Você está na página 1de 8

MAIN LEG MEMBER (B/W support and end Phase conductor) Member designation Cg XX Cg YY Yield strength of steel Effective

length of buckling in XX dir Effective length of buckling in vv dir Radus of gyration, rxx Radus of gyration, rvv Outer to outer diatance B/n angles Hz Outer to outer diatance B/n angles Ver KL/rxx KL/rvv Design value of KL/r b t b/t ebsilan e (b/t)lim 75 = = = = = = = = = = = = = = = = = X 75 X 6 20.6 20.6 250 1666.7 833.3 23 14.6

mm mm Mpa mm mm mm mm

1000 mm 800 mm 72.47 57.08 72.47 75 mm 6 mm 12.5 1 13.28

Sqrt(250/Fy)

Maximum allowable slenderness Ce

IS 802 part1 sec2: 1992 cl. 5.2.2.1 > b/t henceOk = 125.6637 IS 802 part1 sec2: 1992 cl. 5.2.2

Allowable stress, Fa No of bolts along the width Assumed Dia of Bolt Assumed Dia of hole C/S area Area of connecting leg A1 Area of outstanding leg A2 Net cross/s area in tension (A1+A2) K = (3A1/(3A1+A2) Effective cross/s area in tension (A1+A2K) IS 802 part1 sec2: 1992 cl. 9.1 Permissible compression Permissible Tension

= 208 Mpa IS 802 part1 sec2: 1992 cl. 5.2.2 = 1 = 13 mm = 14 mm = = = = = = = = 864 mm2 348 mm2 432 mm2 780 mm2 0.707 654 mm2 18376 Kg 16672 Kg

C/C distance B/w angles Horizontally Vertical

= =

958.8 mm 758.8 mm

Permissible stresses in bolts of property class 5.6 as per table 3 IS 802 (part1)-1977 shear stress Bearing Stress Capacity of bolt In single shear In bearing Allowable shear on each Bolt Case1 withot deviation Vertical BM Horizontal BM Maximum compressive Force Maximum Tensile Force FOS against Comp FOS against Tension No. of Bolts Reqd. = = = = = = = Normal 2887.39 Kgm 9139.09 Kgm 9532 Kg 9532 Kg 1.93 <2 Not Ok 1.93 <2 Not Ok 4.12 4.45 1.30 <1.5 Not Ok Short circuit 2887.39 Kgm 12320.91 Kgm 12850 Kg 12850 Kg 1.43 <1.5 Not Ok (Taken directly from = design sheet) = 310 Mpa 436 Mpa

= = =

4194 Kg 3467 Kg 3467 Kg

MAIN LEG MEMBER (middle) Member designation Cg XX Cg YY Yield strength of steel Effective length of buckling in XX dir Effective length of buckling in vv dir Radus of gyration, rxx Radus of gyration, rvv Outer to outer diatance B/n angles Hz Outer to outer diatance B/n angles Ver KL/rxx KL/rvv Design value of KL/r b t b/t ebsilan e (b/t)lim 90 = = = = = = = = = = = = = = = = = X 90 X 6 24.2 24.2 250 2000 1000 27.7 17.5

mm mm Mpa mm mm mm mm

1000 mm 800 mm 72.20 57.14 72.20 X 75 mm 6 mm 12.5 1 13.28

Sqrt(250/Fy)

Maximum allowable slenderness Ce

IS 802 part1 sec2: 1992 cl. 5.2.2.1 > b/t henceOk = 125.6637 IS 802 part1 sec2: 1992 cl. 5.2.2

Allowable stress, Fa No of bolts along the width Assumed Dia of Bolt Assumed Dia of hole C/S area Area of connecting leg A1 Area of outstanding leg A2 Net cross/s area in tension (A1+A2) K = (3A1/(3A1+A2) Effective cross/s area in tension (A1+A2K) IS 802 part1 sec2: 1992 cl. 9.1 Permissible compression Permissible Tension

= 209 Mpa IS 802 part1 sec2: 1992 cl. 5.2.2 = 1 = 13 mm = 14 mm = = = = = = = = 1044 mm2 438 mm2 522 mm2 960 mm2 0.716 812 mm2 22237 Kg 20704 Kg

C/C distance B/w angles Horizontally Vertical

= =

951.6 mm 751.6 mm

Permissible stresses in bolts of property class 5.6 as per table 3 IS 802 (part1)-1977 shear stress Bearing Stress Dia of bolt Capacity of bolt In single shear In bearing Allowable shear on each Bolt Case1 withot deviation Vertical BM Horizontal BM Maximum compressive Force Maximum Tensile Force FOS against Comp FOS against Tension No. of Bolts Reqd. = = = = = = = Normal 4206.08 Kgm 12831.04 Kgm 13484 Kg 13484 Kg 1.65 <2 Not Ok 1.65 <2 Not Ok 4.74 4.97 1.17 <1.5 Not Ok Short circuit 4206.08 Kgm 16831.04 Kgm 17687 Kg 17687 Kg 1.26 <1.5 Not Ok (Taken directly from = design sheet) = = = = = 310 Mpa 436 Mpa 16 mm 6354 Kg 4267 Kg 4267 Kg

MAIN LEG MEMBER (middle) Member designation Cg XX Cg YY Yield strength of steel Effective length of buckling in XX dir Effective length of buckling in vv dir Radus of gyration, rxx Radus of gyration, rvv Outer to outer diatance B/n angles Hz Outer to outer diatance B/n angles Ver KL/rxx KL/rvv Design value of KL/r b t b/t ebsilan e (b/t)lim 45 = = = = = = = = = = = = = = = = = X 45 X 5 12.9 12.9 250 1255 1255 13.6 8.7

mm mm Mpa mm mm mm mm

1000 mm 800 mm 92.28 144.25 144.25 34.5 mm 5 mm 6.9 1 13.28

Sqrt(250/Fy)

Maximum allowable slenderness Ce

IS 802 part1 sec2: 1992 cl. 5.2.2.1 > b/t henceOk = 125.6637 IS 802 part1 sec2: 1992 cl. 5.2.2

Allowable stress, Fa No of bolts along the width Assumed Dia of Bolt Assumed Dia of hole C/S area Area of connecting leg A1 Area of outstanding leg A2 Net cross/s area in tension (A1+A2) K = (3A1/(3A1+A2) Effective cross/s area in tension (A1+A2K) IS 802 part1 sec2: 1992 cl. 9.1 Permissible compression Permissible Tension

= 95 Mpa IS 802 part1 sec2: 1992 cl. 5.2.2 = 1 = 13 mm = 14 mm = = = = = = = = 425 mm2 142.5 mm2 212.5 mm2 355 mm2 0.668 284 mm2 4114 Kg 7256 Kg

C/C distance B/w angles Horizontally Vertical

= =

974.2 mm 774.2 mm

Permissible stresses in bolts of property class 5.6 as per table 3 IS 802 (part1)-1977 shear stress Bearing Stress Dia of bolt Capacity of bolt In single shear In bearing Allowable shear on each Bolt Case1 withot deviation Vertical BM Horizontal BM Maximum compressive Force Maximum Tensile Force FOS against Comp FOS against Tension No. of Bolts Reqd. = = = = = = = Normal 4206.08 Kgm 12831.04 Kgm 13171 Kg 13171 Kg 0.31 <2 Not Ok 0.31 <2 Not Ok 5.56 5.83 0.42 <1.5 Not Ok Short circuit 4206.08 Kgm 16831.04 Kgm 17277 Kg 17277 Kg 0.24 <1.5 Not Ok (Taken directly from = design sheet) = = = = = 310 Mpa 436 Mpa 16 mm 6354 Kg 3556 Kg 3556 Kg

Reliability level(EHV transmission lines up to 400KV class) Terrain category As per specification;Design wind pressurePd Wind load on Tower or Girder Fwt=PdXCdtXAeXGT a) Pd=Design wind pressure in N/m2 b)Cdt=Drag co-efficient for pannel under consideration(From table 5) for solidity ratio c)Ae=total net surface area d)GT= Gust response factor(Height above ground 8.9m) Total area of Girder by considering boundery Exposed area for wind Solidity ratio Wind Pressure on tower (in kg) Wind Pressure on tower (in kn)

1 2 960 N/m2

2.58 0.286

1.92 9.71 m2 2.777 m2 0.286 485 KG/m2 4.76 KN/m2 (for total load this is to be multiplied by solidity

o be multiplied by solidity ratio)