R-E MSDF-1111R-E MSDD-50WR-E MSDT-111R-E MSDF-1111R-E MSDD-50WR-E MSDT-111R-E MSDF-1111R-E

Size 35 Size 50 Size 50 Size 50 Size 60 Size 60 Size 60 Size 71 Size 71 Size 71 Size 50 Size 50 Size 50 Size 100 Size 60 Size 50 Size 100 Size 60 Size 50 Size 125 Size 71 Size 60 Size 125 Size 71 Size 60

Page 111

Multi-Split Systems

Mr Slim Range 2008

Outdoor Units
SUZ-KA25/35VA
Upper View

>

Side View Front View

>

>

SUZ-KA50/60/71VA

Upper View

>

Front View

>

Side View

>

Dimensions
Page 112

Dimensions

PUHZ-RP35/50VHA3

Upper View

>

Front View

>

Right Side View

>

PUHZ-RP60/71VHA3 / PUHZ-P100VHA2 / PUH-P100YHA

Upper View

>

Page 113

Outdoor Unit Dimensions

Rear View

>

Left Side View

>

Front View

>

Right Side View

>

Mr Slim Range 2008

Outdoor Units
PUHZ-RP100VHA3/YHA3 / PUHZ-RP125-250VHA2 / PUHZ-P125/140VHA2 PUHZ-P200/250YHA / PUH-P125/140YHA

Upper View

>

Rear View

>

Left Side View

>

Front View

>

Right Side View

>

Dimensions
Page 114

PAC-IF011B-E
Air Handling Unit Controller
The Air Handling Unit Controllers are an interface to allow connection to third party manufacturer equipment. Mitsubishi Electric Mr Slim outdoor units can be used with this interface box, creating an ideal solution when a unique air handling unit is required.
s s s

No need for expansion device Error, operation and defrost output Demand control by analogue or digital inputs (0-10, 4-20mA, 1-5V, 0-10V, Step, Auto-Step)

Technical Information
PAC-IF011B-E
MITSUBISHI ELECTRIC OUTDOOOR UNIT CAPACITY (kW) AUTO STEP Heating (nominal) Cooling (nominal) PUHZ-RP PUHZ-P SUZ-KA PUH-P MANUAL STEP PIPE SIZE (mm) Gas / Liquid HEAT EXCHANGER VOLUME (cm3) DIMENSIONS (mm) PUHZ-RP PUHZ-(R)P SUZ-KA PUH-P Max Capacity Min Capacity Width Depth Height WEIGHT (kg) SIZE 35 4.1 3.5 VHA3 VA VHA3 12.7 / 6.35 9.52 / 6.35 1050 350 336 69 278 2.5 SIZE 50 6.0 5.0 VHA3 VA VHA3 12.7 / 6.35 12.7 / 6.35 1500 500 336 69 278 2.5 SIZE 60 7.0 6.0 VHA3 VA VHA3 15.88 / 9.52 15.88 / 6.35 1800 600 336 69 278 2.5 SIZE 71 7.6 7.1 VHA3 VA VHA3 15.88 / 9.52 15.88 / 9.52 2130 710 336 69 278 2.5 SIZE 100 11.2 10.0 V/YHA3 VHA2 YHA V/YHA3 15.88 / 9.52 15.88 / 9.52 3000 1000 336 69 278 2.5 SIZE 125 14.0 12.5 V/YHA2 VHA2 YHA V/YHA2 15.88 / 9.52 15.88 / 9.52 3750 1250 336 69 278 2.5 SIZE 140 16.0 14.0 V/YHA2 VHA2 YHA V/YHA2 15.88 / 9.52 15.88 / 9.52 4200 1400 336 69 278 2.5 SIZE 200 22.4 19.0 YHA2 YHA YHA2 28.58 / 9.52 6000 2000 336 69 278 2.5 SIZE 250 27.0 22.0 YHA2 YHA YHA2 28.58 / 12.7 7500 2500 336 69 278 2.5

Note: One air handling unit controller is required per air handling unit Cooling: Indoor 27C DB/19C WB, Outdoor 35C DB/24C WB Heating: Indoor 20C DB, Outdoor 7C DB/6C WB

A Control wiring

Thermistor wiring

Piping

Outdoor Unit (Mitsubishi Electric)

Air Handling Unit (field supplied)

Page 115

Outdoor Unit Dimensions / Air Handling Unit Controller

Example:

Air Handling Unit Controller (Mitsubishi Electric)

Controller (field supplied)

Mr Slim Range 2008

Mr Slim Range 2008

Accessories / Optional Extras


M Series
Wall Mounted Units
S70 515 716 S71 000 028 - Terminal block - CN22 connector

Ceiling Concealed Ducted Units

PAC-SK005MT -F PAC-SK004MT -F PAC-SK003MT -F PAC-KE03DM-G MAC-399IF MAC-397IF

130Pa fan motor PEAD-RP71EA 130Pa fan motor PEAD-RP100EA2 130Pa fan motor PEAD-RP125/140EA Optional drain lift pump PEAD-RP35-140EA(2) Interface for connection to M-NET System SEZ-KD25-71VA Interface for group control and run/fault SEZ-KD25-71VA

4-Way Blow Cassette Units

PAC-SH53TM-E PAC-SH59KF-E PLP-6BALM PLP-6BAJ PAC-SA1ME-E PAR-SA9FA-E S70E40714 MAC-399IF MAC-397IF

- Multi function casement PLA-RP35-140BA(2) for fresh air 100mm knockout or to hold the high efficiency filter option - High efficiency filter PLA-RP35-140BA(2) - Grille and infra-red controller PLA-RP35-140BA(2) - Grille with filter lowering function PLA-RP35-140BA(2) - I-See Sensor corner panel PLA-RP35-140BA(2) - Infra-red signal receiver PLA-RP35-140BA(2) - Infra-red controller (PAR-SL97A-E) PLA-RP35-140BA(2) - Interface for connection to M-NET System SLZ-KA25-50VA - Interface for group control and run/fault SLZ-KA25-50VA

Ceiling Suspended Units

PAR-SL99B-E PAC-SE85DMA-E PAC-SE86DMA-E PAC-SG38KF-E PAC-SF81KC-E PAC-SF82KC-E

Wireless remote controller and adaptor Optional drain lift pump PCA-RP50-71GA(2) Optional drain lift pump PCA-RP100-140GA Oil mist filter for PCA-RP71/125HA (12 pack) Decoration covers (front cover & suspending bracket) for PCA-RP71HA Decoration covers (front cover & suspending bracket) for PCA-RP125HA

Outdoor Units

PAC-SG61DS-E PAC-SG58SG-E PAC-SG59SG-E

- Drain socket set PUHZ-RP35-250V/YHA2/3 / PUHZ-P100-250VHA2/YHA - Air outlet guide PUHZ-RP35-50VHA3 - Air outlet guide PUHZ-RP60-250V/YHA2/3, 2 sets required for sizes 100-250

System Control Units

PAC-SE55RA-E PAC-SF40RM-E PAC-YT32PTA-E PAC-SE41TS-E PAC-SF80MA PAC-YT51CRA PAR-21MAA PAC-SK81SI-E

Remote on/off adaptor Run/fault indication Program timer Remote sensor A/M-NET adaptor Simplified remote controller Wired controller Sub interface board

Pipe Kits

MSDD-50SR-E MSDD-50WR-E MSDT -111R-E MSDF-1111R-E

Multi distribution pipe twin units - 50:50 - sizes 71/100/125/140 Multi distribution pipe twin units - 50:50 - sizes 200/250 Multi distribution pipe triple units - 33:33:33 - sizes 140/200/250 Multi distribution pipe quadruple units - 25:25:25:25 - sizes 200/250

Accessories / Optional Extras

Power Supply Terminal Kits

PAC-SH52HR-E PAC-SG96HR-E PAC-SG97HR-E

- Power supply terminal kit for PLA-RP when using PUHZ-RP200/250YHA2 - Power supply terminal kit for PKA-RP / PCA-RP / PSA-RP when using PUHZ-RP200/250YHA2 - Power supply terminal kit for PEAD-RP / PCA-RP-HA when using PUHZ-RP200/250YHA2

Page 116

City Multi
Energy Efficient VRF Systems

The City Multi range


Solutions for more demanding applications

Efficient &
The City Multi range is Mitsubishi Electrics answer to large scale VRF (Variable Refrigerant Flow) applications. The efficiency of City Multi is second to none and offers a substantial increase in energy efficiency, with corresponding EER/COP ratings.
The City Multi Y Series range offers a simple and flexible solution where there is a demand for a changeover capability between heating and cooling, helping to ensure a constant, comfortable indoor climate. Mitsubishi Electric also has the ability to provide simultaneous heating and cooling through its R2 and WR2 systems. The difference here being that this is achieved through only two pipes rather than the conventional three. By using Mitsubishi Electrics 2-pipe heat recovery technology, substantial savings can again be made on annual running costs. With a wide range of 76 indoor units, up to 50 (depending on the capacity available) can be connected to a YHM outdoor unit. Broadening the range of potential City Multi applications is Mitsubishi Electrics 3rd generation water cooled R410A WR2 system. This system not only produces heat recovery from the refrigerant circuit but also via its water circuit, offering double heat recovery potential.

Sophisticated technology, combined with a high level of control and energy efficiency:

City Multi is perfectly positioned to meet the demands of todays market.

Page 118

flexible
The Strength of City Multi
The R410A YHM-A series offers some of the highest EER/COP ratings in the market.

The Basics
What is VRF?
VRF stands for Variable Refrigerant Flow. A VRF air conditioning system modulates the flow of refrigerant depending upon the capacity requirements of the building. A VRF system comprises of a condensing unit sited externally and a series of multiple indoor units to provide cooling and/or heating to the occupied space.

Our answer to VRF


Mitsubishi Electric sets the boundaries of VRF technology with the City Multi range, which is available using R410A refrigerant with zero ODP (Ozone Depletion Potential). The range has been specifically designed for today's building requirements and addresses key market issues such as energy efficiency, adaptability and reliability. Mitsubishi Electric manufactures the only 2-pipe heat recovery simultaneous heating and cooling system in the world and equally unique, a water-cooled version. With user friendly control systems utilising Internet technology and integrated cooling and ventilation indoor units, City Multi is the benchmark and market leader in VRF technology.

What is inverter driven technology?


Mitsubishi Electric spends more than 5% of its turnover on research and development, with our engineers always looking at ways in which we can improve and lead in air conditioning efficiency. The use of inverter technology in our City Multi systems is paramount in this process, working by varying the compressor speed to match the cooling or heating load, thereby consuming only the power necessary to match the exact requirement of the room. When City Multi is operating at partial load, the energy efficiency of the system is significantly higher than at full load. In a typical application partial load conditions prevail for more than 90% of operation time. A fixed speed system can only operate at 100% capacity and cannot match the annual efficiencies of an inverter system

What is a Heat Pump system?


Mitsubishi Electrics City Multi Y Series, is a heat pump system, which provides either heating or cooling to a building at any given time.

What is a Heat Recovery system?


Mitsubishi Electrics City Multi R2 and WR2 series have the ability to provide heating and cooling at the same time in areas connected to the same outdoor unit.

Page 120

Why R410A?
R410A is a more efficient refrigerant as it has a higher specific heat capacity when compared to R407c or R22. This higher energy carrying capacity allows for smaller pipe sizes, longer pipe runs and reduces the volume of refrigerant within a system. This is a major factor when complying with EN378, a European standard concerning safety and environmental requirements in the design, manufacture, installation, operation, maintenance and disposal of refrigerating systems.

Why Heat Recovery?


Flexibility and efficiency are key factors when selecting a heat recovery system. For example, while a heat pump system is adequate for a large open plan office, businesses that have a more partitioned structure to an office will require the need to simultaneously heat or cool different sections of the office according to each users individual preferences. The efficiency of this type of system comes from the ability to use the by-products of cooling and heating to transfer energy where it is required, thus acting as a balanced heat exchanger achieving up to 20% cost savings over a conventional heat pump system. The number of connection sites needed for a R2 / WR2 system are also significantly lower than those needed for a three pipe version. This helps to reduce installation costs, further increasing the savings associated with City Multi.

Comparison example of piping connection sites


= 2 sites = 3 sites

How does the R2 / WR2 Heat Recovery System operate on 2 Pipes?


The secret of City Multi heat recovery systems lies in the

BC Controller
The BC Controller houses a liquid/gas separator, allowing the outdoor unit to deliver a mixture (2 phase) of hot gas for heating and liquid for cooling, all through the same pipe. Three pipe systems allocate a pipe to each of these phases. When this mixture arrives at the BC Controller, it is separated and the correct phase delivered to each indoor unit depending on the individual requirement of either heating or cooling.

Page 121

The technology to make City Multi the natural choice


Energy efficiency has always been the driver for City Multi technological development. Technology that always delivers the quality and reliability needed for commercial air conditioning environments. Mitsubishi Electric spend more than 5% of their turnover on research and development, with our engineers always looking at ways in which we can improve and lead in air conditioning efficiency.

City Multi R410A YHM-A technology


Using the ver y latest in IPM (Intelligent Power Module) technology, precise control of energy input is achieved allowing City Multi to fur ther improve COPs for R410A systems. IPM uses 1Hz steps of capacity control, matching building requirements through more accurate control of the occupied space with reduced power input. As in previous versions, IPM technology operates extremely effectively under part load conditions (50-80% of operating capacity), a condition that most systems will be in for their normal working life. Therefore the consideration of efficiency at part load is accounted for as well as when at peak load conditions, offering high system efficiency all year round.

Stable and smooth operation - 100% inverter control


All City Multi compressors are inverter-driven - Capable of precisely matching a building's cooling and heating demands.
The outdoor unit combinations comprise of one module for 8-18hp systems (for R2 up to 16hp), two modules for 20-36hp systems (for R2, 18-32hp) and three modules for 38-50hp systems (Y series only). Each module carries one inverter compressor making simple and highly reliable control possible. Not only does it allow low starting currents, the inverter driven compressor also provides precise indoor comfort and adapts to the air conditioning load, achieving smooth transition across the range of compressor frequencies.

Y Series 8-18hp / R2 8-16hp

Y Series 20-36hp / R2 18-32hp

Y Series 38-50hp

Page 122

Heat Interchange Circuit


To further enhance the class leading efficiency of City Multi, the unique Heat Interchange Circuit provides extra sub cooling. This system allows optimum refrigerant distribution to multiple indoor units, by allowing more effective use of refrigerant flowing through the electronic expansion valves. Because of the added efficiency, volumes of refrigerant in systems are continuing to reduce.

The difference between YHM-A and previous Mitsubishi Electric models


Technology is key when increased efficiency is demanded. The City Multi YHM-A range is designed to deliver this.
A highly efficient R410A scroll compressor design results in less friction losses at the motor. A simplified refrigerant circuit (low pressure loss) including new accumulator design also adds a few more points to the efficiency scale. Enhancements to the heat interchange circuit, inverter driven fan motor and heat exchanger design, again add vital increases to overall system efficiency and COPs.

CITY MULTI REFRIGERANT CIRCUIT

NORMAL REFRIGERANT CIRCUIT

Total Energy Conser vation


The importance of COP
COP stands for Co-efficient of Performance. It is a measure of the useful energy a system can deliver compared to the energy that it consumes. It is calculated by dividing the energy output by the energy input of a system. The higher the figure then the more efficient the system is deemed to be, with commensurate reduced running costs. For Heat Pumps to be included on the Energy Technology Product List under the Enhanced Capital Allowance scheme, they must achieve a heating COP of 3.4 and a cooling EER (energy efficiency ratio) of 3.0. Therefore every input of 1kW of energy must deliver an output of 3.4kW for heating and 3.0kW for cooling, achieving an energy label of B.

Total Energy Conservation


Comparison of COP (energy efficiency) of an 8hp YHM-A system.

Page 123

Ground Source Heat Pumps


A very efficient source of energy for water source heat pump systems is the Earth itself. Ground source heat pumps use the Earth's natural solar collection and heat storage capabilities as an infinite heat source/heat sink.
At between 1.7m and 3m below the ground, the temperature changes from 17C in the summer to 10C in the winter. Deeper down however, the temperature of the ground is a constant 10C all year round. It is these relatively constant, dependable temperatures that can be harnessed using ground source heat pumps. The constant ground temperatures allow the heat pump to operate at optimum efficiency in both heating and cooling, as the high summer or low winter temperatures do not influence performance. Heat is extracted or rejected into the ground using water which is pumped through a network of plastic pipes.

There are two standard ground source methods available, Open Loop and Closed Loop (Bore Hole or Slinky):
s

Open Loop - Large bodies of water can be utilised as a stable source of water at a relatively constant temperature. This can be either surface water or ground water. Surface water would include lakes, reservoirs, rivers and the sea. Closed Loop Slinky - A trench is dug to a depth of between 1.7 to 3m and plastic
spiral pipe is laid into the bottom. The pipe is covered with sand to provide good ground to pipe contact and then the trench is backfilled with the excavated soil.

Closed Loop Bore Hole - A series of holes are drilled down into the ground at a depth of 50 to 130m, depending on geothermal conditions. Two water pipes connected via a 'u bend' are fed directly into these holes and then surrounded by a conductive grout.

Example of a Closed Loop Bore Hole Application:


Indoor units provide heating or cooling Ground Source Heat Pump installed inside the building, typically 1 per floor

Flow and return water loop supplies water to and from the units Bore Hole absorbs or rejects heat from the ground

Page 124

Highly eff icient & extremely flexible


New Acoustic Kits for PUHY and PURY Series units
A range of Acoustic Kits designed for noise reduction. An industry first, the kits offer a 6dBA noise level reduction from standard.
For supply and / or installation please contact

Ambient Acoustics on 01934 712802

Page 125

Features and
High off coil / High sensible cooling
Poor design or application of air conditioning systems can sometimes lead to cold draughts and uneven room temperatures. Low off coil temperatures cause dehumidifying of the air which can create dry eyes and sore throats. Mitsubishi Electric now provides a High Sensible Cooling Function specifically designed to deal with this. By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants. These high SHFs are available throughout the range of indoor units, allowing optimum selection of units tailored to more specific design criteria.

Reduced noise levels


New fan design
City Multi VRF systems led the introduction of larger single fan rotors some ten years ago, achieving substantially lower noise levels over multiple designs. Continuing the development in the areas of blade shape and weight, Mitsubishi Electric have managed to achieve even higher performance and lower noise levels. To reduce noise levels further and comply with inner city residential noise regulations, all outdoor units include Night Set-back mode. This function works by lowering the fan speed and compressor frequency proportionally with reduction in demand (44dBA for PUHY-P250YHM-A). The compressor compartment is also now sealed, further reducing noise levels.

New fan design


Reduction of operation noise

New control box design


Improvement of reliability and easy maintenance

New heat exchanger design


Improvement of COP

New inverter compressor


Improvement of COP

Page 126

Benefits
Fine Control of the Inverter Provides Better Efficiency and Performance
Air cooled inverters use the ambient temperature to cool the inverter. For water cooled VRF (which are installed inside the building) refrigerant cooling is used to maintain accurate control of the Inverter.

Refrigerant volume checking function


This function runs the system, measuring various temperatures and pressures throughout the system, comparing these to the values stored in the units memory from the previous service. If a leakage has occurred the system will indicate so, enabling customers to easily comply with the F-Gas regulation.

Replace technology
This unique function allows the re-use of refrigerant piping, controllers, power and control wiring for all previously installed Mitsubishi Electric R22 and R407c Heat Recovery and Cooling only systems and partial replace of Heat Pumps (pressure regulations require one pipe from the outdoor to the first branch to be replaced). This function offers unprecedented savings on installation costs, disruption to business and down time, not to mention the considerable running cost and CO2 emission savings - more than halving the running costs compared to a 10 year old unit.

Cooling operation set temperature of 14C


Environments such as gyms, laboratories etc often require the ability to cool lower than the standard comfort cooling setpoint. By selecting a dip switch on the unit, a cooling operation set temperature of 14C DB is possible on the floor standing and ducted models only. The indoor unit fan will be fixed at high speed during this operation.

Page 127

Effective use of space


The new models have a smaller foot print requirement than previous models. The width and depth have been reduced by 7% and 13% respectively, with the height being reduced by 130mm. (PUHY-P250YHM-A compared to previous YGM-A versions).
mm

YGM-A

YHM-A

8-12hp systems (Y / R2 Series) 1.43m2

14-18hp systems (Y Series) 14-16hp systems (R2 Series) 1.89m2

Approximately 21% reduction in foot print


(PUHY-P250)

The unit can easily be transported, even into inaccessible buildings

The narrow space between buildings makes it difficult to use a crane

The downsized outdoor unit can be transported through an 800mm wide lift door

8-12hp outdoor units

Example of lift

Weight reduction
Weight has been reduced by approximately 33kg
(PUHY-P250YHM-A compared to previous YGM-A versions).
YGM-A
YHM-A

33kg

Page 128

Blue Fin treatment


The anti-corrosion Blue Fin treatment of the heat exchanger is especially effective in urban environments where the traffic pollutions can damage the aluminium fins reducing the capacity and life expectancy of the unit.

All City Multi R410A outdoor units have been treated with Blue Fin

R410A pipe sizing


As R410A has a higher specific heat capacity than R22, the pipework is smaller. This means the pipe itself is cheaper, easier to install and less riser space is required within the building.
10hp model

Constant & comfortable indoor climates


Heating operation range Air cooled units
At low ambient temperatures the guaranteed operating range in heating is minus 20C Operating range in cooling is from an outdoor temperature of -5C.

Water temperature operation range WR2 / WY Water cooled units

Outdoor Temperature (C)

Water Temperature (C)

Page 129

City Multi exceeds current demands for Efficiency


The need for energy efficiency is paramount and is determined by legislation and regulation. Businesses saw their energy bills rise by up to 15% with the introduction of the Climate Change Levy in April 2001. A year later, the newly revised Par t L (Par t J in Scotland) of the building regulations placed new standards on design of buildings and plant deployed for heating, cooling and ventilating. A revised version to conform with the Energy Performance of Buildings Directive was also introduced in 2006; all geared to reducing energy consumption and therefore CO2 emissions. To encourage efficient use of energy, the UK Government introduced the Enhanced Capital Allowance Scheme (ECA). Qualifying products on the Energy Technology Product List include heat pumps for space heating. The City Multi range has been designed to ensure businesses qualify for ECA and benefit from the utmost efficiency, both financially and environmentally.

Mitsubishi Electric has produced a series of comprehensive CPD approved guides. These include:
s s s s s s s s s s s s s s s s s

The Energy Performance of Buildings Directive (EPBD)


Mixed Mode Cooling Systems

Building Energy Management Systems (BEMS) Water Cooled VRF Systems The European F-Gas Regulation The New Part L of the Building Regulations 2006 The New 10% Renewable Energy Target Heat Pump Boilers
Part F of the Building Regulations

The Code for Sustainable Homes Building Energy Ratings Renewable Energy Sources Maintenance, Replacement and the WEEE Directive Combined Heat and Power Carbon Reduction in the Built Environment The Application of Heat Pump Boilers The Enhanced Capital Allowance Scheme (2008)

Page 130

Enhanced Capital Allowance Scheme (ECA)


The key features of the scheme:
s Under the scheme, all businesses liable for UK corporation tax, are able to claim an enhanced capital allowance on any

qualifying expenditure (regardless of size and location of business or whether in the industrial or commercial sector)
s Businesses can offset the full cost of specific technologies (such as City Multi) against taxable profits

of the period of the investment


s In order to qualify for this scheme, technology has to meet the energy saving criteria as published in the Energy Technology

Criteria List. City Multi fully meets this criteria in its drive for energy efficiency
s Only investment in new and unused plant and machinery qualify

For further information go to www.eca.gov.uk and click on Mitsubishi Electric Air Conditioning under the heat pump category.

Page 131

A wide choice of models


The new YHM-A air sourced outdoor models are modular in design and as such differing combinations of them can be connected together to create the required outdoor unit size needed for a particular application.
Both the Y Series and R2 ranges come in standard (-P) and high COP (-EP) versions. In addition, the standard versions allow for space-saving by virtue of the combination of units having a smaller foot print than the high COP versions.

The model line up


Size Series Model Name Y
PUHY-P YHM-A PUHY-EP YHM-A

200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 1250
8hp 10hp 12hp 14hp 16hp 18hp 20hp 22hp 24hp 26hp 28hp 30hp 32hp 34hp 36hp 38hp 40hp 42hp 44hp 46hp 48hp 50hp

I I I I

I I I I

I I

I I I I

I I I

I I I I

I I I I

I I I I

I I I

I I I

I I I

I I I

I I

I I

R2

PURY-P YHM-A PURY-EP YHM-A

Y Series Heat Pump - Standard Version


Y Series (10-12hp) PUHY-P YHM-A Y Series (14 - 18hp) PUHY-P YHM-A Y Series (20 - 26hp) PUHY-P YSHM-A

10hp PUHY-P250YHM-A

12hp PUHY-P300YHM-A

14hp PUHY-P350YHM-A

16hp PUHY-P400YHM-A

18hp PUHY-P450YHM-A

20hp

22hp

24hp

26hp

PUHY-P500YSHM-A PUHY-P550YSHM-A PUHY-P600YSHM-A PUHY-P650YSHM-A

Y Series (28-36hp) PUHY-P YSHM-A

Y Series (38 - 40hp) PUHY-P YSHM-A

Y Series (42hp) PUHY-P YSHM-A

28hp
PUHY-P700YSHM-A

30hp
PUHY-P750YSHM-A

32hp
PUHY-P800YSHM-A

38hp PUHY-P950YSHM-A

40hp PUHY-P1000YSHM-A

42hp PUHY-P1050YSHM-A

34hp
PUHY-P850YSHM-A

36hp
PUHY-P900YSHM-A

Y Series (44-50hp) PUHY-P YSHM-A

44hp

46hp

48hp

50hp

PUHY-P1100YSHM-A PUHY-P1150YSHM-A PUHY-P1200YSHM-A PUHY-P1250YSHM-A

Page 132

Y Series Heat Pump - High COP Version


Y Series - High COP (8 - 12hp) PUHY YHM-A -EP Y Series - High COP (16 - 20hp) PUHY YSHM-A -EP Y Series - High COP (22 - 26hp) PUHY YSHM-A -EP

8hp PUHY-EP200YHM-A

12hp PUHY-EP300YHM-A

16hp

18hp

20hp
PUHY-EP500YSHM-A

22hp
PUHY-EP550YSHM-A

24hp

26hp

PUHY-EP400YSHM-A PUHY-EP450YSHM-A

PUHY-EP600YSHM-A PUHY-EP650YSHM-A

Y Series - High COP (28 - 30hp) PUHY YSHM-A -EP

Y Series - High COP (32 - 34hp) PUHY YSHM-A -EP

Y Series - High COP (36hp) PUHY YSHM-A -EP

28hp PUHY-EP700YSHM-A

30hp PUHY-EP750YSHM-A

32hp PUHY-EP800YSHM-A

34hp PUHY-EP850YSHM-A

36hp PUHY-EP900YSHM-A

R2 Series Heat Recovery - Standard Version


R2 Series (10 - 12hp) PURY-P YHM-A R2 Series (14 - 16hp) PURY YHM-A -P R2 Series (18 - 24hp) PURY YSHM-A -P

10hp PURY-P250YHM-A

12hp PURY-P300YHM-A

14hp PURY-P350YHM-A

16hp PURY-P400YHM-A

20hp PURY-P500YSHM-A

22hp PURY-P550YSHM-A

24hp PURY-P600YSHM-A

R2 Series (26 - 28hp) PURY YSHM-A -P

R2 Series (30 - 32hp) PURY YSHM-A -P

26hp PURY-P650YSHM-A

28hp PURY-P700YSHM-A

30hp PURY-P750YSHM-A

32hp PURY-P800YSHM-A

R2 Series Heat Recovery - High COP Version


R2 Series - High COP (8 -12hp) PURY YHM-A -EP R2 Series - High COP (16 - 18hp) PURY YSHM-A -EP R2 Series - High COP (20 - 22hp) PURY YSHM-A -EP

8hp PURY-EP200YHM-A

12hp PURY-EP300YHM-A

16hp PURY-EP400YSHM-A

18hp PURY-EP450YSHM-A

20hp PURY-EP500YSHM-A

22hp PURY-EP550YSHM-A

R2 Series - High COP (24hp) PURY YSHM-A -EP

24hp PURY-EP600YSHM-A

Page 133

City Multi Product Range Overview


Outdoor Units
14kW Cooling Capacity
Y Series (4/5/6hp) WY / WR2 WY / WR2

PUMY-P100-140V/YHMA

PQ(H/R)Y-P200/250YGM-A

PQ(H/R)Y-P400/500YSGM-A

Indoor Units
Model / Size 15 (1.7kW) 20 (2.2kW) 25 (2.8kW) 32 (3.6kW) 40 (4.5kW)

PLFY-P-VBM-E PLFY-P-VCM-E PLFY-P-VLMD-E PMFY-P-VBM-E PEFY-P-VMS1-E PEFY-P-VMM-E PEFY-P-VMH-E PCFY-P-VGM-E PKFY-P-VBM/VGM/VFM-E PFFY-P-VLRM-E PFFY-P-VLRMM-E PFFY-P-VLEM-E PFFY-P-VKM-E GUF-RD3 PQFY-P

Page 134

140kW Cooling Capacity


Y / R2 Series Standard Y / R2 Series High COP Y / R2 Series Standard Y / R2 Series High COP

PUH/RY-P250/300YHM-A

PUH/RY-EP200YHM-A

PUH/RY-P350-450YHM-A*1

PUH/RY-EP300YHM-A

50 (5.6kW)

63 (7.1kW)

80 (9.0kW)

100 (11.2kW)

125 (14.0kW)

140 (16.0kW)

250 (28.0kW)

*1 Size 450 only available for Y Series

Page 135

The energy efficient

City Multi VRF range


Unique 2-pipe technology provides simultaneous heating and cooling, alongside excellent energy efficiency and corresponding EER/COP ratings. Up to 50 indoor units can be connected to a single outdoor unit, offering the sophistication, control and energy efficiency demanded today.

Simple technology
at its best
Systems marked with the ECA logo are registered on the Energy Technology List and hence qualify for 100% first year enhanced capital allowances (whole system cost and reasonable cost of installation). For further information please go to www.eca.gov.uk

Nominal conditions cooling: indoor 27C DB, 19C WB; outdoor 35C DB, 24C WB. Nominal conditions heating: indoor 20C DB; outdoor 7C DB, 6C WB. UK Conditions: Summer; indoor 21C DB, 15C WB; outdoor 27C DB. Winter; indoor 21C DB; outdoor -1C WB.

Page 136

Contents
138 140 142 144 146 148 150 152 154 156 158 160 162 164 166 168 170 172 174 176 178 180 182 184 186 188 190 192 194 196 197

Y Series (4-6hp) Heat Pump, Outdoor Unit Y Series Standard (10-18hp) Heat Pump, Outdoor Unit Y Series Standard (20-36hp) Heat Pump, Outdoor Unit Y Series Standard (38-50hp) Heat Pump, Outdoor Unit Y Series High COP (8-26hp) Heat Pump, Outdoor Unit Y Series High COP (28-36hp) Heat Pump, Outdoor Unit WY Series (8-20hp) Water Cooled Heat Pump, Outdoor Unit R2 Series Standard (10-16hp) Heat Recovery, Outdoor Unit R2 Series Standard (20-32hp) Heat Recovery, Outdoor Unit R2 Series High COP (8-24hp) Heat Recovery, Outdoor Unit R2 Series Piping Restrictions WR2 Series (8-20hp) Water Cooled Heat Recovery, Outdoor Unit PFD-P-VM-E Heat Pump, Close Control System PLFY-P-VBM-E 2, 3 and 4-Way Blow Ceiling Cassette Indoor Unit PLFY-P-VCM-E 600x600 4-Way Blow Ceiling Cassette Indoor Unit PLFY-P-VLMD-E 2-Way Blow Ceiling Cassette Indoor Unit PMFY-P-VBM-E 1-Way Blow Ceiling Cassette Indoor Unit PEFY-P-VMS1-E Ultra Thin Ceiling Concealed Ducted Indoor Unit PEFY-P-VMM-E Ceiling Concealed Ducted Indoor Unit PEFY-P-VMH-E High Static Pressure Ceiling Concealed Ducted Indoor Unit PCFY-P-VGM-E Ceiling Suspended Indoor Unit PKFY-P-VBM/VGM/VFM-E Wall Mounted Indoor Unit PFFY-P-VLRM-E Floor Standing Concealed Indoor Unit PFFY-P-VLRMM-E Floor Standing Concealed Indoor Unit PFFY-P-VLEM-E Floor Standing Exposed Indoor Unit PFFY-P-VKM-E Floor Standing Exposed Indoor Unit GUF-RD3 Lossnay Outdoor Air Processing Unit PQFY-P VRF Heat Pump Boiler BC Controllers Air Handling Unit Controllers Accessories / Optional Extras

Page 137

Y Series (4-6hp)
Heat Pump Outdoor Unit
The latest in Mitsubishi Electric R410A Y Series technology. The new City Multi models allow up to 8 indoor units to be connected to a single outdoor unit, using the standard branch/header pipework system proven in the larger models. Utilising the latest Mitsubishi Electric inver ter technology, the system is fully controllable with all City Multi controllers or linked to third party BEMS.
s

A two core non-polar transmission line allows for simple installation of up to eight indoor units Latest in inverter technology including a highly efficient DC Scroll Compressor, DC fan motor and Demand Control The condensing unit is extremely slimline which allows easy location and application of the system Single or three phase power supply Anti-Corrosion blue and flat fin technology Size 15 PEFY-P-VMS1-E now able to connect to PUMY

s s s

Technical Information
Y SERIES OUTDOOR UNIT - 4-6hp
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) PUMY-P100VHMA PUMY-P100YHMA PUMY-P125VHMA PUMY-P125YHMA PUMY-P140VHMA PUMY-P140YHMA 12.5 11.2 10.4 10.3 3.66 3.34 3.27 2.84 3.42 / 3.35 6 14.5 (130%) 100 15.88 (5/8) 9.52 (3/8) 51 / 49 127 950 330+30 1350 220-240v, 50Hz Single 5 15.5 14.1 -5C ~ 46C -15C ~ 15C 40 3 12.5 11.2 10.4 10.3 3.63 3.3 3.23 2.81 3.44 / 3.39 6 14.5 (130%) 100 15.88 (5/8) 9.52 (3/8) 51 / 49 140 950 330+30 1350 380-415v, 50Hz 3 5 5.32 4.84 -5C ~ 46C -15C ~ 15C 16 4 + earth 16.0 14.0 13.3 12.9 4.33 4.32 3.85 3.66 3.69 / 3.24 8 18.2 (130%) 100 15.88 (5/8) 9.52 (3/8) 52 / 50 127 950 330+30 1350 220-240v, 50Hz Single 5 18.3 18.3 -5C ~ 46C -15C ~ 15C 40 3 16.0 14.0 13.3 12.9 4.29 4.27 3.82 3.63 3.73 / 3.28 8 18.2 (130%) 100 15.88 (5/8) 9.52 (3/8) 52 / 50 140 950 330+30 1350 380-415v, 50Hz 3 5 6.29 6.26 -5C ~ 46C -15C ~ 15C 16 4 + earth 18.0 15.5 14.9 14.3 5.58 5.35 4.99 4.53 3.23 / 2.90 8 20.2 (130%) 100 15.88 (5/8) 9.52 (3/8) 53 / 51 127 950 330+30 1350 220-240v, 50Hz Single 5 23.6 22.7 -5C ~ 46C -15C ~ 15C 50 3 18.0 15.5 14.9 14.3 5.32 5.32 4.73 4.52 3.38 / 2.91 8 20.2 (130%) 100 15.88 (5/8) 9.52 (3/8) 53 / 51 140 950 330+30 1350 380-415v, 50Hz 3 5 7.8 7.8 -5C ~ 46C -15C ~ 15C 16 4 + earth

POWER INPUT (kW)

COP / EER (nominal) Max no. OF CONNECTABLE INDOOR UNITS Max CONNECTABLE CAPACITY AIRFLOW (m3/min) PIPE SIZE mm(in) Gas Liquid NOISE (dBA) Heating/Cooling WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) RUNNING CURRENT (A) Heating Cooling GUARANTEED OPERATING RANGE Cooling Heating FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores

Optional Parts
PUMY-P100-140VHMA/YHMA Piping Restrictions
TOTAL PIPING LENGTH FURTHEST PIPING LENGTH FURTHEST PIPING LENGTH AFTER 1st BRANCH BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT BETWEEN INDOOR AND INDOOR UNITS - HEIGHT 120m max 80m max 30m max 30m max (20m max if outdoor installed below) 12m max

Model Name
CMY-Y62-G-E

Description
Branch Pipe (2 Branch)

Page 138

Dimensions

PUMY-P100-140VHMA/YHMA

Upper View

>

Side View

>

Front View

>

Page 139

Y Series (4-6hp)

City Multi Range 2008

Y Series Standard (10-18hp)


Heat Pump Outdoor Unit
Improved for even higher efficiency
The City Multi Y series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.
s s s s s s s s

New wrap around coil for improved energy efficiency Choice of Branch Pipe or Header Pipe feeds to indoor units Energy-saving inverter driven outdoor compressor units with very low start currents No requirement for plant rooms or bulky service shafts Weight and size reduction compared to previous YGM-A models Improved pipe run of 165m, with a total system pipe length of 1000m 100% inverter control High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

Technical Information
Y SERIES STANDARD OUTDOOR UNITS 10-18hp
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) POWER INPUT (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) COP/EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min) NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth (1650mm without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) RUNNING CURRENT (A) Heating Cooling FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores Height High PUHY-P250YHM-A 31.5 28.0 28.7 26.6 7.83 7.73 7.75 4.79 4.02 / 3.62 21 185 57 200 920 760 1710 380-415v, 50Hz 3 8 12.1 11.9 32 4 + earth PUHY-P300YHM-A 37.5 33.5 33.0 31.5 9.39 9.07 9.11 6.71 3.99 / 3.69 26 185 59 215 920 760 1710 380-415v, 50Hz 3 8 14.5 14.0 32 4 + earth PUHY-P350YHM-A 45.0 40.0 39.6 37.6 12.09 11.20 11.73 8.29 3.72 / 3.57 30 225 60 245 1220 760 1710 380-415v, 50Hz 3 8 18.6 17.3 32 4 + earth PUHY-P400YHM-A 50.0 45.0 44.0 42.3 13.47 13.23 13.07 9.79 3.71 / 3.40 34 225 61 245 1220 760 1710 380-415v, 50Hz 3 8 20.8 20.4 40 4 + earth PUHY-P450YHM-A 56.0 50.0 48.7 46.0 15.38 16.28 14.00 11.40 3.64 / 3.07 39 225 62 245 1220 760 1710 380-415v, 50Hz 3 8 23.7 25.1 50 4 + earth

PUHY-P250-450YHM-A Piping Restrictions


TOTAL PIPING LENGTH FURTHEST PIPING LENGTH FURTHEST PIPING LENGTH AFTER 1st BRANCH BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT BETWEEN INDOOR AND INDOOR UNITS - HEIGHT 1000m max 165m max 40m max 50m max (40m max if outdoor installed below) 15m max

Page 140

Dimensions

PUHY-P250, 300YHM-A

Upper View

>

Side View

>
Front View

>

PUHY-P350, 400, 450YHM-A

Upper View

>

Side View

>

Front View

>
Y Series Standard (10-18hp)
Page 141

City Multi Range 2008

Y Series Standard (20-36hp)


Heat Pump Outdoor Unit
Improved for even higher efficiency
The City Multi Y series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.
s s s s s s s s

New wrap around coil for improved energy efficiency Choice of Branch Pipe or Header Pipe feeds to indoor units Energy-saving inverter driven outdoor compressor units with very low start currents No requirement for plant rooms or bulky service shafts Weight and size reduction compared to previous YGM-A models Improved pipe run of 165m, with a total system pipe length of 1000m 100% inverter control High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

Technical Information
Y SERIES STANDARD OUTDOOR UNITS 20-36hp
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) POWER INPUT (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) COP/EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min) NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth (1650mm without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) RUNNING CURRENT (A) Heating Cooling FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores Height High
PUHY-P500YSHM-A PUHY-P550YSHM-A PUHY-P600YSHM-A PUHY-P650YSHM-A PUHY-P700YSHM-A PUHY-P750YSHM-A PUHY-P800YSHM-A PUHY-P850YSHM-A PUHY-P900YSHM-A 63.0 56.0 54.8 51.5 16.40 16.47 14.92 11.53 3.84 / 3.40 43 185 / 185 60 200 + 200 920 + 920 760 1710 380-415v, 50Hz 3 8/8 25.3 25.4 32 / 32 4 + earth 69.0 63.0 60.0 58.0 18.06 18.36 16.43 12.85 3.82 / 3.43 47 185 / 185 60.5 215 + 200 920 + 920 760 1710 380-415v, 50Hz 3 8/8 27.9 28.3 32 / 32 4 + earth 76.5 69.0 66.6 63.5 19.92 18.75 18.13 13.13 3.84 / 3.68 50 225 / 185 60.5 245 + 200 1220 + 920 760 1710 380-415v, 50Hz 3 8/8 30.7 28.9 32 / 32 4 + earth 81.5 73.0 70.9 67.2 21.90 20.79 19.93 14.55 3.72 / 3.51 50 225 / 185 61 245 + 215 1220 + 920 760 1710 380-415v, 50Hz 3 8/8 33.8 32.1 32 / 32 4 + earth 88.0 80.0 75.7 73.6 23.71 22.47 22.05 16.18 3.71 / 3.56 50 225 / 225 61 245 + 245 1220 + 1220 760 1710 380-415v, 50Hz 3 8/8 36.6 34.7 32 / 32 4 + earth 95.0 85.0 81.7 78.2 25.46 25.07 23.68 18.05 3.73 / 3.39 50 225 / 225 63 245 + 245 1220 + 1220 760 1710 380-415v, 50Hz 3 8/8 39.3 38.7 40 / 32 4 + earth 100.0 90.0 86.0 82.8 25.70 27.69 23.90 19.94 3.89 / 3.25 50 225 / 225 64 245 + 245 1220 + 1220 760 1710 380-415v, 50Hz 3 8/8 39.7 42.8 50 / 32 4 + earth 108.0 96.0 95.0 88.3 28.42 30.18 26.15 19.92 3.80 / 3.18 50 225 / 225 64.5 245 + 245 1220 + 1220 760 1710 380-415v, 50Hz 3 8/8 43.9 46.6 50 / 40 4 + earth 113.0 101.0 99.4 92.9 30.29 33.33 27.87 22.00 3.73 / 3.03 50 225 / 225 64.5 245 + 245 1220 + 1220 760 1710 380-415v, 50Hz 3 8/8 46.8 51.5 50 / 50 4 + earth

PUHY-P500-900YSHM-A Piping Restrictions


TOTAL PIPING LENGTH FURTHEST PIPING LENGTH FURTHEST PIPING LENGTH AFTER 1st BRANCH BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT BETWEEN INDOOR AND INDOOR UNITS - HEIGHT 1000m max 165m max 40m max 50m max (40m max if outdoor installed below) 15m max

Page 142

Dimensions

PUHY-P500, 550YSHM-A
Side View

>

Front View

>

PUHY-P600, 650YSHM-A
Side View

>

Front View

>

PUHY-P700, 750, 800, 850, 900YSHM-A

Page 143

Y Series Standard (20-36hp)

Side View

>

Front View

>

City Multi Range 2008

Y Series Standard (38-50hp)


Heat Pump Outdoor Unit
Improved for even higher efficiency
The City Multi Y series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.
s s s s s s s s

New wrap around coil for improved energy efficiency Choice of Branch Pipe or Header Pipe feeds to indoor units Energy-saving inverter driven outdoor compressor units with very low start currents No requirement for plant rooms or bulky service shafts Weight and size reduction compared to previous YGM-A models Improved pipe run of 165m, with a total system pipe length of 1000m 100% inverter control High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

Technical Information
Y SERIES STANDARD OUTDOOR UNITS 38-50hp
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) POWER INPUT (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) COP/EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min) NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth (1650mm without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) RUNNING CURRENT (A) Heating Cooling FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores Height High PUHY -P950YSHM-A PUHY -P1000YSHM-A PUHY -P1050YSHM-A PUHY -P1100YSHM-A PUHY -P1150YSHM-A PUHY -P1200YSHM-A PUHY -P1250YSHM-A 119.5 108.0 105.2 99.4 30.02 30.68 27.62 20.25 3.98 / 3.52 50 185 / 185 / 185 64 245 + 215 + 200 1220 + 920 + 920 760 1710 380-415v, 50Hz 3 8/8/8 46.4 47.4 40 / 32 / 32 4 + earth 127.0 113.0 111.8 104.0 33.15 32.47 30.50 21.43 3.83 / 3.48 50 225 / 185 / 185 64 245 + 215 + 215 1220 + 920 + 920 760 1710 380-415v, 50Hz 3 8/8/8 51.2 50.1 40 / 32 / 32 4 + earth 132.0 118.0 116.2 108.6 35.01 33.90 32.21 22.37 3.77 / 3.48 50 225 / 225 / 185 64 245 + 245 + 200 140.0 124.0 123.2 114.1 36.93 35.83 33.98 23.65 3.79 / 3.46 50 225 / 225 / 225 64 245 + 245 + 245 145.0 130.0 127.6 119.6 39.08 39.39 35.95 26.00 3.71 / 3.30 50 225 / 225 / 225 64.5 245 + 245 + 245 1220 + 1220 + 1220 760 1710 380-415v, 50Hz 3 8/8/8 60.4 60.8 50 / 32 / 32 4 + earth 150.0 136.0 132.0 125.1 40.10 41.71 36.89 27.53 3.74 / 3.26 50 225 / 225 / 225 65 245 + 245 + 245 1220 + 1220 + 1220 760 1710 380-415v, 50Hz 3 8/8/8 61.9 64.4 50 / 40 / 32 4 + earth 156.5 140.0 137.7 128.8 42.06 45.01 38.70 29.71 3.72 / 3.11 50 225 / 225 / 225 65.5 245 + 245 + 245 1220 + 1220 + 1220 760 1710 380-415v, 50Hz 3 8/8/8 65.0 69.5 50 / 50 / 32 4 + earth

1220 + 1220 + 920 1220 + 1220 + 1220 760 1710 380-415v, 50Hz 3 8/8/8 54.1 52.4 40 / 32 / 32 4 + earth 760 1710 380-415v, 50Hz 3 8/8/8 57.0 55.3 40 / 32 / 32 4 + earth

PUHY-P950-1250YSHM-A Piping Restrictions


TOTAL PIPING LENGTH FURTHEST PIPING LENGTH FURTHEST PIPING LENGTH AFTER 1st BRANCH BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT BETWEEN INDOOR AND INDOOR UNITS - HEIGHT 1000m max 165m max 40m max 50m max (40m max if outdoor installed below) 15m max

Page 144

Dimensions

PUHY-P950, 1000YSHM-A
Side View

>

Front View

>

PUHY-P1050YSHM-A
Side View

>

Front View

>

PUHY-P1100, 1150, 1200, 1250YSHM-A

Page 145

Y Series Standard (38-50hp)

Side View

>

Front View

>

City Multi Range 2008

Y Series High COP (8-26hp)


Heat Pump Outdoor Unit
Improved for even higher efficiency
The City Multi Y series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.
s s s s s s s s

Highest ever COPs / EERs due to new higher efficiency inverter technology and wrap around coil Choice of Branch Pipe or Header Pipe feeds to indoor units Energy-saving inverter driven outdoor compressor units with very low start currents No requirement for plant rooms or bulky service shafts Weight and size reduction compared to previous YGM-A models Improved pipe run of 165m, with a total system pipe length of 1000m 100% inverter control High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

Technical Information
Y SERIES HIGH COP OUTDOOR UNIT 8-26hp
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) POWER INPUT (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) COP/EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min) NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth (1650mm without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) RUNNING CURRENT (A) Heating Cooling FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores Height High
PUHY -EP200YHM-A PUHY -EP300YHM-A PUHY -EP400YSHM-A PUHY -EP450YSHM-A PUHY -EP500YSHM-A PUHY -EP550YSHM-A PUHY -EP600YSHM-A PUHY -EP650YSHM-A

25.0 22.4 23.0 21.3 5.77 5.18 5.71 3.21 4.33 / 4.32 17 185 57 200 920 760 1710 380-415v, 50Hz 3 8 8.9 8.0 20 4 + earth

37.5 33.5 33.0 31.5 9.28 8.25 9.00 6.11 4.04 / 4.06 26 225 60 245 1220 760 1710 380-415v, 50Hz 3 8 14.3 12.7 32 4 + earth

50.0 45.0 44.0 42.3 11.54 10.41 11.19 7.70 4.33 / 4.32 34 185 / 185 60 200 + 200 920 + 920 760 1710 380-415v, 50Hz 3 8/8 17.8 16.0 20 / 20 4 + earth

56.0 50.0 48.7 46.0 13.05 13.15 11.88 9.21 4.29 / 3.80 39 185 / 185 60 200 + 200 920 + 920 760 1710 380-415v, 50Hz 3 8/8 20.1 20.3 32 / 20 4 + earth

63.0 56.0 54.8 51.5 15.14 13.46 13.78 9.42 4.16 / 4.16 43 225 / 185 62 245 + 200 1220 + 920 760 1710 380-415v, 50Hz 3 8/8 23.4 20.8 32 / 20 4 + earth

69.0 63.0 60.0 58.0 17.12 16.32 15.58 11.42 4.03 / 3.86 47 225 / 185 62 245 + 200 1220 + 920 760 1710 380-415v, 50Hz 3 8/8 26.4 25.2 32 / 32 4 + earth

76.5 69.0 66.6 63.5 18.93 16.99 17.23 11.89 4.04 / 4.06 50 225 / 225 63 245 + 245 1220 + 1220 760 1710 380-415v, 50Hz 3 8/8 29.2 26.2 32 / 32 4 + earth

81.5 73.0 70.9 67.2 19.13 18.34 17.41 12.84 4.26 / 3.98 50 225 / 225 63 245 + 245 1220 + 1220 760 1710 380-415v, 50Hz 3 8/8 29.5 28.3 32 / 32 4 + earth

PUHY-EP200-650Y(S)HM-A Piping Restrictions


TOTAL PIPING LENGTH FURTHEST PIPING LENGTH FURTHEST PIPING LENGTH AFTER 1st BRANCH BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT BETWEEN INDOOR AND INDOOR UNITS - HEIGHT 1000m max 165m max 40m max 50m max (40m max if outdoor installed below) 15m max

Page 146

Dimensions

PUHY-EP200, 300YHM-A
PUHY-EP200YHM-A schematic is the same as PUHY-P250, 300YHM-A on page 141 PUHY-EP300YHM-A schematic is the same as PUHY-P350, 400, 450YHM-A on page 141

PUHY-EP400, 450YSHM-A
Side View

>

Front View

>

PUHY-EP500, 550YSHM-A
Side View

>

Front View

>

PUHY-EP600, 650YSHM-A
Side View

>

Front View

>

Page 147

Y Series High COP (8-26hp)

City Multi Range 2008

Y Series High COP (28-36hp)


Heat Pump Outdoor Unit
Improved for even higher efficiency
The City Multi Y series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.
s s s s s s s s

Highest ever COPs / EERs due to new higher efficiency inverter technology and wrap around coil Choice of Branch Pipe or Header Pipe feeds to indoor units Energy-saving inverter driven outdoor compressor units with very low start currents No requirement for plant rooms or bulky service shafts Weight and size reduction compared to previous YGM-A models Improved pipe run of 165m, with a total system pipe length of 1000m 100% inverter control High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

Technical Information
Y SERIES HIGH COP OUTDOOR UNIT 28-36hp
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) POWER INPUT (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) COP/EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min) NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth (1650mm without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) RUNNING CURRENT (A) Heating Cooling FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores Height High PUHY-EP700YSHM-A 88.0 80.0 75.7 73.6 20.00 20.99 18.60 15.11 4.40 / 3.81 50 225 / 185 / 185 63 245 + 200 + 200 1220 + 920 + 920 760 1710 380-415v, 50Hz 3 8/8/8 30.9 32.4 32 / 20 / 20 4 + earth PUHY-EP750YSHM-A 95.0 85.0 81.7 78.2 22.19 21.79 20.64 15.69 4.28 / 3.90 50 225 / 185 / 185 63 245 + 200 + 200 1220 + 920 + 920 760 1710 380-415v, 50Hz 3 8/8/8 34.3 33.6 32 / 32 / 20 4 + earth PUHY-EP800YSHM-A 100.0 90.0 86.0 82.8 23.41 22.00 21.77 15.84 4.27 / 4.09 50 225 / 225 / 185 64 245 + 245 + 200 1220 + 1220 + 920 760 1710 380-415v, 50Hz 3 8/8/8 36.1 34.0 32 / 32 / 20 4 + earth PUHY-EP850YSHM-A 108.0 96.0 95.0 88.3 25.59 24.67 23.54 16.28 4.22 / 3.89 50 225 / 225 / 185 64 245 + 245 + 200 1220 + 1220 + 920 760 1710 380-415v, 50Hz 3 8/8/8 39.5 38.1 32 / 32 / 32 4 + earth PUHY-EP900YSHM-A 113.0 101.0 99.4 92.9 27.90 24.87 25.67 16.41 4.05 / 4.06 50 225 / 225 / 225 65 245 + 245 + 245 1220 +1220 + 1220 760 1710 380-415v, 50Hz 3 8/8/8 43.1 38.4 32 / 32 / 32 4 + earth

PUHY-EP700-900YSHM-A Piping Restrictions


TOTAL PIPING LENGTH FURTHEST PIPING LENGTH FURTHEST PIPING LENGTH AFTER 1st BRANCH BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT BETWEEN INDOOR AND INDOOR UNITS - HEIGHT 1000m max 165m max 40m max 50m max (40m max if outdoor installed below) 15m max

Page 148

Dimensions

PUHY-EP700, 750YSHM-A
Side View

>

Front View

>

PUHY-EP800, 850YSHM-A
Side View

>

Front View

>

PUHY-EP900YSHM-A
Side View

>

Front View

>

Page 149

Y Series High COP (28-36hp)

City Multi Range 2008

WY Series (8-20hp)
Heat Pump, Water Cooled Condensing Unit
The WY Series has all the benefits of the Y Series using water cooled condensing units. It is also able to produce heat recovery via the water circuit between heat source units, making for a very economical system.
s s s s s s s

High COPs possible thanks to increased efficiency and careful control of the system, allowing the largest operational water circuit temperature band ever Combining WY with waste heat energy provides unique application solutions Up to 24 indoor units can be connected to each condensing unit Condensing units can be situated indoors allowing greater design flexibility and no limitation on building size Single inverter compressor up to 20hp Improved pipe run of 150m with a total system pipe length of up to 300m High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants Now able to operate with closed loop ground source water temperatures, bore hole and slinky applications are now possible

Technical Information
WY SERIES HEAT SOURCE UNIT - 8-20hp
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) POWER INPUT (kW) Heating (nominal) Cooling (nominal) MAX No. OF CONNECTABLE INDOOR UNITS NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) RUNNING CURRENT (A) Heating Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores PQHY-P200YGM-A 25.0 22.4 4.69 4.79 13 46 272 990 550 1800 380-415v, 50Hz 3 8 7.2 7.4 20 4 + earth PQHY-P250YGM-A 31.5 28.0 5.80 5.95 16 47 275 990 550 1800 380-415v, 50Hz 3 8 8.9 9.1 25 4 + earth PQHY-P400YSGM-A 50.0 45.0 11.01 11.35 22 50 208 + 244 1980 550 1800 380-415v, 50Hz 3 8 17.0 17.5 40 4 + earth PQHY-P500YSGM-A 63.0 56.0 13.60 15.06 24 53 208 + 248 1980 550 1800 380-415v, 50Hz 3 8 21.0 23.3 50 4 + earth

PQHY-P200-500Y(S)GM-A Piping Restrictions


TOTAL PIPING LENGTH FURTHEST PIPING LENGTH FURTHEST PIPING LENGTH AFTER 1st BRANCH BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT BETWEEN INDOOR AND INDOOR UNITS - HEIGHT 300m max 150m max 40m max 50m max (40m max if outdoor installed below) 15m max

Page 150

Dimensions

PQHY-P200, 250YGM-A
Upper View

>

Left Side View

>
Front View

>

PQHY-P400, 500YSGM-A
Upper View

>

Left Side View

>
Front View

>
WY Series (8-20hp)
Page 151

City Multi Range 2008

R2 Series Standard (10-16hp)


Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit
Improved for even higher efficiency
Throughout the year, many buildings require cooling in some areas and heating in others even in adjacent rooms. The outstanding City Multi R2 system meets this requirement by distributing surplus heat from cooling operations (and vice versa) to rooms where it is needed. This efficiency can result in energy savings of up to 30% over conventional systems.
s s s s s s s

New higher efficiency inverter technology, with low start currents and wrap around coil for added efficiency Up to 40 indoor units connected to each outdoor unit Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than a 3 pipe equivalents Weight and size reduction compared to previous YGM-A models Improved pipe run of 165m with a total system pipe length of up to 600m 100% inverter control High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

Technical Information
R2 SERIES STANDARD OUTDOOR UNIT 10-16hp
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) POWER INPUT (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) COP/EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min) NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth (1650mm without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) RUNNING CURRENT (A) Heating Cooling FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores Height High PURY-P250YHM-A 31.5 28.0 28.7 26.6 7.83 7.73 7.75 4.79 4.02 / 3.62 25 185 57 235 920 760 1710 380-415v, 50Hz 3 8 12.1 11.9 32 4 + earth PURY-P300YHM-A 37.5 33.5 33.0 31.5 9.58 9.25 9.29 6.85 3.91 / 3.62 30 185 59 240 920 760 1710 380-415v, 50Hz 3 8 14.8 14.2 32 4 + earth PURY-P350YHM-A 45.0 40.0 39.6 37.6 12.47 12.47 12.10 9.23 3.60 / 3.20 35 225 60 265 1220 760 1710 380-415v, 50Hz 3 8 19.2 19.2 32 4 + earth PURY-P400YHM-A 50.0 45.0 44.0 42.3 13.71 13.74 13.30 10.17 3.64 / 3.27 40 225 61 265 1220 760 1710 380-415v, 50Hz 3 8 21.1 21.2 40 4 + earth

Note: For piping restrictions for PURY-P250-400YHM-A please see page 158 Page 152

Dimensions

PURY-P250, 300YHM-A

Upper View

>

Side View

>
Front View

>

PURY-P350, 400YHM-A

Upper View

>

Side View

>

Front View

>
R2 Series Standard (10-16hp)
Page 153

City Multi Range 2008

R2 Series Standard (20-32hp)


Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit
Improved for even higher efficiency
Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms. The outstanding City Multi R2 system meets this requirement by distributing surplus heat from cooling operations (and vice versa) to rooms where it is needed. This efficiency can result in energy savings of up to 30% over conventional systems.

s s s s s s s

New higher efficiency inverter technology, with low start currents and wrap around coil for added efficiency Up to 50 indoor units connected to each outdoor unit Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than a 3 pipe equivalents Weight and size reduction compared to previous YGM-A models Improved pipe run of 165m with a total system pipe length of up to 950m 100% inverter control High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

Technical Information
R2 SERIES STANDARD OUTDOOR UNIT 20-32hp
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) POWER INPUT (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) COP/EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min) NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth (1650mm without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) RUNNING CURRENT (A) Heating Cooling FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores Height High PURY -P500YSHM-A PURY -P550YSHM-A PURY -P600YSHM-A PURY -P650YSHM-A PURY -P700YSHM-A PURY -P750YSHM-A PURY -P800YSHM-A 63.0 56.0 54.8 51.5 16.79 16.75 15.28 11.73 3.75 / 3.34 50 185 / 185 60 235 + 235 920 + 920 760 1710 380-415v, 50Hz 3 8/8 25.9 25.8 32 / 32 4 + earth 69.0 63.0 60.0 58.0 18.81 18.68 17.12 13.08 3.66 / 3.37 50 185 / 185 61 240 + 235 920 + 920 760 1710 380-415v, 50Hz 3 8/8 29.0 28.8 32 / 32 4 + earth 76.5 69.0 66.6 63.5 20.83 19.64 18.96 13.75 3.67 / 3.51 50 185 / 185 62 240 + 240 920 + 920 760 1710 380-415v, 50Hz 3 8/8 32.1 30.3 32 / 32 4 + earth 81.5 73.0 70.9 67.2 22.55 22.80 20.52 15.96 3.61 / 3.20 50 225 / 185 62.5 265 + 240 1220 + 920 760 1710 380-415v, 50Hz 3 8/8 34.8 35.2 32 / 32 4 + earth 88.0 80.0 75.7 73.6 24.30 24.72 22.60 17.80 3.62 / 3.23 50 225 / 185 63 265 + 240 1220 + 920 760 1710 380-415v, 50Hz 3 8/8 37.5 38.2 40 / 32 4 + earth 95.0 85.0 81.7 78.2 26.36 27.86 24.51 20.06 3.60 / 3.05 50 225 / 225 63.5 265 + 265 1220 + 1220 760 1710 380-415v, 50Hz 3 8/8 40.7 43.0 40 / 32 4 + earth 100.0 90.0 86.0 82.8 27.64 29.75 25.71 21.42 3.61 / 3.02 50 225 / 225 64 265 + 265 1220 + 1220 760 1710 380-415v, 50Hz 3 8/8 42.7 45.9 40 / 40 4 + earth

Note: For piping restrictions for PURY-P500-800YSHM-A please see page 158 Page 154

Dimensions

PURY-P500, 550, 600YSHM-A


Side View

>

Front View

>

PURY-P650, 700YSHM-A
Side View

>

Front View

>

PURY-P750, 800YSHM-A

Page 155

R2 Series Standard (20-32hp)

Side View

>

Front View

>

City Multi Range 2008

R2 Series High COP (8-24hp)


Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit
Improved for even higher efficiency
Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms. The outstanding City Multi R2 system meets this requirement by distributing surplus heat from cooling operations (and vice versa) to rooms where it is needed. This efficiency can result in energy savings of up to 30% over conventional systems.
s s s

Highest ever COPs / EERs due to new high efficiency inverter technology and wrap around coil for added efficiency Up to 50 indoor units connected to each outdoor unit Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than a 3 pipe equivalents Weight and size reduction compared to previous YGM-A models Improved pipe run of 165m with a total system pipe length of up to 800m 100% inverter control with low start currents High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

s s s s

Technical Information
R2 SERIES HIGH COP OUTDOOR UNIT 8-24hp
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) POWER INPUT (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) COP/EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min) NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth (1650mm without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) RUNNING CURRENT (A) Heating Cooling FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores Height High PURY -EP200YHM-A PURY -EP300YHM-A PURY -EP400YSHM-A PURY -EP450YSHM-A PURY -EP500YSHM-A PURY -EP550YSHM-A PURY -EP600YSHM-A 25.0 22.4 23.0 21.3 5.81 5.23 5.75 3.24 4.30 / 4.28 20 185 57 235 920 760 1710 380-415v, 50Hz 3 8 8.9 8.0 20 4 + earth 37.5 33.5 33.0 31.5 9.37 8.33 9.09 6.16 4.00 / 4.02 30 225 60 265 1220 760 1710 380-415v, 50Hz 3 8 14.4 12.8 32 4 + earth 50.0 45.0 44.0 42.3 11.73 10.57 11.38 7.82 4.26 / 4.25 40 185 / 185 60 235 + 235 920 + 920 760 1710 380-415v, 50Hz 3 8/8 18.1 16.3 20 / 20 4 + earth 56.0 50.0 48.7 46.0 13.77 13.09 12.53 9.16 4.06 / 3.81 45 185 / 185 60 235 + 235 920 + 920 760 1710 380-415v, 50Hz 3 8/8 21.2 20.2 32 / 20 4 + earth 63.0 56.0 54.8 51.5 15.33 13.70 13.95 9.59 4.10 / 4.08 50 225 / 185 62 265 + 235 1220 + 920 760 1710 380-415v, 50Hz 3 8/8 23.6 21.1 32 / 20 4 + earth 69.0 63.0 60.0 58.0 17.37 16.38 15.81 11.47 3.97 / 3.84 50 225 / 185 62 265 + 235 1220 + 920 760 1710 380-415v, 50Hz 3 8/8 26.8 25.3 32 / 32 4 + earth 76.5 69.0 66.6 63.5 19.12 17.00 17.40 11.90 4.00 / 4.05 50 225 / 225 63 265 + 265 1220 + 1220 760 1710 380-415v, 50Hz 3 8/8 29.5 26.2 32 / 32 4 + earth

Note: For piping restrictions for PURY-EP200-600Y(S)HM-A please see page 158 Page 156

Dimensions

PURY-EP200, 300YHM-A
PURY-EP200YHM-A schematic is the same as PURY-P250, 300YHM-A on page 153 PURY-EP300YHM-A schematic is the same as PURY-P350, 400YHM-A on page 153

PURY-EP400, 450YSHM-A
Side View

>

Front View

>

PURY-EP500, 550YSHM-A
Side View

>

Front View

>

PURY-EP600YSHM-A
Side View

>

Front View

>

Page 157

R2 Series High COP (8-24hp)

City Multi Range 2008

R2 Series Piping Restrictions


R2 SERIES PIPING RESTRICTIONS

TABLE 1: TOTAL PIPE LENGTH OUTDOOR MODEL


P250, P300 P350, P400, EP200, EP300 P500, P550, EP400, EP450, EP500, EP550 P600, P650, EP600 P700, P750, P800
*1 Please refer to Graph 1

MAX LENGTH
550m*1 600m*1 750m*1 800m*1 950m*1

GRAPH 1: TOTAL PIPING LENGTH RESTRICTIONS


1000 900

Total Extended Pipe Length (m)

800 700 600


PURY-P600,650,800 YSHM-A, PURY-EP600YSHM-A PURY-P700,750,800 YSHM-A

500 400

PURY-P500,550 YSHM-A, PURY-EP400,450,500,550 YSHM-A PURY-P350,400 YHM-A, PURY-EP200,300 YHM-A

300 200 100 0 10 20 30 40 50 60 70 80 90 100 110

PURY-P250,300YHM-A

Distance Between Outdoor Unit and BC Controller (m)

R2 SERIES PIPING RESTRICTIONS

R2 SERIES PIPING RESTRICTIONS PIPING LENGTH (1 BC CONTROLLER, NO SUB BC CONTROLLER)

ITEM
Total Piping Length Furthest Piping Length Length Between OU and BC Length Between Furthest IU and BC Height Between OU and IU (OU above IU) Height Between OU and IU (OU below IU) Height Between IU and BC Height Between IU and IU
*1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.

PIPE SECTION
A+B+a+b+c+d A+B+d A B+d H H1 h1 h2

MAX LENGTH
(See Table 1) 165m 110m*1 60m*2 (40m) 50m 40m 15m 15m

Page 158

R2 SERIES PIPING RESTRICTIONS PIPING LENGTH (>1 BC CONTROLLER FOR 1 OUTDOOR UNIT)

ITEM
Total Piping Length Furthest Piping Length Length Between OU and BC Length Between Furthest IU and BC Height Between OU and IU (OU above IU) Height Between OU and IU (OU below IU) Height Between IU and BC Height Between IU and IU Height Between BC (Main or Sub) and BC (Sub)
*1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.

PIPE SECTION
A+B+C+D+E+a+b+c+d+e+f A+C+E+f A B+d or C+D+e or C+E+f H H1 h1 h2 h3

MAX LENGTH
(See Table 1) 165m 110m*1 60m*2 (40m) 50m 40m 15m 15m 15m

R2 SERIES PIPING RESTRICTIONS PIPING LENGTH (>1 BC CONTROLLER FOR 2 OUTDOOR UNITS)

ITEM
Total Piping Length Furthest Piping Length Length Between OU and BC Length Between Furthest IU and BC Height Between OU and IU (OU above IU) Height Between OU and IU (OU below IU) Height Between IU and BC Height Between IU and IU Height Between BC (Main or Sub) and BC (Sub) Length Between Main OU and Sub OU Height Between Main OU and Sub OU
*1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.

PIPE SECTION
F+G+A+B+C+D+E+a+b+c+d+e+f F(G)+A+C+E+f F(G)+A B+d or C+D+e or C+E+f H H1 h1 h2 h3 F+G or H h4

MAX LENGTH
(See Table 1) 165m 110m*1 60m*2 (40m) 50m 40m 15m 15m 15m 5m 0.1m

Page 159

R2 Series Piping Restrictions

City Multi Range 2008

WR2 Series (8-20hp)


Water Cooled Condensing Unit Simultaneous Heating and Cooling with Double Heat Recovery
The WR2 system has double heat recovery potential, making this system very economical. Not only does it produce heat recovery from indoor units on the same refrigerant circuit, it also produces heat recovery via the water circuit between heat source units.
s s s s s s s s s

All the benefits of the R2 Series with water cooled condensing units, using a single inverter compressor High COPs possible thanks to increased efficiency and careful control of the system, allowing the largest operational water circuit temperature band ever Unique 2-pipe refrigerant circuit allows simultaneous heating and cooling plus heat recovery between indoor units as with the R2 system Total building heat recovery made possible by exchanging energy in both refrigerant and water circuits Combining WR2 with waste heat energy provides unique application solutions Condensing units can be situated indoors allowing greater design flexibility and no limitation on building size Single inverter compressor up to 20hp Improved pipe run of 150m with a total system pipe length of up to 400m High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants Now able to operate with closed loop ground source water temperatures, bore hole and slinky applications are now possible

Technical Information
WR2 SERIES HEAT SOURCE UNIT - 8-20hp
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) POWER INPUT (kW) Heating (nominal) Cooling (nominal) MAX No. OF CONNECTABLE INDOOR UNITS NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) RUNNING CURRENT (A) Heating Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores PQRY-P200YGM-A 25.0 22.4 4.69 4.79 15 46 263 990 550 1800 380-415v, 50Hz 3 8 7.2 7.4 20 4 + earth PQRY-P250YGM-A 31.5 28.0 5.80 5.95 19 47 266 990 550 1800 380-415v, 50Hz 3 8 8.9 9.1 25 4 + earth PQRY-P400YSGM-A 50.0 45.0 11.01 11.35 24 50 208 + 232 1980 550 1800 380-415v, 50Hz 3 8 17.0 17.5 40 4 + earth PQRY-P500YSGM-A 63.0 56.0 13.60 15.06 24 53 208 + 236 1980 550 1800 380-415v, 50Hz 3 8 21.0 23.3 50 4 + earth

PQRY-P200-500Y(S)GM-A Piping Restrictions


TOTAL PIPING LENGTH FURTHEST PIPING LENGTH BETWEEN OUTDOOR AND BC CONTROLLER (MASTER) - LENGTH BETWEEN INDOOR AND BC CONTROLLER (MASTER/SLAVE) - LENGTH BETWEEN INDOOR AND OUTDOOR - HEIGHT BETWEEN INDOOR AND INDOOR - HEIGHT BETWEEN INDOOR AND BC CONTROLLER (MASTER/SLAVE) - HEIGHT BETWEEN INDOOR (MASTER) AND INDOOR (SLAVE) - HEIGHT 400m max*3 (300m) 150m max 110m max*4 (70m) 60m max*5 (40m) 50m max (40m)*1 15m max (10m)*2 15m max 15m max (10m)*2

*1 When O/U is below indoor *2 In case of P200, P250 indoor unit *3 Distance between outdoor unit and BC Controller is 70m or less *4 Total piping length is 300m or less *5 Height difference between the Master BC Controller and furthest indoor unit is zero

Page 160

Dimensions

PQRY-P200, 250YGM-A
Upper View

>

Left Side View

>
Front View

>

PQRY-P400, 500YSGM-A
Upper View

>

Left Side View

>
Front View

>
WR2 Series (8-20hp)
Page 161

City Multi Range 2008

PFD-P-VM-E (10/20hp)
Heat Pump Close Control System
Mitsubishi Electrics new Close Control System is specifically designed for computer rooms, laboratories etc, where a need for high sensible cooling and close control of temperature and humidity is required. Because of the need for close control 24 hours a day, 365 days a year, a newly developed inverter driven compressor has been incorporated into the outdoor unit, maximising the energy efficiency of the PFD series. It is also able to be connected to a computer network using our G50 controller, in order to monitor and provide remote email alarms.
s s s s s s s s

High sensible cooling Newly developed inverter driven compressor Energy efficient with high COPs Close control of temperature, 1C Easy to install - no service space needed at the rear of the unit Optional third party humidifier available Quick recovery following power failure Return or discharge air temperature control

Technical Information
PFD-P-VM-E - INDOOR UNIT
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) SHF POWER INPUT (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) AIRFLOW (m3/min) EXTERNAL STATIC PRESSURE (Pa) PIPE SIZE mm(in) Gas Liquid NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) RUNNING CURRENT (A) Inverter / DOL Heating Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores PFD-P250VM-E 31.5 28.0 29.1 26.6 0.93 2.5 2.5 2.15 2.15 160 120 22.2 (7/8) 9.52 (3/8) 59 380 1380 780 1950 380-415v, 50Hz 3 47 4.9 4.9 16 4 + earth PFD-P500VM-E 63.0 56.0 55.4 51.5 0.93 5.0 5.0 4.3 4.3 320 120 28.58 (1 1/8) 15.88 (5/8) 63 520 1980 780 1950 380-415v, 50Hz 3 68 8.7 8.7 20 4 + earth

PUHY-P-YHM-A / PQHY-P-YGM-A - OUTDOOR UNITS


PUHY-P250YHM-A PQHY-P250YGM-A PUHY-P250YHM-A x2 PQHY-P250YGM-A x2 31.5 28.0 28.7 26.6 N/A 6.6 6.8 6.55 4.2 185 N/A 22.2 (7/8) 9.52 (3/8) 57 200 920 760 1710 380-415v, 50Hz 3 8 10.2 10.5 32 4 + earth 31.5 28.0 N/A N/A N/A 5.6 5.9 N/A N/A N/A N/A 22.2 (7/8) 9.52 (3/8) 47 275 990 550 1800 380-415v, 50Hz 3 8 8.5 9.0 25 4 + earth 63.0 56.0 54.8 51.5 N/A 6.6 / 6.6 6.8 / 6.8 6.55 / 6.55 4.2 / 4.2 185 / 185 N/A 28.58 (1 1/8) 15.88 (5/8) 57 / 57 200 + 200 920 + 920 760 1710 380-415v, 50Hz 3 8/8 10.2 / 10.2 10.5 / 10.5 32 / 32 4 + earth 63.0 56.0 N/A N/A N/A 5.6 / 5.6 5.9 / 5.9 N/A N/A N/A N/A 28.58 (1 1/8) 15.88 (5/8) 47 / 47 275 + 275 990 + 990 550 1800 380-415v, 50Hz 3 8/8 8.5 / 8.5 9.0 / 9.0 25 / 25 4 + earth

PUHY-P-YHM-A / PQHY-P-YGM-A Piping Restrictions


TOTAL PIPING LENGTH BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT 165m max (150m for PQHY) 50m max (40m max if outdoor installed below)

Page 162

Dimensions

PFD-P250VM-E
Upper View

>

Side View Front View

>

>

PFD-P500VM-E
Upper View

>

Side View Front View

>

>
PFD-P-VM-E (10/20hp)
Page 163

City Multi Range 2008

PLFY-P-VBM-E
2, 3 and 4-Way Blow Ceiling Cassette Indoor Unit
Power cassettes offer 72 different airflow patterns, with the ability to handle a multitude of ceiling applications up to 4.2 meters in height. The easy to install, slim unit is ideal for maintaining constant temperatures, thanks to adjustable vanes that allow users to precisely direct air where its needed. The Mitsubishi Electric airflow control mechanism has been improved and uses wider vanes so that the unit reduces drafts and smudging, whilst a high performance drain pump on the drain lift mechanism allows drain water to be lifted up to 850mm from the ceiling surface.

Handy corner pocket design simplifies maintenance Airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed Reduced draft air distribution, with independent vane control Drain pump as standard, 850mm from drain pan Filter lowering operation down to 4m (optional PLP-6BAJ grille required) Optional I See Sensor for energy saving and smooth temperature control throughout the room For further information on the features of this cassette, please see page 60

s s
s s s s

Technical Information
PLFY -P-VBM-E - INDOOR UNIT
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) High Sensible SHF High Sensible POWER INPUT (kW) Cooling (UK) (UK) (UK) Heating (nominal) Cooling (nominal) AIRFLOW (m3/min) NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Lo-Mi1-Mi2-Hi Lo-Mi1-Mi2-Hi (Grille) Width (Grille) Depth (Grille) Height (Grille) ELECTRICAL SUPPLY PHASE RUNNING CURRENT (A) Heating Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores GRILLE MODEL REFERENCE PLFY-P32VBM-E 4.0 3.6 3.7 3.2 2.6 0.84 0.96 0.02 0.03 11-12-13-14 27-28-29-31 22(6) 840(950) 840(950) 258(35) 220-240v, 50Hz Single 0.14 0.22 6 3 PLP-6BA PLFY-P40VBM-E 5.0 4.5 4.6 4.0 3.3 0.83 0.91 0.03 0.04 12-13-14-16 27-28-30-31 22(6) 840(950) 840(950) 258(35) 220-240v, 50Hz Single 0.22 0.29 6 3 PLP-6BA PLFY-P50VBM-E 6.3 5.6 5.8 5.0 4.1 0.76 0.83 0.03 0.04 12-13-14-16 27-28-30-31 22(6) 840(950) 840(950) 258(35) 220-240v, 50Hz Single 0.22 0.29 6 3 PLP-6BA PLFY-P63VBM-E 8.0 7.1 7.4 6.3 5.2 0.75 0.79 0.04 0.05 14-15-16-18 28-29-30-32 23(6) 840(950) 840(950) 258(35) 220-240v, 50Hz Single 0.29 0.36 6 3 PLP-6BA PLFY-P80VBM-E 10.0 9.0 9.2 8.0 6.5 0.73 0.78 0.06 0.07 16-18-20-22 30-32-35-37 23(6) 840(950) 840(950) 258(35) 220-240v, 50Hz Single 0.43 0.51 6 3 PLP-6BA PLFY-P100VBM-E 12.5 11.2 11.6 10.0 8.1 0.73 0.79 0.14 0.15 21-24-27-29 34-37-39-41 27(6) 840(950) 840(950) 298(35) 220-240v, 50Hz Single 0.94 1.00 6 3 PLP-6BA PLFY-P125VBM-E 16.0 14.0 14.8 12.5 10.2 0.71 0.74 0.15 0.16 22-25-28-30 35-38-41-43 27(6) 840(950) 840(950) 298(35) 220-240v, 50Hz Single 1.00 1.07 6 3 PLP-6BA

Page 164

Dimensions

PLFY-P32, 40, 50, 63, 80, 100, 125VBM-E


Upper View

>

Lower View

>

Side View

>

MODELS PLFY-P32-80VBM-E PLFY-P100-125VBM-E

A 241 281

B 258 298

Page 165

PLFY-P-VBM-E

City Multi Range 2008

PLFY-P-VCM-E
600x600 4-Way Blow Ceiling Cassette Indoor Unit
The compact size of this unit is ideal for 600x600mm ceilings and with a depth of 208mm, this lightweight unit makes installation a breeze. This unit also comes complete with a long life filter that will last for approximately 2,500 hours.
s s s

Compact size for handy installation and easy maintenance Only 208mm high Fresh air duct facility

Technical Information
PLFY-P-VCM-E - INDOOR UNIT
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) High Sensible SHF High Sensible POWER INPUT (kW) Cooling (UK) (UK) (UK) Heating (nominal) Cooling (nominal) AIRFLOW (m3/min) NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Lo-Mi-Hi Lo-Mi-Hi (Grille) Width (Grille) Depth (Grille) Height (Grille) ELECTRICAL SUPPLY PHASE RUNNING CURRENT (A) Heating Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores GRILLE MODEL REFERENCE PLFY-P20VCM-E 2.5 2.2 2.3 2.1 1.6 0.86 1.00 0.05 0.05 8-9-10 28-31-35 15.5(3) 570(650) 570(650) 208(20) 220-240v, 50Hz Single 0.23 0.23 6 3 SLP-2AA PLFY-P25VCM-E 3.2 2.8 3.0 2.6 2.0 0.81 0.90 0.05 0.05 8-9-10 28-31-37 15.5(3) 570(650) 570(650) 208(20) 220-240v, 50Hz Single 0.23 0.23 6 3 SLP-2AA PLFY-P32VCM-E 4.0 3.6 3.7 3.4 2.6 0.76 0.85 0.06 0.06 8-9-11 29-33-38 17(3) 570(650) 570(650) 208(20) 220-240v, 50Hz Single 0.28 0.28 6 3 SLP-2AA PLFY-P40VCM-E 5.0 4.5 4.6 4.3 3.3 0.70 0.76 0.06 0.06 8-9-11 30-34-39 17(3) 570(650) 570(650) 208(20) 220-240v, 50Hz Single 0.28 0.28 6 3 SLP-2AA

Page 166

Dimensions

PLFY-P20, 25, 32, 40VCM-E

Lower View

>

Side View

>

Page 167

PLFY-P-VCM-E

City Multi Range 2008

PLFY-P-VLMD-E
2-Way Blow Ceiling Cassette Indoor Unit
The PLFY-P-VLMD-E cassette unit fits into the space in a suspended ceiling to provide heating or cooling. This new unit has been redesigned with lower unit height and lower noise levels.
s s s s

Light unit for ease of installation Terminal block on outside of unit for easy wiring Drain lift-pump mechanism as standard Newly designed decoration panel with air flow switching and swing functions as standard

Technical Information
PLFY-P-VLMD-E - INDOOR UNIT
MODEL REFERENCE
PLFYP20VLMD-E Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) High Sensible SHF High Sensible Cooling (UK) (UK) (UK) 2.5 2.2 2.3 2.1 1.6 0.81 0.94 0.065 0.072 6.5-8.0-9.5 27-30-33 23(6.5) 776(1080) 634(710) 290(20) 220-240v, 50Hz PHASE RUNNING CURRENT (A) Heating Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores GRILLE MODEL REFERENCE Single 0.30 0.36 6 3 CMP40VLW-B PLFYP25VLMD-E 3.2 2.8 3.0 2.6 2.0 0.77 0.85 0.065 0.072 6.5-8.0-9.5 27-30-33 23(6.5) 776(1080) 634(710) 290(20) 220-240v, 50Hz Single 0.30 0.36 6 3 CMP40VLW-B PLFYP32VLMD-E 4.0 3.6 3.7 3.4 2.6 0.74 0.81 0.065 0.072 6.5-8.0-9.5 27-30-33 24(6.5) 776(1080) 634(710) 290(20) 220-240v, 50Hz Single 0.30 0.36 6 3 CMP40VLW-B PLFYP40VLMD-E 5.0 4.5 4.6 4.3 3.3 0.67 0.73 0.074 0.081 7.0-8.5-10.5 29-33-36 24(6.5) 776(1080) 634(710) 290(20) 220-240v, 50Hz Single 0.34 0.40 6 3 CMP40VLW-B PLFYP50VLMD-E 6.3 5.6 5.8 5.3 4.1 0.70 0.73 0.075 0.082 9.0-11.0-12.5 31-34-37 27(7.5) 946(1250) 634(710) 290(20) 220-240v, 50Hz Single 0.35 0.41 6 3 CMP63VLW-B PLFYP63VLMD-E 8.0 7.1 7.4 6.7 5.2 0.72 0.77 0.094 0.101 10.0-13.0-15.5 32-37-39 28(7.5) 946(1250) 634(710) 290(20) 220-240v, 50Hz Single 0.43 0.49 6 3 CMP63VLW-B PLFYPLFYPLFYP80VLMD-E P100VLMD-E P125VLMD-E 10.0 9.0 9.2 8.5 6.5 0.71 0.77 0.140 0.147 15.5-18.5-22.0 33-36-39 44(12.5) 1446(1750) 634(710) 290(20) 220-240v, 50Hz Single 0.66 0.72 6 3 CMP100VLW-B 12.5 11.2 11.6 10.6 8.1 0.73 0.79 0.150 0.157 17.5-21.0-25.0 36-39-42 47(12.5) 1446(1750) 634(710) 290(20) 220-240v, 50Hz Single 0.69 0.75 6 3 CMP100VLW-B 16.0 14.0 14.8 13.2 10.2 0.73 0.80 0.27 0.28 24-27-30-33 40-42-44-46 56(13) 1708(2010) 606(710) 290(20) 220-240v, 50Hz Single 1.33 1.35 6 3 CMP125VLW-B

CAPACITY (kW)

POWER INPUT (kW) Heating (nominal) Cooling (nominal) AIRFLOW (m3/min) NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Lo-Mi1-Mi2-Hi Lo-Mi1-Mi2-Hi (Grille) Width (Grille) Depth (Grille) Height (Grille) ELECTRICAL SUPPLY

Page 168

Dimensions

PLFY-P20, 25, 32, 40, 50, 63, 80, 100VLMD-E


Front View

>

Upper View

>

Lower View

>

Side View

>

PLFY-P125VLMD-E
Side View

>

Upper View

>

Page 169

PLFY-P-VLMD-E

Rear View

>

Lower View

>

City Multi Range 2008

PMFY-P-VBM-E
1-Way Blow Ceiling Cassette Indoor Unit
Utilising a compact and lightweight body, the unit is perfect for applications where ceiling space is limited. A total body weight of 14kg makes it one of the lightest available, latest fan technology also makes it one of the quietest.
s s

Compact size for handy installation and easy maintenance Newly developed airflow control technology reduces noise levels to only 27dBA Drain lift pump mechanism allows the drain to be positioned anywhere up to 600mm from the ceilings surface Only 230mm high Fresh air duct facility

s s

Technical Information
PMFY-P-VBM-E - INDOOR UNIT
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) High Sensible SHF High Sensible POWER INPUT (kW) Cooling (UK) (UK) (UK) Heating (nominal) Cooling (nominal) AIRFLOW (m3/min) NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Lo-Mi1-Mi2-Hi Lo-Mi1-Mi2-Hi (Grille) Width (Grille) Depth (Grille) Height (Grille) ELECTRICAL SUPPLY PHASE RUNNING CURRENT (A) Heating Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores GRILLE MODEL REFERENCE PMFY-P20VBM-E 2.5 2.2 2.3 2.1 1.6 0.81 0.94 0.042 0.042 6.5-7.2-8.0-8.7 27-30-33-35 14(3) 812(1000) 395(470) 230(30) 220-240v, 50Hz Single 0.20 0.20 6 3 PMP-40BM PMFY-P25VBM-E 3.2 2.8 3.0 2.6 2.0 0.77 0.90 0.044 0.044 7.3-8.0-8.6-9.3 32-34-36-37 14(3) 812(1000) 395(470) 230(30) 220-240v, 50Hz Single 0.21 0.21 6 3 PMP-40BM PMFY-P32VBM-E 4.0 3.6 3.7 3.4 2.6 0.71 0.77 0.044 0.044 7.3-8.0-8.6-9.3 32-34-36-37 14(3) 812(1000) 395(470) 230(30) 220-240v, 50Hz Single 0.21 0.21 6 3 PMP-40BM PMFY-P40VBM-E 5.0 4.5 4.6 4.3 3.3 0.70 0.76 0.054 0.054 7.7-8.7-9.7-10.7 33-35-37-39 14(3) 812(1000) 395(470) 230(30) 220-240v, 50Hz Single 0.26 0.26 6 3 PMP-40BM

Page 170

Dimensions

PMFY-P20, 25, 32, 40VBM-E

Upper View

>

Lower View

>

Side View

>

Front View

>

Page 171

PMFY-P-VBM-E

City Multi Range 2008

PEFY-P-VMS1-E
Ultra Thin Ceiling Concealed Ducted Indoor Unit
The ultra thin ceiling concealed ducted indoor unit offers increased flexibility and is particularly suitable for places where low noise operation is desired from a slimline body.

s s s s s

Ultra thin body - height of only 200mm & width of only 790mm (P15-32) Extremely quiet operation - as low as 22dBA Cooling operation set temperature can be set down to 14C db Static pressure of 5-50Pa Now available in a size 15, ideal for hotel rooms

Technical Information
PEFY -P-VMS1-E - INDOOR UNIT
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) High Sensible SHF High Sensible POWER INPUT (kW) Cooling (UK) (UK) (UK) Heating (nominal) Cooling (nominal) AIRFLOW (m3/min) Lo-Mi-Hi PEFY-P15VMS1-E PEFY-P20VMS1-E 1.9 1.7 1.8 1.5 1.2 0.93 1.00 0.03 0.05 5.0-6.0-7.0 5-15-35-50 22-24-28 19 Width Depth Height ELECTRICAL SUPPLY PHASE RUNNING CURRENT (A) Heating Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores 790 700 200 220-240v, 50Hz Single 0.31 0.42 6 3 2.5 2.2 2.3 2.0 1.6 0.85 1.00 0.03 0.05 5.5-6.5-8.0 5-15-35-50 23-25-29 19 790 700 200 220-240v, 50Hz Single 0.36 0.47 6 3 PEFY-P25VMS1-E 3.2 2.8 3.0 2.5 2.0 0.84 0.90 0.04 0.06 5.5-7.0-9.0 5-15-35-50 24-26-30 19 790 700 200 220-240v, 50Hz Single 0.39 0.50 6 3 PEFY-P32VMS1-E 4.0 3.6 3.7 3.2 2.6 0.78 0.85 0.05 0.07 6.0-8.0-10.0 5-15-35-50 24-27-32 20 790 700 200 220-240v, 50Hz Single 0.39 0.50 6 3 PEFY-P40VMS1-E 5.0 4.5 4.6 4.0 3.3 0.75 0.82 0.05 0.07 8.0-9.5-11.0 5-15-35-50 28-30-33 24 990 700 200 220-240v, 50Hz Single 0.45 0.56 6 3 PEFY-P50VMS1-E 6.3 5.6 5.8 5.0 4.1 0.74 0.78 0.07 0.09 9.5-11.0-13.0 5-15-35-50 30-32-35 24 990 700 200 220-240v, 50Hz Single 0.56 0.67 6 3 PEFY-P63VMS1-E 8.0 7.1 7.4 6.3 5.2 0.75 0.79 0.07 0.09 12.0-14.0-16.5 5-15-35-50 30-33-36 28 1190 700 200 220-240v, 50Hz Single 0.61 0.72 6 3

EXTERNAL STATIC PRESSURE (Pa) Lo-Mi1-Mi2-Hi NOISE (dBA) (5Pa) WEIGHT (kg) DIMENSIONS (mm) Lo-Mi-Hi

Page 172

Dimensions

PEFY-P15, 20, 25, 32, 40, 50, 63 VMS1-E

Upper View

>

Side View

>

Front View

>

Model
PEFY-P15-32VMS1-E

E
7 9 11

F
600 800 1000

700 752 798 660 952 998 860 PEFY-P40-50VMS1-E 900 PEFY-P63VMS1-E 1100 1152 1198 1060

Page 173

PEFY-P-VMS1-E

City Multi Range 2008

PEFY-P-VMM-E
Ceiling Concealed Ducted Indoor Unit
The PEFY-P-VMM-E ducted indoor unit is concealed within the ceiling space to allow unobtrusive air conditioning. Flexibility of duct layout allows air flow patterns to be arranged to suit any application.

Reduced noise levels thanks to the use of a newly designed centrifugal fan - as low as 27dBA Drain lift-pump (option), 550mm of lift Complete flexibility in air conditioning design Cooling operation set temperature can be set down to 14C db

s s s

Technical Information
PEFY-P-VMM-E - INDOOR UNIT
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) High Sensible SHF High Sensible Cooling (UK) (UK) (UK) PEFYP20VMM-E 2.5 2.2 2.3 2.1 1.6 0.86 0.94 0.15 0.15 6.0-7.2-8.5 30-50-100 27-30-32 27 Width Depth Height ELECTRICAL SUPPLY 815 700 295 220-240v, 50Hz PHASE RUNNING CURRENT (A) Heating Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores Single 0.73 0.73 6 3 PEFYP25VMM-E 3.2 2.8 3.0 2.6 2.0 0.77 0.85 0.15 0.15 6.0-7.2-8.5 30-50-100 27-30-32 27 815 700 295 220-240v, 50Hz Single 0.73 0.73 6 3 PEFYP32VMM-E 4.0 3.6 3.7 3.4 2.6 0.76 0.85 0.17 0.17 7.5-9.0-10.5 30-50-100 28-32-35 27 815 700 295 220-240v, 50Hz Single 0.81 0.81 6 3 PEFYP40VMM-E 5.0 4.5 4.6 4.3 3.3 0.77 0.85 0.19 0.19 10-12-14 30-50-100 31-34-37 33 935 700 295 220-240v, 50Hz Single 0.92 0.92 6 3 PEFYP50VMM-E 6.3 5.6 5.8 5.3 4.1 0.75 0.83 0.20 0.20 12.0-14.5-17.0 30-50-100 31-35-38 33 935 700 295 220-240v, 50Hz Single 0.98 0.98 6 3 PEFYP63VMM-E 8.0 7.1 7.4 6.7 5.2 0.75 0.81 0.22 0.22 13.5-16.2-19.0 30-50-100 31-35-38 42 1175 700 295 220-240v, 50Hz Single 1.07 1.07 6 3 PEFYP80VMM-E 10.0 9.0 9.2 8.5 6.5 0.72 0.78 0.25 0.25 14.5-18.0-21.0 30-50-100 32-36-39 42 1175 700 295 220-240v, 50Hz Single 1.15 1.15 6 3 PEFYP100VMM-E 12.5 11.2 11.6 10.6 8.1 0.78 0.88 0.29 0.29 23-33 50-130 40-44 62 1415 740 325 220-240v, 50Hz Single 1.34 1.34 6 3 PEFYP125VMM-E 16.0 14.0 14.8 13.2 10.2 0.77 0.85 0.40 0.40 28-40 50-130 42-45 65 1415 740 325 220-240v, 50Hz Single 1.90 1.90 6 3

POWER INPUT (kW) Heating (nominal) Cooling (nominal) AIRFLOW (m3/min) Lo-Mi-Hi

EXTERNAL STATIC PRESSURE (Pa) - Lo-Mi-Hi NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Lo-Mi-Hi

Page 174

Dimensions

PEFY-P20, 25, 32, 40, 50, 63, 80VMM-E


Upper View

>

Model
PEFY-P20-32VMM-E PEFY-P40-50VMM-E PEFY-P63-80VMM-E

A
652 772 1012

B
245 305 280

C
290

710 684 830 804 1070 1044

Side View

>

Front View

>

PEFY-P100, 125VMM-E
Upper View

>
1252 370 360

370 1252 1284 1310

360

Side View

>

Front View

>
PEFY-P-VMM-E
Page 175

370 1252

360

City Multi Range 2008

PEFY-P-VMH-E
High Static Pressure Ceiling Concealed Ducted Indoor Unit
With improved design flexibility as a result of increased external static pressure, the PEFY-P-VMH-E allows authentic duct air conditioning within the strictest aesthetic confines.
s s s s s s

External static pressure of 200Pa Greater flexibility for duct extension, branching air outlet configuration Reduced noise levels thanks to the use of newly designed centrifugal fan Duct can be connected to intake side Drain lift-pump (option) 550mm of lift Cooling operation set temperature can be set down to 14C db

Technical Information
PEFY-P-VMH-E - INDOOR UNIT
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) High Sensible SHF High Sensible Cooling (UK) (UK) (UK) PEFY-P80VMH-E 10.0 9.0 9.2 8.5 6.5 0.74 0.83 0.32 0.32 18-25 100-150-200 38-43 50 Width Depth Height ELECTRICAL SUPPLY 1000 900 380 220-240v, 50Hz PHASE RUNNING CURRENT (A) Heating Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores Single 1.47 1.47 6 3 PEFY-P100VMH-E 12.5 11.2 11.6 10.6 8.1 0.80 0.91 0.48 0.48 26.5-38.0 100-150-200 38-44 70 1200 900 380 220-240v, 50Hz Single 2.34 2.34 6 3 PEFY-P125VMH-E 16.0 14.0 14.8 13.2 10.2 0.74 0.81 0.48 0.48 26.5-38.0 100-150-200 38-44 70 1200 900 380 220-240v, 50Hz Single 2.34 2.34 6 3 PEFY-P140VMH-E 18.0 16.0 16.6 15.1 11.6 0.74 0.82 0.48 0.48 28-40 100-150-200 38-44 70 1200 900 380 220-240v, 50Hz Single 2.35 2.35 6 3

POWER INPUT (kW) Heating (nominal) Cooling (nominal) AIRFLOW (m3/min) Lo-Hi

EXTERNAL STATIC PRESSURE (Pa) - Lo-Mi-Hi NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Lo-Hi

Page 176

Dimensions

PEFY-P80, 100, 125, 140VMH-E

Upper View

>

Side View

>

Page 177

PEFY-P-VMH-E

City Multi Range 2008

PCFY-P-VGM-E
Ceiling Suspended Indoor Unit
Designed for ultra-quiet operation and easy maintenance, the unit provides comfor table air conditioning for a wide range of applications where floor or wall space cannot be used practically.

s s s

Indoor unit designed for direct ceiling suspension Flush to wall installation for concealment of service connections Drain piping can be connected from left or right

Technical Information
PCFY-P-VGM-E - INDOOR UNIT
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) High Sensible SHF High Sensible POWER INPUT (kW) Cooling (UK) (UK) (UK) Heating (nominal) Cooling (nominal) AIRFLOW (m3/min) NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE RUNNING CURRENT (A) Heating Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores Lo-Mi1-Mi2-Hi Lo-Mi1-Mi2-Hi PCFY-P40VGM-E 5.0 4.5 4.6 4.3 3.3 0.72 0.79 0.10 0.10 8-10-11-12 29-33-36-38 27 1000 680 210 220-240v, 50Hz Single 0.46 0.46 6 3 PCFY-P63VGM-E 8.0 7.1 7.4 6.7 5.2 0.72 0.79 0.13 0.13 12-14-16-18 32-34-37-39 34 1310 680 210 220-240v, 50Hz Single 0.60 0.60 6 3 PCFY-P100VGM-E 12.5 11.2 11.6 10.6 8.1 0.71 0.77 0.16 0.16 18-20-23-25 36-38-41-43 37 1310 680 270 220-240v, 50Hz Single 0.73 0.73 6 3 PCFY-P125VGM-E 16.0 14.0 14.8 13.2 10.2 0.70 0.76 0.24 0.24 26-28-32-35 37-39-42-44 43 1620 680 270 220-240v, 50Hz Single 1.10 1.10 6 3

Page 178

Dimensions

PCFY-P40, 63, 100, 125VGM-E

Upper View

>

Front View

>

Lower View

>

Page 179

PCFY-P-VGM-E

City Multi Range 2008

PKFY-P-VBM-E/VGM-E/VFM-E
Wall Mounted Indoor Units
An elegant design combined with compact dimensions and quiet operation make the PKFY-P an ideal unit choice. Noise levels are significantly reduced thanks to a unique airflow passage design that not only makes the unit one of the quietest in the industry, but also suppresses condensation and prevents mixing with secondary air.
s s s s

Compact design - only 815mm wide (VBM-E) Front grille opening for easy cleaning Front power supply for easy wiring after installation 5-way piping provides more flexibility in selection of installation sites

Technical Information
PKFY-P-VBM-E / VGM-E / VFM-E - INDOOR UNIT
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) High Sensible SHF High Sensible POWER INPUT (kW) Cooling (UK) (UK) (UK) Heating (nominal) Cooling (nominal) AIRFLOW (m3/min) NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE RUNNING CURRENT (A) Heating Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores Lo-Mi1-Mi2-Hi Lo-Mi1-Mi2-Hi PKFY-P20VBM-E 2.5 2.2 2.3 2.1 1.6 0.71 0.75 0.04 0.04 4.9-5.2-5.6-5.9 29-31-34-36 10 815 225 295 220-240v, 50Hz Single 0.20 0.20 6 3 PKFY-P25VBM-E 3.2 2.8 3.0 2.6 2.0 0.73 0.80 0.04 0.04 4.9-5.2-5.6-5.9 29-31-34-36 10 815 225 295 220-240v, 50Hz Single 0.20 0.20 6 3 PKFY-P32VGM-E 4.0 3.6 3.7 3.4 2.6 0.79 0.88 0.07 0.07 8.0-9.5-10.5-11.5 33-36-38-41 16 990 235 340 220-240v, 50Hz Single 0.32 0.32 6 3 PKFY-P40VGM-E 5.0 4.5 4.6 4.3 3.3 0.74 0.82 0.07 0.07 8.0-9.5-10.5-11.5 33-36-38-41 16 990 235 340 220-240v, 50Hz Single 0.32 0.32 6 3 PKFY-P50VGM-E 6.3 5.6 5.8 5.3 4.1 0.72 0.78 0.07 0.07 9-10-11-12 34-37-40-43 16 990 235 340 220-240v, 50Hz Single 0.32 0.32 6 3 PKFY-P63VFM-E 8.0 7.1 7.4 6.7 5.2 0.78 0.85 0.12 0.12 15-20 39-45 24 1400 235 340 220-240v, 50Hz Single 0.55 0.55 6 3

Page 180

Dimensions

PKFY-P20, 25VBM-E
Front View

>

Right Side View

>

PKFY-P32, 40, 50VGM-E


Front View

>

Right Side View

>

PKFY-P63VFM-E
Front View

>

Right Side View

>

Page 181

PKFY-P-VBM-E / PKFY-P-VGM-E / PKFY-P-VFM-E

City Multi Range 2008

PFFY-P-VLRM-E
Floor Standing Concealed Indoor Unit
A compact concealed unit providing simple, effective air conditioning in perimeter zones. The unit is easy to install and at only 220mm deep offers an unobtrusive method of delivering highly efficient air-conditioning performance.

s s s

Concealed unit for hidden installation Ideal for perimeter refurbishments Cooling operation set temperature can be set down to 14C db

Technical Information
PFFY-P-VLRM-E - INDOOR UNIT
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) High Sensible SHF High Sensible POWER INPUT (kW) Cooling (UK) (UK) (UK) Heating (nominal) Cooling (nominal) AIRFLOW (m3/min) NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE RUNNING CURRENT (A) Heating Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores Lo-Hi Lo-Hi PFFY-P20VLRM-E 2.5 2.2 2.3 2.1 1.7 0.90 1.00 0.04 0.04 5.5-6.5 34-40 18.5 886 220 639 220-240v, 50Hz Single 0.19 0.19 6 3 PFFY-P25VLRM-E 3.2 2.8 3.0 2.6 2.0 0.81 0.95 0.04 0.04 5.5-6.5 34-40 18.5 886 220 639 220-240v, 50Hz Single 0.19 0.19 6 3 PFFY-P32VLRM-E 4.0 3.6 3.7 3.4 2.6 0.74 0.81 0.06 0.06 7-9 35-40 20 1006 220 639 220-240v, 50Hz Single 0.29 0.29 6 3 PFFY-P40VLRM-E 5.0 4.5 4.6 4.3 3.3 0.72 0.79 0.065 0.065 9-11 38-43 21 1006 220 639 220-240v, 50Hz Single 0.32 0.32 6 3 PFFY-P50VLRM-E PFFY-P63VLRM-E 6.3 5.6 5.8 5.3 4.1 0.74 0.80 0.085 0.085 12-14 38-43 25 1246 220 639 220-240v, 50Hz Single 0.40 0.40 6 3 8.0 7.1 7.4 6.7 5.2 0.73 0.79 0.10 0.10 12-15.5 40-46 27 1246 220 639 220-240v, 50Hz Single 0.46 0.46 6 3

Page 182

Dimensions

PFFY-P20, 25, 32, 40, 50, 63VLRM-E

Upper View

>

Front View

>

Side View

>

Page 183

PFFY-P-VLRM-E

City Multi Range 2008

PFFY-P-VLRMM-E
Floor Standing Concealed Indoor Unit
A compact concealed unit providing simple, effective air conditioning in perimeter zones. The unit is easy to install and at only 220mm deep offers an unobtrusive method of delivering highly efficient air-conditioning performance.

Reduced noise levels compared to the PFFY-P-VLRM-E version Cooling operation set temperature can be set down to 14C db Static pressure. The new unit has 3 static pressure settings - 20/40/60Pa ideal for ducting in the perimeter zone Concealed unit for hidden installation. The unit can be hidden behind a wardrobe in a hotel, then ducted above and below the wardrobe doors. This offers lower noise, less disruption and a low visual impact

Technical Information
PFFY-P-VLRMM-E - INDOOR UNIT
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) High Sensible SHF High Sensible POWER INPUT (kW) Cooling (UK) (UK) (UK) Heating (nominal) Cooling (nominal) AIRFLOW (m3/min) Lo-Mi-Hi PFFY-P20VLRMM-E 2.5 2.2 2.3 2.0 1.6 0.80 0.88 0.04 0.04 4.5-5.5-6.5 20-40-60 31-36-40 18.5 Width Depth Height ELECTRICAL SUPPLY PHASE RUNNING CURRENT (A) Heating Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores 886 220 639 220-240v, 50Hz Single 0.34 0.34 6 3 PFFY-P25VLRMM-E 3.2 2.8 3.0 2.5 2.0 0.76 0.80 0.04 0.04 4.5-5.5-6.5 20-40-60 31-36-40 18.5 886 220 639 220-240v, 50Hz Single 0.34 0.34 6 3 PFFY-P32VLRMM-E 4.0 3.6 3.7 3.2 2.6 0.75 0.81 0.04 0.04 6.5-7.5-9 20-40-60 27-32-37 20 1006 220 639 220-240v, 50Hz Single 0.38 0.38 6 3 PFFY-P40VLRMM-E 5.0 4.5 4.6 4.0 3.3 0.75 0.79 0.05 0.05 8-9.5-11 20-40-60 30-36-40 21 1006 220 639 220-240v, 50Hz Single 0.43 0.43 6 3 PFFY-P50VLRMM-E 6.3 5.6 5.8 5.0 4.1 0.76 0.80 0.05 0.05 10-12-14 20-40-60 32-37-41 25 1246 220 639 220-240v, 50Hz Single 0.48 0.48 6 3 PFFY-P63VLRMM-E 8.0 7.1 7.4 6.3 5.2 0.73 0.79 0.07 0.07 11-13-15.5 20-40-60 35-40-44 27 1246 220 639 220-240v, 50Hz Single 0.59 0.59 6 3

EXTERNAL STATIC PRESSURE (Pa) Lo-Mi1-Hi NOISE (dBA) (20Pa) WEIGHT (kg) DIMENSIONS (mm) Lo-Mi-Hi

Page 184

Dimensions

PFFY-P20, 25, 32, 40, 50, 63VLRMM-E

Upper View

>

Front View

>

Side View

>

Page 185

PFFY-P-VLRMM-E

City Multi Range 2008

PFFY-P-VLEM-E
Floor Standing Exposed Indoor Unit
A compact cased unit providing simple, effective air conditioning in perimeter zones. The unit is easy to install, and at only 220mm deep offers an unobtrusive method of delivering a highly efficient air-conditioning performance.
s s

Remote controller can be incorporated into the main unit Cooling operation set temperature can be set down to 14C db

Technical Information
PFFY-P-VLEM-E - INDOOR UNIT
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) High Sensible SHF High Sensible POWER INPUT (kW) Cooling (UK) (UK) (UK) Heating (nominal) Cooling (nominal) AIRFLOW (m3/min) NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE RUNNING CURRENT (A) Heating Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores Lo-Hi Lo-Hi PFFY-P20VLEM-E 2.5 2.2 2.3 2.1 1.7 0.90 1.00 0.04 0.04 5.5-6.5 34-40 23 1050 220 630 220-240v, 50Hz Single 0.19 0.19 6 3 PFFY-P25VLEM-E 3.2 2.8 3.0 2.6 2.0 0.81 0.95 0.04 0.04 5.5-6.5 34-40 23 1050 220 630 220-240v, 50Hz Single 0.19 0.19 6 3 PFFY-P32VLEM-E 4.0 3.6 3.7 3.4 2.6 0.74 0.81 0.06 0.06 7-9 35-40 25 1170 220 630 220-240v, 50Hz Single 0.29 0.29 6 3 PFFY-P40VLEM-E 5.0 4.5 4.6 4.3 3.3 0.72 0.79 0.065 0.065 9-11 38-43 26 1170 220 630 220-240v, 50Hz Single 0.32 0.32 6 3 PFFY-P50VLEM-E PFFY-P63VLEM-E 6.3 5.6 5.8 5.3 4.1 0.74 0.80 0.085 0.085 12-14 38-43 30 1410 220 630 220-240v, 50Hz Single 0.40 0.40 6 3 8.0 7.1 7.4 6.7 5.2 0.73 0.79 0.10 0.10 12-15.5 40-46 32 1410 220 630 220-240v, 50Hz Single 0.46 0.46 6 3

Page 186

Dimensions

PFFY-P20,25,32,40,50,63VLEM-E

Upper View

>

Front View

>

Side View

>

Page 187

PFFY-P-VLEM-E

City Multi Range 2008

PFFY-P-VKM-E
Floor Standing Exposed Indoor Unit
The PFFY-P-VKM-E series is extremely versatile and is designed for wall attached installation at floor level. The auto swing vane provides a more natural and comfortable airflow throughout the room and the lightweight, compact design makes installation easy.
s s

Pure white, slimline design Upper and lower vanes for optimum, powerful and efficient air distribution

Technical Information
PFFY-P-VKM-E - INDOOR UNIT
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) High Sensible SHF High Sensible POWER INPUT (kW) Cooling (UK) (UK) (UK) Heating (nominal) Cooling (nominal) AIRFLOW (m3/min) NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE RUNNING CURRENT (A) Heating Cooling FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores Lo-Mi1-Mi2-Hi Lo-Mi1-Mi2-Hi PFFY-P20VKM-E 2.5 2.2 2.3 2.1 1.6 0.81 0.88 0.025 0.025 5.9-6.8-7.6-8.7 27-31-34-37 15 700 200 600 220-240v, 50Hz Single 0.20 0.20 6 3 PFFY-P25VKM-E 3.2 2.8 3.0 2.6 2.0 0.77 0.85 0.025 0.025 6.1-7.0-8.0-9.1 28-32-35-38 15 700 200 600 220-240v, 50Hz Single 0.20 0.20 6 3 PFFY-P32VKM-E 4.0 3.6 3.7 3.4 2.6 0.71 0.77 0.025 0.025 6.1-7.0-8.0-9.1 28-32-35-38 15 700 200 600 220-240v, 50Hz Single 0.20 0.20 6 3 PFFY-P40VKM-E 5.0 4.5 4.6 4.3 3.3 0.70 0.76 0.028 0.028 8.0-9.0-9.5-10.7 35-38-42-44 15 700 200 600 220-240v, 50Hz Single 0.24 0.24 6 3

Page 188

Dimensions

PFFY-P20,25,32,40VKM-E
Upper View

>

Front View

>

Side View

>

Page 189

PFFY-P-VKM-E

City Multi Range 2008

GUF-50RD3 & GUF100RD3


Lossnay Outdoor Air Processing Indoor Unit
The GUF-50RD3 and GUF-100RD3 outdoor air processing units can be used with any of the extensive range of City Multi indoor units to provide ventilation, dust removal, humidification and heat recovery.
s s

A combination of a Lossnay & City Multi indoor in a single unit Air temperature in any room can be adjusted to the desired temperature via this unit which is used as an indoor unit of the City Multi air conditioning system The ventilating and air conditioning functions are integrated in a single unit, saving space and installation costs Heat recovery helps to save energy - a benefit thats not only good for the environment, but also great for cutting energy costs Free cooling is also available should outdoor conditions be suitable

Technical Information
OUTDOOR AIR PROCESSING INDOOR UNIT
MODEL REFERENCE
CAPACITY (kW) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) POWER INPUT (kW) AIRFLOW (m3/h) NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE RUNNING CURRENT (A) Lo-Hi Lo-Hi Lo-Hi GUF-50RD3 6.42 (2.25) 5.29 (1.66) 5.93 (2.08) 5.03 (1.58) 0.265 400-500 29.5-34.5 54 1016 1288 317 220-240v, 50Hz Single 0.70-1.15 6 3 GUF-100RD3 13.00 (4.70) 10.81 (3.49) 12.01 (4.34) 10.27 (3.32) 0.505 800-1000 34-39 92 1231 1580 398 220-240v, 50Hz Single 1.73-2.20 6 3

FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores

Attention
1. Nominal Condition: Cooling/Heating capacity indicates the value of operation under the following air condition and above air volume. Cooling: Indoor 27C DB/19.5C WB, Outdoor 35C DB/24C WB. Heating: Indoor 21C DB/14.6C WB, Outdoor 7C DB/6C WB. 2. UK Condition: Summer: Indoor 21C, Outdoor 27C Winter: Indoor 21C, Outdoor -1CWB 3. The figures in ( ) indicates the heat recovery at Lossnay core. 4. The current, input and efficiency are based on the above air volume. 5. The air nozzle noise (45 angle 1.5m ahead) is about 6dB greater than the indicated value. (High notch). 6. Specifications may be subject to change without notice.

Page 190

Dimensions

GUF-50/100RD3

Side View

>

Upper View

>

Front View

>
GUF-50RD3 and GUF100RD3
Page 191

City Multi Range 2008

PQFY-P
VRF Heat Pump Boiler
It is well known in the air conditioning industry that heat pumps are proven to provide highly efficient cooling. However, in line with other forward-thinking countries, such as Sweden and Switzerland, Mitsubishi Electric have now designed a heat pump boiler to provide heating and hot water, suitable for underfloor heating or swimming pools. Heat pump technology is largely untapped and offers great potential with incredible design flexibility, excellent use of energy and greatly reduced CO2 emissions.

An overview of the use of Heat Pump Boilers


The cooling operation of an air conditioning system that effectively extracts heat from a space, will normally be achieved at between 3.5 to 4.0 COP. This in itself is an efficient system. However, by recovering that heat and using it to heat up water the efficiency of the system increases dramatically to over 6.0 COP. Without the use of a Heat Pump Boiler, these levels of efficiency are rarely achieved in Spring and Autumn, when different rooms may need heating and cooling from the air conditioning at the same time. By using the VRF Heat Pump Boiler in a permanent heat recovery application, these efficiencies are now possible all year round. This provides a reduction in running costs and CO2 emissions, both of which play a crucial role when obtaining planning permission as covered by the new Part L2 Legislation. There is a further reduction in capital costs as there is very little or no requirement for gas boilers and associated works. Particularly when the small amount of heating required in order to boost domestic hot water from the 45C (produced by the heat pump), to the required 60C supply temperature, can be provided by means of electric. Thus negating the need for the installation of a gas supply entirely.

Technical Information
PQFY-P
MODEL REFERENCE
CAPACITY (kW) PIPE SIZE mm(in) Heating (nominal) Gas Refrigerant Liquid Refrigerant Water WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE MAINS CABLE No. Cores PQFY-P140 14.0 15.88 (5/8) 9.52 (3/8) 22 32 500 410 560 220-240v, 50Hz Single 3 PQFY-P250 25.0 19.05 (3/4) 9.52 (3/8) 28 50 610 510 560 220-240v, 50Hz Single 3

Unit Flow Rate & Pressure Drop


For calculating the Water Flow Rate please use the following calculation:
Capacity (kW) = Flow Rate of Water (l/s) x Specific Heat Capacity of Water x (Outlet Water Temp(C) - Inlet Water Temp (C)) Specific Heat Capacity of water is normally 4.2Kj/KgK PQFY-P140 Flow Rate Pressure Drop PQFY-P250 Flow Rate Pressure Drop l/s kPA 0.61 14.48 0.76 20.69 0.91 27.58 1.06 35.16 1.21 44.13 1.36 53.09 1.52 62.06 l/s kPA 0.38 11.72 0.45 15.86 0.53 20.69 0.61 25.51 0.68 30.34 0.76 36.54 0.83 42.75

Note: The water flow rate can be above or below these values, but no pressure drop operating data can be provided.

Page 192

Dimensions

PQFY-P140

Front View

>

Upper View

>

Front control panel not shown

PQFY-P250

Front View

>

Upper View

>

Front control panel not shown

Page 193

PQFY-P

City Multi Range 2008

BC Controllers
At the heart of both the R2 and WR2 Series, the BC controller makes simultaneous heating and cooling possible. It has the inherent intelligence to be the systems decision-maker.
s s s s

Transferring energy around the system Drawing on energy from the heat source units/outdoor units Directing energy as requested by the individual indoor units Instructs the heat source unit/outdoor unit on the amount of refrigerant (liquid or gas) that is required to achieve the requested cooling or heating requirements Allows unique 2-pipe heat recovery application HIC Circuit for improved efficiency

s s

Technical Information
BC CONTROLLERS
MODEL REFERENCE
NUMBER OF CONNECTIONS WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE POWER INPUT (KW) RUNNING CURRENT (A) FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores CMB-P104V-G 4 24 648 362 + 70 284 220-240v, 50Hz Single 0.085 0.36 6 3 CMB-P105V-G 5 27 648 362 + 70 284 220-240v, 50Hz Single 0.104 0.44 6 3 CMB-P106V-G 6 29 648 362 + 70 284 220-240v, 50Hz Single 0.123 0.52 6 3

Note: CMB-P-V-G units are for use with PURY-(E)P200-350 YHM-A & PQRY-P200/250YGM-A outdoor units only.

MASTER BC CONTROLLERS
MODEL REFERENCE
NUMBER OF CONNECTIONS WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE POWER INPUT (KW) RUNNING CURRENT (A) FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores CMB-P108V-GA 8 44 1110 450 + 70 289 220-240v, 50Hz Single 0.161 0.68 6 3 CMB-P1010V-GA 10 49 1110 450 + 70 289 220-240v, 50Hz Single 0.198 0.83 6 3 CMB-P1013V-GA 13 57 1110 450 + 70 289 220-240v, 50Hz Single 0.255 1.07 6 3 CMB-P1016V-GA 16 64 1110 450 + 70 289 220-240v, 50Hz Single 0.312 1.30 6 3 CMB-P1016V-HA 16 73 1110 450 + 70 289 220-240v, 50Hz Single 0.312 1.30 6 3

Note: CMB-P-V-GA units are for use with PURY-(E)P200-650Y(S)HM-A & PQRY-P200-500YSGM-A outdoor units only. CMB-P1016V-HA unit is for use with PURY-P700-800YSHM-A outdoor units only.

SLAVE BC CONTROLLERS
MODEL REFERENCE
NUMBER OF CONNECTIONS WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE POWER INPUT (KW) RUNNING CURRENT (A) FUSE RATING (BS88) HRC (A) MAINS CABLE No. Cores CMB-P104V-GB 4 22 648 362 + 70 284 220-240v, 50Hz Single 0.076 0.32 6 3 CMB-P108V-GB 8 32 648 362 + 70 284 220-240v, 50Hz Single 0.151 0.63 6 3 CMB-P1016V-HB 16 57 1098 362 + 70 284 220-240v, 50Hz Single 0.301 1.26 6 3

Note: CMB-P1016V-HB can be connected to a CMB-P1016V-HA.

Page 194

Dimensions

CMB-P104, 105, 106V-G


Upper View

>

Side View

>

CMB-P108, 1010, 1013, 1016V-GA/HA


Upper View

>

Side View

>

CMB-P104, 108V-GB
Upper View

>

Side View

>

A
CMB-P104V-GB CMB-P108V-GB 3 3

B
180 420

CMB-P1016V-HB
Upper View

>

Side View

>
BC Controllers
Page 195

City Multi Range 2008

PAC-AH-M-G/H Heat Pump & Cooling Only


Air Handling Unit Controller
The Air Handling Unit Controllers are an interface to allow connection to third party manufacturer equipment. Mitsubishi Electric City Multi outdoor units can be used with this interface box, creating an ideal solution when a unique air handling unit is required. The Air Handling Unit Controllers are supplied with LEV expansion device(s).

Technical Information
PAC-AH-M-H - HEAT PUMP AHU CONTROLLER
MODEL REFERENCE
MITSUBISHI ELECTRIC OUTDOOR UNIT AIR HANDLING UNIT SIZE ALLOWED EVAPORATOR CAPACITY (kW) - Heating ALLOWED EVAPORATOR CAPACITY (kW) - Cooling ALLOWED EVAPORATOR VOLUME (cm3) STANDARD EVAPORATOR PATH NUMBER* DIMENSIONS (mm) ( ) = Inc Mountings WEIGHT (kg) Width Depth Height PAC-AH125M-H P100 10.0 - 12.5 9.0 - 11.2 1500 - 2850 4 - 5 326 117 (132) 410 (430) 7 PAC-AH125M-H P125 12.5 - 16.0 11.2 - 14.0 1900 - 3550 4 - 5 326 117 (132) 410 (430) 7 PAC-AH140M-H P140 16.0 - 18.0 14.0 - 16.0 2150 - 4050 5 - 6 326 117 (132) 410 (430) 7 PAC-AH250M-H P200 18.0 - 25.0 16.0 - 22.4 3000 - 5700 6 - 10 326 117 (132) 410 (430) 7 PAC-AH250M-H P250 25.0 - 31.5 22.4 - 28.0 3750 - 7100 8 - 10 326 117 (132) 410 (430) 7 PUHY-(E)P200-1250Y(S)HM-A PUHY-(E)P200-1250Y(S)HM-A PUHY-(E)P200-1250Y(S)HM-A PUHY-(E)P200-1250Y(S)HM-A PUHY-(E)P200-1250Y(S)HM-A

PAC-AH-M-G - COOLING ONLY AHU CONTROLLER


MODEL REFERENCE
MITSUBISHI ELECTRIC OUTDOOR UNIT AIR HANDLING UNIT SIZE ALLOWED EVAPORATOR CAPACITY (kW) ALLOWED EVAPORATOR VOLUME (cm3) STANDARD EVAPORATOR PATH NUMBER* DIMENSIONS (mm) ( ) = Inc Mountings WEIGHT (kg) Width Depth Height PAC-AH140M-G P140 11.2 - 16.0 2150 - 4050 5 - 6 326 117 (132) 382 (420) 7 PAC-AH250M-G P200 15.9 - 22.4 3000 - 5700 6 - 10 326 117 (132) 382 (420) 7 PAC-AH250M-G P250 18.7 - 28.0 3750 - 7100 8 - 10 326 117 (132) 382 (420) 7 PU(H)(R)Y-(E)P200-1250Y(S)HM-A PU(H)(R)Y-(E)P200-1250Y(S)HM-A PU(H)(R)Y-(E)P200-1250Y(S)HM-A

Note: One air handling unit controller is required per air handling unit Saturated refrigerant temperature at exit of evaporator = 8.5C, SH=5K, liquid temperature = 25C, air = 27CDB/19CWB *When the diameter of the heat exchanger tube is 9.52

Example:

Air Handling Unit Controller (Mitsubishi Electric)

Controller (field supplied)

220-240v, 50Hz Power Supply

M-NET wiring

Thermistor wiring

Piping

Outdoor Unit (Mitsubishi Electric)

Air Handling Unit (field supplied)

Page 196

Accessories / Optional Extras


Outdoor Units

CMY-Y102S-G2 CMY-Y102L-G2 CMY-Y202-G2 CMY-Y302-G2 CMY-Y62-G-E CMY-Y100VBK2 CMY-Y200VBK2 CMY-Y300VBK2 CMY-R100VBK CMY-R200VBK ACH1 ACOUSTIC KIT

- Branch Pipe (Joint) for size 200 or below - total capacity of indoor units - Branch Pipe (Joint) for size 201-400 - total capacity of indoor units - Branch Pipe (Joint) for size 401-650 - total capacity of indoor units or first branch of P500-P650 - Branch Pipe (Joint) for size 651 or above - total capacity of indoor units or first branch of P700-P1250 - Branch Pipe for 2 branches (PUMY) - Twinning Kit for PUHY-P500-650YSHM-A / PUHY-EP400-650YSHM-A - Twinning Kit for PUHY-P700-900YSHM-A - Twinning Kit for PUHY-P950-1250YSHM-A / PUHY-EP700-900YSHM-A - Twinning Kit for PURY-P500-650YSHM-A / PURY-EP400-600YSHM-A - Twinning Kit for PURY-P700-800YSHM-A - PQFY Auto-Changeover controller - Acoustic kits for PUHY and PURY units

4-Way Blow Cassette Units

PLP-6BA SLP-2AA PLP-6BALM PLP-6BAJ PAC-SA1ME-E PAR-SA9FA-E S70E40714

- Grille for PLFY-P-VBM-E - Grille for PLFY-P-VCM-E - Grille and infra-red controller for PLFY-P-VBM-E - Grille with filter lowering function for PLFY-P-VBM-E - I -See Sensor corner panel for PLFY-P-VBM-E - Infra-red signal receiver for PLFY-P-VBM-E - Infra-red Controller (PAR-SL97A-E) for PLFY-P-VBM-E

2-Way Blow Cassette Units

CMP-P40VLW-B CMP-P63VLW-B CMP-P100VLW-B CMP-P125VLW-B PAC-KH11OF

Grille for PLFY-P20-40VLMD-E Grille for PLFY-P50-63VLMD-E Grille for PLFY-P80-100VLMD-E Grille for PLFY-P125VLMD-E OA duct flange for PLFY-P20-100VLMD-E

1-Way Blow Cassette Units Ceiling Concealed Ducted Units

PMP-40BM

- Grille for PMFY-P-VBM-E

PAC-KE03DM-F PAC-KE04DM-F PAC-KE88LAF PAC-KE89LAF PAC-KE80TB-F PAC-KE140TB-F

Drain lift-up mechanism for PEFY-P-VMM-E Drain lift-up mechanism for PEFY-P-VMH-E Long life filter for PEFY-P80VMH-E Long life filter for PEFY-P100-140VMH-E Filter box for PEFY-P80VMH-E (necessary when long life filter is used) Filter box for PEFY-P100-140VMH-E (necessary when long life filter is used)

BC Controllers

CMY-R160-J CMY-Y102S-G

- Joint pipe - Branch pipe

Indoor Units

PAC-SE41TS-E

- Remote sensor

Page 197

Air Handling Unit Controllers / Accessories

City Multi Range 2008

Lossnay
Total Heat Exchangers

Stale exhaust air Fresh air from outside

Heat exchange unit (Lossnay core)

Stale room air extracted

Fresh air supply to the room

Simple and
Excellent air quality and unbeatable Heat Exchange Efficiency
Poor air quality can be attributed to many problems arising in the workplace or in the home. It is believed to contribute to a significant loss in productivity, low morale and higher rates of sickness amongst many employees. The object of providing good ventilation alongside air conditioning in residential and commercial buildings is to provide conditions under which people can live and work in comfort and safety. Developed and refined over the past 30 years, the Lossnay system has perfected the recovery of waste energy. The units reduce overall energy costs by extracting stale air and then recovering the heating or cooling energy to either warm or cool incoming fresh air. By utilising this energy, the Lossnay system can save up to 30% on initial capital costs of heating and cooling plant.

Page 200

Effective
The Secret
of the Lossnay System
The secret of the Lossnay system lies in the cross flow, plate fin structure of the heat exchange unit. A diaphragm made of specially processed paper fully separates inlet and exhaust air supplies, ensuring that only fresh air is introduced to the indoor environment. The superior heat-transfer and moisture permeability of the special paper ensures highly efficient total heat exchange (temperature and humidity) when inlet and exhaust air supplies cross in the Lossnay element.

Page 201

Main features of

Lossnay
Effective ventilation
Lossnays simultaneous air exhaust/supply provides effective ventilation. Conventional ventilators (i.e. extract propeller fans) do not work effectively within air tight buildings because of the negative air pressures involved.

Good energy recovery


Total heat (sensible and latent) recovery provides a comfortable air temperature within the room. The energy saved by using Lossnay contributes towards lowering the heating or cooling requirement within the building, therefore reducing the energy requirement and running costs.

Free cooling function (LGH series)


When the outdoor temperature is lower than the indoor air conditioned temperature in the summer, Lossnay provides fresh outdoor cool air to reduce the indoor air temperature.

Good sound attenuation


As the Lossnay core is made of paper and the permeable holes are small, the Lossnay core provides outstanding soundproofing properties and is appropriate for sound proof rooms.

Part L2 Building Regulations


With the introduction of Part L2 (Part J in Scotland), new building design is changing to become more airtight, as well as energy efficient. The need for fresh air has remained the same however and thus poses new challenges for modern design. Lossnay fully meets these challenges due to its basic principal and its efficient heat recovery. See the Technical Information Section for CIBSE recommended fresh air rates.

Enhanced Capital Allowance (ECA)


LGH-RX4 now qualifies for Enhanced Capital Allowances.

Page 202

Total heat recover y

concept
Operation in winter
4.6C
Stale warm air (exhaust)

Operation in summer
25.6C
Stale cool air (exhaust)

15.4C
Fresh warm air (indoor supply air)

22.4C
Fresh cool air (indoor supply air)

0C
Fresh cool air (outdoor air)

20C
Stale warm air (indoor air)

Heating unit

27C
Fresh hot air (outdoor air)

21C
Stale cool air (indoor air)

Cooling unit

Using a Lossnay LGH-100RX4 in the winter example above, 8.9kW of heat is recovered per hour from the extracted air.

Page 203

Lossnay working in conjunction with air conditioning


Lossnay units can work either on their own to provide fresh air into a room, or in combination with Mr Slim or City Multi ceiling cassettes and ducted units.
When working together with air conditioning, Lossnay units can provide significant energy savings by automatically utilising free cooling as well as heat recovery. As the Lossnay and the air conditioning unit are connected by a two core communication cable, they can work together to optimise both comfort and energy efficiency. This is done by the Lossnay reading the mode and set temperature the air conditioning wants, then utilising the outside temperature to help achieve the required temperature either by free cooling or heat recovery. When using Lossnay in conjunction with air conditioning the heating and cooling loads can be reduced significantly, reducing the running costs by up to 30% compared with air conditioning systems without heat recovery systems.

Above example: One LGH25RX4 serving one PLA-RP71BA. Room size 7m x 7m, 140w/m2 heat load. 7 people per room, 10litres/per/person of fresh to meet Part F requirements. Maximum amount of fresh air to be introduced is 30% of the fan coil volume. Ceiling cassettes may require fresh air casements. Free cooling is not available below 8C when interlocked with Mr Slim or City Multi units. Lossnay fan speed button is incorporated within the standard PAR-21MAA and PAR-F27MEA controllers

The graph opposite shows the hourly temperature for 2006 in London between 8.00am - 6.00p.m. The point to note is the amount of free cooling available during these hours, as well as the heat recovery below (22% of the time) and cooling recovery above (20% of the time). Lossnay is a year round solution for providing fresh air.

Page 204

Free cooling provided by Lossnay was available in London over 58% of the time in 2006
Ambient Temperature - London 2006, 8am - 6pm

Over 58% of the time between 8am-6pm, the temperature in London was between 8C and 20C, allowing free cooling when the air conditioning setpoint was 21C in cooling mode. If the setpoint is higher, free cooling is increased.

Page 205

Hyper Lossnay Core


LGH-RX4 Lossnay units feature the newly developed Hyper Lossnay Core, which uses non-porous, ultra-thin film to achieve high enthalpy exchange efficiency. With a thickness of only 25m, these are the thinnest in the world and are approximately one fifth the thickness of previous Mitsubishi Electric products. Moisture permeability is dramatically increased and enthalpy heat exchange greatly improved.

Comparison of new and old Lossnay Core cross-sections


Previous Lossnay Core New Hyper Lossnay Core Comparison of material used in Hyper Lossnay Core (25m ultra-thin film) with regular paper
The thinnest paper used in regular printing is 51m thick (used in dictionaries) and the material of the Hyper Lossnay Core is approximately half the thickness of this.
Use Hyper Lossnay Core material Previous Mitsubishi Electric material Photocopier paper Dictionary paper Thickness 25m 120m 100m 51m

120m

25m

Porous partition plate

Non-porous film partition plate

Consists of a two-layer construction using a specially processed material made of a preferential permeable film on a porous base material. This provides moisture permeability and air barrier properties, but the two-layer construction makes a certain thickness unavoidable.

Consists of a specially processed structure based on a single-layer, non-porous, ultra-thin film material. Moisture exchange (water vapour transmission) is promoted by the special film, which increases the affinity for moisture (the thinner the film, the higher the permeability). The non-porous ultra-thin film material acts as a barrier against air leakage.

Connect ducts in two different directions (Outdoor vents)


Ducts can be connected in two different directions to the outdoor vents thanks to collars and aperture plates that can be interchangeably placed in two different positions. This flexibility allows for installations close to the surface of a wall and helps avoid cases where the stale air exhaust vent would be blocked by an obstruction of some kind. This makes both the planning and installation of Lossnay units that much simpler.

Standard installation
A space is necessary to prevent the influx of rainwater.

Installation with duct direction changed


Can be installed close to the surface of the wall.

Changing the duct direction

Interface simply

Collar

Aper ture Plate

Exchangeable

Because an adaptor now comes as standard equipment, networking LGH RX4 systems connected with Mitsubishi Electrics line of air conditioners has never been easier. There is no need to purchase any extra parts, creating the possibility of very simple systems and keeping initial costs as well as construction time and trouble to an affordable minimum.

Page 206

Multi-Ventilation Mode
Enables the appropriate supply/exhaust balance to be selected to suit usage, environment and location.
All LGH models feature the "Multi-ventilation Mode," which allows the air supply/exhaust balance to be varied dynamically to suit the usage environment and location. Modes can be selected easily by setting the connectors on the circuit board.
Ventilation Mode Supply Airflow High High Low Low Exhaust Airflow High Low High Low

Power air supply/exhaust mode Power air supply mode Power air exhaust mode Energy-saving ventilation mode

* "High" can be further set to "Extra high" using the dip switch.

Normal Office

Small Office or Building

Smoking Areas

Providing efficient ventilation while maintaining air supply/exhaust balance...

Using Lossnay compensates for using extractor fans...

Priority on air exhaust...

Power air supply & air exhaust


Most widely-used pattern forming the basis for traditional ventilation design. This allows the most efficient ventilation while maintaining the air supply/exhaust balance. The optimum ventilation rate can be maintained by selecting the Power air supply/exhaust mode with both the air supply & air exhaust switched to "High" (or "Extra high") on the main unit. For example in an office, the control switches can be set to "High" to run in Power air supply/exhaust mode when a large number of people are in the office, then switched to "Low" to run in Energy-saving ventilation mode late at night or on holidays when there are few people present.

Power air supply


In smaller offices or buildings, there may be insufficient air supply to the main rooms or offices due to the excessive exhaust via extractor fans located in toilets or kitchen areas. Setting to Power air supply mode with the air supply switch on "High" (or "Extra high") and the air exhaust switch on "Low" on the main unit, allows efficient ventilation while making up for the insufficient air supply.

Power air exhaust


In locations such as smoking areas, dirty air must be exhausted swiftly. Setting the Power air exhaust mode with the air supply switch on "Low" and the air exhaust switch on "High" (or "Extra high") on the main unit allows efficient extraction of cigarette smoke and odours. Maintaining the area at a negative air pressure also prevents dirty air from spreading to surrounding areas.

Page 207

Enhanced Capital Allowance & Part L2


The need for energy efficiency is paramount and is determined by legislation and regulation. To encourage efficient use of energy, the UK Government introduced the Enhanced Capital Allowance Scheme (ECA). The number of qualifying products on the Energy Technology Product List has recently been expanded and includes air to air energy recovery. The Lossnay heat recovery units (LGH-RX4) have been designed to ensure businesses qualify for ECA and benefit from the utmost efficiency, both financially and environmentally.

How Enhanced Capital Allowances Work


Enhanced Capital Allowances are used to encourage businesses to invest in particular types of equipment by providing up-front tax relief, as 100% of the allowances can be reclaimed in the first year. So, using the below example of a 1000 investment in equipment that qualifies for ECAs, the company could reclaim 300 in the first year.

Tax Rate % of expenditure to which allowance applies Equipment plus installation costs Taxable amount reduced by FIRST YEAR SAVING

Enhanced Capital Allowance 30% 100% 1000 100% OF 1000 = 1000 30% of 1000 = 300

Part L2
Part L2 of the Building Regulations is undergoing a major change. With building regulations tightened up from April 2006, new commercial buildings have to be pressure tested to show they are airtight and energy efficient. Proof will also be needed to show that the new buildings will not overheat and the occupants will be able to work comfor tably. This means that the fresh air requirements are even more important than ever before. Lossnay offers many features that will help the building designer as well as the occupants and with Lossnays high efficiency, unique controllability and its modular design approach, Lossnay will assist greatly in Part L2 compliance.

Page 208

Enhanced Capital Allowance Scheme (ECA)


The key features of the ECA scheme:
s Under the scheme, all businesses liable for UK corporation tax, are able to claim an enhanced capital allowance on any

qualifying expenditure (regardless of size and location of business or whether in the industrial or commercial sector)
s Businesses can offset the full cost of specific technologies (such as Lossnay)

against taxable profits of the period of the investment


s In order to qualify for this scheme, technology has to meet the energy saving criteria as published in the Energy

Technology Criteria List. Our LGH-RX4 Lossnay systems fully meet this criteria in their drive for energy efficiency
s Only investment in new and unused plant and machinery qualify

For further instructions go to www.eca.gov.uk and click on Mitsubishi Electric Air Conditioning under the air to air energy recovery category.

Page 209

Restaurants
A restaurant can never be too clean and its air never too fresh
The atmosphere of a restaurant is crucial to securing and retaining customers. Cleanliness is the key to an attractive atmosphere and restaurants devote significant effort to ensuring their premises are sanitary. Sanitation and cleanliness, however, are not enough. No matter how clean a restaurant may look, if there are bothersome odours lingering in the air, all those efforts go to waste and the restaurant's clean image is tarnished. For these reasons, Lossnays superior ventilation capabilities ensure that every breath is a fresh one and a pleasant environment is maintained for guests at all times. Lossnay also keeps owners happy with its remarkable heat recovery technology that supplies fresh outdoor air with minimal change to indoor temperature, saving on energy costs.

Schools
Creating the best possible environment for our children to succeed
Children deserve all the help we can give them to grow up healthy, happy and prosperous. No matter how good a school's curriculum, no matter how positive and enthusiastic the teacher, a child who does not feel well will have a hard time learning. A constant flow of fresh air is nowhere as important as it is in our schools. In classrooms where large numbers of students are gathered for long periods of time, carbonic gases have the tendency to accumulate, decreasing the levels of oxygen that are vital for alertness and concentration. This is especially true during the winter months when windows tend to remain closed. Lossnay ventilates fresh outdoor air into classrooms to replenish the supply of oxygen and expels not only carbon dioxide, but also other pollutants and odours that inevitably sully the air.

If its Lossnay
Lossnay works to remove stale air and supply fresh, clean air free of the odours associated with cooking, cigarettes and the people working and dining. Change in room temperature is kept to a minimum during ventilation thanks to the heat-recovery function. The Lossnay operate very quietly, so those in the midst of enjoying their meals will not be bothered by any excess noise. A large array of Lossnay sizes are available to match the layout of just about any restaurant.

If its Lossnay
The continuous influx of fresh, outdoor air and the exhaust of stale, indoor air ensure that the indoor oxygen level is maintained at just the right balance for comfort and health. Occupants have the luxury of breathing fresh air at all times even in highly air-tight buildings. Lossnay's sound attenuation qualities prevent outside noise from penetrating into the room, helping to maintain a quiet environment for productive study. Heat-exchange technology prevents fluctuations in temperature creating significant energy savings when either heating or cooling a room.
O2 Concentration and Deficiency
21 % 21 18 % 16 %

What would you most like to see improved in restaurants?

52.3%
O2 Concentration (%)
Improvement in overall cleanliness
Others: no response Promotion of waste prevention: 5.4% Improvement in atmosphere: 6.5% Reduction of time required for food to reach the table: 12.0% Improvement in employees attitude towards customers: 20.5% 1996 Foodstuffs Consumption Monitor, Second Periodic Survey ( Ministry of Agriculture, Forestry and Fisheries, Japan)

15 12 %
Increased respiration and pulse

Paleness of skin, vomiting, Unconsciousness

10
Safety minimum

Dizziness, nausea, loss of muscle strength (precursors of death)

10 %

8%
Comatosis (death in 8 min)

Normal air

6%
Convulsions, respiration stops, death

5 0

Page 210

Lossnay Selection / Payback Software and Quick Reference Guide available to order from your local sales office

Offices
Fresh air - improving the overall quality of working life
Many office buildings today are heavily insulated, air-tight structures with little or no natural ventilation. The unnatural environment created by air conditioners without added ventilation is a breeding ground for bacteria. Factor this in with the accumulation of pollutants and odours in the form of cigarette smoke, formaldehyde, pollen, dust, carbon dioxide and the necessity of ventilation becomes ever more apparent. In fact, poorly ventilated buildings can give rise to Sick Building Syndrome, a malady that is known to cause headaches, sore eyes, itching and loss of concentration. This results not only in discomfort at best and sickness at worst for the building's occupants, but also the reduced productivity of the workforce. Fresh air, effectively ventilated throughout the building is therefore essential to the overall quality of working life.

If its Lossnay

Simultaneous forced-air supply and exhaust introduces fresh, outdoor air into the building, effectively ventilating even fully airtight structures. Multiple split-type units operate independently of one another, simplifying system set up and ensuring a layout that optimally matches nearly any office design. Lossnay operation can be interlocked with air-conditioning system operation. Heat that is commonly lost due to ventilation is collected and reused thanks to the Lossnay Core, reducing an air conditioners energy load and cutting operating costs.

Page 211

The unbeatable

Lossnay
The Lossnay allows the extraction of stale air and efficient recover y of heating or cooling energy to treat incoming fresh air. Whatever your environment, its simple to improve it with Lossnay.

Simple technology
at its best
Systems marked with the ECA logo are registered on the Energy Technology List and hence qualify for 100% first year enhanced capital allowances (whole system cost and reasonable cost of installation). For further information please go to www.eca.gov.uk

Nominal conditions cooling: indoor 27C DB, 19C WB; outdoor 35C DB, 24C WB. Nominal conditions heating: indoor 20C DB; outdoor 7C DB, 6C WB. UK Conditions: Summer; indoor 21C DB, 15C WB; outdoor 27C DB. Winter; indoor 21C DB; outdoor -1C WB.

Page 212

Contents
214

Total Heat Exchangers Residential Model LGH-RX4 Commercial Series

216

180

182

Page 213

Total Heat Exchangers


Residential Model
Particularly suitable for modern homes with high insulation afforded by double glazing and cavity insulation, which require ventilation to remove stale air without major heat loss.
s s s s

Effective fresh air ventilation Efficient recovery of heating/cooling energy Good sound attenuation Reduces heating costs

Technical Information
LOSSNAY
MODEL REFERENCE ELECTRICAL POWER SUPPLY PHASE POWER CONSUMPTION (W) Low High AIRFLOW (m3/h) Low High NOISE (dBA) Low High TEMPERATURE EXCHANGE EFFICIENCY (%) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height DUCT SIZE (mm)
FUSE RATING (BS88) - HRC (A) RESIDENTIAL WALL- MOUNTED VL 100U

220 - 240V, 50Hz Single 23 26 65 105 29.5 39 77 70 6.5 620 168 265 2x75 6 3

Low High

MAINS CABLE No. Cores

Page 214

VL 100U
Dimensions

Page 215

Total Heat Exchangers Residential Model

Lossnay Range 2008

LGH-RX4
Commercial Series
This commercially orientated system can be utilised virtually anywhere.
s s s s s

Effective fresh air ventilation High heat recovery Free cooling function Good sound attenuation New Hyper Lossnay Core. At only 25m (approx 1/5 the thickness of LGH-RX3) the Lossnay core uses the thinnest paper in the world to achieve high enthalpy exchange efficiency

Stale exhaust air Fresh air from outside

Heat exchange unit (Lossnay core)

Stale room air extracted

Fresh air supply to the room

Technical Information
LOSSNAY
MODEL REFERENCE
ELECTRICAL POWER SUPPLY STARTING CURRENT (A) RUNNING CURRENT (A) Low High Extra High INPUT POWER (W) Low High Extra High Low AIRFLOW (m3/h) High / Extra AIRFLOW (l/s) Low High / Extra EXTERNAL STATIC Low PRESSURE (PA) High Extra High NOISE (dBA) Lossnay Low High Extra High Bypass Low High Extra High TEMPERATURE Low EXCHANGE High EFFICIENCY (%) Extra High ENTHALPY Heating Low EXCHANGE High / Extra EFFICIENCY (%) Cooling Low High / Extra WEIGHT (kg) DIMENSIONS (mm) Width Depth Height DUCT SIZE (mm) *1 STANDARD FILTER FUSE RATING (BS88) HRC (A) MAINS CABLE NO. CORES

COMMERCIAL LGH-15RX4
220-240V, 50Hz 0.7 0.22 0.31 0.45 51 73 107 110 150 31 42 35 60 95 23 25 27 23 25 27 81 77 77 74 70 70 64.5 17 610 780 275 100 EU3 6 3

COMMERCIAL LGH-25RX4
220-240V, 50Hz 0.8 0.25 0.40 0.49 59 96 117 165 250 46 69 25 50 80 23 26 27.5 23 26.5 28 83.5 78 78 77 70 71 65 21 735 780 275 150 EU3 6 3

COMMERCIAL LGH-35RX4
220-240V, 50Hz 1.7 0.48 0.71 0.79 110 167 187 230 350 64 97 25 70 150 24 30 32 24 30 32.5 84 79 79 77 70 74.5 68 30 874 888 317 150 EU3 6 3

COMMERCIAL LGH-50RX4
220-240V, 50Hz 1.9 0.60 0.90 0.95 142 214 225 350 500 97 139 30 60 150 24.5 31.5 34 25.5 33 35.5 82 77 77 73.5 67.5 71.5 64.5 33 1016 888 317 200 EU3 6 3

COMMERCIAL LGH-80RX4
220-240V, 50Hz 3.6 1.40 1.60 1.70 315 370 385 670 800 186 222 70 100 140 31 33 34.5 31.5 34 35.5 80.5 78 78 73.5 71 70.5 67 61 1004 1164 398 250 EU3 6 3

COMMERCIAL LGH-100RX4
220-240V, 50Hz 5.4 1.70 2.00 2.10 400 475 490 870 1000 242 278 80 100 160 32.5 35 37 34 36.5 38 81 79 79 74 71 69.5 67 69 1231 1164 398 250 EU3 10 3

COMMERCIAL LGH-150RX4

COMMERCIAL LGH-200RX4

High High

High High

220-240V, 50Hz 220-240V, 50Hz 7.2 10.8 2.70 3.50 3.10 4.20 3.30 4.30 625 820 730 980 770 1010 1250 1650 1500 2000 347 458 417 556 70 65 100 90 140 150 33.5 36 36.5 38 37.5 40 36.5 37 38.5 39.5 40 41 81.5 81.5 79 79 79 79 74.5 75 72 71 72 71 68 67 124 140 1004 1231 1164 1164 800 800 (SA,RA)250 (OA,EA)270x700 (SA,RA)250 (OA,EA)270x700 EU3 EU3 16 16 3 3

Notes: Running Current, Input Power and Recovery Efficiency are based on the above airflow rate, power supply 240v, 50Hz. Extra High mode available via dip switch setting. Noise measured at 1.5m under the centre of panel. *1: Eu7 filter available as optional parts.

Page 216

Dimensions

LGH-15RX4 to LGH-200RX4

M-NET Controller PZ-52SF-E (M-NET)


Control 16 Lossnay units from sizes 15 -100 or up to 8, sizes 150 - 200

Lossnay Controller PZ-41SLB-E


Control 15 Lossnay units from sizes 15 -100 or up to 7, sizes 150 - 200

70

33

70

33

48

48

LGH-15-100RX4

>

LGH-150-200RX4

>

MODEL REFERENCE
A LGH-15RX4 LGH-25RX4 LGH-35RX4 LGH-50RX4 LGH-80RX4 LGH-100RX4 780 780 888 888 1164 1164 A 1004 1231

DIMENSIONS B 610 735 874 1016 1004 1231 B 690 920

C 275 275 317 317 398 398 C 1046 1273

CEILING SUSPENSION FIXTURE PITCH D E 700 700 790 790 1030 1030 641 765 906 1048 1036 1263

NOMINAL DIAMETER 100 150 150 200 250 250

MODEL REFERENCE
LGH-150RX4 LGH-200RX4

Page 217

LGH RX4 Commercial Series

Lossnay Range 2008

120

120

Controls
A comprehensive range of control options

The importance of
The need for control is paramount in order to optimise the performance of any air conditioning system and minimise its running costs. Mitsubishi Electric offer a wide range of control options designed to do just this.
Operating an air conditioning system without the right control can prove costly. Its therefore important to ensure that every system is correctly specified to the degree of control it requires. Mitsubishi Electric have a wide range of controls available off-the-shelf and where needed, individual control systems can be specifically designed to suit. Good controls will benefit any application, large or small. Air conditioning products need to react to a variety of factors: different room sizes, usage and staff levels; changes in the climate; electronic equipment and lighting ... the list goes on. So whatever the application, optimum control of air conditioning systems is essential and will result in a constant, comfortable environment, which in turn is both energy and cost efficient.

A degree of

difference
When an air conditioning system is not properly controlled, it will not run as efficiently as it should. For every degree that the system deviates from the required temperature, energy costs can rise by up to 5%. Specify one of the many control options from Mitsubishi Electric to ensure air conditioning works as intended, whilst giving the optimum amount of control.

The simpler

the better
With the array of comprehensive control systems available from Mitsubishi Electric, it becomes simple to design and install air conditioning systems. From a simple hand held controller to a G50 system - you are in control.

Page 220

Control
Controlled
In accordance with the requirements of part L2 in the Building Regulations, our control systems provide the optimum control available, combined with the most efficient use of energy.

performance

A wide range of

Controls options
The need for control is paramount in order

to optimise the performance of any air conditioning

system and minimise its running costs.

Mitsubishi Electric offer a wide range of

control options designed to do just this.

Simple technology
at its best

Page 222

Contents
224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254

Remote Controllers Programmable Timer System Controller Interfaces G50 Controller, Centralised Controller AG150 Controller, Centralised Controller GB50 Controller, Centralised Controller G50/GB50/AG150 Controller, Web Screenshots G50/GB50/AG150 Desktop Remote Controller G50/GB50/AG150 Third Party Equipment Interfaces G50/GB50/AG150 Programmable Logic Controller (PLC) TG2000 Software, PC Based Software Package TG2000 Software with Energy Monitoring TG2000 Software with Third Party Equipment TG2000 WAN Software (Wide Area Network) TG2000, Screenshots BEMS BACnet Interface (BAC-IP/50) BEMS BACnet Mr Slim Interface (BAC-A/50) BEMS LonWorks Interface (LMAP) BEMS Modbus Interfaces (IP-32/50/100M) BEMS Modbus Mr Slim Interface (A32M) BEMS Modbus Splits Interface (A1M) BEMS KNX-EIB Interfaces (KNX-EIB-IP-15/100) BEMS KNX-EIB Splits Interface (KNX-EIB-A-1) M2M - Machine 2 Machine Interface (Maxi M2M-IP/50) M2M - Machine 2 Machine Splits Interface (Mini M2M-A/16) M2M - Machine 2 Machine Web Screenshots G50 Control Panels Run / Standby Control Panels Energy Monitoring Control Panels Split-System A2M Interfaces

Page 223

Remote Controllers
Our air conditioning systems are supported by a multitude of remote controllers. Each remote controller type, whilst being able to support the general control and monitoring functions for a group of indoor units, can also offer other unique operational features.

PAC-YT51CRA

PAC-SE51CRA

BS-51COV

PC-51COV

PB-51COV

PAR-21MAA

PAR-F27MEA

PAR-FL32MA

Technical Information
Remote Controllers
FUNCTION DESCRIPTION PAC-YT51CRA PAC-SE51CRA
Operation Display Operation Display

PAR-21MAA
Operation Display

PAR-F27MEA
Operation Display

PAR-FL32MA
Operation Display

ON/OFF MODE SELECTION

Run and Stop operation for a single group Switches between Cool/Dry/Auto/Fan/Heat. Operation mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems Sets the groups temperature control. Cool/Dry: 19-30C Heat: 17-28C Auto: 19-28C 4 speed - Lo-Mi1-Mi2-Hi 2 speed - Lo-Hi Limit the setpoint range Air Flow angles:100-80-60-40 and auto swing Only available with PLA-RP-BA, PLFY-P-VBM-E and PLFY-P-VCM-E ON/OFF time can be set. Run/Stop, Temperature Setting, Mode Selection and Filter Reset functions can be prohibited via a higher level system controller Measures the intake temperature of the master unit within the group Displays a 4 digit code and the affected unit address Allows each unit within the group to operate in test mode Allows the group to be interlocked with a heat recovery Lossnay unit Brushed Stainless Steel Polished Chrome Polished Brass Displays under fault condition, the fault code of the unit with its address and the contact number to call English, Italian, Spanish, French, German, Russian, Chinese and Japanese Displays time Able to lock all controller buttons, or all controller buttons except On/Off Able to monitor information about the compressor (running current, running time, On/Off time). Also able to monitor sensors: h-exh, outdoor outlet, outdoor temp, indoor inlet, indoor h-exh and filter use number of hours Able to switch over two systems every week. If one fails, the other system starts. If the temperature is too high, the two systems start. Compatible with: Mr Slim or M Series (via MAC-397IF) 120x41x70 City Multi Mr Slim or M Series (via MAC-397IF) 130x19x120 City Multi City Multi, Mr Slim or M Series (via MAC-397IF) 157x18x57 Weekly Weekly Daily Daily Daily Daily

TEMPERATURE SETTING

FAN SPEED SETTING SETPOINT LIMIT AIRFLOW DIRECTION INDEPENDENT VANE CONTROL TIMER OPERATION PERMIT / PROHIBIT FUNCTION INDOOR RETURN AIR TEMPERATURE ERROR INDICATION TEST RUN FUNCTION VENTILATION INTERLOCK OPTIONAL COVER

CONTACT NUMBER UNDER FAULT CONDITIONS MULTIPLE LANGUAGES CLOCK DISPLAY BUTTON LOCK EASY MAINTENANCE WITH MR SLIM

RUN / STANDBY WITH MR SLIM COMPATIBILITY DIMENSIONS - mm (WxDxH)

120x41x70

130x19x120

Page 224

Programmable Timer
Mitsubishi Electric controllers are complimented by a weekly programmable timer, being able to control up to fifty indoor units. The PAC-YT34STA also has hardwired connection available (On/Off input, fire alarm input, run output, fault output).

PAC-YT34STA

PAC-YT34STA

PAC-SC50KUA

Technical Information
Programmable Timer
FUNCTION UNITS DESCRIPTION
Max No. of Indoor Units 50 units/50 groups Operation

PAC-YT34STA
50 units/50 groups Display

ON/OFF MODE SELECTION TEMPERATURE SETTING

Run and Stop operation Switches between Cool / Heat Sets the groups temperature control. Cool/Dry: 19-30C Heat: 17-28C Auto: 19-28C Set the time Displays a 4 digit code and the affected unit address Hardwired connections available Hardwired connections available Compatible with: On/Off or Fire Alarm Run/Faults City Multi or Mr Slim via PAC-SF80MA or M Series via MAC-399IF 130x19x120

CURRENT TIME ERROR INDICATION EXTERNAL INPUT EXTERNAL OUTPUT COMPATIBILITY DIMENSIONS - mm (WxDxH)

NOTE: Units can only be controlled from the scheduling options. When the remote On/Off hardwired input is used, the On/Off remote controller buttons will be deactivated (centrally controlled).

Page 225

Remote Controllers / Programmable Timer

Controls Range 2008

System Controller
One system controller is available for use when you need to control up to fifty indoor units from one location. The PAC-SF44SRA also has hardwired connection available (On/Off input, fire alarm input, run output, fault output).

PAC-SF44SRA

PAC-SF44SRA

PAC-SC50KUA

Technical Information
System Controller
FUNCTION UNITS DESCRIPTION
Max No. of Indoor Units 50 units/50 groups Operation

PAC-SF44SRA
50 units/50 groups Display

ON/OFF MODE SELECTION

Run and Stop operation Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems Sets the groups temperature control. Cool/Dry: 19-30C Heat: 17-28C Auto: 19-28C 4 speed - Lo-Mi1-Mi2-Hi 2 speed - Lo-Hi Air Flow angles: 100-80-60-40 and auto swing Run/Stop, Temperature Setting, Mode Selection and Filter Reset functions can be prohibited

TEMPERATURE SETTING

FAN SPEED SETTINGS AIR FLOW DIRECTION PERMIT/PROHIBIT FUNCTION INDOOR RETURN AIR TEMPERATURE ERROR INDICATION VENTILATION INTERLOCK EXTERNAL INPUT EXTERNAL OUTPUT COMPATIBILITY DIMENSIONS - mm (WxDxH)

Measures the intake temperature of the master unit within the group Displays a 4 digit code and the affected unit address Allows the group to be interlocked with a heat recovery Lossnay unit Hardwired connections available Hardwired connections available Compatible with: On/Off or Fire Alarm Run/Faults City Multi or Mr Slim via PAC-SF80MA or M Series via MAC-399IF 130x19x120

NOTE: When the remote On/Off hardwired input is used, the On/Off remote controller buttons will be deactivated (centrally controlled).

Page 226

Interfaces
A range of newly created interfaces are now available for use when connecting to third party controllers.

TCB1

DIDO

TCB1

DIDO

Technical Information
Interfaces
FUNCTION DESCRIPTION TCB1
Control Monitor

DIDO
Control Monitor

MS-FRT -TCB-TEMP
Control Monitor

ON/OFF BUT CENTRALLY CONTROLLED ON/OFF BUT NOT CENTRALLY CONTROLLED TEMPERATURE SETTINGS

ON/OFF control. Remote controller ON/OFF button deactivated

ON/OFF control. Remote controller ON/OFF button activated

(analogue 0 to 10VDC)

ERROR INDICATION HEATING INTERLOCKING


A supplied remote sensor is installed on the wet system radiator to prevent the air conditioning running while heating Interface compatible with: Mr Slim City Multi 80x45x80 Mr Slim City Multi 130x19x120 Mr Slim

COMPATIBILITY

DIMENSIONS - mm (WxDxH)

130x19x120

Page 227

System Controller / Interfaces

Sets the groups temperature control. Cool/Dry: 19-30C Heat: 17-28C Auto: 19-28C

Controls Range 2008

G50 Controller
Centralised Controller with WebServer Capabilities
The G50 centralised controller was the first of its kind in the industry to utilise Ethernet Technology. By using Internet Explorer as its local or remote software, the G50 gives you instant access to all your control functions from the comfort of your own PC. The G50 can control up to 50 indoor units and can take the place of local remote controllers, offering the same level of monitoring and control. The G50 has many functions as standard but can also have further features activated via Pin Codes.
M-NET

G50

ETHERNET

PAC-SC50KUA

Viewed using Microsoft Internet Explorer

Technical Information
G50 Controller
FUNCTION OPERATION PLATFORM MAX No. OF INDOOR UNITS ON/OFF MODE SELECTION TEMPERATURE SETTING FAN SPEED SETTING AIR FLOW DIRECTION TIMER OPERATION PERMIT/PROHIBIT FUNCTION INDOOR RETURN AIR TEMPERATURE ERROR INDICATION TEST RUN FUNCTION VENTILATION INTERLOCK WEB SETPOINT LIMIT WEB AUTO CHANGEOVER WEB INITIAL SETTING WEB LOGIN EXTERNAL INPUT/OUTPUT POWER SUPPLY PACK COMPATIBILITY DIMENSIONS - mm (WxDxH) DESCRIPTION Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista Up to 50 indoor units can be connected Run and Stop operation for a single group Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems Sets the groups temperature control. Cool/Dry: 19-30C, Heat:17-28C, Auto: 19-28C 4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi Air Flow angles:100-80-60-40 and auto swing Weekly. Maximum of 3 time sequences with 3 Start/Stop times per day for all groups can be allocated Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting, Mode Selection and Filter Reset) can be activated Displays the measured intake temperature from each group Displays a 4 digit code and the affected unit address. An error log is held showing the last 64 date stamped alarms Allows each unit within the group to operate in test mode Allows the group to be interlocked with a heat recovery Lossnay unit Reduce the setpoint band of each individual unit (e.g. 23C to 25C) Automatically switch heat pump outdoor unit to cooling or heating mode depending on the requirements Commission the G50 from the web pages Administrator able to allow specific function access to guest Hardwired connections are available for : PAC-SC50KUA City Multi or Mr Slim via PAC-SF80MA or M Series via MAC-399IF 300x79x120 Inputs: Level Signal-Batch Start/Stop, Batch Emergency Stop Outputs: Start/Stop Status, Error/Normal Status

G50 Software Options - Pin Code Activation


G50 G50 G50 G50 - Web Monitor - Email - AS - EC Control and Monitor the G50 via Internet Explorer Enable E-mail activation on fault conditions Weekly / Annual Scheduling and Night Set Back Energy Charge G50 - ES G50 - PC G50 - VRC Energy Saving Capability Peak Cut Control Virtual Remote Controllers

Page 228

AG150 Controller

NEW in September 2008

Touch Screen Centralised Controller with WebServer Capabilities


The new AG150 Mitsubishi Electric centralised controller offers a large 9 inch touch screen display with easy control of up to 50 indoor units. The AG150 can calculate the energy used for each system, zone or indoor unit. The refrigerant status check function can be activated regularly (in conjuction with the new YHM-A City Multi range) and an Internet connection with SSL security is also available to monitor and control the AG150 remotely and receive Email under fault conditions.
M-NET

AG150 ETHERNET
PAC-SC51KUA

Viewed using Microsoft Internet Explorer

Technical Information

AG150 Controller
FUNCTION TOUCH SCREEN OPERATION PLATFORM MAX No. OF INDOOR UNITS ON/OFF MODE SELECTION TEMPERATURE SETTING FAN SPEED SETTING AIR FLOW DIRECTION TIMER OPERATION PERMIT/PROHIBIT FUNCTION INDOOR RETURN AIR TEMPERATURE ERROR INDICATION TEST RUN FUNCTION VENTILATION INTERLOCK WEB SETPOINT LIMIT WEB AUTO CHANGEOVER WEB INITIAL SETTING WEB LOGIN WEB REFRIGERANT STATUS CHECK ENERGY CHARGING ENERGY SAVE CONTROL LOAD SHEDDING EXTERNAL INPUT/OUTPUT POWER SUPPLY PACK COMPATIBILITY DIMENSIONS - mm (WxDxH) DESCRIPTION Wide high resolution 9 touch screen Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista Up to 50 indoor units can be connected Run and Stop operation for a single group Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems Sets the groups temperature control. Cool/Dry: 19-30C, Heat:17-28C, Auto: 19-28C 4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi Air Flow angles:100-80-60-40 and auto swing Annual or weekly. Night set back option available allowing the setpoint to be set to 12C Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting, Mode Selection and Filter Reset) can be activated Displays the measured intake temperature from each group Displays a 4 digit code and the affected unit address. An error log is held showing the last 64 date stamped alarms Allows each unit within the group to operate in test mode Allows the group to be interlocked with a heat recovery Lossnay unit Reduce the setpoint band of each individual unit (e.g. 23C to 25C) Automatically switch heat pump outdoor unit to cooling or heating mode depending on the requirements Commission the G50 from the web pages Administrator able to allow specific function access to guest Activate refrigerant volume checking function on Modular City Multi systems Able to create bills for individual indoor units, groups of indoor units or a complete system (Optional) via the PAC-YG60MCA Individual indoor unit, group of indoor units or a complete system can be controlled. There are various energy saving options available (Optional) Activate energy saving mode when energy consumption is too high Hardwired connections are available for : PAC-SC51KUA City Multi or Mr Slim via PAC-SF80MA or M Series via MAC-399IF 300x62x175 Inputs: Level Signal-Batch Start/Stop, Batch Emergency Stop Outputs: Start/Stop Status, Error/Normal Status

AG150 Software Options - Pin Code Activation


AG150 - Basic AG150 - Energy AG150 - VRC Web monitoring, Email, Annual scheduling Energy monitoring, energy saving, load shedding Virtual remote controllers

Page 229

G50 Controller / AG150 Controller

Controls Range 2008

GB50 Controller
Centralised Controller with WebServer Capabilities
The GB50 has been developed to access all your control functions from the comfort of your own PC, without the need for a controller keypad or LCD display and at a very competitive price.

M-NET

GB50

ETHERNET

PAC-SC50KUA

Viewed using Microsoft Internet Explorer

Technical Information
GB50 Controller
FUNCTION OPERATION PLATFORM MAX No. OF INDOOR UNITS ON/OFF MODE SELECTION TEMPERATURE SETTING FAN SPEED SETTING AIR FLOW DIRECTION TIMER OPERATION PERMIT/PROHIBIT FUNCTION INDOOR RETURN AIR TEMPERATURE ERROR INDICATION TEST RUN FUNCTION VENTILATION INTERLOCK WEB SETPOINT LIMIT WEB AUTO CHANGEOVER WEB INITIAL SETTING WEB LOGIN EXTERNAL INPUT/OUTPUT POWER SUPPLY PACK COMPATIBILITY DIMENSIONS - mm (WxDxH) DESCRIPTION Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista Up to 50 indoor units can be connected Run and Stop operation for a single group Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems Sets the groups temperature control. Cool/Dry: 19-30C, Heat:17-28C, Auto: 19-28C 4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi Air Flow angles:100-80-60-40 and auto swing Annual or weekly. Night set back option available allowing the setpoint to be set down to 12C Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting, Mode Selection and Filter Reset) can be activated Displays the measured intake temperature from each group Displays a 4 digit code and the affected unit address. An error log is held showing the last 64 date stamped alarms Allows each unit within the group to operate in test mode Allows the group to be interlocked with a heat recovery Lossnay unit Reduce the setpoint band of each individual unit (e.g. 23C to 25C) Automatically switch heat pump outdoor unit to cooling or heating mode depending on the requirements Commission the GB50 from the web pages Administrator able to allow specific function access to guest Hardwired connections are available for : PAC-SC50KUA City Multi or Mr Slim via PAC-SF80MA or M Series via MAC-399IF 250x38x130 Inputs: Level Signal-Batch Start/Stop, Batch Emergency Stop Outputs: Start/Stop Status, Error/Normal Status

GB50 Software Options - Pin Code Activation


G50 G50 G50 G50 - EC - ES - PC - VRC Energy Charge Energy Saving Capability Peak Cut Control Virtual Remote Controllers

Page 230

G50/AG150/GB50 Controller Web Screenshots


Login Monitor Air Conditioning - Overview

Access to the web pages is secured using a customised username and password.

The first screen allows you to monitor all the units connected to the G50/AG150/GB50. Each icon displays On/Off, Faults and timer On/Off.

Monitor Air Conditioning - Block view

Remote Controller Settings

Each area of the building can be displayed with information about On/Off, Setpoint, Mode and Temperature.

Daily, Weekly and Annual Scheduling (AS PIN code)

Click on any icons in the Monitor View page to access the remote controller. Lossnay units can also be controlled. Buttons on the local controllers may be locked (On/Off, Mode, Setpoint, Filter Reset).

Monitor Fault Codes

Multiple Users (VRC PIN code)

Multiple Users (VRC PIN code)

If the G50/AG150/GB50 is connected to an office LAN, the staff will then be able to access the web pages. With VRC each member of staff will have their own username and password.

Installation costs will be reduced as no wall remote controllers will need to be purchased and installed.

New icons now available to suit model type installed

Page 231

GB50 Controller / G50/AG150/GB50 Web Screenshots

Scheduling may be set from the web pages. A night set back operation is available (Heat, 12C). Optional on the G50, standard on the AG150/GB50.

Faults with the unit address can be displayed under fault conditions. Email status can also be shown.

Controls Range 2008

G50/AG150/GB50 Desktop Remote Controller


More and more customers are using the G50/GB50 controller directly from their computers, so Mitsubishi Electric has launched a new, even simpler alternative which presents the customer with what looks like a standard remote controller interface - on their PC desktop. Called the PAR-21PC, the new application can also be minimised in the Desktop Toolbar, just like other Windows applications, so that the customer can have immediate control with just one click of the mouse.

M-NET

*NOTE 1

ETHERNET

PAC-SC50KUA

Technical Information
PAR-21PC Desktop Remote Controller
FUNCTION OPERATION PLATFORM MAX No. OF INDOOR UNITS ON/OFF MODE SELECTION TEMPERATURE SETTING FAN SPEED SETTING AIR FLOW DIRECTION CLOCK DISPLAY INDOOR RETURN AIR TEMPERATURE ERROR INDICATION TIMER OPERATION DESCRIPTION Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4or Windows Professional XP service pack 2 or Windows Vista Up to 16 indoor units within a group Run and Stop operation for a single group Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems Sets the groups temperature control. Cool/Dry: 19-30C, Heat:17-28C, Auto: 19-28C 4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi Air Flow angles:100-80-60-40 and auto swing Displays the time on the desktop controller Displays the measured intake temperature from each group Displays a 4 digit code and the affected unit address. Weekly. Maximum of 3 time sequences with 3 Start/Stop times per day for all groups can be allocated

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA

Page 232

G50/AG150/GB50 Third Party Equipment Interfaces


The new third party equipment interfaces allow the user to monitor and control third party equipment from the G50/GB50 web pages.
ETHERNET

*NOTE 1

PAC-YG66DCA

PAC-YG63MCA

EQUIPMENT 1

EQUIPMENT 2

SENSOR 1

SENSOR 2

Technical Information
Third Party Interfaces
FUNCTION MAX No. OF INPUTS MAX No. OF OUTPUTS MAX No. OF EQUIPMENT POWER SUPPLY MONITOR CONTROL SIGNAL DIMENSIONS - mm (WxDxH) DESCRIPTION
Power supply required From G50/GB50 web pages or TG2000 From G50/GB50 web pages or TG2000 Signal required to monitor and control equipment -

PAC-YG66DCA
2 x Digital 2 x Digital 2 24VDC Run / Faults On/Off Volt free contact 200x45x120

PAC-YG63MCA
2 x Analogue 24VDC Temperature / Humidity Temperature 4-20mA / 1-5V / 0-10V / Pt100 Humidity 4-20mA / 1-5V / 0-10V 200x45x120

General Equipment

Temperature / Humidity

Third party equipment can be monitored and controlled from the web pages.

Temperature and humidity can be monitored.

Trend Logging

Temperature / Humidity Limit

Temperature and humidity can be recorded and displayed.

Limit (high and low) can be set to trigger alarms via email.

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA NOTE 2: Temperature Sensors and Humidity Sensors not supplied by MEUK

Page 233

G50/AG150/GB50 Desktop Remote Controller / G50/AG150/GB50 Third Party Equipment Interfaces

Controls Range 2008

G50/AG150/GB50 Programmable Logic Controller


The PLC controller allows a hotel (for example) to have more accurate control over its air conditioning. The PLC works in conjunction with the key card system installed in each bedroom in many hotels. When the room is occupied, the PLC will switch ON the unit and reset the air conditioning to predetermined settings (for instance AUTO, 21C). When the room is unoccupied, the PLC will monitor the temperature in the room. If the temperature is too low or too high, the PLC will restart the unit.

M-NET

*NOTE 1

ETHERNET

PAC-SC50KUA Ving Card Ving Card Ving Card

PLC

Technical Information
PLC-QSERIES-LSPD
FUNCTION MAX No. OF INDOOR UNITS ON/OFF MODE SELECTION TEMPERATURE SETTING PERMIT/PROHIBIT SETTING OCCUPIED ROOM SETTING UNOCCUPIED ROOM SETTING DESCRIPTION Up to 200 indoor units Run and Stop operation for a single group Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems Sets the groups temperature control. Cool/Dry: 19-30C, Heat:17-28C, Auto: 19-28C Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting, Mode Selection and Filter Reset) can be activated ON, AUTO, 21C (Factory setting)

If the temperature is below 16C the PLC restarts the unit to ON, HEAT, 19C and stops the unit when the temperature has reached 18C (Factory setting) COMPATIBILITY DIMENSIONS - mm (WxDxH) City Multi only 198x44x98

If the temperature is above 26C the PLC restarts the unit to ON, COOL, 21C and stops the unit when the temperature has reached 24C (Factory setting)

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA NOTE 2: It may take up to 3 minutes to switch ON the indoor unit (this time depends on how many indoor units are connected to the PLC).

Page 234

TG2000 Software
PC Based Software Package
The TG2000 centralised PC based graphical software package allows the operator to control and monitor up to a maximum of 2000 indoor units. This software has been designed to connect directly to an air conditioning system via the G50/GB50 controller, allowing the operator the required functionality to control and monitor the complete air conditioning system from a central location.

M-NET

*NOTE 1

ETHERNET

PAC-SC50KUA

Technical Information
TG2000 PC Based software that works in conjunction with G50/GB50 Controller
FUNCTION OPERATING PLATFORM MAX No. OF INDOOR UNITS OPERATIONAL SECTIONS DESCRIPTION

2000 Indoor units, 50 indoor units per G50/AG150/GB50 The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation, monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration Indicates the On/Off status of each group within the selected graphical screen or entire building Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode Displays the current fan speed setting for each group on the selected graphical screen Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code Displays the return air temperature of the master indoor unit within a group On/Off schedules can be set for each group, each graphical screen or the entire building Individual indoor unit, group of indoor units or a complete system can be controlled. There are various energy saving options available (Optional) Able to log: Return air temperature, setpoint, mode, On/Off, power consumption by group or by indoor unit, watt-hour meter and then email to customer The complete system configurations can be allocated between multiple screens. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history

ON/OFF OPERATION MODE SET TEMPERATURE AIR SPEED REMOTE CONTROLLER PROHIBIT/PERMIT ABNORMALITY (FAULT) MONITORING

ROOM TEMPERATURE MONITORING SCHEDULED ON/OFF ENERGY SAVE CONTROL TREND LOGGING GRAPHICAL SCREENS EMAIL

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA

Page 235

G50/AG150/GB50 Programmable Logic Controller / TG2000 Software

Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista

Controls Range 2008

TG2000 Software with Energy Monitoring


PC Based Software Package
The TG2000 centralised PC based graphical software package allows the operator to control and monitor up to a maximum of 2000 indoor units. This software has been designed to connect directly to an air conditioning system via G50/GB50 controller, allowing the operator all the required functionality to control and monitor the complete air conditioning system from a central location. In addition to providing a centralised control facility, the TG2000 allows complete energy consumption data to be logged with user definable billing groups and electrical tariffs for billing purposes.

M-NET

*NOTE 1

ETHERNET
PAC-SC50KUA

PAC-YG60MCA

METER 1

METER 2

METER 3

METER 4

Technical Information
TG2000 Software with Energy Monitoring
FUNCTION OPERATING PLATFORM MAX No. OF INDOOR UNITS OPERATIONAL SECTIONS DESCRIPTION Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4or Windows Professional XP service pack 2 or Windows Vista 2000 Indoor units, 50 indoor units per G50/AG150/GB50 The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation, monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration Indicates the On/Off status of each group within the selected graphical screen or entire building Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode Displays the current fan speed setting for each group on the selected graphical screen Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code Displays the return air temperature of the master indoor unit within a group On/Off schedules can be set for each group, each graphical screen or the entire building Able to create or email bills for individual indoor units, groups of indoor units or a complete system (Optional) via the PAC-YG60MCA Activate refrigerant volume checking function on Modular City Multi systems Able to create bills for individual indoor units, groups of indoor units or a complete system (Optional) via the PAC-YG60MCA Individual indoor unit, group of indoor units or a complete system can be controlled. There are various energy saving options available (Optional) Activate energy saving mode when energy consumption is too high Able to log: Return air temperature, setpoint, mode, On/Off, power consumption by group or by indoor unit, watt-hour meter and then email to customer The complete system configurations can be allocated between multiple screens. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history

ON/OFF OPERATION MODE SET TEMPERATURE AIR SPEED REMOTE CONTROLLER PROHIBIT/PERMIT ABNORMALITY (FAULT) MONITORING

ROOM TEMPERATURE MONITORING SCHEDULED ON/OFF ENERGY CHARGING WEB REFRIGERANT STATUS CHECK ENERGY CHARGING ENERGY SAVE CONTROL LOAD SHEDDING TREND LOGGING GRAPHICAL SCREENS EMAIL

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA NOTE 2: Energy Meters not supplied by MEUK

Page 236

TG2000 Software with Third Party Equipment


PC Based Software Package
The TG2000 centralised PC based graphical software package allows the operator to control and monitor up to a maximum of 2000 indoor units. This software has been designed to connect directly to an air conditioning system via G50/GB50 controller, allowing the operator all the required functionality to control and monitor the complete air conditioning system from a central location. In addition to providing a centralised control facility, the TG2000 allows you to monitor and control third party equipment.
M-NET

*NOTE 1

ETHERNET
PAC-SC50KUA PAC-YG66DCA PAC-YG63MCA

EQUIPMENT 1

EQUIPMENT 2

SENSOR 1

SENSOR 2

Technical Information
TG2000 Software with Third Party Equipment
FUNCTION OPERATING PLATFORM MAX No. OF INDOOR UNITS OPERATIONAL SECTIONS DESCRIPTION Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4or Windows Professional XP service pack 2 or Windows Vista 2000 Indoor units, 50 indoor units per G50/AG150/GB50

ON/OFF OPERATION MODE SET TEMPERATURE AIR SPEED REMOTE CONTROLLER PROHIBIT/PERMIT ABNORMALITY (FAULT) MONITORING

Indicates the On/Off status of each group within the selected graphical screen or entire building Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode Displays the current fan speed setting for each group on the selected graphical screen Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code Displays the return air temperature of the master indoor unit within a group On/Off schedules can be set for each group, each graphical screen or the entire building Individual indoor unit, group of indoor units or a complete system can be controlled. There are various energy saving options available (Optional) Able to log: Return air temperature, setpoint, mode, On/Off, power consumption by group or by indoor unit, watt-hour meter and then email to customer The complete system configurations can be allocated between multiple screens. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located Monitor general equipment Run and Faults via the PAC-YG66DCA interface and Temperature and Humidity via the PAC-YG63MCA Control general equipment On/Off via the PAC-YG66DCA The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history

ROOM TEMPERATURE MONITORING SCHEDULED ON/OFF ENERGY SAVE CONTROL TREND LOGGING GRAPHICAL SCREENS THIRD PARTY EQUIPMENT MONITOR THIRD PARTY EQUIPMENT CONTROL EMAIL

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA NOTE 2: Temperature and Humidity Sensors not supplied by MEUK

Page 237

TG2000 Software with Energy Monitoring / TG2000 Software with Third Party Equipment

The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation, monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration

Controls Range 2008

TG2000 WAN

(Wide Area Network)

Software

PC Based Software Package used to monitor and control multiple sites


The TG2000 WAN centralised PC based graphical software package allows the operator to control and monitor up to a maximum of 1000 sites. Utilising the companies Wide Area Network, the complete (geographically distributed) air conditioning asset base can be controlled and monitored from a centralised location.

PAC-YG66DCA

PAC-YG63MCA

WAN

SITE 1 (i.e. MANCHESTER) *NOTE 1

EQUIPMENT 1

EQUIPMENT 2

SENSOR 1

SENSOR 2

PAC-YG66DCA

PAC-YG63MCA

SITE 999 (i.e. BIRMINGHAM) *NOTE 1

EQUIPMENT 1

EQUIPMENT 2

SENSOR 1

SENSOR 2

Technical Information
TG2000WAN (Wide Area Network) Software
FUNCTION OPERATING PLATFORM MAX No. OF SITES MAX No. OF INDOOR UNITS PER SITE OPERATIONAL SECTIONS DESCRIPTION Pentium III, CPU 1000 Mhz, 256 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista 1000 2000 Indoor units, 50 indoor units per G50/AG150/GB50 (per site) The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation, monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration Indicates the On/Off status of each group within the selected graphical screen or entire building Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode Displays the current fan speed setting for each group on the selected graphical screen Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code Displays the return air temperature of the master indoor unit within a group On/Off schedules can be set for each group, each graphical screen or the entire building The complete system configurations can be allocated between multiple screens. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located Monitor general equipment Run and Faults via the PAC-YG66DCA interface and Temperature and Humidity via the PAC-YG63MCA Control general equipment On/Off via the PAC-YG66DCA The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history

ON/OFF OPERATION MODE SET TEMPERATURE AIR SPEED REMOTE CONTROLLER PROHIBIT/PERMIT ABNORMALITY (FAULT) MONITORING

ROOM TEMPERATURE MONITORING SCHEDULED ON/OFF GRAPHICAL SCREENS THIRD PARTY EQUIPMENT MONITORING THIRD PARTY EQUIPMENT CONTROL EMAIL

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA NOTE 2: The TG2000 WAN cannot be utilised if the following site functions are required: energy charging, energy saving and trend logging. NOTE 3: Temperature and Humidity Sensors not supplied by MEUK

Page 238

TG2000
Display Whole

Screenshots
Display Block

The 2000 indoor units status may be shown on one screen.

Block may be set for each area. Settings may be changed by one click of the mouse for each area.

Display Floor

Remote Controller Settings

AutoCAD drawing may be imported to TG2000 to display floor screens.

Click on any icons in the floor view to access the remote controller settings. Buttons on the local controllers may be locked (On/Off, Mode, Setpoint, Filter reset).

Daily, Weekly and Annual Scheduling (AS PIN code)

Monitor Fault Codes

Energy Monitoring (EC PIN code)

Energy Saving (ES PIN code)

TG2000 in conjunction with energy meters can monitor the energy consumption for each outdoor unit, indoor unit or area. The indoor unit run hours can also be displayed.

TG2000 offers different energy saving options including load shedding.

New icons now available to suit model type installed

Page 239

TG2000 WAN / TG2000 Screenshots

Scheduling may be set from the TG2000. A night set back operation is available (HEAT, 12C). Optional on the G50, standard with the GB50.

Faults with the unit address can be displayed under fault conditions.

Controls Range 2008

BEMS BACnet Interface

Procon BAC-IP/50
TM

To further enhance our complete open system network offering, we offer a BACnet gateway solution. Utilising the ASHRAE BACnet standard, complete control and monitoring integration can be achieved with up to 50 air conditioning units.

M-NET

*NOTE 1

ETHERNET

PAC-SC50KUA

BAC-IP/50

Technical Information
BACnet INTERFACE

FUNCTION MAX No. OF INDOOR UNITS COMPATIBILITY DIMENSIONS - mm (WxDxH)

BAC-IP/50 50 City Multi Mr Slim via PAC-SF80MA M Series via MAC-399IF 144x34x104

COMPATIBLE WITH Andover Controls York BMS Siemens Priva Building Intelligence Delta Controls

BACnet INTERFACE

FUNCTION

NETWORK VARIABLE
On/Off Mode Operation Setpoint Adjustment Fan Speed Control Permit / Prohibit Airflow Direction Filter Sign

NOTES
Run/Stop Cool / Dry / Heat / Auto / Fan Cooling 19-30C, Heating 17-28C, Auto 19-28C Lo-Mi1-Mi2-Hi On/Off, Mode, Setpoint Horizontal - 60,80,100 swing Normal/Reset

Control

Monitor
On/Off Mode Operation Setpoint Adjustment Fan Speed Control Permit / Prohibit Airflow Direction Fault Code Filter Sign Room Temperature Run/Stop Cool / Dry / Heat / Auto / Fan Cooling 19-30C, Heating 17-28C, Auto 19-28C Lo-Mi1-Mi2-Hi On/Off, Mode, Setpoint Horizontal - 60,80,100 swing 4 Character code - Indicates all unit alarms -

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA

Page 240

BEMS BACnet Mr Slim Interface

Procon BAC-A/50
TM

A new BACnet Interface has been specially developed for the Mr Slim systems. The BAC-A/50 can control up to 50 individual systems.

PAC-SK81SI

BAC-A/50

Technical Information
BACnet MR SLIM INTERFACE

FUNCTION

BAC-A/50

COMPATIBLE WITH Andover Controls York BMS

MAX No. OF 50 OUTDOOR UNITS COMPATIBILITY DIMENSIONS - mm (WxDxH)

Mr Slim via PAC-SK81SI

Siemens Priva Building Intelligence

270x75x210

Delta Controls

FUNCTION

NETWORK VARIABLE
On/Off Mode Operation Setpoint Adjustment Fan Speed Control Permit / Prohibit Airflow Direction Filter Sign

NOTES
Run/Stop Cool / Dry / Heat / Auto / Fan Cooling 19-30C, Heating 17-28C, Auto 19-28C Lo-Mi1-Mi2-Hi On/Off, Mode, Setpoint Horizontal - 60,80,100 swing Normal/Reset

Control

Monitor
On/Off Mode Operation Setpoint Adjustment Fan Speed Control Permit / Prohibit Airflow Direction Fault Code Filter Sign Room Temperature Run/Stop Cool / Dry / Heat / Auto / Fan Cooling 19-30C, Heating 17-28C, Auto 19-28C Lo-Mi1-Mi2-Hi On/Off, Mode, Setpoint Horizontal - 60,80,100 swing 4 Character code - Indicates all unit alarms -

Page 241

BEMS BACnet Interface / BEMS BACnet Mr Slim Interface

BACnet MR SLIM INTERFACE

Controls Range 2008

BEMS LonWorks Interface

LMAP
The Mitsubishi Electric LMAP continues to strengthen the ability of our products to interface with other third party building control systems using the globally recognised and accepted open network protocol Echelon LonWorks . LonWorks was introduced into the building services industry a number of years ago with the aim of establishing itself as the defacto communications standard. Many hundreds of products now exist that utilise the LonWorks protocol from complete systems like BEMS, lighting, power monitoring and security down to simple sensors and relay switches.

To ensure that our products can connect directly and easily with other LonWorks products, the L-MAP02 was designed utilising Echelon MIPS technology and was the first to provide data in the LonWorks SNVT (Standard Network Variable Type) format.

M-NET

LMAP

Technical Information
LMAP LonWorks INTERFACE
FUNCTION MAX No. OF INDOOR UNITS COMPATIBILITY DIMENSIONS - mm (WxDxH) LMAP 50 (G50/AG150/GB50 optional) City Multi Mr Slim via PAC-SF80MA M Series via MAC-399IF 340x60x360 COMPATIBLE WITH Honeywell Johnson Controls Realtime Control Systems Smart Controls (LTX51/LTX21 via VCI)

LMAP LonWorks INTERFACE


FUNCTION NETWORK VARIABLE
On/Off Mode Operation Setpoint Adjustment Fan Speed Control Permit / Prohibit Filter Sign

NOTES
Run/Stop Cool / Dry / Heat / Auto / Fan Cooling 19-30C, Heating 17-28C, Auto 19-28C Lo-Mi1-Mi2-Hi On/Off, Mode, Setpoint (only available when using PAC-YT51CRA or PAR-21MAA) Normal/Reset

Control

Monitor
On/Off Mode Operation Setpoint Adjustment Fan Speed Control Permit / Prohibit Fault Code Filter Sign Room Temperature Run/Stop Cool / Dry / Heat / Auto / Fan Cooling 19-30C, Heating 17-28C, Auto 19-28C Lo-Mi1-Mi2-Hi On/Off, Mode, Setpoint (only available when using PAC-YT51CRA or PAR-21MAA) 4 Character code - Indicates all unit alarms -

Page 242

BEMS Modbus Interfaces


Procon IP-32M / IP-50M / IP-100M
TM

To further compliment the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the Modbus range has been developed to accommodate the typical end-user needs as experienced within the UK market.

M-NET

*NOTE 1

ETHERNET

PAC-SC50KUA

Modbus
IP-32M IP-50M IP-100M

Technical Information
MODBUS INTERFACES
FUNCTION MAX No. OF INDOOR UNITS COMPATIBILITY DIMENSIONS - mm (WxDxH) IP-32M 32 City Multi Mr Slim via PAC-SF80MA M Series via MAC-399IF 270x75x210 IP-50M 50 City Multi Mr Slim via PAC-SF80MA M Series via MAC-399IF 270x75x210 IP-100M 100 City Multi Mr Slim via PAC-SF80MA M Series via MAC-399IF 270x75x210 COMPATIBLE WITH Trend via Synapsys SXNC200 Cylon Satchwell Crestron (Home automation) Invensys Interactive Homes North BT Andover Siemens

MODBUS INTERFACE UNITS - OPERATIONAL INFORMATION


Control
On/Off Mode Operation Setpoint Adjustment Run/Stop Cool / Dry / Heat / Auto / Fan Cooling 19-30C Heating 17-28C Auto 19-28C Fan Speed Control Lo-Mi1-Mi2-Hi

Monitor
On/Off Mode Operation Setpoint Adjustment Run/Stop Cool / Dry / Heat / Auto / Fan Cooling 19-30C Heating 17-28C Auto 19-28C Fan Speed Control Fault Code Room Temperature Lo-Mi1-Mi2-Hi 4 Character code Indicates all unit alarms -

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA

Page 243

BEMS LonWorks Interface / BEMS Modbus Interfaces

FUNCTION

NETWORK VARIABLE

MODBUS

Controls Range 2008

BEMS Modbus Mr Slim Interface


Procon A32M
TM

To further compliment the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the Modbus range has been developed to accommodate the typical end-user needs as experienced within the UK market.

PAC-SK81SI

Modbus
A32M

Technical Information
MODBUS MR SLIM INTERFACE
FUNCTION A32M COMPATIBLE WITH Trend via Synapsys SXNC200 Cylon Satchwell Crestron (Home automation) Invensys Interactive Homes North BT Andover Siemens MAX No. OF 32 OUTDOOR UNITS COMPATIBILITY DIMENSIONS - mm (WxDxH) Mr Slim via PAC-SK81SI

270x75x210

MODBUS MR SLIM INTERFACE - OPERATIONAL INFORMATION


FUNCTION NETWORK VARIABLE
On/Off Mode Operation Setpoint Adjustment

MODBUS
Run/Stop Cool / Dry / Heat / Auto / Fan Cooling 19-30C Heating 17-28C Auto 19-28C

Control

Fan Speed Control

Lo-Mi1-Mi2-Hi

Monitor
On/Off Mode Operation Setpoint Adjustment Run/Stop Cool / Dry / Heat / Auto / Fan Cooling 19-30C Heating 17-28C Auto 19-28C Fan Speed Control Fault Code Room Temperature Lo-Mi1-Mi2-Hi 4 Character code Indicates all unit alarms -

NOTE: Not available on SEZ / SLZ

Page 244

BEMS Modbus Splits Interface


Procon A1M
TM

To further compliment the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the Modbus range has been developed to accommodate the typical end-user needs as experienced within the UK market.

A1M

Modbus

Technical Information
MODBUS SPLITS INTERFACE
FUNCTION MAX No. OF INDOOR UNITS COMPATIBILITY DIMENSIONS - mm (WxDxH) 1 M Series Mr Slim 72x27x50 A1M COMPATIBLE WITH Trend via Synapsys SXNC200 Cylon Satchwell Crestron (Home automation) Invensys Interactive Homes North BT Andover Siemens

MODBUS SPLITS INTERFACE - OPERATIONAL INFORMATION


FUNCTION NETWORK VARIABLE
On/Off Mode Operation Setpoint Adjustment

MODBUS
Run/Stop Cool / Dry / Heat / Auto / Fan Cooling 19-30C Heating 17-28C Auto 19-28C

Control

Fan Speed Control

Lo-Mi1-Mi2-Hi

Monitor
On/Off Mode Operation Setpoint Adjustment Run/Stop Cool / Dry / Heat / Auto / Fan Cooling 19-30C Heating 17-28C Auto 19-28C Fan Speed Control Fault Code Room Temperature Lo-Mi1-Mi2-Hi 4 Character code Indicates all unit alarms -

Page 245

BEMS Modbus Mr Slim Interface / BEMS Modbus Splits Interface

Controls Range 2008

BEMS KNX-EIB Interfaces


Procon KNX-EIB-IP-15/100
TM

To further compliment the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the KNX-EIB range has been developed to accommodate the typical end-user needs as experienced within the UK market.

M-NET

*NOTE 1

ETHERNET

PAC-SC50KUA

KNX-EIB
KNX-EIB-IP-15 KNX-EIB-IP-100

Technical Information
KNX-EIB CITY MULTI INTERFACES
FUNCTION MAX No. OF INDOOR UNITS COMPATIBILITY DIMENSIONS - mm (WxDxH) KNX-EIB-IP-15 15 City Multi Mr Slim via PAC-SF80MA M Series via MAC-399IF 107x58x105 KNX-EIB-IP-100 100 City Multi Mr Slim via PAC-SF80MA M Series via MAC-399IF 107x58x105 COMPATIBLE WITH ABB Intelligent Buildings Nova Controls Ltd Siemens

KNX-EIB CITY MULTI INTERFACE UNITS - OPERATIONAL INFORMATION


FUNCTION NETWORK VARIABLE
On/Off Mode Operation Setpoint Adjustment

MODBUS
Run/Stop Cool / Dry / Heat / Auto / Fan Cooling 19-30C Heating 17-28C Auto 19-28C

Control

Fan Speed Control

Lo-Mi1-Mi2-Hi

Monitor
On/Off Mode Operation Setpoint Adjustment Run/Stop Cool / Dry / Heat / Auto / Fan Cooling 19-30C Heating 17-28C Auto 19-28C Fan Speed Control Fault Code Room Temperature Lo-Mi1-Mi2-Hi 4 Character code Indicates all unit alarms -

*NOTE 1: Applicable with G50 / PAC-SC50KUA or AG150 / PAC-SC51KUA or GB50 / PAC-SC50KUA

Page 246

BEMS KNX-EIB Splits Interface


Procon KNX-EIB-A-1
TM

To further compliment the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the KNX-EIB range has been developed to accommodate the typical end-user needs as experienced within the UK market.

KNX-EIB-A-1

KNX-EIB

Technical Information
KNX-EIB SPLITS INTERFACE
FUNCTION MAX No. OF INDOOR UNITS COMPATIBILITY DIMENSIONS - mm (WxDxH) 1 M Series Mr Slim 60x25x48 KNX-EIB-A-1 COMPATIBLE WITH ABB Intelligent Buildings Nova Controls Ltd Siemens

FUNCTION

NETWORK VARIABLE
On/Off Mode Operation Setpoint Adjustment

MODBUS
Run/Stop Cool / Dry / Heat / Auto / Fan Cooling 19-30C Heating 17-28C Auto 19-28C

Control

Fan Speed Control

Lo-Mi1-Mi2-Hi

Monitor
On/Off Mode Operation Setpoint Adjustment Run/Stop Cool / Dry / Heat / Auto / Fan Cooling 19-30C Heating 17-28C Auto 19-28C Fan Speed Control Fault Code Room Temperature Lo-Mi1-Mi2-Hi 4 Character code Indicates all unit alarms -

Page 247

BEMS KNX-EIB Interfaces / BEMS KNX-EIB Splits Interface

KNX-EIB SPLITS INTERFACE - OPERATIONAL INFORMATION

Controls Range 2008

M2M - Machine 2 Machine Interface


Procon Maxi M2M-IP/50
TM

To offer remote management of its air conditioning units to companies with large numbers of dispersed offices, Mitsubishi Electric has adopted the M2M platform. The machine-to-machine (M2M) technology platform allows customers to integrate multiple sites into one network. The air conditioning units as well as third party equipment will be wirelessly connected to the M2M server and use the GPRS network to communicate.
Maxi M2M-IP/50
GB50

MEUK
METER 1 METER 2 METER 3 METER 4 EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

M2M SERVER

GPRS Maxi M2M-IP/50


GB50

METER 1 METER 2

METER 3

METER 4

EQUIPMENT 1

EQUIPMENT 2

SENSOR 1

SENSOR 2

Technical Information
M2M INTERFACE
FUNCTION MAX No. OF INPUTS MAX No. OF OUTPUTS DESCRIPTION 22 (4 to 20mA, 0 to 10VDC, 10k resistor, digital) 4 (volt free contact) 4 (pulse with modulation) 50 City Multi, Mr Slim and M Series (WxDxH) 300x70x350

MAX No. OF INDOOR UNITS COMPATIBILITY DIMENSIONS - mm

M2M INTERFACE - OPERATIONAL INFORMATION


FUNCTION NETWORK VARIABLE
On/Off Mode Operation Setpoint Adjustment Fan Speed Control Permit / Prohibit Airflow Direction Filter Sign

UP TO 25 GROUPS

UP TO 50 GROUPS

NOTES

Control
Run/Stop Cool / Dry / Heat / Auto / Fan Cooling 19-30C, Heating 17-28C, Auto 19-28C Lo-Mi1-Mi2-Hi On/Off, Mode, Setpoint Horizontal - 60,80,100 swing Normal/Reset

Monitor
On/Off Mode Operation Setpoint Adjustment Fan Speed Control Permit / Prohibit Airflow Direction Fault Code Filter Sign Room Temperature Run/Stop Cool / Dry / Heat / Auto / Fan Cooling 19-30C, Heating 17-28C, Auto 19-28C Lo-Mi1-Mi2-Hi On/Off, Mode, Setpoint Horizontal - 60,80,100 swing 4 Character code - Indicates all unit alarms -

M2M Software Options - Pin Code Activation


M2M - OS M2M - ES Optimised Start for Air Conditioning Energy Saving Capability

DEMONSTRATION
Visit m2m.mitsubishielectric.co.uk/demo to use the live demonstration space (login: demo / password: demo)

Page 248

M2M - Machine 2 Machine Splits Interface


Procon Mini M2M-A/16
TM

To offer remote management of its air conditioning units to companies with large numbers of dispersed offices, Mitsubishi Electric has adopted the M2M platform. The machine-to-machine (M2M) technology platform allows customers to integrate multiple sites into one network. The air conditioning units as well as third party equipment will be wirelessly connected to the M2M server and use the GPRS network to communicate.
Mini M2M-A/16
A1M A1M

MEUK M2M SERVER

METER 1 METER 2

METER 3

METER 4

EQUIPMENT 1

EQUIPMENT 2

SENSOR 1

SENSOR 2

GPRS

Mini M2M-A/16

A1M

A1M

METER 1 METER 2

METER 3

METER 4

EQUIPMENT 1

EQUIPMENT 2

SENSOR 1

SENSOR 2

Technical Information
M2M SPLITS INTERFACE
FUNCTION MAX No. OF INPUTS MAX No. OF OUTPUTS MAX No. OF INDOOR UNITS COMPATIBILITY DIMENSIONS - mm (WxDxH) DESCRIPTION 8 (4 to 20mA, 0 to 10VDC, 10k resistor, digital) 4 (pulse with modulation) 16 Mr Slim and M Series via Procon A1M 255x60x180

FUNCTION

NETWORK VARIABLE
On/Off Mode Operation Setpoint Adjustment

NOTES
Run/Stop Cool / Dry / Heat / Auto / Fan Cooling 19-30C Heating 17-28C Auto 19-28C

Control

Fan Speed Control Time Zone

Lo-Mi1-Mi2-Hi Weekly scheduling available

Monitor
On/Off Mode Operation Setpoint Adjustment Run/Stop Cool / Dry / Heat / Auto / Fan Cooling 19-30C Heating 17-28C Auto 19-28C Fan Speed Control Fault Code Room Temperature Time Zone Lo-Mi1-Mi2-Hi 4 Character code Indicates all unit alarms Weekly scheduling available

M2M Software Options - Pin Code Activation


M2M - OS M2M - ES Optimised Start for Air Conditioning Energy Saving Capability

DEMONSTRATION
Visit m2m.mitsubishielectric.co.uk/demo to use the live demonstration space (login: demo / password: demo) Page 249

M2M Interface / M2M Splits Interface

M2M SPLITS INTERFACE - OPERATIONAL INFORMATION

Controls Range 2008

M2M-Machine 2 Machine
MEUK Website Login

Web Screenshots

M2M is accessible using MEUK website.

A username and password is required to monitor and control sites.

Monitor Active Alarms and Sites

Status

All sites are listed with active alarm sites.

A site can be selected to monitor each system.

Set Parameters

Reports

Indoor unit and third party equipment can be controlled from the Website.

Reports can be generated for analysis.

Dashboard

Administration

G50/AG150/GB50 web pages are available for the air conditioning units

Using the administration level, the phone numbers and email of each duty engineer may be set and activated.

Technical Information
Page 250

G50 Control Panels


Mitsubishi Electric can supply G50 control panels (surface or internally mounted). This allows easy installation.

M-NET

G50 Control Panel

Technical Information
G50 CONTROL PANELS
MODEL GP50PS1 GP50PS2 GP50PS3 GP50PS4 GP50PI1 GP50PI2 GP50PI3 GP50PI4 GP50PSR1 GP50PSR2 GP50PSR3 GP50PSR4 GP50PIR1 GP50PIR2 GP50PIR3 GP50PIR4 No. OF G50 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 No. OF INDOOR UNITS 50 100 150 200 50 100 150 200 50 100 150 200 50 100 150 200 ROUTER NO NO NO NO NO NO NO NO YES YES YES YES YES YES YES YES MOUNTED Surface Surface Surface Surface Internally Internally Internally Internally Surface Surface Surface Surface Internally Internally Internally Internally DIMENSIONS (WxDxH) 600x200x600 600x200x600 800x250x600 800x250x600 600x200x600 600x200x600 800x250x600 800x250x600 600x200x600 600x200x600 800x250x600 800x250x600 600x200x600 600x200x600 800x250x600 800x250x600

Page 251

M2M Web Screenshots / G50 Control Panels

Controls Range 2008

Run / Standby Control Panels


The run/standby panel allows one system to run one week and the other one to run the other week. If one system fails, the run/standby panel will start the other one. If the temperature is too high, the panel will also start the 2 systems and enable an audible alarm.

Run / Standby Control Panel

Technical Information
RUN / STANDBY CONTROL PANELS
MODEL PANEL_RS1 PANEL_RS2 PANEL_RS3 No. OF SYSTEMS 2 3 4 RUN 1 2 3 STANDBY 1 1 1 HIGH TEMP YES YES YES ALARM YES YES YES DIMENSIONS (WxDxH) 400x210x600 500x210x700 500x210x700

Page 252

Energy Monitoring Control Panels


Energy monitoring is key to the compliance with Part L2. To perform energy monitoring; a lot of different products are required. To optimise the time of installation, Mitsubishi Electric can now supply an energy monitoring panel with energy meter, current transformers, breakers and the interface to the Mitsubishi Electric communication network.

Energy Monitoring Control Panel

M-NET

Power Supply

Technical Information
ENERGY MONITORING CONTROL PANELS
FUNCTION PANEL_EM100A PANEL_EM200A No. OF SYSTEMS 1 2 MAX RUNNING CURRENT (A) 100 200 DIMENSIONS (WxDxH) 600x210x800 600x210x800

Page 253

Run/Standby Control Panels / Energy Monitoring Control Panels

Controls Range 2008

Controls Range 2008

Split-System A2M Interfaces


The City Multi systems use advanced communication protocol called M-NET. The Split-Systems can be interfaced to M-NET, allowing compatibility with the main centralised controller (G50, AG150, GB50, TG2000). An A2M adapter would be required per outdoor unit for Mr Slim and per indoor unit for Mr Slim S Series or M Series indoor units.

PAC-SF80MA

Technical Information
SPLIT -SYSTEM A2M INTERFACES
FUNCTION COMPATIBILITY CONNECTION TO MNET SETTINGS DIMENSIONS - mm (WxDxH) PAC-SF80MA Mr Slim Outdoor Unit Outdoor Unit Rotary Switches 130x15x90 MAC-399IF Mr Slim S Series / M Series Indoor Unit Indoor Unit Dip Switches 160x55x70

Split-System A2M Interfaces

Page 254

Mitsubishi Electric Partner Programme


Open to all contractors - large or small - the Mitsubishi Electric Par tner Programme offers contractors a totally new and unique set of benefits. There are two categories within the programme - Accredited Installer and Business Solutions Partner - these levels being a straight-forward reflection of the Partners stage of growth, with all customers signing up to the programmes standards and committing to continued training and professional development.

For more information please contact your local sales office

Mitsubishi Electric Training Options


Mitsubishi Electric has four state-of-the-ar t training suites based at different locations around the countr y for your convenience. Providing training for all levels of exper tise, our courses are taught by experienced engineers, with a wealth of knowledge and are all CPD accredited.

For bookings please telephone 01707 278797

Systems marked with the ECA logo have an energy label of A or B, are registered on the Energy Technology List and hence qualify for 100% first year enhanced capital allowances (whole system cost and reasonable cost of installation). For further information please go to www.eca.gov.uk

Nominal conditions cooling: indoor 27C DB, 19C WB; outdoor 35C DB, 24C WB. Nominal conditions heating: indoor 20C DB; outdoor 7C DB, 6C WB. UK Conditions: Summer; indoor 21C DB, 15C WB; outdoor 27C DB. Winter; indoor 21C DB; outdoor -1C WB.

Notes: Recommended fuse ratings given throughout this price list are based on British Standard (BS88).

Telephone: 01707 282880


Post Sales Technical Support / Spares and Warranty: 0870 3000 300 email: air.conditioning@meuk.mee.com web: www.mitsubishielectric.co.uk/aircon

UNITED KINGDOM Mitsubishi Electric Europe Air Conditioning Systems Division Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England. General enquiries Telephone: 01707 282880 Fax: 01707 278674 IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 24, Ireland.
Telephone: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531)
Country of origin: United Kingdom Japan Thailand Malaysia. Mitsubishi Electric Europe 2008. Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B.V. The company reserves the right to make any variation in technical specification to the equipment described, or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are supplied subject to the Companys General Conditions of Sale, a copy of which is available on request. Third-party product and brand names may be trademarks or registered trademarks of their respective owners.