WORK EXPERIENCE: 06/1990 -10/2006 11/2006 -08/2007 Algerian Oil& Gas Company SONATRACH senior electrical technician Dolphin energy limited ( Ras laffan Qatar) electrical technician electrical supervisor
Operation and maintenance for On-shore LNG Gas processing Trains, Utilities, Power generation, Storage and Loading facilities, and Gas processing & compression facilities. Routine, Preventive, Corrective and Breakdown maintenance, Troubleshooting and testing for all plant electrical systems and equipments such as : Generators (STG), Transformers, HV/LV Switch gears, Circuit breakers (ACB/VCB/GCB), HV/ LV Motors, Motor starter modules, Protection Relay, UPS and Batteries, Cathodic protection systems, Plant lightings, Power distribution etc. Electrical Isolation/De isolation and Earthing for all generation and distribution systems. Competent/Authorized Electrical Person certificate up to 6.6Kv (dolphin energy) Involved in Shutdown Maintenance of various Gas processing plant & Petro chemical plant Testing and Commissioning of Switch gears, Transformers, Switch gear sequence testing, Function testing, Control checking, Loop checking, Protection testing by
Primary and Secondary injection testing. Interface and Instrument Relay panel checking. Generator and auxiliaries pre-commissioning, Protection testing, Synchro checking and Load testing. Transformer Ratio checking, Oil checking, Temperature device and cooling system checking and protection testing. CT/PT ratio checking, Polarity checking, Magnetization checking. Control circuit checking, Loop checking, Alarm testing, Calibration for meters and Transducers, Protection Relay testing and setting, Hi pot testing. Involved for preparation of punch-list, test certificate for cables and equipments. Make sure the electrical connections and instrument connections as per vendor drawings, approved AFC drawings and operational requirements. Involved for checking and inspection of equipment installation, cable installation and verification of utility system as per client specification. Good interpersonal skills with the ability to relate well at all levels of an operational organization.. Minor Electrical installation and Modifications, Motor overhauling. Involved in Shutdown Maintenance of various Gas processing plant & Petro chemical plant
SKILLS :
-familiar with Micom&Sepam protection relay -GIS 33 KV with ILIS protection (AREVA) -ABB LV switchgear, MCU 1&2 and Insum system -MMI version 2.3 Modbus, Ethernet - PDCS load shedding function -Steam &gas turbine generator 43.75MVA (ABB, Mitsubishi) Transformer up 40-50 MVA (AREVA) -Motors up 3950 KW (ABB, ASI ROBINCON, TOSHIBA, SIEMENS, -Motor operated valve Rotork, Biffi -Variable speed drive ABB HITACHI) -DC UPS 48v dc, AC UPS 220 v ac up 180 KVA (Ceg Electronica, Chloride, Gutor) -
References :
Mr Mohammed sulaiman MAINTENANCE MANAGER DOLPHIN ENERGY QATAR e.mail : mohammed.sulaiman@dolphinenergy.com Mr Nizar saeed Electrical superintendent dolphin energy qatar e.mail: Nizar.saeed@dolphinenergy.com