Você está na página 1de 53

Name of Work: Construction of 300 gallon Vertical Mixer Building no.4 at SPROB.

Part

Mixer building

General Note:
1. Refer drawing for floor levels and heights. 2. Quantities indicated in the schedule are for all heights. Hence rates quoted shall include lift charges for all heights and no extra is admissible . 3. All the materials are to be got approved by Engineer-in-charge before incorporating in the work. 4. The rates quoted for all items should be for items finished in workman like manner inclusive of all leads, lifts and incidental charges/ expenditure. No extra payment is admissible on account of these. 5. No extra payment will be admissible for staging in all centering and formwork at all heights and levels, i.e., above finished floor level / GL upto topmost member of the structure and . Rates for items quoted should include this component irrespective of whether a specific mention is made or not in all the sub-heads / items for clarity. The drawings shall be read and rates quoted accordingly. No extra will be paid under any circumstances whatsoever. 6. No extra payment will be admissible for scaffolding and lift charges wherever applicable from finished floor level / GL upto top most level of the structure. Rates quoted for items should include this component. 7. The maximum moisture content in timber as per IS 287 of 1960 shall not exceed 12%. This should be ensured for all wood work. 8. Only coarse sand shall be used for all PCC works, RCC works, masonry works, and for external plastering works finished rough. 9. Fine sand shall be used for internal plastering work requiring smooth finish. 10. The centering (vertical props, bracings, etc.) shall be of steel tubes with or without extension pieces or builtup section of rolled steel for all load bearing RCC structural elements like beams, slabs, portals at height not less than 3m or span more than 3m (irrespective of height). However for minor RCC elements like lintels, chajjas etc., and slabs at height less than 3m from the support approved ballies may be used. The rate quoted for formwork shall be inclusive of providing steel props / bracings / ballies as the case may be for centering. 11. For cement concrete works M20 grade design mix should be adopted. The design mix details should be furnished by the contractor to Engineer-in-charge well in advance and should be got approved in time so that design mix details are available for adoption for all works in time. Reasonable time should be available for approval of Design mix by Engineer-in-charge from the date of submission of the proposal. It is the responsibility of construction agency to submit design mix proposals in time whenever approval for design mix is required. 12. Wherever the Brand names of materials or equivalent are stipulated, the materials of Brand names only shall be incorporated in the work. The equivalent material shall be permitted only on production of documentary evidence that the material of brand names stipulated are not under production. 13. "No working space shall be considered beyond the width of the foundation concrete (mudmat) shown in the drawings. The contractor shall consider working space if required while quoting the rate. The quoted rate shall include the quantity of earthwork to be done for working space if required and also for refilling the foundation. For payment, the measurement shall be restricted only to the foundation width shown in the drawings. No extra shall be permitted and measured for payment on account of working space / battering / benching for excavation and refilling around foundation. 14. Rates quoted shold include dewatering requirement if any for the work. No extra payment will be admissible toward this. 15. For all earthwork excavation items, no extra width towards working space will be considered for measurement. Payment will be made on the quantities measured as per drawing dimensions only. The quoted rate shall include these parameters. 16. All contractors workers /labours staff at site shall be provided with necessary personal protecting equipments such as safety helmets, safety shoes with steel capped has hand gloves, Safety belts.

No. of Additions: Signature of Tenderer Page shall firm inclusive of all taxes, duties and any other seignorage fee 17. The Rate/Amount Quoted for all the Items 1 No. of corrections: on materials No. of Over form Quarries etc., writings:

Name of Work: Construction of 300 gallon Vertical Mixer Building no.4 at SPROB.

Part

Mixer building

18. EIC.

Water tightness test to be conducted for Roof slab / Water Tank / GLR etc., at no extra cost all as directed by

ROAD WORK 1. Soling stone: Size of soling stone shall be normally between 100 mm to 225 mm size or as per approved size based on the site condition. The stacks shall be laid on a levelled ground and the net quantity is arrived at after deducting 15% towards voids / loose packing. The quantity shown under relevant item is the net quantity. In case stone of size from 90 mm to 45mm is used the deduction will be limited to 7.5% only. 2. Coarse aggregate: The size of coarse aggregate used for base course shall be varying from 63mm to 45mm and for II coarse the same shall be 53mm to 22.4mm. The stacks shall be laid on a leveled ground and the net quantity is arrived at after deducting 7.5% towards voids/loose packing. The quantity shown under relevant items is the net quantity. Rate quoted shall be for net quantity. 3. 13.2mm size aggregate: The quantity required for the WBM will be premeasured as per stack measurement. No voids are normally required to be made to arrive at the net quantity. For obtaining a good WBM coarse 13.2mm size aggregate shall be blinded with main coarse aggregate along with moorum. The minimum quantity of material required for the WBM per sqm of WBM course is indicated as follows.

1.) Base course (75mm consolidated thickness) i) 63mm to 45mm aggregate - 0.94cum/13.33sqm WBM area ii) 13.2mm aggregate - 0.135cum/13.33sqm WBM area 2.) II course (40 mm consolidated thickness) i) 50mm to 22.4mm aggregate - 0.94Cu.m/25 Sqm of WBM area ii) 13.2mm aggregate - 0.195Cu.m/25 Sqm of WBM area

4. 5.

The WBM item will be measured on square meter basis. Spreading of premix is to be done by using mechanical paver only.

6. Hot mix to be spread between 120 degree C-140 degree C and rolling operation should be completed before temperature fall below 100 degree C. 7. Wok will not be permitted in the cold atmosphere and in the late hours in the evening.

No. of Additions: No. of corrections: No. of Over writings:

Page 2

Signature of Tenderer

Name of Work : Construction of 300 gallon Vertical Mixer Building no.4 at SPROB.

Item No Part : A 0001

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Mixer building A001 10,000.000 Clearing Jungle including uprooting of rank vegetation, 2.18 SQM 21,800.00

grass, brush wood, trees and sapplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. (Note: If however, only grass is met with, the area will be measured and paid for, under as a separate item.)
0002 A003

Felling trees of the following girth (measured at a height of 1 M above ground level) including cutting of trunks and branches removing the roots, filling the pit and depression, stacking of the serviceable materials and disposal of unserviceable material etc., as directed for:
25.000 a) Felling Trees-beyond 30cm upto including 60cm 66.34 EACH 1,658.50

0002a

A003A

girth.
0002b A003B 10.000 b) Felling Trees-beyond 60cm up to including 120cm 292.70 EACH 2,927.00

girth.
0003a A004A 527.000 Providing and injecting Chemical emulsion for 118.91 SQM 62,665.57

0004a

A008A

PRE-CONSTRUCTIONAL Anti-termite treatement and creating a chemical barrier on top surface of plinth filling, junction of inside wall and floor, on top of damp proof course(DPC) or on masonry at the levelof plinth filling as per IS 6313(part-II)-1981 using chemicals like Chloropyripos emulsifiable (IS: 8944-1978) 20EC mixed with water in 1:19 ratio (i.e., 1 litre of Chemical to 19 litres of water). The emulsion is spread at 5 lit/sqm on top surface of plinth filling, top of Damp proof course and at 1 lit/linear meter along the junction of wall and floor, all as per specifications and directions. (Plinth area of the building at Ground floor only shall be measured) Note: The work shall be got executed through an agency having membership in India Pest Control Association (IPCA) and 10 years guarantee bond to be furnished. Earthwork in excavation for FOUNDATION TRENCHES in ALL KINDS OF SOILS including dressing of sides, ramming of bottom, disposing the surplus excavated materials within a distance of 50m and lift 1.50m complete as per specifications. (Disposed soil tobe levelled by breaking clods if any and neatly dressed).
620.000 Upto 1.5m below G.L. 215.000 From 1.5m to 3m below G.L. 132.18 CUM 149.71 CUM 81,951.60 32,187.65

0004aa 0004ab 0005

A008AA A008AB C010

Providing and laying cement concrete using 40mm nominal size graded hard granite stone aggregate obtained from approved quarry including compaction, finishing top surface to level, curing but excluding cost of formwork, etc; complete as per specifications. Mix ratio specified is for (cement: coarse sand: graded stone aggregate).
Page 3 04/25/12

98725

Item No Part : A 0005a

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Mixer building C010A 74.000 a) In foundation and plinth/sub-base to floors with 1,844.35 CUM C 130.00 2,262.75 CUM C 220.00 37.11 CUM 16,699.50 72,408.00 1,36,481.90

P.C.C 1:5:10
0005b C010C 32.000 b) In foundation and plinth/sub-base to floors with

P.C.C 1:3:6
0006a A010C 450.000 Filling available excavated approved earth (excluding

rock) in trenches, sides of foundations, plinth, etc; in layers not exceeding 15cms depth breaking clods, consolidating each deposited layer by ramming, watering and dressing, etc; complete for lead upto 50m and all lifts etc., complete as per specifications.
0007 B050

Providing and constructing BRICK MASONRY in cement mortar as per mixes stipulated below using approved well burnt bricks of "CLASS DESIGNATION" (Classification as per I.S.1077-1986) as specified below, including raking out joints 10mm deep wherever required curing, etc; complete all as per specifications in FOUNDATION AND PLINTH. (The mix ratio specified is for cement : coarse sand)
65.000 a ) U S I N G B R I C K S O F C L A S S D E S I G N A T I O N 1,997.10 CUM C 62.50 1,29,811.50

0007a

B050F

"4.5"(Minimum Average Compressive strength not less than 4.50 N/sqmm) In cement mortar 1:6
0008 B060

Providing and constructing BRICK MASONRY in cement mortar as per mixes stipulated below using approved well burnt bricks of "CLASS DESIGNATION" (Classification as per I.S. 1077-1986) as specified below including raking out joints 10mm deep, scaffolding, curing, etc; complete as per specifications IN SUPERSTRUCTURE UPTO FLOOR V LEVEL. (The mix ratio specified is for cement : coarse sand)
330.000 a ) U S I N G B R I C K S O F C L A S S D E S I G N A T I O N 2,255.65 CUM C 62.50 7,44,364.50

0008a

B060F

"4.5"(Minimum Average Compressive strength not less than 4.5 N/sqmm) In cement mortar 1:6
0009 E030

Providing rigid and water tight centering and shuttering using best quality wood/ plywood/ steel forms and centering with steel props, acro tubes etc., includingstrutting, propping, bracing, staging etc., compplete for all RCC items fixedin positionas required including labour for careful removal of form work etc., complete all as per specifications at all heights. In Horizontal / Vertical/ slanting surfaces.
380.000 a) Foundations, Footings, Bases of columns, Mass 63.19 SQM 24,012.20

0009a

E030A

concreting, Floorings etc.


0009b E030B 954.000 b) Lintels, Beams, Plinth Beams, Girders, Bressumers 103.51 SQM 98,748.54

and cantilevers.
0009c E030C 1,090.000 c) suspended floors, roofs, Balconies and access 134.62 SQM 1,46,735.80

platforms.
0009d E030D 915.000 b) Walls (any thickness) including attached pilasters, 117.94 SQM 1,07,915.10

buttresses plinth and string courses etc.


0009e E030E 853.000 d) Columns, Pillars, Abutments, posts and struts. 164.69 SQM 1,40,480.57

98725

Page 4

04/25/12

Item No Part : A 0010

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Mixer building F010

Steel reinforcement for all R.C.C items including decoiling, cutting, hooking, bending, cranking, fabricating to required shape, placing in position and tying the system with soft drawn annealed binding wire of diameter not less than 1.00mm with 2 strands etc; complete all as per specifications at all heights (binding wire will not be measured for payment).
130.000 a) With high yield strength deformed bars. 44,561.16 M.T T 1.00 57,92,950.80

0010a 0011

F010B D033

0011a 0011b

D033C D033A

Providing & laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, using graded hard granite stone aggregates of maximum 20mm nominal (down graded) size obtained from approved quarry including fine aggregates conforming to latest IS 383 and cement all as per approved design mix proportions conforming to latest IS 10262 with minimum cement content for durability including supplying and providing concrete cover blocks etc., which shall be followed as per latest IS456-2000 including mixing, transporting, placing, vibrating, compaction, finishing to required levels, curing etc.,complete all as per specifications but excluding cost of formwork and steel reinforcement. Rate to include labour for keeping embedments if any wherever required while casting. Rate also to include lift charges and scaffolding for all heights, depths, levels from FFL / GL. (The design mix proportions shall clearly indicate cement :fine aggregate : coarse aggregate : water cement ratio and approval shall be obtained from Engineer-in- charge for initial and subsequent mixes as and when there will be change in quarry / materials for M-35 grade reinforced cement concrete, etc. all works at all heights and depths. 357.000 a) All concrete elements upto plinth level.
235.000 b) Walls ( any thickness) including attached pilasters,

4,164.20 CUM C 380.00 4,340.01 CUM C 380.00

14,86,619.40 10,19,902.35

buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc.,

0011c

D033B

270.000 c) Beams, suspended floors, roofs having slope upto

4,492.82 CUM C 380.00

12,13,061.40

15 degree, landings, balconies, shelves, chajja, lintels, bands, plain window sills, staircases and spiral stair cases etc.,
0012 G080

98725

Providing and fixing steel door system made out of standard rolled steel sections. The door frame, shutter frame and diagonal stiffeners for the shutters, styles and rails and for shutters shall be MS angles/Tees. The shutter frame shall be coveredwith MS sheet (single/ double skin) electrically welded. The door frame shall have a base tie made out of 12mm square MS rod embedded in flooring and 3 nos. of 15mmx3.15mm lugs of 100mm long on each side embedded in cement concrete blocks of size 150x100x100mm of 1:3:6 mix (1 cement : 3 coarse sand : 6 hard granite stone aggregate 20mm nominal size) or, with anchor fasteners or with fixing clips with bolts and nuts as required. The work includes providing approved pivots as required and iron oxidized butt hinges 125mm long, 3 nos. for
Page 5

04/25/12

Item No Part : A

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Mixer building

0012a

G080A

each shutter conforming to IS 1341-1970 etc., including cutting the steel sections to required lengths, joints mitred and electrically welded, ground and cleaning the surface thoroughly free from rust scalesand painted with two coats of synthetic enamel over a coat of red oxide zinc chromate primer, after pre-treatment of the surface by pickling and phosphating, etc., conforming to IS specifications including providing and fixing MS aldrops, MS tower bolts and MS handles, etc., complete all as per specifications, drawings and instructions of Engineer in charge at all heights. 450.000 Fully openable (single/double) shutter and Using MS sheet coverd on single or both sides. Providing and fixing hollow metal pressed steel window system using 60 x 40 x 1.25mm edge folded CR (cold rolled) frames / mullions / transommes with single rebates to suit 50 x 20 x 1.25mm tubular box section shutters with sash bar of 'T' 20mmx3mmfor glazed shutters including, providing 12mm square MS guard bars at 120mm c/c welded to CR frames and mullions, providing glass of approved quality as specified below for shutters and providing and fixing powder coated MS latches, telescopic staysand handles (1 each per shutter) MS channel beadings of 10 x 10x 1.25mm for fixing glass in shutters. , The shutter shall be provided with antifriction pin type hinges. The hollow section of frame shall be filled with PCC 1:3:6 using 20mm grade aggregate and same shall be welded with 15 x 3.15mm lugs 100mm long embedded in cement concrete blocks 150 x 100 x 100mm of PCC 1:3:6 mix (1 cement : 3 coarse sand : 6 hard stone aggregate 20mm and down gauge). The entire steel works shall be dip phosphated and painted with 2 coats of zinc chromate primer etc., complete all as per specifications, drawings and directions of Engineer in charge at all heights in all floors.
40.000 S t e e l f u l l y g l a z e d p a r t l y o p e n a b l e a n d p a r t l y

54.94 KGS C 0.38

24,723.00

0013

G100

0013a

G100B

2,346.86 SQM C 10.00

93,874.40

fixedwindow/ ventilators with shutters top hung/ central hung/ side hung. with 4mm plain glass
0014 G115

Providing and fixing hollow metal pressed steel lovered ventilators using 60 x 40 x 1.25mm edge folded CR (cold rolled) frames / mullions / transommes with single rebates including providing 12mm square MS guard bars at 120mm c/c welded to CR framesand mullions, providing glass of approved quality as specified below for lovers and fixing with MS channels louvers holdersas specified in drawing on one side including , providing and fixing 1/16" x 24G GI fly mosquito proof wire mesh using MS channel beadings of 10 x 10 x 1.25mm on the other side. The hollow section of the frame shall be filled with PCC 1:3:6 using 200 agreegate and , same welded with 15x3.15mm lugs 100mm long embedded in cement concrete blocks 150 x 100 x 100mm of PCC 1:3:6 mix (1 cement : 3 coarse sand : 6 hard stone aggregate 20mm and down gauge). The entire steel works shall be dip phosphated and painted with 2 coats of zinc chromate primer etc., complete all as per specifications, drawings and directions of Engineer in charge at all heights in all floors.
Page 6 04/25/12

98725

Item No Part : A 0014a

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Mixer building G115A 15.000 Steel fully glazed louverd ventilator with MS channel 2,252.57 SQM C 7.00 33,788.55

louver holders With 4 mm thk pin headed glass


0015 T065

0015a

T065A

Providing and fixing at all heights/ in all floors with all leads Anodised Aluminium doors/ windows/ partitions manufactured from best extruded Aluminium sections confirming to ISI, cut to length, joints mitred and corners grinded with joints water proof the outer frame and shutter frame stiffened with corner angle strips or provided for in the frame for fixing the frame to R.C.C Columns/ masonry on sides, , RCC lintels on top and P.C.C cills or floor at bottom, the frame work fixed with standard approved fastenings all generally as per details shown in drawings and specification with all the sections pretreated for removal of any rust and prevention of further rust formation and coated with greasy materials for non-adherence of mortar orany other sticky materials and , this coat to be removed after installations of the sub-dividing frames by tennoned and rivetted into frames all aluminium surface be thoroughly cleaned free or rust scale or dirt and mill scale by pickling surfaces finished with anodised dull matt finishing 15 MICRON thick including cost of pull and push plates and fixtures for hinged openings (arrangement with steel bearings wherever necessary), cost of labour for fixing of mortice lever locks, aluminium handles, door fittings like tower bolts etc., supplied free for fixing including screws / bolts (Or these materials measured separately elsewhere) where shutters are involved etc., complete ,, cost of providing and fixing of glass of selected glazing quality of thickness and type of glass specified hereinafter or panel boards including nylon or PVC or rubber lining of approved quality wooden grounds, rubber gasket, aluminium glazing clips, mastic etc., and fixing with aluminium glazing clips and alsosnap-on type with holes as per drawing and specifications provided for separately in the sub items following the main items of frame workfor partition and door shutters as below: NOTE: All fitting works shall be carried out as per I.S specifications including necessary rivets, screws, lugs, scaffolding, etc., complete all generally as per drawings. The sizes of the components should confirm as per details in drawings. 150.000 a) Providing and fixing of Anodised Aluminium (Matt finish) frame work (Horizontal and verticals) for partitions Doors /Windows with required sections of JINDAL/ INDAL make or equivalent including allitems and contingencies described above complete (Aluminium beadings and glazing clips measured under this item only)
100.000 b) Providing and fixing of frame work ( Styles and rails)

389.72 KGS

58,458.00

0015b

T065B

390.38 KGS

39,038.00

for Doors shuters/window shutters with required sections of JINDAL/ INDAL make or equivalent including providing all items and hinged / pivoted arrangements for operation of shutters and labour cost for fixing of door fittings and locks ( Which shall be free issues for fixing or paid separately) etc., complete. (Aluminium beadings and glazing clips measured under this item only.)

98725

Page 7

04/25/12

Item No Part : A 0015c

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Mixer building T065C 10.000 c) Providing and fixing Glass panes of selected glazing 443.26 SQM 4,432.60

quality and thickness as specified below including providing and fixingNylon/rubber/ PVC lining of approved quality and fixing with Aluminium glazing clips/ Aluminium beadings (Supply cost of Aluminium clips/ Aluminium beadings are measured in items for DOORS / WINDOWS/ PARTITIONS etc., Using 4mm thick plain glass
0016a H225A 292.000 Providing and laying (carborundum based) 40mm thick 501.05 SQM C 17.90 1,46,306.60

hardonite non-metallic monolithic flooring for heavy traffic using Nitoflor Hardtop of M/s. FOSROC Chemicals or equivalent consisting of 40mm thick base of cement concrete 1:2:4 laid to level in bays not exceeding 3sqm per panel including providing 3mm thick aluminium dividing strips to the full depth of flooring including applying a layer of Nitoflor Hardtop Powder at 5kg / sqm on the surface immediately when the surface is green and finishingby power trowel to the required finish and level etc.,, and after 24 hours a lithium based liquid floor hardener "Nitoflor LH" of M/s. Fosroc Chemicals or equivalent shall be spread at the rate of 100 ml per sqm on the surface and allowed to saturate and dry for 2 hours.The buffing shall be carried out after 24 hours of providing the nitoflor-LH to get the required shining etc.,complete all as per manufacturers specifications anddirections of Engineer in charge.
0017 H060

Providing and laying Indian patent stone flooring with cement concrete 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) using graded granite stone aggregate obtained from approved quarry laid to level or slope in bays not exceeding 3sqm per panel including providing 3mm thick Aluminium dividing strips to the full depth of the flooring and finished smooth, curing, etc; complete all as per specifications.
315.000 a) 40mm thick (Using 20mm nominal size stone 240.18 SQM C 15.00 621.11 SQM 99,377.60 75,656.70

0017a

H060C

aggregate)
0018a H300A 160.000 P r o v i d i n g a n d l a y i n g 2 m m t h i c k A N T S T A T I C

0019

K005

POLYVINYL SHEET manufcatured by M/s. Premider Polyfilm Ltd. / Birla Corporation Ltd. or equivalent on a smooth & damp proof base using rubber based Adhesives (@ 0.2 kg/sqm) of approved quality and manufacturer like Dunlop S-758, Fevicol SR-998 or equivalent including cleaning, levelling, drying of the base, rolling with light wooden roller weighing about 5.00 kg including providing copper strip of size 15mm x 2mm for earthing etc. all complete as per specification and the directions of the Engineer-in-Charge and haing the following properties for the sheet:, (1) Electrical Resistance - Anti-Statitic flooring range 5x10 ^4 - 10^8 Ohms, conductive flooring range upto 5 x 10^4 Ohms (2) Flexibility -Does not break, crack or any sign of failure (3) Heat Ageing & Exudation - No visible effect or exudation (4) Fire resistance - Does not support combustion or assist spread of flame (5) Water absorption - less than 0.1% (6) Sound reduction factor -2mm - 3 db. Plastering 12mm thick with cement mortar specified below, finished smooth including scaffolding,
Page 8 04/25/12

98725

Item No Part : A

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Mixer building

0019a 0020

K005C K015

curing, etc; complete for INTERNAL SURFACES of walls, beam, ribs, sills, jambs, ceiling, etc; complete all as per specifications at allheights. Mix specified is for cement : fine sand NOTE: i) CM 1:3 OR CM 1:4 is generally applicable for ceilings and RCC surfaces unless otherwise specified. 2,382.000 a) With C.M 1:4. Plastering 15mm thick with cement mortar specified below, finished smooth including scaffolding, curing, etc; complete for INTERNAL SURFACES of walls, beam ribs, sills, jambs, etc; complete all as per specifications at all heights mixspecified is for Cement : Fine Sand NOTE: i) CM 1:3 OR CM 1:4 is generally applicable for ceilings and RCC surfaces unless otherwise specified.
1,775.000 a) With C.M. 1:5 500.000 b) With C.M. 1:4

71.93 SQM C 5.47

1,71,337.26

0020a 0020b 0021

K015B K015C K025

77.86 SQM C 5.33 83.44 SQM C 6.54

1,38,201.50 41,720.00

Plastering 20mm thick with cement mortar specified below finished smooth including scaffolding, curing, etc; complete for INTERNAL SURFACES of stone masonry/brick masonry walls, sills, jambs, etc; complete all as per specifications atall heights Mix specified is for cement : fine sand. NOTE: i) CM 1:3 OR CM 1:4 is generally applicable for ceilings andRCC surfaces unless otherwise specified.
2,300.000 a) With C.M. 1:5. 94.89 SQM C 6.94 2,18,247.00

0021a 0022

K025B K040

Water proof cement plastering of thickness as specified below in cement mortar 1:3 (1 cement : 3 coarse sand) mixed with approved water proofing compound such as CICO or ACCOPROOF or equivalent as per manufacturers specifications including scaffolding, curing, etc; complete for EXTERNAL SURFACES all as per specifications UPTO 10 MTR LEVEL ABOVE G.L.
613.000 a) 20mm thick 590.000 White washing with lime (fat lime class-C) three or 118.91 SQM C 11.42 19.28 SQM 72,891.83 11,375.20

0022a 0023a

K040A K070A

more coats to give an even shade to walls and ceilings including scaffolding, cleaning the surface, cost of lime powder and gum, etc; complete all as per specifications.
0024a K295A 3,047.000 Painting internal plastered surfaces with two or more 48.75 SQM 1,48,541.25

coats of super acrylic emulsion paint of approved brand and colour (Berger or Asian or equivalent) to give an even shade with required finish over a coat of water thinnable cement primer includingcleaning the surfaces, filling the crevices with approved filler, scaffolding, curing, etc.,complete all as per specifications.
0025a K300A 2,575.000 Painting external plastered surfaces with two or more 55.30 SQM 1,42,397.50

coats of 100% acrylic exterior emulsion paint of approved make and colour (weather coat of Berger or apcolite apex of Asian or equivalent) having protection against fungal growth, flaking, fading,alkali and UV degradation and to give an even shade with required finish including cleaning the surfaces,
98725 Page 9 04/25/12

Item No Part : A

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Mixer building

0026a

K150A

filling the crevices with approved filler, scaffolding, curing, etc., complete all as per specifications. 80.000 Painting steel work with TWO or more coats of SYNTHETIC ENAMEL PAINT of I quality and approved colour to give an even shade over a coat of red oxide zinc chromate primer including cleaning the surfaces, applying a coat of approved putty on whole surface and rubbing the surface to achive desired smooth surface, scaffolding, etc; complete all as per specifications ( Rate to include cost of zinc chromate primer, putty also). Providing and laying light duty Non-pressure NP-2 Class R.C.C Hume pipes with collars jointed with stiff mixture of C.M. 1:2 (1 cement:2 fine sand) including joints, etc; complete.
50.000 a) 150mm dia 30.000 b) 450mm dia 20.000 c) 300mm dia 180.000 Providing and laying angular fillet 7.5x7.5cm cement

57.73 SQM

4,618.40

0027

O010

0027a 0027b 0027c 0028a

O010B O010E O010D L035A

267.59 MTR C 0.60 598.25 MTR C 2.40 347.88 MTR C 1.10 9.77 RMT C 0.90

13,379.50 17,947.50 6,957.60 1,758.60

concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate) 20mm nominal size, including compaction, finishing, curing, etc; complete all as per specifications.
0029 K305

Providing plaster drip/ moulding of size as specified below in cement mortar 1:3 (1 cement :3 fine sand) including scafolding ,curing etc, complete all as per specifications ,drawings and direction of Engineer -in -charge.
180.000 a ) 45mmx15mm size 12.43 RMT C 1.50 2,237.40

0029a 0030

K305A J220

Providing and fixing rigid PVC SWR (soil, waste and rain water) drainage / rain water pipe conforming to Type-A IS 13592-1992, including accessories like bends and fixing with pipe clips, adhesive at joints all as per manufacturer's specifications torequired length etc., complete all as per specifications and directions of Engineer in charge.
130.000 c) 160mm dia OD pipes with minimum wall thickness 333.75 RMT C 6.88 43,387.50

0030a

J220C

of 3.20 mm
0031 D050

Extra for mixing water proofing compound of approved quality and brand in R.C.C items with ROFFE HYPROOF manufactured by M/s. Roffe Construction Chemicals Pvt. Ltd. at 140ml per 50kgs of cement or CONPLAST X 421 IC of Fosroc Chemicals ltd. at 130ml per 50 kgs of cement or equivalent approved make mixed with cement as per manufacturer's specifications etc., complete all as per specifications. (Rate to include the cost of water proofing compound).
65.000 a) In M-35 grade concrete 106.85 CUM 6,945.25

0031a 0032

D050E B010

Providing and constructing RANDOM RUBBLE MASONRY using hard granite stones obtained from approved quarry with bond stones at every 0.50
Page 10 04/25/12

98725

Item No Part : A

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Mixer building

0032a 0033

B010A N075

sqm of wall surface in cement mortar in mixes stipulated below without pinning on face, but including raking out joints and pointing flush in same mortar including curing, etc; complete as per specifications in FOUNDATION AND PLINTH. (Rate includes cost of bond stones wherever provided). (Mix ratio specified is for cement : coarse sand) 34.000 a) In cement mortar 1:6. Supplying and filling gravel obtained from approved quarry in layers not exceeding 150mm in depth consolidating each layer by ramming with frog rammer, watering and dressing etc; complete including all leads and lifts and all as per specifications.
73.000 a) Under floors/In plinth protection.

1,701.91 CUM C 82.50

57,864.94

0033a 0034

N075A H050

280.27 CUM

20,459.71

0034a 0035

H050A F035

Providing and laying cement concrete in pavements and ramps in panels not exceeding 10sqm per panel and plinth protection in panels not exceeding 3sqm per panel using graded hard granite stone aggregate including providing necessary formwork, making 10mm wide grooves in panels for depth of 1/3 rd of thickness of pavement or 40mm which ever is more and filling the grooves with approved hot poured sealing compound confirming to grade A or B of IS-1834, consolidation, curing and treatment for the topwith broom finish, etc; complete all as per specifications, Mix ratio specified is for (cement: coarse sand: graded stone aggregate). 7.000 a) Using 20mm nominal size agreegate In CC 1:3:6. Supplying, fabricating, assembling, hoisting/erecting and fixing in position at all heights and with all leads, structural steel works of welded built-up sections, all as per structural drawings and as per detailed specifications (for materials and workmanship) in the situations described hereinafter including a)cutting of components to required lengths/widths and shapes/profiles, b)smooth machining of edges/faces , , c) welding (electric arc welding) at joints of built-up sections/single sections for required weld lengths and sizes and d) painting all over with two coats of Synthetic enamel paint of approved quality , make and colour/shade over one coat of red oxidezinc chromate primer with surfaces duly prepared to receive painting etc.,complete all as directed by the Engineer-in-charge , NOTE : The Contractor shall submit fabrication shop drawings for work involved based on construction drawings (that may be issued during construction period) for approval by Engineer-in-charge.The fabrication work shall start only after approval to the fabrication drawings. Any change required in the fabrication drawings shall be carried out at no extra cost over the quoted rates., Fabrication shall be in a perfectly workmanship like manner and as provided in Section V and VI of IS 800 and IS 7215. Welding shall be carried out by qualified welders. Electrodes for welding, the procedure, selection, test and inspection shall conform to provisions in IS 816, IS 818, IS 822, and IS 833.Erection/hoisting shall commence only after passing of fabricated parts by the Engineer -in- charge.
Page 11

2,769.55 CUM C 320.00

19,386.85

98725

04/25/12

Item No Part : A 0035a

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Mixer building F035A 6.750 a) Structural steel works of built up and framed 56,954.02 M.T 3,84,439.64

Stanchions/ Columns/ Trusses/ Girders/ Portals etc., in welded built up sections fabricated with R.S. Joists (ISMB/ ISWB/ ISHB).
0035b F035B 1.150 b) Structural steel works and welded built up sections 56,954.02 M.T 65,497.12

in items but with MS Plates of any thickness.

0035c

F035H

1.500 c) Structural steel works as in item above but with MS

47,588.49 M.T

71,382.74

angles tees and other sections.


0035d F035M 0.750 d) Structural steel works of supports for CABLE 46,522.91 M.T 34,892.18

TRENCH COVERS/DRAIN COVERS fabricated with single sections of MS angles tees and other sections.

0035e

F035E

2.500 e ) S t r u c t u r a l s t e e l w o r k s o f C A B L E T R E N C H

56,711.22 M.T

1,41,778.05

COVERS/DRAIN COVERS with Chequered MS Plates and welded connection/joints.


0035f F035F 300.000 f)Structural steel work of factory made MS Holding 53.18 KGS 15,954.00

down foundation bolts including nuts and washer plates of any dia including necessary threading and machining
0035g F035G 1.450 g) Structural steel works as in item above but with MS 51,323.39 M.T 74,418.92

Channels
0036 F040

Providing and fixing hand rail by welding etc., to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved (zinc chromate) steel primer etc.and as per specication of item no 0035 above with:
750.000 a) M.S tube (medium): 40 mm nominal bore . 45.12 KGS 33,840.00

0036a 0037 0037a

F040A J200 J200A

90.000 Providing and laying water proofing treatment over

346.91 SQM C 23.43

31,221.90

RCC roof in 3 courses, as specified below, after thoroughly cleaning surface of the roof slab with wire brush, cleaning of dust and foreign matters, raking and cleaning of construction joints if anyetc., complete to make the surface suitable for receiving water proofing treatment., I COURSE : The existing covering on slab to be removed and the surface of the RCC slab exposed. Construction joints if any are to be raked and cleaned. A coat of cement slurry at the rate of 4.4kg/sqm mixed with acrylic water proofing compound (as per manufacturers specification) is spreaduniformly over the RCC roof area and ensuring that the slurry penetrates into the RCC slab below and fills all micro cracksand all other porous areas. Over this a layer of 15mm thick cement mortar 1:5, mixed with acrylic water proofing compound as per manufacturers specifications shall be laid to place the II course. , IICOURSE : A sinle layer of brick on edge with 15mmwide gaps filled with CM 1:5 mixed with acrylic water compound is laid (i.e., bricks placed vertically on its 75x115mm side or 75x230mm side as the case may be, to suit the required thickness of course), when the bottom layer (I course) is still green and laid to slope of 1 in 60 as per roof drainage scheme using approved
98725 Page 12

04/25/12

Item No Part : A

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Mixer building

0038

A030

well burnt bricks (water absorption not more than 20%) with minimum thickness of 65mm at outer edge including the top and bottom plastering (I & III course) to get required gradient, laying the bricks with not less than 15mm gap alround, which shall be properly filled completely and compacted with CM 1:5 mixed with acrylic water proofing compound as per manufacturersspecification using full bricks or bricks cut to required size to lay the course with single layer with gradient said above for adequate drainage., III COURSE : 20mm thick cement motar 1:4 mixed with acrylic water proofing compound with a layer of chicken mesh 12mmx26G and marked with 300mmx300mm false squares including curing etc., for not less than 7 days, complete all as per specifications and directions of Engineer in charge. The 20mm thick layershall be carried out in two layers of 10mm thick with an inter layerof chicken mesh of 12mmx26G laidin between the two layers of cement mortar. Note: The Acrylic water proofing compound to be used shall be: a) CHEMSEAL - manufactured by M/s. Overseas water proofing Corporation, Mumbai. The proportion of CHEMSEAL shall be 2% by weight of cement OR CONPLAST X 421 IC - Integral waterproofing compound manufactured by M/s. FOSROC Chemcials, (India) Ltd., Bangalore. The proportion of CONPLAST X 421 IC shall be 130ml per 50kg of cement. OR ROFF Hyproof manufactured by M/s. ROFFE Construction Chemcials Pvt. Ltd. liquid integral water proofing compound @140ml/50kg of cement OR Equivalent b) The second course of the treatment shall be laid in single course using full bricks / cut bricks as may be required for laying the course in 1 in 60 slope. c) The rate to include all labour, material and contingent costs for execution of work in a workman like manner including curing etc., complete for respective courses. d) The plane horizontal measurments of roof slab only shall be measured for payment. e) The theoratical cement consumption required for the above work will be worked out based on co-efficient for each layer of work as per specification. f) The work shall be got executed through specialised water proofing agency. g) The contractor should furnish a guarantee bond in the prescribed format for satisfactory water proofing performance for 300.000 Filling excavated approved earth (excluding rock) 10 years. bought from out side 4 km lead in trenches, sides of foundations, plinth, etc; in layers not exceeding 15cms depth breaking clods, consolidating each deposited layer by ramming, watering and dressing, etc; complete and all lifts etc., complete as per specifications. Providing and fixing M-20/M-35 grade Precast Reinforced cement concrete using graded hard Granite stone aggregate of 20mm nominal size obtained from approved quarry including mechanical mixing, centering and shuttering, compaction, simultaneously finishing smooth with 6mm thick cement plaster 1:3 (1 cement: 3 fine sand) on exposed surfaces and , fixing in position with same C.M 1:3, curing etc., complete all as per specifications but excluding cost of steel
Page 13

119.37 CUM

35,811.00

0039

D037

98725

04/25/12

Item No Part : A

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Mixer building

reinforcement at all heights.


0039a 0039b 0040 D037A D037B J081 7.000 a) for cable trench cover slabs M-20 grade etc., 3.000 b) for cable trench cover slabs M-35 grade etc., 550.000 P r o v i d i n g M a r v e l I n s u l - K o a t o r e q u i v a l e n t 5,185.41 CUM C 382.00 5,406.73 CUM C 390.00 363.83 SQM 36,297.87 16,220.19 2,00,106.50

brand-Elestomeric Thermal insulation and water resistance and solar reflective aluminium coating which includes the material. 1. Marvel/or equivalent Super Shield- /elastomeric polymer cementitious water proofing lining. 2. Marvel/or equivalent GFM (40 GSM) two diamentional reinforcement mesh. 3. Marvel/or equivalent Supercrete HR, 4. Marvel/or equivalent flexibond at all heights including necessary scaffolding, staging from FGL/NGL. The work includes the following. (i) Surface Preparation: To chip out the existing loose plastering free from the surface and to clean the surface free from the dust, fungus, dirt and other foreign matters. Materials: 1. Marvel/or equivalent Super Shield-elastomeric polymer cementitious water proofing lining. 2. Marvel/or equivalent GFM (40 GSM) two diamentional reinforcement mesh. 3. Marvel/or equivalent Supercrete HR 4. Marvel/or equivalent flexibond Application: (ii) Cornor Treatment Chipping out unsound plaster on corners and making it sound by using rich mortar admixed with Latex Polymer 3 Ltr per bag of cement used. Application of Marvel or equivalent Super Shield: 1st Polymar Slurry Coat: To mix Marvel/or equivalent Super Shield polymer @ the proportion of 1:2:2 (One part of MARVEL/OR EQUIVALENT SUPER SHIELD : Two part of OP cement : Two part of water) mixing it well using mechanical stirrer when the mix at homogeneous stage applying to the surface treatment area. 2nd Polymar Slurry Coat: To mix Marvel/or equivalent Super Shield polymer @ the proportion of 1:1 (One part of MARVEL/OR EQUIVALENT SUPER SHIELD : One part of OP cement ) mixing it well using mechanical stirrer when the mix at homogeneous stage applying to the surface treatment area. Laying two diamensional reinforcement: Marvel or equivalent GFM MESH: Fixing up the Two Dimensional reinforcement MARVEL or equivalent GFM mesh over the Super Shield slurry coat when it is touch green condition. Application of Second Coat: To mix Marvel/or equivalent SUPER SHIELD polymer @ the proportion Page 14 of 1:1 (One part of MARVEL/OR EQUIVALENT SUPER SHIELD : One part of OP

98725

04/25/12

Item No Part : A

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Mixer building

0041

Z457

0042a

K280A

cement ) mixing it well using mechanical stirrer when the mix at homogeneous stage applying to the surface treatment area and allow it to dry for 12 hours interval. Application of MARVEL / or equivalent supercrete HR Heat cum waterproofing compound: To apply one coat of MARVEL/ or equivalent Supercrete HR diluted with 60% of water which is nano technology base polysiloxane reacts with cementitious substrate and all nano particles penetrate into capillary and forms hydrophobility and allow it to dry for 4 hours interval. Application of Marvel / or equivalent flexi bond: To apply top one coat of Marvel or equivalent Flexibond-elestomeric heat reflective cum water proof lining which forms thermal insulation and water resistance. Application of water based solar reflective Aluminium coat: To apply Two top coats of Solar Reflective Water Based Aluminium Coating at the Wet film thickness of 100 Micron per each coat by giving proper interval of 12 hours as per manufacturer's instructions. 1. The colour of Top most finish coat shall be of "Galvnised steel" shade 2. The product sample is enclosed for reference. 3. The tenderers are required to do a mock up sample based on the department requirement before award of work. Note: Gaurantee for 1 year shall be given for a) Reflection of Aluminium coating and for b) Water proofing membrane, the guarantee period shall be for 5 years. 90.000 Providing and fixing 3mm thick soild polycarbonate sheet such as -TUFLITE or equivalent of thermal transmittance. U value 5.49 W/sqmo K and thermal condensating density 1.2 g/Cm3 (Colour bronze) including fixing arrangement as per manufacturer specifications, i.e aluminium powder coated sections (i.e., hat section at top and hollow rectangular section at bottom along every width of sheet with neoprene washer, bolts & nuts etc.,) including fixing to structural members with 'J' hooks/neoprene cup type washers at top etc., complete all as per directions of Engineer-in-Charge. 300.000 Providing and fixing GI hexagonal chicken wire mesh of size 12mm x22g at the junction of disimilar surfaces of brick masonry wall and R C C column by beams and the like including necessary nails for fixing etc, complete all as per specification anddirection of Engineer -in -charge for all floor at all heights. Earth work in Excavation over AREAS (exceeding 30 cms in depth, 1.50 mtr width as well as 10 sqm on plan) in ALL KINDS OF SOIL upto a depth not exceeding 1.50 mtr including disposal of excavated earth, lead upto 50 mtrs and lift upto 1.50 mtr etc., complete all as per specifications. (Disposed earth to be levelled by breaking clods if any and neatly dressed).
75.000 a) upto 1.50m below GL 100.000 b) 1.50m to 3.0m below GL

3,638.25 SQM

3,27,442.50

43.71 SQM

13,113.00

0043a

A005A

0043aa 0043ab

A005AA A005AB

130.13 CUM 143.14 CUM

9,759.75 14,314.00

98725

Page 15

04/25/12

Item No Part : A 0044

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Mixer building K020

Plastering 15mm thick with cement mortar specified below finished rough including scaffolding, curing, etc; complete for EXTERNAL SURFACES of walls, inclusive of sills, jambs, soffits, etc; complete all as per specifications for heights upto 10 mtr above GL. Mix specified is for cement : coarse sand. NOTE: i) CM 1:3 OR CM 1:4 is generally applicable for ceilings and RCC surfaces unless otherwise specified.
275.000 a) With C.M. 1:4 81.80 SQM C 6.54 22,495.00

0044a 0045

K020C C020

Providing and laying cement concrete using 20mm nominal size graded hard granite stone aggregate obtained from approved quarry including compaction, finishing top surface to level, curing but excluding cost of formwork, etc; complete all as per specifications. Mix ratio specified is for (cement:coarse sand:graded stone aggregate).
10.000 a) In foundation and plinth/sub-base to floors with 2,463.27 CUM C 220.00 24,632.70

0045a

C020A

P.C.C. 1:3:6
0046 B090

0046a

B090D

Providing and constructing HALF BRICK MASONRY walls/partitions in the following mixes using FIRST CLASS well burnt bricks of "CLASS DESIGNATION" (Classification as per I.S. 1077-1986) as specified below including scaffolding, raking out joints, curing, etc; complete with R.C.C 1:2:4 (1 cement:2 sand:4 graded stone aggregate of 20mm nominal size) stiffeners of size 115mmx75mm at every 900mm centers including formwork M.S reinforcement consisting of 2 nos. of 6mm dia M.S bars for main reinforcement with 6mm dia M.S links at 230mm c/c for each R.C.C stiffener etc; complete as per specifications in SUPERSTRUCTURE UPTO FLOOR-V LEVEL.( The mix ratio specified is for Cement : Coarse sand ) 40.000 a) USING BRICKS OF "CLASS DESIGNATION 4.5"(Minimum Average Compressive strength not less than 4.5 N/sqmm) In cement mortar 1:4
Total of Part : A

324.59 SQM C 12.60

12,983.60

1,46,15,292.78

98725

Page 16

04/25/12

Item No Part : B 0001a

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Earthern Merlon A005A

Earth work in Excavation over AREAS (exceeding 30 cms in depth, 1.50 mtr width as well as 10 sqm on plan) in ALL KINDS OF SOIL upto a depth not exceeding 1.50 mtr including disposal of excavated earth, lead upto 50 mtrs and lift upto 1.50 mtr etc., complete all as per specifications. (Disposed earth to be levelled by breaking clods if any and neatly dressed).
320.000 a) upto 1.50m below GL 130.13 CUM 41,641.60

0001aa 0002

A005AA C010

Providing and laying cement concrete using 40mm nominal size graded hard granite stone aggregate obtained from approved quarry including compaction, finishing top surface to level, curing but excluding cost of formwork, etc; complete as per specifications. Mix ratio specified is for (cement: coarse sand: graded stone aggregate).
52.000 a) In foundation and plinth/sub-base to floors with 1,844.35 CUM C 130.00 95,906.20

0002a

C010A

P.C.C 1:5:10
0003 E030

Providing rigid and water tight centering and shuttering using best quality wood/ plywood/ steel forms and centering with steel props, acro tubes etc., includingstrutting, propping, bracing, staging etc., compplete for all RCC items fixedin positionas required including labour for careful removal of form work etc., complete all as per specifications at all heights. In Horizontal / Vertical/ slanting surfaces.
67.000 a) Foundations, Footings, Bases of columns, Mass 63.19 SQM 4,233.73

0003a

E030A

concreting, Floorings etc.


0004 B020

0004a 0005

B020A K060

Providing and constructing RANDOM RUBBLE MASONRY using hard granite stones obtained from approved quarry with bond stones at 2 mtr apart in cement mortar in mixes stipulated below without pinning on face, but including raking out joints including curing, scaffolding, etc; complete as per specifications IN SUPERSTRUCTURE UPTO FLOOR V LEVEL. (Rate includes cost of bond stones wherever provided.The mix ratio specified is for cement:coarse sand) Dressing of stones and quoins shall be as follows: ,DRESSING: Stone shall be hammer dressed on the face, the sides and the beds, to enable it to come into close proximity with the neighbouring stone. The bushing in the face shall not project more than 4 cm on an exposed face and 1 cm on a face, to beplastered. The hammer dressed stone shall also have a rough tooling for a minimum width of 2.5cm along the 4 edges of the face of stone. , Quoins: Neatly dressed with the hammer or chisel to form the required angle and laid header and stretcher alternately. Theses stones shall have a minimum of 2.5 cm wide chisel draft at 4 edges, all the edges being in 250.000 the same plane. a) In cement mortar 1:6. Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) including raking out joints, scaffolding, curing, finishing neat, etc; complete all as per specifications UPTO 10 MTR LEVEL ABOVE G.L

2,006.07 CUM C 82.50

5,01,517.50

98725

Page 17

04/25/12

Item No Part : B 0005a 0006

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Earthern Merlon K060A C045 370.000 a) Flush pointing. 55.11 SQM C 1.53 20,390.70

Providing and laying cement concrete using graded hard granite stone aggregate of 20mm nominal size obtained from approved quarry including formwork, compaction, finishing, curing, etc; IN BED BLOCKS, ANCHOR BLOCKS, WINDOW CILLS, COPING BLOCKS, etc;upto floor-V level complete all as per specifications. Mix ratio specified is for (cement:coarse sand:graded stone aggregate) The work includes providing throating/ drip mould whereever required as per standard engineering practiceof size not be lessthan 40mm X 15mm. The rate is inclusive for making drip mould & no extra cost will be paid for.
10.000 a) P.C.C 1:3:6 2,843.11 CUM C 220.00 28,431.10

0006a 0007

C045A K020

Plastering 15mm thick with cement mortar specified below finished rough including scaffolding, curing, etc; complete for EXTERNAL SURFACES of walls, inclusive of sills, jambs, soffits, etc; complete all as per specifications for heights upto 10 mtr above GL. Mix specified is for cement : coarse sand. NOTE: i) CM 1:3 OR CM 1:4 is generally applicable for ceilings and RCC surfaces unless otherwise specified.
40.000 a) With C.M. 1:6 4,300.000 Earth filling in MERLONS with approved earth (with a 71.43 SQM C 4.30 85.02 CUM 2,857.20 3,65,586.00

0007a 0008a

K020A A010B

lead not less than 5km) at optimum moisture content in layers not exceeding 20cms in thickness consolidating each layer by ramming in dovetail sections using frogrammer, watering and finishing to required slope including necessary excavation of earth, sectioning with all lifts and lead not less than 5KM etc., complete all as per specifications.Note:- The deductions towards voids shall be made as per CED specifications.
0009a N040A 2,200.000 Providing 150mm thick gravel topping over merlons, 89.99 SQM 1,97,978.00

watering, consolidating and finishing to required slope and level, etc; including all leads and lifts, complete all as per specifications.
0010 B010

Providing and constructing RANDOM RUBBLE MASONRY using hard granite stones obtained from approved quarry with bond stones at every 0.50 sqm of wall surface in cement mortar in mixes stipulated below without pinning on face, but including raking out joints and pointing flush in same mortar including curing, etc; complete as per specifications in FOUNDATION AND PLINTH. (Rate includes cost of bond stones wherever provided). (Mix ratio specified is for cement : coarse sand)
144.000 a) In cement mortar 1:6. 65.000 Providing and fixing 75mm dia (O.D) Unplasticised 1,701.91 CUM C 82.50 135.77 RMT 2,45,075.04 8,825.05

0010a 0011a

B010A J185A

PVC pipe water spouts conforming to IS 4985-1988 inclusive of specials (Tee) confirming to IS 7834 (part-IV)-1987 of working pressure 6kg/sqcm. The outlet end shall be provided with PVC Tee and the inlet end shall be flush with inner face of
98725 Page 18 04/25/12

Item No Part : B

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Earthern Merlon

facias/parapets, fixing in cement mortar 1:3 etc; complete all as per specifications. provided as weap holes in RR masonary at all heights.
Total of Part : B 15,12,442.12

98725

Page 19

04/25/12

Item No Part : C 0001

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Control room A001 1,000.000 Clearing Jungle including uprooting of rank vegetation, 2.18 SQM 2,180.00

grass, brush wood, trees and sapplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. (Note: If however, only grass is met with, the area will be measured and paid for, under as a separate item.)
0002 A003

Felling trees of the following girth (measured at a height of 1 M above ground level) including cutting of trunks and branches removing the roots, filling the pit and depression, stacking of the serviceable materials and disposal of unserviceable material etc., as directed for:
15.000 a) Felling Trees-beyond 30cm upto including 60cm 66.34 EACH 995.10

0002a

A003A

girth.
0002b A003B 10.000 b) Felling Trees-beyond 60cm up to including 120cm 292.70 EACH 2,927.00

girth.
0003a A004A 230.000 Providing and injecting Chemical emulsion for 118.91 SQM 27,349.30

0004a

A008A

PRE-CONSTRUCTIONAL Anti-termite treatement and creating a chemical barrier on top surface of plinth filling, junction of inside wall and floor, on top of damp proof course(DPC) or on masonry at the levelof plinth filling as per IS 6313(part-II)-1981 using chemicals like Chloropyripos emulsifiable (IS: 8944-1978) 20EC mixed with water in 1:19 ratio (i.e., 1 litre of Chemical to 19 litres of water). The emulsion is spread at 5 lit/sqm on top surface of plinth filling, top of Damp proof course and at 1 lit/linear meter along the junction of wall and floor, all as per specifications and directions. (Plinth area of the building at Ground floor only shall be measured) Note: The work shall be got executed through an agency having membership in India Pest Control Association (IPCA) and 10 years guarantee bond to be furnished. Earthwork in excavation for FOUNDATION TRENCHES in ALL KINDS OF SOILS including dressing of sides, ramming of bottom, disposing the surplus excavated materials within a distance of 50m and lift 1.50m complete as per specifications. (Disposed soil tobe levelled by breaking clods if any and neatly dressed).
170.000 a) Upto 1.5m below G.L. 115.22 CUM 19,587.40

0004aa 0005

A008AA C010

Providing and laying cement concrete using 40mm nominal size graded hard granite stone aggregate obtained from approved quarry including compaction, finishing top surface to level, curing but excluding cost of formwork, etc; complete as per specifications. Mix ratio specified is for (cement: coarse sand: graded stone aggregate).
57.000 a) In foundation and plinth/sub-base to floors with 1,844.35 CUM C 130.00 1,05,127.95

0005a

C010A

P.C.C 1:5:10
0006 E030

Providing rigid and water tight centering and shuttering using best quality wood/ plywood/ steel forms and centering with steel props, acro tubes
Page 20 04/25/12

98725

Item No Part : C

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Control room

0006a

E030A

etc., includingstrutting, propping, bracing, staging etc., compplete for all RCC items fixedin positionas required including labour for careful removal of form work etc., complete all as per specifications at all heights. In Horizontal / Vertical/ slanting surfaces. 208.000 a) Foundations, Footings, Bases of columns, Mass concreting, Floorings etc.
350.000 b) Lintels, Beams, Plinth Beams, Girders, Bressumers

63.19 SQM

13,143.52

0006b

E030B

103.51 SQM

36,228.50

and cantilevers.
0006c E030C 290.000 c) suspended floors, roofs, Balconies and access 134.62 SQM 39,039.80

platforms.
0006d 0006e E030E E030D 120.000 d) Columns, Pillars, Abutments, posts and struts. 85.000 b) Walls (any thickness) including attached pilasters, 164.69 SQM 117.94 SQM 19,762.80 10,024.90

buttresses plinth and string courses etc.


0007 D033

0007a 0007b

D033C D033A

Providing & laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, using graded hard granite stone aggregates of maximum 20mm nominal (down graded) size obtained from approved quarry including fine aggregates conforming to latest IS 383 and cement all as per approved design mix proportions conforming to latest IS 10262 with minimum cement content for durability including supplying and providing concrete cover blocks etc., which shall be followed as per latest IS456-2000 including mixing, transporting, placing, vibrating, compaction, finishing to required levels, curing etc.,complete all as per specifications but excluding cost of formwork and steel reinforcement. Rate to include labour for keeping embedments if any wherever required while casting. Rate also to include lift charges and scaffolding for all heights, depths, levels from FFL / GL. (The design mix proportions shall clearly indicate cement :fine aggregate : coarse aggregate : water cement ratio and approval shall be obtained from Engineer-in- charge for initial and subsequent mixes as and when there will be change in quarry / materials for M-35 grade reinforced cement concrete, etc. all works at all height and depths. 80.000 a) Up to plinth level
10.000 b) Walls ( any thickness) including attached pilasters,

4,164.20 CUM C 380.00 4,340.01 CUM C 380.00

3,33,136.00 43,400.10

buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc.,

0007c

D033B

71.000 c) Beams, suspended floors, roofs having slope upto

4,492.82 CUM C 380.00

3,18,990.22

15 degree, landings, balconies, shelves, chajja, lintels, bands, plain window sills, staircases and spiral stair cases etc.,
0008 B050

Providing and constructing BRICK MASONRY in cement mortar as per mixes stipulated below using approved well burnt bricks of "CLASS DESIGNATION" (Classification as per I.S.1077-1986) as specified below, including raking out joints 10mm deep wherever required curing, etc;
Page 21 04/25/12

98725

Item No Part : C

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Control room

0008a

B050F

complete all as per specifications in FOUNDATION AND PLINTH. (The mix ratio specified is for cement : coarse sand) 5.000 a ) U S I N G B R I C K S O F C L A S S D E S I G N A T I O N "4.5"(Minimum Average Compressive strength not less than 4.50 N/sqmm) In cement mortar 1:6 Providing and constructing BRICK MASONRY in cement mortar as per mixes stipulated below using approved well burnt bricks of "CLASS DESIGNATION" (Classification as per I.S. 1077-1986) as specified below including raking out joints 10mm deep, scaffolding, curing, etc; complete as per specifications IN SUPERSTRUCTURE UPTO FLOOR V LEVEL. (The mix ratio specified is for cement : coarse sand)
50.000 a ) U S I N G B R I C K S O F C L A S S D E S I G N A T I O N

1,997.10 CUM C 62.50

9,985.50

0009

B060

0009a

B060F

2,255.65 CUM C 62.50

1,12,782.50

"4.5"(Minimum Average Compressive strength not less than 4.5 N/sqmm) In cement mortar 1:6
0010 B090

0010a

B090D

Providing and constructing HALF BRICK MASONRY walls/partitions in the following mixes using FIRST CLASS well burnt bricks of "CLASS DESIGNATION" (Classification as per I.S. 1077-1986) as specified below including scaffolding, raking out joints, curing, etc; complete with R.C.C 1:2:4 (1 cement:2 sand:4 graded stone aggregate of 20mm nominal size) stiffeners of size 115mmx75mm at every 900mm centers including formwork M.S reinforcement consisting of 2 nos. of 6mm dia M.S bars for main reinforcement with 6mm dia M.S links at 230mm c/c for each R.C.C stiffener etc; complete as per specifications in SUPERSTRUCTURE UPTO FLOOR-V LEVEL.( The mix ratio specified is for Cement : Coarse sand ) 150.000 U S I N G B R I C K S O F " C L A S S D E S I G N A T I O N 4.5"(Minimum Average Compressive strength not less than 4.5 N/sqmm) In cement mortar 1:4
150.000 Filling available excavated approved earth (excluding

324.59 SQM C 12.60

48,688.50

0011a

A010C

37.11 CUM

5,566.50

rock) in trenches, sides of foundations, plinth, etc; in layers not exceeding 15cms depth breaking clods, consolidating each deposited layer by ramming, watering and dressing, etc; complete for lead upto 50m and all lifts etc., complete as per specifications.
0012 K005

Plastering 12mm thick with cement mortar specified below, finished smooth including scaffolding, curing, etc; complete for INTERNAL SURFACES of walls, beam, ribs, sills, jambs, ceiling, etc; complete all as per specifications at allheights. Mix specified is for cement : fine sand NOTE: i) CM 1:3 OR CM 1:4 is generally applicable for ceilings and RCC surfaces unless otherwise specified.
375.000 a) With C.M 1:5. 425.000 b) With C.M 1:4. 67.24 SQM C 4.46 71.93 SQM C 5.47 25,215.00 30,570.25

0012a 0012b 0013

K005B K005C K015

Plastering 15mm thick with cement mortar specified below, finished smooth including scaffolding, curing, etc; complete for INTERNAL SURFACES of walls,
Page 22 04/25/12

98725

Item No Part : C

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Control room

0013a 0014

K015B K020

beam ribs, sills, jambs, etc; complete all as per specifications at all heights mixspecified is for Cement : Fine Sand NOTE: i) CM 1:3 OR CM 1:4 is generally applicable for ceilings and RCC surfaces unless otherwise specified. 50.000 a) With C.M. 1:5 Plastering 15mm thick with cement mortar specified below finished rough including scaffolding, curing, etc; complete for EXTERNAL SURFACES of walls, inclusive of sills, jambs, soffits, etc; complete all as per specifications for heights upto 10 mtr above GL. Mix specified is for cement : coarse sand. NOTE: i) CM 1:3 OR CM 1:4 is generally applicable for ceilings and RCC surfaces unless otherwise specified.
270.000 a) With C.M. 1:5 280.000 Providing and laying water proofing treatment over

77.86 SQM C 5.33

3,893.00

0014a 0015a

K020B J200A

65.99 SQM C 5.33 346.91 SQM C 23.43

17,817.30 97,134.80

98725

RCC roof in 3 courses, as specified below, after thoroughly cleaning surface of the roof slab with wire brush, cleaning of dust and foreign matters, raking and cleaning of construction joints if anyetc., complete to make the surface suitable for receiving water proofing treatment., I COURSE : The existing covering on slab to be removed and the surface of the RCC slab exposed. Construction joints if any are to be raked and cleaned. A coat of cement slurry at the rate of 4.4kg/sqm mixed with acrylic water proofing compound (as per manufacturers specification) is spreaduniformly over the RCC roof area and ensuring that the slurry penetrates into the RCC slab below and fills all micro cracksand all other porous areas. Over this a layer of 15mm thick cement mortar 1:5, mixed with acrylic water proofing compound as per manufacturers specifications shall be laid to place the II course. , IICOURSE : A sinle layer of brick on edge with 15mmwide gaps filled with CM 1:5 mixed with acrylic water compound is laid (i.e., bricks placed vertically on its 75x115mm side or 75x230mm side as the case may be, to suit the required thickness of course), when the bottom layer (I course) is still green and laid to slope of 1 in 60 as per roof drainage scheme using approved well burnt bricks (water absorption not more than 20%) with minimum thickness of 65mm at outer edge including the top and bottom plastering (I & III course) to get required gradient, laying the bricks with not less than 15mm gap alround, which shall be properly filled completely and compacted with CM 1:5 mixed with acrylic water proofing compound as per manufacturersspecification using full bricks or bricks cut to required size to lay the course with single layer with gradient said above for adequate drainage., III COURSE : 20mm thick cement motar 1:4 mixed with acrylic water proofing compound with a layer of chicken mesh 12mmx26G and marked with 300mmx300mm false squares including curing etc., for not less than 7 days, complete all as per specifications and directions of Engineer in charge. The 20mm thick layershall be carried out in two layers of 10mm thick with an inter layerof chicken mesh of 12mmx26G laidin between the two layers of cement mortar. Note: The Acrylic water23 Page proofing compound to be

04/25/12

Item No Part : C

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Control room

0016

F010

used shall be: a) CHEMSEAL - manufactured by M/s. Overseas water proofing Corporation, Mumbai. The proportion of CHEMSEAL shall be 2% by weight of cement OR CONPLAST X 421 IC - Integral waterproofing compound manufactured by M/s. FOSROC Chemcials, (India) Ltd., Bangalore. The proportion of CONPLAST X 421 IC shall be 130ml per 50kg of cement. OR ROFF Hyproof manufactured by M/s. ROFFE Construction Chemcials Pvt. Ltd. liquid integral water proofing compound @140ml/50kg of cement OR Equivalent b) The second course of the treatment shall be laid in single course using full bricks / cut bricks as may be required for laying the course in 1 in 60 slope. c) The rate to include all labour, material and contingent costs for execution of work in a workman like manner including curing etc., complete for respective courses. d) The plane horizontal measurments of roof slab only shall be measured for payment. e) The theoratical cement consumption required for the above work will be worked out based on co-efficient for each layer of work as per specification. f) The work shall be got executed through specialised water proofing agency. g) The contractor should furnish a guarantee bond in the prescribed format for satisfactory water proofing performance for 10 years. Steel reinforcement for all R.C.C items including decoiling, cutting, hooking, bending, cranking, fabricating to required shape, placing in position and tying the system with soft drawn annealed binding wire of diameter not less than 1.00mm with 2 strands etc; complete all as per specifications at all heights (binding wire will not be measured for payment).

0016a 0017

F010B J085

30.000 a) With high yield strength deformed bars.

44,561.16 M.T T 1.00

13,36,834.80

Providing and laying under deck thermal insulation at all heights/ floors using 50mm thick resin bonded fibre glass of density 24kg/ cum (UP TWIGA or equivalent) or resin bonded mineral wool of density 48kgs/ cum as per IS:8183 in slab form (manufactured by M/s. Rockwool India Ltd. or M/s. LLoyd insulation (India) Ltd.) insulation as indicated below for thermal insulation, wool placed on top/ back of AC sheets/ E boards using , polythene bags in grids of required size as per drawing using seasoned IInd class teak wood / Ist class Country wood frame work of 65mm wide 50mm deep reapers/ using materials for frame work including fixing by means as specified below including placing the fibre glass/ mineral wool along with 6mm thick plain A.C.sheet/ 4mm thick E board over the frame work including paintingthe wood work with one coat of suitable primer, etc; complete all as per drawings and specifications.
600.000 Providing and fixing framework for underdeck thermal 46.83 KGS 28,098.00

0017a

J085I

insulation made out of MS structural steel work consisting of ISA 25x25x5mm for wall angles, ISNT-40 at 1220mm c/c both ways in grids and also with residual grids as per drawings/ directions. The MS Tees/ Angles are to be welded to MS cleats made out of ISA 60x90x6mm, 60mm long (with a hole drilled in cleat for 8mm dia bolt to be fixed from anchor fasteners) welded to MS Tees and Angles
98725 Page 24 04/25/12

Item No Part : C

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Control room

0017b

J085J

at 1220mm c/c suspended from 8mm dia anchor fasteners with bolts and nuts,aligning, levelling the frame work, painting the steel works with, two or more coats of synthetic enamel paint over a coat of red oxide zinc chromate primer etc., complete all as per specifications, drawings and directions of Engineer in charge. NOTE: (a) Anchor fasteners shall be measured seperately. (b) Quantity of MS frame work including cleats is about 7.25kg/sqm 110.000 Providing and fixing 8mm dia (internal) anchor fasteners of M/S Hilti make or equivalent to RCC slabs/ beams/ brick walls etc., to take a safe working load (SWL) of not less than 200kgs including supply and fixing with both ends threaded bolts of 75mm long and nuts to fix in anchor fastener and to MS cleat in MS frame work etc., complete. NOTE: 1. While fixing the bolts the gap of approximate 48mm required for fixing mineral wool and AC sheet/ boards on MS frame work is to be maintained. 2. Anchor fasteners with bolts & nuts and cleats are to be fixed at all nodes for both wall angles and Tees. Number of anchor fasteners with bolt and nuts will be about 1.39 Nos. / sqm)
75.000 Providing and fixing 50mm thick resin bonded fibre

27.58 EACH

3,033.80

0017c

J085D

375.52 SQM

28,164.00

glass /mineral wool insulation of density as specified below including placing the wool on AC sheet or E board in polythene bag ( using 250 micron LDPE sheet of 0.92 g/ cc ) including supply of polythene bag etc, copmlete .( Area of fibre glass /mineral wool in between the members of frame work only will be measured for payment ), Using 50 mm thick mineral wool of density 48 kg / cum as per IS 8183 in slab form of M/S rock wool India ltd or M/SLloyd insulation (INDIA) ltd or Equivalent.
0017d J085F 75.000 Providing fixing 4 mm thick plain E-board over the 377.10 SQM 28,282.50

frame work specified and painted on exposed surface and edges except surface on which glass fibre by mineral wool is placed.
0018a K300A 316.000 Painting external plastered surfaces with two or more 55.30 SQM 17,474.80

coats of 100% acrylic exterior emulsion paint of approved make and colour (weather coat of Berger or apcolite apex of Asian or equivalent) having protection against fungal growth, flaking, fading,alkali and UV degradation and to give an even shade with required finish including cleaning the surfaces, filling the crevices with approved filler, scaffolding, curing, etc., complete all as per specifications.
0019a K295A 625.000 Painting internal plastered surfaces with two or more 48.75 SQM 30,468.75

coats of super acrylic emulsion paint of approved brand and colour (Berger or Asian or equivalent) to give an even shade with required finish over a coat of water thinnable cement primer includingcleaning the surfaces, filling the crevices with approved filler, scaffolding, curing, etc.,complete all as per specifications.
0020a T100A 8.000 Supplying of factory made composite door shutter with 2,728.69 SQM 21,829.52

frame and single shutter manufactured by M/s. Fimen Fibre Products Pvt. Ltd., or equivalent with door frame of size 70x50mm. The door shutter shall be of rigid G.R.P sandwich composite structureof 26mm thick (minimum) laminated on all sides with
98725 Page 25 04/25/12

Item No Part : C

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Control room

0021

I245

G.R.P skin fabricated using U.V. stabilized Isopthalic gel coat and one layer of 450 GSM E glass chopped strand mat (CSM) impregnated with polyster resin. , The thickness of skins shall not be lessthan 1.5mm. Expanded polysterene structural foam panel of density 20kg/cum shall be used as core material for the whole areas of door except the wooden frame structure. The wooden reinforcements made of seasoned salwood block of minimum cross section of 70x26 for lock side 40x26 all round forming the framework for shutter and minimum of 75mm wide intermediate strip for the width of the door for fixing locks and fixture and shall confirm to IS-4020-1998. The finish of the shutter be without grains and of approved colour etc., complete all as per manufacturers specifications at all heights. Providing and fixing M.S grills of required pattern in wooden / steel frames of windows, ventilators, clerestorey windows, etc; with M.S flats, square or round bars with round headed bolts and nuts or by screws, etc; complete all as per drawings anddirections of Engineer-in-charge.
400.000 a) Plain grill (With vertical, horizontal members or a 52.50 KGS 21,000.00

0021a

I245A

combination of both)
0022a I055A 0.650 ProvidingASCU treated seasoned first class country 44,944.25 CUM 29,213.76

0023

G050

wood(agisa) in frames of doors, windows, ventilators and other frames like partition etc; wrought, framed and fixed in position with 40mmx3mm and 400mm long MS holdfasts embedded in cement concreteblocks of size 345/ 230/ 115mm x 230mm x 150mm in PCC 1:3:6 mix for wall locations. Further if the frames are butting to the RCC/PCC columns/ mullions, 8mm dia anchor fastner shall be provided instead of hold fasts or with M.S bolts/T.W plugs and G.I. screws as required including tarring back of the frames, etc; complete all as per specifications. Providing and fixing pivoted steel windows/ ventilators side hung/ central hung/ top hung made out of standard rolled steel sections joints mitred and electrically welded with 15 x 3.15mm lugs 100mm long embedded in cement concrete blocks 150 x 100 x100mm of 1:3:6 mix (1 cement: 3 coarse sand : 6 hard stone aggregate 20mm and down gauge) or with wooden plugs and screws or with anchor fasteners or with fixing clips with bolts and nuts as required including, providing and fixing selected glazingquality glass panes of specified thickness with standard aluminium beadings of size 10 x 10 x 1mm necessary approved pivots as required and projected hinges, weather bars, etc; in windows/ ventilators including cleaning the surface thoroughly free from rust scales by pickling and phosphating and painted with two coats of ready mixed red oxide zinc chromate non setting paint primer conforming to IS specifications including labour for fixing peg stays and handles complete all as per directions and specifications. (Peg stays and handles will be supplied by the department free of cost). , Note: Steel sections should conform to IS 7452-1982 and IS 1028-1983.Steel sections to be adopted for standard windows and ventilators shall be F7D for outer and inner frames weighing 1.419kg/ m and F4B weighing 2.28 kg/m for central mullions as
Page 26 04/25/12

98725

Item No Part : C

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Control room

0023a

G050A

meeting bar for shutters wherever glazing bars, sub-light, side light, partly fixed and partly hung shutters are required. , The steel sections to be adoptedshall be as prescribed in IS 7452-1982. The steel sections should be cut to length, joints mitred and electrically welded, grinded in sub-dividing frames of units shall be tennoned and rivetted into frames 16.000 a) Steel glazed fully openable windows/ventilators with electrically. shutters top hung/ central hung/ side hung With 4mm thick plain glass Providing and laying Indian patent stone flooring with cement concrete 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) using graded granite stone aggregate obtained from approved quarry laid to level or slope in bays not exceeding 3sqm per panel including providing 3mm thick Aluminium dividing strips to the full depth of the flooring and finished smooth, curing, etc; complete all as per specifications.
80.000 a) 40mm thick (Using 20mm nominal size stone

1,554.57 SQM C 1.30

24,873.12

0024

H060

0024a

H060C

240.18 SQM C 15.00

19,214.40

aggregate)
0025 H175

Providing and laying Ceramic tile flooring/dadoing of approved quality, size, colour and thickness according to the dimensions of tiles and having scratch hardness and other parameter conforming to IS 13630 (Bell or Navin or spartek or Jhonson or kajaria or somany or equivalent make) laid over a bed/backing as specified below, , with cement slurry at 3.30kg/sqm, close jointed and pointed with matching white cement slurry mixed with approved pigmement and finishing to required level, curing etc.,complete all as per specification and as directed by Engineer In charge at all floors.
20.000 a) In flooring with approved colour floor tiles ( Regular / 630.57 SQM C 10.14 12,611.40

0025a

H175A

plain or dark colour/ glossy or mat series) size 300mm X 300mm as per IS 13755-1993 over bed/backing of 20mm thick in CM 1:4.
0025b H175B 40.000 b) In dado with approved colour wall tiles ( Regular /

613.78 SQM C 10.14

24,551.20

plain or dark colour/ glossy or mat series) size 300mm X 200mm as per IS 13753-1993 over a bed/backing of 12mm thick in CM 1:3.
0026 H282

Providing and laying vitrified ceramic tile flooring / skirting using approved quality vitrified ceramic tiles of approved size and thickness according to size manufactured by M/s. Johnsons Ceramic / Somani / Khajaria or equivalent make laying the tiles overa bed of 20mm thick cement mortar 1:3 with cement slurry @ 3.3 kg / sqm., jointed and pointed with matching grey / white cement slurry mixed with matching pigement and finishing to required level, curing etc. as per manufacturer's specifications, drawings etc. at all heights for:
140.000 a) Tile size of 600 x 600mm of marble series 1,171.52 SQM C 14.72 1,64,012.80

0026a 0027

H282A T065

Providing and fixing at all heights/ in all floors with all leads Anodised Aluminium doors/ windows/ partitions manufactured from best extruded Aluminium sections confirming to ISI, cut to length,
Page 27 04/25/12

98725

Item No Part : C

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Control room

0027a

T065A

joints mitred and corners grinded with joints water proof the outer frame and shutter frame stiffened with corner angle strips or provided for in the frame for fixing the frame to R.C.C Columns/ masonry on sides, , RCC lintels on top and P.C.C cills or floor at bottom, the frame work fixed with standard approved fastenings all generally as per details shown in drawings and specification with all the sections pretreated for removal of any rust and prevention of further rust formation and coated with greasy materials for non-adherence of mortar orany other sticky materials and , this coat to be removed after installations of the sub-dividing frames by tennoned and rivetted into frames all aluminium surface be thoroughly cleaned free or rust scale or dirt and mill scale by pickling surfaces finished with anodised dull matt finishing 15 MICRON thick including cost of pull and push plates and fixtures for hinged openings (arrangement with steel bearings wherever necessary), cost of labour for fixing of mortice lever locks, aluminium handles, door fittings like tower bolts etc., supplied free for fixing including screws / bolts (Or these materials measured separately elsewhere) where shutters are involved etc., complete ,, cost of providing and fixing of glass of selected glazing quality of thickness and type of glass specified hereinafter or panel boards including nylon or PVC or rubber lining of approved quality wooden grounds, rubber gasket, aluminium glazing clips, mastic etc., and fixing with aluminium glazing clips and alsosnap-on type with holes as per drawing and specifications provided for separately in the sub items following the main items of frame workfor partition and door shutters as below: NOTE: All fitting works shall be carried out as per I.S specifications including necessary rivets, screws, lugs, scaffolding, etc., complete all generally as per drawings. The sizes of the components should confirm 250.000 a) Providing and fixing of Anodised Aluminium (Matt as per details in drawings. finish) frame work (Horizontal and verticals) for partitions Doors /Windows with required sections of JINDAL/ INDAL make or equivalent including allitems and contingencies described above complete (Aluminium beadings and glazing clips measured under this item only)
150.000 b) Providing and fixing of frame work ( Styles and rails)

389.72 KGS

97,430.00

0027b

T065B

390.38 KGS

58,557.00

for Doors shuters/window shutters with required sections of JINDAL/ INDAL make or equivalent including providing all items and hinged / pivoted arrangements for operation of shutters and labour cost for fixing of door fittings and locks ( Which shall be free issues for fixing or paid separately) etc., complete. (Aluminium beadings and glazing clips measured under this item only.)
0027c T065C 60.000 c) Providing and fixing Glass panes of selected glazing 443.26 SQM 26,595.60

quality and thickness as specified below including providing and fixingNylon/rubber/ PVC lining of approved quality and fixing with Aluminium glazing clips/ Aluminium beadings (Supply cost of Aluminium clips/ Aluminium beadings are measured in items above for DOORS / WINDOWS/ PARTITIONS etc., Using 4mm thick plain glass
98725 Page 28 04/25/12

Item No Part : C 0028

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Control room F035

Supplying, fabricating, assembling, hoisting/erecting and fixing in position at all heights and with all leads, structural steel works of welded built-up sections, all as per structural drawings and as per detailed specifications (for materials and workmanship) in the situations described hereinafter including a)cutting of components to required lengths/widths and shapes/profiles, b)smooth machining of edges/faces , , c) welding (electric arc welding) at joints of built-up sections/single sections for required weld lengths and sizes and d) painting all over with two coats of Synthetic enamel paint of approved quality , make and colour/shade over one coat of red oxidezinc chromate primer with surfaces duly prepared to receive painting etc.,complete all as directed by the Engineer-in-charge , NOTE : The Contractor shall submit fabrication shop drawings for work involved based on construction drawings (that may be issued during construction period) for approval by Engineer-in-charge.The fabrication work shall start only after approval to the fabrication drawings. Any change required in the fabrication drawings shall be carried out at no extra cost over the quoted rates., Fabrication shall be in a perfectly workmanship like manner and as provided in Section V and VI of IS 800 and IS 7215. Welding shall be carried out by qualified welders. Electrodes for welding, the procedure, selection, test and inspection shall conform to provisions in IS 816, IS 818, IS 822, and IS 833.Erection/hoisting shall commence only after passing of fabricated parts by the Engineer -in- charge.
0.450 a ) S t r u c t u r a l s t e e l w o r k s o f C A B L E T R E N C H 56,711.22 M.T 25,520.05

0028a

F035E

COVERS/DRAIN COVERS with Chequered MS Plates and welded connection/joints.


0028b F035H 0.125 b) Structural steel works as in item F035 above but 47,588.49 M.T 5,948.56

with MS angles tees and other sections.


0029 N075

Supplying and filling gravel obtained from approved quarry in layers not exceeding 150mm in depth consolidating each layer by ramming with frog rammer, watering and dressing etc; complete including all leads and lifts and all as per specifications.
15.000 a) Under floors/In plinth protection. 280.27 CUM 4,204.05

0029a 0030

N075A H050

0030a

H050A

Providing and laying cement concrete in pavements and ramps in panels not exceeding 10sqm per panel and plinth protection in panels not exceeding 3sqm per panel using graded hard granite stone aggregate including providing necessary formwork, making 10mm wide grooves in panels for depth of 1/3 rd of thickness of pavement or 40mm which ever is more and filling the grooves with approved hot poured sealing compound confirming to grade A or B of IS-1834, consolidation, curing and treatment for the topwith broom finish, etc; complete all as per specifications, Mix ratio specified is for (cement: coarse sand: graded stone aggregate). 11.000 a) Using 20mm nominal size agreegate In CC 1:3:6.

2,769.55 CUM C 320.00

30,465.05

98725

Page 29

04/25/12

Item No Part : C 0031a

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Control room L035A 165.000 Providing and laying angular fillet 7.5x7.5cm cement 9.77 RMT C 0.90 1,612.05

concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate) 20mm nominal size, including compaction, finishing, curing, etc; complete all as per specifications.
0032 K305

Providing plaster drip/ moulding of size as specified below in cement mortar 1:3 (1 cement :3 fine sand) including scafolding ,curing etc, complete all as per specifications ,drawings and direction of Engineer -in -charge.
165.000 a ) 45mmx15mm size 12.43 RMT C 1.50 2,050.95

0032a 0033

K305A J220

Providing and fixing rigid PVC SWR (soil, waste and rain water) drainage / rain water pipe conforming to Type-A IS 13592-1992, including accessories like bends and fixing with pipe clips, adhesive at joints all as per manufacturer's specifications torequired length etc., complete all as per specifications and directions of Engineer in charge.
25.000 a) 160mm dia OD pipes with minimum wall thickness 333.75 RMT C 6.88 8,343.75

0033a

J220C

of 3.20 mm
0034 D050

Extra for mixing water proofing compound of approved quality and brand in R.C.C items with ROFFE HYPROOF manufactured by M/s. Roffe Construction Chemicals Pvt. Ltd. at 140ml per 50kgs of cement or CONPLAST X 421 IC of Fosroc Chemicals ltd. at 130ml per 50 kgs of cement or equivalent approved make mixed with cement as per manufacturer's specifications etc., complete all as per specifications. (Rate to include the cost of water proofing compound).
61.000 a) In M-35 grade concrete 106.85 CUM 6,517.85

0034a 0035

D050E O010

Providing and laying light duty Non-pressure NP-2 Class R.C.C Hume pipes with collars jointed with stiff mixture of C.M. 1:2 (1 cement:2 fine sand) including joints, etc; complete.
24.000 a) 150mm dia 309.07 MTR C 0.60 7,417.68

0035a 0036

O010B B010

Providing and constructing RANDOM RUBBLE MASONRY using hard granite stones obtained from approved quarry with bond stones at every 0.50 sqm of wall surface in cement mortar in mixes stipulated below without pinning on face, but including raking out joints and pointing flush in same mortar including curing, etc; complete as per specifications in FOUNDATION AND PLINTH. (Rate includes cost of bond stones wherever provided). (Mix ratio specified is for cement : coarse sand)
15.000 a) In cement mortar 1:6. 75.000 Providing and fixing of Armstrong Prima Adria 1,701.91 CUM C 82.50 1,159.39 SQM 25,528.65 86,954.25

0036a 0037a

B010A M020A

Microlook Edge Mineral Fibre Ceiling Tile in tru horizontal level false ceiling grid manufactured by M/s. Armstrong World Industries or equivalent using hot dipped galvanized steel section exposed surfacechemically cleaned capping prefinished in baked polyster paint, Armstrong main tee size
98725 Page 30 04/25/12

Item No Part : C

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Control room

30x15mm every 1200mm c/c maximum and rotary stitched 1200mm Armstrong cross tee at every 600mm c/c and 600mm , Armstrong cross tee at every 1200mm c/c maximum and Armstrong wall angle alround the wall to form grid size of 600x600mm and suspending the grid using 2mm pre straightened GI rod / wire and 8mm dia anchor fasteners at every 1200mm intervals at the main tee and laying Armstrong Prima Adria MicrolookEdge Mineral Fibre Ceiling Tiles of size 600mm x 600mm x 15mm , over the formed grid, including providing necessary openings and additional framework required for light fittings, etc., manufactured by Armstrong World Industries having fire rating of60 minutes as per BS 476/23 of 1987, , light reflection of >85%, Noice Reduction Co-efficient (NRC) of 0.50, Sound attenuation of 32db, k=0.052 - 0.067 W/m K, weight of 4.0kg/sqm and Humidity Resistance of 95%. The work shall be executed as per themanufacturers specifications and direction of Engineer in charge.
0038 I185

0038a 0038b 0039 0039a

I185B I185E K135 K135A

Supplying and fixing solid hard core non decorative type(BN) interior grade commercial BLOCK BOARD FLUSH DOOR SHUTTERS of approved make conforming to IS-2202 (part-I) - 1991 with teak wood internal lipping on all sides and solid teak wood inserts formounting locks, etc; having well matched commercial ply veneering with cross bands and face veneers on both faces, including cost of labour for fixing builder's hardware and locking arrangement etc; complete all as per specifications but excluding cost of builder's hardware and locking arrangement issued with screws by the department free of cost. NOTE: Samples as stipulated in IS should be furnished for tests free of cost by the contractor as the tested samples are destroyed during testing. 13.000 a) Single shutter 35 mm thick
4.200 b) Double shutter 35 mm thick

1,354.03 SQM 1,407.08 SQM

17,602.39 5,909.74

50.000 Painting wood work with TWO or more coats of

54.52 SQM

2,726.00

SYNTHETIC ENAMEL PAINT of I quality and approved colour to give an even shade over a coat of synthetic enamel primer including cleaning the surfaces, filling the crevices with approved filler,applying a coat of approved putty on whole surface and rubbing the surface to achive desired smooth surface, scaffolding, etc; complete all as per specifications. (Rate to include cost of synthetic enamel primer, putty also).
0040 0040a K150 K150A 23.000 Painting steel work with TWO or more coats of 66.68 SQM 1,533.64

SYNTHETIC ENAMEL PAINT of I quality and approved colour to give an even shade over a coat of red oxide zinc chromate primer including cleaning the surfaces, applying a coat of approved putty on whole surface and rubbing the surface to achive desired smooth surface, scaffolding, etc; complete all as per specifications ( Rate to include cost of zinc chromate primer, putty also).
98725 Page 31 04/25/12

Item No Part : D

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

PH works ( Internal & external) Total of Part : C 35,28,126.05

98725

Page 32

04/25/12

Item No Part : D 0002

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

PH works ( Internal & external) X020

Providing and Fixing Indian Style Water Closet Suite (Orissa pan) Comprising of : A) Indian water closet white glazed vitreous chinaware Orissapan of approved make of size 580X440mm with trap as mentioned below conforming to IS:2556 part-IIIbearing ISI mark fixed to floor including cutting and making good the walls and floors etc. , B) 10 ltrs capacity approved quality and make polymer high level flushing cistern with all internal fittings conforming to IS fixed to wall with necessary brackets, screws and plugs. C) 32mm n.b. PVC flush pipe of heavy quality of required length with necessary check nuts from the cistern to the WC inlet and making necessary connections, concealed in the wall, etc. D) 15mm size heavy quality flexible PVC inlet pipe connection with CP brass check nuts with washers at both ends E) 15mm n.b. CP brass angle-cock/stop cock conforming to IS:781 of approved make with a minimum weight of 400gms on the inlet to the cistern. , F) 15mm n.b. medium quality GI overflow pipe with specials from the cistern to 15cms above the floor, concealed in wall terminated with CP brass mosquito proof jali. Complete all as specified above with approved fittings. (Refer fig. No. CED:PH:1.2 of specifications for PHEngg works).
2.000 a) With 'S' trap 2,685.99 EACH C 5.00 5,371.98

0002a 0003

X020A X050

0003a 0004a

X050A X065A

Providing and Fixing Indian make wash hand basin (with CP bottle trap) Comprising of : A) Best Indian make white glazed vitreous chinaware wash hand basin of approved make of size mentioned below conforming to IS:2556 Part-IV with single taphole and bearing ISI mark supported on a pair of painted CI brackets conforming to IS:775 B) One 15mm CP brass pillar cock of approved make with hot or cold water indication as required conforming to IS:1795 with minimum weight of 577gms. C) One 15mm heavy quality flexible PVC inlet pipe connection with CP brass hexagonal check nuts with, washer at both ends. D) One 15mm CP brass angle-cock/stop cock of approved make conforming to IS:781 of approved make with a minimum weight of 400gms onthe inlet to the basin. E) One 32mm heavy quality CP brass waste coupling with rubber plug and CP chain , F) One 32mm heavy quality CP brass bottle trap with extension piece and wall flange. G) One 32mm medium quality GI waste pipe with specials from extension piece of the bottle trap to the floor trap, length not exceeding 1 mtr concealed in wall. H) One no. 40mm GI bend and 40mm dia 250mm long GI pipe connection waste pipe to floor trap. All as per specifications and as directed withapproved fittings. (Refer fig. No. CED:PH:1.4 of specifications for PH 2.000 Engg works). 400 mm a) Size 550 X
2.000 Providing and Fixing in position large urinal comprising

2,174.47 EACH C 1.50 2,945.10 EACH C 1.00

4,348.94 5,890.20

of : A) White glazed vitreous chinaware of approved makelarge urinal of size 600X400X375mm with necessary fixtures conforming to IS : 2556 Part-VI bearing ISI mark. B) 15mm n.b.CP brass concealed stop cock of approved make conforming to IS:781 on flushing
98725 Page 33

04/25/12

Item No Part : D

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

PH works ( Internal & external)

line one for each urinal in the range. , C) CP brass distribution pipe and spreader of best approved quality to the urinal with necessary CP brass specials, clamps etc., onefor each urinal in a range. D) One number 32mm CP brass waste coupling-one for each urinal E) One number 32mm PVC waste pipe and specials from each urinal to floor trap / half round channel. Complete all as specified with approved fittings.
0005a X105A 3.000 Providing and Fixing in position best Indian make 978.94 EACH C 2.00 2,936.82

Marble partition slab for urinals, size 610X1150mm, 20mm thick (tolerance + \ - 1mm) polished on both sides and machine cut edges with exposed corners rounded etc all as specified and directed.(Ref. Fig.No.CED:PH1.5 of PH Engg. Specification)
0006a X110A 2.000 Providing and Fixing in position best quality approved

504.08 EACH

1,008.16

make Mirror of size 550X400mm mounted on 6mm thick plain asbestos sheet backing with 4no.s of CP brass cap screws and washers fixed to walls with necessary plugs etc. all specified and directed. (Ref. Fig.No.CED:PH1.4 of PH Engg. Specification)
0007a X125A 5.000 Providing and Fixing in position approved make 15mm 196.29 EACH 981.45

n.b.CP brass screw down bib tap conforming to IS:781 with a minimum weight of 400gms
0008 X130

Providing and Fixing in position best quality approved make liquid soap holder as mentioned below with CP brass brackets, CP cap screws, washers etc, fixed to wall with necessary plugs etc. all as specified and directed. (Ref. Fig.No.CED:PH1.4of PH Engg. Specification)
2.000 a) With plastic container 144.26 EACH 288.52

0008a 0009

X130C X150

Providing and Fixing in position best approved quality 15mm CP brass shower of approved make.
1.000 a) Swivel type with shower arm and Wall flange 319.14 EACH 319.14

0009a 0010

X150B X155

Providing and Fixing in position approved best Indian make heavy quality screw down Gun metal Gate valve with hand wheel of following sizes conforming to IS:778 and bearing ISI mark including testing, making good the leakages etc. complete.
2.000 a) 20mm n.b. 2.000 b) 50mm n.b. 519.12 EACH 2,343.10 EACH 1,038.24 4,686.20

0010a 0010b 0011

X155B X155F X165

Providing and Fixing in position high pressure best quality gun metal ball valves with polythene float conforming to IS:1703 and , bearing ISI mark of size mentioned below including testing, making good the leakages etc., all as specified and directed.
1.000 a) 20mm 452.96 EACH 452.96

0011a 0012

X165B X170

Providing, laying, jointing, fixing, testing, painting, commissioning GI pipes, medium grade conforming to IS:1239 with a minimum weight as follows including GI specials, , cutting the pipes to the
Page 34 04/25/12

98725

Item No Part : D

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

PH works ( Internal & external)

0012c 0013

X170O X175

required lengths, threading, jointing the pipes, chasing the walls and floors, making the holes, clamping to walls using wooden spacers or clamps and restoring the same to the original conditions, necessary excavation, testing, refilling etc. Complete all specified and directed. (Ref. Fig. No.CED: PH2.1 of PH Engg. Specification) 30.000 a) For external works - 50mm n.b. (5.17 kg/mtr) Providing, laying, jointing, fixing, testing,commissioning threaded PVC pipes schedule 40 conforming to ASTM-D-1785 with GI specials, cutting the pipes to the required lengths, threading, jointing the pipes , using teflon tape chasing the walls and floors, making the holes, clamping to walls using the wooden spacers or clamps and restoring the same to the original conditions, necessary excavation, testing, refilling etc. Complete all as specified and directed and as per manufacturer's specification.
150.000 a) For External works - 50mm n.b. 10.000 b) For Internal works - 20mm n.b. 85.000 c) For Internal works - 25mm n.b. 7.000 Providing and fixing UPVC floor trap with 75mm dia

263.66 MTR

7,909.80

0013a 0013b 0013c 0014a

X175N X175B X175C X185A

156.74 MTR C 0.50 76.73 MTR C 1.00 103.87 MTR C 1.00 282.58 EACH C 6.00

23,511.00 767.30 8,828.95 1,978.06

outlet "Supreme" or other equivalent approved make, including connection with PVC soil / waste pipe, necessary 150mm thick CC 1:2:4 for embedding the trap including providing and fixing top rail and strainer on top of the trap etc. complete all as specified and directed.
0015 X195

Laying and Fixing in position under floor against wall in chases sand cast Iron soil pipes and specials conforming to IS:1729 includinng cutting the pipes to the required lengths, necessary excavation, chasing of walls/floors, testing, painting etc. (Specials at junction of lateral pipe and and vertical stack must have access door for inspection) (Ref. Fig.No.CED:PH 3.1 of PH Engg. Specification) Note: Cost of pipes and specials will be paid separately elsewhere as an Item.
25.000 a) 50mm Dia 10.000 b) 75mm Dia 17.70 MTR 22.86 MTR 442.50 228.60

0015a 0015b 0016

X195A X195B X210

Providing and Laying best quality salt glazed stoneware pipe of grade A and specials conforming to IS:651 in trenches for all depths to correct grade, level and alignment including jointing with hemp yarn and cement mortar 1:1 including testing, making good the leakages all as specified and directed. (Ref. Fig.No.CED:PH 8.1 & 8.2 of PH Engg. Specification)
15.000 a) 100mm Dia 30.000 b) 150mm Dia 2.000 Construction of valve chamber of size Page 35 116.84 MTR C 1.67 176.69 MTR C 2.50 4,399.19 EACH C 166.00 04/25/12 1,752.60 5,300.70 8,798.38

0016a 0016b 0018a 98725

X210A X210B Y050B

Item No Part : D

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

PH works ( Internal & external)

0019a

Z005A

600X600mm, 750mm deep comprising of 230mm thick brick walls using first class country brick walls in CM 1:5 over a bed of 150mm thick PCC 1:4:8 (using 40mm size metal) with 75mm projections alround beyondthe masonry faces, plastered with CM 1:3, mixed with waterproofing compound as per manufacturer's specifications 12mm thick on internal, external top surfaces and internal and top exposed surfaces finished smooth with a floating coat of neat cement,, providing and fixing painted light duty double seal CI frame and cover of size 600X450mm weighing not less than 52Kgs conforming to IS 1726 with locking arrangement fixing the frame in RCC1:2:4 including cost of necesary , steel reinforcement, fabricating, form work, curing, etc, complete all as specified and directed. Note: CC 1:2:4 in the above Item is by using 20mm graded granite aggregate obtained 2.000 Providing and Fixing in position best quality salt glazed stoneware gully trap of size 100mm square with 100mm outlet; conforming to IS:651 embedded in plain cement concrete 1:4:8 (20mm Metal), providing and fixing 100mm square CI grating on top of the trap, all the above encased in a chamber of 300X300mm built with 115mm thick brick masonry using first class country bricks in CM 1:3, over a bed of CC 1:4:8 using , 40mm size metal 100mm thick, plastering with CM 1:3, 13mm thick inside, outside, exposed top surfaces and Internal and top exposed surfaces finished smooth with a floating coat of neat cement, Providing and fixing CI frame and cover of size 300X300mm weighing not less than 7Kgs fixing the frame in PCC 1:2:4 using 20mm stone metal including painting the frame and cover with 3-coats of anticorrosive black bitumastic painting etc. Complete all as specified and directed. Construction of Inspection chamber of internal clear dimensions as mentioned below in 230mm thick brick masonry using first class country brick walls in CM 1:3 over a bed of 150mm thick 1:2:4(20mm metal) cement concrete, plastering with CM 1:2, 12mm thick on internal, external, top surfaces and internal and exposed top surfaces finished smooth with a floating coat of neat cement, Plain cement concrete 1:2:4 for , benching, channeling, providing and fixing light single seal CI frame and cover as mentioned below conforming to IS 1726, CC 1:2:4 for fixing the RCC frame and cover, painted with 3-coats of anticorrosive black bitumastic paint, encasing sewers connection to chamber in CC 1:2:4 etc. Complete all as specified and directed.(Ref. Fig.No.CED:PH8.6 of PH Engg. Specification) Note: CC 1:2:4 in the above Item is by using 20mm graded granite aggregate obtained from approved quarry.
2.000 a) 450X450X450mm with RCC frame and cover of

1,253.02 EACH C 57.00

2,506.04

0020

Z015

0020a

Z015A

2,719.84 EACH C 175.00 4,030.33 EACH C 252.00 4,377.11 EACH C 274.00

5,439.68

size 450X450mm
0020b Z015B 2.000 b) 600X600X600mm with RCC frame and cover of

8,060.66

size 610X450mm
0020c Z015C 1.000 c) 600X600X750mm with RCC frame and cover of

4,377.11

size 610X450mm
98725 Page 36

04/25/12

Item No Part : D 0021a

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

PH works ( Internal & external) Z070A 10.000 P r o v i d i n g d i s p e r s i o n t r e n c h o f w i d t h 1 m t r a n d 653.61 MTR 6,536.10

0022a

Z035A

necessary depth with open jointed stoneware pipes of 100mm dia with specials, filtering media, bamboo matting etc as follows: (A) Earth excavation in the strata met with for trenches of 1m width and required depth including dewatering subsoil and rain water to keep the area of excavation dry, , shoring and strutting wherever necessary, trimming bottom and levelling to correct grade and alignment and backfilling trenches with selected excavated material up to a lead of 50mtr as specified and directed, supplying and dry filling granite stone metal of 20mm maximum size including depositing neatly in layers and level to width of 1mtr and depth of 0.45mtr as directed. , (B) Stoneware glazedpipes and specials of 100mm dia such as tees, bends etc. as per IS:651 and laying in loose joints without any jointing materials, sockets facing down the gradient with a slope of 1 in 300, open joints held in place by suitable stone wedges to properline and lavel etc. Complete all as specified and directed. (C) Supplying and dry filling of granite stone metal 12mm average size including depositing neatly in layers and levels of dimensions 1mX0.15m for filter beds as specified and directed., (D) Supply and Laying in position two layers of bamboo matting with surface treated with bitumen and joints staggered on filter bed all as directed and specified. (E) Supply and Laying of 1 layers of 1000gauge (250 microns) thick LDPE film conforming to IS:2508-1977 over the bamboo matting all as specified and directed. 2.000 Construction of Manhole of internal clear dimensions 800X800mm in 230mm thick brick masonry using first class country bricks in CM 1:3 over a bed of 150mm thick CC1:2:4, plastering with CM 1:2, 12mm thick both on internal, and external surfaces and Internal, exposed top surfaces finished smooth with a floating coat of neat cement, PCC 1:2:4 for benching, channeling, providing and fixing precast RCC M-15 frame and cover of size 600X600mm including the cost of necessary steel reinforcement as per drawing, CI steps with 3-coats of anticorrosive, black bitumastic painting, encasing of sewer connections to manholes with PCC 1:2:4 etc. , Complete all as specified and directed for initial depth of 0.75m (Ref. Fig.No.CED:PH 8.7 of PHEngg. Specification) Note: CC 1:2:4 in the above Item is by using 20mm graded granite aggregate obtained from approved quarry.
2.000 Supply and fixing of HDPE (sintex tank) with 1000 ltr

6,142.64 EACH C 469.00

12,285.28

0024

Z582

8,489.25 EACH

16,978.50

capacity tank ISI approved brand.


Total of Part : D 1,43,023.87

98725

Page 37

04/25/12

Item No Part : E 0001a

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Septic Tank A005A

Earth work in Excavation over AREAS (exceeding 30 cms in depth, 1.50 mtr width as well as 10 sqm on plan) in ALL KINDS OF SOIL upto a depth not exceeding 1.50 mtr including disposal of excavated earth, lead upto 50 mtrs and lift upto 1.50 mtr etc., complete all as per specifications. (Disposed earth to be levelled by breaking clods if any and neatly dressed).
30.000 a) upto 1.50m below GL 11.000 b) 1.50m to 3.0m below GL 112.67 CUM 123.93 CUM 3,380.10 1,363.23

0001aa 0001ab 0002

A005AA A005AB C010

Providing and laying cement concrete using 40mm nominal size graded hard granite stone aggregate obtained from approved quarry including compaction, finishing top surface to level, curing but excluding cost of formwork, etc; complete as per specifications. Mix ratio specified is for (cement: coarse sand: graded stone aggregate).
2.000 a) In foundation and plinth/sub-base to floors with 2,030.32 CUM C 130.00 4,060.64

0002a

C010B

P.C.C 1:4:8
0003 E030

Providing rigid and water tight centering and shuttering using best quality wood/ plywood/ steel forms and centering with steel props, acro tubes etc., includingstrutting, propping, bracing, staging etc., compplete for all RCC items fixedin positionas required including labour for careful removal of form work etc., complete all as per specifications at all heights. In Horizontal / Vertical/ slanting surfaces.
30.000 a) Foundations, Footings, Bases of columns, Mass 63.19 SQM 1,895.70

0003a

E030A

concreting, Floorings etc.


0003b E030D 54.000 b) Walls (any thickness) including attached pilasters, 117.94 SQM 6,368.76

buttresses plinth and string courses etc.


0003c E030C 34.000 c) suspended floors, roofs, Balconies and access 134.62 SQM 4,577.08

platforms.
0004 D033

98725

Providing & laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, using graded hard granite stone aggregates of maximum 20mm nominal (down graded) size obtained from approved quarry including fine aggregates conforming to latest IS 383 and cement all as per approved design mix proportions conforming to latest IS 10262 with minimum cement content for durability including supplying and providing concrete cover blocks etc., which shall be followed as per latest IS456-2000 including mixing, transporting, placing, vibrating, compaction, finishing to required levels, curing etc.,complete all as per specifications but excluding cost of formwork and steel reinforcement. Rate to include labour for keeping embedments if any wherever required while casting. Rate also to include lift charges and scaffolding for all heights, depths, levels from FFL / GL. (The design mix proportions shall clearly indicate cement :fine aggregate : coarse aggregate : water cement ratio and approval shall be obtained from Engineer-inPage 38

04/25/12

Item No Part : E

SOR Code

Quantity

Description of Item

Estimate rate

Unit

Amount

Septic Tank

0004a

D033A

charge for initial and subsequent mixes as and when there will be change in quarry / materials for M-35 grade reinforced cement concrete, etc. all works above plinth level at all heights. 6.500 a) Walls ( any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc.,

4,340.01 CUM C 380.00

28,210.07

0004b

D033B

6.500 b) Beams, suspended floors, roofs having slope upto

4,492.82 CUM C 380.00

29,203.33

15 degree, landings, balconies, shelves, chajja, lintels, bands, plain window sills, staircases and spiral stair cases etc.,
0005 C022

Providing and laying cement concrete using 20mm nominal size graded hard granite stone aggregate obtained from approved quarry including compaction, finishing top surface to level, curing but excluding cost of formwork, etc; complete all as per specifications. Mix ratio specified is for (cement: coarse sand: graded stone aggregate) In walls (any thickness), retaining walls, return walls including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacingcourses, parapets upto floor-V level, WITH:
2.500 a) P.C.C 1:3:6 2,618.03 CUM C 220.00 6,545.08

0005a 0006

C022D D050

Extra for mixing water proofing compound of approved quality and brand in R.C.C items with ROFFE HYPROOF manufactured by M/s. Roffe Construction Chemicals Pvt. Ltd. at 140ml per 50kgs of cement or CONPLAST X 421 IC of Fosroc Chemicals ltd. at 130ml per 50 kgs of cement or equivalent approved make mixed with cement as per manufacturer's specifications etc., complete all as per specifications. (Rate to include the cost of water proofing compound).
13.000 a) In M-35 grade concrete 106.85 CUM 1,389.05

0006a 0007

D050E K040

Water proof cement plastering of thickness as specified below in cement mortar 1:3 (1 cement : 3 coarse sand) mixed with approved water proofing compound such as CICO or ACCOPROOF or equivalent as per manufacturers specifications including scaffolding, curing, etc; complete for EXTERNAL SURFACES all as per specifications UPTO 10 MTR LEVEL ABOVE G.L.
120.000 a) 15mm thick 5.000 Providing and fixing 75mm dia (O.D) Unplasticised 91.44 SQM C 8.57 135.77 RMT 10,972.80 678.85

0007a 0008a

K040C J185A

PVC pipe with vent cowl water spouts conforming to IS 4985-1988 inclusive of specials (Tee) confirming to IS 7834 (part-IV)-1987 of working pressure 6kg/sqcm.
0009a N020A 5.000 Supplying 22.4mm to 53mm IRC graded granite stone 883.16 CUM 4,415.80

metal obtained from approved quarry at site of work for pre-measurement including stacking as directed complete all as per specifications.
Total of Part : E 98725 Page 39 1,03,060.49 04/25/12

Grand total : Rs.

1,99,01,945.31

Name of Work Construction of 300 gallon Vertical Mixer Building no.4 at SPROB. List of Similar Items Part sno No quantity unit (Refer Clause no 39) Brief detail
Clearing Jungle including uprooting of rank vegetation, grass, brush wood, trees and sapplings of girth up to 30 cm measured at a height of 1 m above ...

A C

0001 0001

10,000.000 1,000.000 11,000.000

SQM SQM

2.18 2.18

A C

0002a 0002a

25.000 15.000 40.000

EACH EACH

Felling trees of the following girth (measured at a height of 1 M above ground level) including cutt... a) Felling Trees-beyond 30cm upto including 60cm girth....

66.34 66.34

A C

0002b 0002b

10.000 10.000 20.000

EACH EACH

Felling trees of the following girth (measured at a height of 1 M above ground level) including cutt... b) Felling Trees-beyond 60cm up to including 120cm girth....

292.70 292.70

... Providing and injecting Chemical emulsion for PRE-CONSTRUCTIONAL Anti-termite treatement and creatin...

A C

0003a 0003a

527.000 230.000 757.000

SQM SQM

118.91 118.91

... Earth work in Excavation over AREAS (exceeding 30 cms in depth, 1... a) upto 1.50m below GL...

A B E

0043aa 75.000 0001aa 320.000 0001aa 30.000 425.000

CUM CUM CUM

130.13 130.13 112.67

... Earth work in Excavation over AREAS (exceeding 30 cms in depth, 1... b) 1.50m to 3.0m below GL...

A E

0043ab 100.000 0001ab 11.000 111.000

CUM CUM

143.14 123.93

... Earthwork in excavation for FOUNDATION TRENCHES in ALL KINDS OF S... Upto 1.5m below G.L....

A C

0004aa 620.000 0004aa 170.000 790.000

CUM CUM

132.18 115.22

... Filling available excavated approved earth (excluding rock) in trenches, sides of foundations, plint...

A C

0006a 0011a

450.000 150.000 600.000

CUM CUM

37.11 37.11

98725

Page No:

41

Signature of Tenderer

List of Similar Items Part sno No quantity unit

(Refer Clause no 39) Brief detail

A B C

0032a 0010a 0036a

34.000 144.000 15.000 193.000

CUM CUM CUM

Providing and constructing RANDOM RUBBLE MASONRY using hard granite stones obtained from approved qu... a) In cement mortar 1:6....

1,701.91 1,701.91 1,701.91

A C

0007a 0008a

65.000 5.000 70.000

CUM CUM

Providing and constructing BRICK MASONRY in cement mortar as per mixes stipulated below using approv... a) USING BRICKS OF CLASS DESIGNATION "4.5"(Minimum Average Compressive strength not less than 4.

1,997.10 1,997.10

A C

0008a 0009a

330.000 50.000 380.000

CUM CUM

Providing and constructing BRICK MASONRY in cement mortar as per mixes stipulated below using approv... a) USING BRICKS OF CLASS DESIGNATION "4.5"(Minimum Average Compressive strength not less than 4

2,255.65 2,255.65

A C

0046a 0010a

40.000 150.000 190.000

SQM SQM

Providing and constructing HALF BRICK MASONRY walls/partitions in the following mixes using FIRST CL... a) USING BRICKS OF "CLASS DESIGNATION 4.5"(Minimum Average Compressive strength not less than 4.

324.59 324.59

Providing and laying cement concrete using 40mm nominal size graded hard granite stone aggregate obt... a) In foundation and plinth/sub-base to floors with P.C.C 1:5:10...

A B C

0005a 0002a 0005a

74.000 52.000 57.000 183.000

CUM CUM CUM

1,844.35 1,844.35 1,844.35

A C E

0011b 0007b 0004a

235.000 10.000 6.500 251.500

CUM CUM CUM

Providing & laying in position machine batched, machine mixed and machine vibrated design mix cement... b) Walls ( any thickness) including attached pilasters, buttresses, plinth and string courses, f

4,340.01 4,340.01 4,340.01

A C E

0011c 0007c 0004b

270.000 71.000 6.500 347.500

CUM CUM CUM

Providing & laying in position machine batched, machine mixed and machine vibrated design mix cement... c) Beams, suspended floors, roofs having slope upto 15 degree, landings, balconies, shelves, cha

4,492.82 4,492.82 4,492.82

98725

Page No:

42

Signature of Tenderer

List of Similar Items Part sno No quantity unit

(Refer Clause no 39) Brief detail

A C

0011a 0007a

357.000 80.000 437.000

CUM CUM

Providing & laying in position machine batched, machine mixed and machine vibrated design mix cement... a) All concrete elements upto plinth level....

4,164.20 4,164.20

A C E

0031a 0034a 0006a

65.000 61.000 13.000 139.000

CUM CUM CUM

Extra for mixing water proofing compound of approved quality and brand in R.C.C items with ROFFE HYP... a) In M-35 grade concrete...

106.85 106.85 106.85

A B C E

0009a 0003a 0006a 0003a

380.000 67.000 208.000 30.000 685.000

SQM SQM SQM SQM

Providing rigid and water tight centering and shuttering using best quality wood/ plywood/ steel for... a) Foundations, Footings, Bases of columns, Mass concreting, Floorings etc....

63.19 63.19 63.19 63.19

Providing rigid and water tight centering and shuttering using best quality wood/ plywood/ steel for... b) Lintels, Beams, Plinth Beams, Girders, Bressumers and cantilevers....

A C

0009b 0006b

954.000 350.000 1,304.000

SQM SQM

103.51 103.51

A C E

0009c 0006c 0003c

1,090.000 290.000 34.000 1,414.000

SQM SQM SQM

Providing rigid and water tight centering and shuttering using best quality wood/ plywood/ steel for... c) suspended floors, roofs, Balconies and access platforms....

134.62 134.62 134.62

A C E

0009d 0006e 0003b

915.000 85.000 54.000 1,054.000

SQM SQM SQM

Providing rigid and water tight centering and shuttering using best quality wood/ plywood/ steel for... b) Walls (any thickness) including attached pilasters, buttresses plinth and string courses etc.

117.94 117.94 117.94

A C

0009e 0006d

853.000 120.000 973.000

SQM SQM

Providing rigid and water tight centering and shuttering using best quality wood/ plywood/ steel for... d) Columns, Pillars, Abutments, posts and struts....

164.69 164.69

98725

Page No:

43

Signature of Tenderer

List of Similar Items Part sno No quantity unit

(Refer Clause no 39) Brief detail

A C

0010a 0016a

130.000 30.000 160.000

M.T M.T

Steel reinforcement for all R.C.C items including decoiling, cutting, hooking, bending, cranking, fa... a) With high yield strength deformed bars....

44,561.16 44,561.16

A C

0035e 0028a

2.500 0.450 2.950

M.T M.T

Supplying, fabricating, assembling, hoisting/erecting and fixing in position at all heights and with... e) Structural steel works of CABLE TRENCH COVERS/DRAIN COVERS with Chequered MS Plates and welde

56,711.22 56,711.22

A C

0035c 0028b

1.500 0.125 1.625

M.T M.T

Supplying, fabricating, assembling, hoisting/erecting and fixing in position at all heights and with... c) Structural steel works as in item above but with MS angles tees and other sections....

47,588.49 47,588.49

A C

0034a 0030a

7.000 11.000 18.000

CUM CUM

Providing and laying cement concrete in pavements and ramps in panels not exceeding 10sqm per panel ... a) Using 20mm nominal size agreegate In CC 1:3:6....

2,769.55 2,769.55

A C

0017a 0024a

315.000 80.000 395.000

SQM SQM

Providing and laying Indian patent stone flooring with cement concrete 1:2:4 (1cement: 2 coarse sand... a) 40mm thick (Using 20mm nominal size stone aggregate)...

240.18 240.18

... Providing and fixing 75mm dia (O.D) Unplasticised PVC pipe water spouts conforming to IS 4985-1988 i...

B E

0011a 0008a

65.000 5.000 70.000

RMT RMT

135.77 135.77

... Providing and laying water proofing treatment over RCC roof in 3 courses, as specified below, after ...

A C

0037a 0015a

90.000 280.000 370.000

SQM SQM

346.91 346.91

A C

0030a 0033a

130.000 25.000 155.000

RMT RMT

Providing and fixing rigid PVC SWR (soil, waste and rain water) drainage / rain water pipe conformin... c) 160mm dia OD pipes with minimum wall thickness of 3.20 mm...

333.75 333.75

A C

0019a 0012b

2,382.000 425.000 2,807.000

SQM SQM

Plastering 12mm thick with cement mortar specified below, finished smooth including scaffolding, cu... a) With C.M 1:4....

71.93 71.93

98725

Page No:

44

Signature of Tenderer

List of Similar Items Part sno No quantity unit

(Refer Clause no 39) Brief detail

A C

0020a 0013a

1,775.000 50.000 1,825.000

SQM SQM

Plastering 15mm thick with cement mortar specified below, finished smooth including scaffolding, cur... a) With C.M. 1:5...

77.86 77.86

... Painting steel work with TWO or more coats of SYNTHETIC ENAMEL PAINT of I quality and approved colou...

A C

0026a 0040a

80.000 23.000 103.000

SQM SQM

57.73 66.68

... Painting internal plastered surfaces with two or more coats of super acrylic emulsion paint of appro...

A C

0024a 0019a

3,047.000 625.000 3,672.000

SQM SQM

48.75 48.75

... Painting external plastered surfaces with two or more coats of 100% acrylic exterior emulsion paint ...

A C

0025a 0018a

2,575.000 316.000 2,891.000

SQM SQM

55.30 55.30

A C

0029a 0032a

180.000 165.000 345.000

RMT RMT

Providing plaster drip/ moulding of size as specified below in cement mortar 1:3 (1 cement :3 fine s... a ) 45mmx15mm size...

12.43 12.43

... Providing and laying angular fillet 7.5x7.5cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 grad...

A C

0028a 0031a

180.000 165.000 345.000

RMT RMT

9.77 9.77

A C

0033a 0029a

73.000 15.000 88.000

CUM CUM

Supplying and filling gravel obtained from approved quarry in layers not exceeding 150mm in depth co... a) Under floors/In plinth protection....

280.27 280.27

Providing and laying light duty Non-pressure NP-2 Class R.C.C Hume pipes with collars jointed with s... a) 150mm dia...

A C

0027a 0035a

50.000 24.000 74.000

MTR MTR

267.59 309.07

A C

0015a 0027a

150.000 250.000 400.000

KGS KGS

Providing and fixing at all heights/ in all floors with all leads Anodised Aluminium doors/ windows/... a) Providing and fixing of Anodised Aluminium (Matt finish) frame work (Horizontal and verticals

389.72 389.72

98725

Page No:

45

Signature of Tenderer

List of Similar Items Part sno No quantity unit

(Refer Clause no 39) Brief detail

A C

0015b 0027b

100.000 150.000 250.000

KGS KGS

Providing and fixing at all heights/ in all floors with all leads Anodised Aluminium doors/ windows/... b) Providing and fixing of frame work ( Styles and rails) for Doors shuters/window shutters with

390.38 390.38

A C

0015c 0027c

10.000 60.000 70.000

SQM SQM

Providing and fixing at all heights/ in all floors with all leads Anodised Aluminium doors/ windows/... c) Providing and fixing Glass panes of selected glazing quality and thickness as specified below

443.26 443.26

98725

Page No:

46

Signature of Tenderer

Name of Work : Construction of 300 gallon Vertical Mixer Building no.4 at SPROB.

CEMENT REQUIREMENT Item No SOR Code Quantity Mixer building Providing and laying cement concrete using 40mm nominal size graded hard granite stone aggregate 74.000In foundation and plinth/sub-base to floors with P.C.C 1:5:10 32.000In foundation and plinth/sub-base to floors with P.C.C 1:3:6 Providing and constructing BRICK MASONRY in cement mortar as per mixes stipulated below using 65.000USING BRICKS OF CLASS DESIGNATION "4.5"(Minimum Average Compressive strength not less than 4.50 Providing and constructing BRICK MASONRY in cement mortar as per mixes stipulated below using 330.000USING BRICKS OF CLASS DESIGNATION "4.5"(Minimum Average Compressive strength not less than 4.5 Providing & laying in position machine batched, machine mixed and machine vibrated design mix 357.000 Description Coefficient Unit Theoretical consumption

Part : A 0005 0005a 0005b 0007 0007a 0008 0008a 0011 0011a 0011b 0011c 0012 0012a 0013 0013a 0014 0014a 0016a 0017 0017a 0019 0019a 0020 0020a 0020b 0021 0021a 0022 0022a 0027 0027a 0027b 0027c 0028a 0029 C010 C010A C010C B050 B050F B060 B060F D033 D033C D033A D033B G080 G080A G100 G100B G115 G115A H225A H060 H060C K005 K005C K015 K015B K015C K025 K025B K040 K040A O010 O010B O010E O010D L035A K305

130.00 220.00

CUM CUM

9,620.00 7,040.00

62.50

CUM

4,062.50

62.50

CUM

20,625.00

380.00 235.000Walls ( any thickness) including attached pilasters, buttresses, 380.00


plinth and string courses, 270.000Beams, suspended floors, roofs having slope upto 15 degree, landings, balconies, shelves, chajja, Providing and fixing steel door system made out of standard rolled steel sections. The door frame, 450.000Fully openable (single/double) shutter and Using MS sheet coverd on single or both sides. Providing and fixing hollow metal pressed steel window system using 60 x 40 x 1.25mm edge folded 40.000Steel fully glazed partly openable and partly fixedwindow/ ventilators with shutters top hung/ Providing and fixing hollow metal pressed steel lovered ventilators using 60 x 40 x 1.25mm edge 15.000Steel fully glazed louverd ventilator with MS channel louver holders With 4 mm thk pin headed 292.000Providing and laying (carborundum based) 40mm thick hardonite non-metallic monolithic flooring Providing and laying Indian patent stone flooring with cement concrete 1:2:4 (1cement: 2 coarse 315.00040mm thick (Using 20mm nominal size stone aggregate) Plastering 12mm thick with cement mortar specified below, finished smooth with lime neeru, including 2,382.000c) With C.M 1:4. Plastering 15mm thick with cement mortar specified below, finished smooth with lime neeru including 1,775.000b) With C.M. 1:5 500.000c) With C.M. 1:4 Plastering 20mm thick with cement mortar specified below finished smooth with lime neeru including 2,300.000b) With C.M. 1:5. Water proof cement plastering of thickness as specified below in cement mortar 1:3 (1 cement : 3 613.000a) 20mm thick Providing and laying light duty Non-pressure NP-2 Class R.C.C Hume pipes with collars jointed with 50.000b) 150mm dia 30.000e) 450mm dia 20.000d) 300mm dia 180.000Providing and laying angular fillet 7.5x7.5cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 Providing plaster drip/ moulding of size as specified below Page 47

CUM CUM CUM

1,35,660.00 89,300.00 1,02,600.00

380.00

0.38

KGS

171.00

10.00

SQM

400.00

7.00 17.90

SQM SQM

105.00 5,226.80

15.00

SQM

4,725.00

5.47

SQM

13,029.54

5.33 6.54

SQM SQM

9,460.75 3,270.00

6.94

SQM

15,962.00

11.42

SQM

7,000.46

0.60 2.40 1.10 0.90

MTR MTR MTR RMT

30.00 72.00 22.00 162.00

Noticeno 98725

04/25/12

CEMENT REQUIREMENT Item No SOR Code Quantity Mixer building in cement mortar 1:3 (1 cement :3 0029a 0030 0030a 0032 0032a 0034 0034a 0037 0037a 0039 0039a 0039b 0044 0044a 0045 0045a 0046 0046a K305A J220 J220C B010 B010A H050 H050A J200 J200A D037 D037A D037B K020 K020C C020 C020A B090 B090D 90.000Providing and laying water proofing treatment over RCC roof in 3 courses, as specified below, after Providing and fixing M-35 grade Precast Reinforced cement concrete using graded hard Granite stone 7.000for cable trench cover slabs etc., 3.000 Plastering 15mm thick with cement mortar specified below finished rough including scaffolding, 275.000c) With C.M. 1:4 Providing and laying cement concrete using 20mm nominal size graded hard granite stone aggregate 10.000In foundation and plinth/sub-base to floors with P.C.C. 1:3:6 Providing and constructing HALF BRICK MASONRY walls/partitions in the following mixes using 40.000USING BRICKS OF "CLASS DESIGNATION 4.5"(Minimum Average Compressive strength not less than 4.5 7.000Using 20mm nominal size agreegate In CC 1:3:6. 180.000a ) 45mmx15mm size Providing and fixing rigid PVC SWR (soil, waste and rain water) drainage / rain water pipe 130.000c) 160mm dia OD pipes with minimum wall thickness of 3.20 mm Providing and constructing RANDOM RUBBLE MASONRY using hard granite stones obtained from approved 34.000In cement mortar 1:6. Description Coefficient Unit Theoretical consumption

Part : A

1.50

RMT

270.00

6.88

RMT

894.40

82.50 320.00 23.43

CUM

2,805.00

CUM

2,240.00

SQM

2,108.70

382.00 390.00

CUM CUM

2,674.00 1,170.00

6.54

SQM

1,798.50

220.00

CUM

2,200.00

12.60

SQM

504.00 4,45,208.65

Total of Part : A Part : B 0002 0002a 0004 0004a 0005 0005a 0006 0006a 0007 0007a 0010 0010a C010 C010A B020 B020A K060 K060A C045 C045A K020 K020A B010 B010A Earthern Merlon Providing and laying cement concrete using 40mm nominal size graded hard granite stone aggregate 52.000In foundation and plinth/sub-base to floors with P.C.C 1:5:10 Providing and constructing RANDOM RUBBLE MASONRY using hard granite stones obtained from approved 250.000In cement mortar 1:6. Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) including raking out joints, 370.000a) Flush pointing. Providing and laying cement concrete using graded hard granite stone aggregate of 20mm nominal size 10.000P.C.C 1:3:6 Plastering 15mm thick with cement mortar specified below finished rough including scaffolding, 40.000a) With C.M. 1:6 Providing and constructing RANDOM RUBBLE MASONRY using hard granite stones obtained from approved 144.000In cement mortar 1:6.

130.00

CUM

6,760.00

82.50

CUM

20,625.00

1.53

SQM

566.10

220.00

CUM

2,200.00

4.30

SQM

172.00

82.50

CUM

11,880.00 42,203.10

Total of Part : B

Noticeno 98725

Page 48

04/25/12

CEMENT REQUIREMENT Item No SOR Code Quantity Control room Providing and laying cement concrete using 40mm nominal size graded hard granite stone aggregate 57.000In foundation and plinth/sub-base to floors with P.C.C 1:5:10 Providing & laying in position machine batched, machine mixed and machine vibrated design mix 80.000 Description Coefficient Unit Theoretical consumption

Part : C 0005 0005a 0007 0007a 0007b 0007c 0008 0008a 0009 0009a 0010 0010a 0012 0012a 0012b 0013 0013a 0014 0014a 0015a 0023 0023a 0024 0024a 0025 0025a 0025b 0026 0026a 0030 0030a 0031a 0032 0032a 0033 C010 C010A D033 D033C D033A D033B B050 B050F B060 B060F B090 B090D K005 K005B K005C K015 K015B K020 K020B J200A G050 G050A H060 H060C H175 H175A H175B H282 H282A H050 H050A L035A K305 K305A J220

130.00

CUM

7,410.00

380.00 10.000Walls ( any thickness) including attached pilasters, buttresses, 380.00


plinth and string courses, 71.000Beams, suspended floors, roofs having slope upto 15 degree, landings, balconies, shelves, chajja, Providing and constructing BRICK MASONRY in cement mortar as per mixes stipulated below using 5.000USING BRICKS OF CLASS DESIGNATION "4.5"(Minimum Average Compressive strength not less than 4.50 Providing and constructing BRICK MASONRY in cement mortar as per mixes stipulated below using 50.000USING BRICKS OF CLASS DESIGNATION "4.5"(Minimum Average Compressive strength not less than 4.5 Providing and constructing HALF BRICK MASONRY walls/partitions in the following mixes using 150.000USING BRICKS OF "CLASS DESIGNATION 4.5"(Minimum Average Compressive strength not less than 4.5 Plastering 12mm thick with cement mortar specified below, finished smooth with lime neeru, including 375.000b) With C.M 1:5. 425.000c) With C.M 1:4. Plastering 15mm thick with cement mortar specified below, finished smooth with lime neeru including 50.000b) With C.M. 1:5 Plastering 15mm thick with cement mortar specified below finished rough including scaffolding, 270.000b) With C.M. 1:5 280.000Providing and laying water proofing treatment over RCC roof in 3 courses, as specified below, after Providing and fixing pivoted steel windows/ ventilators side hung/ central hung/ top hung made 16.000Steel glazed fully openable windows/ventilators with shutters top hung/ central hung/ side hung Providing and laying Indian patent stone flooring with cement concrete 1:2:4 (1cement: 2 coarse 80.00040mm thick (Using 20mm nominal size stone aggregate) Providing and laying Ceramic tile flooring/dadoing of approved quality, size, colour and thickness 20.000In flooring with approved colour floor tiles ( Regular / plain or dark colour/ glossy or mat

CUM CUM CUM

30,400.00 3,800.00 26,980.00

380.00

62.50

CUM

312.50

62.50

CUM

3,125.00

12.60

SQM

1,890.00

4.46 5.47

SQM SQM

1,672.50 2,324.75

5.33

SQM

266.50

5.33 23.43

SQM SQM

1,439.10 6,560.40

1.30

SQM

20.80

15.00

SQM

1,200.00

10.14

SQM SQM

202.80 405.60

40.000In dado with approved colour wall tiles ( Regular / plain or dark 10.14 colour/ glossy or mat series) size Providing and laying vitrified ceramic tile flooring / skirting using approved quality 140.000Tile size of 600 x 600mm of marble series

14.72 320.00 0.90

SQM

2,060.80

11.000Using 20mm nominal size agreegate In CC 1:3:6. 165.000Providing and laying angular fillet 7.5x7.5cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 Providing plaster drip/ moulding of size as specified below in cement mortar 1:3 (1 cement :3 165.000a ) 45mmx15mm size Providing and fixing rigid PVC SWR (soil, waste and rain water) drainage / rain water pipe

CUM RMT

3,520.00 148.50

1.50

RMT

247.50

Noticeno 98725

Page 49

04/25/12

CEMENT REQUIREMENT Item No SOR Code Quantity Control room 25.000c) 160mm dia OD pipes with minimum wall thickness of 3.20 mm Providing and laying light duty Non-pressure NP-2 Class R.C.C Hume pipes with collars jointed with 24.000b) 150mm dia Providing and constructing RANDOM RUBBLE MASONRY using hard granite stones obtained from approved 15.000In cement mortar 1:6. Description Coefficient Unit Theoretical consumption

Part : C 0033a 0035 0035a 0036 0036a J220C O010 O010B B010 B010A

6.88

RMT

172.00

0.60

MTR

14.40

82.50

CUM

1,237.50 95,410.65

Total of Part : C Part : D 0002 0002a 0003 0003a 0004a 0005a 0013 0013a 0013b 0013c 0014a 0016 0016a 0016b 0018a 0019a 0020 0020a 0020b 0020c 0022a X020 X020A X050 X050A X065A X105A X175 X175N X175B X175C X185A X210 X210A X210B Y050B Z005A Z015 Z015A Z015B Z015C Z035A PH works ( Internal & external) X.04) Providing and Fixing Indian Style Water Closet Suite (Orissa pan) Comprising of : A) 2.000X.04.1) With 'S' trap X.10) Providing and Fixing Indian make wash hand basin (with CP bottle trap) Comprising of : A) 2.000X.10.1) Size 550 X 400 mm 2.000X.13) Providing and Fixing in position large urinal comprising of : A) White glazed vitreous 3.000X.21) Providing and Fixing in position best Indian make Marble partition slab for urinals, X.34) Providing, laying, jointing, fixing, testing,commissioning threaded PVC pipes schedule 150.000X.34.2.6) For External works - 50mm n.b. 10.000X.34.1.2) For Internal works - 20mm n.b. 85.000X.34.1.3) For Internal works - 25mm n.b. 7.000X.36) Providing and fixing UPVC floor trap with 75mm dia outlet "Supreme" or other equivalent X.41) Providing and Laying best quality salt glazed stoneware pipe of grade A and specials 15.000X.41.1) 100mm Dia 30.000X.41.2) 150mm Dia 2.000Y.11) Construction of valve chamber of size 600X600mm, 750mm deep comprising of 230mm thick 2.000Z.01) Providing and Fixing in position best quality salt glazed stoneware gully trap of size Z.03) Construction of Inspection chamber of internal clear dimensions as mentioned below in 2.000Z.03.1) 450X450X450mm with frame and cover of size 450X450mm weighing not less than 25Kg. 2.000Z.03.2) 600X600X600mm with frame and cover of size 610X450mm weighing not less than 38Kg. 1.000Z.03.3) 600X600X750mm with frame and cover of size 610X450mm weighing not less than 38Kg. 2.000Z.07) Construction of Manhole of internal clear dimensions 800X800mm in 230mm thick brick masonry

5.00

EACH

10.00

1.50 1.00 2.00

EACH EACH EACH

3.00 2.00 6.00

0.50 1.00 1.00 6.00

MTR MTR MTR EACH

75.00 10.00 85.00 42.00

1.67 2.50 166.00 57.00

MTR MTR EACH EACH

25.05 75.00 332.00 114.00

175.00 252.00 274.00 469.00

EACH EACH EACH EACH

350.00 504.00 274.00 938.00 2,845.05

Total of Part : D Part : E 0002 0002a 0004 0004a 0004b 0005 0005a C010 C010B D033 D033A D033B C022 C022D Septic Tank Providing and laying cement concrete using 40mm nominal size graded hard granite stone aggregate 2.000In foundation and plinth/sub-base to floors with P.C.C 1:4:8 Providing & laying in position machine batched, machine mixed and machine vibrated design mix 6.500Walls ( any thickness) including attached pilasters, buttresses, plinth and string courses, 6.500Beams, suspended floors, roofs having slope upto 15 degree, landings, balconies, shelves, chajja, Providing and laying cement concrete using 20mm nominal size graded hard granite stone aggregate 2.500P.C.C 1:3:6 Page 50

130.00

CUM

260.00

380.00 380.00

CUM CUM

2,470.00 2,470.00

220.00

CUM

550.00 04/25/12

Noticeno 98725

CEMENT REQUIREMENT Item No SOR Code Quantity Septic Tank Water proof cement plastering of thickness as specified below in cement mortar 1:3 (1 cement : 3 120.000C) 15mm thick Description Coefficient Unit Theoretical consumption

Part : E 0007 0007a K040 K040C

8.57
Total Requirement in Kgs :

SQM

1,028.40 6,778.40 5,92,445.85

Total of Part : E

Noticeno 98725

Page 51

04/25/12

Name of Work : Construction of 300 gallon Vertical Mixer Building no.4 at SPROB.

HYSD BARS REQUIREMENT Item No SOR Code Quantity Mixer building Steel reinforcement for all R.C.C items including decoiling, cutting, hooking, bending, cranking, 130.000With high yield strength deformed bars. Description Coefficient Unit Theoretical consumption

Part : A 0010 0010a F010 F010B

1.00

M.T

130.00 130.00

Total of Part : A Part : C 0016 0016a F010 F010B Control room Steel reinforcement for all R.C.C items including decoiling, cutting, hooking, bending, cranking, 30.000With high yield strength deformed bars.

1.00

M.T

30.00 30.00 160.00

Total of Part : C Total Requirement in Kgs :

Noticeno 98725

Page 52

04/25/12

Name of Work : Construction of 300 gallon Vertical Mixer Building no.4 at SPROB. Part : Part name

Amount

A B C D E

Mixer building Earthern Merlon Control room PH works ( Internal & external) Septic Tank Grand total : Rs.

1,46,15,292.78 15,12,442.12 35,28,126.05 1,43,023.87 1,03,060.49 1,99,01,945.31

Noticeno 98725

Page 1

04/25/12

Você também pode gostar