Você está na página 1de 1

5C, 5CP

RoHS

Sun Fuse

, , ,

European Standard 5x20mm HBC Quick Acting Fuse


Functional Characteristics
Testing current
Rating range

100%

25A
500mA 6.3A
8A 20A
500mA 25A
500mA 25A
500mA 15A

150%
210%
275%
400%

500mA 6.3A
8A - 10A
12A 25A

1000%

Blow time limit

Min
Max
4 hours ()
1 hour ()
0.5 hour ()
1800 sec ()
10 ms ()
2 sec ()
3ms()
300ms ()
20ms ()
30ms ()
40ms ()

Marking ()
Sun trademark and approval logos where appropriate, 5C, F, current rating, H and voltage
rating are stamped on the fuse end caps.
20.0+/-0.5mm

5.1+/-0.1mm

5C
1.0mm for 10A and above
0.8mm for 4A to 8A
0.6mm for 3.15A and below
+/- 0.1mm

38+/-2mm

Material ()
Fuse body ceramic tube
End cap nickel plated brass
Pigtail tin plated copper on nickel plated brass cap
Packing ()
Bulk pack of 1000pcs per box (5x200pcs per plastic bag) for 5C and 500pcs for 5CP.

5.5+/-0.1mm
38+/-2mm

21.0+/-0.5mm

RoHS
Comply with EU Directive 2002/95/EC (High melting point solder of over 85% lead content
exempted)

5CP

Reference Information
Current
Rating

(A)
0.500
0.630
0.800
1.0
1.25
1.6
2
2.5
3.15
4
5
6.3
8
10
12
12.5
15
16
20
25
Note () :

Voltage
Rating

(V)
250/400*
250/400*
250/400*
250/400*
250/400*
250/400*
250/400*
250/400*
250/400*
250/400*
250/400*
250/400*
250/400*
250/400*
250/400*
250/400*
250/400*
250/400*
250/400*
250/400*

Avg Cold
Resistance

(ohm)
0.18
0.13
0.10
0.15
0.11
0.075
0.053
0.037
0.029
0.021
0.016
0.012
0.0086
0.0068
0.0049
0.0047
0.0039
0.0036
0.0026
0.0024

Avg V drop

(mV)
106
98
94
170
160
140
120
105
105
99
97
90
86
85
71
70
72
70
68
84

Avg Power
Dissipation

(W)
0.14
0.18
0.23
0.51
0.57
0.66
0.75
0.87
1.00
1.22
1.44
1.74
1.96
2.52
2.70
2.94
4.05
4.32
4.64
4.25

Average I2t
value

(A2sec)
0.4
0.78
1.28
0.53
0.99
1.61
3.39
9.07
13.2
22.5
38.7
68.4
110
242
381
404
612
729
1384
1468

5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP

5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
5C/5CP
-

5C
5C
5C
5C
5C
5C
5C
5C
5C
-

5C
5C
5C
5C
5C
5C
5C

1. The Voltage Drop values are measured at 100% rated current.


2. The Power Dissipation values are measured after testing at 150% rated current for one hour (0.5 hour for 8A 20A) except 25A which are tested at 100% rated
current.
3. The above figures are typical values for reference only and should not be used as acceptance criteria.
4. Please consult factory for availability of other ratings.

* 400V is UL recognized only.

Specifications subject to change without notice