Bock CO2 Compressors

Semi-hermetic Compressors for the Refrigerant R744

engineering for a better world

GEA Refrigeration Technologies

In touch with our customers

GEA Refrigeration Technologies:


Your partner for low temperatures
GEA Refrigeration Technologies, part of the internationally active GEA Group, is a synonym
for industrial refrigeration technology. Since the end of the 19th century, it has been our business to cool processes and products, and to control the temperature of goods in transport.
You will find our solutions in the food and beverage sector; in the petrochemical, chemical,
and pharmaceutical industries; on fishing ships; in natural gas liquefaction; in infrastructure
facilities; and in ice factories. We are also at the top with know-how when it comes to refrigeration at leisure facilities. After all, we have been excited about refrigeration for decades now.
As a result, our staff enthusiastically goes about its development and production projects to
include preventive and remedial maintenance of your refrigeration systems.
This enthusiasm is highly apparent in the daily work of all companies in our Segment.
Whether its complete systems or individual valves: we have the experience in every section
of our company to optimally design, manufacture, and install refrigeration systems. And to
take full advantage of this experience, we not only carry out development in our own company: we also manufacture, assemble, and test the core components. A chain is, after all, only
as strong as its weakest link: and this also applies equally well to refrigeration technology,
cooling processes, and cooling chains.
This makes it all the more important that you have a partner in GEA Refrigeration Technologies that has learned to master refrigeration from A to Z. And all of this since 1896, when
Willem Grasso founded his refrigeration division. From this history of GEA Refrigeration
Technologies, you will profit in the form of technical expertise and top sector know-how.
But we all live in the present and think about the future. We ponder a future in which more
and more processes need energy around the world, and fewer natural resources are available. As a result, we have taken it as our goal to create solutions that are not only long-life
and cost-effective, but also energy-saving and environment-protecting. We feel obligated to
sustainability in many respects. Our objective is to produce longlife and material-saving products over the long run as well as products that use environmentally benign refrigerants.
And we aim to produce efficiently. But our responsibility does not end at the factory gate.
As a result, we take great pains to ensure that our systems are energy-efficient and that they
protect the climate. With GEA Refrigeration Technologies, you can also count on optimal
economy: saving energy indeed means reducing money spent for energy. At the same time,
you protect the environment. Thanks to our refrigeration technology, your processes will run
more economically and more ecologically. To maintain our standard of living and to assure
quality of life for future generations as well.
Our claim of combining economy with saving natural resources is reflected in all components of our company, such as the following: compressors, chillers, heat pumps, ice machines,
fittings and valves, control systems, and many, many more. You can find proof of the above
throughout the world. Our international corporate network and above all our reference
projects are spread all over the globe.

2 | www.bock.de

96219-02.2012-Gb Subject to change without notice

Bock Compressors

CO2 compressors subcritical I

CO2 compressors transcritical I

CO2 radial piston compressors transcritical I

Service - Made by GEA Bock I

Disclaimer
This brochure has been produced for you with the greatest of care. Nevertheless it
is not possible to rule out mistakes completely. In such cases we cannot assume any
liability. The contents correspond to the status on going to print. Deviations cannot
be ruled out because of the ongoing developement process for our products.

96219-02.2012-Gb Subject to change without notice

The details are provided as unbinding general information and cannot substitute
detailed, individual consultation. Reprints even only of excerpts only allowed with
the explicit approval of GEA Bock GmbH. GEA Bock GmbH 2012

www.bock.de | 3

GEA Bock - More than a compressor


Over 75 years ago, when the refrigeration and air-conditioning
industry was still in its infancy, our company's founder, Wilhelm
Bock, had a vision: he wanted to build first-class and reliable refrigeration machines. In the following decades Bock developed into
one of the world's leading manufacturers of refrigeration and airconditioning compressors.
Today, GEA Bock offers as part of GEA Refrigeration Technologies
the right compressor for all fields of commercial-, industrial-, rail-,
bus- and transport refrigeration.
Sustainable refrigeration technology is in the focus of product
development at GEA Bock for many years. Already in the mid-90s
Bock compressors were the heart of the first transcritical CO2 refrigeration systems in mobile and stationary applications.
Today GEA Bock offers a wide range of CO2 compressors for
subcritical and transcritical application areas.
Be inspired. By our new products, our established product series
and the entire passion that goes into each of our products.

4 | www.bock.de

96219-02.2012-Gb Subject to change without notice

Bock Compressors

Production Program

Semi-hermetic compressors HG (HA)


The Bock HG (Hermetic Gas-cooled) range of semi-hermetic compressors offers traditional
suction gas-cooled compressor state of the art technology. These compressors of the highest
quality standard excel in their running comfort, easy maintenance, efficiency and reliability. Suitable as standard for conventional or chlorine-free HFC refrigerants.
The HA (Hermetic Air-cooled) range, specially engineered by GEA Bock, is available for
deep-freezing applications, in particular for use with the refrigerants R22 and R404A.
Single-stage

R410A compressors

Two-stage compressors

CO2 compressors subcritical

ATEX compressors

Duplex compressors

CO2 compressors transcritical HC compressors

Compressor units with receiver

R134a compressors

Aluminium compressors Condenser units air-cooled

R407C compressors

2-pole compressors

Vehicle compressors FK
Bock vehicle compressors of the FK range are the result of many years of experience in the
domain of mobile cooling systems.
The unsurpassed light, compact, robust design and wide r.p.m. range are only some of the
outstanding features of this unique product range of two, four and six cylinder compressors.
A wide variety of designs can be tailored to suit individual requirements.
The so-called K version is a special innovation with a unique valve plate system for
maximum requirements in bus and coach air-conditioning systems.
Compressors for bus and train air-conditioning
Compressors for transport refrigeration and other applications

Open type compressors F


The F model series provides modern open type compressors for separate drive systems
(using V belts or direct couplings). Load transfer through a V pair.
Virtually all drive capacity requirements can be met.
Very compact compressor design, robust and easy to handle. Oil pump lubrication as
standard.
Single-stage compressors
NH3 compressors
Compressor units for direct drive
NH3 Compressor units for direct drive

96219-02.2012-Gb Subject to change without notice

www.bock.de | 5

6 | www.bock.de

96219-02.2012-Gb Subject to change without notice

Bock CO2 compressors


subcritical
At a glance
Operating limits
Performance data
Technical data
Dimensions and connections
Scope of supply and accessories

96219-02.2012-Gb Subject to change without notice

8
13
14
17
18
23

www.bock.de | 7

CO2 Compressors (subcritical)

At a glance

CO2 Compressors (subcritical)

The refrigerant R744


Based on our current semi-hermetic product range, with its outstanding advantages and
Our solutions are customeroriented

and

user-friendly,

because they are low-priced,


energy-efficient, long-lasting
and tailored to your individual needs.

features, as well as our longstanding activities, we are now expanding the bottom end of
our CO2 compressor series for subcritical cascade systems.
Especially suited to supermarket refrigeration applications and industrial refrigeration.
Max. permissible operating pressure up to 55 bar at the high pressure side and 40 bar at
the low pressure side.
Special features
As Bock compressors are of extremely high quality and robust, the coordination with
CO2 is limited primarily to the motor design together with the individual mechanism
adjustments as well as small modifications in the valve and seal areas.
This permits the greatest possible level of operational safety through the extensive use
of tried-and-trusted standard parts. In addition, there are the best possible conditions for
economic spare part storage.
The refrigerant CO2
Within refrigeration technology, carbon dioxide (CO2) is known by the name R744 and
has a long history.
It is a colourless gas which liquefies under pressure and has a slightly acidic smell and
taste. Carbon dioxide has no ozone depletion potential (ODP = 0) and a negligible direct
effect on global warming (GWP = 1) when used as a refrigerant in closed systems.
It is not combustible, is chemically inactive and heavier than air. Carbon dioxide has a
narcotic and asphyxiating effect on humans only at higher concentrations.
Carbon dioxide is available naturally in large quantities.

8 | www.bock.de

96219-02.2012-Gb Subject to change without notice

CO2 Compressors (subcritical)

At a glance

The current program


...4 model sizes with 15 capacity stages from 2,8 to 48,2 m/h (50 Hz)
50

Displacement
m3/h
/h
Hubvolumen m

25

HGX34P CO2

HGX22P CO2

HGX12P CO2

HGX4 CO2

1
2

Type key

HGX34P / 215 - 4 CO2

4
CO2 Version 4)
Number of poles
Swept volume
Pluscom 3)
Number of cylinders 3)
Size
Ester oil filling
Series 1)

96219-02.2012-Gb Subject to change without notice

2)

1)

HG = Compressor Hermetic Gas-cooled (suction gas-cooled)

2)

= Special Ester oil for CO2

3)

= Additional declaration for Pluscom compressors

4)

CO2 design for subcritical applications

www.bock.de | 9

CO2 Compressors (subcritical)

At a glance

Wear-resistant durable driving gear


-- Solid construction and design
-- Low friction sleeve bearings
-- Aluminium piston with two ring assembly

Valve plate construction for safe operation


-- Valve design, tried and trusted all over the world, with onesided
fixed finger reed valves, suction and pressure side

-- Valve made out of high quality, impact resistant spring steel

Quiet with low vibrations


-- Large dimensioned crankshaft area

-- High volume pressure area to dampen pulsations

-- Dynamic mass balance

-- 4 cylinder construction from 19 m/h

Co2 Refrigeration oil C85E

Oil

40

The compressors are equipped with Bock C85E, a special oil filling,
phase separation

which is available directly from GEA Bock. This is a synthetic ester


oil with high thermal load resistance, allowing good mixing solubility

20

with CO2. It possesses a special additive, which protects the compres-

complete
miscibility

sors against wear, even when subjected to extreme loads, such as those which exist in CO2 systems. This oil can be used both in transcritical
and subcritical systems.

t emperature [C]

-20

-40

20

40

60

concentration [M-%oil in CO2]

10 | www.bock.de

96219-02.2012-Gb Subject to change without notice

CO2 Compressors (subcritical)

At a glance

Reliable and safe oil supply


-- Classic lubricant circuit with an oil pump independent of the
rotating direction

-- High volume oil sump


-- Special oil charge for CO2: Bock C85E,
directly available from GEA Bock

Oil sump heater

1
2
3
4

-- Standard in HGX12P, HGX22P and HGX34P

-- Standard in HGX4

-- PTC heater, self-regulating version, installation in housing bore

-- Design with immersion sleeve

-- Replacement possible without opening the refrigerating circuit

-- Replacement possible without opening the refrigerating circuit

Thermal protection thermostat


Pressure gas temperature monitoring, PTC sensor direct connection
to the Bock MP10 motor protection

96219-02.2012-Gb Subject to change without notice

www.bock.de | 11

CO2 Compressors (subcritical)

At a glance

Economic capacity control


Continuously variable speed control using Bock EFC
(Electronic Frequency Control)
optional for HGX12P, HGX22P, HGX34P

-- compact installation on compressor and connected ready for use


-- up to 25% lower energy consumption
-- for HGX4 infinite speed control through external frequency
converter (Bock EFCe)

-- Further information see separate brochure "Bock semi-hermetic


compressors - Electronic Controls".

Bock MP10 electronic motor protection (standard)


-- Temperature monitoring with PTC sensors and optical status
indication

-- Discharge gas temperature sensor (option)


-- Further information see separate brochure "Bock semi-hermetic
compressors - Electronic Controls".

Start unloader using Bock ESS (option)


Electronic Soft Start
-- Optional for HGX22P and HGX34P
-- Soft compressor start from zero to nominal speed, time controlled
and monitored
-- No standard unloaded start required
-- IP20 unit for control cabinet installation (included loose)

-- Further information see separate brochure "Bock semi-hermetic


compressors - Electronic Controls".

12 | www.bock.de

96219-02.2012-Gb Subject to change without notice

CO2 Compressors (subcritical)

CO2 Operating limits

Operating limits

HGX12P CO2 1 , HGX22P CO2


HGX34P CO2 1 2, HGX4 CO2 1

Unlimited application range

tO

Evaporating temperature (C)

tC

Condensing temperature (C)

tOh Suction gas superheat (K)

1 HGX12P/75-4 CO2 , HGX34P/215-4 CO2


HGX4/385-4 CO2 , HGX4/465-4 CO2
Max. condensing temperature
tC = 0 C

Max. permissible operating pressure (LP/HP)1)

2 HGX34P/255-4 CO2
Max. condensing temperature
tC = -5 C

Max. permissible operating pressure (LP/HP)1)

for HGX4: 27/55 bar


1)

3 HGX4/555-4 CO2
Max. condensing temperature
tC = -7,5 C

for HGX12, HGX22 and HGX34: 40/55 bar

LP = low pressure HP = high pressure

CO2 Notes
Operating limits

Performance data

Compressor operation is possible within the limits shown on the

The performance data for CO2 are based on 20 K suction gas super-

application diagrams. Please note the coloured areas. Compressor

heat without liquid subcooling, at 50 Hz power supply frequency.

application limits should not be chosen for design purposes or con-

These are preliminary values as no uniform reference data are avai-

tinuous operation.

lable. Besides which the influence of the oil part on refrigeration performance is largely unknown. Variations cannot be excluded.

Restrictions to the operating limits may occur when using the Bock

Conversion factor for 60 Hz = 1,2

EFC (Electronic Frequency Control). Further information see separate


brochure "Bock semi-hermetic compressors - Electronic Controls".

Performance data for other operating points, see GEA Bock


software

96219-02.2012-Gb Subject to change without notice

www.bock.de | 13

CO2 Compressors (subcritical)

CO2
Type

Performance data

Performance data
Cond.

Cooling capacity QO [W]

temp.
-25

-15

HGX12P/30-4 CO2

-10
-5
0
-20
-15

HGX12P/40-4 CO2

-10
-5
0
-20
-15

HGX12P/50-4 CO2

-10
-5
0
-20
-15

HGX12P/60-4 CO2

-10
-5
0
-20
-15

HGX12P/75-4 CO2

-10
-5
0

Power consumption Pe [kW]


Evaporating temperature C

-20

50 Hz

Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P

7497
1,00
6970
1,25
6419
1,50

9601
1,26
8982
1,59
8295
1,95

12019
1,60
11227
1,99
10358
2,41

14493
1,89
13478
2,38
12435
2,90

18009
2,28
16703
2,92
15354
3,56

-30

6591
0,90
6150
1,12
5688
1,33
5210
1,55

8384
1,14
7859
1,41
7286
1,71
6664
2,01

10481
1,44
9813
1,76
9090
2,11
8308
2,49

12631
1,71
11774
2,12
10893
2,54
9995
2,98

15704
2,06
14617
2,61
13489
3,14
12335
3,68

-35

-40

-45

-50

5674
0,80
5306
1,00
4921
1,18
4523
1,36
4115
1,55
7236
1,06
6779
1,25
6295
1,49
5781
1,75
5235
2,01
9040
1,30
8463
1,56
7856
1,85
7213
2,16
6530
2,49
10855
1,56
10136
1,90
9394
2,23
8637
2,58
7877
2,97
13484
1,87
12587
2,33
11650
2,77
10690
3,21
9720
3,66

4482
0,89
4161
1,05
3830
1,20
3493
1,35
3153
1,51
5763
1,13
5342
1,31
4912
1,51
4470
1,73
4012
1,93
7195
1,40
6671
1,64
6137
1,89
5587
2,14
5015
2,41
8589
1,71
7965
1,97
7329
2,25
6690
2,54
6058
2,89
10652
2,08
9877
2,44
9081
2,79
8278
3,16
7482
3,55

3451
0,92
3174
1,04
2895
1,16
2618
1,29
2344
1,44
4451
1,16
4079
1,31
3716
1,49
3357
1,66
3000
1,81
5554
1,45
5096
1,65
4647
1,85
4200
2,06
3750
2,25
6634
1,76
6096
1,96
5557
2,18
5027
2,44
4515
2,75
8211
2,15
7549
2,43
6883
2,71
6227
3,01
5596
3,36

2599
0,90
2366
1,00
2137
1,10
1916
1,21

3303
1,15
2993
1,28
2708
1,42
2445
1,54

4107
1,45
3727
1,61
3374
1,75
3042
1,89

4966
1,72
4506
1,88
4057
2,06
3627
2,28

6134
2,10
5576
2,31
5030
2,54
4511
2,80

Relating to 20 K suction gas superheat


without liquid subcooling

14 | www.bock.de

96219-02.2012-Gb Subject to change without notice

CO2 Compressors (subcritical)

CO2
Type

Performance data

Performance data

Cond.

Cooling capacity QO [W]

temp.
-25

-15

HGX22P/110-4 CO2

-10
-5
0
-20
-15

HGX22P/125-4 CO2

-10
-5
0
-20
-15

HGX22P/160-4 CO2

-10
-5
0
-20
-15

HGX22P/190-4 CO2

-10
-5
0
-20
-15

HGX34P/215-4 CO2

-10
-5
0
-20
-15

HGX34P/255-4 CO2

-10
-5
0

Power consumption Pe [kW]


Evaporating temperature C

-20

50 Hz

Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P

25076
3,25
23420
4,11
21608
5,04

29581
3,85
27641
4,85
25513
5,94

36527
4,75
34112
6,00
31465
7,34

43940
5,73
41076
7,22
37909
8,80

50516
6,52
46888
8,32
43122
10,11

58817
7,62
54985
9,61

-30

21879
2,95
20483
3,64
18963
4,40
17329
5,20

25813
3,49
24183
4,29
22386
5,19
20465
6,14

31876
4,29
29843
5,30
27634
6,41
25259
7,57

38332
5,17
35915
6,39
33275
7,70
30415
9,09

43976
5,85
40964
7,36
37822
8,83
34592
10,35

51421
6,92
48070
8,58
44587
10,34

-35
18847
2,71
17661
3,25
16386
3,86
15031
4,51
13604
5,18
22221
3,21
20860
3,84
19352
4,56
17741
5,33
16068
6,13
27458
3,92
25727
4,72
23873
5,62
21907
6,57
19842
7,550
33044
4,70
30961
5,69
28740
6,76
26379
7,90
23880
9,08
37695
5,27
35215
6,54
32614
7,75
29933
8,97
27215
10,26
44289
6,31
41502
7,63
38461
9,08
35377
10,61

-40
14985
2,93
13906
3,39
12782
3,92
11619
4,46
10426
5,00
17693
3,45
16434
4,02
15091
4,64
13708
5,29
12325
5,92
21833
4,25
20253
4,95
18615
5,71
16931
6,50
15215
7,30
26301
5,09
24386
5,95
22415
6,87
20388
7,82
18306
8,78
29752
5,83
27608
6,83
25393
7,80
23149
8,81
20918
9,92
35187
6,83
32671
7,97
29990
9,20
27354
10,49

-45
11554
3,01
10612
3,41
9665
3,84
8723
4,27
7792
4,67
13654
3,54
12538
4,04
11402
4,56
10289
5,05
9239
5,51
16844
4,39
15452
4,97
14069
5,59
12707
6,22
11377
6,83
20299
5,26
18607
5,98
16941
6,73
15301
7,48
13690
8,21
22915
6,03
21082
6,80
19228
7,58
17395
8,44
15627
9,44
27123
7,05
24928
7,98
22656
8,99
20520
10,02

-50
8553
2,99
7774
3,31
7033
3,64
6339
3,95

10104
3,50
9175
3,91
8288
4,30
7486
4,64

12490
4,35
11326
4,82
10236
5,29
9233
5,74

15039
5,21
13623
5,79
12316
6,36
11120
6,90

17110
5,95
15562
6,55
14045
7,20
12600
7,96

20098
7,02
18273
7,74
16461
8,51
14872
9,27

Relating to 20 K suction gas superheat


without liquid subcooling

96219-02.2012-Gb Subject to change without notice

www.bock.de | 15

1
2
3
4

CO2 Compressors (subcritical)

CO2
Type

Performance data

Performance data
Cond.

Cooling capacity QO [W]

temp.
-25

-15

HGX4/310-4 CO2

-10
-5
0
-20
-15

HGX4/385-4 CO2

-10
-5
0
-20
-15

HGX4/465-4 CO2

-10
-5
0
-20
-15

HGX4/555-4 CO2

-10
-5
0

Power consumption Pe [kW]


Evaporating temperature C

-20

50 Hz

Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P

72216
9,39
67452
11,82
62223
14,44

89253
11,58
83376
14,62
76917
17,88

108690
13,99
101255
17,66
93763
21,59

128397
16,46
124273
18,70

-30

63011
8,49
58989
10,47
54627
12,63
49926
14,93

77885
10,46
72929
12,93
67534
15,62
61719
18,47

94098
12,64
87548
15,63
80934
18,88
74250
22,30

112043
15,07
104916
18,78
101110
20,70

-35

-40

-45

-50

54304
7,77
50853
9,33
47186
11,08
43304
12,96
39207
14,91
67112
9,56
62874
11,52
58340
13,70
53529
16,02
48458
18,43
81242
11,58
75597
13,93
69880
16,56
64088
19,36
58213
22,26
96522
13,72
90446
16,70
83925
19,84
80510
21,46

43175
8,39
40031
9,76
36797
11,26
33471
12,83
30055
14,42
53374
10,35
49498
12,06
45487
13,92
41360
15,86
37135
17,81
64619
12,52
59820
14,58
54938
16,83
49967
19,17
44900
21,52
76757
14,86
71198
17,34
65428
19,95
62478
21,30

33295
8,64
30535
9,80
27810
11,03
25117
12,28
22459
13,49
41168
10,67
37755
12,11
34368
13,63
31026
15,16
27749
16,65
49971
12,91
46019
14,65
41971
16,49
37821
18,34
33563
20,12
59196
15,27
54300
17,29
49429
19,42
47017
20,52

24652
8,55
22354
9,48
20214
10,43
18232
11,33

30494
10,56
27644
11,71
24983
12,88
22529
13,99

36548
12,79
33443
14,18
30228
15,59
26900
16,93

43843
15,27
39757
16,89
35932
18,58
34131
19,45

Relating to 20 K suction gas superheat


without liquid subcooling

16 | www.bock.de

96219-02.2012-Gb Subject to change without notice

CO2 Compressors (subcritical)

Number Displacement
of
50 / 60 Hz
Volcylinders (1450 / 1740 rpm) tage

CO2

Type

m/h

Technical data

Electrical data
Max.
working
current
2

Max.
power
consumption
2

kW

Connections

Weight

Oil
charge

Discharge
line
DV

Suction
line
SV

kg

mm I inch

mm I inch

Ltr.

Starting
current
(rotor locked)

2
A

/ Y

/ Y

HGX12P/30-4 CO2

2,80 / 3,40

5,9 / 3,4

1,8

40 / 23

49

12 I 1/2

16 I 5/8

0,9

HGX12P/40-4 CO2

3,60 / 4,40

7,3 / 4,2

2,3

43 / 25

53

12 I 1/2

16 I 5/8

0,9

HGX12P/50-4 CO2

4,50 / 5,40

8,7 / 5,0

2,9

43 / 25

53

12 I 1/2

16 I 5/8

0,9

HGX12P/60-4 CO2

5,40 / 6,40

9,5 / 5,5

3,2

45 / 26

49

12 I 1/2

16 I 5/8

0,9

HGX12P/75-4 CO2

6,70 / 8,10

10,6 / 6,1

3,6

45 / 26

49

12 I 1/2

16 I 5/8

0,9

HGX22P/110-4 CO2

9,40 / 11,30

18,9 / 10,9

6,0

121 / 70

83

16 I 5/8

22 I 7/8

1,1

HGX22P/125-4 CO2

11,10 / 13,30

20,9 / 12,1

7,2

121 / 70

78

16 I 5/8

22 I 7/8

1,1

HGX22P/160-4 CO2

13,70 / 16,40

25,6 / 14,8

8,8

121 / 70

82

16 I 5/8

22 I 7/8

1,1

HGX22P/190-4 CO2

16,50 / 19,80

29,9 / 17,3

9,9

134 / 77

84

16 I /8

22 I /8

1,1

HGX34P/215-4 CO2

18,80 / 22,60

32,4 / 18,7

11,1

134 / 77

98

16 I /8

22 I /8

1,4

HGX34P/255-4 CO2

22,10 / 26,60

32,4 / 18,7

11,1

134 / 77

98

16 I /8

28 I 1 /8

1,4

* PW 1+2

5
5
5

HGX4/310-4 CO2

27,10 / 32,50

28,2

16,5

82 / 107

152

22 I 7/8

28 I 11/8

3,4

HGX4/385-4 CO2

33,50 / 40,20

31,6

18,5

82 / 107

151

22 I 7/8

28 I 11/8

3,4

HGX4/465-4 CO2

40,50 / 48,60

38,3

22,3

107 / 140

154

28 I 11/8

35 I 13/8

3,4

HGX4/555-4 CO2

48,20 / 57,80

38,3

22,3

107 / 140

157

28 I 1 /8

35 I 1 /8

3,4

* PW = Part Winding, motors for part winding start

1 = 1. part winding

2 = 2. part winding

Explanations:
1

Tolerance ( 10%) relates to the mean value of the voltage


range. Other voltages and current types on request.

4 380-420 V Y/YY - 3 - 50 Hz PW
440-480 V Y/YY - 3 - 60 Hz PW
PW = Part Winding, motors for part winding start

- The specifications for max. power consumption apply for

(no start unloaders required)

50 Hz operation. For 60 Hz operation, the specifications

- Winding ratio: 66% / 33%

have to be multiplied by the factor 1.2.

- Designs for Y/ on request

The max. working current remains unchanged.


- T ake account of the max. operating current / max. power

5 For soldering connections

consumption when designing contactors, leads and fuses.


Switches: service category AC3
3

220-240 V / 380-420 V Y - 3 - 50 Hz

Oil sump heater 110-240 V - 1 - 50/60 Hz

265-290 V / 440-480 V Y - 3 - 60 Hz

HGX12P, HGX22P, HGX34P: 50-120 W


PTC heater, self-regulating, installation in housing bore
Oil sump heater 230 V - 1 - 50/60 Hz
HGX4: 80 W
Permanently set version, installation in immersion sleeve

96219-02.2012-Gb Subject to change without notice

2
3

*PW1 / PW 1+2

www.bock.de | 17

CO2 Compressors (subcritical)

Dimensions and connections

HGX12P/30-4 CO2

HGX12P CO2

66

ca.30

L1

ca.280
244

ca.115

A1
J1

DV B

B1

SV 1)

HGX12P/60-4 CO2
HGX12P/75-4 CO2

ca.240
100

SI1

SI2

HGX12P/40-4 CO2
HGX12P/50-4 CO2

H,D1

K,O

98F

ca.135
208

4x

318
ca.415

10
162
192

HGX22P/110-4 CO2
HGX22P/125-4 CO2

HGX22P CO2

HGX22P/160-4 CO2
HGX22P/190-4 CO2

88

DV B1

H,D1

ca.135

A1

109

Dimensions in mm
1)
SV 90 rotatable
Centre of gravity

18 | www.bock.de

ca.135
223

361
ca.505

115

SV 1)

ca.310
264

SI2

L1
A

B
SI1
E
F

K,O
J1
4x

12
198
ca.240

-- Connections see page 22


-- Dimensions for anti-vibration pad see page 20
96219-02.2012-Gb Subject to change without notice

CO2 Compressors (subcritical)

Dimensions and connections

HGX34P CO2

HGX34P/215-4 CO2

ca.285

B SI2 SI1

HGX34P/255-4 CO2

DV B1

L1

H,D1
K,O

E
F

J1

ca.165
310

4x

420
ca.510

HGX4/310-4 CO2
HGX4/385-4 CO2

2
3

HGX4/465-4 CO2
HGX4/555-4 CO2

ca.360
306

DV SI1 L1 A

A1
Q

436
535
ca.690

Dimensions in mm
1)
SV 90 rotatable
Centre of gravity
96219-02.2012-Gb Subject to change without notice

ca.180

SV 1)
A2

ca.405
278
170

ca.235

HGX4 CO2

73
112

12
230
272

B1

C
E
SI2
H
D1
O X
K

D
P
F
J1
4x

11
280
330

25

43
72

115

ca.135

A1
SV 1)
A1

ca.315
271

A2

-- Connections see page 22


-- Dimensions for anti-vibration pad see page 20
-- Dimensions for view X see page 21

www.bock.de | 19

CO2 Compressors (subcritical)

Dimensions and connections

Dimensions with accessories

HGX12P CO2

HGX22P CO2

HGX34P CO2

1 Additional fan

2 EFC Electronic Frequency Control

Type

mm

mm

mm

HGX12P CO2

ca. 460

ca. 500

ca. 315

HGX22P CO2

ca. 550

ca. 595

ca. 350

HGX34P CO2

ca. 550

ca. 620

ca. 350

Dimensions for anti-vibration pad


b
mm

c
mm

d
mm

HGX12P CO2

30

30

M8

20

HGX22P CO2

40

30

M10

20

HGX34P CO2

40

30

M10

20

HGX4 CO2

40

30

M10

20

20 | www.bock.de

a
mm

Type

c
a

96219-02.2012-Gb Subject to change without notice

CO2 Compressors (subcritical)

Dimensions and connections

Dimensions with accessories

HGX4 CO2

1
2
3
1 Additional fan

2 Intermediate adapter for discharge line valve

Type
HGX4 CO2

mm

mm

mm

mm

mm

mm

ca. 705

ca. 680

ca. 455

416

91

131

View X
Possibility to connect to oil level regulator

12

12
4

4
12

HGX4... CO2

Three-hole connection for oil level regulator


make ESK, AC+R, CARLY (3x M6, 10 deep)

Three-hole connection for oil level regulator


make TRAXOIL (3 x M6 x 10 deep)

4
12

47,6

Dimensions in mm

96219-02.2012-Gb Subject to change without notice

www.bock.de | 21

CO2 Compressors (subcritical)

Connections

Dimensions and connections

HGX12P CO2

SV
DV

Suction line
Discharge line

Connection suction side, not lockable

A1

Connection suction side, lockable

A2

Connection suction side, not lockable

Connection discharge side, not lockable

B1

Connection discharge side, lockable

Connection oil pressure safety switch OIL

Connection oil pressure safety switch LP

D1

Connection oil return from oil separator

Connection oil pressure gauge

Oil drain

HGX22P CO2

HGX34P CO2

HGX4 CO2

please refer to Technical data page 13


/8 " NPTF

/8 " NPTF

/16 " UNF

/16 " UNF

/8 " NPTF

/16 " UNF

/8 " NPTF

/16 " UNF

/4 " NPTF

/8 " NPTF

/8 " NPTF

/16 " UNF

/8 " NPTF

/8 " NPTF

/8 " NPTF

/8 " NPTF

/16 " UNF

/16 " UNF

/16 " UNF

/16 " UNF

/4 " NPTF

/4 " NPTF

/8 " NPTF

/8 " NPTF

/4 " NPTF

/8 " NPTF

M8

M 10

/8 " NPTF
/16 " UNF

M 10

M 22 x 1,5

Oil charge plug

/4 " NPTF

M 22 x 1,5

J1

Oil sump heater

15 mm

15 mm

15 mm

M 22 x 1,5

Sight glass

11/8" - 18 UNEF

11/8" - 18 UNEF

11/8" - 18 UNEF

4 hole M 6

L1

Thermal protection thermostat

Connection oil level regulator

SI1

Decompression valve HP

SI2

Decompression valve LP

Connection oil service valve

Connection oil differential pressure sensor

Connection oil temperature sensor

/4 " NPTF

/4 " NPTF

/8 " NPTF

/8 " NPTF

1 /8" - 18 UNEF
1

/8 " NPTF

1 /8" - 18 UNEF
1

/8 " NPTF

/8 " NPTF

1 /8" - 18 UNEF

/8 " NPTF

/8 " NPTF

/8 " NPTF
1

/8 " NPTF

/8 " NPTF

/8 " NPTF

/8 " NPTF

/4 " NPTF

M 20 x 1,5
1

/8 " NPTF

1 Dimensions see view X


1)

Only possible with additional adapter

22 | www.bock.de

96219-02.2012-Gb Subject to change without notice

CO2 Compressors (subcritical)

Scope of supply

Scope of supply

HGX12P CO2

HGX22P CO2

HGX34P CO2

HGX4P CO2

Semi-hermetic two cylinder reciprocating compressor


with drive motor for direct start
220-240 V / 380-420 V Y - 3 - 50 Hz
265-290 V / 440-480 V Y - 3 - 60 Hz
Single-section compressor housing with hermetically integrated electric motor
Semi-hermetic four cylinder reciprocating compressor
with drive motor for direct start
220-240 V / 380-420 V Y - 3 - 50 Hz
265-290 V / 440-480 V Y - 3 - 60 Hz
Single-section compressor housing with hermetically integrated electric motor
Semi-hermetic four cylinder reciprocating compressor
with drive motor for part winding start
380-420 V Y/YY - 3 - 50 Hz
440-480 V Y/YY - 3 - 60 Hz
Motor unit flanged onto the compressor housing
Winding protection with PTC resistor sensors and electronic
motor protection unit Bock MP10

Thermal protection thermostat (PTC sensor)

Oil pump cover with screwed connection for differential oil pressure
sensor (p-switch Kriwan make)
Connection possibility of oil level controllers
makes ESK, AC+R or CARLY

1)

1)

1)

Connection possibility of oil level controller


make Traxoil

1)

1)

1)

3
1)

Oil sump heater 110-240 V - 1 - 50/60 Hz, 50-120 W


PTC heater, self regulating
Oil sump heater 230 V - 1 - 50/60 Hz, 80 W
Oil charge: Bock C85E
Sight glass
Decompression valve for HP and LP side
Suction and discharge line valve
Inert gas charge
4 anti-vibration pads enclosed
1)

Only possible with additional adapter

96219-02.2012-Gb Subject to change without notice

www.bock.de | 23

CO2 Compressors (subcritical)

Accessories

Accessories

HGX12P CO2

HGX22P CO2

HGX34P CO2

HGX4 CO2

1 Start unloader by means of a Bock ESS (Electronic Soft Start)

IP20 (connection clamps IP00) for installation in switch cabinet


2 Continuously variable speed control by means of a Bock EFC (Electronic Frequency Control), compactly built onto compressor and
connected ready-to-operate HGX12P: IP65 HGX22P/HGX34P: IP54
3 Continuously variable speed control by means of a Bock EFCe

(Electronic Frequency Control for individual installation) IP54


Compressor oil Bock C85E as 1 liter refill unit
4 Oil differential pressure sensor (p-switch Fabrikat make)
220-240 V - 1 - 50/60 Hz
5 Oil service valve
6 Bock Compressor Management BCM2000 including oil pressure

control, oil temperature control (NTC), thermal protection thermostat (PTC) per cylinder cover (only possible ex works)
7 Water-cooled cylinder covers

See water resistant water-cooled cylinder covers


8 Additional fan 220-240 V - 1 - 50/60 Hz,

72/68 W, IP44 enclosed


Additional fan 230 V / 400 V Y - 3 - 50 Hz, 120 W,
230-265 V / 400-460 V Y - 3 - 60 Hz, 190 W,
IP54 enclosed

1)

1)

1)

9 Intermediate adapter for discharge line valve

Adapter for decompression valve


1)

Voltage range 10%


Special voltage and/or frequency (on request)

24 | www.bock.de

96219-02.2012-Gb Subject to change without notice

CO2 Compressors (subcritical)

ESS Electronic Soft Start


1

EFC Electronic Frequency Control


2

Accessories

EFCe Electronic Frequency Control external


3

Oil differential pressure sensor

Oil service valve

BCM2000 Bock Compressor Management

1
2
3
4
Water-cooled cylinder covers

Additional fan

Intermediate adapter for discharge line valve

96219-02.2012-Gb Subject to change without notice

www.bock.de | 25

26 | www.bock.de

96219-02.2012-Gb Subject to change without notice

Bock CO2 compressors


transcritical
At a glance
Operating limits
Performance data
Technical data
Dimensions and connections
Scope of supply and accessories

96219-02.2012-Gb Subject to change without notice

28
32
34
47
48
51

www.bock.de | 27

CO2 Compressors (transcritical)

Since the beginning of the 1990s, GEA Bock, together with leading

At a glance

institutes and manufacturers, has concerned itself with the

The current program of transcritical CO2 compressors was now


extended by the 4-cylinder model HGX34 CO2 T with displace-

development of compressors for the transcritical CO2 process.

ment of 9,9 to 20,1 m3/h.

In the past years, CO2 compressors by GEA Bock could be


established in many areas of application.

CO2 as a refrigerant
Within refrigeration technology, carbon dioxide (CO2) is known by

It is not combustible, is chemically inactive and heavier than air.

the name R744 and has a long history. It is a colourless gas which

Carbon dioxide has a narcotic and asphyxiating effect on humans

liquefies under pressure and has a slightly acidic smell and taste.

only at higher concentrations.

Carbon dioxide has no ozone depletion potential (ODP=0) and a ne-

As carbon dioxide is less energy efficient than other refrigerants,

gligible direct effect on global warming (GWP = 1) when used as a

recently work has particularly concentrated on optimising plant

refrigerant in closed systems.

technology for specific applications. Carbon dioxide is available naturally in large quantities.

Important information
-- Transcritical CO2 applications are still in the development phase
-- They require a completely new kind of system and control
-- They are not a general solution for the substitution of F-gases
-- We specifically point out that all information in this brochure has been made based on our current level of knowledge and may change at any
time due to further development. Legal claims regarding the accuracy of the information cannot be made at any time and are hereby excluded.

-- Compressors can only be made available for selected projects


-- Operation and warranties are subject to a separate agreement

28 | www.bock.de

96219-02.2012-Gb Subject to change without notice

CO2 Compressors (transcritical)

At a glance

Special features
-- High-strength spheroidal cast iron housing for high operating pressures of up to 150 bar on the high pressure side
-- Wear-resistant, long-life mechanism
-- Reliable and safe oil supply through pump lubrication
-- Good operational characteristics through solid total construction
-- Appropriately sized drive motors, available in suction gas-cooled or air-cooled versions, replaceable
-- Suction and discharge connections using compression joints for steel pipes (without shut-off valves)
-- Decompression valves for the suction and discharge area
-- Electrical connection box to IP54 with Bock MP10 motor protection

The current program


...2 model sizes with 10 capacity stages from 6,2 to 20,1 m/h (50 Hz)

1
2
3

Displacement m/h

Type key

HGX34 / 210 - 4 S CO2 T


Transcritical
CO2 Version
Motor variant 2)
Number of poles
Swept volume
Number of cylinders
Size
Ester oil filling
Series
96219-02.2012-Gb Subject to change without notice

1)

1)

HG = Hermetic Gas-cooled (suction gas-cooled)

2)

= More powerful motor

www.bock.de | 29

CO2 Compressors (transcritical)

10

At a glance

12

13

11
8

6
14

Designed for CO2 - built for the future


Bock HG34 CO2 T - A compressor packed with more than 15 years of CO2 compressor experience.
1
2

Oil supply of bearings through forced lubri-

high emergency running properties

In addition, the Bock characteristic features

Piston heads with grooving of the suction

also apply to compressors of the type HG34

Calmed oil level for precise and safe indica-

reed valves outline for minimum clearance

CO2 T

tion of oil level in the sightglas

volume

Prevention against oil overfilling

High-strength spheroidal cast iron housing

10

11

low pressure,- and high pressure side

temperature on the suction side

12

drops and highest efficiency

bearing and optimised mass balance for

13

Highest efficiency through hard chromium

- Easy maintenance
- Frequency converter, variable speed control
of motor
- Bock MP10 electronic motor protection,
especially easy to operate because of status
indicators

Thermal protection thermostat installed ex


works as standard

Weight-optimized connecting rod for highest running comfort

Valve system with optimized flow and channels in the housing ensure lowest pressure

Tempered crankshaft with massive main


highest running comfort

Thermal separations on the cylinder cover


and in the compressor housing improve the

for maximum operating pressures on the

HA design in development

Low oil throw through a calmed lubrication

Hardened pistons with anti-friction coating


at the piston skirt for minimum wear and

circuit, minimum oil foaming and oil mist

cation and optimal oil circulation

14

Oil sump heater installed ex works as


standard

plated piston rings in triple assembly

30 | www.bock.de

96219-02.2012-Gb Subject to change without notice

CO2 Compressors (transcritical)

At a glance

Special features
CO2 transcritical
Based on the high CO2 pressure and the low temperature of the
critical point of 31C (74 bar), transcritical operating conditions occur at higher temperatures at the heat exchanger. In this case, in
comparison to subcritical applications, the refrigerant CO2 can no
longer be condensed. In this case, the refrigerant gas is heated in
a gas cooler. The temperature and the pressure are dependent on
each other, compared to the subcritical operation.
A special feature in these operating points is the necessary regulation of the high pressure at the so-called optimal high pressure. In
doing this, the greatest possible enthalpy difference at the evaporator and the lowest possible power consumption of the compressor
should be reached. In this way, the maximum coefficient of performance (COP) of the system is achieved. An additional valve with

COP
4
3
2
1
0
80

90

100

110

120

tga = 35 C

tga = 45 C

tga = 40 C

tga = 50 C

130

140

150

160 pHD (bar)

1
2

intelligent control after the high-pressure heat exchanger is needed

tga = Gas cooler outlet temperature

for this in the system.

Limit conditions: isentrope compression

For additional technical data see GEA Bock software.

Evaporation pressure = 40 bar with internal heat exchanger

3
4

96219-02.2012-Gb Subject to change without notice

www.bock.de | 31

CO2 Compressors (transcritical)

CO2 Operating limits

Operating limits

HGX2 CO2 T

Unlimited application range


tO

Evaporating temperature (C)

tOh Suction gas superheat (K)


po

Suction pressure (bar)

pV2

Discharge end pressure (bar)

Max. permissible operating pressure (LP/HP)1): 100/150 bar


1)

CO2 Operating limits

LP = low pressure HP = high pressure

HAX2 CO2 T

Unlimited application range


tO

Evaporating temperature (C)

tOh Suction gas superheat (K)


po

Suction pressure (bar)

pV2

Discharge end pressure (bar)

Max. permissible operating pressure (LP/HP)1): 100/150 bar


1)

32 | www.bock.de

LP = low pressure HP = high pressure

96219-02.2012-Gb Subject to change without notice

CO2 Compressors (transcritical)

Operating limits

HGX34 CO2 T

CO2 Operating limits

Unlimited application range


Motor version -S(more powerful motor)
tO

Evaporating temperature (C)

tOh Suction gas superheat (K)


po

Suction pressure (bar)

pV2

Discharge end pressure (bar)

Max. permissible operating pressure (LP/HP)1): 100/150 bar


1)

LP = low pressure HP = high pressure

1
2
3

Co2 Refrigeration oil C85E

Refrigerating-machine oil
40

The compressors are equipped with Bock C85E, a special oil filling,
phase separation

which is available directly from GEA Bock. This is a synthetic ester


oil with high thermal load resistance, allowing good mixing solubility

20

with CO2. It possesses a special additive, which protects the compres-

complete
miscibility

sors against wear, even when subjected to extreme loads, such as those which exist in CO2 systems. This oil can be used both in transcritical
and subcritical systems.

t emperature [C]

-20

-40

20

40

60

concentration [M-%oil in CO2]

CO2 Notes
Operating limits

Performance data

Compressor operation is possible within the limits shown on the

The performance data for CO2 are based on 10 K suctiongas super-

application diagrams. Compressor application limits should not be

heating at 50 Hz mains frequency.

chosen for design purposes or continuous operation.

In case of subcritical operating conditions, no liquid undercooling takes place. The performance data for transcritical operating
conditions are specified close to the "optimal high pressure".
The optimal high pressure is thereby related to an ideal cyclic
process.
Conversion factor for 60 Hz = 1,2

96219-02.2012-Gb Subject to change without notice

www.bock.de | 33

CO2 Compressors (transcritical)

Performance data

CO2

Performance data

50 Hz

Type

Cooling capacity QO [W]

Power consumption Pe [kW]


Evaporating temperature C

15
tC
C
10

HGX2/70-4 CO2 T

15
20
25
30
tga
C
30

35

HGX2/70-4 CO2 T

40

45

50

10

-5

-10

-15

-20

-25

17900
4,11
16500
4,66
14700
5,20
12600
5,72
9970
6,22

14700
4,28
13400
4,75
11900
5,20
10100
5,62
7900
6,03

11900
4,33
10700
4,72
9400
5,08
7870
5,42
6070
5,73

-30

-35

-40

SUBCRITICAL
Q
P
Q
P
Q
P
Q
P
Q
P




23700
19900

4,11
4,45

25200
21300
17900

4,46
4,84
5,09

25700
21900
18500
15400

4,87
5,28
5,56
5,70

24600
21100
17900
15000
12300

5,34
5,79
6,09
6,26
6,30

9320
7160
4,28
4,12
8330
6260
4,58
4,35
7200
5280
4,86
4,55
5920
4210
5,12
4,73
4460
5,35

5310
3,87
4470
4,03
3610
4,16

TRANSCRITICAL
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P

75
30400
5,13
85
27100
6,41
100
26100
8,10
110
23100
9,13
125
21400
10,60

75
26300
5,69
85
23400
6,83
100
22300
8,34
110
19600
9,27
125
18100
10,60

75
22600
6,10
85
20000
7,11
100
18900
8,44
115
17100
9,68
130
15700
10,90

75
19200
6,36
90
17900
7,65
100
15800
8,41
115
14200
9,52
130
12900
10,70

Subcritical performance data 50 Hz


Relative to 10 K suction gas superheat without liquid subcooling

75
16100
6,49
90
14900
7,60
105
13300
8,59
115
11500
9,25
130
10400
10,30

75
13300
6,50
90
12100
7,44
105
10600
8,29
120
9190
9,19
130
8140
9,88

75
75
75
75
10700
8400
6400
4640
6,38
6,16
5,84
5,42
90
90
90
9560
7350
5390
7,17
6,79
6,33
105
100
90
8220
6130
3780
7,89
7,19
6,33
115
100
6960
4550
8,41
7,19
115
5630
8,41

tc = Condensing temperature
tga = Gas cooler outlet temperature
pV2 = Pressure at the compressor outlet [bar]

Transcritical performance data 50 Hz


Relative to 10 K suction gas superheat
The performance data are indicated at a high pressure level, which is
close to an optimal high pressure level. Optimal high pressure is thereby
related to an ideal cyclic process

34 | www.bock.de

Optimal high pressure is outside of the operating limits.


Performance data are indicated at maximal possible high
pressure.

96219-02.2012-Gb Subject to change without notice

CO2 Compressors (transcritical)

Performance data

CO2

Performance data

50 Hz

Type

Cooling capacity QO [W]

Power consumption Pe [kW]


Evaporating temperature C

15
tC
C
10

HAX2/70-4 CO2 T

15
20
25
30
tga
C
30

35

HAX2/70-4 CO2 T

40

45

50

10

-5

-10

-15

-20

-25

-30

-35

-40

SUBCRITICAL
Q
P
Q
P
Q
P
Q
P
Q
P




25000
21100

4,16
4,42

26600
22600
19000

4,48
4,79
4,98

27200 23200
19700
16500

4,84
5,20
5,44
5,56

26500 22700 19300
16300
13600

5,28
5,68
5,96
6,11
6,15

19100
4,09
17600
4,58
15800
5,07
13700
5,58
11300
6,09

15700
4,21
14500
4,64
13000
5,07
11300
5,50
9190
5,94

12800
4,24
11800
4,61
10600
4,98
9090
5,35
7440
5,71

10400
4,19
9490
4,51
8480
4,82
7300
5,12
5970
5,41

8260
4,08
7570
4,34
6750
4,60
5810
4,83
4760
5,06

6570
3,91
6010
4,13
5350
4,32
4600
4,50
3800
4,66

TRANSCRITICAL
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P

75
32000
5,10

75
27700
5,61

75
23800
5,98

75
20300
6,22

75
17200
6,34

75
14400
6,35

75
12000
6,26

75
9840
6,08

75
8010
5,83

75
6440
5,51

75
5110
5,13

80
4020
4,78

85
28200
6,32
100
26500
8,07
110
23100
9,19

85
24300
6,72
100
22700
8,29
110
19900
9,30

85
20900
6,98
100
19400
8,39
110
17000
9,29

90
18800
7,54
100
16500
8,36
110
14500
9,16

90
15800
7,50
105
14200
8,57
115
12800
9,26

90
13200
7,35
105
11900
8,27
115
10800
8,87

90
11000
7,12
105
9750
7,89
115
8910
8,40

90
8910
6,80
105
7910
7,44
115
7270
7,85

90
7170
6,40
110
6420
7,07
115
5770
7,23

95
5640
6,08
110
4890
6,45
110
4120
6,45

95
4250
5,53
100
3490
5,62

95
3020
4,95

110
17300
9,19

110
15000
9,30

110
12900
9,29

110
11100
9,16

115
10400
9,26

115
8680
8,87

115
7210
8,40

115
5880
7,85

115
4670
7,23

Subcritical performance data 50 Hz


Relative to 10 K suction gas superheat without liquid subcooling

tc = Condensing temperature
tga = Gas cooler outlet temperature
pV2 = Pressure at the compressor outlet [bar]

Transcritical performance data 50 Hz


Relative to 10 K suction gas superheat
The performance data are indicated at a high pressure level, which is
close to an optimal high pressure level. Optimal high pressure is thereby
related to an ideal cyclic process

96219-02.2012-Gb Subject to change without notice

Optimal high pressure is outside of the operating limits.


Performance data are indicated at maximal possible high
pressure.

www.bock.de | 35

1
2
3
4

CO2 Compressors (transcritical)

Performance data

CO2

Performance data

50 Hz

Type

Cooling capacity QO [W]

Power consumption Pe [kW]


Evaporating temperature C

15
tC
C
10

HGX2/90-4 CO2 T

15
20
25
30
tga
C
30

35

HGX2/90-4 CO2 T

40

45

50

10

-5

-10

-15

-20

-25

-30

-35

-40

SUBCRITICAL
Q
P
Q
P
Q
P
Q
P
Q
P




30000 25300

5,45
5,82

31900
27200 22900

5,93
6,34
6,61

32600
27900
23700 19800

6,47
6,92
7,23
7,39

31000
26600
22700
19100 15800

7,09
7,57
7,91
8,10
8,16

22800
5,34
21100
6,05
19000
6,74
16400
7,42
12900
8,07

18900
5,51
17400
6,13
15500
6,73
13200
7,30
10400
7,84

15300
5,54
14000
6,08
12400
6,58
10500
7,05
8030
7,47

12200
9460
5,44
5,19
11000
8320
5,88
5,54
9560
7120
6,29
5,85
7960
5820
6,65
6,11
6050
6,96

7120
4,80
6060
5,06
5010
5,28

TRANSCRITICAL
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P

75
37600
6,94
85
33900
8,47
100
32800
10,50
110
28900
11,80
125
26700
13,60

75
32700
7,52
85
29400
8,90
100
28200
10,70
110
24800
11,90
125
22800
13,50

75
28100
7,95
85
25200
9,20
100
24000
10,80
115
21700
12,30
130
20000
13,70

75
24000
8,25
90
22900
9,86
100
20200
10,80
115
18200
12,10
130
16800
13,30

Subcritical performance data 50 Hz


Relative to 10 K suction gas superheat without liquid subcooling

75
20200
8,40
90
19100
9,80
105
17200
10,90
115
15000
11,70
130
13800
12,70

75
16800
8,42
90
15700
9,60
105
13900
10,50
120
12300
11,40
130
11200
12,00

75
75
75
13700
10900
8420
8,29
8,02
7,61
90
90
90
12700
9890
7490
9,26
8,78
8,16
105
100
90
11000
8390
5250
10,00
9,18
8,16
115
100
9420
6220
10,50
9,18
115
7620
10,50

75
6280
7,06
80
3750
7,20

tc = Condensing temperature
tga = Gas cooler outlet temperature
pV2 = Pressure at the compressor outlet [bar]

Transcritical performance data 50 Hz


Relative to 10 K suction gas superheat
The performance data are indicated at a high pressure level, which is
close to an optimal high pressure level. Optimal high pressure is thereby
related to an ideal cyclic process

36 | www.bock.de

Optimal high pressure is outside of the operating limits.


Performance data are indicated at maximal possible high
pressure.

96219-02.2012-Gb Subject to change without notice

CO2 Compressors (transcritical)

Performance data

CO2

Performance data

50 Hz

Type

Cooling capacity QO [W]

Power consumption Pe [kW]


Evaporating temperature C

15
tC
C
10

HAX2/90-4 CO2 T

15
20
25
30
tga
C
30

35

HAX2/90-4 CO2 T

40

45

50

10

-5

-10

-15

-20

-25

-30

-35

24200
5,11
22600
5,78
20500
6,46
17900
7,15
14400
7,85

20300
5,24
18900
5,84
17100
6,45
14900
7,06
11900
7,66

16800
5,25
15600
5,79
14000
6,33
12100
6,85
9670
7,37

13800
5,18
12600
5,65
11300
6,11
9690
6,56
7730
6,98

11100
5,01
9990
5,42
8870
5,81
7580
6,17
6040
6,50

75
15700
8,09
90
14700
9,25
105
13300
10,20
115
11900
10,90
115
9620
10,90

75
12900
7,87
90
12100
8,85
105
10900
9,69
115
9710
10,20
115
7860
10,20

75
10400
7,54
90
9700
8,34
110
8810
9,19
115
7780
9,38
115
6290
9,38

75
75
8250
6380
7,12
6,61
95
95
7770
5940
7,90
7,14
110
100
6860
5020
8,33
7,23
110
100
5770
3700
8,33
7,23
110
4410
8,33

-40

SUBCRITICAL
Q
P
Q
P
Q
P
Q
P
Q
P




31300
26700

5,33
5,62

33300
28600
24400

5,82
6,16
6,37

33900
29300
25100
21300

6,37
6,76
7,01
7,14

32200
27900
24000
20400
17300

7,00
7,43
7,73
7,89
7,93

8690
4,77
7740
5,11
6770
5,42
5750
5,70
4600
5,94

TRANSCRITICAL
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P

75
39200
6,86
85
35100
8,37
100
33700
10,50
110
29900
11,90
110
22400
11,90

75
34400
7,41
85
30700
8,80
100
29300
10,70
110
26000
12,00
110
19600
12,00

75
30000
7,81
85
26700
9,08
100
25400
10,80
110
22400
12,00
110
17100
12,00

75
25900
8,07
90
24500
9,77
100
21800
10,80
110
19200
11,80
110
14700
11,80

Subcritical performance data 50 Hz


Relative to 10 K suction gas superheat without liquid subcooling

75
22100
8,20
90
20900
9,72
105
19100
11,10
115
17000
12,00
115
13800
12,00

75
18700
8,21
90
17600
9,55
105
16000
10,70
115
14300
11,50
115
11600
11,50

80
5000
6,12
95
4360
6,30
95
3520
6,30

tc = Condensing temperature
tga = Gas cooler outlet temperature
pV2 = Pressure at the compressor outlet [bar]

Transcritical performance data 50 Hz


Relative to 10 K suction gas superheat
The performance data are indicated at a high pressure level, which is
close to an optimal high pressure level. Optimal high pressure is thereby
related to an ideal cyclic process

96219-02.2012-Gb Subject to change without notice

Optimal high pressure is outside of the operating limits.


Performance data are indicated at maximal possible high
pressure.

www.bock.de | 37

1
2
3
4

CO2 Compressors (transcritical)

Performance data

CO2

Performance data

50 Hz

Type

Cooling capacity QO [W]

Power consumption Pe [kW]


Evaporating temperature C

15
tC
C
10

HGX2/110-4 CO2 T

15
20
25
30
tga
C
30

35

HGX2/110-4 CO2 T

40

45

50

10

-5

-10

-15

-20

-25

28600
6,75
26500
7,64
23800
8,52
20500
9,37
16200
10,10

23600
6,97
21700
7,75
19500
8,51
16600
9,23
13000
9,91

19200
7,01
17500
7,68
15500
8,31
13100
8,90
10100
9,44

-30

-35

-40

SUBCRITICAL
Q
P
Q
P
Q
P
Q
P
Q
P




37500
31700

6,89
7,36

40000
34100
28700

7,49
8,01
8,35

40800
35000
29700
24900

8,17
8,74
9,13
9,34

38900
33400
28400
23900
19900

8,96
9,56
9,99
10,20
10,30

15300
11900
6,87
6,56
13800
10500
7,43
7,00
12100
8960
7,94
7,40
10100
7330
8,40
7,72
7610
8,80

8940
6,06
7620
6,40
6310
6,67

TRANSCRITICAL
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P

75
47200
8,76
85
42600
10,60
100
41200
13,30
110
36400
14,90
125
33700
17,20

75
41000
9,49
85
36900
11,20
100
35400
13,50
110
31200
15,00
125
28700
17,10

75
35300
10,00
85
31700
11,60
100
30200
13,70
115
27400
15,50
130
25200
17,40

75
30100
10,40
90
28700
12,40
100
25400
13,60
115
22900
15,20
130
21100
16,80

Subcritical performance data 50 Hz


Relative to 10 K suction gas superheat without liquid subcooling

75
25400
10,60
90
24000
12,30
105
21600
13,80
115
18800
14,70
130
17400
16,10

75
21000
10,60
90
19700
12,10
105
17500
13,30
120
15400
14,40
130
14100
15,10

75
75
75
17200
13700
10600
10,40
10,10
9,61
90
90
90
15900
12500
9430
11,60
11,00
10,30
105
100
90
13900
10600
6610
12,60
11,50
10,30
115
100
11900
7830
13,20
11,50
115
9600
13,20

75
7910
8,92
80
4720
9,09

tc = Condensing temperature
tga = Gas cooler outlet temperature
pV2 = Pressure at the compressor outlet [bar]

Transcritical performance data 50 Hz


Relative to 10 K suction gas superheat
The performance data are indicated at a high pressure level, which is
close to an optimal high pressure level. Optimal high pressure is thereby
related to an ideal cyclic process

38 | www.bock.de

Optimal high pressure is outside of the operating limits.


Performance data are indicated at maximal possible high
pressure.

96219-02.2012-Gb Subject to change without notice

CO2 Compressors (transcritical)

Performance data

CO2

Performance data

50 Hz

Type

Cooling capacity QO [W]

Power consumption Pe [kW]


Evaporating temperature C

15
tC
C
10

HAX2/110-4 CO2 T

15
20
25
30
tga
C
30

35

HAX2/110-4 CO2 T

40

45

50

10

-5

-10

-15

-20

-25

-30

-35

-40

30500
6,46
28500
7,31
25900
8,17
22500
9,04
18200
9,92

25600
6,62
23800
7,38
21600
8,15
18700
8,92
15000
9,69

21200
6,64
19600
7,33
17700
8,00
15300
8,67
12200
9,32

17300
6,55
15900
7,15
14300
7,73
12300
8,29
9760
8,83

14000
6,34
12700
6,86
11200
7,35
9580
7,81
7640
8,22

11000
6,03
9780
6,47
8560
6,86
7260
7,22
5810
7,52

75
19700
10,20
90
18500
11,60
105
16800
12,90
115
15100
13,80
115
12200
13,80

75
16300
9,95
90
15200
11,10
105
13700
12,20
115
12300
12,80
115
9940
12,80

75
13200
9,54
90
12300
10,50
110
11200
11,60
115
9840
11,80
115
7960
11,80

75
75
10500 8050
9,00
8,36
95
95
9820
7510
9,98
9,02
110
100
8680
6350
10,50
9,14
110
100
7300
4680
10,50
9,14
110
5580
10,50

SUBCRITICAL
Q
P
Q
P
Q
P
Q
P
Q
P




39500
33700

6,74
7,10

41900 36100
30700

7,36
7,78
8,05

42700
36900 31600
26800

8,05
8,54
8,86
9,02

40600
35200
30200 25800
21800

8,84
9,39
9,76
9,97
10,00

TRANSCRITICAL
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P

75
49500
8,67
85
44200
10,50
100
42500
13,20
110
37700
15,00
110
28200
15,00

75
43400
9,36
85
38700
11,10
100
37000
13,60
110
32700
15,20
110
24700
15,20

75
37800
9,86
85
33600
11,40
100
32000
13,70
110
28300
15,20
110
21500
15,20

75
32600
10,10
90
30900
12,30
100
27400
13,60
110
24300
14,90
110
18500
14,90

Subcritical performance data 50 Hz


Relative to 10 K suction gas superheat without liquid subcooling

75
27900
10,30
90
26400
12,20
105
24000
14,00
115
21500
15,10
115
17400
15,10

75
23600
10,30
90
22200
12,00
105
20200
13,50
115
18100
14,50
115
14700
14,50

80
6310
7,73
95
5520
7,96
95
4450
7,96

tc = Condensing temperature
tga = Gas cooler outlet temperature
pV2 = Pressure at the compressor outlet [bar]

Transcritical performance data 50 Hz


Relative to 10 K suction gas superheat
The performance data are indicated at a high pressure level, which is
close to an optimal high pressure level. Optimal high pressure is thereby
related to an ideal cyclic process

96219-02.2012-Gb Subject to change without notice

Optimal high pressure is outside of the operating limits.


Performance data are indicated at maximal possible high
pressure.

www.bock.de | 39

1
2
3
4

CO2 Compressors (transcritical)

Performance data

CO2

Performance data

50 Hz

Type

Cooling capacity QO [W]

Power consumption Pe [kW]


Evaporating temperature C

15
tC
C
10

HGX34/110-4 CO2 T

15
20
25
30
tga
C
30

35

HGX34/110-4 CO2 T

40

45

50
tC
C
10

HGX34/110-4 S CO2 T

15
20
25
30
tga
C
30

35

HGX34/110-4 S CO2 T

40

45

50

10

-5

-10

-15

-20

-25

-30

-35

30600
6,40
29100
7,17
26800
7,99
23400
8,86
18100
9,75

25800
6,53
24200
7,25
22100
7,99
19200
8,76
14600
9,53

21300
6,57
19800
7,22
17900
7,87
15400
8,52
11600
9,15

17300
13700
6,51
6,33
15800
12200
7,06
6,78
14100
10800
7,61
7,19
12100
9250
8,12
7,54
9140
8,58

75
22500
10,10
90
22000
11,90
105
19600
13,30
110
16500
13,70
110
12600
13,70

75
18600
10,00
90
18100
11,50
105
15800
12,60
110
13200
12,90
110
10100
12,90

75
15200
9,79
90
14600
10,90
100
12400
11,50
100
9150
11,50
100
5900
11,50

75
12100
9,35
85
11000
9,94
85
5470
9,94

75
9400
8,71




39800
34200

6,78
7,01

43100
37300
31900

7,42
7,69
7,89

44400
38600
33100
28100

8,12
8,44
8,68
8,82

41900
36400
31200
26400
22000

8,91
9,28
9,57
9,75
9,82

30600
6,40
29100
7,17
26800
7,99
23400
8,86
18100
9,75

25800
6,53
24200
7,25
22100
7,99
19200
8,76
14600
9,53

21300
6,57
19800
7,22
17900
7,87
15400
8,52
11600
9,15

17300
13700
6,51
6,33
15800
12200
7,06
6,78
14100
10800
7,61
7,19
12100
9250
8,12
7,54
9140
8,58

75
18600
10,00
90
18100
11,50
105
15800
12,60
115
13300
13,10
115
10800
13,10

75
15200
9,79
90
14600
10,90
100
12400
11,50
100
9150
11,50
100
5900
11,50

75
12100
9,35
90
11500
10,10
90
8010
10,10

75
9400
8,71
80
5810
8,91

-40

SUBCRITICAL
Q
P
Q
P
Q
P
Q
P
Q
P




39800
34200

6,78
7,01

43100
37300
31900

7,42
7,69
7,89

38600
33100
28100

8,44
8,68
8,82

31200
26400
22000

9,57
9,75
9,82

10500
6,02
9070
6,34
7970
6,60

TRANSCRITICAL
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P

75
31700
9,98
90
31200
12,00
100
27700
13,40
110
24000
14,60
110
18300
14,60

75
26900
10,10
90
26400
12,00
105
23700
13,80
110
20100
14,30
110
15400
14,30

SUBCRITICAL
Q
P
Q
P
Q
P
Q
P
Q
P

10500
6,02
9070
6,34
7970
6,60

TRANSCRITICAL
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P

75
49200
8,90
85
45100
10,40
100
43800
12,80
110
38500
14,40
125
35400
16,80

75
42800
9,34
85
39200
10,80
100
37900
13,20
110
33200
14,70
125
30500
16,90

75
37000
9,71
85
33900
11,20
100
32500
13,40
115
29300
15,40
130
27400
17,30

75
31700
9,98
90
31200
12,00
100
27700
13,40
115
24700
15,20
130
23300
16,80

Subcritical performance data 50 Hz


Relative to 10 K suction gas superheat without liquid subcooling
Transcritical performance data 50 Hz

75
26900
10,10
90
26400
12,00
105
23700
13,80
115
20600
14,80
130
19500
16,00

75
22500
10,10
90
22000
11,90
105
19600
13,30
120
17100
14,40
130
16000
14,90

tc = Condensing temperature
tga = Gas cooler outlet temperature
pV2 = Pressure at the compressor outlet [bar]

Relative to 10 K suction gas superheat


The performance data are indicated at a high pressure level, which is
close to an optimal high pressure level. Optimal high pressure is thereby
related to an ideal cyclic process

40 | www.bock.de

Optimal high pressure is outside of the operating limits.


Performance data are indicated at maximal possible high
pressure.

96219-02.2012-Gb Subject to change without notice

CO2 Compressors (transcritical)

Performance data

CO2

Performance data

50 Hz

Type

Cooling capacity QO [W]

Power consumption Pe [kW]


Evaporating temperature C

15
tC
C
10

HGX34/130-4 CO2 T

15
20
25
30
tga
C
30

35

HGX34/130-4 CO2 T

40

45

50
tC
C
10

HGX34/130-4 S CO2 T

15
20
25
30
tga
C
30

35

HGX34/130-4 S CO2 T

40

45

50

10

-5

-10

-15

-20

-25

-30

-35





45700
39300

7,78
8,05

49400
42800
36600

8,52
8,83
9,06

44300
38000
32200

9,69
9,97
10,10

35800
30300
25300

10,90
11,20
11,20

35100
7,35
33300
8,24
30800
9,18
26900
10,10
20800
11,20

29600
7,50
27800
8,32
25400
9,18
22000
10,00
16800
10,90

24500
7,55
22700
8,29
20500
9,04
17600
9,78
13400
10,50

19900
15700
7,48
7,27
18100
14000
8,11
7,78
16200
12400
8,73
8,25
13900
10700
9,32
8,66
10500
9,85

75
25900
11,60
90
25300
13,60
105
22500
15,30
110
18900
15,70
110
14500
15,70

75
21400
11,50
90
20800
13,20
105
18100
14,50
110
15100
14,80
110
11600
14,80

75
17400
11,20
90
16800
12,50
100
14200
13,20
100
10600
13,20
100
6780
13,20

75
13900
10,70
85
12600
11,40
85
6280
11,40

75
10800
10,00




45700
39300

7,78
8,05

49400
42800
36600

8,52
8,83
9,06

50900
44300
38000
32200

9,33
9,69
9,97
10,10

48100
41800
35800
30300
25300

10,20
10,60
10,90
11,20
11,20

35100
7,35
33300
8,24
30800
9,18
26900
10,10
20800
11,20

29600
7,50
27800
8,32
25400
9,18
22000
10,00
16800
10,90

24500
7,55
22700
8,29
20500
9,04
17600
9,78
13400
10,50

75
21400
11,50
90
20800
13,20
105
18100
14,50
115
15300
15,10
115
12400
15,10

75
75
17400
13900
11,20
10,70
90
90
16800
13200
12,50
11,60
100
90
14200
9200
13,20
11,60
100
10600
13,20
100
6780
13,20

-40

SUBCRITICAL
Q
P
Q
P
Q
P
Q
P
Q
P

12100
6,91
10500
7,28
9150
7,58

TRANSCRITICAL

pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P

75
36300
11,40
90
35800
13,80
100
31800
15,40
110
27600
16,80
110
21100
16,80

75
30800
11,60
90
30300
13,80
105
27300
15,80
110
23000
16,40
110
17600
16,40

1
2
3
4

SUBCRITICAL
Q
P
Q
P
Q
P
Q
P
Q
P

19900
15700
7,48
7,27
18100
14000
8,11
7,78
16200
12400
8,73
8,25
13900
10700
9,32
8,66
10500
9,85

12100
6,91
10500
7,28
9150
7,58

TRANSCRITICAL
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P

75
56500
10,20
85
51700
12,00
100
50300
14,70
110
44200
16,60
125
40700
19,30

75
49100
10,70
85
45000
12,50
100
43500
15,10
110
38100
16,90
125
35000
19,40

75
42400
11,10
85
38900
12,80
100
37300
15,30
115
33600
17,70
130
31500
19,90

75
36300
11,40
90
35800
13,80
100
31800
15,40
115
28400
17,50
130
26700
19,30

Subcritical performance data 50 Hz


Relative to 10 K suction gas superheat without liquid subcooling
Transcritical performance data 50 Hz

75
30800
11,60
90
30300
13,80
105
27300
15,80
115
23600
17,00
130
22400
18,30

75
25900
11,60
90
25300
13,60
105
22500
15,30
120
19600
16,50
130
18400
17,10

75
10800
10,00
80
6670
10,20

tc = Condensing temperature
tga = Gas cooler outlet temperature
pV2 = Pressure at the compressor outlet [bar]

Relative to 10 K suction gas superheat


The performance data are indicated at a high pressure level, which is
close to an optimal high pressure level. Optimal high pressure is thereby
related to an ideal cyclic process

96219-02.2012-Gb Subject to change without notice

Optimal high pressure is outside of the operating limits.


Performance data are indicated at maximal possible high
pressure.

www.bock.de | 41

CO2 Compressors (transcritical)

Performance data

CO2

Performance data

50 Hz

Type

Cooling capacity QO [W]

Power consumption Pe [kW]


Evaporating temperature C

15
tC
C
10

HGX34/150-4 CO2 T

15
20
25
30
tga
C
30

35

HGX34/150-4 CO2 T

40

45

50
tC
C
10

HGX34/150-4 S CO2 T

15
20
25
30
tga
C
30

35

HGX34/150-4 S CO2 T

40

45

50

10

-5

-10

-15

-20

-25

-30

-35

40000
8,37
37900
9,37
35000
10,40
30600
11,50
23600
12,70

33700
8,54
31600
9,47
28900
10,40
25000
11,40
19100
12,40

27900
8,59
25800
9,43
23400
10,20
20100
11,10
15200
11,90

75
29400
13,30
90
28800
15,50
105
25500
17,40
110
21500
17,90
110
16500
17,90

75
24300
13,10
90
23700
15,00
105
20600
16,50
110
17200
16,80
110
13200
16,80

75
75
19800
15800
12,80
12,20
90
85
19100
14300
14,30
12,90
100
85
16200
7140
15,00
12,90
100
12000
15,00
100
7710
15,00

75
12300
11,30




52000
44700

8,86
9,16

56200
48700
41600

9,69
10,00
10,30

57900
50400
43300
36700

10,60
11,00
11,30
11,50

54700
47500
40800
34500
28800

11,60
12,10
12,50
12,70
12,80

40000
8,37
37900
9,37
35000
10,40
30600
11,50
23600
12,70

33700
8,54
31600
9,47
28900
10,40
25000
11,40
19100
12,40

22600
17900
8,51
8,28
20600
15900
9,23
8,85
18400
14100
9,94
9,39
15800
12100
10,60
9,86
12000
11,20

75
24300
13,10
90
23700
15,00
105
20600
16,50
115
17400
17,10
115
14100
17,10

75
75
19800
15800
12,80
12,20
90
90
19100
15000
14,30
13,20
100
90
16200
10500
15,00
13,20
100
12000
15,00
100
7710
15,00

-40

SUBCRITICAL
Q
P
Q
P
Q
P
Q
P
Q
P




52000
44700

8,86
9,16

56200
48700
41600

9,69
10,00
10,30

50400
43300
36700

11,00
11,30
11,50

40800
34500
28800

12,50
12,70
12,80

22600
17900
8,51
8,28
20600
15900
9,23
8,85
18400
14100
9,94
9,39
15800
12100
10,60
9,86
12000
11,20

13700
7,86
11900
8,28
10500
8,62

TRANSCRITICAL
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P

75
41300
13,00
90
40700
15,80
100
36100
17,50
110
31400
19,10
110
24000
19,10

75
35100
13,20
90
34400
15,70
105
31000
18,00
110
26200
18,70
110
20100
18,70

SUBCRITICAL
Q
P
Q
P
Q
P
Q
P
Q
P

27900
8,59
25800
9,43
23400
10,20
20100
11,10
15200
11,90

13700
7,86
11900
8,28
10500
8,62

TRANSCRITICAL
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P

75
64200
11,60
85
58900
13,60
100
57200
16,80
110
50200
18,90
125
46300
22,00

75
55900
12,20
85
51200
14,20
100
49500
17,20
110
43300
19,20
125
39900
22,10

75
48300
12,60
85
44200
14,60
100
42500
17,50
115
38200
20,20
130
35800
22,60

75
41300
13,00
90
40700
15,80
100
36100
17,50
115
32300
19,90
130
30400
21,90

Subcritical performance data 50 Hz


Relative to 10 K suction gas superheat without liquid subcooling
Transcritical performance data 50 Hz

75
35100
13,20
90
34400
15,70
105
31000
18,00
115
26900
19,30
130
25500
20,90

75
29400
13,30
90
28800
15,50
105
25500
17,40
120
22300
18,80
130
20900
19,40

75
12300
11,30
80
7590
11,60

tc = Condensing temperature
tga = Gas cooler outlet temperature
pV2 = Pressure at the compressor outlet [bar]

Relative to 10 K suction gas superheat


The performance data are indicated at a high pressure level, which is
close to an optimal high pressure level. Optimal high pressure is thereby
related to an ideal cyclic process

42 | www.bock.de

Optimal high pressure is outside of the operating limits.


Performance data are indicated at maximal possible high
pressure.

96219-02.2012-Gb Subject to change without notice

CO2 Compressors (transcritical)

Performance data

CO2

Performance data

50 Hz

Type

Cooling capacity QO [W]

Power consumption Pe [kW]


Evaporating temperature C

15
tC
C
10

HGX34/170-4 CO2 T

15
20
25
30
tga
C
30

35

HGX34/170-4 CO2 T

40

45

50
tC
C
10

HGX34/170-4 S CO2 T

15
20
25
30
tga
C
30

35

HGX34/170-4 S CO2 T

40

45

50

10

-5

-10

-15

-20

-25

-30

-35

45100
9,45
42800
10,50
39500
11,70
34500
13,00
26700
14,30

38000
9,64
35700
10,60
32600
11,70
28200
12,90
21500
14,00

31500
9,70
29100
10,60
26400
11,60
22600
12,50
17100
13,40

75
33200
15,00
90
32500
17,50
105
28800
19,60
110
24300
20,20
110
18600
20,20

75
27500
14,80
90
26700
17,00
105
23200
18,60
110
19400
19,00
110
14900
19,00

75
75
22400
17900
14,40
13,70
90
85
21500
16100
16,10
14,60
100
85
18300
8070
16,90
14,60
100
13500
16,90
100
8710
16,90

75
13900
12,80




58700
50500

10,00
10,30

63500
55000
47000

10,90
11,30
11,60

65400
56900
48900
41400

11,90
12,40
12,80
13,00

61800
53600
46000
39000
32500

13,10
13,70
14,10
14,30
14,40

45100
9,45
42800
10,50
39500
11,70
34500
13,00
26700
14,30

38000
9,64
35700
10,60
32600
11,70
28200
12,90
21500
14,00

25500
20200
9,61
9,34
23200
18000
10,40
10,00
20800
15900
11,20
10,60
17800
13700
11,90
11,10
13500
12,60

75
27500
14,80
90
26700
17,00
105
23200
18,60
115
19600
19,40
115
15900
19,40

75
75
22400
17900
14,40
13,70
90
90
21500
16900
16,10
14,90
100
90
18300
11900
16,90
14,90
100
13500
16,90
100
8710
16,90

-40

SUBCRITICAL
Q
P
Q
P
Q
P
Q
P
Q
P




58700
50500

10,00
10,30

63500
55000
47000

10,90
11,30
11,60

56900
48900
41400

12,40
12,80
13,00

46000
39000
32500

14,10
14,30
14,40

25500
20200
9,61
9,34
23200
18000
10,40
10,00
20800
15900
11,20
10,60
17800
13700
11,90
11,10
13500
12,60

15500
8,88
13400
9,35
11800
9,73

TRANSCRITICAL
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P

75
46700
14,70
90
46000
17,80
100
40800
19,80
110
35400
21,60
110
27000
21,60

75
39600
14,90
90
38900
17,80
105
35000
20,30
110
29600
21,10
110
22600
21,10

1
2
3
4

SUBCRITICAL
Q
P
Q
P
Q
P
Q
P
Q
P

31500
9,70
29100
10,60
26400
11,60
22600
12,50
17100
13,40

15500
8,88
13400
9,35
11800
9,73

TRANSCRITICAL
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P

75
72500
13,10
85
66400
15,40
100
64600
18,90
110
56700
21,30
125
52300
24,90

75
63100
13,70
85
57800
16,00
100
55900
19,40
110
48900
21,70
125
45000
24,90

75
54500
14,30
85
49900
16,50
100
47900
19,70
115
43100
22,80
130
40400
25,50

75
46700
14,70
90
46000
17,80
100
40800
19,80
115
36400
22,50
130
34300
24,80

Subcritical performance data 50 Hz


Relative to 10 K suction gas superheat without liquid subcooling
Transcritical performance data 50 Hz

75
39600
14,90
90
38900
17,80
105
35000
20,30
115
30300
21,80
130
28800
23,60

75
33200
15,00
90
32500
17,50
105
28800
19,60
120
25200
21,20
130
23600
22,00

75
13900
12,80
80
8570
13,10

tc = Condensing temperature
tga = Gas cooler outlet temperature
pV2 = Pressure at the compressor outlet [bar]

Relative to 10 K suction gas superheat


The performance data are indicated at a high pressure level, which is
close to an optimal high pressure level. Optimal high pressure is thereby
related to an ideal cyclic process

96219-02.2012-Gb Subject to change without notice

Optimal high pressure is outside of the operating limits.


Performance data are indicated at maximal possible high
pressure.

www.bock.de | 43

CO2 Compressors (transcritical)

Performance data

CO2

Performance data

50 Hz

Type

Cooling capacity QO [W]

Power consumption Pe [kW]


Evaporating temperature C

15
tC
C
10

HGX34/190-4 CO2 T

15
20
25
30
tga
C
30

35

HGX34/190-4 CO2 T

40

45

50
tC
C
10

HGX34/190-4 S CO2 T

15
20
25
30
tga
C
30

35

HGX34/190-4 S CO2 T

40

45

50

10

-5

-10

-15

-20

-25

-30

-35

50600
10,50
48000
11,80
44300
13,20
38700
14,60
29900
16,10

42600
10,80
40000
11,90
36600
13,20
31600
14,40
24100
15,70

35300
10,80
32700
11,90
29600
13,00
25400
14,00
19200
15,10

75
37200
16,80
90
36400
19,60
105
32300
22,00
110
27200
22,70
110
20900
22,70

75
30800
16,60
90
29900
19,00
105
26000
20,90
110
21700
21,30
110
16700
21,30

75
75
25100
20000
16,20
15,40
90
85
24100
18100
18,10
16,40
100
85
20500
9040
19,00
16,40
100
15200
19,00
100
9760
19,00

75
15600
14,40




65800
56600

11,20
11,60

71200
61700
52700

12,20
12,70
13,00

73300
63800
54800
46400

13,40
13,90
14,30
14,60

69300
60100
51600
43700
36400

14,70
15,30
15,80
16,10
16,20

50600
10,50
48000
11,80
44300
13,20
38700
14,60
29900
16,10

42600
10,80
40000
11,90
36600
13,20
31600
14,40
24100
15,70

28600
22600
10,70
10,40
26000
20100
11,60
11,20
23300
17800
12,50
11,80
19900
15300
13,40
12,40
15200
14,10

75
30800
16,60
90
29900
19,00
105
26000
20,90
115
22000
21,70
115
17800
21,70

75
75
25100
20000
16,20
15,40
90
90
24100
18900
18,10
16,80
100
90
20500
13300
19,00
16,80
100
15200
19,00
100
9760
19,00

-40

SUBCRITICAL
Q
P
Q
P
Q
P
Q
P
Q
P




65800
56600

11,20
11,60

71200
61700
52700

12,20
12,70
13,00

63800
54800
46400

13,90
14,30
14,60

51600
43700
36400

15,80
16,10
16,20

28600
22600
10,70
10,40
26000
20100
11,60
11,20
23300
17800
12,50
11,80
19900
15300
13,40
12,40
15200
14,10

17400
9,95
15000
10,40
13200
10,90

TRANSCRITICAL
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P

75
52300
16,50
90
51500
20,00
100
45700
22,20
110
39700
24,20
110
30300
24,20

75
44400
16,70
90
43600
19,90
105
39200
22,80
110
33200
23,60
110
25400
23,60

SUBCRITICAL
Q
P
Q
P
Q
P
Q
P
Q
P

35300
10,80
32700
11,90
29600
13,00
25400
14,00
19200
15,10

17400
9,95
15000
10,40
13200
10,90

TRANSCRITICAL
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P

75
81300
14,70
85
74500
17,30
100
72400
21,20
110
63600
23,90
125
58600
27,90

75
70700
15,40
85
64800
18,00
100
62600
21,80
110
54800
24,30
125
50500
28,00

75
61100
16,00
85
56000
18,50
100
53700
22,10
115
48300
25,50
130
45300
28,60

75
52300
16,50
90
51500
20,00
100
45700
22,20
115
40800
25,20
130
38500
27,80

Subcritical performance data 50 Hz


Relative to 10 K suction gas superheat without liquid subcooling
Transcritical performance data 50 Hz

75
44400
16,70
90
43600
19,90
105
39200
22,80
115
34000
24,40
130
32200
26,40

75
37200
16,80
90
36400
19,60
105
32300
22,00
120
28200
23,80
130
26400
24,60

75
15600
14,40
80
9610
14,70

tc = Condensing temperature
tga = Gas cooler outlet temperature
pV2 = Pressure at the compressor outlet [bar]

Relative to 10 K suction gas superheat


The performance data are indicated at a high pressure level, which is
close to an optimal high pressure level. Optimal high pressure is thereby
related to an ideal cyclic process

44 | www.bock.de

Optimal high pressure is outside of the operating limits.


Performance data are indicated at maximal possible high
pressure.

96219-02.2012-Gb Subject to change without notice

CO2 Compressors (transcritical)

Performance data

CO2

Performance data

50 Hz

Type

Cooling capacity QO [W]

Power consumption Pe [kW]


Evaporating temperature C

15
tC
C
10

HGX34/210-4 CO2 T

15
20
25
30
tga
C
30

35

HGX34/210-4 CO2 T

40

45

50
tC
C
10

HGX34/210-4 S CO2 T

15
20
25
30
tga
C
30

35

HGX34/210-4 S CO2 T

40

45

50

10

-5

-10

-15

-20

-25

-30

-35

56300
11,80
53500
13,20
49400
14,70
43100
16,30
33300
17,90

47500
12,00
44600
13,30
40800
14,70
35200
16,10
26900
17,50

39300
12,10
36400
13,30
32900
14,50
28300
15,70
21400
16,80

75
41500
18,70
90
40600
21,90
105
36000
24,50
110
30300
25,30
110
23200
25,30

75
34300
18,50
90
33400
21,20
105
29000
23,30
110
24200
23,80
110
18600
23,80

75
75
27900
22300
18,00
17,20
90
85
26900
20100
20,10
18,30
100
85
22800
10100
21,10
18,30
100
16900
21,10
100
10900
21,10

75
17400
16,00




73300
63100

12,40
12,90

79300
68700
58700

13,60
14,10
14,50

81700
71000
61000
51700

14,90
15,50
16,00
16,20

77200
67000
57500
48700
40600

16,40
17,10
17,60
17,90
18,10

56300
11,80
53500
13,20
49400
14,70
43100
16,30
33300
17,90

47500
12,00
44600
13,30
40800
14,70
35200
16,10
26900
17,50

31800
25200
12,00
11,60
29000
22400
13,00
12,40
26000
19900
14,00
13,20
22200
17100
14,90
13,90
16900
15,80

75
34300
18,50
90
33400
21,20
105
29000
23,30
115
24500
24,20
115
19900
24,20

75
75
27900
22300
18,00
17,20
90
90
26900
21100
20,10
18,70
100
90
22800
14800
21,10
18,70
100
16900
21,10
100
10900
21,10

-40

SUBCRITICAL
Q
P
Q
P
Q
P
Q
P
Q
P




73300
63100

12,40
12,90

79300
68700
58700

13,60
14,10
14,50

71000
61000
51700

15,50
16,00
16,20

57500
48700
40600

17,60
17,90
18,10

31800
25200
12,00
11,60
29000
22400
13,00
12,40
26000
19900
14,00
13,20
22200
17100
14,90
13,90
16900
15,80

19400
11,00
16800
11,60
14700
12,10

TRANSCRITICAL
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P

75
58300
18,40
90
57400
22,20
100
50900
24,70
110
44200
27,00
110
33800
27,00

75
49400
18,60
90
48500
22,20
105
43700
25,40
110
37000
26,30
110
28300
26,30

1
2
3
4

SUBCRITICAL
Q
P
Q
P
Q
P
Q
P
Q
P

39300
12,10
36400
13,30
32900
14,50
28300
15,70
21400
16,80

19400
11,00
16800
11,60
14700
12,10

TRANSCRITICAL
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P

75
90600
16,40
85
83000
19,20
100
80700
23,70
110
70800
26,70
125
65300
31,10

75
78800
17,20
85
72200
20,00
100
69800
24,30
110
61100
27,10
125
56200
31,10

75
68100
17,90
85
62400
20,60
100
59900
24,70
115
53900
28,50
130
50500
31,90

75
58300
18,40
90
57400
22,20
100
50900
24,70
115
45500
28,10
130
42900
30,90

Subcritical performance data 50 Hz


Relative to 10 K suction gas superheat without liquid subcooling
Transcritical performance data 50 Hz

75
49400
18,60
90
48500
22,20
105
43700
25,40
115
37900
27,20
130
35900
29,50

75
41500
18,70
90
40600
21,90
105
36000
24,50
120
31400
26,50
130
29500
27,40

75
17400
16,00
80
10700
16,40

tc = Condensing temperature
tga = Gas cooler outlet temperature
pV2 = Pressure at the compressor outlet [bar]

Relative to 10 K suction gas superheat


The performance data are indicated at a high pressure level, which is
close to an optimal high pressure level. Optimal high pressure is thereby
related to an ideal cyclic process

96219-02.2012-Gb Subject to change without notice

Optimal high pressure is outside of the operating limits.


Performance data are indicated at maximal possible high
pressure.

www.bock.de | 45

CO2 Compressors (transcritical)

Performance data

CO2

Performance data

50 Hz

Type

Cooling capacity QO [W]

Power consumption Pe [kW]


Evaporating temperature C

15
tC
C
10

HGX34/230-4 CO2 T

15
20
25
30
tga
C
30

35

HGX34/230-4 CO2 T

40

45

50
tC
C
10

HGX34/230-4 S CO2 T

15
20
25
30
tga
C
30

35

HGX34/230-4 S CO2 T

40

45

50

10

-5

-10

-15

-20

-25

-30

-35

62400
13,00
59300
14,60
54700
16,30
47700
18,00
36900
19,90

52600
13,30
49400
14,80
45100
16,30
39100
17,80
29800
19,40

43500
13,40
40300
14,70
36500
16,00
31300
17,40
23700
18,60

75
45900
20,70
90
44900
24,20
105
39900
27,20
110
33600
28,00
110
25700
28,00

75
38000
20,50
90
37000
23,50
105
32100
25,80
110
26800
26,30
110
20600
26,30

75
75
31000
24700
20,00
19,00
90
85
29800
22300
22,30
20,30
100
85
25200
11200
23,40
20,30
100
18700
23,40
100
12100
23,40

75
19200
17,70




81200
69900

13,80
14,30

87900
76100
65000

15,10
15,70
16,10

90500
78700
67600
57300

16,50
17,20
17,70
18,00

85500
74200
63700
53900
45000

18,10
18,90
19,50
19,90
20,00

62400
13,00
59300
14,60
54700
16,30
47700
18,00
36900
19,90

52600
13,30
49400
14,80
45100
16,30
39100
17,80
29800
19,40

35300
27900
13,30
12,90
32100
24800
14,40
13,80
28800
22000
15,50
14,60
24600
18900
16,50
15,40
18700
17,50

75
38000
20,50
90
37000
23,50
105
32100
25,80
115
27200
26,80
115
22000
26,80

75
75
31000
24700
20,00
19,00
90
90
29800
23400
22,30
20,70
100
90
25200
16400
23,40
20,70
100
18700
23,40
100
12100
23,40

-40

SUBCRITICAL
Q
P
Q
P
Q
P
Q
P
Q
P




81200
69900

13,80
14,30

87900
76100
65000

15,10
15,70
16,10

78700
67600
57300

17,20
17,70
18,00

63700
53900
45000

19,50
19,90
20,00

35300
27900
13,30
12,90
32100
24800
14,40
13,80
28800
22000
15,50
14,60
24600
18900
16,50
15,40
18700
17,50

21400
12,20
18600
12,90
16300
13,40

TRANSCRITICAL
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P

75
64600
20,30
90
63600
24,60
100
56400
27,40
110
49000
29,90
110
37400
29,90

75
54800
20,70
90
53800
24,60
105
48400
28,10
110
40900
29,20
110
31300
29,20

SUBCRITICAL
Q
P
Q
P
Q
P
Q
P
Q
P

43500
13,40
40300
14,70
36500
16,00
31300
17,40
23700
18,60

21400
12,20
18600
12,90
16300
13,40

TRANSCRITICAL
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P

75
101000
18,10
85
91900
21,30
100
89400
26,20
110
78500
29,50
125
72300
34,40

75
87300
19,00
85
80000
22,20
100
77300
26,90
110
67700
30,00
125
62300
34,50

75
75400
19,80
85
69100
22,80
100
66300
27,30
115
59700
31,50
130
55900
35,40

75
64600
20,30
90
63600
24,60
100
56400
27,40
115
50400
31,10
130
47500
34,30

Subcritical performance data 50 Hz


Relative to 10 K suction gas superheat without liquid subcooling
Transcritical performance data 50 Hz

75
54800
20,70
90
53800
24,60
105
48400
28,10
115
41900
30,20
130
39800
32,60

75
45900
20,70
90
44900
24,20
105
39900
27,20
120
34800
29,40
130
32600
30,40

75
19200
17,70
80
11900
18,10

tc = Condensing temperature
tga = Gas cooler outlet temperature
pV2 = Pressure at the compressor outlet [bar]

Relative to 10 K suction gas superheat


The performance data are indicated at a high pressure level, which is
close to an optimal high pressure level. Optimal high pressure is thereby
related to an ideal cyclic process

46 | www.bock.de

Optimal high pressure is outside of the operating limits.


Performance data are indicated at maximal possible high
pressure.

96219-02.2012-Gb Subject to change without notice

CO2 Compressors (transcritical)

Number
of
cylinders

CO2

Type

Displacement
50 / 60 Hz

Technical data

Electrical data
Voltage
1

Max.
working
current
2

m/h

kW

* PW 1+2

HGX2/70-4 CO2 T

HAX2/70-4 CO2 T
HGX2/90-4 CO2 T

Weight

18,5

Connections

Oil
charge

Suction
line
DV

Suction
line
SV

kg

mm

mm

Ltr.

145

18

22

2,5
2,5

Starting
Max.
current
power consumption (rotor locked)
2
2
A
*PW1 / PW 1+2

6,20 / 7,40

11,3

57 / 75

6,20 / 7,40

15,1

9,3

57 / 75

149

18

22

7,70 / 9,30

24,4

14,4

82 / 107

160

18

22

2,5

HAX2/90-4 CO2 T

7,70 / 9,30

20,5

12,0

82 / 107

160

18

22

2,5

HGX2/110-4 CO2 T

9,70 / 11,60

32,2

19,2

110 / 141

160

18

22

2,5

HAX2/110-4 CO2 T

9,70 / 11,60

26,7

15,7

110 / 141

163

18
mm
4

2,5

HGX34/110-4 CO2 T

9,90 / 11,80

24,9

14,7

85 / 110

194

22

22
mm I inch
5
28 I 1 1/8

2,5

HGX34/110-4 S CO2 T

9,90 / 11,80

31,0

17,7

110 / 141

197

22

28 I 1 1/8

2,5

1/
8

2,5

HGX34/130-4 CO2 T

11,30 / 13,60

28,5

16,9

85 / 110

194

22

28 I 1

HGX34/130-4 S CO2 T

11,30 / 13,60

35,3

20,3

110 / 141

197

22

28 I 1 1/8

2,5

HGX34/150-4 CO2 T

12,90 / 15,40

33,5

19,2

110 / 141

197

22

28 I 1 1/8

2,5

22

28 I 1

1/8

2,5

22

28 I 1 1/8

2,5

1/8

2,5

HGX34/150-4 S CO2 T

12,90 / 15,40

39,3

23,1

127 / 158

200

HGX34/170-4 CO2 T

14,50 / 17,40

37,6

21,7

110 / 141

196

HGX34/170-4 S CO2 T

14,50 / 17,40

44,3

26,1

152 / 183

209

22

28 I 1

HGX34/190-4 CO2 T

16,30 / 19,60

41,3

24,3

127 / 158

200

22

28 I 1 1/8

2,5

HGX34/190-4 S CO2 T

16,30 / 19,60

49,6

29,2

152 / 183

209

22

28 I 1 1/8

2,5

HGX34/210-4 CO2 T

18,20 / 21,80

46,0

27,0

152 / 183

200

22

28 I 1 1/8

2,5

HGX34/210-4 S CO2 T

18,20 / 21,80

55,4

32,5

156 / 193

215

22

28 I 1 1/8

2,5

22

28 I 1

1/8

2,5

22

28 I 1 1/8

2,5

HGX34/230-4 CO2 T

20,10 / 24,10

50,9

30,0

152 / 183

209

HGX34/230-4 S CO2 T

20,10 / 24,10

65,5

36,1

191 / 245

217

* PW = Part Winding, motors for part winding start

1 = 1. part winding

2 = 2. part winding

Oil sump heater 110-240 V - 1 - 50/60 Hz (standard)

Fan motor for the HA version 230 V - 1 - 50/60 Hz

PTC heater, 50-120 W, self-regulating

140 W / 0,71 A

Oil sump heater is necessary due to the high CO2 solubility in the oil.

Explanations:
1

Tolerance ( 10%) relates to the mean value of the voltage


range. Other voltages and current types on request.

3 380-420 V Y/YY - 3 - 50 Hz PW
440-480 V Y/YY - 3 - 60 Hz PW
PW = Part Winding, motors for part winding start

- T he specifications for max. power consumption apply for

(no start unloaders required)

50 Hz operation. For 60 Hz operation, the specifications have

- Winding ratios: 70% / 30%

to be multiplied by the factor 1.2.

- Designs for Y/ on request

The max. working current remains unchanged.


- T ake account of the max. operating current / max. power

4 Compression joint for steel pipes

consumption when designing contactors, leads and fuses.


Switches: Service category AC3

96219-02.2012-Gb Subject to change without notice

5 For soldering connections

www.bock.de | 47

1
2
3
4

CO2 Compressors (transcritical)

HGX2 CO2 T

Dimensions and connections

HGX2/70-4 CO2 T

HGX2/90-4 CO2 T

HGX2/110-4 CO2 T

320
134

B2
B1
DV
B

A2

4x

11
210
260
ca.300

555
ca.635

57

HAX2 CO2 T

H
E
F,M

J1

ca.240
370

L1

HAX2/70-4 CO2 T

HAX2/90-4 CO2 T

22

ca.180

262
175

ca.415

SV A1 A

HAX2/110-4 CO2 T

320

A2

134

134

L1

B2

ca.675

Dimensions in mm
Centre of gravity

48 | www.bock.de

F,M
4x

11
210
260
ca.340

22

J1

262
175

ca.415
ca.185
57

ca.245
370

A1
SV
A
H
E
K

B1
DV
B

-- Connections see page 50


-- Dimensions for anti-vibration pad see page 49
96219-02.2012-Gb Subject to change without notice

CO2 Compressors (transcritical)

HGX34/110-4 (S) CO2 T


HGX34/130-4 (S) CO2 T

HGX34 CO2 T

Dimensions and connections

HGX34/150-4 (S) CO2 T HGX34/190-4 (S) CO2 T HGX34/230-4 (S) CO2 T


HGX34/170-4 (S) CO2 T HGX34/210-4 (S) CO2 T

ca.380

DV D1 L1 B2 H

B1 B

150

ca.410
364

7,5
82

Dimensions in ( ) =

F,M

430
595 (545)
ca.715 (665)

B2

B2

O
J1

K
4x

SV
A1
A

12
280
330

1
2
3

HGX34/110-4 CO2 T HGX34/130-4 CO2 T HGX34/150-4 CO2 T HGX34/170-4 CO2 T HGX34/210-4 CO2 T
HGX34/110-4 S CO2 T HGX34/130-4 S CO2 T HGX34/150-4 S CO2 T HGX34/190-4 CO2 T

Dimensions in mm
Centre of gravity

Connections see page 50

b
mm

c
mm

d
mm

HGX2 CO2 T

50

30

M10

25

HAX2 CO2 T

50

30

M10

25

HGX34 CO2 T

50

30

M10

25

a
mm

Type

Dimensions for anti-vibration pad

c
a

96219-02.2012-Gb Subject to change without notice

www.bock.de | 49

CO2 Compressors (transcritical)

Connections

Connections

HGX2 CO2 T / HAX2 CO2 T

SV
DV

Suction line
Discharge line

Connection suction side, not lockable

A1

Connection suction side, lockable

A2

Connection suction side, not lockable

Connection discharge side, not lockable

B1

Connection discharge side, lockable

B2

Connection discharge side, not lockable

D1

Connection oil return from oil separator

Connection oil pressure gauge

HGX34 CO2 T

please refer to Technical data page 47


/16 " UNF

/16 " UNF

/16 " UNF

/16 " UNF

/8 " NPTF

/16 " UNF

/16 " UNF

/8 " NPTF

/8 " NPTF

Oil drain

M22 x 1,5

M22 x 1,5

Oil charge plug

/8 " NPTF

M22 x 1,5

J1

Oil sump heater

15 mm

15 mm

Sight glass

G1"

11/8" - 18 UNEF

L1

Thermal protection thermostat

Oil filter

M22 x 1,5

Connection oil level regulator

50 | www.bock.de

/8 " NPTF

G1"

/16 " UNF


/16 " UNF

/8 " NPTF
/4 " NPTF
/8 " NPTF

/8 " NPTF

M22 x 1,5
1

/2 " NPTF

96219-02.2012-Gb Subject to change without notice

CO2 Compressors (transcritical)

Scope of supply and accessories

Scope of supply

HGX2 CO2 T / HAX2 CO2 T

HGX34 CO2 T

Semi-hermetic two cylinder reciprocating compressor


with drive motor for part winding start 4 pole version
380-420 V Y/YY - 3 - 50 Hz
440-480 V Y/YY - 3 - 60 Hz
Single-section compressor housing
HA Version: Motor is cooled by an integrated fan with air deflection hood
230 V - 1 - 50/60 Hz, 140 W / 0,71 A
Semi-hermetic four cylinder reciprocating compressor
with drive motor for part winding start 4 pole version
380-420 V Y/YY - 3 - 50 Hz
440-480 V Y/YY - 3 - 60 Hz
Single-section compressor housing
Winding protection with PTC resistor sensors and electronic motor pro
tection unit Bock MP10
Thermal protection thermostat (PTC sensor) IP67
Oil sump heater 110-240 V - 1 - 50/60 Hz, 50-120 W
PTC heater, self regulating

Oil charge: Bock C85E 1)

Sight glass
Compressor decompression valve suction and discharge line

Suction and discharge line shut off valve incl. cutting ring version
Decompression valve incl. cutting ring version

Suction line valve with soldered bush


Inert gas charge
4 anti-vibration pads enclosed
1)

Also available as refill unit in 1 liter packaging

Accessories

HGX2 CO2 T / HAX2 CO2 T

HGX34 CO2 T

1 Additional fan 220-240 V - 1 - 50/60 Hz,

72/68 W, IP44 enclosed


2 Suction line valve incl. cutting ring version

96219-02.2012-Gb Subject to change without notice

www.bock.de | 51

52 | www.bock.de

96219-02.2012-Gb Subject to change without notice

Bock CO2 radial piston compressor


RKX transcritical
At a glance
Operating limits
Performance data
Technical data
Dimensions and connections
Scope of supply

96219-02.2012-Gb Subject to change without notice

54
56
57
59
60
61

www.bock.de | 53

Bock CO2 Radial Piston Compressor


RKX (transcritical)

At a glance

Bock RKX CO2 Compressors


GEA Bock has developed this new radial piston compressor with
Obrist Engineering GmbH, who has also worked on the development of CO2 compressors for a long time.
Because of the radial cylinder arrangement on one level and the
combination with CO2 as a working substance, extremely small dimensions can be realized. It is a compressor with future potential
- ideal for small to medium capacities.
The compact engineering design, universal possibilities for installation (vertically or horizontally) as well as the 6-cylinder construction that is radially arranged on one level, result in completely new
dimensions for the working range and potential for development
of the compressor itself (potential operating pressure up to 130
bar).

Important information
-- Transcritical CO2 applications are still in the development phase
-- They require a completely new kind of system and control
-- They are not a general solution for the substitution of F-gases

Type

Displacement 50 Hz

RKX26/31-4 CO2 T

2,7 m/h (1450 rpm)

RKX26/31-2 CO2 T

5,4 m/h (2900 rpm)

-- We specifically point out that all information in this chapter has


been made based on our current level of knowledge and may
change at any time due to further development. Legal claims regarding the accuracy of the information cannot be made at any time
and are hereby excluded.

-- Compressors can only be made available for selected projects

54 | www.bock.de

96219-02.2012-Gb Subject to change without notice

Bock CO2 Radial Piston Compressor


RKX (transcritical)

Special features

Special features
-- Simple total construction, aligned to the special requirements in
the transcritical sector
-- Only two surface seals on the entire compressor (housing cover,
electrical terminal board)
-- Pot-shaped, closed housing made of spheroidal cast iron for
maximum pressure strength
-- Complete power train integrated in the housing, no cylinder
cover required
-- Only a few small high-pressure compartments

Drive
radial piston compressor
RKX26 CO2T

-- Valve operation according to the uniflow principle, the suction


gas is pushed in one direction through the piston and is thus
compressed. There are no alternating gas movements and a

minimum amount of gas pulsation


-- Centrifugal lubrication with integrated oil separation

-- Excellent operating characteristics radial arrangement of six


cylinders on one level

-- Well dimensioned drive motors, partially suction gas cooled, in


2 and 4 pole versions (2.900 and 1.450 rpm)

-- Suction and discharge connections using screwed cutting ring


joints for steel pipes (without shut-off valves)
-- Decompression valves for the suction and pressure area
-- Electrical connection box to IP65 with Bock MP10 motor protection

Type key

RK X 2 6 / 31 - 4 CO2 T
Transcritical
CO2 Version
Number of poles
Swept volume
Number of cylinders
Size
Ester oil filling
Series

96219-02.2012-Gb Subject to change without notice

www.bock.de | 55

Bock CO2 Radial Piston Compressor


RKX (transcritical)

Operating limits

Operating limits

RKX26/31-4 CO2 T 1

RKX26/31-2 CO2 T

pV2 (bar)
140

Unlimited application range

130

120

tO

110

Evaporating temperature (C)

tOh Suction gas superheat (K)

100

? tOh = 10 K

90

p0

Suction pressure (bar)

pV2

High pressure (bar)

80
70

Max. permissible operating pressure (LP/HP)1): 100/150 bar

60
1)

50
40

10
-40

20
-30 -25 -20

30
-10

-5

40
0

50
10

p0 (bar)
t0 (C)

LP = low pressure

HP = high pressure

1 RKX26/31-4 CO2 T min. evaporating temperature


t0 = -5 C (30,4 bar)

15

Notes
Operating limits

Performance data

Compressor operation is possible within the limits shown on the

Performance data for CO2 are based on 10 K suction-gas super-

application diagrams. Compressor application limits should not be

heating at 50 Hz mains frequency. In case of subcritical operating

chosen for design purposes or continuous operation.

conditions, no liquid undercooling takes place. The performance


data for transcritical operating conditions are specified close to the
"optimal high pressure". The optimal high pressure is thereby related to an ideal cyclic process.
Conversion factor for 60 Hz = 1,2

Refrigeration-machine oil
The compressors are equipped with Bock C85E, a special oil filling,
which is available directly from GEA Bock. This is a synthetic ester oil
with high thermal load resistance, allowing good mixing solubility
with CO2. It possesses a special additive, which protects the com-

temperature (C)

Notes
40
30
20

phase separation

pressors against wear, even when subjected to extreme loads, such


as those which exist in CO2 systems. This oil can be used both in
transcritical and subcritical systems.

-20

-40

-55

10

20

40

60

concentration (M-%oil in CO2)

56 | www.bock.de

96219-02.2012-Gb Subject to change without notice

Bock CO2 Radial Piston Compressor


RKX (transcritical)

CO2

Performance data

Performance data

50 Hz

Type

Cooling capacity QO [W]

Power consumption Pe [kW]


Evaporating temperature C

15
tC
C
10

RKX26/31-4 CO2 T

15
20
25
30
tga
C
30
35

RKX26/31-4 CO2 T

40
45
50

10

-5

SUBCRITICAL
Q
P
Q
P
Q
P
Q
P
Q
P




12900

1,86

14000
11600

1,94
2,25

14400
12100
9790

2,02
2,36
2,58

13500
11300
9340
7600

2,12
2,49
2,73
2,85

12000
1,79
10700
2,14
9270
2,43
7740
2,67
6040
2,85

TRANSCRITICAL
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P

75
14300
2,31
85
12500
2,88
100
11600
3,56
110
10100
3,99
125
9130
4,71

75
12000
2,64
85
10500
3,09
100
9600
3,62
110
8240
3,97
125
7460
4,63

Subcritical performance data 50 Hz


Relative to 10 K suction gas superheat without liquid subcooling

75
9840
2,85
85
8570
3,18
100
7770
3,59
115
6750
4,04
130
6170
4,74

75
7920
2,93
90
7190
3,26
100
6120
3,45
115
5200
3,84
125
4510
4,25

75
6200
2,91
90
5540
3,11
105
4610
3,33
110
3800
3,44
110
2910
3,44

tc = Condensing temperature
tga = Gas cooler outlet temperature
pV2 = Pressure at the compressor outlet [bar]

Transcritical performance data 50 Hz


Relative to 10 K suction gas superheat
The performance data are indicated at a high pressure level, which is
close to an optimal high pressure level. Optimal high pressure is thereby
related to an ideal cyclic process

96219-02.2012-Gb Subject to change without notice

Optimal high pressure is outside of the operating limits.


Performance data are indicated at maximal possible
high pressure

www.bock.de | 57

1
2
3
4

Bock CO2 Radial Piston Compressor


RKX (transcritical)

CO2

Performance data

Performance data

50 Hz

Type

Cooling capacity QO [W]

Power consumption Pe [kW]


Evaporating temperature C

15
tC
C
10

RKX26/31-2 CO2 T

15
20
25
30
tga
C
30
35

RKX26/31-2 CO2 T

40
45
50

10

-5

-10

-15

-20

20400
4,47
18500
4,91
16400
5,35
14000
5,79
11000
6,23

16600
4,46
15000
4,86
13200
5,27
11100
5,66
8630
6,05

13300
4,35
11900
4,73
10300
5,10
8540
5,45
6510
5,78

10400
4,15
9120
4,50
7760
4,83
6280
5,14
4620
5,42

75
11600
6,37
90
10500
7,06
105
8900
7,63
110
7430
7,80
110
5680
7,80

75
9020
6,18
90
7890
6,75
95
6350
6,92
95
4040
6,92

75
6740
5,89
85
5530
6,22

75
4720
5,51

SUBCRITICAL
Q
P
Q
P
Q
P
Q
P
Q
P




22500

4,87

24000
20000

5,28
5,35

24600
20700
17100

5,70
5,80
5,83
23500
19900
16600
13700
6,19
6,29
6,34
6,32

TRANSCRITICAL
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P
pV2
Q
P

75
24600
6,41
85
22000
7,18
100
21100
8,25
110
18500
8,95
125
16900
9,98

75
20900
6,50
85
18600
7,19
100
17600
8,15
110
15300
8,75
125
13900
9,65

75
17500
6,53
85
15500
7,14
100
14400
7,98
115
12800
8,76
130
11700
9,51

Subcritical performance data 50 Hz


Relative to 10 K suction gas superheat without liquid subcooling

75
14400
6,49
90
13300
7,28
100
11500
7,75
115
9980
8,40
125
8770
8,80

tc = Condensing temperature
tga = Gas cooler outlet temperature
pV2 = Pressure at the compressor outlet [bar]

Transcritical performance data 50 Hz


Relative to 10 K suction gas superheat
The performance data are indicated at a high pressure level, which is
close to an optimal high pressure level. Optimal high pressure is thereby
related to an ideal cyclic process

58 | www.bock.de

Optimal high pressure is outside of the operating limits.


Performance data are indicated at maximal possible
high pressure

96219-02.2012-Gb Subject to change without notice

Bock CO2 Radial Piston Compressor


RKX (transcritical)

RKX

Electrical data

Number Displacement
of
50 / 60 Hz
Voltage
cylinders
1

Weight

Max.
working
current
2

Max. power
consumption
2

A
/ Y

kW

A
/ Y

m/h

Type

Technical data

Starting
current

Connections 4

Oil
charge

Discharge
line
DV

Suction
line
SV

kg

mm

mm

Ltr.

(rotor locked)

RKX26/31-4 CO2 T

2,70 / 3,30

14,3 / 8,2

5,0

76 / 44

68

12

12

0,6

RKX26/31-2 CO2 T

5,40 / 6,50

40,0 / 23,0

10,6

230 / 133

73

12

12

0,6

Oil sump heater 110-240 V - 1 - 50/60 Hz (standard)


- PTC heater, 50-120 W, self-regulating

ii

Oil sump heater is necessary due to the high CO2 solubility in the oil.

Explanations:
1

Tolerance ( 10%) relates to the mean value of the voltage


range. Other voltages and current types on request
All data are based on the mean value of the voltage range

/ 380-420 V Y - 3 - 50 Hz
265-290 V / 440-480 V Y - 3 - 60 Hz

3 220-240 V

4 Compression joint for steel pipes

- The

specifications for max. power consumption apply for
50Hz operation. For 60Hz operation, the specifications have to
be multiplied by the factor 1.2.
The max. working current remains unchanged.
- T ake account of the max. operating current / max. power consumption when designing contactors, leads and fuses.
Switches: Service category AC3

96219-02.2012-Gb Subject to change without notice

www.bock.de | 59

Bock CO2 Radial Piston Compressor


RKX (transcritical)

Dimensions and connections

RKX26 CO2 T

RKX26/31-4 CO2 T

RKX26/31-2 CO2 T

ca.210
33 33

L1

119

ca.125

B
J1
F

ca.120
107

ca.300

SV

DV

4x

274
ca.440

9
174
202

Centre of gravity

Dimensions in mm

Connections

RKX26 CO2 T

SV
DV

Suction line
Discharge line

Connection suction side, not lockable

Connection discharge side, not lockable

Oil drain

G 1/4 "

Oil charge plug

G 1/4 "

J1

Oil sump heater

15 mm

L1

Thermal protection thermostat

please refer to Technical data page 45


/8 " NPTF
/8 " NPTF

/8 " NPTF

Type

b
mm

c
mm

d
mm

30

30

M8

20

RKX26 CO2 T

a
mm

Dimensions for anti-vibration pad

c
a

60 | www.bock.de

96219-02.2012-Gb Subject to change without notice

Bock CO2 Radial Piston Compressor


RKX (transcritical)

Scope of supply

Scope of supply
Semi-hermetic six cylinder radial piston compressor with drive motor for part winding start 2 or 4 pole version
220-240 V / 380-420 V Y - 3 - 50 Hz
265-290 V / 440-480 V Y - 3 - 60 Hz
Single-section compressor housing hermetically integrated electric motor
Winding protection with PTC resistor sensors and electronic motor protection unit Bock MP10
Thermal protection thermostat (PTC sensor) IP67
Oil sump heater
110-240 V - 1 - 50/60 Hz, 50-120 W
PTC heater, self regulating
Oil charge: Bock C 120E 1)
Sight glass
Compressor decompression valve suction and discharge line
Capability of connecting for suction line and discharge line without shut off valves
Design in cutting ring version for steel pipes

Inert gas charge

4 anti-vibration pads enclosed


1)

Also available as refill unit in 1 or 5 liter packaging

96219-02.2012-Gb Subject to change without notice

www.bock.de | 61

62 | www.bock.de

96219-02.2012-Gb Subject to change without notice

Service - Made by GEA Bock


Training and workshops
GEA Bock on the Internet
Quality by GEA Bock

96219-02.2012-Gb Subject to change without notice

64
65
67
www.bock.de | 63

CO2 Compressors

Service - Made by GEA Bock

Because you're never done learning GEA Bock training and workshops on compressors
Many years ago, GEA Bock intensified its commitment in the area
of customer training.

Overview of training events offered:

And so we offer a comprehensive array of attractive training

- GEA Bock Practitioners' Workshop

events, from two-day practitioners' workshops in Frickenhausen to

- Training tailored to your individual needs

afterwork workshops throughout Germany. Regardless of the type

- Training for your entire staff

of training you are interested in.

- Training on your premises

Three things are characteristic of all GEA Bock training:


- The captivating way that the training director Peter Spies carries
out the events

For additional questions or advice, please contact our training


director:

- The strong practice orientation of the training events, and


- The fact that all training events from, GEA Bock are offered as a free
service

Peter Spies
Telephone +49 70 22 / 94 54-157
Fax +49 70 22 / 94 54-137

Current training dates can be found online at www.bock.de

64 | www.bock.de

Email: Peter.Spies@geagroup.com

96219-02.2012-Gb Subject to change without notice

CO2 Compressors

Service - Made by GEA Bock

Worldwide, Up-to-Date, Comprehensive GEA Bock on the Internet - www.bock.de


Products
-- Comprehensive product brochure
-- Data on all products
-- Dimensions and exploded views
-- Spare parts lists

Sales network
-- Contact persons in over 60 countries
-- Direct link to your trading partner

1
Company

-- Current company information


-- Company film

-- Subsidiaries

-- History
-- References

News
-- Company news
-- Product news
-- Current dates

Toolbocks - The Refrigeration App


-- Power Converter
-- Length Converter
-- Pressure Converter
-- Converter Tube Diameter
-- Refrigerant Calculator
-- Location Finder
-- Error Analysis/Troubleshooter

Wordbock - Translation Tool


-- Available as an app and
-- As an online version on www.bock.de

Know-how
-- Error analysis tool
-- VAP software
-- Comprehensive information
96219-02.2012-Gb Subject to change without notice

www.bock.de | 65

CO2 Compressors

Service - Made by GEA Bock

After Sale Service


GEA Bock offers you individual, personal consultation and
assistance after the purchase as well.
As a customer, GEA Bock always has competent contact people
available to you for technical questions.
Outside our business hours, you can reach us on our
free hotline: 00 800 / 800 000 88
from Monday to Saturday, 8:00 a.m. to 9:00 p.m.

66 | www.bock.de

96219-02.2012-Gb Subject to change without notice

CO2 Compressors

Service - Made by GEA Bock

Quality by GEA Bock The benchmark in cooling and air-conditioning


The name GEA Bock stands worldwide for compressor technology
with the highest level of quality.

Certified quality from GEA Bock

The goal of quality leadership in all product areas has always


been at the centre of our company philosophy in our over 75-year
history.
Today, permanent optimisation of quality, not just on the product
but in all areas, is the core of GEA Bock's company strategy.
GEA Bock meets the requirements of DIN EN ISO 9001:2008, certified through DQS, as well as numerous additional European and
globally recognised standards.

In addition, GEA ock maintains a system of internal company stan-

dards, which go well beyond public regulations in many points.

3
4

96219-02.2012-Gb Subject to change without notice

www.bock.de | 67

Excellence

Passion

Integrity

Responsibility

GEA-versity

GEA Refrigeration Technologies


GEA Bock GmbH
Benzstrae 7, 72636 Frickenhausen, Germany
Phone: +49 7022 9454-0, Fax: +49 7022 9454-137
bock@geagroup.com, www.bock.de

GEA Group AG. All rights reserved. 96219-02.2012-Gb Subject to change without notice Copyright GEA Bock

GEA Group is a global mechanical engineering company with multi-billion euro sales and operations
in more than 50 countries. Founded in 1881, the company is one of the largest providers of
innovative equipment and process technology. GEA Group is listed in the STOXX Europe 600 Index.

Você também pode gostar