1 of 19 Rosenberger Asia Pacific Electronic Co., Ltd Tel: +86 10 80481995 Fax: +86 10 80482438
CATALOGUE
1 OVERVIEW............................................................................................................................... 3
2 of 19 Rosenberger Asia Pacific Electronic Co., Ltd Tel: +86 10 80481995 Fax: +86 10 80482438
1 Overview
Repeater operation & maintenance terminal (OMT) interact with the repeater to set and lookup its status and RF parameters. It can display alarms real-time. OMT can set local connection, wireless data connection or SMS connection with the device for operation and maintenance at any time, or at any location. OMT and repeater connection topology:
OMT
OMT
Computer
RS232
Computer
RS232
Local mode
Remote mode
2 User Guide
Start the application, The top menu are Configure, Visit, Advanced and Help.
Figure 2
3 of 19 Rosenberger Asia Pacific Electronic Co., Ltd Tel: +86 10 80481995 Fax: +86 10 80482438
2.1 Configure
Click Configure menu. Configuration items pop up as Figure 3:
Figure 3
Figure 4 b) Select the serial port for communications, for example, COM1. Then click the next button Port . As
Figure 5:
Figure 5 c) d) The default setting is usually used. Click OK to return.. On Remote Connection dialog box, modem initiate string can be specified in Modem Init text box. The
default modem initiate string is ATE1V1S0=2, which set the modem to echo mode, answer the incoming call on the second ring and auto-answer mode. Click Default button can set the default value, As Figure 6. e) When the SMS center number is not specified in the SIM card in the wireless modem, user shall specify
4 of 19 Rosenberger Asia Pacific Electronic Co., Ltd Tel: +86 10 80481995 Fax: +86 10 80482438
OMT Software User Manual the SMS center number in the SMS center number text box:
Figure 6
Figure 7 b) Local connection only needs setting on the serial ports. Other operations are same as remote connection.
Notice: all settings are saved in the configuration file. As far as the serial port or the device doesnt change, user neednt to do the setting again for the next time.
Figure 8
2.2.2 Connect
a) Click Connect menu item or the button on the toolbar. As the Figure 9:
5 of 19 Rosenberger Asia Pacific Electronic Co., Ltd Tel: +86 10 80481995 Fax: +86 10 80482438
Figure 9 b) Choose a connection mode, which can be Local, SMS or Data. Then user shall select the repeater to
connect. If the repeater is listed on the dialog box, user can highlight the item then click Connect. Otherwise, user shall add the repeater in the list. The button Set is used to modify repeater information. Click the button Add. The following dialog box pops up:
Figure 10 Repeater Name is to identify the repeater. If the OMT use Remote method to connect repeater, user must specify the Phone Number.
6 of 19 Rosenberger Asia Pacific Electronic Co., Ltd Tel: +86 10 80481995 Fax: +86 10 80482438
OMT Software User Manual Whatever the connection mode is used, Repeater ID and Device ID must be specified, which is a unique number to identify the repeater in the network. Repeater ID ranges between 1 and 4294967295, which Repeater Operation Management Center software (OMC) assign after the repeater is available for service. It shall be set to 0 in the stage of installation. Device ID is for component device in co-frequency repeater. It shall be set to the default value: 255 for other types of repeaters. User can specify the type of repeater on dropdown list box of Repeater Type. c) For example, user select Channel selective repeater as repeater type, as Figure 11.
Figure 12 Click OK button, an item is added into the list. As following figure:
7 of 19 Rosenberger Asia Pacific Electronic Co., Ltd Tel: +86 10 80481995 Fax: +86 10 80482438
Figure 13 Click Set button can modify the parameters for the selected repeater. The popup dialog box is as same as one in the Figure 6. Click Delete button to delete a profile of repeater connection. Click Connect button will connect to a selected repeater. Notice: These settings are saved in the configuration file. User neednt to do the setting again for the next time.
port, user can use a USB-to-Serial cable for this purpose. Main window is as the following:
8 of 19 Rosenberger Asia Pacific Electronic Co., Ltd Tel: +86 10 80481995 Fax: +86 10 80482438
Figure 14 b) There are two tabs in the main window: Basic INFO and Engineering parameter. User can click the
title to switch tab. Engineering parameter Tab: Only 2 types of actions can be performed: Get and Set. Get: Click Get button to query the value from the repeater. Set: Not all parameters for repeater can be modified. A Set checkbox follows a parameter which user can modify. Check the checkbox, and input value into the textbox, then click Set button to modify the parameter.
9 of 19 Rosenberger Asia Pacific Electronic Co., Ltd Tel: +86 10 80481995 Fax: +86 10 80482438
Figure 15 c) i. The Basic INFO tab is used as following: Click Get button to query the respective parameters. As figure 14. User can click Get All button on the
bottom of the window the get all parameters from the repeater while OMT send multiple query command to it. As Figure 16.
10 of 19 Rosenberger Asia Pacific Electronic Co., Ltd Tel: +86 10 80481995 Fax: +86 10 80482438
11 of 19 Rosenberger Asia Pacific Electronic Co., Ltd Tel: +86 10 80481995 Fax: +86 10 80482438
Figure 17 iii. Setting Parameters. For example, set the value for gain in uplink and downlink: As Figure 17, repeater maximum gain is 88dB. The gain is set to 70 dB (Deduct 18 dB attenuation from 88 dB). To set the gain to 80 dB, as following: Check Set checkbox next to Uplink/downlink attenuation value. Then input the value in the attenuation textbox, as the following figure:
12 of 19 Rosenberger Asia Pacific Electronic Co., Ltd Tel: +86 10 80481995 Fax: +86 10 80482438
Figure 19 After inputting the value, click Update button on the bottom of the window. As the following figure:
Figure 20 When the setting is applied successfully, OMT will popup an information window. As following:
13 of 19 Rosenberger Asia Pacific Electronic Co., Ltd Tel: +86 10 80481995 Fax: +86 10 80482438
Figure 21 It indicates setting ATTN value successfully. Otherwise, it will prompt the dialog box indicate the operation failed. Notice: when user input the wrong ID to connect repeater, all operation will be failed. System will prompt error message as following:
Figure 22 To work with the repeater, user can set the Repeater Id and Device Id same as the repeater connection setting (Figure 10). As Figure 23:
14 of 19 Rosenberger Asia Pacific Electronic Co., Ltd Tel: +86 10 80481995 Fax: +86 10 80482438
OMT Software User Manual ordinary circumstance, it takes between 30 and 60 seconds for the repeater to respond a command. So user shall commit Get and Set action one by one to improve response speed. The message window will indicate short message sent successfully when the command is executed successfully. As Figure 24:
Figure 24
Figure 25 After being connected successfully, the main window shows. a) Using dial up, connection is difficult to setup and data communication is slow and unreliable. User can
click the Dial up button in the toolbar to redial when the dialup connection is disconnected. As the following figure:
Figure 26 b) User can click Hang up button to hang up the connection. As the following figure:
15 of 19 Rosenberger Asia Pacific Electronic Co., Ltd Tel: +86 10 80481995 Fax: +86 10 80482438
Figure 27 c) User can click button to force disconnecting when the system has no response to hang up command. As
Figure 28
d) Disconnecting
User can click Disconnect menu or the button Disconnect in the toolbar to disconnect the dialup connection and close the repeater information window. As the following figure:
Figure 29
Figure 31 Select the file to download. Then click Download button to start software update. Click Cancel button to
16 of 19 Rosenberger Asia Pacific Electronic Co., Ltd Tel: +86 10 80481995 Fax: +86 10 80482438
OMT Software User Manual cancel download. Software downloading is as the following figure:
Figure 32 A message box will pop up after downloading successfully. Then repeater reboot. b) CPU reset
Click CPU Reset button to reboot repeater. The function is similar Reset button on PC. c) Repeater Clock
Figure 33 It is convenient for user to lookup and to update the repeater clock on the dialog box. d) History Alarm
User can view the history alarm kept on the repeater. As the following figure:
17 of 19 Rosenberger Asia Pacific Electronic Co., Ltd Tel: +86 10 80481995 Fax: +86 10 80482438
Figure 34 Click Delete button to delete the history alarms in the repeater.
2.4 Help
Click help to open user guide.
from one mode to another automatically. User can send command to switch the working mode. Working with local mode, user can switch arbitrarily. However, in remote mode, user shall know which mode he/she working with. Then he/she use command to switch the system from one to another. For example, user works in SMS mode. He/she shall use OMT to send a SMS command to switch the working mode to data mode. Repeater receives the SMS. If repeater accept the command, it reply a successful setting SMS. After the message is sent successfully, repeater is switched to data mode. Then, user shall use data mode to query and set parameters in the repeater. b) To remotely control, the specified phone number shall be same as MOC Query/Control phone NO.
Otherwise, user cant set parameter but query parameter in the repeater. As the following figure:
18 of 19 Rosenberger Asia Pacific Electronic Co., Ltd Tel: +86 10 80481995 Fax: +86 10 80482438
OMT Software User Manual Figure 35 c) In SMS mode, SMSC phone No. in Engineering Parameter tab must be specified correctly. Otherwise
Figure 36 d) In data mode, OMT software has 1 minute timing protection on the packages sent out. When data
connection is established, we suggest user wait about 20 seconds to execute commands against repeater. If the system has no response, user shall wait more than 1 minute for OMT. e) For closed repeater, user shall reset cut the power supply of the repeater after inserting SIM card.
19 of 19 Rosenberger Asia Pacific Electronic Co., Ltd Tel: +86 10 80481995 Fax: +86 10 80482438