SIMBOLOGIA / LEGENDA
SINALIZAÇÃO DE ABANDONO DE LOCAL E ILUMINAÇÃO DE EMERGÊNCIA
1206.6 PLACA INDICATIVA DE SAÍDA FACE ÚNICA (FOTOLUMINESCENTE)
SAÍDA
SAL-01 ALTURA DE INSTALAÇÃO H=2,20m
595.7 596 904.9
CLASSE II-B CLASSE II-B PLACA INDICATIVA DE SAÍDA FACE ÚNICA (FOTOLUMINESCENTE)
F.N.G FACHADA SEM GOTEJAMENTO ALVENARIA TRRF 60 MINUTOS F.N.G FACHADA SEM GOTEJAMENTO ALVENARIA TRRF 60 MINUTOS SAÍDA
SAL-02 ALTURA DE INSTALAÇÃO H=2,20m
34000
31879
GUARDA CORPO DE 1,10m
GUARDA CORPO DE 1,10m SAÍDA PLACA INDICATIVA DE SAÍDA FACE ÚNICA C/ SETA INDICATIVA À ESQUERDA
SAL-03 (FOTOLUMINESCENTE) ALTURA DE INSTALAÇÃO H=2,20m
CMAR DO AMBIENTE E TIPO USADO
h 1,60 m MAXIMO.
PLACA INDICATIVA DE SAÍDA FACE ÚNICA C/ SETA INDICATIVA À DIREITA
SAL-04 (FOTOLUMINESCENTE) ALTURA DE INSTALAÇÃO H=2,20m
PÓ PQS
CLASSE I CLASSE I
CLASSE II-A CLASSE II-B
3 HORAS
2 X16W
H= 2,20 m
PLACA INDICATIVA DE SAÍDA DUPLA FACE C/ SETA INDICATIVA À DIREITA
SAL-07 (FOTOLUMINESCENTE) ALTURA DE INSTALAÇÃO H=2,20m
H= 2,20 m
3 HORAS
2 X16W
LUMINÁRIA DE EMERGÊNCIA LED 2 X16W (BLOCO AUTÔNOMO) FLUXO LUMINOSO 2200 LUMENS
I E - 08 NIVEL DE ILUMINAMENTO MINIMO 5 LUX ALTURA DE INSTALAÇÃO H= 2,20 m
h = 2,20
3 horas
SAL-06
LUMINÁRIA DE EMERGÊNCIA 30 LED 1X2 W (BLOCO AUTÔNOMO) FLUXO LUMINOSO 200 LUMENS
I E - 09 NIVEL DE ILUMINAMENTO MINIMO 5 LUX ALTURA DE INSTALAÇÃO h= 2,20 m
OR
NT
TI
EX
CMAR
TO
EN
8 HAM
31250 31250
10 MIN
PAI - 10
m
P.A.I TÓXICOS / COEFICIENTE DE FRICÇÃO DINÂMICA (> 0,4 ÚMIDO / > 0,4 SECO)
CA
,8
CLASSE IV - A COEFICIENTE DE RESISTÊNCIA A ABRASÃO (PEI-4 ou PEI-5)
EXTREMIDADES NÃO PODEM
SER EM GANCHOS
(ACABAMENTOS A 45°)
AUT PNA - 11
CLASSE II-A PAREDE NÃO PROPAGENTE ALVENARIA
L 0.4 P.N.A
DF 01 SEM GOTEJAMENTO FLAMEJANTE
1229.1
NOTA:
OS GUARDA CORPO E
SEM GOTEJAMENTO
PARAPEITO NAO TERÃO T.N.J CLASSE II-A
CLASSE II-B ELEMENTOS FAZADOS MAIORES
F.N.G FACHADA SEM GOTEJAMENTO QUE 15 CM TNJ - 12 TETO DE LAJE NÃO PROPAGANTE
CLASSE II-B
C.F CF - 13
COBERTURA ESTRUTURA METÁLICA EM FIBROCIMENTO NÃO PROPAGANTE
H= 2,20 m
3 HORAS
( CORRIMÃO FIXADO NO GUARDA - CORPO ).
3 HORAS
2 X16W
H= 2,20 m
INSTALAÇÃO EM NICHO ALTURA DE INSTALAÇÃO h 1,60 m MAXIMO.
2 X16W
AUT 01
CAMINHAMENTO ALARME
L 0.3 COM DEMARCAÇÃO DE PISO
CMAR DO AMBIENTE E TIPO USADO DF 02
PÓ PQS BC 4Kg (CAPACIDADE EXTINTORA 20B:C) COM SINALIZAÇÃO DE PAREDE
21,37 m
PCF - 60
ALVENARIA TRRF 60 MINUTOS
CLASSE I CLASSE I
CLASSE II-A CLASSE II-B
90.6
42750
120.5
PÓ PQS
H = 0.18 m
CLASSE I CLASSE I
CLASSE II-B
CLASSE II-A
CAI-1 CENTRAL ENDEREÇAVEL - ALTURA DE INSTALAÇÃO h = 150 cm
P.A.I T.N.M C.F
2 X16W
H= 2,20 m
SAÍDA
h = 2,20
3 horas
H= 2,20 m
2473.4
2473.4
DE AMBOS OS LADOS DE AMBOS OS LADOS
2 X16W
251.3
2460
240
240
h 1,60 m MAXIMO.
H= 2,20 m
DE AMBOS OS LADOS CMAR DO AMBIENTE E TIPO USADO DE AMBOS OS LADOS
PCF - 60 ALTURA MÁXIMA DE INSTALAÇÃO 8,00 m.
DF 01
2 X16W
2x PÓ PQS
120.5
90.3
PÓ PQS
AUT
L 0.0 ACIONADOR MANUAL ENDEREÇAVEL 24 Vcc - ALTURA DE INSTALAÇÃO 120 a 150m.
L 0.3 AM 00 TIPO PUSH BUTTON
17 18 19 20 21 SOBE DF 04 CLASSE I CLASSE I
CLASSE II-A CLASSE II-B
17 18 19 20 21 22 23 24
P.A.I C.F CLASSE II-B INDICADOR SONORO E VISUAL ENDEREÇAVEL 24 Vcc - INTENSIDADE SONORA 115 dB - FREQUÊNCIA 500 Hz -
P.N.A T.N.M
1 L 0.0
ELETRODUTO EM COR VERMELHA APARENTE DE 2" EM AÇO GALVANIZADO F.N.G FACHADA SEM GOTEJAMENTO
AV 00 ALTURA MÁXIMA DE INSTALAÇÃO 5,00 m.
Ac01 SOBE
PCF - 60
42750
L 0.0
Lç 03 ISO 00 ISOLADOR DE LINHA ENDEREÇAVEL 24 Vcc
90.6 Ac01
ELE - AP-TE ELETRODUTO DE PVC RÍGIDO APARENTE - PINTADO NA COR VERMELHA - BITOLA Ø 3 4" -
OBS: AS PAREDES SÃO DE TIJOLO 8 FUROS CONTRUIDAS
EM 21 TIJOLO .
AUT
Lç 04 PVC-R Ø 3 4"
PARA SISTEMA DE ALARME DE INCÊNDIO.
3 HORAS
L 0.3
2 X16W
H= 2,20 m
ELE - AP-
DF 05 PVC-R Ø 3 4" ELETRODUTO APARENTE QUE, SOBE - DESCE - PASSA.
CABO DE COBRE BLINDADO 2 # 0,75 mm² + 2 # 1,5mm² - LAÇO DE ALARME DE INCÊNDIO - CONFORME NBR 17240
L - 0.0
Ø 0 0"
CLASSE I CLASSE I
CLASSE II-A CLASSE II-B
22879
AUT
L 0.4
DF 03
31250 31250
3 HORAS
2 X16W
H= 2,20 m
h = 2,20
SAL-07
3 horas
SAÍDAS DE EMERGÊNCIA ( CALCULOS )
h 1,60 m MAXIMO.
RESIDENCIAL A-2
UNIDADE DE PASSAGEM = 0,55 CM
PÓ PQS
6,15
8,90
POPULAÇÃO = 2 PESSOA PARA CADA DORMITÓRIO
PORTAS ESCADAS CORREDOR
N = P/A N = P/A N = P/A
ALVENARIA TRRF 60 MINUTOS
N = 16 / 60 N = 16 / 45 N = 16 / 100
GUARDA CORPO DE 1,10m ALVENARIA TRRF 60 MINUTOS
GUARDA CORPO DE 1,10m ALVENARIA TRRF 60 MINUTOS
N = 1X 55 N = 1 X 55 N = 1X 55
CLASSE II-B 900
F.N.G FACHADA SEM GOTEJAMENTO
CLASSE II-B
N = 80 CM N = 120 CM N = 120 CM
F.N.G FACHADA SEM GOTEJAMENTO
595.7 596
20cm
LETRA EM NEGRITO
180cm
DEPOSITAR
MATERAL
5 30 5
NIVEL DO PISO
BATERIA SELADA
DETALHE DO EXTINTOR DE INCÊNDIO 2 x 12 VCC - 2,2 Ah
SIRENE ÁUDIO VISUAL
ESC: 1/20
AUT AUT AUT AUT AUT
QUADRO DE ÁREAS
NOTA IN 18 : NOTA IN 14 : APARTAMENTO 01 64,50m²
APARTAMENTO 02 72,30m²
ESTA EDIFICAÇÃO ATENDE OS REQUISITOS APARTAMENTO 03 72,30m²
1. ESTA EDIFICAÇÃO ATENDE AOS REQUISISTOS
PREVISTO DA IN 14 ACERCA DA COMPARTIMENTAÇÃO APARTAMENTO 04 64,50m²
PREVISTOS NA IN 18 . ELETRODUTO APARENTE
VERTICAL. GARAGEM 01 153,08m²
PVC RÍGIDO Ø 3/4"
PINTADO VERMELHO
ELETRODUTO APARENTE MEZANINO 246,77m²
PVC RÍGIDO Ø 3/4" SALA COMERCIAL 131,63m²
PINTADO VERMELHO
NOTA IN 06: A FIXAÇÃO DO
SALÃO DE FESTAS 221,40m²
NOTA IN 28 : APARELHO DEVERÁ SER AREAS COMUM 48,89m²
DEVE-SE ATENDER A ESTA IN NO CASO DE NOTA IN 11 ART 06 :
OBRIGATORIEDADE DA BRIGADA DE INCÊNDIO.
INSTALADA COM PREVISÃO ÁREA TOTAL 1075,37m²
DE SUPORTAR 2,5 VEZES O CENTRAL DE
PESO TOTAL DO APARELHO ALARME DE INCÊNDIO
OBSERVAR A POPULAÇÃO PARA ENQUADRAMENTO A TENSÃO MÁXIMA DO SISTEMA DE ILUMINAÇÃO DE A SER INSTALADO
NA RESPECTIVA IN. POR PAVIMENTO
EMERGÊNCIA NÃO PODERÁ SER SUPERIOR A 30Vcc ,
CONFORME ART 06, IN 11. AUT AUT AUT
ACINADOR MANUAL
160cm (MÁXIMO)
20cm
UMA TOMADA EXCLUSIVA. PARA O SIE, COM DISJUNTOR DEVIDAMENTE DEPOSITAR OBSERVAÇÕES SOBRE O SISTEMA DE ALARME
MATERAL
IDENTIFICADO, INDEPENDENTEMENTE DO TIPO DE FONTE CIRCULO BRANCO COM BORDAS EM VERMELHO.
O ALARME SERÁ DO TIPO SIRENE ELETRÔNICA, SENDO QUE FORAM PREVISTO
02 12/06/2025 CONFORME INDEFERIMENTO OMAR VALMIRIA VALMIRIA
DE ENERGIA UTILIZADO, PODENDO SER COMPARTILHADO CIRCULO VERMELHO COM BORDAS EM BRANCO OU
DESTES AMBIENTES DEVE TER ACIONAMENTO 115 DB E FREQUÊNCIA DE 400 A 500 HERTZ COM MAIS OU MENOS 10% DE CASO O IMÓVEL NÃO POSSUA VIGILÂNCIA NUMERO ART 9858208-0 VALMIRIA DE L. KREISCH
ESTABELECIDOS NO ANEXO A, E INDICAR NO PROJETO O RESP. TÉC.
80 1
AUTOMÁTICO(SENSOR DE PRESENÇA) , CONFORME ART TOLERÂNCIA. TODA A FIAÇÃO DEVERÁ CORRER DENTRO DE ELETRODUTOS PERMANENTE RECOMENDA-SE QUE A CENTRAL DE
TIPO E AS CARACTERISTICAS MÍNIMAS NECESSÁRIAS AO
cm
1075,37m²
Data :
02/06/2025
e normas complementares para elaboração de projeto e NESTA EDIFICAÇÃO TODOS OS PAVIMETOS OCUPADOS APARELHOS PREVENTIVOS
execução do SCI. POSSUEM ABERTURAS PARA O EXTERIOR. Prancha:
Endereço obra: Logo: Des:
OMAR
RUA FAUSTA RATH, 183, SÃO CRISTOVÃO , LAGES -SC
OMAR 02/04 Nº De Pranchas:
02