Selection Guide
Application Recommended Product(s) In-vitro Diagnostic Use CE Mark Page
Concentrating & Desalting Prior to Electrophoresis Bence-Jones proteins Amicon Ultra-4 Centrifugal Device (10K MWCO) Centricon Centrifugal Devices Minicon and Miniplus Concentrators Oligoclonal banding Centricon Centrifugal Devices Minicon and Miniplus Concentrators Deproteinization ELISpot Assay Amicon Ultra-4 Centrifugal Device (10K MWCO) MultiScreen Filter Plates
4 6 7 6 7
4 8 9
Separating Free from Bound Protein in Microsolute Centrifree Micropartition Device PCR Clean-up
HIV genotyping by DNA sequencing Montage PCR Filter Units Montage PCR96 Micro-well Filter Plate Montage SEQ Cleanup Kit Neonatal Screening PKU screening Clinical Analyzer Feedwater Microbiological QC Testing MultiScreen-HV Filter Plates AFS Water Systems Addi-Chek System HPC and Total Count Samplers and Swab Test Kits
11 11 11 13 14 14 14
SELECTION GUIDE 2
References
1. Christenson, R.H., et al., Clinical Chemistry, 29(6), 1028-1030 (1983). 2. Christenson, R.H. and Russell, M.E., Clinical Chemistry, 31(6), 973 (1985). 3. Gubar, K.T., et al., Clinical Chemistry, 31(6), 973 (1985).
3 C O N C E N T R AT I N G A N D D E SA LT I N G P R I O R T O E L E C T R O P H O R E S I S
Now you can get fast spin times without sacrificing recovery. Only Amicon Ultra filters give you the ultra-high recoveries you expect from an Amicon device (typically >90%) with ultra-fast processing. The high-recovery Ultracel ultrafiltration membrane has broad chemical compatibility. And its sealed in the device using heatnot adhesives, which can result in downstream extractables. The vertical membrane design allows direct pipette sample access, which eliminates the need for a reverse-spin recovery step. The housing design is transparent for easy viewing of concentrate volumes. And its compatible with most rotor types.
35 Mins.
15 Mins.
10 Mins.
Brand V
Brand P
Amicon Ultra-4
C O N C E N T R AT I N G A N D D E SA LT I N G P R I O R T O E L E C T R O P H O R E S I S 4
(continued)
Amicon Ultra-15
Maximum Initial Sample Volume Swinging Bucket Fixed Angle 4 mL 4.0 mL (45 and 35 rotor angles) 3.5 mL (23 rotor angle) Typical Final Concentrate Volume Final Deadstop Volume
Analysis of 20 aliquots of a CSF sample that were identically diluted and then concentrated using an Amicon Ultra-4 device showed a mean albumin percentage and standard deviation of 68.8+1.3 and a coefficient of variance of 1.9%. Analysis of two samples that were not concentrated or diluted showed no statistical difference. (Data courtesy of Helena Laboratories.)
50 L 20 L
200 L 50 L
Maximum Relative Centrifugal Force (x g) Swinging Bucket Fixed Angle 4000 7500* 4000 (3500 for concentrated or viscous solutions)* 5000
Ordering Information
MWCO 8/pk 24/pk 96/pk
Amicon Ultra-4 Centrifugal Devices 5K 10K* 30K 50K 100K UFC8 005 08 UFC8 010 08 UFC8 030 08 UFC8 050 08 UFC8 100 08 UFC8 005 24 UFC8 010 24 UFC8 030 24 UFC8 050 24 UFC8 100 24 UFC8 005 96 UFC8 010 96 UFC8 030 96 UFC8 050 96 UFC8 100 96
U39
1 2 3 4 1
U41
2 3 4
U42
1 2
UFC9 005 08 UFC9 010 08 UFC9 030 08 UFC9 050 08 UFC9 100 08
UFC9 005 24 UFC9 010 24 UFC9 030 24 UFC9 050 24 UFC9 100 24
UFC9 005 96 UFC9 010 96 UFC9 030 96 UFC9 050 96 UFC9 100 96
U45
2 3 4
*In-vitro diagnostic use. Analysis of five groups of urine samples that were identically diluted and then concentrated using an Amicon Ultra-4 device showed a mean albumin percentage and standard deviation of 43.04+1.54. (Data courtesy of Helena Laboratories.)
For Further Information Urine Concentration, Protocol Note, PC1050EN00 Desalting and Buffer Exchange, Application Note, AN1050EN00
5 C O N C E N T R AT I N G A N D D E SA LT I N G P R I O R T O E L E C T R O P H O R E S I S
Centricon filters let you reproducibly concentrate and desalt small volumes (2 mL) of urine, CSF, and other clinical samples usually in less than 60 minutes. The devices feature the low adsorptive Amicon YM membrane for consistent recoveries (typically >95%). Fluid and low molecular weight materials pass into the filtrate cup while proteins are retained and concentrated in the sample reservoir. The driving force for filtration is provided by centrifugation in a fixed angle rotor at 1000 to 5000 x g. Recommended for Detection of Bence-Jones Proteins in CSF Centricon YM-10 devices are recommended for detection of Bence-Jones proteins in CSF, which is an indicator of multiple myeloma. After sample enrichment in the Centricon YM-10 device, immunofixation electrophoresis is used to identify free light chains (Bence Jones proteins) by forming a light chain-antibody complex. Agarose electrophoresis is then used to quantify the light chains and to identify proteins that can be present in tubular diseases such as albumin, 1 globulins, transferrin, and IgG.
Specifications Maximum Initial Sample Volume Typical Final Concentrate Volume Max. Centrifugal Force (YM-10 and 30) 2 mL 2550 L dependent on rotor angle 5,000 x g
Ordering Information
Description* NMWL Qty/Pk Catalogue No.
Centricon YM-10
10K
Centricon YM-30
30K
For Further Information Contact Millipore or visit www.millipore.com/publications Centricon Devices, Data Sheet, PF461EN00 CSF and Urine Concentration, Application Note, AN1000EN00 Desalting with Centricon, Application Note, AN001EN00
C O N C E N T R AT I N G A N D D E SA LT I N G P R I O R T O E L E C T R O P H O R E S I S 6
Static concentrators allow labs that dont have access to a centrifuge to concentrate clinical samples for analysis by electrophoresis or immunoelectrophoresis. Simply add sample to the cells, wait for the sample to be concentrated, and remove the enriched material. Absorbent pads pull the solvent and microsolute through the ultrafilter, concentrating the sample. A treated area near the bottom of each Minicon cell prevents filtration to dryness. The concentrators can be used to concentrate Bence-Jones and other proteins in urine, CSF, or other bodily fluids. They can also be used to enrich serum or plasma or to concentrate enzymes or isoenzymes. Typical performance is 100x concentration in 80 to 120 minutes (Minicon) and 200x concentration in 3 to 4 hours (Miniplus).
Specifications
Minicon B15 Minicon CS15 Minicon A25 Miniplus
NMWL Cell Capacity Cells/Unit Max Concentration Factor Min Recovery Volume Dimensions (mm) WxLxH
Ordering Information
Description Tests/Pk Catalogue No.
(8 x 5) 40 (10 x 5) 50 (8 x 5) 40 (4 x 5) 20
For Further Information Contact Millipore or visit www.millipore.com/publications Minicon/Miniplus, Data Sheet, PF1234EN00
7 C O N C E N T R AT I N G A N D D E SA LT I N G P R I O R T O E L E C T R O P H O R E S I S
ELISpot Assays
MultiScreen Assay Plates
High protein binding capacity with low background staining Reliable sensitivity from lot-to-lot. Tight CVs from plate-to-plate. Available with white plate material, which reduces optical cross-talk when used with imaging systems
1.
Millipore offers three MultiScreen plates designed for ELISpot assays. Each of these sterile, 96-well, filter-bottomed plates provides excellent spot recovery and spot definition. Choose from either styrene or acrylic plate materials. The acrylic is available in clear or white plastic, which reduces optical cross-talk when used with imaging systems. Protocol
2. 3. 4. 5.
1. 2. 3. 4. 5.
Coat membrane with antibodies. Add immune and target cells and incubate Responding cells produce cytokines Wash to remove cells. Add biotinylated antibodies Add avidin-enzyme conjugate Each responding cell produces one spot
Ordering Information
Description Membrane Plate Material (color) Sterility Qty/Pk Catalogue No.
MultiScreen-HA MultiScreen-HV
MF (MCE)
Styrene (clear)
10 10 10
MELI PUN CH
For Further Information Contact Millipore or visit www.millipore.com/publications IFN- ELISpot Assays, Technical Note, TN1075EN00
E L I S P O T A S S AY S 8
Separate free from protein-bound microsolute with a single centrifugal spin. Simply pipette 0.15 to 1 mL of serum, plasma, or other biological sample into the device, place it in the fixed angle rotor of your centrifuge, and spin at 1000 to 2000 x g for 5 to 10 minutes. Protein-bound microsolute and other macromolecules are retained by the 30,000 MWCO membrane. Free microsolute collects in a filtrate cup, ready for analysis or storage. No dilutions or specialized equipment are required. There are no changes in pH, ion composition, or unbound microsolute concentration.13 The devices have been shown to improve accuracy when measuring free ligand concentration, binding capacity, and affinity constants.35 Centrifree is ideal for therapeutic drug monitoring, as well as drug metabolism, free hormone, serotonin, amino acid, free ion and other analyses. In addition, you can conveniently process multiple samples under identical conditions with maximum efficiency. Fast Separation of Free from Bound Microsolute
300
10
20
30
9 S E PA R AT I N G B O U N D V S . F R E E M I C R O S O L U T E
Specifications
Maximum sample volume Minimum sample volume Hold-up volume Maximum centrifugal force Autoclave Rotor compatibility
1.0 mL 0.15 mL 0.01 mL 2000 x g The devices are NOT autoclavable Any fixed-angle rotor that accommodates 17100 mm tubes and is capable of 1000 2000 x g
Ordering Information
Description Qty/Pk Catalogue No.
50
4104
For Further Information Contact Millipore or visit www.millipore.com/publications Centrifree Devices, Data Sheet, PF002EN00 Assay of Free Anticonvulsant Drugs, Application Note, AN1002EN00 Overview of Clinical Guidelines for Monitoring Free Drug Concentration, Application Note, AN1003EN00 Preparing Physiological Samples for Amino Acid Analysis, Application Note, AN100EN00 Centrifree On-line Bibliography, www.millipore.com/publications
References
1. Gilbert, G.A., and Jenkins, R.C., Proc. Roy. Soc. A., 253, 42037 (1959) 2. Paulus, H., Anal. Biochem. 32, 91100 (1969) 3. Sophianopoulos, J.A., et al., Arch. Biochem. Biophys., 187, 1329 (1978) 4. Geiseler, D. and Ritter, M., Clin. Chem., 30, 2832 (1984) 5. Siiteri, P., Science, 223, 191193 (1984)
S E P A R A T I N G B O U N D V S . F R E E M I C R O S O L U T E 10
HIV Genotyping
PCR and Sequencing Cleanup
11 H I V G E N O T Y P I N G
Millipore's unique size-exclusion technology eliminates the use of alcohol, gels, and bind-wash-elute steps. The result: purer DNA, longer read lengths, and higher pass rates. Single-sample PCR Cleanup Montage PCR Filter Units allow you to remove primers and unincorporated dNTPs with a single centrifugal spin. High Throughput PCR Cleanup The Montage PCR96 Micro-well Filter Plate is ideal for high throughput genotyping labs. The micro-well format allows recovery in small volumes, and studies show that recovery of PCR products is 2X greater than other size-exclusion filter plates.* Sequencing Reaction Cleanup Our unique, size-exclusion technology eliminates the need for costly gel filtration resins and bind-wash-elute columns. Montage SEQ cleanup kits increase the amount of useable data from each sequencing reaction by eliminating dye blobs and increasing sequencing read lengths. In addition, theyre optimized for BigDye Terminator and ET Terminator sequencing chemistries.
A 301 bp product specific for the human triglyceride lipase gene (Accession Number M29189) was amplified and the resultant PCR products were purified using the Montage PCR96 plate. Sequencing reactions were cleaned-up using the Montage SEQ kit. Both heterozygote (D1) and homozygote (A2 and B1) examples are shown.
Ordering Information Other 96-well plates and kits are also available. Contact Millipore for additional information.
Description Qty/Pk Catalogue No.
Montage PCR Filter Units Montage PCR96 Filter Plates Montage SEQ Cleanup Kit
UFC7 PCR 50 UFC7 PC2 50 LSKM PCR 10 LSKM PCR 50 LSKS 096 01 LSKS 096 04 LSKS 096 24 SAVM 384 01
*Manifold for use with Montage PCR96 and SEQ products. Montage PCR Filter Units are centrifugal filters.
H I V G E N O T Y P I N G 12
Neonatal Screening
MultiScreen-HV Plate for PKU Screening
High throughput 96-well filter plate format Underdrain prevents leaking during incubation No cross-contamination
The MultiScreen-HV filter plate has an individual Durapore membrane sealed at the bottom of each well to prevent cross-contamination. It also has an underdrain to prevent leakage during incubation. After incubation, eluates are quickly and easily transferred to a microtiter plate using vacuum filtration, which eliminates time-consuming and labor-intensive pipetting. In a published study, the MultiScreen-HV plate was shown to improve the sensitivity of a phenylalanine assay by allowing a larger part of the eluate of the bloodspots to be available to the enzyme reaction (78% as opposed to 40%).1 In addition, the authors note the elimination of a pipetting step, which diminishes the chance of cross-contamination, as well as the removal of fibers from the blotting paper that could interfere in the assay.
Ordering Information
Plate Material (color)
Description
Membrane
Sterility
Qty/Pk
Catalogue
MultiScreen-HV
Durapore (PVDF)
Styrene (clear)
Non-sterile
50
MAHV N45 50
See the back cover for information about syringe filter units for HPLC sample preparation.
References
1 Elvers, L.H., et al, "Phenylketonuria Screening Using the Quantase Phenylalanine Kit in Combination with a Microfilter System and the Dye Tartrazine," Screening 3 (1995) 209223.
13 N E O N A T A L S C R E E N I N G
Microbiological Testing
Admixture Preparations, Water, and Surfaces
The Addi-Chek II Test Kit is designed for use in a statistically valid Quality Assurance (QA) program for microbial analysis of prepared admixtures. The test canister captures and cultures microorganisms that may have been introduced into an admixture from environmental contaminants. Everything needed for quality control testing is included: disposable test canister with bacterially retentive filter, connecting tubes and spikes, and double-peel label.
HPC and Total Count Samplers/Swab Test Kits are self-contained devices that are ideal for monitoring the bacterial quality of surfaces and the water used in dialysate. Theres no media to mix, no agar plates to prepare, nothing to sterilize or clean.
14
Millex filter units are available in a variety of diameters with a choice of membranes, including PVDF, nylon, and hydrophilic or hydrophobic PTFE with low-extractable high density polyethylene (HDPE) housings. Clinical applications for these products include removing particulates and red blood cells for PKU analysis (13 mm Millex units with 0.22 m Durapore PVDF membrane, cat. no. SLGV013NL).
For Further Information Millipore Quick Reference Guide, PB1951EN00 Sample Filtration Prior to Chromatography, TB025EN00