Você está na página 1de 62

2008 SAMSUNG SYSTEM AIR CONDITIONERS

Ver.4

imagine refreshing comforts


2008 Samsung DVM System Air Conditioner will provide you refreshing coolness. Feel the comfort you have never experienced with the cool, refreshing air that Samsungs new DVM PLUS Air Conditioners provides. Experience the maximum comfort in real life. With Samsung, imagination comes to life.
Samsung Electronics Co., LTD.
Head Office (Suwon Korea) 416, Maetan-3Dong, Yeongtong-Gu, Suwon City, Gyeonggi-Do, Korea 443-742 www.dvmsystem.com / Tel : 82-31-200-6421 / Fax : 82-31-200-0938 Ver.4

Big Confidence Global Leading Company >>

London

Moscow Suwon(3) Giheung(3) Yokohama

Beijing Israel Nanjing Suzhou Bangalore

San Jose Dallas

SAMSUNG
Tremendous Investment in R & D
Samsung's thrust on Product Innovation and R&D has given the company a competitive edge in the marketplace. With an investment of over USD 4.59 billion, Samsung operates 16 R&D centers worldwide and employs 27,000 researchers of which 2,500 hold a Ph. D. As a result, Samsung has already applied for 1600 patents in the USA. The focus of the R&D center is to customize electronics products to meet the Specific needs of consumers in that region. Samsung R&D Centers are helping the company to continuously innovate and introduce products customized for todays global market.

SAMSUNG brand equity has reached 16.85 billion USD in 2007


In the Digital era, products are being distinguished by their brand in addition to their functions or quality. In 1999 Samsung Electronics has implemented its global brand communication strategy. Since then, based on the research conducted by Interbrand INC., USA, Samsung Electronics has become one of the fastest growing brands equities from 6.4 billion USD (2001) to over 16.85 billion USD (2007) and is now ranked 21st on Interbrand's Top100 Global Brand List. Samsung has increased its value by emphasizing technology as a life innovator. Samsung will remain close to the customer through its technologies contributing to a higher quality of life.

What is Green Management?


SAMSUNG Electronics' corporate policy of making "Green Management, the top priority of all corporate activities" has led to bold and continuous measures. Such measures include developing green technologies and green products, reducing waste and maintaining accident-free workplaces based on the five pillars of Green Management: Management, Products, Processes, Workplaces and Communities. SAMSUNG is not only making its products more environmentally friendly, but is also building pollution-free workplaces by minimizing the use of harmful substances in processes and developing greener substitutes. With the pursuit of green management, Samsung will continue to create new values as a digital leader in the 21st century.

The Best Global Brands 2007 Report Ranking by Interbrand

2 0 0 8

S a m s u n g

D V M

A i r

C o n d i t i o n e r s

Introduction
02_ Brand Value 06_ Line-up 10_ New Technology

Outdoor Units
18_ DVM PLUS / HR 42_ Mini DVM 46_ Free Joint Multi

Indoor Units
62_ Wall mounted Type 70_ Cassette Type 84_ Duct Type 92_ Floor & Convertible Type 100_ ERV System 104_ Accessories

Control Systems
108_ Integrated Management System 116_ Centralized Control System 118_ Individual Control System 120_ Building Management System 123_ Accessories

imagine
beyond your limit
2008 Samsung DVM System Air Conditioners have all the desirable features you can possibly get. This years outdoor units with new advanced technologies are more powerful and efficient. Stylish indoor units have also become more compact for easier installation. Complete control system helps easier control and adds convenience. Everything is just ahead of your expectation for absolute satisfaction.

06

07

Line-up - Outdoor Units


DVM PLUS III / DVM PLUS III HR
Basic Model
Line up DVM PLUS III DVM PLUS III HR RVXVHT080GE RVXVHT100GE RVXVRT080GE RVXVRT100GE RVXVHT120GE RVXVRT120GE RVXVHT140GE RVXVRT140GE

Samsung DVM Air Conditioners runs with new refrigerant R410A, which will not pollute our global environment.

Mini DVM
4HP 5HP 6HP

High Efficiency Combination


8HP 10HP 12HP 14HP

Line up

DVM PLUS III DVM PLUS III HR

RVXVHT080GE RVXVHT100GE RVXVRT080GE RVXVRT100GE

RVXVHT120GE RVXVRT120GE

RVXVHT140GE RVXVRT140GE

RVXVHT160GE RVXVRT160GE

Compact Combination
8HP 10HP 12HP 14HP 16HP

Free Joint Multi


4.0kW 2 Units 5.0kW 2 Units 6.0kW 3 Units 7.0kW 4 Units 8.0kW 4 Units

Combination Table
High Efficiency Combination
Model
RVXVHT080GE RVXVRT080GE RVXVHT100GE RVXVRT100GE RVXVHT120GE RVXVRT120GE RVXVHT140GE RVXVRT140GE

16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56
2 1 1 2 1 1 3 2 1

1 2
3 2 1 1 2 1 1 1 2 1 1 2 3 1 3 2 1 1 2 2 1 1 2 2 2 1 3 4

Compact Combination
Model
RVXVHT080GE RVXVRT080GE RVXVHT100GE RVXVRT100GE RVXVHT120GE RVXVRT120GE RVXVHT140GE RVXVRT140GE RVXVHT160GE RVXVRT160GE

18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58
1 1 2 1 1 1 1 1 1 2 1 1 2 1 2 3 2 1 1 2 1 1 1 2 1 1 2 3 3 1 1 2 3 1 1 1 2 3 1 1

60

62 64

1 1 3 3 4

08

09

Line-up - Indoor Units


Type KBtu/h kW
7K Btu/h 2.2 kW 9K Btu/h 2.8 kW 12K Btu/h 3.6 kW 15K Btu/h 4.5 kW 18K Btu/h 5.6 kW 21K Btu/h 6.0 kW 24K Btu/h 7.1 kW 30K Btu/h 9.0 kW 36K Btu/h 11.2 kW 44K Btu/h 12.8 kW 48K Btu/h 14.0 kW

MB

Vivace

Neo Forte

Slim 1Way

2Way cassette

Mini 4Way cassette

4Way cassette

Slim Duct

M.S.P Duct

Console

Ceiling

Samsung DVM Air Conditioners runs with new refrigerant R410A, which will not pollute our global environment.

New Technology

10

11

New Technology

imagine
never ending development
See this years new technologies with your own eyes. Never ending development of Samsungs technologies will satisfy all your expectations. Each of this years new technologies were considered to provide you the most efficient and convenient air conditioners. Experience all the newest technologies. Feel the difference.

New Technology

New Technology

12

13

Overview
New DVM Plus III System Air Conditioner has improved its performance with remarkable technologies. We now introduce these notable technologies and how they improved the performance of your air conditioner. Witness the wonderful technologies that makes better world.

New Technology
New Technology

Digital Hybrid System


DHS (Digital Hybrid System) is a brand new concept system composed of DVI compressor, vapor injection technology and turbo intercooler. These 3 factors together provide highly efficient performance.

Fan Guard

DVI Compressor

Vapor Injection

Turbo Intercooler

8 Heat Exchanger Newly Designed G-Fin Turbo Intercooler

DVI Compressor
Efficient and reliable DVI Compressor coupled with Vapor Injection technology has been applied to improve cooling and heating performance and energy efficiency.

Vapor Injection Compressor

Vapor Injection Technology


Improved cooling and heating performance and COP by a new technology of two stage compression. This technology achieved the high heating performance and COP under the lowest temperature, which leads the industry.
q Increase

refrigerant flow rates with a new Vapor Injection technology. Sub-cooling necessary for long piping runs while increasing cooling and heating performance and COP.
Vapor Injection Tube

q Improved

DVI Compressor
DVI (Digital Vapor Injection) compressor injects optimized mid-range pressure refrigerant to improve cooling and heating performance and efficiency.

New G-Fin
High efficiency new G-fin improved heat transfer performance and reinforce corrosion resistance.

Vapor Injection Port

Turbo Intercooler
Turbo intercooler (Shell & Tube Type) improved cooling and heating COP, to secure reliability on long piping installation. Fan Guard
Optimized fan guard design enhanced air flow volume which achieved the high heat transfer performance without increased noise.
q Improve

Turbo Intercooler
Turbo intercooler(Shell and Tube Type) improves cooling and heating COP and secure reliability on long piping installation.

Subcooled liquid refrigerant Low temperature gas refrigerant

COP with the application of Turbo intercooler.

q Adequate

sub-cooling to ensure reliable operation on installations with long piping (200 m).

Temperature

O8 Heat Exchanger
Highly efficient O8 Grooved tube has been applied to reduce pressure loss while increasing heat transfer performance to improve COP.

High

Low temp. liquid refrigerant


Low
New Technology

Saturated liquid refrigerant

2008 SAMSUNG DVM Air Conditioners

New Technology

14

15

New Technology
New Technology

O8 Heat Exchanger and New G-fin


High Efficiency O8 Heat Exchanger
Efficient O8 Grooved tube reduced pressure loss while increasing heat exchange rates to improve COP.
q Groove

Newly Designed Fan Guard


Fan Guard has been optimized to improve air volume and reduce noise and vibration.
q BLDC

shape is designed to be high and slim to increase heat transfer performance inside the tube. DVM PLUS III Competitors Product

Motor, which is 2.7% more efficient than the competitors, has been applied.

q Applied

New Groove Shape (High and Slim)

high static pressure propeller fan and the optimum Bell Mouth form for high external static pressure. (External static pressure: 8mmAq) DVM PLUS III

Item
Diameter Heat transfer surface area Pressure loss in heat Evaporation exchanger Condensation Internal heat transfer performance Pressure resistance

Improved Heat Exchanger


O7 O8 19% 14.1% 10.3% 30.8% same

Conventional Model

New G - Fin
Highly efficiency new G-Fin increased heat transfer performance, reinforced corrosion resistance, and increased operating duration in frost condition.
q Heat

transfer performance improved by 13% compared to the conventional fin, even with the equivalent pressure loss. q Epoxy Acrylic Coating reinforced corrosion resistance. q Heating operation time is 1.4 times longer in frost condition due to new G-Fin. DVM PLUS III (New G-Fin) Conventional (Louver Fin)

G - Fin
EVA. COND temperature(C) Capacity, Power output (W)
60 50 40 30 20 10 0 -10 -20 -30 0 30 60 5000 4000 3000

Wide Louver Fin


Anti corrosive layer Epoxy acrylic Raw aluminum material

Hydrophilic layer Acrylic resin + surfactant

0.3m
2000

2.0m
1000 0 0 30 60 90 120

92m

Time (min.)

Time (min.)

2008 SAMSUNG DVM Air Conditioners

New Technology

Outdoor Units

16

17

Outdoor Units

imagine
the absolute power
New DVM Plus III system air conditioners have become more powerful, efficient and compact. DVM Plus III is equipped with more advanced technologies to provide effective cooling and heating, save energy, and help easier installation. DVM Plus III has capacity up to 64HP with more compact size. Be ready for the new generation of the outdoor unit.
>> 18_ DVM PLUS III / HR >> 42_ Mini DVM >> 46_ Free Joint Multi

Outdoor Units

Outdoor Units - DVM PLUS III / HR

18

19

DVM PLUS III / HR


DVM Plus III/HR offers the largest capacity in the industry with 64HP and boasts the highest COP levels. More compact size, with larger capacity, shows the efficiency of the product. DVM Plus III HR has all the features which DVM Plus III has and offers even more features. DVM Plus III HR will give you simultaneous cooling and heating where different air conditioning is needed under same outdoor unit.

Multi Modular

Technology

Outdoor Units

Line up
Basic Model
Line up DVM PLUS III DVM PLUS III HR RVXVHT080GE RVXVHT100GE RVXVRT080GE RVXVRT100GE RVXVHT120GE RVXVRT120GE RVXVHT140GE RVXVRT140GE

High Efficiency Combinations


8HP 10HP 12HP 14HP

Line up

DVM PLUS III DVM PLUS III HR

RVXVHT080GE RVXVHT100GE RVXVRT080GE RVXVRT100GE

RVXVHT120GE RVXVRT120GE

RVXVHT140GE RVXVRT140GE

RVXVHT160GE RVXVRT160GE

Compact Combinations
8HP 10HP 12HP 14HP 16HP

Combination Table
High Efficiency Combinations
Model
RVXVHT080GE RVXVRT080GE RVXVHT100GE RVXVRT100GE RVXVHT120GE RVXVRT120GE RVXVHT140GE RVXVRT140GE

16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56
2 1 1 2 1 1 3 2 1

1 2
3 2 1 1 2 1 1 1 2 1 1 2 3 1 3 2 1 1 2 2 1 1 2 2 2 1 3 4

Compact Combinations
Model 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58
1 1 2 1 1 1 1 1 1 2 1 1 2 1 2 3 2 1 1 2 1 1 1 2 1 1 2 3 3 1 1 2 3 1 1 1 2 3 3 1 1 1 1 3 4

60

62 64

Comparison to Inverter III


High Efficiency Combinations
DVM PLUS III Company A

RVXVHT080GE RVXVRT080GE RVXVHT100GE RVXVRT100GE RVXVHT120GE RVXVRT120GE

Up to 56HP Only 36HP

DVM PLUS III

Up to 64HP Only 54HP

Compact Combinations

Company A

RVXVHT140GE RVXVRT140GE RVXVHT160GE RVXVRT160GE

2008 SAMSUNG DVM Air Conditioners

Outdoor Units

Outdoor Units - DVM PLUS III / HR

20

21

High COP
High efficiency DVM PLUS III has improved average cooling and heating COP compared to conventional products and achieved the worlds Top Class energy efficiency
q DHS(Digital

Digital Unit Module


8HP
Conventional DVM PLUS III Company A

3.81 4.23 4.15

11%

Digital Unit Module combination enables the system to alternate compressor operation to prolong each compressors life cycle and improves COP with part loads
q

Hybrid System) technology increased refrigerant flow rate and evaporation enthalpy difference. O8 Grooved pipe and G-Fin increased heat exchange efficiency.
18HP
Conventional DVM PLUS III Company A

Control the compressor capacity precisely. long life cycle by alternating operation of the DVI compressors. COP using multiple heat exchangers of outdoor units at part

q Wide q The

3.73 4.10 4.02

10%

q Ensure

DVI Scroll

FVI Scroll

DVI Scroll

FVI Scroll

best BLDC Motor in the industry and Optimum Fan Guard design increased efficiency.

q Improve

loads.

Outdoor Units

A unit

B unit

The Worlds Largest Capacity


Samsung has achieved worlds largest capacity of 64HP by combining maximum 4 outdoor units with 5 different capacities. (8, 10, 12, 14 and 16HP) Many combinations of Heat Pump or Heat Recovery types supporting up to 64 indoor units provide consumers variety of choices for any installation condition.
q q

The Worlds Longest Piping Length

Compact combinations (8~64 HP) : Combination with the model requiring the smallest installation space. High-Efficiency combinations (16~56 HP) : Combination with high-efficiency model.
Conventional Model DVM PLUS III
Height differences between indoor & outdoor units : 50m The longest piping length : 220m (Equivalent Length)

8~48HP

8~64HP

Height difference between indoor units : 15m

The first branch joint to the farthest indoor unit : 45 m (1 Size Up : 90 m)

The Smallest Foot Print Area


The worlds smallest foot print provides smallest installatoin space which saves incredible amount of time.
Conventional Model DVM PLUS III

DVM PLUS III has an actual piping length up to 200m, with the maximum piping length of 45m from the first branch joint to farthest indoor unit, thereby providing more convenience and flexibility for installation in commercial buildings.

Summary
q The

longest piping length : 220m (Equivalent Length) piping length: 1000 m the first branch joint to the farthest indoor unit : 90m (with one piping Size Up)

Space Saving
Model Conventional Model DVM PLUS III Comparison to Conventional Model 12HP 0.92m2 0.67m2 73% 16HP 1.35m2 0.92m2 68%
Approx.

16HP

q Total q From

32%
0.92m2

reduction

1.35m2

8HP

10HP

12HP

14HP

16HP

Conventional Model
27% reduction

32% reduction

DVM PLUS III

2008 SAMSUNG DVM Air Conditioners

Outdoor Units

Outdoor Units - DVM PLUS III / HR

22

23

Free Installation
DVM Plus III/HR provides the degree of freedom from priority of capacity when installing outdoor units in module. DVM PLUS III
8HP (Digital Unit) 14HP (Digital Unit) 10HP (Digital Unit)

Lead-Free and RoHs


8HP

Conventional model
8HP (Fixed Unit) 10HP 14HP (Fixed Unit) (Digital Unit) 14HP

Company A
10HP

Refrigerant Leakage Prevention


To prevent refrigerant leakage, we provide how to diagnose any refrigerant leakage in operation. Also, changing service valves from flange type to brazed type further prevents refrigerant leakage.

>
No limits. A digital outdoor unit with the largest capacity should come last.

>

Outdoor Units

An outdoor unit with the largest capacity should come first.

RoHs Compliance
Although RoHS restriction only applies to small and large household electronics, IT equipment, lightings, power train, toys, leisure and sports equipment, and vending machines. Samsung expands the RoHS restriction into its entire range of products based on its own environmental policies.

External Static Pressure


To respond to a range of various installation environments, DVM PLUS III is designed to be used even in external static pressure of 8 mm Aq.

Lead-Free
DVM Plus III is an eco-friendly product that prevents pollution problems caused by the use of lead, by applying lead-free indoor and outdoor PCBs.

DVM PLUS III HR Versatile Application


As DVM PLUS III HR allows a simultaneous cooling and heating operation with one system, there are variety range of application.
q Great

Heating Cooling Heating


it) Un ge han C de (Mo CU M

Automatic Piping Length Recognition


Auto piping length recognition system saves time with no additional settings and performs the optimum operation in accordance with piping length. Optimal operation by automatic piping length recognition Off On On Off On

for places where simultaneous cooling and heating operation is required. (Hotels, nursing homes, conference rooms, etc.) seasonal air-conditioning which may need a simultaneous cooling and heating operation. case of medium and large office, DVM PLUS III HR satisfies cooling and heating operation simultaneously for the requirements of interior and perimeter zone.

Cooling Heating

q For

q In

Cooling

2008 SAMSUNG DVM Air Conditioners

Outdoor Units

Outdoor Units - DVM PLUS III / HR

24

25

Specification |
Basic Model
Model Power supply Mode *1) Performance

DVM PLUS III / HR

DVM PLUS III DVM PLUS III HR /V/Hz Horse Power HP Capacity Cooling *2) kW Btu/h Heating *3) kW Btu/h Nominal Input Cooling kW Heating kW Circuit Breaker (MCCB/ELB) A Cooling Heating Type/Control Liquid ,mm Gas ,mm Discharge Gas (DVM PLUS III HR) ,mm Oil (Flare) ,mm Installation Max.Length m Limitation Max.Height m Type Factory Charging kg Sound Pressure *4) dB(A) Net Weight DVM PLUS III kg DVM PLUS III HR kg Shipping Weight DVM PLUS III kg DVM PLUS III HR kg Net Dimensions (WxHxD) mm Shipping Dimensions (WxHxD) mm Cooling C Heating C

RVXVHT080GE RVXVRT080GE 3/380~415/50 HP/HR 8 22.4 76,400 25.2 86,000 5.76 5.51 25 3.89 4.57 Propeller/BLDC 9.52 19.05 15.88 200 50 (40) R410A 7.5 57 240 242 253 255 880x1,703x765 948x1,868x832 -5~43 -20~24

RVXVHT100GE RVXVRT100GE 3/380~415/50 HP/HR 10 28.0 95,500 31.5 107,500 7.78 7.16 30 3.60 4.40 Propeller/BLDC 9.52 22.23 19.05 200 50 (40) R410A 7.5 58 240 242 253 255 880x1,703x765 948x1,868x832 -5~43 -20~24

RVXVHT120GE RVXVRT120GE 3/380~415/50 HP/HR 12 33.6 114,600 37.8 129,000 10.40 9.40 40 3.23 4.02 Propeller/BLDC 12.70 25.40 22.23 200 50 (40) R410A 7.5 60 240 242 253 255 880x1,703x765 948x1,868x832 -5~43 -20~24

Model Power supply Mode *1) Performance

DVM PLUS III DVM PLUS III HR /V/Hz Horse Power HP Capacity Cooling *2) kW Btu/h Heating *3) kW Btu/h Nominal Input Cooling kW Heating kW Circuit Breaker (MCCB/ELB) A Cooling Heating Type/Control Liquid ,mm Gas ,mm Discharge Gas (DVM PLUS III HR) ,mm Oil (Flare) ,mm Installation Max.Length m Limitation Max.Height m Type Factory Charging kg Sound Pressure *4) dB(A) Net Weight DVM PLUS III kg DVM PLUS III HR kg Shipping Weight DVM PLUS III kg DVM PLUS III HR kg Net Dimensions (WxHxD) mm Shipping Dimensions (WxHxD) mm Cooling C Heating C

RVXVHT140GE RVXVRT140GE 3/380~415/50 HP/HR 14 39.2 133,800 44.1 150,500 11.00 10.40 40 3.56 4.24 Propeller/BLDC 12.70 25.40 22.23 200 50 (40) R410A 11.0 60 320 323 337 340 1,200x1,703x765 1,268x1,868x832 -5~43 -20~24

RVXVHT160GE RVXVRT160GE 3/380~415/50 HP/HR 16 44.8 152,900 50.4 172,000 14.80 15.00 50 3.03 3.36 Propeller/BLDC 12.70 28.58 22.23 200 50 (40) R410A 11.0 60 320 323 337 340 1,200x1,703x765 1,268x1,868x832 -5~43 -20~24

Outdoor Units

Power

Power

COP Fan Piping Connections

COP Fan Piping Connections

Refrigerant Sound Set Size

Refrigerant Sound Set Size

Operating Temp. Range

Operating Temp. Range

Notes

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. - Specifications are subject to change without prior notice for product improvement.

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. - Specifications are subject to change without prior notice for product improvement.

2008 SAMSUNG DVM Air Conditioners

Outdoor Units

Outdoor Units - DVM PLUS III / HR

26

27

Specification |
Model Basic

DVM PLUS III / HR Module Type - High Efficiency


16HP 18HP 1 1 20HP 2 Model Basic RVXVHT080GE RVXVHT100GE RVXVHT120GE RVXVHT140GE / / / / RVXVRT080GE RVXVRT100GE RVXVRT120GE RVXVRT140GE /V/Hz HP kW Btu/h kW Btu/h kW kW A ,mm ,mm ,mm ,mm m m kg dB(A) kg kg kg kg mm mm C C 22 HP 1 1 3/380~415/50 HP/HR 22 61.6 210,100 69.3 236,500 18.18 16.56 60 3.39 4.18 Propeller/BLDC 15.88 28.58 25.40 6.35 200 50 (40) R410A 7.5x2 62 240x2 242x2 253x2 255x2 (880x1,703x765)x2 (948x1,868x832)x2 -5~43 -20~24 3/380~415/50 HP/HR 24 67.2 229,200 75.6 258,000 17.28 16.53 75 3.89 4.57 Propeller/BLDC 15.88 28.58 25.40 6.35 200 50 (40) R410A 7.5x3 62 240x3 242x3 253x3 255x3 (880x1,703x765)x3 (948x1,868x832)x3 -5~43 -20~24 24 HP 3 26 HP 2 1 2

Module Type - High Efficiency


RVXVHT080GE RVXVHT100GE RVXVHT120GE RVXVHT140GE / / / / RVXVRT080GE RVXVRT100GE RVXVRT120GE RVXVRT140GE /V/Hz HP kW Btu/h kW Btu/h kW kW A ,mm ,mm ,mm ,mm m m kg dB(A) kg kg kg kg mm mm C C

Outdoor Units

Power supply Mode *1) Performance

Horse Power Capacity Cooling *2) Heating *3)

Power

COP Fan Piping Connections

Nominal Input Cooling Heating Circuit Breaker (MCCB/ELB) Cooling Heating Type/Control Liquid Gas Discharge Gas (DVM PLUS III HR) Oil (Flare) Installation Max.Length Limitation Max.Height Type Factory Charging Sound Pressure *4) Net Weight DVM PLUS III DVM PLUS III HR Shipping Weight DVM PLUS III DVM PLUS III HR Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Cooling Heating

Refrigerant Sound Set Size

Operating Temp. Range

3/380~415/50 HP/HR 16 44.8 152,800 50.4 172,000 11.52 11.02 50 3.89 4.57 Propeller/BLDC 12.70 28.58 22.23 6.35 200 50 (40) R410A 7.5x2 60 240x2 242x2 253x2 255x2 (880x1,703x765)x2 (948x1,868x832)x2 -5~43 -20~24

3/380~415/50 HP/HR 18 50.4 171,900 56.7 193,500 13.54 12.67 50 3.72 4.48 Propeller/BLDC 15.88 28.58 25.40 6.35 200 50 (40) R410A 7.5x2 60 240x2 242x2 253x2 255x2 (880x1,703x765)x2 (948x1,868x832)x2 -5~43 -20~24

3/380~415/50 HP/HR 20 56.0 191,000 63.0 215,000 15.56 14.32 60 3.60 4.40 Propeller/BLDC 15.88 28.58 25.40 6.35 200 50 (40) R410A 7.5x2 61 240x2 242x2 253x2 255x2 (880x1,703x765)x2 (948x1,868x832)x2 -5~43 -20~24

Power supply Mode *1) Performance

Horse Power Capacity Cooling *2) Heating *3)

Power

COP Fan Piping Connections

Nominal Input Cooling Heating Circuit Breaker (MCCB/ELB) Cooling Heating Type/Control Liquid Gas Discharge Gas (DVM PLUS III HR) Oil (Flare) Installation Max.Length Limitation Max.Height Type Factory Charging Sound Pressure *4) Net Weight DVM PLUS III DVM PLUS III HR Shipping Weight DVM PLUS III DVM PLUS III HR Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Cooling Heating

Refrigerant Sound Set Size

Operating Temp. Range

3/380~415/50 HP/HR 26 72.8 248,300 81.9 279,500 19.30 18.18 75 3.77 4.50 Propeller/BLDC 19.05 31.75 28.58 6.35 200 50 (40) R410A 7.5x3 63 240x3 242x3 253x3 255x3 (880x1,703x765)x3 (948x1,868x832)x3 -5~43 -20~24

Notes

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. - Specifications are subject to change without prior notice for product improvement.

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. - Specifications are subject to change without prior notice for product improvement.

2008 SAMSUNG DVM Air Conditioners

Outdoor Units

Outdoor Units - DVM PLUS III / HR

28

29

Specification |
Model Basic

DVM PLUS III / HR Module Type - High Efficiency


28 HP 30 HP 3 32 HP 2 1 3/380~415/50 HP/HR 32 89.6 305,600 100.8 344,000 25.96 23.72 100 3.45 4.25 Propeller/BLDC 19.05 31.75 28.58 6.35 200 50 (40) R410A 7.5x3 64 240x3 242x3 253x3 255x3 (880x1,703x765)x3 (948x1,868x832)x3 -5~43 -20~24 Power supply Mode *1) Performance Model Basic RVXVHT080GE RVXVHT100GE RVXVHT120GE RVXVHT140GE / / / / RVXVRT080GE RVXVRT100GE RVXVRT120GE RVXVRT140GE /V/Hz HP kW Btu/h kW Btu/h kW kW A ,mm ,mm ,mm ,mm m m kg dB(A) kg kg kg kg mm mm C C 34 HP 2 1 3/380~415/50 HP/HR 34 95.2 324,800 107.1 365,500 26.56 24.72 100 3.58 4.33 Propeller/BLDC 19.05 31.75 28.58 6.35 200 50 (40) R410A 7.5x2+11x1 64 240x2+320x1 242x2+323x1 253x2+337x1 255x2+340x1 (880x1,703x765)x2+(1,200x1,703x765)x1 (948x1,868x832)x2+(1,268x1,868x832)x1 -5~43 -20~24 36 HP 1 1 1 3/380~415/50 HP/HR 36 100.8 343,900 113.4 387,000 29.18 26.96 100 3.45 4.21 Propeller/BLDC 19.05 38.10 31.75 6.35 200 50 (40) R410A 7.5x2+11x1 64 240x2+320x1 242x2+323x1 253x2+337x1 255x2+340x1 (880x1,703x765)x2+(1,200x1,703x765)x1 (948x1,868x832)x2+(1,268x1,868x832)x1 -5~43 -20~24 38 HP 1 2 3/380~415/50 HP/HR 38 106.4 363,100 119.7 408,500 29.78 27.96 100 3.57 4.28 Propeller/BLDC 19.05 38.10 31.75 6.35 200 50 (40) R410A 7.5x1+11x2 64 240x1+320x2 242x1+323x2 253x1+337x2 255x1+340x2 (880x1,703x765)x1+(1,200x1,703x765)x2 (948x1,868x832)x1+(1,268x1,868x832)x2 -5~43 -20~24 1 2

Module Type - High Efficiency


RVXVHT080GE RVXVHT100GE RVXVHT120GE RVXVHT140GE / / / / RVXVRT080GE RVXVRT100GE RVXVRT120GE RVXVRT140GE /V/Hz HP kW Btu/h kW Btu/h kW kW A ,mm ,mm ,mm ,mm m m kg dB(A) kg kg kg kg mm mm C C

Outdoor Units

Power supply Mode *1) Performance

Horse Power Capacity Cooling *2) Heating *3)

Power

COP Fan Piping Connections

Nominal Input Cooling Heating Circuit Breaker (MCCB/ELB) Cooling Heating Type/Control Liquid Gas Discharge Gas (DVM PLUS III HR) Oil (Flare) Installation Max.Length Limitation Max.Height Type Factory Charging Sound Pressure *4) Net Weight DVM PLUS III DVM PLUS III HR Shipping Weight DVM PLUS III DVM PLUS III HR Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Cooling Heating

Refrigerant Sound Set Size

Operating Temp. Range

3/380~415/50 HP/HR 28 78.4 267,400 88.2 301,000 21.32 19.83 75 3.68 4.45 Propeller/BLDC 19.05 31.75 28.58 6.35 200 50 (40) R410A 7.5x3 63 240x3 242x3 253x3 255x3 (880x1,703x765)x3 (948x1,868x832)x3 -5~43 -20~24

3/380~415/50 HP/HR 30 84.0 286,500 94.5 322,500 23.34 21.48 100 3.60 4.40 Propeller/BLDC 19.05 31.75 28.58 6.35 200 50 (40) R410A 7.5x3 63 240x3 242x3 253x3 255x3 (880x1,703x765)x3 (948x1,868x832)x3 -5~43 -20~24

Horse Power Capacity Cooling *2) Heating *3)

Power

COP Fan Piping Connections

Nominal Input Cooling Heating Circuit Breaker (MCCB/ELB) Cooling Heating Type/Control Liquid Gas Discharge Gas (DVM PLUS III HR) Oil (Flare) Installation Max.Length Limitation Max.Height Type Factory Charging Sound Pressure *4) Net Weight DVM PLUS III DVM PLUS III HR Shipping Weight DVM PLUS III DVM PLUS III HR Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Cooling Heating

Refrigerant Sound Set Size

Operating Temp. Range

Notes

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. - Specifications are subject to change without prior notice for product improvement.

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. - Specifications are subject to change without prior notice for product improvement.

2008 SAMSUNG DVM Air Conditioners

Outdoor Units

Outdoor Units - DVM PLUS III / HR

30

31

Specification |
Model Basic

DVM PLUS III / HR Module Type - High Efficiency


40 HP 42 HP 44 HP 3 1 2 3/380~415/50 HP/HR 40 112.0 382,200 126.0 430,000 32.40 30.20 125 3.46 4.17 Propeller/BLDC 19.05 38.10 31.75 6.35 200 50 (40) R410A 7.5x1+11x2 65 240x1+320x2 242x1+323x2 253x1+337x2 255x1+340x2 (880x1,703x765)x1+(1,200x1,703x765)x2 (948x1,868x832)x1+(1,268x1,868x832)x2 -5~43 -20~24 3 3/380~415/50 HP/HR 42 117.6 401,400 132.3 451,500 33.00 31.20 125 3.56 4.24 Propeller/BLDC 19.05 38.10 31.75 6.35 200 50 (40) R410A 11x3 65 320x3 323x3 337x3 340x3 (1,200x1,703x765)x3 (1,268x1,868x832)x3 -5~43 -20~24 1 3/380~415/50 HP/HR 44 123.2 420,300 138.6 473,000 34.34 31.88 125 3.59 4.35 Propeller/BLDC 19.05 38.10 31.75 6.35 200 50 (40) R410A 7.5x3+11x1 65 240x3+320x1 242x3+323x1 253x3+337x1 255x3+340x1 (880x1,703x765)x3+(1,200x1,703x765)x1 (948x1,868x832)x3+(1,268x1,868x832)x1 -5~43 -20~24 Model Basic RVXVHT080GE RVXVHT100GE RVXVHT120GE RVXVHT140GE / / / / RVXVRT080GE RVXVRT100GE RVXVRT120GE RVXVRT140GE /V/Hz HP kW Btu/h kW Btu/h kW kW A ,mm ,mm ,mm ,mm m m kg dB(A) kg kg kg kg mm mm C C 46 HP 2 1 1 3/380~415/50 HP/HR 46 128.8 439,400 144.9 494,500 36.96 34.12 125 3.48 4.25 Propeller/BLDC 19.05 38.10 31.75 6.35 200 50 (40) R410A 7.5x3+11x1 65 240x3+320x1 242x3+323x1 253x3+337x1 255x3+340x1 (880x1,703x765)x3+(1,200x1,703x765)x1 (948x1,868x832)x3+(1,268x1,868x832)x1 -5~43 -20~24 48 HP 2 2 3/380~415/50 HP/HR 48 134.4 458,600 151.2 516,000 37.56 35.12 125 3.58 4.31 Propeller/BLDC 19.05 38.10 31.75 6.35 200 50 (40) R410A 7.5x2+11x2 65 240x2+320x2 242x2+323x2 253x2+337x2 255x2+340x2 (880x1,703x765)x2+(1,200x1,703x765)x2 (948x1,868x832)x2+(1,268x1,868x832)x2 -5~43 -20~24 50 HP 1 1 2 3/380~415/50 HP/HR 50 140.0 477,700 157.5 537,500 40.18 37.36 150 3.48 4.22 Propeller/BLDC 22.23 44.50 38.10 6.35 200 50 (40) R410A 7.5x2+11x2 66 240x2+320x2 242x2+323x2 253x2+337x2 255x2+340x2 (880x1,703x765)x2+(1,200x1,703x765)x2 (948x1,868x832)x2+(1,268x1,868x832)x2 -5~43 -20~24

Module Type - High Efficiency


RVXVHT080GE RVXVHT100GE RVXVHT120GE RVXVHT140GE / / / / RVXVRT080GE RVXVRT100GE RVXVRT120GE RVXVRT140GE /V/Hz HP kW Btu/h kW Btu/h kW kW A ,mm ,mm ,mm ,mm m m kg dB(A) kg kg kg kg mm mm C C

Outdoor Units

Power supply Mode *1) Performance

Horse Power Capacity Cooling *2) Heating *3)

Power supply Mode *1) Performance

Horse Power Capacity Cooling *2) Heating *3)

Power

COP Fan Piping Connections

Nominal Input Cooling Heating Circuit Breaker (MCCB/ELB) Cooling Heating Type/Control Liquid Gas Discharge Gas (DVM PLUS III HR) Oil (Flare) Installation Max.Length Limitation Max.Height Type Factory Charging Sound Pressure *4) Net Weight DVM PLUS III DVM PLUS III HR Shipping Weight DVM PLUS III DVM PLUS III HR Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Cooling Heating

Power

COP Fan Piping Connections

Nominal Input Cooling Heating Circuit Breaker (MCCB/ELB) Cooling Heating Type/Control Liquid Gas Discharge Gas (DVM PLUS III HR) Oil (Flare) Installation Max.Length Limitation Max.Height Type Factory Charging Sound Pressure *4) Net Weight DVM PLUS III DVM PLUS III HR Shipping Weight DVM PLUS III DVM PLUS III HR Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Cooling Heating

Refrigerant Sound Set Size

Refrigerant Sound Set Size

Operating Temp. Range

Operating Temp. Range

Notes

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. - Specifications are subject to change without prior notice for product improvement.

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. - Specifications are subject to change without prior notice for product improvement.

2008 SAMSUNG DVM Air Conditioners

Outdoor Units

Outdoor Units - DVM PLUS III / HR

32

33

Specification |
Model Basic

DVM PLUS III / HR Module Type - Compact


52 HP 54 HP 56 HP Model Basic 2 2 3/380~415/50 HP/HR 52 145.6 496,800 163.8 559,000 42.80 39.60 150 3.40 4.14 Propeller/BLDC 22.23 44.50 38.10 6.35 200 50 (40) R410A 7.5x2+11x2 66 240x2+320x2 242x2+323x2 253x2+337x2 255x2+340x2 (880x1,703x765)x2+(1,200x1,703x765)x2 (948x1,868x832)x2+(1,268x1,868x832)x2 -5~43 -20~24 1 3 3/380~415/50 HP/HR 54 151.2 516,000 170.1 580,500 43.40 40.60 150 3.48 4.19 Propeller/BLDC 22.23 44.50 38.10 6.35 200 50 (40) R410A 7.5x1+11x3 66 240x1+320x3 242x1+323x3 253x1+337x3 255x1+340x3 (880x1,703x765)x1+(1,200x1,703x765)x3 (948x1,868x832)x1+(1,268x1,868x832)x3 -5~43 -20~24 RVXVHT080GE RVXVHT100GE RVXVHT120GE RVXVHT140GE RVXVHT160GE / / / / / RVXVRT080GE RVXVRT100GE RVXVRT120GE RVXVRT140GE RVXVRT160GE /V/Hz HP kW Btu/h kW Btu/h kW kW A ,mm ,mm ,mm ,mm m m kg dB(A) kg kg kg kg mm mm C C 18 HP 1 1 20 HP 2 22 HP 1 1

Module Type - High Efficiency


RVXVHT080GE RVXVHT100GE RVXVHT120GE RVXVHT140GE / / / / RVXVRT080GE RVXVRT100GE RVXVRT120GE RVXVRT140GE /V/Hz HP kW Btu/h kW Btu/h kW kW A ,mm ,mm ,mm ,mm m m kg dB(A) kg kg kg kg mm mm C C

Power supply Mode *1) Performance

Horse Power Capacity Cooling *2) Heating *3)

Power

COP Fan Piping Connections

Nominal Input Cooling Heating Circuit Breaker (MCCB/ELB) Cooling Heating Type/Control Liquid Gas Discharge Gas (DVM PLUS III HR) Oil (Flare) Installation Max.Length Limitation Max.Height Type Factory Charging Sound Pressure *4) Net Weight DVM PLUS III DVM PLUS III HR Shipping Weight DVM PLUS III DVM PLUS III HR Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Cooling Heating

4 3/380~415/50 HP/HR 56 156.8 535,200 176.4 602,000 44.00 41.60 150 3.56 4.24 Propeller/BLDC 22.23 44.50 38.10 6.35 200 50 (40) R410A 11x4 66 320x4 323x4 337x4 340x4 (1,200x1,703x765)x4 (1,268x1,868x832)x4 -5~43 -20~24

Outdoor Units

Power supply Mode *1) Performance

Horse Power Capacity Cooling *2) Heating *3)

Power

COP Fan Piping Connections

Refrigerant Sound Set Size

Refrigerant Sound Set Size

Nominal Input Cooling Heating Circuit Breaker (MCCB/ELB) Cooling Heating Type/Control Liquid Gas Discharge Gas (DVM PLUS III HR) Oil (Flare) Installation Max.Length Limitation Max.Height Type Factory Charging Sound Pressure *4) Net Weight DVM PLUS III DVM PLUS III HR Shipping Weight DVM PLUS III DVM PLUS III HR Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Cooling Heating

Operating Temp. Range

Operating Temp. Range

3/380~415/50 HP/HR 18 50.4 171,900 56.7 193,500 13.54 12.67 50 3.72 4.48 Propeller/BLDC 15.88 28.58 25.40 6.35 200 50 (40) R410A 7.5x2 60 240x2 242x2 253x2 255x2 (880x1,703x765)x2 (948x1,868x832)x2 -5~43 -20~24

3/380~415/50 HP/HR 20 56.0 191,000 63.0 215,000 15.56 14.32 60 3.60 4.40 Propeller/BLDC 15.88 28.58 25.40 6.35 200 50 (40) R410A 7.5x2 61 240x2 242x2 253x2 255x2 (880x1,703x765)x2 (948x1,868x832)x2 -5~43 -20~24

3/380~415/50 HP/HR 22 61.6 210,100 69.3 236,500 18.18 16.56 60 3.39 4.18 Propeller/BLDC 15.88 28.58 25.40 6.35 200 50 (40) R410A 7.5x2 62 240x2 242x2 253x2 255x2 (880x1,703x765)x2 (948x1,868x832)x2 -5~43 -20~24

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. - Specifications are subject to change without prior notice for product improvement.

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. - Specifications are subject to change without prior notice for product improvement.

2008 SAMSUNG DVM Air Conditioners

Outdoor Units

Outdoor Units - DVM PLUS III / HR

34

35

Specification |
Model Basic

DVM PLUS III / HR Module Type - Compact


24 HP 26 HP 28 HP Model Basic 1 1 3/380~415/50 HP/HR 24 67.2 229,300 75.6 258,000 18.78 17.56 75 3.58 4.31 Propeller/BLDC 15.88 28.58 25.40 6.35 200 50 (40) R410A 7.5x1+11x1 62 240x1+320x1 242x1+323x1 253x1+337x1 255x1+340x1 (880x1,703x765)x1+(1,200x1,703x765)x1 (948x1,868x832)x1+(1,268x1,868x832)x1 -5~43 -20~24 1 1 3/380~415/50 HP/HR 26 72.8 248,400 81.9 279,500 21.40 19.80 75 3.40 4.14 Propeller/BLDC 19.05 31.75 28.58 6.35 200 50 (40) R410A 7.5x1+11x1 62 240x1+320x1 242x1+323x1 253x1+337x1 255x1+340x1 (880x1,703x765)x1+(1,200x1,703x765)x1 (948x1,868x832)x1+(1,268x1,868x832)x1 -5~43 -20~24 2 3/380~415/50 HP/HR 28 78.4 267,600 88.2 301,000 22.00 20.80 75 3.56 4.24 Propeller/BLDC 19.05 31.75 28.58 6.35 200 50 (40) R410A 11x2 63 320x2 323x2 337x2 340x2 (1,200x1,703x765)x2 (1,268x1,868x832)x2 -5~43 -20~24 Power supply Mode *1) Performance RVXVHT080GE RVXVHT100GE RVXVHT120GE RVXVHT140GE RVXVHT160GE / / / / / RVXVRT080GE RVXVRT100GE RVXVRT120GE RVXVRT140GE RVXVRT160GE /V/Hz HP kW Btu/h kW Btu/h kW kW A ,mm ,mm ,mm ,mm m m kg dB(A) kg kg kg kg mm mm C C 30 HP 32 HP 34 HP 1 2 1 1 3/380~415/50 HP/HR 30 84.0 286,700 94.5 322,500 25.80 25.40 100 3.26 3.72 Propeller/BLDC 19.05 31.75 28.58 6.35 200 50 (40) R410A 11x2 63 320x2 323x2 337x2 340x2 (1,200x1,703x765)x2 (1,268x1,868x832)x2 -5~43 -20~24 / / / / / RVXVRT080GE RVXVRT100GE RVXVRT120GE RVXVRT140GE RVXVRT160GE /V/Hz HP kW Btu/h kW Btu/h kW kW A ,mm ,mm ,mm ,mm m m kg dB(A) kg kg kg kg mm mm C C

Module Type - Compact


RVXVHT080GE RVXVHT100GE RVXVHT120GE RVXVHT140GE RVXVHT160GE

Outdoor Units

Power supply Mode *1) Performance

Horse Power Capacity Cooling *2) Heating *3)

Horse Power Capacity Cooling *2) Heating *3)

Power

COP Fan Piping Connections

Refrigerant Sound Set Size

Nominal Input Cooling Heating Circuit Breaker (MCCB/ELB) Cooling Heating Type/Control Liquid Gas Discharge Gas (DVM PLUS III HR) Oil (Flare) Installation Max.Length Limitation Max.Height Type Factory Charging Sound Pressure *4) Net Weight DVM PLUS III DVM PLUS III HR Shipping Weight DVM PLUS III DVM PLUS III HR Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Cooling Heating

Power

COP Fan Piping Connections

Refrigerant Sound Set Size

Nominal Input Cooling Heating Circuit Breaker (MCCB/ELB) Cooling Heating Type/Control Liquid Gas Discharge Gas (DVM PLUS III HR) Oil (Flare) Installation Max.Length Limitation Max.Height Type Factory Charging Sound Pressure *4) Net Weight DVM PLUS III DVM PLUS III HR Shipping Weight DVM PLUS III DVM PLUS III HR Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Cooling Heating

Operating Temp. Range

Operating Temp. Range

2 3/380~415/50 HP/HR 32 89.6 305,800 100.8 344,000 29.60 30.00 100 3.03 3.36 Propeller/BLDC 19.05 31.75 28.58 6.35 200 50 (40) R410A 11x2 63 320x2 323x2 337x2 340x2 (1,200x1,703x765)x2 (1,268x1,868x832)x2 -5~43 -20~24

3/380~415/50 HP/HR 34 95.2 324,700 107.1 365,500 28.58 25.96 100 3.33 4.13 Propeller/BLDC 19.05 31.75 28.58 6.35 200 50 (40) R410A 7.5x3 64 240x3 242x3 253x3 255x3 (880x1,703x765)x3 (948x1,868x832)x3 -5~43 -20~24

Notes

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. - Specifications are subject to change without prior notice for product improvement.

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. - Specifications are subject to change without prior notice for product improvement.

2008 SAMSUNG DVM Air Conditioners

Outdoor Units

Outdoor Units - DVM PLUS III / HR

36

37

Specification |
Model Basic

DVM PLUS III / HR Module Type - Compact


36 HP 38 HP 40 HP Model Basic 3 2 1 3/380~415/50 HP/HR 38 106.4 363,000 119.7 408,500 31.80 29.20 125 3.35 4.10 Propeller/BLDC 19.05 38.10 31.75 6.35 200 50 (40) R410A 7.5x2+11x1 64 240x2+320x1 242x2+323x1 253x2+337x1 255x2+340x1 (880x1,703x765)x2+(1,200x1,703x765)x1 (948x1,868x832)x2+(1,268x1,868x832)x1 -5~43 -20~24 2 1 3/380~415/50 HP/HR 40 112.0 382,100 126.0 430,000 35.60 33.80 125 3.15 3.73 Propeller/BLDC 19.05 38.10 31.75 6.35 200 50 (40) R410A 7.5x2+11x1 64 240x2+320x1 242x2+323x1 253x2+337x1 255x3+340x1 (880x1,703x765)x2+(1,200x1,703x765)x1 (948x1,868x832)x2+(1,268x1,868x832)x1 -5~43 -20~24 RVXVHT080GE RVXVHT100GE RVXVHT120GE RVXVHT140GE RVXVHT160GE / / / / / RVXVRT080GE RVXVRT100GE RVXVRT120GE RVXVRT140GE RVXVRT160GE /V/Hz HP kW Btu/h kW Btu/h kW kW A ,mm ,mm ,mm ,mm m m kg dB(A) kg kg kg kg mm mm C C 42 HP 44 HP 46 HP / / / / / RVXVRT080GE RVXVRT100GE RVXVRT120GE RVXVRT140GE RVXVRT160GE /V/Hz HP kW Btu/h kW Btu/h kW kW A ,mm ,mm ,mm ,mm m m kg dB(A) kg kg kg kg mm mm C C

Module Type - Compact


RVXVHT080GE RVXVHT100GE RVXVHT120GE RVXVHT140GE RVXVHT160GE

Power supply Mode *1) Performance

Horse Power Capacity Cooling *2) Heating *3)

Power

COP Fan Piping Connections

Refrigerant Sound Set Size

Nominal Input Cooling Heating Circuit Breaker (MCCB/ELB) Cooling Heating Type/Control Liquid Gas Discharge Gas (DVM PLUS III HR) Oil (Flare) Installation Max.Length Limitation Max.Height Type Factory Charging Sound Pressure *4) Net Weight DVM PLUS III DVM PLUS III HR Shipping Weight DVM PLUS III DVM PLUS III HR Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Cooling Heating

Operating Temp. Range

3/380~415/50 HP/HR 36 100.8 343,800 113.4 387,000 31.20 28.20 100 3.23 4.02 Propeller/BLDC 19.05 38.10 31.75 6.35 200 50 (40) R410A 7.5x3 64 240x3 242x3 253x3 255x3 (880x1,703x765)x3 (948x1,868x832)x3 -5~43 -20~24

Power supply Mode *1) Performance

Horse Power Capacity Cooling *2) Heating *3)

Power

COP Fan Piping Connections

Refrigerant Sound Set Size

Nominal Input Cooling Heating Circuit Breaker (MCCB/ELB) Cooling Heating Type/Control Liquid Gas Discharge Gas (DVM PLUS III HR) Oil (Flare) Installation Max.Length Limitation Max.Height Type Factory Charging Sound Pressure *4) Net Weight DVM PLUS III DVM PLUS III HR Shipping Weight DVM PLUS III DVM PLUS III HR Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Cooling Heating

1 1 1 3/380~415/50 HP/HR 42 117.6 401,300 132.3 451,500 36.20 34.80 125 3.25 3.80 Propeller/BLDC 19.05 38.10 31.75 6.35 200 50 (40) R410A 7.5x1+11x2 64 240x1+320x2 242x1+323x2 253x1+337x2 255x1+340x2 (880x1,703x765)x1+(1,200x1703x765)x2 (948x1,868x832)x1+(1,268x1748x832)x2 -5~43 -20~24

2 1 3/380~415/50 HP/HR 44 123.2 420,500 138.6 473,000 36.80 35.80 125 3.35 3.87 Propeller/BLDC 19.05 38.10 31.75 6.35 200 50 (40) R410A 11x3 65 320x3 323x3 337x3 340x3 (1,200x1,703x765)x3 (1,268x1,868x832)x3 -5~43 -20~24

1 2 3/380~415/50 HP/HR 46 128.8 439,600 144.9 494,500 40.60 40.40 125 3.17 3.59 Propeller/BLDC 19.05 38.10 31.75 6.35 200 50 (40) R410A 11x3 65 320x3 323x3 337x3 340x3 (1,200x1,703x765)x3 (1,268x1,868x832)x3 -5~43 -20~24

Outdoor Units

Operating Temp. Range

Notes

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. - Specifications are subject to change without prior notice for product improvement.

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. - Specifications are subject to change without prior notice for product improvement.

2008 SAMSUNG DVM Air Conditioners

Outdoor Units

Outdoor Units - DVM PLUS III / HR

38

39

Specification |
Model Basic

DVM PLUS III / HR Module Type - Compact


48 HP 50 HP 52 HP Model Basic 3 1 3 3/380~415/50 HP/HR 48 134.4 458,700 151.2 516,000 44.40 45.00 125 3.03 3.36 Propeller/BLDC 19.05 38.10 31.75 6.35 200 50 (40) R410A 11x3 65 320x3 323x3 337x3 340x3 (1,200x1,703x765)x3 (1,268x1,868x832)x3 -5~43 -20~24 3/380~415/50 HP/HR 50 140.0 477,600 157.5 537,500 42.20 38.60 150 3.32 4.08 Propeller/BLDC 22.23 44.50 38.10 6.35 200 50 (40) R410A 7.5x3+11x1 66 240x3+320x1 242x3+323x1 253x3+337x1 255x3+340x1 (880x1,703x765)x3+(1,200x1,703x765)x1 (948x1,868x832)x3+(1,268x1,868x832)x1 -5~43 -20~24 3 1 3/380~415/50 HP/HR 52 145.6 496,700 163.8 559,000 46.00 43.20 150 3.17 3.79 Propeller/BLDC 22.23 44.50 38.10 6.35 200 50 (40) R410A 7.5x3+11x1 66 240x3+320x1 242x3+323x1 253x3+337x1 255x3+340x1 (880x1,703x765)x3+(1,200x1,703x765)x1 (948x1,868x832)x3+(1,268x1,868x832)x1 -5~43 -20~24 RVXVHT080GE RVXVHT100GE RVXVHT120GE RVXVHT140GE RVXVHT160GE / / / / / RVXVRT080GE RVXVRT100GE RVXVRT120GE RVXVRT140GE RVXVRT160GE /V/Hz HP kW Btu/h kW Btu/h kW kW A ,mm ,mm ,mm ,mm m m kg dB(A) kg kg kg kg mm mm C C 54 HP 1 1 2 3/380~415/50 HP/HR 54 151.2 515,900 170.1 580,500 47.78 46.56 150 3.16 3.65 Propeller/BLDC 22.23 44.50 38.10 6.35 200 50 (40) R410A 7.5x2+11x2 66 240x2+320x2 242x2+323x2 253x2+337x2 255x2+340x2 (880x1,703x765)x2+(1,200x1,703x765)x2 (948x1,868x832)x2+(1,268x1,868x832)x2 -5~43 -20~24 56 HP 1 1 2 3/380~415/50 HP/HR 56 156.8 535,100 176.4 602,000 48.38 47.56 150 3.24 3.71 Propeller/BLDC 22.23 44.50 38.10 6.35 200 50 (40) R410A 7.5x1+11x3 66 240x1+320x3 242x1+323x3 253x1+337x3 255x1+340x3 (880x1,703x765)x1+(1,200x1,703x765)x3 (948x1,868x832)x1+(1,268x1,868x832)x3 -5~43 -20~24 / / / / / RVXVRT080GE RVXVRT100GE RVXVRT120GE RVXVRT140GE RVXVRT160GE /V/Hz HP kW Btu/h kW Btu/h kW kW A ,mm ,mm ,mm ,mm m m kg dB(A) kg kg kg kg mm mm C C

Module Type - Compact


RVXVHT080GE RVXVHT100GE RVXVHT120GE RVXVHT140GE RVXVHT160GE

Outdoor Units

Power supply Mode *1) Performance

Horse Power Capacity Cooling *2) Heating *3)

Power supply Mode *1) Performance

Horse Power Capacity Cooling *2) Heating *3)

Power

COP Fan Piping Connections

Refrigerant Sound Set Size

Nominal Input Cooling Heating Circuit Breaker (MCCB/ELB) Cooling Heating Type/Control Liquid Gas Discharge Gas (DVM PLUS III HR) Oil (Flare) Installation Max.Length Limitation Max.Height Type Factory Charging Sound Pressure *4) Net Weight DVM PLUS III DVM PLUS III HR Shipping Weight DVM PLUS III DVM PLUS III HR Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Cooling Heating

Power

COP Fan Piping Connections

Refrigerant Sound Set Size

Nominal Input Cooling Heating Circuit Breaker (MCCB/ELB) Cooling Heating Type/Control Liquid Gas Discharge Gas (DVM PLUS III HR) Oil (Flare) Installation Max.Length Limitation Max.Height Type Factory Charging Sound Pressure *4) Net Weight DVM PLUS III DVM PLUS III HR Shipping Weight DVM PLUS III DVM PLUS III HR Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Cooling Heating

Operating Temp. Range

Operating Temp. Range

Notes

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. - Specifications are subject to change without prior notice for product improvement.

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. - Specifications are subject to change without prior notice for product improvement.

2008 SAMSUNG DVM Air Conditioners

Outdoor Units

Outdoor Units - DVM PLUS III / HR

40

41

Specification |
Model Basic

DVM PLUS III / HR Module Type - Compact


58 HP 60 HP Model Basic 1 1 3 3/380~415/50 HP/HR 58 162.4 554,200 182.7 623,500 52.18 52.16 150 3.11 3.50 Propeller/BLDC 22.23 44.50 38.10 6.35 200 50 (40) R410A 7.5x1+11x3 66 240x1+320x3 242x1+323x3 253x1+337x3 255x1+340x3 (880x1,703x765)x1+(1,200x1,703x765)x3 (948x1,868x832)x1+(1,268x1,868x832)x3 -5~43 -20~24 3 3/380~415/50 HP/HR 60 168.0 573,300 189.0 645,000 54.80 54.40 175 3.07 3.47 Propeller/BLDC 22.23 44.50 38.10 6.35 200 50 (40) R410A 7.5x1+11x3 67 240x1+320x3 242x1+323x3 253x1+337x3 255x1+340x3 (880x1,703x765)x1+(1,200x1,703x765)x3 (948x1,868x832)x1+(1,268x1,868x832)x3 -5~43 -20~24 RVXVHT080GE RVXVHT100GE RVXVHT120GE RVXVHT140GE RVXVHT160GE / / / / / RVXVRT080GE RVXVRT100GE RVXVRT120GE RVXVRT140GE RVXVRT160GE /V/Hz HP kW Btu/h kW Btu/h kW kW A ,mm ,mm ,mm ,mm m m kg dB(A) kg kg kg kg mm mm C C 62 HP 64 HP / / / / / RVXVRT080GE RVXVRT100GE RVXVRT120GE RVXVRT140GE RVXVRT160GE /V/Hz HP kW Btu/h kW Btu/h kW kW A ,mm ,mm ,mm ,mm m m kg dB(A) kg kg kg kg mm mm C C

Module Type - Compact


RVXVHT080GE RVXVHT100GE RVXVHT120GE RVXVHT140GE RVXVHT160GE

Power supply Mode *1) Performance

Horse Power Capacity Cooling *2) Heating *3)

Power supply Mode *1) Performance

Horse Power Capacity Cooling *2) Heating *3)

Power

COP Fan Piping Connections

Refrigerant Sound Set Size

Nominal Input Cooling Heating Circuit Breaker (MCCB/ELB) Cooling Heating Type/Control Liquid Gas Discharge Gas (DVM PLUS III HR) Oil (Flare) Installation Max.Length Limitation Max.Height Type Factory Charging Sound Pressure *4) Net Weight DVM PLUS III DVM PLUS III HR Shipping Weight DVM PLUS III DVM PLUS III HR Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Cooling Heating

Power

COP Fan Piping Connections

Refrigerant Sound Set Size

Nominal Input Cooling Heating Circuit Breaker (MCCB/ELB) Cooling Heating Type/Control Liquid Gas Discharge Gas (DVM PLUS III HR) Oil (Flare) Installation Max.Length Limitation Max.Height Type Factory Charging Sound Pressure *4) Net Weight DVM PLUS III DVM PLUS III HR Shipping Weight DVM PLUS III DVM PLUS III HR Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Cooling Heating

Operating Temp. Range

Operating Temp. Range

1 3 3/380~415/50 HP/HR 62 173.6 592,500 195.3 666,500 55.40 55.40 175 3.13 3.53 Propeller/BLDC 22.23 44.50 38.10 6.35 200 50 (40) R410A 11x4 67 320x4 323x4 337x4 340x4 (1,200x1,703x765)x4 (1,268x1,868x832)x4 -5~43 -20~24

Outdoor Units

4 3/380~415/50 HP/HR 64 179.2 611,600 201.6 688,000 59.20 60.00 175 3.03 3.36 Propeller/BLDC 22.23 44.50 38.10 6.35 200 50 (40) R410A 11x4 67 320x4 323x4 337x4 340x4 (1,200x1,703x765)x4 (1,268x1,868x832)x4 -5~43 -20~24

Notes

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. - Specifications are subject to change without prior notice for product improvement.

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. - Specifications are subject to change without prior notice for product improvement.

2008 SAMSUNG DVM Air Conditioners

Outdoor Units

Outdoor Units - Mini DVM

42

43

Mini DVM

Slim and Flexible

Mini DVM is a highly compact and reliable unit for luxurious residential buildings or light commercial applications with a Digital Scroll Compressor which ensures high energy efficiency.

Outdoor Units

High Energy Efficiency


Digital Scroll compressor offers very high cooling and heating COP.
COP

Compact Design
Mini DVM offers easy installation with its slim and compact design saving installation space. Dimension

4.05 4 3.33 3 3.04 3.87 3.05 3.73

Capacity Volume (m3) Foot print (m2) Height (mm) Weight (kg)

4Hp 0.39 0.35 1,128 124

5Hp 0.39 0.35 1,128 125

6Hp 0.39 0.35 1,128 125

Cooling Heating
4HP 5HP 6HP

Easy Maintenance
Mini DVM makes it possible to control compressor, PCB, EEV on front panel allowing simple and effortless maintenance. It is possible to react promptly to errors because they are displayed on LED of the outdoor units by error codes.

High Reliability
Mini DVM is highly reliable with adopted Digital Scroll Compressor which can be controlled easily. Because Digital Scroll Compressor needs just one control PCB, it achieves simple structure and high reliability.

Various Indoor Units


High energy-efficient system Compact outdoor unit Wide Compatibility
2008 SAMSUNG DVM Air Conditioners

Wide Compatibility
Mini DVM can be controlled by a control solution which is the same with that of DVM PLUS III and FJM

1, 220~240V, 50Hz (4/5HP) 3, 380~415V, 50Hz (5/6HP)

Mini DVM can be combined up to 9 stylish indoor units blending with any interior design.

Outdoor Units

Outdoor Units - Mini DVM

44

45

Specification |
Model Power Supply Mode *1) Performance

Mini DVM
RVXMHF040EA RVXMHF050EA 1/220~240/50 HP 5 14.0 47,700 16.0 54,500 22.4 20.1 4.60 4.13 30 3.04 3.87 Digital Scroll 62.98 3MAF POE 1,893 Propeller 200x2 105 9.52 15.88 100 30 R410A 5.5 55/57 125 133 932x1,128x375 1,091x1,286x472 -5~43 -20~24 RVXMHF050GA 3/380~415/50 HP 5 14.0 47,700 16.0 45,500 8.5 7.8 4.61 4.13 20 3.04 3.87 Digital Scroll 67.13 3MAF POE 1,893 Propeller 200x2 105 9.52 15.88 100 30 R410A 5.5 55/57 125 133 932x1,128x375 1,091x1,286x472 -5~43 -20~24 RVXMHF060GA 3/380~415/50 HP 6 16.0 54,500 18.0 61,400 11.0 9.9 5.24 4.82 20 3.05 3.73 Digital Scroll 77.20 3MAF POE 1,774 Propeller 220x2 105 9.52 15.88 100 30 R410A 5.5 57/60 125 133 932x1,128x375 1,091x1,286x472 -5~43 -15~24 Model Power Supply Mode *1) Performance /V/Hz Horse Power HP Capacity Cooling *2) kW Btu/h Heating *3) kW Btu/h Nominal Running Cooling A Current Heating A Nominal Input Cooling kW Heating kW Circuit Breaker (MCCB/ELB) A Cooling Heating Type Piston Displacement cc/Rev Output kW Lubricant Type Charging cc Type Output W Airflow Rate m3/min Liquid (Flare) ,mm Gas (Flare) ,mm Installation Max. Length m Limitation Max. Height m Type Factory Charging kg Sound Pressure(Cooling/Heating) *4) dB(A) Net Weight kg Shipping Weight kg Net Dimensions (WxHxD) mm Shipping Dimensions (WxHxD) mm Cooling C Heating C RVMMH120EZ 1/220~240/50 HP 4 12.0 40,900 14.0 47,700 18.0 18.0 3.56 3.58 3.37 3.91 Digital Scroll SONTEX 200LT Propeller 95 9.52 19.05 70 30 R22 6.5 55/56 124 132 932x1,128x375 1,091x1,286x472 -5~43 -15~24 RVMMH120GZ RVMMH140EZ RVMMH140GZ RVMMH160GZ 3/380~415/50 1/220~240/50 HP HP 4 5 12.0 14.0 40,900 47,700 14.0 16.0 47,700 54,500 6.5 22.5 6.4 21.5 3.80 4.65 3.58 4.50 3.16 3.01 3.91 3.56 Digital Scroll Digital Scroll 82.59 93.03 SONTEX 200LT SONTEX 200LT 1,890 1,890 Propeller Propeller 95 95 9.52 9.52 19.05 19.05 70 70 30 30 R22 R22 6.5 6.5 55/59 55/57 124 125 132 133 932x1,128x375 932x1,128x375 1,091x1,286x472 1,091x1,286x472 -5~43 -5~43 -15~24 -15~24 3/380~415/50 HP 5 14.0 47,700 16.0 54,550 8.5 8.0 4.90 4.30 2.86 3.72 Digital Scroll 98.06 4.2 SONTEX 200LT 1,890 Propeller 95 9.52 19.05 70 30 R22 6.5 55/57 125 133 932x1,128x375 1,091x1,286x472 -5~43 -15~24 3/380~415/50 HP 6 16.0 54,500 18.0 61,400 10.2 9.9 5.55 5.20 2.89 3.46 Digital Scroll 107.80 SONTEX 200LT 1,890 Propeller 95 9.52 19.05 70 30 R22 6.5 57/60 125 133 932x1,128x375 1,091x1,286x472 -5~43 -15~24

Power

COP Compressor

Fan

Piping Connections

Refrigerant Sound Set Size

Operating Temp. Range


Notes

/V/Hz Horse Power HP Capacity Cooling *2) kW Btu/h Heating *3) kW Btu/h Nominal Running Cooling A Current Heating A Nominal Input Cooling kW Heating kW Circuit Breaker (MCCB/ELB) A Cooling Heating Type Piston Displacement cc/Rev Output kW Lubricant Type Charging cc Type Output W Airflow Rate m3/min Liquid (Flare) ,mm Gas (Flare) ,mm Installation Max. Length m Limitation Max. Height m Type Factory Charging kg Sound Pressure(Cooling/Heating) *4) dB(A) Net Weight kg Shipping Weight kg Net Dimensions (WxHxD) mm Shipping Dimensions (WxHxD) mm Cooling C Heating C

1/220~240/50 HP 4 12.5 42,600 14.5 49,400 19.0 18.0 3.75 3.58 30 3.33 4.05 Digital Scroll 58.10 3MAF POE 1,893 Propeller 200x2 105 9.52 15.88 100 30 R410A 5.5 55/56 124 132 932x1,128x375 1,091x1,286x472 -5~43 -20~24

Outdoor Units

Power

COP Compressor

Fan

Piping Connections

Refrigerant Sound Set Size

Operating Temp. Range


Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. - Specifications are subject to change without prior notice for product improvement.

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. - Specifications are subject to change without prior notice for product improvement.

2008 SAMSUNG DVM Air Conditioners

Outdoor Units

Outdoor Units - Free Joint Multi

46

47

Free Joint Multi


Free Joint Multi supports various combinations of indoor and outdoor units, providing variety of choices and flexible installation. Therefore, Free Joint Multi is the best solution for residential buildings seeking flexible, efficient and reliable air conditioning system.

High Energy Efficiency

Outdoor Units

TBR Sine-Wave Compressor


New FJM models have applied the twin BLDC compressor with highly stable moving parts which reduced torque variation by 70% compared to the conventional single BLDC compressor.

Conventional

New

High Performance
Wide Operation Range of Outdoor Temperature BLDC(Twin Rotary) Compressor
BLDC Compressor is applied on all FJM outdoor models.

Sine Wave Controller


All the FJM models have adopted this newly developed Sine Wave Controller. No nipple in the current wave makes soft acoustic quality and reduces noise.
Current Wave Torque Ripple Current Wave Torque Ripple Current Wave Torque Ripple Current Wave Torque Ripple

Highly Efficient BLDC Motor - Creative motor core design - High density neodymium magnet - Concentrated type stator Extremely Low Vibration - Twin eccentric cams - 2 balance weights Highly Stable Moving Parts - Optimal material matching rollers and vanes - Highly robust bearings - Coated vane - Coated shaft

Conventional Square Wave Controller

New Sine Wave Controller

Felt Structure
New felt has been selected to reduce the noise coming out of the compressor. Double layered felt structure absorbs noise by two times and felt is also covering top of the compressor to reduce the noise even more.

2008 SAMSUNG DVM Air Conditioners

Outdoor Units

Outdoor Units - Free Joint Multi

48

49

Line up
Available Outdoor Units
MH040FXEA2B
4.0kW 2 Unit

Specification |
MH050FXEA2B
5.0kW 2 Unit

Outdoor Units

MH060FXEA3B
6.0kW 3 Unit

MH070FXEA4B
7.0kW 4 Unit

MH080FXE4B
8.0kW 4 Unit

Model Power Supply Mode *1) Max number of connectable indoor units Performance Horse Power Capacity Cooling *2) Heating *3) Sound Power Sound Pressure (Cooling/Heating) *4) Running Cooling Current Heating Nominal Input Cooling Heating Circuit Breaker(MCCB/ELB) Type Piston Displacement Output Lubricant Type Charging Type Factory Charging Type Output Airflow Rate Net Weight Shipping Weight Net Dimensions(WxHxD) Shipping Dimensions(WxDxH) Liquid(Flare) Gas(Flare) Installation Max. Length Limitation Max. Height Cooling Heating /V/Hz HP kW Btu/h kW Btu/h dB(A) A A W W A cc/Rev kW cc kg W m3/min kg kg mm mm ,mm ,mm m m C C

MH040FXEA2B MH050FXEA2B MH060FXEA3B MH070FXEA4B*5) MH080FXEA4B*5) 1/220~240/50 1/220~240/50 1/220~240/50 1/220~240/50 1/220~240/50 HP HP HP HP HP 2 4 4 2 3 1.5 2.5 3.0 1.8 2.0 3.9 7.0 8.0 5.0 5.9 13,307 23,884 27,296 17,060 20,131 4.4 8.6 9.3 5.7 6.3 15,013 29,343 31,732 19,448 21,496 47/48 50/51 51/51 48/50 49/50 5.2 8.7 10.5 6.1 7.3 5.1 9.2 10.1 6.4 6.4 1,140 1,900 2,300 1,330 1,600 1,120 2,000 2,200 1,400 1,400 9 16.6 16.6 13.5 14.5 TWIN BLDC INV. TWIN BLDC INV. TWIN BLDC INV. TWIN BLDC INV. TWIN BLDC INV. 19.52 25.18 25.18 19.52 19.52 5.86 7.77 7.77 5.86 5.86 POE POE POE POE POE 700 700 700 700 700 R410A R410A R410A R410A R410A 1.3 2.8 2.8 2 2.2 Propeller Propeller Propeller Propeller Propeller 25 130 130 40 130 25.4 44.8 45.4 32.9 41 41 65 65 53 59 44 70 70 57 63 790X548X285 880X798X310 880X798X310 880X638X310 880X798X310 926X630X382 1,023X695X413 1,023X889X413 1,023X889X413 1,023X889X413 6.35X2 6.35X2 6.35X3 6.35X4 6.35X4 9.52X2 9.52X1+12.70X1 9.52X2+12.70X1 9.52X2+12.70X2 9.52X2+12.70X2 30 30 45 70 70 15 15 15 15 15 -5~43 -5~43 -5~43 -5~43 -5~43 -15~24 -15~24 -15~24 -15~24 -15~24

Outdoor Units

Combination Table
Indoor Unit Model
MH026FBEA MH035FBEA MH052FBEA MH020FVEA MH026FVEA MH035FVEA MH052FVEA MH020FNEA MH026FNEA MH035FNEA MH052FNEA MH026FJEA MH035FJEA MH026FKEA MH035FKEA MH030FMEA MH035FMEA MH052FMEA MH026FEEA MH035FEEA MH052FUEA MH040FXEA2B MH050FXEA2B

Compressor

Outdoor Unit
MH060FXEA3B MH070FXEA4B MH080FXEA4B

Refrigerant Fan

Set Size

Piping Connections

Operating Temp. Range


Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications are subject to change without prior notice for product improvement.

2008 SAMSUNG DVM Air Conditioners

Outdoor Units

Outdoor Units - Free Joint Multi

50
MB

51
Neo Forte

Specification |
Model Power Supply Mode *1) Performance Cooling *2) Heating *3) Sound Power

Indoor Units
MH026FBEA /V/Hz kW Btu/h kW Btu/h dB(A) m3/min mmAq A W ,mm ,mm ,mm kg kg mm mm 1/220~240/50 HP 2.6 8,871 2.9 9,895 31/20 *5) Cross Flow Fan 8.14/8.23 0.18/0.18 30/30 6.35 9.52 ID 18 10.2 11.5 900X304X185 963X349X247 MH035FBEA 1/220~240/50 HP 3.5 11,942 3.8 12,966 35/21 *5) Cross Flow Fan 9.16/9.46 0.19/0.19 35/35 6.35 9.52 ID 18 10.2 11.5 900X304X185 963X349X247 -

MH052FBEA 1/220~240/50 HP 5.2 17,742 5.6 19,107 40/30 *5) Cross Flow Fan 14.98/14.49 0.3/0.3 50/50 6.35 12.70 ID 18 13.0 16.0 1,100X307X225 1,157X381X292 Power Supply Mode *1) Performance Cooling *2) Heating *3) Sound Power

Model /V/Hz kW Btu/h kW Btu/h dB(A) m3/min mmAq A W ,mm ,mm ,mm kg kg mm mm -

MH020FNEA 1/220~240/50 HP 2 6,824 2.2 7,506 32/23 *5) Cross Flow Fan 7.73/8 0.18/0.18 30/30 6.35 9.52 ID 18 7.8 9.4 825X285X189 900X349X252 -

MH026FNEA 1/220~240/50 HP 2.6 8,871 2.9 9,895 32/23 *5) Cross Flow Fan 8.31/8.56 0.18/0.18 30/30 6.35 9.52 ID 18 7.8 9.4 825X285X189 900X349X252 -

MH035FNEA 1/220~240/50 HP 3.5 11,942 3.8 12,966 36/23 *5) Cross Flow Fan 9.54/9.93 0.19/0.19 35/35 6.35 9.52 ID 18 7.8 9.4 825X285X189 900X349X252 -

MH052FNEA 1/220~240/50 HP 5.2 17,742 5.6 19,107 40/30 *5) Cross Flow Fan 13.21/14.22 0.3/0.3 50/50 6.35 12.70 ID 18 13.0 16.0 1,099X315X217 1,137X377X299 -

Outdoor Units

Piping

Set Size

Accessories

Sound Pressure (High/Low) *4) Fan Type Airflow Rate(Cool/Heat) External Static Pressure(Standard/High) Running Current Cooling/Heating Power Input Cooling/Heating Connecting Pipe Liquid(Flare) Gas(Flare) Drain Net Weight Shipping Weight Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Panel Filter Drain Pump

Piping

Set Size

Accessories

Sound Pressure (High/Low) *4) Fan Type Airflow Rate(Cool/Heat) External Static Pressure(Standard/High) Running Current Cooling/Heating Power Input Cooling/Heating Connecting Pipe Liquid(Flare) Gas(Flare) Drain Net Weight Shipping Weight Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Panel Filter Drain Pump

Vivace

Console

1Way Cassette

Model Power Supply Mode *1) Performance Cooling *2) Heating *3) Sound Power Sound Pressure (High/Low) *4) Fan Type Airflow Rate(Cool/Heat) External Static Pressure(Standard/High) Running Current Cooling/Heating Power Input Cooling/Heating Connecting Pipe Liquid(Flare) Gas(Flare) Drain Net Weight Shipping Weight Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Panel Filter Drain Pump /V/Hz kW Btu/h kW Btu/h dB(A) m3/min mmAq A W ,mm ,mm ,mm kg kg mm mm -

MH020FVEA 1/220~240/50 HP 2 6,824 2.2 7,506 31/21 *5) Cross Flow Fan 7.5/8.1 0.18/0.18 30/30 6.35 9.52 ID 18 8.5 11.5 825X285X189 900X349X252 -

MH026FVEA 1/220~240/50 HP 2.6 8,871 2.9 9,895 31/21 *5) Cross Flow Fan 8.5/8.3 0.18/0.18 30/30 6.35 9.52 ID 18 8.5 11.5 825X285X189 900X349X252 -

MH035FVEA 1/220~240/50 HP 3.5 11,942 3.8 12,966 35/21 *5) Cross Flow Fan 10/10.4 0.19/0.19 35/35 6.35 9.52 ID 18 8.5 11.5 825X285X189 900X349X252 -

MH052FVEA 1/220~240/50 HP 5.2 17,742 5.6 19,107 40/30 *5) Cross Flow Fan 14.8/14.8 0.3/0.3 50/50 6.35 12.70 ID 18 12.0 15.0 1,065X298X214 1,137X377X299 Power Supply Mode *1) Performance Cooling *2) Heating *3) Sound Power

Model /V/Hz kW Btu/h kW Btu/h dB(A) m3/min mmAq A W ,mm ,mm ,mm kg kg mm mm -

MH026FJEA 1/220~240/50 HP 2.6 8,871 2.9 9,895 Turbo Fan 6.35 9.52 14.5 18.5 720x620x199 810x710x295 -

MH035FJEA 1/220~240/50 HP 3.5 11,942 3.8 12,966 Turbo Fan 6.35 9.52 14.5 18.5 720x620x199 810x710x295 -

MH026FKEA 1/220~240/50 HP 2.6 8,800 2.9 9,800 36/33 Cross Flow Fan 7.0/7.5 0.20/0.20 40/40 6.35 9.52 VP:20 (OD:26, ID:20) 15.0 18.0 970x180x390 1,168x302x467 Option (P1SMA) Built-in Built-in

MH035FKEA 1/220~240/50 HP 3.5 11,900 3.8 12,900 38/35 Cross Flow Fan 7.5/8.0 0.23/0.23 45/45 6.35 9.52 VP:20 (OD:26, ID:20) 15.0 18.0 970x180x390 1,168x302x467 Option (P1SMA) Built-in Built-in

Piping

Piping

Set Size

Set Size

Accessories

Accessories

Sound Pressure (High/Low) *4) Fan Type Airflow Rate(Cool/Heat) External Static Pressure(Standard/High) Running Current Cooling/Heating Power Input Cooling/Heating Connecting Pipe Liquid(Flare) Gas(Flare) Drain Net Weight Shipping Weight Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Panel Filter Drain Pump

Notes

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications are subject to change without prior notice for product improvement.
2008 SAMSUNG DVM Air Conditioners

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications are subject to change without prior notice for product improvement.
Outdoor Units

Outdoor Units - Free Joint Multi

52
Mini 4Way Cassette

53

Specification |
Model Power Supply Mode *1) Performance Cooling *2) Heating *3) Sound power

Indoor Units
MH030FMEA /V/Hz kW Btu/h kW Btu/h dB(A) m3/min mmAq A W ,mm ,mm ,mm kg kg mm mm 1/220~240/50 HP 3.0 10,200 3.4 11,600 40/37 Turbo Fan 10.8/11.7 0.37/0.37 85/85 6.35 9.52 VP:25 (OD:32, ID:25) 17.0 20.0 575x242x575 660x310x635 PMSMA Built-in Built-in MH035FMEA 1/220~240/50 HP 3.5 11,900 3.8 12,900 40/37 Turbo Fan 10.8/11.7 0.37/0.37 85/85 6.35 9.52 VP:25 (OD:32, ID:25) 17.0 20.0 575x242x575 660x310x635 PMSMA Built-in Built-in

Specification |
Model

Pack Multi Split (Forte Type)


Outdoor unit Indoor unit MH18VF1X MH18VF1-09 MH18VF1-09
kW kW kW EER COP EER COP EER COP l/h m3/min m3/min dB(A) dB(A) dB(A) /V/Hz W W W A A A mm mm mm kg kg kg kg kg kg W/O Pipe W/Pipe ,mm ,mm ,mm ,mm m m m kg g/m 2.6/2.9 2.6/2.9 3.9/4.4 3.47 3.44 3.47 3.44 3.36 3.79 1.6 8.3 8.3 43 43 51/52 1/220-240/50 750/900 750/900 1,160/1,160 3.4/4.1 3.4/4.1 5.3/5.3 825x285x189 825x285x189 548x790x285 8.4 8.4 41 10.6 10.6 44 153 6.35 9.52 6.35 9.52 7.5 30 7.5 1.3 10 q q q

MH052FMEA 1/220~240/50 HP 5.2 17,700 5.6 19,100 44/40 Turbo Fan 12.1/13.6 0.52/0.52 120/120 6.35 12.70 VP:25 (OD:32, ID:25) 17.0 20.0 575x242x575 660x310x635 PMSMA Built-in Built-in

MH19VF1X MH19VF1-07 MH19VF1-12


2.1/2.4 3.5/3.8 3.9/4.4 3.89 3.00 3.02 3.28 3.36 3.79 1.6 7.73 9.5 43 43 51/52 1/220-240/50 540/800 1,160/1,160 1,160/1,160 2.5/3.7 5.3/5.3 5.3/5.3 825x285x189 825x285x189 548x790x285 8.4 8.4 41 10.6 10.6 44 153 6.35 9.52 6.35 9.52 7.5 30 7.5 1.3 10 q q q

Capacity(Cooling/Heating)

Energy Efficiency

1Unit(A) 1Unit(B or C) 2Unit[A+(B or C)] 1Unit(A) 1Unit(B or C) 2Unit[A+(B or C)]

Outdoor Units

Piping

Set Size

Accessories

Sound Pressure (High/Low) *4) Fan Type Airflow Rate(Cool/Heat) External Static Pressure(Standard/High) Running Current Cooling/Heating Power Input Cooling/Heating Connecting Pipe Liquid(Flare) Gas(Flare) Drain Net Weight Shipping Weight Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Panel Filter Drain Pump

Moisture removal Airflow Rate(Max.) Sound Pressure(Max.)

1Unit(A) 1Unit(B or C) Indoor (A-Unit) Indoor (B-Unit or C-Unit) Outdoor Unit

Electrical Data Power Supply Power Input (Cooling/Heating)

Slim Duct

MSP Duct

Model Power Supply Mode *1) Performance Cooling *2) Heating *3) Sound power Sound Pressure (High/Low) *4) Fan Type Airflow Rate(Cool/Heat) External Static Pressure(Standard/High) Running Current Cooling/Heating Power Input Cooling/Heating Connecting Pipe Liquid(Flare) Gas(Flare) Drain Net Weight Shipping Weight Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Panel Filter Drain Pump /V/Hz kW Btu/h kW Btu/h dB(A) m3/min mmAq A W ,mm ,mm ,mm kg kg mm mm -

MH026FEEA 1/220~240/50 HP 2.6 8,800 2.9 9,800 31/26 Sirocco Fan 8.6/9.0 2/4 0.4/0.4 80/80 6.35 9.52 VP:25 (OD:32, ID:25) 26.0 31.0 900x199x600 1,133x333x722 Built-in MDP-E075SEE

MH035FEEA 1/220~240/50 HP 3.5 11,900 3.8 12,900 32/27 Sirocco Fan 9.8/10.3 2/4 0.4/0.4 80/80 6.35 0.92 VP:25 (OD:32, ID:25) 26.0 31.0 900x199x600 1,133x333x722 Built-in MDP-E075SEE

MH052FUEA 1/220~240/50 HP 5.2 17,742 5.6 19,107 Sirocco Fan 6/10 6.35 12.70 29.5 34.5 900x242x480 1,146x363x584 MSP-M075SGU3

1Unit(A) 1Unit(B or C) 2Unit[A+(B or C)] 1Unit(A) Running Current 1Unit(B or C) (Cooling/Heating) 2Unit[A+(B or C)] Dimensions and Loading Qty Indoor (A-Unit) Net Dimensions Indoor (B-Unit or C-Unit) (WxHxD) Outdoor Unit Indoor (A-Unit) Net Weight Indoor (B-Unit or C-Unit) Outdoor Unit Indoor (A-Unit) Shipping Weight Indoor (B-Unit or C-Unit) Outdoor Unit Loading Qty(40ft) Technical Information SVC Valve

Piping Length Piping Height Quantity of Refrigerant Additional Refrigerant Features Good Sleep II Silver Coated Health System Pure and Clean Air

Liquid(A) Gas(A) Liquid(B or C) Gas(B or C) Standard Max Max

Piping

Operating Mode

Set Size

Accessories

Convenience

Notes

*1) Mode - HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on - Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on - Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications are subject to change without prior notice for product improvement.
2008 SAMSUNG DVM Air Conditioners

Etc. Operating Temp. Range

Silver Coated Filter Silver Coated Evaporator DNA Filter Pure Filter(HAF Filter) Catechin Filter Deodorizing Filter Digital i Plus Dehumidification Turbo Mode Timer Energy Saving Mode Auto Restart Auto Changeover Auto Wind Airflow Control Steps(Cool/Fan) Air Direction Control(Up/Down) Air Direction Control(Left/Right) Auto Grille Remote Controller Auto Clean(Self cleaning) Compressor Type Cooling Heating

q q q q q q q 4/3 AUTO MANUAL q Rotary(BLDC) -5~43 -15~24

q q q q q q q 4/3 AUTO MANUAL q Rotary(BLDC) -5~43 -15~24

C C

Outdoor Units

Outdoor Units - Free Joint Multi

54

55

Capacity Combination
MH040FXEA2B
Number of Unit Indoor Unit Combination A
2000 2600 3500 2000 2000 2000 2600 2600

Cooling
Cooling Capacity(W) Total
2000 2600 3500 4000 4600 5500 5200 6100

MH060FXEA3B
Number of Unit Indoor Unit Combination A
2000

Cooling
Cooling Capacity(W) Total
2000 2600 3500 5200 4000 4600 5500 7200 5200 6100 7800 7000 8700 6000 6600 7500 7200 8100 9000 7800 8700

Capacity

Power Consumption

Current EG
A A B A A A A A

Capacity

Power Consumption

Current EG
A A A

B
2000 2600 3500 2600 3500

C
-

D
-

%
51% 67% 90% 103% 118% 141% 133% 156%

A
2100 2600 3500 1950 1696 1418 1950 1662

B
1950 2204 2482 1950 2238

C
-

D
-

Total
2100 2600 3500 3900 3900 3900 3900 3900

Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. COP W W Ml W W W A A A
1280 1280 1300 1350 1500 1500 1500 1500 2100 2600 3500 3900 3900 3900 3900 3900 2520 3120 4200 4200 4200 4200 4200 4200 400 400 400 420 420 440 440 440 540 750 1160 1160 1140 1160 1160 1140 630 880 1240 1250 1250 1250 1250 1250 2.2 2.2 2.2 2.3 2.3 2.4 2.4 2.4 2.5 3.4 5.3 5.3 5.2 5.3 5.3 5.2 2.9 4 5.7 5.7 5.7 5.7 5.7 5.7 3.89 3.47 3.02 3.36 3.42 3.36 3.36 3.42

B
2000 2600 3500 5200 2600 3500 5200 3500 5200 2000 2000 2000 2600 2600 3500 2600 2600

C
2000 2600 3500 2600 3500 3500 2600 3500

D
-

%
34% 44% 59% 88% 68% 78% 93% 122% 88% 103% 132% 119% 147% 102% 112% 127% 122% 137% 153% 132% 147%

A
2400 2600 3500 5200 2000 2000 1909 1528 2600 2259 1967 2725 2374 1760 1636 1573 1528 1457 1311 1967 1763

B
2000 2600 3341 3972 2600 3041 3933 2725 3526 1760 1636 1573 1986 1894 2294 1967 1763

C
1760 2127 2753 1986 2549 2294 1967 2374

D
-

Total
2400 2600 3500 5200 4000 4600 5250 5500 5200 5300 5900 5450 5900 5280 5400 5900 5500 5900 5900 5900 5900

Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. COP W W Ml W W W A A A
1280 1280 1280 1300 1300 1300 1300 1380 1300 1300 1380 1300 1380 1500 1500 1500 1500 1500 1500 1500 1500 2400 2600 3500 5200 4000 4600 5250 5500 5200 5300 5900 5450 5900 5280 5400 5900 5500 5900 5900 5900 5900 2880 3120 4200 5800 4800 5520 6290 6600 5800 6400 6800 6560 6800 6380 6490 6800 6600 6800 6800 6800 6800 400 400 400 400 420 420 430 430 420 430 430 430 440 430 430 440 430 440 440 440 440 730 790 1070 1620 1240 1410 1550 1580 1620 1550 1610 1570 1620 1550 1560 1610 1580 1610 1610 1600 1600 930 1010 1370 1900 1480 1680 1820 1850 1800 1840 1880 1850 1880 1840 1850 1880 1850 1880 1880 1880 1880 2.2 2.2 2.2 2.2 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.4 2.3 2.3 2.4 2.3 2.4 2.4 2.4 2.4 3.3 3.6 4.9 7.4 5.7 6.5 7.1 7.2 7.4 7.1 7.4 7.2 7.4 7.1 7.1 7.4 7.2 7.4 7.4 7.3 7.3 4.3 4.6 6.3 8.7 6.8 7.7 8.3 8.5 8.2 8.4 8.6 8.5 8.6 8.4 8.5 8.6 8.5 8.6 8.6 8.6 8.6 3.29 3.29 3.27 3.21 3.23 3.26 3.39 3.48 3.21 3.42 3.66 3.47 3.64 3.41 3.46 3.66 3.48 3.66 3.66 3.69 3.69

1 Unit

1 Unit

2600 3500 5200 2000 2000 2000

Outdoor Units

A A A A A A A A A A A A A A A A A A

2 Unit

Multi Split (Wall Mounted Type)


2 Unit
2000 2600 3500 2600 141% 133% 5500 5200 1418 1950 2482 1950 3900 3900 1500 1500 3900 3900 4200 4200 440 440 1160 1160 1250 1250 2.4 2.4 5.3 5.3 5.7 5.7 3.36 3.36 A A

2000

2 Unit

2600 2600

Heating
Number of Unit Indoor Unit Combination A
2200 2900 3800 2200 2200 2200 2900 2900

2600 3500

Heating Capacity(W) Total


2200 2900 3800 4400 5100 6000 5800 6700

Capacity

Power Consumption

Current EG
D B C A A A A A

B
2200 2900 3800 2900 3800

C
-

D
-

%
50% 66% 86% 100% 116% 136% 132% 152%

A
2400 3100 3800 2200 1898 1613 2200 1904

B
2200 2502 2787 2200 2496

C
-

D
-

Total
2400 3100 3800 4400 4400 4400 4400 4400

Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. COP W W Ml W W W A A A
1300 1300 1300 1500 1500 1500 1500 1500 2400 3100 3800 4400 4400 4400 4400 4400 2990 3450 4370 4700 4700 4700 4700 4700 280 280 280 300 300 300 300 300 800 900 1160 1160 1160 1160 1160 1120 910 1080 1420 1390 1420 1490 1490 1490 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 3.7 4.1 5.3 5.3 5.3 5.3 5.3 5.1 4.2 4.9 6.5 6.4 6.5 6.8 6.8 6.8 3.00 3.44 3.28 3.79 3.79 3.79 3.79 3.93

3500 2000 2000 2000

1 Unit

3 Unit

2000 2000 2000 2600 2600

2 Unit

Multi Split (Wall Mounted Type)


2 Unit
2200 2900 3800 2900 136% 132% 6000 5800 1613 2200 2787 2200 4400 4400 1500 1500 4400 4400 4700 4700 300 300 1160 1160 1490 1490 1.6 1.6 5.3 5.3 6.8 6.8 3.79 3.79 A A

Heating
Number of Unit Indoor Unit Combination A
2200

Heating Capacity(W) Total


2200 2900 3800 5600 4400 5100 6000 7800 5800 6700 8500 7600 9400 6600 7300 8200 8000 8900 9800 8700 9600

Capacity

Power Consumption

Current EG
D D D D A B B A B B A B A A A A A A A A A

MH050FXEA2B
Number of Unit Indoor Unit Combination A
2000 2600 3500 5200 2000 2000 2000 2000 2600 2600 2600 3500

Cooling
Cooling Capacity(W) Total
2000 2600 3500 5200 4000 4600 5500 7200 5200 6100 7800 7000

B
2200 2900 3800 5600 2900 3800 5600 3800 5600 2200 2200 2200 2900 2900 3800 2900 2900

C
2200 2900 3800 2900 3800 3800 2900 3800

D
-

%
35% 46% 60% 89% 70% 81% 95% 124% 92% 106% 135% 121% 149% 105% 116% 130% 127% 141% 156% 138% 152%

A
2500 2900 3800 5600 2200 2200 2053 1692 2900 2510 2149 2950 2547 1933 1778 1690 1650 1557 1414 2100 1903

B
2200 2900 3547 4308 2900 3290 4151 2950 3753 1933 1778 1690 2175 2053 2443 2100 1903

C
1933 2344 2920 2175 2690 2443 2100 2494

D
-

Total
2500 2900 3800 5600 4400 5100 5600 6000 5800 5800 6300 5900 6300 5800 5900 6300 6000 6300 6300 6300 6300

Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. COP W W A W Ml W W A A
1300 1300 1300 1350 1400 1400 1500 1500 1400 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 2500 2900 3800 5600 4400 5100 5600 6000 5800 5800 6300 5900 6300 5800 5900 6300 6000 6300 6300 6300 6300 2990 3340 4370 6300 5060 5870 6440 6900 6300 6770 7300 6880 7300 6760 6840 7300 6920 7300 7300 7300 7300 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 880 1030 1350 1820 1220 1490 1640 1660 1700 1700 1740 1730 1740 1590 1610 1660 1590 1630 1560 1650 1400 1110 1270 1660 1920 1510 1830 1860 1860 1910 1900 1830 1860 1830 1840 1840 1830 1840 1830 1830 1830 1830 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 4 4.7 6.2 8.3 5.6 6.8 7.5 7.6 7.8 7.8 8 7.9 8 7.3 7.4 7.6 7.3 7.5 7.1 7.6 6.4 5.1 5.8 7.6 8.8 6.9 8.4 8.5 8.5 8.7 8.7 8.4 8.5 8.4 8.4 8.4 8.4 8.4 8.4 8.4 8.4 8.4 2.84 2.82 2.81 3.08 3.61 3.42 3.41 3.61 3.41 3.41 3.62 3.41 3.62 3.65 3.66 3.80 3.77 3.87 4.04 3.82 4.50

Capacity

Power Consumption

Current EG 1 Unit
A A A B A A A A A A A A

B
2000 2600 3500 5200 2600 3500 5200 3500

C
-

D
-

%
40% 52% 70% 104% 80% 92% 110% 144% 104% 122% 156% 140%

A
2400 2600 3500 5000 2000 2000 1818 1389 2500 2131 1667 2500

B
2000 2600 3182 3611 2500 2869 3333 2500

C
-

D
-

Total
2400 2600 3500 5000 4000 4600 5000 5000 5000 5000 5000 5000

Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. COP W W A W Ml W W A A
1280 1280 1280 1300 1350 1350 1350 1500 1500 1500 1500 1500 2400 2600 3500 5000 4000 4600 5000 5000 5000 5000 5000 5000 2880 3120 4200 5200 4800 5200 5400 5400 5400 5400 5400 5400 400 400 400 400 420 420 420 440 440 440 440 440 730 800 1090 1660 1245 1430 1490 1380 1500 1500 1330 1500 880 960 1310 1740 1490 1720 1780 1800 1780 1780 1800 1780 1.9 1.9 1.9 1.9 2 2 2 2.1 2.1 2.1 2.1 2.1 3.3 3.7 5 7.6 5.7 6.5 6.8 6.3 6.9 6.9 6.1 6.9 4 4.4 6 8 6.8 7.9 8.1 8.2 8.1 8.1 8.2 8.1 3.29 3.25 3.21 3.01 3.21 3.22 3.36 3.62 3.33 3.33 3.76 3.33

2900 3800 5600 2200 2200 2200 2200

1 Unit

2 Unit

2 Unit

2900 2900 2900 3800 3800 2200 2200 2200

Heating
Number of Unit Indoor Unit Combination A
2200 2900 3800 5600 2200 2200 2200 2200 2900 2900 2900 3800

Heating Capacity(W) Total


2200 2900 3800 5600 4400 5100 6000 7800 5800 6700 8500 7600

Capacity

Power Consumption

Current EG
D D D D A A A A A A A A

B
2200 2900 3800 5600 2900 3800 5600 3800

C
-

D
-

%
39% 51% 67% 98% 77% 89% 105% 137% 102% 118% 149% 133%

A
2500 2900 3800 5400 2200 2200 2090 1608 2850 2467 1945 2850

B
2200 2900 3610 4092 2850 3233 3755 2850

C
-

D
-

Total
2500 2900 3800 5400 4400 5100 5700 5700 5700 5700 5700 5700

Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. COP W W Ml W W W A A A
1300 1300 1300 1450 1450 1450 1500 1500 1500 1500 1500 1500 2500 2900 3800 5400 4400 5100 5700 5700 5700 5700 5700 5700 2990 3340 4370 5600 4750 5460 6300 6400 6300 6300 6400 6300 320 320 320 340 350 350 350 350 350 350 350 350 880 1030 1300 1810 1220 1410 1520 1440 1550 1480 1400 1470 1010 1290 1620 2060 1390 1610 1950 1830 2060 1940 1830 1890 1.7 1.7 1.7 1.8 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 4 4.7 5.9 8.3 5.6 6.5 7 6.6 7.1 6.8 6.4 6.7 4.6 5.9 7.4 9.4 6.4 7.4 8.9 8.4 9.4 8.9 8.4 8.6 2.84 2.82 2.92 2.98 3.61 3.62 3.75 3.96 3.68 3.85 4.07 3.88

3 Unit

2200 2200 2200 2900 2900

1 Unit

Note

2 Unit

Specifications are subject to change without prior notice for product improvement.

Note

Specifications are subject to change without prior notice for product improvement.
2008 SAMSUNG DVM Air Conditioners Outdoor Units

Outdoor Units - Free Joint Multi

56

57

Capacity Combination
MH070FXEA4B
Number of Unit Indoor Unit Combination A
2000

Cooling
Cooling Capacity(W) Total
2000 2600 3500 5200 4000 4600 5500 7200 5200 6100 7800 7000 8700

MH070FXEA4B
Number of Unit Indoor Unit Combination A
2200

Heating
Heating Capacity(W) Total
2200 2600 3800 5600 4400 5100 6000 7800 5800 6700 8500 7600 9400

Capacity

Power Consumption

Current EG
B B B A A A A A B A A A A A A A A A A A A A A A A A A A A A A A A A A A

Capacity

Power Consumption

Current EG
E E D

B
2000 2600 3500 5200 2600 3500 5200 3500 5200 5200 2000 2000 2000 2000 2600 2600 2600 3500 3500 2600 2600 2600 3500 3500 2000 2000 2000 2000 2000 2600 2600 2600

C
2000 2600 3500 5200 2600 3500 5200 3500 5200 2600 3500 5200 3500 3500 2000 2000 2000 2600 2600 2600 2600 2600

D
-

%
29% 37% 50% 74% 57% 66% 79% 103% 74% 87% 111% 100% 124%

A
2400 2600 3500 5200 2000 2000 2000 1944 2600 2600 2333 3500 2816 3500 2000 2000 1781 1522 1847 1664 1429 1516 1308 2240 2029 1750 1896 2330 1680 1577 1474 1522 1386 1429 1308 1750

B
2000 2600 3500 5056 2600 3500 4667 3500 4184 3500 2000 2000 1781 1522 2401 2163 1857 2652 2290 2240 2029 1750 2552 2330 1680 1577 1474 1522 1386 1857 1701 1750

C
2000 2600 3118 3957 2401 3119 3714 2652 3120 2240 2732 3121 2552 2330 1680 1577 1474 1978 1802 1857 1701 1750

D
1680 2050 2579 1978 2426 1857 2290 1750

Total
2400 2600 3500 5200 4000 4600 5500 7000 5200 6100 7000 7000 7000 7000 6000 6600 6680 7000 6650 6740 7000 6820 7000 6720 6790 7000 7000 6990 6720 6780 7000 7000 7000 7000 7000 7000

Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. COP W W Ml W W W A A A
1350 1350 1350 1400 1500 1690 1770 1900 1750 1820 1900 1900 1900 1900 1810 1870 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 2400 2600 3500 5200 4000 4600 5500 7000 5200 6100 7000 7000 7000 7000 6000 6600 6680 7000 6650 6740 7000 6820 7000 6720 6790 7000 7000 6990 6720 6780 7000 7000 7000 7000 7000 7000 3000 3480 4200 6240 4800 5520 6600 8400 6240 7320 8400 8400 8900 8900 7200 7920 8020 8900 7980 8080 8900 8180 8900 8050 8150 8900 8900 8900 8070 8140 8900 8900 8900 8900 8900 8900 380 390 400 420 410 420 430 580 420 440 580 580 580 580 440 440 580 580 580 580 580 580 580 580 580 580 580 580 580 580 580 580 580 580 580 580 780 840 1130 1520 1240 1430 1710 2180 1660 1880 2130 2120 2110 2000 1800 1830 1835 1850 1830 1840 1880 1850 1930 1840 1850 1880 1880 1900 1850 1880 1900 1880 1900 1900 1930 1900 950 1100 1580 2160 1490 1720 2050 2520 2000 2260 2540 2530 2540 2540 2280 2460 2410 2460 2410 2460 2460 2510 2510 2420 2460 2510 2460 2510 2460 2460 2460 2460 2510 2460 2550 2550 1.7 1.8 1.8 1.9 1.9 1.9 2 2.7 1.9 2 2.7 2.7 2.7 2.7 2 2 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 3.6 3.8 5.2 7 5.7 6.5 7.8 10 7.6 8.6 9.7 9.7 9.7 9.2 8.2 8.4 8.4 8.5 8.4 8.4 8.6 8.5 8.8 8.4 8.5 8.6 8.6 8.7 8.5 8.6 8.7 8.6 8.7 8.7 8.8 8.7 4.3 5 7.2 9.9 6.8 7.9 9.4 11.5 9.2 10.3 11.6 11.6 11.6 11.6 10.4 11.3 11 11.3 11 11.3 11.3 11.5 11.5 11.1 11.3 11.5 11.3 11.5 11.3 11.3 11.3 11.3 11.5 11.3 11.7 11.7 3.08 3.10 3.10 3.42 3.23 3.22 3.22 3.21 3.13 3.24 3.29 3.30 3.32 3.50 3.33 3.61 3.64 3.78 3.63 3.66 3.72 3.69 3.63 3.65 3.67 3.72 3.72 3.68 3.63 3.61 3.68 3.72 3.68 3.68 3.63 3.68

B
2200 2900 3800 5600 2900 3800 5600 3800 5600 5600 2200 2200 2200 2200 2900 2900 2900 3800 3800 2900 2900 2900 3800 3800 2200 2200 2200 2200 2200 2900 2900 2900

C
2200 2900 3800 5600 2900 3800 5600 3800 5600 2900 3800 5600 3800 3800 2200 2200 2200 2900 2900 2900 2900 2900

D
-

%
26% 30% 44% 65% 51% 59% 70% 91% 67% 78% 99% 88% 109%

A
2500 2900 3800 5600 2200 2200 2200 2200 2900 2900 2729 3800 3283 4250 2200 2200 2200 1892 2200 2042 1768 1872 1631 2750 2516 2188 2375 2867 2063 1927 1819 1855 1705 1736 1603 2150

B
2200 2900 3800 5600 2900 3800 5271 3800 4837 4250 2200 2200 2200 1892 2900 2691 2331 3234 2817 2750 2516 2188 3112 2867 2063 1927 1819 1855 1705 2288 2114 2150

C
2200 2900 3800 4816 2900 3119 4501 3234 3120 2750 3297 3121 3112 2867 2063 1927 1819 2445 2247 2288 2114 2150

D
2063 2540 3142 2445 2944 2288 2769 2150

Total
2500 2900 3800 5600 4400 5100 6000 7800 5800 6700 8000 7600 8120 8500 6600 7300 8200 8600 8000 8260 8600 8340 8600 8250 8330 8600 8600 8600 8250 8320 8600 8600 8600 8600 8600 8600

Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. COP W W Ml W W W A A A
1790 1820 1930 2080 1980 2040 2110 2200 2100 2170 2200 2200 2200 2200 2170 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2500 2900 3800 5600 4400 5100 6000 7800 5800 6700 8000 7600 8120 3220 3680 4600 6440 5060 5870 6900 9130 6670 8040 9600 9120 9740 580 590 600 610 600 610 610 620 610 610 620 620 620 620 610 620 620 620 620 620 620 620 620 620 620 620 620 620 620 620 620 620 620 620 620 620 950 1100 1250 1670 1220 1410 1760 2150 1600 1940 2210 2100 2250 2250 1830 1880 1930 1960 1900 1930 1970 1950 2000 1930 1950 1980 1980 2000 1930 1950 2000 1970 2000 2000 2000 2000 1330 1500 1810 2370 1530 1700 2110 2700 1930 2330 2650 2510 2700 2740 2530 2590 2660 2700 2620 2660 2720 2690 2760 2660 2690 2730 2730 2760 2660 2690 2760 2720 2760 2760 2760 2760 2.7 2.7 2.7 2.8 2.7 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 4.3 5 5.7 7.6 5.6 6.5 8.1 9.8 7.3 8.9 10.1 9.6 10.3 10.3 8.4 8.6 8.8 9 8.7 8.8 9 8.9 9.2 8.8 8.9 9.1 9.1 9.2 8.8 8.9 9.2 9 9.2 9.2 9.2 9.2 6.1 6.9 8.3 10.8 7 7.8 9.7 12.4 8.8 10.7 12.1 11.5 12.4 12.5 11.6 11.9 12.2 12.4 12 12.2 12.4 12.3 12.6 12.2 12.3 12.5 12.5 12.6 12.2 12.3 12.6 12.4 12.6 12.6 12.6 12.6 2.63 2.64 3.04 3.35 3.61 3.62 3.41 3.63 3.63 3.45 3.62 3.62 3.61 3.78 3.61 3.88 4.25 4.39 4.21 4.28 4.37 4.28 4.30 4.27 4.27 4.34 4.34 4.30 4.27 4.27 4.30 4.37 4.30 4.30 4.30 4.30

1 Unit

2600 3500 5200 2000 2000 2000 2000

1 Unit

2600 3800 5600 2200 2200 2200 2200

Outdoor Units

C A A B A A B A A A A A A A A A A A A A A A A A A A A A A A A A A

2 Unit

2600 2600 2600 3500 3500 5200 2000 2000 2000 2000 2000 2000 2000

2 Unit

2900 2900 2900 3800 3800 5600 2200 2200 2200 2200 2200 2200

149% 10400 86% 94% 107% 131% 103% 116% 140% 129% 6000 6600 7500 9200 7200 8100 9800 9000

130% 11200 77% 85% 95% 6600 7300 8200

8500 10200 6600 7300 8200 7590 8400 9590

116% 10000 93% 103% 8000 8900

8600 10300 8000 8260 9360 9670

3 Unit

3 Unit

2200 2200 2200 2900 2900 2900 2900 3800 2200 2200 2200 2200

124% 10700 114% 9800

8600 10300 8340 9760

2000 2000 2600 2600 2600 2600 3500 2000 2000 2000 2000

153% 10700 111% 124% 7800 8700

135% 11600 101% 112% 8700 9600

8600 10300 8250 8330 9650 9740

149% 10400 137% 9600

133% 11400 122% 10500 133% 11400 8800 9500

8600 10300 8600 10300 8600 10300 8250 8320 9660 9730

150% 10500 8000 8600 9500 9200

2000 114% 2600 123% 3500 136% 2600 131%

2200 102% 2900 110%

3800 121% 10400 2900 119% 10200 3800 129% 11100 2900 127% 10900 3800 137% 11800 2900 135% 11600

8600 10300 8600 10300 8600 10300 8600 10300 8600 10300 8600 10300

4 Unit

2000 2000 2000 2600

3500 144% 10100 2600 140% 9800

4 Unit

2200 2200 2200 2900

3500 153% 10700 2600 149% 10400

Note

Note

Specifications are subject to change without prior notice for product improvement.

Specifications are subject to change without prior notice for product improvement.

2008 SAMSUNG DVM Air Conditioners

Outdoor Units

Outdoor Units - Free Joint Multi

58

59

Capacity Combination
MH080FXEA4B
Number of Unit Indoor Unit Combination A
2000

Cooling
Cooling Capacity(W) Total
2000 2600 3500 5200 4000 4600 5500 7200 5200 6100 7800 7000 8700

MH080FXEA4B
Number of Unit Indoor Unit Combination A
2200

Heating
Heating Capacity(W) Total
2200 2900 3800 5600 4400 5100 6000 7800 5800 6700 8500 7600 9400

Capacity

Power Consumption

Current EG
B B B A A A A A B A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A

Capacity

Power Consumption

Current EG
E E D

B
2000 2600 3500 5200 2600 3500 5200 3500 5200 5200 2000 2000 2000 2000 2600 2600 2600 3500 3500 2600 2600 2600 3500 3500 3500 3500 2000 2000 2000 2000 2000 2000 2000 2000 2600 2600 2600 2600 2600 2600

C
2000 2600 3500 5200 2600 3500 5200 3500 5200 2600 3500 5200 3500 5200 3500 5200 2000 2000 2000 2000 2600 2600 2600 3500 2600 2600 3500 2600 2600 3500

D
-

%
25% 33% 44% 65% 50% 58% 69% 90% 65% 76% 98% 88% 109%

A
2400 2600 3500 5200 2000 2000 2000 2000 2600 2600 2400 3500 2957 3825 2000 2000 2000 1663 2000 1864 1573 1698 1495 2510 2274 1940 2083 1841 2667 2295 1888 1767 1617 1429 1663 1531 1356 1455 1573 1495 1379 1940 1841 1705

B
2000 2600 3500 5200 2600 3500 4800 3500 4393 3825 2000 2000 2000 1663 2600 2423 2046 2971 2617 2510 2274 1940 2804 2478 2667 2295 1888 1767 1617 1429 1663 1531 1356 1455 2046 1944 1793 1940 1841 1705

D
-

Total
2400 2600 3500 5200 4000 4600 5500 7200 5200 6100 7200 7000 7350 7650 6000 6600 7500 7650 7200 7550 7710 7640 8000 7530 7610 7760 7690 8000 8000 8000 7550 7600 7680 8000 7650 7730 8000 8000 7710 8000 8000 7760 8000 8000

Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. COP W W Ml W W W A A A
1470 1520 1600 1750 1640 1690 1770 1900 1750 1820 1900 1900 1900 1900 1810 1870 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 2400 2600 3500 5200 4000 4600 5500 7200 5200 6100 7200 7000 7350 7650 6000 6600 7500 7650 7200 7550 7710 7640 8000 7530 7610 7760 7690 8000 8000 8000 7550 7600 7680 8000 7650 7730 8000 8000 7710 8000 8000 7760 8000 8000 3000 3480 4200 6240 4800 5520 6600 8640 6240 7320 8640 8400 8820 9180 7200 7920 9000 9180 8640 9060 9250 9160 9300 9030 9130 9300 9230 9300 9300 9300 9050 9120 9220 9300 9180 9280 9300 9300 9250 9300 9300 9300 9300 9300 380 390 400 420 410 420 430 580 420 440 580 580 580 580 440 440 580 580 580 580 580 580 580 580 580 580 580 580 580 580 580 580 580 580 580 580 580 580 580 580 580 580 580 580 780 840 1130 1520 1240 1430 1710 2240 1660 1900 2240 2180 2290 2380 1850 2000 2220 2190 2150 2150 2190 2190 2260 2110 2140 2210 2180 2260 2260 2300 2140 2140 2180 2300 2190 2200 2300 2280 2190 2260 2300 2220 2300 2300 950 1100 1580 2160 1490 1720 2050 2690 2000 2260 2690 2620 2750 2860 2310 2500 2780 2730 2680 2690 2730 2730 2820 2640 2690 2780 2730 2870 2820 2910 2690 2690 2730 2870 2730 2780 2870 2870 2730 2820 2870 2780 2870 2910 1.7 1.8 1.8 1.9 1.9 1.9 2 2.7 1.9 2 2.7 2.7 2.7 2.7 2 2 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 3.6 3.8 5.2 7 5.7 6.5 7.8 10.3 7.6 8.7 10.3 10 10.5 10.9 8.5 9.2 10.2 10 9.8 9.8 10 10 10.3 9.7 9.8 10.1 10 10.3 10.3 10.5 9.8 9.8 10 10.5 10 10.1 10.5 10.4 10 10.3 10.5 10.2 10.5 10.5 4.3 5 7.2 9.9 6.8 7.9 9.4 12.3 9.2 10.3 12.3 12 12.6 13.1 10.6 11.4 12.7 12.5 12.3 12.3 12.5 12.5 12.9 12.1 12.3 12.7 12.5 13.1 12.9 13.3 12.3 12.3 12.5 13.1 12.5 12.7 13.1 13.1 12.5 12.9 13.1 12.7 13.1 13.3 3.08 3.10 3.10 3.42 3.23 3.22 3.22 3.21 3.13 3.21 3.21 3.21 3.21 3.21 3.24 3.30 3.38 3.49 3.35 3.51 3.52 3.49 3.54 3.57 3.56 3.51 3.53 3.54 3.54 3.48 3.53 3.55 3.52 3.48 3.49 3.51 3.48 3.51 3.52 3.54 3.48 3.50 3.48 3.48

B
2200 2900 3800 5600 2900 3800 5600 3800 5600 5600 2200 2200 2200 2200 2900 2900 2900 3800 3800 2900 2900 2900 3800 3800 3800 3800 2200 2200 2200 2200 2200 2200 2200 2200 2900 2900 2900 2900 2900 2900

C
2200 2900 3800 5600 2900 3800 5600 3800 5600 2900 3800 5600 3800 5600 3800 5600 2200 2200 2200 2200 2900 2900 2900 3800 2900 2900 3800 2900 2900 3800

D
2200

%
24% 31% 41% 60% 47% 55% 65% 84% 62% 72% 91% 82% 101%

A
2500 2900 3800 5600 2200 2200 2200 2200 2900 2900 2729 3800 3283 4250 2200 2200 2200 1896 2200 2109 1785 1931 1764 2840 2595 2226 2392 2193 2910 2677 2130 1987 1830 1677 1864 1726 1586 1610 1754 1633 1611 2188 2158 2013

B
2200 2900 3800 5600 2900 3800 5271 3800 4837 4250 2200 2200 2200 1896 2900 2779 2353 3335 3047 2840 2595 2226 3134 2873 2910 2677 2130 1987 1830 1677 1864 1726 1586 1610 2312 2153 2124 2188 2158 2013

C
2200 2900 3800 4827 2900 3642 4543 3335 4490 2840 3400 4298 3134 4234 2910 3945 2130 1987 1830 1677 2456 2276 2091 2780 2312 2153 2783 2188 2158 2637

D
2130 2619 3161 4269 2456 2982 4037 2780 2312 2821 2783 2188 2827 2637

Total
2500 2900 3800 5600 4400 5100 6000 7800 5800 6700 8000 7600 8120 8500 6600 7300 8200 8620 8000 8530 8680 8600 9300 8520 8590 8750 8660 9300 8730 9300 8520 8580 8650 9300 8640 8710 9300 8780 8690 8760 9300 8750 9300 9300

Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. COP W W Ml W W W A A A
1790 1820 1930 2080 1980 2040 2110 2200 2100 2170 2200 2200 2200 2200 2170 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2500 2900 3800 5600 4400 5100 6000 7800 5800 6700 8000 7600 8120 8500 6600 7300 8200 3220 3680 4600 6440 5060 5870 6900 9130 6670 7710 9360 8740 9500 9950 7590 8400 9590 580 590 600 610 600 610 610 620 610 610 620 620 620 620 610 620 620 620 620 620 620 620 620 620 620 620 620 620 620 620 620 620 620 620 620 620 620 620 620 620 620 620 620 620 950 1110 1250 1670 1220 1410 1760 2150 1600 1940 2210 2090 2250 2340 1830 1950 2150 2140 2080 2100 2140 2140 2150 2090 2100 2140 2140 2150 2150 2180 2100 2100 2140 2200 2140 2140 2200 2180 2140 2180 2200 2140 2180 2200 1330 1500 1810 2370 1530 1700 2110 2580 1930 2330 2600 2510 2650 2750 2220 2340 2570 2610 2500 2690 2740 2740 2750 2680 2690 2740 2740 2750 2750 2790 2690 2690 2740 2820 2740 2740 2820 2790 2740 2790 2820 2740 2790 2820 2.7 2.7 2.7 2.8 2.7 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 4.3 5.1 5.7 7.6 5.6 6.5 8.1 9.8 7.3 8.9 10.1 9.6 10.3 10.7 8.4 8.9 9.8 9.8 9.5 9.6 9.8 9.8 9.8 9.6 9.6 9.8 9.8 9.8 9.8 10 9.6 9.6 9.8 10.1 9.8 9.8 10.1 10 9.8 10 10.1 9.8 10 10.1 6.1 6.9 8.3 10.8 7 7.8 9.7 11.8 8.8 10.7 11.9 11.5 12.1 12.6 10.2 10.7 11.8 11.9 11.4 12.3 12.5 12.5 12.6 12.3 12.3 12.5 12.5 12.6 12.6 12.8 12.3 12.3 12.5 12.9 12.5 12.5 12.9 12.8 12.5 12.8 12.9 12.5 12.8 12.9 2.63 2.61 3.04 3.35 3.61 3.62 3.41 3.63 3.63 3.45 3.62 3.64 3.61 3.63 3.61 3.74 3.81 4.03 3.85 4.06 4.06 4.02 4.33 4.08 4.09 4.09 4.05 4.33 4.06 4.27 4.06 4.09 4.04 4.23 4.04 4.07 4.23 4.03 4.06 4.02 4.23 4.09 4.27 4.23

1 Unit

2600 3500 5200 2000 2000 2000 2000

2000 2600 3500 4324 2600 3262 4091 2971 3888 2510 3061 3880 2804 3681 2667 3410 1888 1767 1617 1429 2162 1990 1763 2545 2046 1944 2414 1940 1841 2295

1888 2298 2829 3714 2162 2679 3525 2545 2046 2617 2414 1940 2478 2295

1 Unit

2900 3800 5600 2200 2200 2200 2200

Outdoor Units

C A A B A A B A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A

2 Unit

2600 2600 2600 3500 3500 5200 2000 2000 2000 2000 2000 2000 2000

2 Unit

2900 2900 2900 3800 3800 5600 2200 2200 2200 2200 2200 2200 2200

130% 10400 75% 83% 94% 115% 90% 101% 123% 113% 6000 6600 7500 9200 7200 8100 9800 9000

120% 11200 71% 78% 88% 6600 7300 8200

108% 10000 86% 96% 8000 8900

8620 10090 8000 8530 9360 9980

115% 10700 105% 9800

8680 10150 8600 10070 9300 10900 8520 9960

3 Unit

2000 2000 2600 2600 2600 2600 2600 3500 3500 2000 2000 2000 2000 2000 2000

3 Unit

2200 2200 2900 2900 2900 2900 2900 3800 3800 2200 2200 2200 2200 2200 2200

134% 10700 98% 109% 7800 8700

125% 11600 94% 103% 8700 9600

8590 10050 8750 10900 8660 10130 9300 10900 8730 10220 9300 10900 8520 9970

130% 10400 120% 9600

123% 11400 113% 10500 132% 12300 123% 11400 142% 13200 95% 8800 9500

141% 11300 131% 10500 153% 12200 8000 8600 9500

2000 100% 2600 108% 3500 119%

2900 102%

8580 10040 8650 10120 9300 10900 8640 10100 8710 10190 9300 10900 8780 10270 8690 10170 8760 10250 9300 10900 8750 10240 9300 10900 9300 10900

3800 112% 10400 5600 131% 12200 2900 110% 10200 3800 119% 11100 5600 139% 12900 3800 129% 12000 2900 117% 10900 3800 127% 11800 3800 137% 12700 2900 125% 11600 3800 134% 12500 3800 144% 13400

5200 140% 11200 2600 115% 9200

3500 126% 10100 5200 148% 11800 3500 138% 11000 2600 123% 9800

4 Unit

2000 2000 2000 2000 2000 2600 2600 2600

4 Unit

2200 2200 2200 2200 2200 2900 2900 2900

3500 134% 10700 3500 145% 11600 2600 130% 10400 3500 141% 11300 3500 153% 12200

Note

Note

Specifications are subject to change without prior notice for product improvement.

Specifications are subject to change without prior notice for product improvement.

2008 SAMSUNG DVM Air Conditioners

Outdoor Units

Indoor Units

60

61

Indoor Units

imagine
the perfect fit
Different types of air conditioners are required depending on different types of buildings and residential space. Searching for the right air conditioner for your commercial and residential space is over. Youll be able to find the one you need from Samsungs variety of indoor units in style. Perfect fit, just the way you need it.

Indoor Units

>> 62_ Wall-mounted Type >64_ MB >66_ Vivace >68_ Neo Forte >> 70_ Cassette Type >72_ Slim 1Way Cassette >76_ 2Way Cassette >78_ Mini 4Way Cassette >80_ 4Way Cassette >> 84_ Duct Type >86_ Slim Duct >90_ MSP Duct >> 92_ Floor & Convertible >94_ Console >98_ Ceiling >> 100_ ERV System >> 104_ Accessories

Indoor Units - Wall-mounted type

62

63

MPI Zone (Optional)


Do you know that harmful substances and viruses breed in the space you live in?

How Micro Plasma Ion System technology Works

Micro Plasma Ion improves your Indoor Air Quality and eliminates all your worries.
q Creation

Active hydrogen / Oxygen ions


Active hydrogen and oxygen ions are generated

Harmful substances
Combines with Harmful substances OH radical, Harmful viruses and bacteria.

Harmless water
Turns into harmless water

of an Intensely Purified Zone against disease q Safe from allergy-causing agents q Controls active oxygen which can cause disease, cancer, and accelerated aging
q Protection

Indoor Units

Health Care System (Optional)


Health Care System
Stage 1

5-Step Air Purifying System


Step 5
MPI Zone (Optional)

The Samsung air conditioner is all what you need to keep your air consistently clean and fresh.
Stage 1 Auto Roof Shutter(MB)
The Auto Roof Shutter keeps dirt from getting inside.

Step 4
Deodorizing filter

Stage 3

Stage 2 MPI (Micro Plasma Ion )


Biological contaminants and various pathogens such as bacteria, viruses, and molds are removed.

Step 3
DNA or Catechin Filter

Stage 2

Stage 3 DNA filter & 5 step filter


Exogenous endocrine-disrupting chemicals, hazardous materials, and other harmful chemicals are removed.

Step 2
Silver Coated Evaporator (Optional)

Wall-mounted type Air conditioners


Samsungs brand new wall-mounted type air conditioners have more than just a feature of comfortable cooling. New wall-mounted air conditioners will be part of your interior design and protect your health with built-in health care system. Breathe cooler and healthier air every second of your life.

Step 1
Silver Coated Filter

Goodsleep II (MB/Forte)
Best Temperature for deep sleep
According to the stage of sleep, temperatures are adjusted so you fall into deep sleep faster and get up more refreshed in the morning for a great start to your day.
1. Falling asleep stage: Eases you into sleep by dropping the temperature. 2. Sound sleep stage: Relaxes your body and raises your temperature slightly. 3. Wake up stage: Allows you to wake up from comfortable intermittent air and it makes you feel refresh.

2008 SAMSUNG DVM Air Conditioners

Indoor Units

Indoor Units - Wall-mounted type

64

65

Unique and Innovative

MB

Optional Accessories

Individual Controllers

MWR-TH01

MWR-WS00

MWR-SH00

MR-BH01

Specification |
Model Power Source Mode *
1)

MB
AVXWBH028EE /V/Hz 1/220~240/50 HP/HR AVXWBH036EE 1/220~240/50 HP/HR 3.6 12,200 4.0 13,600 30 0.19
5)

AVXWBH056EE 1/220~240/50 HP/HR 5.6 19,100 6.3 21,400 50 0.3

AVXWBH071EE 1/220~240/50 HP/HR 6.8 23,200

Performance

Capacity

Cooling *

2)

kW Btu/h

2.8 9,500 3.2 10,900 30 0.18 31 / 20 *

Indoor Units

Heating *

3)

kW Btu/h

7.0 23,800 50 0.3


5)

power

Input Running Current

W A
4)

Sound Fan Airflow Rate

Sound Pressure (High/Low) * Type Cooling (High) Heating (High)

dB(A) m3/min m3/min ,mm ,mm ,mm kg kg mm mm -

35 / 21 *

5)

40 / 30 *

41 / 30 *5) Cross Flow Fan R410A EEV *6) 9.52 15.88 ID 18 hose 13.0 *5) 16.0 *5) 1,100x307x225 1,157x381x292 Filter (Washable) ARH-1364

Cross Flow Fan 8.14 *


5)

Cross Flow Fan 9.16 * 9.46 *


5)

Cross Flow Fan 14.98 * 14.49 *


5)

8.23 *

5)

5)

5)

Refrigerant

Type Control Method

R410A EEV *
6)

R410A EEV *
6)

R410A EEV *
6)

Piping Connections

Liquid (Flare) Gas (Flare) Drain (Quick Lock)

6.35 12.70 ID 18 hose 10.2 *


5)

6.35 12.70 ID 18 hose 10.2 *


5)

6.35 12.70 ID 18 hose 13.0 *


5)

Auto Roof Shutter (2.8/3.6kW)


This unique air conditioner automatically seals off to prevent dirt infiltration when not in operation.

DNA Filter
It is a new technology that screens selectively for only toxic agents. This enables a smarter and effective air management compared to other filters.

Weight

Net Weight Shipping Weight

11.5 *5) 900x304x185 963x349x247 Filter (Washable) ARH-1364

11.5 *5) 900x304x185 963x349x247 Filter (Washable) ARH-1364

16.0 *5) 1,100x307x225 1,157x381x292 Filter (Washable) ARH-1364

Set Size

Net Dimensions (WxHxD) Shipping Dimensions (WxHxD)

MPI (Micro Plasma Ion)


The world's first technology that generates active hydrogen atoms together with oxygen ions to improve your Indoor Air Quality. It protects you from harmful particles and viruses existing in the air.

Goodsleep II
Innovative technology developed to control the air temperature during your sleep and maintain optimum skin temperature to enjoy a comfortable sleep and also a refreshed wake up.

Standard Accessories

Filter / Safety Grille Wireless Remote Controller

Notes

Deodorizing filter
Incorporated with activated carbon, the Deodorizing Filter efficiently adsorbs cigarette smoke, pet odors and other unpleasant odors.

Silver Coated Evaporator


The fins of the evaporator are triple coated with environmentally friendly materials (2 years of chrome-free silica, 1 layer of Silver coating) to ensure efficient removal of condensation and to guarantee the production of clean and fresh air.

*1) Mode: HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on: Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on: Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications are subject to change without prior notice for product improvement. *6) Optional Accessory

Design

Blue Light

Pearl Color

Auto Roof Shutter

2008 SAMSUNG DVM Air Conditioners

Indoor Units

Indoor Units - Wall-mounted type

66

67

Chic and Graceful

Vivace (Shadow Mirror)

Optional Accessories

Individual Controllers

MWR-TH01

MWR-WS00

MWR-SH00

MR-BH01

Specification |
Model Power Source Mode *
1)

Vivace
AVXWVH022EE AVXWVH028EE AVXWVH036EE AVXWVH056EE AVXWVH071EE /V/Hz 1/220~240/50 HP/HR 1/220~240/50 HP/HR 2.8 9,500 3.2 10,900 30 0.18
5)

1/220~240/50 HP/HR 3.6 12,200 4.0 13,600 35 0.19 35 / 21 Cross Flow Fan 8.2 8.8 R410A EEV * 6.35 12.70 ID 18 hose 8.5 11.5 825x285x189 900x349x252 Filter (Washable) ARH-1364
6)

1/220~240/50 HP/HR 5.6 19,100 6.3 21,400 50 0.30 40 / 30 Cross Flow Fan 13.3 14.0 R410A EEV * 6.35 12.70 ID 18 hose 12.0 15.0 1,065x298x218 1,137x377x299 Filter (Washable) ARH-1364
6)

1/220~240/50 HP/HR 6.8 23,200 7.0 23,800 50 0.30 41 / 30 Cross Flow Fan 13.3 14.0 R410A EEV *6) 9.52 15.88 ID 18 hose 12.0 15.0 1,065x298x218 1,137x377x299 Filter (Washable) ARH-1364

Performance

Capacity

Cooling *

2)

kW Btu/h

2.2 7,500 2.5 8,500 30 0.13 31 / 21 *

Heating *

3)

kW Btu/h

Indoor Units

power

Input Running Current

W A
4)

Sound Fan Airflow Rate

Sound Pressure (High/Low) * Type Cooling (High) Heating (High)

dB(A) m3/min m3/min ,mm ,mm ,mm kg kg mm mm -

31 / 21 Cross Flow Fan 7.0 7.3 R410A EEV * 6.35 12.70 ID 18 hose 8.5 11.5 825x285x189 900x349x252 Filter (Washable) ARH-1364
6)

Cross Flow Fan 8.82 6.11 R410A EEV * 6.35 12.70 ID 18 hose 8.5 11.5 825x285x189 900x349x252 Filter (Washable) ARH-1364
6)

Refrigerant

Type Control Method

Piping Connections

Liquid (Flare) Gas (Flare) Drain (Quick Lock)

MPI (Micro Plasma Ion)


The world's first technology that generates active hydrogen atoms together with oxygen ions to improve your Indoor Air Quality. It protects you from harmful particles and viruses existing in the air.

Weight

Net Weight Shipping Weight

Catechin filter
Catechin, extracted from green tea, is contained in the filter and deactivates captured bacteria and unpleasant odors.
Set Size

Net Dimensions (WxHxD) Shipping Dimensions (WxHxD)

Standard

Filter / Safety Grille Wireless Remote Controller

Deodorizing filter Goodsleep II


Innovative technology developed to control the air temperature during your sleep and maintain optimum skin temperature to enjoy a comfortable sleep and also a refreshed wake up. Incorporated with activated carbon, the Deodorizing Filter efficiently adsorbs cigarette smoke, pet odors and other unpleasant odors.

Accessories

Notes

Silver Coated Evaporator


The fins of the evaporator are triple coated with environmentally friendly materials (2 years of chrome-free silica, 1 layer of Silver coating) to ensure efficient removal of condensation and to guarantee the production of clean and fresh air.

*1) Mode: HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on: Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on: Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications are subject to change without prior notice for product improvement. *6) Optional Accessory

Design

Shadow Mirror

Hidden Display

Trim-less Design

2008 SAMSUNG DVM Air Conditioners

Indoor Units

Indoor Units - Wall-mounted type

68

69

Clean and Fashionable

Neo Forte

Optional Accessories

Individual Controllers

MWR-TH01

MWR-WS00

MWR-SH00

MR-BH01

Specification |
Model Power Source Mode *
1)

Neo Forte
AVXWNH022EE AVXWNH028EE AVXWNH036EE AVXWNH056EE AVXWNH071EE /V/Hz 1/220~240/50 1/220~240/50 1/220~240/50 1/220~240/50 HP/HR HP/HR 2.8 9,500 3.2 10,900 25 0.16
5)

1/220~240/50 HP/HR 6.8 23,200

HP/HR 3.6 12,200 4.0 13,600 30 0.18 36/23 *


5)

HP/HR 5.6 19,100 6.3 21,400 45 0.27 40/30 *


5)

Performance

Capacity

Cooling *

2)

kW Btu/h

2.2 7,500 2.5 8,500 25 0.16 32/23 *

Indoor Units Indoor Units

Heating *

3)

kW Btu/h

7.0 23,800 50 0.30 41/30 *5) Cross Flow Fan 14.45 *5) 14.94 *5) R410A EEV *6) 9.52 15.88 ID 18 hose 12.0 *5) 15.0 *5)

power

Input Running Current

W A
4)

Sound Fan Airflow Rate

Sound Pressure (High/Low) * Type Cooling (High) Heating (High)

dB(A) m3/min m3/min /mm ,mm ,mm kg kg mm mm -

32/23

Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan 7.73 *
5)

8.31 *

5)

9.54 *

5)

13.21 *

5)

8.00 *5) R410A EEV *


6)

8.56 *5) R410A EEV *


6)

9.93 *5) R410A EEV *


6)

14.22 *5) R410A EEV *


6)

Refrigerant

Type Control Method

Piping Connections

Liquid (Flare) Gas (Flare) Drain (Quick Lock)

6.35 12.70 ID 18 hose 8.5 *


5)

6.35 12.70 ID 18 hose 8.5 *


5)

6.35 12.70 ID 18 hose 8.5 *


5)

6.35 12.70 ID 18 hose 12.0 *


5)

Weight

Net Weight Shipping Weight

11.5 *5) 825x285x189 900x349x252 Filter (Washable) ARH-1364

11.5 *5) 825x285x189 900x349x252

11.5 *5)

15.0 *5)

Goodsleep II
Innovative technology developed to control the air temperature during your sleep and maintain optimum skin temperature to enjoy a comfortable sleep and also a refreshed wake up.

Catechin filter
Catechin, extracted from green tea, is contained in the filter and deactivates captured bacteria and unpleasant odors.

Set Size

Net Dimensions (WxHxD) Shipping Dimensions (WxHxD)

825x285x189 1,065x298x218 1,065x298x218 900x349x252 1,137x377x299 1,137x377x299 Filter (Washable) ARH-1364

Standard Accessories

Filter / Safety Grille Wireless Remote Controller

Filter (Washable) Filter (Washable) Filter (Washable) ARH-1364 ARH-1364 ARH-1364

Notes

Silver Coated Evaporator


The fins of the evaporator are triple coated with environmentally friendly materials (2 years of chrome-free silica, 1 layer of Silver coating) to ensure efficient removal of condensation and to guarantee the production of clean and fresh air.

Deodorizing filter
Incorporated with activated carbon, the Deodorizing Filter efficiently adsorbs cigarette smoke, pet odors and other unpleasant odors.

*1) Mode: HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on: Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on: Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications are subject to change without prior notice for product improvement. *6) Optional Accessory

Design

Clean-Cut Front Panel

Silver Accent Line

Bottom Opening Front Panel

2008 SAMSUNG DVM Air Conditioners

Indoor Units

Indoor Units - Cassette type

70

71

WIDE WIDE

Wide Blade
The new cassette type air conditioner is equipped with uniquely designed blades that are wider to provide even cooling and heating power throughout the room.

Cassette type Air conditioners


This year's new cassette type air conditioner still boasts its slim and compact size, but is now equipped with more advanced features. The cassette type air conditioner not only has stronger airflow to cool and heat every inch of space efficiently, but is also designed to be quiet and to purify. Expect more with Samsung.

64mm

WIDER
46mm

Indoor Units

Cassette type Icon


WIDE BLADE
WIDE WIDE

Ceiling Soiling Prevention


HIGH

New Blade

Conventional Blade

CEILING SOILING PREVENTION

HIGH LIFT-UP DRAIN PUMP QUICK CONNECTION OF DRAIN PIPE

Newly designed panel will control the air direction to avoid having contact with the ceiling. This new design will prevent the ceiling soiling and keep your interior cleaner than ever even, after long period of operation.

Ceiling

Ceiling

FRESH

FRESH AIR INTAKE

SUB DUCT
SUB DUCT QUICK

Airflow is directed downwards without having contact with the ceiling.

Airflow is directed towards the ceiling which cause ceiling soiling.

HIGH

High Lift-up Drain Pump

FRESH

Fresh Air Intake

The lift-up drain pump lifts condensed water up to 750mm, compared to the competitors 700mm, allowing for flexible and convenient installation.
Lift-up Range
750mm
700mm (mm) 600 650 700 750

With optional installation of an air intake motor, fresh air can enter through the cassette unit so you have fresher air in the room.
Motor Fresh air

SUB DUCT

Sub Duct

QUICK

Quick Connection of Drain Pipe


Company A

The Sub Duct lets you use the same air conditioner unit to cool another smaller space nearby. (The cassette unit is fitted with a knock-out component to accommodate this.)

Samsung's unique drain pipe prevents leaks and is easier to install with no need to use tape or adhesives.
Samsung

Office 2008 SAMSUNG DVM Air Conditioners

Fitting room Indoor Units

Indoor Units - Cassette type

72

73

Stylish and Slim

Slim and Compact Design


Slim 1Way Cassette
Want a cassette type air conditioner, but have limited space? Samsung's new Slim 1Way cassette type air conditioner is the answer.

Slim 1Way Cassette

Only 135mm thick


Samsung introduces the world's slimmest indoor air conditioner unit. Only 135mm thick, the slim 1Way Cassette air conditioner can be installed practically anywhere. NOTE
Ensure that there is sufficient installation space. Allow at least 170mm for the installation.

135mm

Indoor Units

Min. 170mm

Lighter indoor unit


The first to apply ABS cabinets into its indoor units, Samsung has achieved the lightest units on the market. Its slim lightweight design makes installation and maintenance a breeze.
10.5kg

38% Down
17kg

4kW R410A model

Weight

Quiet Operation
Samsung's new blade design drastically reduces noise levels, so you can relax in peace and quiet.
25dB

Low
35dB

30dB

High
43dB

Fan speed

Noise level

WIDE BLADE
WIDE WIDE

CEILING SOILING PREVENTION

HIGH

HIGH LIFT-UP DRAIN PUMP

QUICK

QUICK CONNECTION OF DRAIN PIPE

Check Valve Inside Drain Pump


Faulty drainage installation or power failures can cause condensed water to flow back into the unit, causing leakage and odors. Samsung's air conditioners are equipped with a check valve built directly into the drain pump to prevent water from flowing backward.
Check Valve

Optional Accessories

Individual Controllers

Panel

MWR-TH01

MWR-WS00

MWR-SH00

MR-BH01

MR-AH01

PSSMA

2008 SAMSUNG DVM Air Conditioners

Indoor Units

Indoor Units - Cassette type

74

75

Specification |
Model Power Source Mode *1) Performance Capacity

Slim 1Way Cassette


AVXCSH022EE /V/Hz 1/220~240/50 HP/HR Power Source Mode *1) Performance Capacity Cooling *
2)

Model /V/Hz

AVXCSH028EE 1/220~240/50 HP/HR kW Btu/h Heating *3) kW Btu/h 2.8 9,500 3.2 10,900 45 0.23 30 / 25 *
5)

AVXCSH036EE 1/220~240/50 HP/HR 3.6 12,200 4.0 13,600 50.5

Cooling *

2)

kW Btu/h

2.2 7,500 2.5 8,500 40 0.20 30/25 *


5)

Heating *3)

kW Btu/h

power

Input Running Current

W A
4)

power

Input Running Current

W A
4)

Indoor Units

0.25 32 / 27 *5) Cross Flow fan 7.5 *5) 9.7 *5) R410A EEV 6.35 12.70 VP20(OD 25,ID 20) 10.5 13.5 970x135x410 1,164x212x478 PSSMA 3.0 5.0 1180x25x460 1259x144x539 Filter (Washable) 24/750

Sound Fan Airflow Rate

Sound Pressure (High/Low) * Type Cooling (High) Heating (High)

dB(A) m /min
3

Sound Fan Airflow Rate

Sound Pressure (High/Low) * Type Cooling (High) Heating (High)

dB(A) m /min
3

Cross Flow Fan 5.4 * 7.6 *


5)

Cross Flow fan 6.0 * 8.6 *


5)

m3/min ,mm ,mm ,mm kg kg mm mm kg kg mm mm l/h / mm

5)

m3/min ,mm ,mm ,mm kg kg mm mm kg kg mm mm l/h / mm

5)

Refrigerant

Type Control Method

R410A EEV 6.35 12.70 VP20(OD 25,ID 20) 10.5 13.5 970x135x410 1,164x212x478 PSSMA 3.0 5.0 1,180x25x460 1,259x144x539 Filter (Washable) 24/750

Refrigerant

Type Control Method

R410A EEV 6.35 12.70 VP20(OD 25,ID 20) 10.5 13.5 970x135x410 1,164x212x478 PSSMA 3.0 5.0 1,180x25x460 1,259x144x539 Filter (Washable) 24/750

Piping Connections

Liquid (Flare) Gas (Flare) Drain (Quick Lock)

Piping Connections

Liquid (Flare) Gas (Flare) Drain (Quick Lock)

Weight

Net Weight Shipping Weight

Weight

Net Weight Shipping Weight

Set Size

Net Dimensions (WxHxD) Shipping Dimensions (WxHxD)

Set Size

Net Dimensions (WxHxD) Shipping Dimensions (WxHxD)

Panel Size

Model Net Weight Shipping Weight Net Dimensions (WxHxD) Shipping Dimensions (WxHxD)

Panel Size

Model Net Weight Shipping Weight Net Dimensions (WxHxD) Shipping Dimensions (WxHxD)

Standard Accessories
Notes

Filter / Safety Grille Drain Pump (Pumping speed / lift)

Standard Accessories
Notes

Filter / Safety Grille Drain Pump (Pumping speed / lift)

*1) Mode: HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on: Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on: Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications are subject to change without prior notice for product improvement.

*1) Mode: HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on: Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on: Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications are subject to change without prior notice for product improvement.

2008 SAMSUNG DVM Air Conditioners

Indoor Units

Indoor Units - Cassette type

76

77

Slim and Compact

2Way Cassette

Optional Accessories

Individual Controllers

Panel

MWR-TH01

MWR-WS00

MWR-SH00

MR-BH01

MR-AH01

P2SMA

Specification |
Model Power Source Mode *1) Performance Capacity

2Way Cassette
AVXC2H056EE /V/Hz 1/220~240/50 HP/HR AVXC2H071EE 1/220~240/50 HP/HR 7.1 24,200 8.0

Cooling *

2)

kW Btu/h

5.6 19,100 6.3 21,400 70 0.38 36 / 28 Cross Flow Fan 14.0 16.0 R410A EEV 6.35 12.70 VP25 (OD 32,ID 25) 21.0 25.0 890x230x575 1,077x299x642 P2SMA 4.0 8.0 1,030x25x650 1,103x151x727 Filter (Washable) 24/750

Heating *3)

kW Btu/h

Indoor Units

27,200 75 0.40 38 / 28 Cross Flow Fan 14.0 16.0 R410A EEV 9.52 15.88 VP25 (OD 32,ID 25) 21.0 25.0 890x230x575 1,077x299x642 P2SMA 4.0 8.0 1,030x25x650 1,103x151x727 Filter (Washable) 24/750

power

Input Running Current

W A dB(A) m3/min m3/min ,mm ,mm ,mm kg kg mm mm kg kg mm mm l/h / mm

Sound Fan Airflow Rate

Sound Pressure (High/Low) *4) Type Cooling (High) Heating (High)

Refrigerant

Type Control Method

Piping Connections

Liquid (Flare) Gas (Flare) Drain (Quick Lock)

Weight

Net Weight Shipping Weight

HIGH

HIGH LIFT-UP DRAIN PUMP

QUICK

QUICK CONNECTION OF DRAIN PIPE

Set Size

Net Dimensions (WxHxD) Shipping Dimensions (WxHxD)

Panel Size

Model Net Weight Shipping Weight Net Dimensions (WxHxD)

Standard Formula for Easy Installation


The dimensions of the 2Way cassette air conditioner allows for easy installation into standard ceiling grids (600Wx600H), so everything just falls into place.
Standard Accessories
600mm

Shipping Dimensions (WxHxD) Filter / Safety Grille Drain Pump (Pumping speed / lift)

Notes

600mm

Small Size Big Performance


The 2Way cassette air conditioner is now 45% smaller than competitors models, so it's even easier to incorporate into building design.
45%
Decreased

Twin Cross Flow Fan


The 2Way cassette type unit is perfect fit for long and narrow rectangular type of space. Twin Cross Flow Fan inside of the 2Way cassette will spread cool or warm air even further and wider with less noise.
Cross flow fans

*1) Mode: HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on: Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on: Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications are subject to change without prior notice for product improvement.

230mm

305mm

575mm

890mm

600mm 1,180mm

2008 SAMSUNG DVM Air Conditioners

Indoor Units

Indoor Units - Cassette type

78

79

Compact and Efficient

Mini 4Way Cassette

Optional Accessories

Individual Controllers

Panel

MWR-TH01

MWR-WS00

MWR-SH00

MR-BH01

MR-AH01

PMSMA

Specification |
Model Power Source Mode *1) Performance Capacity

Mini 4Way Cassette


AVXCMH028EE /V/Hz 1/220~240/50 HP/HR AVXCMH036EE 1/220~240/50 HP/HR 3.6 12,200 4.0 13,600 90 0.50 34 / 27 Turbo Fan 10.1 11.9 R410A EEV 6.35 12.70 VP25 (OD 32,ID 25) 17.0 20.0 575x260x575 660x310x635 PMSMA 3.5 6.2 670x35x670 717x93x717 AVXCMH056EE 1/220~240/50 HP/HR 5.6 19,100 6.3 21,400 95 0.52 41 / 33 Turbo Fan 10.6 12.6 R410A EEV 6.35 12.70 VP25 (OD 32,ID 25) 17.0 20.0 575x260x575 660x310x635 PMSMA 3.5 6.2 670x35x670 717x93x717 AVXCMH060EE 1/220~240/50 HP/HR 6.0 20,400 6.8

Cooling *

2)

kW Btu/h

2.8 9,500 3.2 10,900 90 0.50 30 / 25 Turbo Fan 10.1 11.9 R410A EEV 6.35 12.70 VP25 (OD 32,ID 25) 17.0 20.0 575x260x575 660x310x635 PMSMA 3.5 6.2 670x35x670 717x93x717 Filter / Safety Grille 24/750

Heating *3)

kW Btu/h

Indoor Units

23,200 100 0.55 41 / 33 Turbo Fan 12.2 14.5 R410A EEV 6.35 12.70 VP25 (OD 32,ID 25) 17.0 20.0 575x260x575 660x310x635 PMSMA 3.5 6.2 670x35x670 717x93x717 Filter / Safety Grille 24/750

power

Input Running Current

W A dB(A) m3/min m3/min ,mm ,mm ,mm kg kg mm mm kg kg mm mm l/h / mm

Sound Fan Airflow Rate

Sound Pressure (High/Low) *4) Type Cooling (High) Heating (High)

Refrigerant

Type Control Method

Piping Connections
HIGH LIFT-UP DRAIN PUMP FRESH AIR INTAKE QUICK CONNECTION OF DRAIN PIPE

Liquid (Flare) Gas (Flare) Drain (Quick Lock)

HIGH

FRESH

QUICK

Weight

Net Weight Shipping Weight

Set Size

Net Dimensions (WxHxD) Shipping Dimensions (WxHxD)

Panel Size

Model Net Weight

Ideal Compact Size


The Mini 4Way cassette air conditioner can be installed in one standard ceiling tile (600Wx600H), which can save installation time.

Unit : mm

Shipping Weight Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Standard Accessories
Notes

Filter / Safety Grille Drain Pump (Pumping speed / lift)

Filter / Safety Grille Filter / Safety Grille 24/750 24/750

On : Increased fan speed

Off : Standard fan speed

Fan Speed Adjustment


Fan speed can be adjusted according to ceiling height by adjusting dip switch of indoor units PCB.
3~3.5m 2.7m

*1) Mode: HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on: Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on: Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications are subject to change without prior notice for product improvement.

High Ceiling

Standard Ceiling

2008 SAMSUNG DVM Air Conditioners

Indoor Units

Indoor Units - Cassette type

80

81

Powerful and Silent

New Turbo Fan


Quiet Operation
Imagine a room of cool calmness. The aerodynamically designed Turbo Fan' minimizes noise from the turbulence of blade movement. Therefore noise is less than conventional models.
A View B View C View

4Way Cassette

Uniform Distribution
The new 'Turbo Fan' with wide blades provides extreme cooling and heating power from 4 separate outlets so the entire room gets cool or warm faster. Now, every nook and cranny is comfortable.

Outlet 1 Outlet 2 Outlet 3

Indoor Units

Outlet 4

Easy Leveling
Each corner portion of the panel is detachable, which gives easier access to adjust the height, therefore leveling and installation is much easier and quicker than before.

New 4Way

Conventional 4Way

Detachable corners make installation and height adjustments much easier.

Detaching the whole panel took more time.

Compact Size
WIDE BLADE
WIDE WIDE

CEILING SOILING PREVENTION

HIGH

HIGH LIFT-UP DRAIN PUMP QUICK CONNECTION OF DRAIN PIPE

The 4Way cassette type unit has gotten even slimmer. Now only 218mm thick (5.2/7.0/9.0kW), 24% slimmer compare to competitors 288mm (9.0kW). It's still the industry leader in compactness and is even easier to install in tight spaces.

218mm

FRESH

FRESH AIR INTAKE

SUB DUCT
SUB DUCT QUICK

Stylish Panel Design


The stylish panel is well harmonized with any interior design.

Efficient Cooling
3-dimensional blade, which has the world wide patent, is able to spread cool or warm air further and evenly to all corners of the space.

New 4Way
Air distribution Air distribution

Conventional 4Way

Optional Accessories

Individual Controllers
MWR-TH01 MWR-WS00 MWR-SH00 MR-BH01 MR-AH01

Panel

P4SMA

2008 SAMSUNG DVM Air Conditioners

Indoor Units

Indoor Units - Cassette type

82

83

Specification |
Model Power Source Mode *1) Performance Capacity

4Way Cassette
AVXC4H045EE /V/Hz 1/220~240/50 HP/HR AVXC4H056EE 1/220~240/50 HP/HR 5.6 19,100 6.3 21,400 40 0.19 34/29 Turbo Fan 14.5 16.5 R410A EEV 6.35 12.70 VP25 (OD 32,ID 25) 25.0 31.0 840x218x840 926x280x926 P4SMA 7.0 10.3 950x35x950 1,042x103x1,042 AVXC4H071EE 1/220~240/50 HP/HR 7.1 24,200 8.0 27,200 45 0.21 36/30 Turbo Fan 17.0 18.5 R410A EEV 9.52 15.88 VP25 (OD 32,ID 25) 25.0 31.0 840x218x840 926x280x926 P4SMA 7.0 10.3 950x35x950 1,042x103x1,042 AVXC4H090EE 1/220~240/50 HP/HR 9.0 30,700 10.0 34,100 50 0.23 39/32 Turbo Fan 19.5 21.5 R410A EEV 9.52 15.88 VP25 (OD 32,ID 25) 25.0 31.0 840x218x840 926x280x926 P4SMA 7.0 10.3 950x35x950 1,042x103x1,042 Filter / Safety Grille 24/750 Standard Accessories
Notes

Model Power Source Mode *1) Performance Capacity Cooling *


2)

AVXC4H112EE /V/Hz 1/220~240/50 HP/HR kW Btu/h Heating *3) kW Btu/h 11.2 38,200 12.5 42,600 50 0.23 40 / 33 Turbo Fan 23.0 26.5 R410A EEV 9.52 15.88 VP25 (OD 32,ID 25) 29.0 35.0 840x298x840 926x360x926 P4SMA 7.0 10.3 950x35x950 1,042x103x1,042 Filter / Safety Grille 24/750

AVXC4H128EE 1/220~240/50 HP/HR 12.8 43,600 13.8 47,000 65 0.30 41 / 35 Turbo Fan 25.0 29.5 R410A EEV 9.52 15.88 VP25 (OD 32,ID 25) 29.0 35.0 840x298x840 926x360x926 P4SMA 7.0 10.3 950x35x950 1,042x103x1,042 Filter / Safety Grille 24/750

AVXC4H140EE 1/220~240/50 HP/HR 14.0 47,700 16.0 54,500 80

Cooling *

2)

kW Btu/h

4.5 15,300 5.0 17,000 40 0.19 34/29 Turbo Fan 14.5 16.5 R410A EEV 6.35 12.70 VP25 (OD 32,ID 25) 25.0 31.0 840x218x840 926x280x926 P4SMA 7.0 10.3 950x35x950 1,042x103x1,042 Filter / Safety Grille 24/750

Heating *3)

kW Btu/h

power

Input Running Current

W A dB(A) m3/min m3/min ,mm ,mm ,mm kg kg mm mm kg kg mm mm l/h / mm

power

Input Running Current

W A dB(A) m3/min m3/min ,mm ,mm ,mm kg kg mm mm kg kg mm mm l/h / mm

Indoor Units

0.36 45 / 38 Turbo Fan 26.5 32.0 R410A EEV 9.52 15.88 VP25 (OD 32,ID 25) 29.0 35.0 840x298x840 926x360x926 P4SMA 7.0 10.3 950x35x950 1,042x103x1,042 Filter / Safety Grille 24/750

Sound Fan Airflow Rate

Sound Pressure (High/Low) *4) Type Cooling (High) Heating (High)

Sound Fan Airflow Rate

Sound Pressure (High/Low) *4) Type Cooling (High) Heating (High)

Refrigerant

Type Control Method

Refrigerant

Type Control Method

Piping Connections

Liquid (Flare) Gas (Flare) Drain (Quick Lock)

Piping Connections

Liquid (Flare) Gas (Flare) Drain (Quick Lock)

Weight

Net Weight Shipping Weight

Weight

Net Weight Shipping Weight

Set Size

Net Dimensions (WxHxD) Shipping Dimensions (WxHxD)

Set Size

Net Dimensions (WxHxD) Shipping Dimensions (WxHxD)

Panel Size

Model Net Weight Shipping Weight Net Dimensions (WxHxD) Shipping Dimensions (WxHxD)

Panel Size

Model Net Weight Shipping Weight Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Filter / Safety Grille Drain Pump (Pumping speed / lift)

Standard Accessories
Notes

Filter / Safety Grille Drain Pump (Pumping speed / lift)

Filter / Safety Grille Filter / Safety Grille 24/750 24/750

*1) Mode: HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on: Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on: Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications are subject to change without prior notice for product improvement.

*1) Mode: HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on: Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on: Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications are subject to change without prior notice for product improvement.

2008 SAMSUNG DVM Air Conditioners

Indoor Units

Indoor Units - Duct type

84

85

Clean Filter System


The anti-bacteria filter and the filter cleaning indicator provide you with cleaner, healthier air. You deserve to breathe fresh air everyday.

BACTERIA

Anti-bacteria Filter

Easy Filter Cleaning


After 1,000 hours of operation the filter clean indicator will inform you that the filter should be cleaned. The filter can be easily removed from the bottom, left, or right of the unit. (1,000 hours is the default set time, which can be adjusted to 2,000 hours on the internal PCB.)

The anti-bacteria filter not only traps dust particles, but suppresses proliferation of molds and bacteria.

Indoor Units

HIGH

High Lift-up Drain Pump (optional)

The lift-up drain pump lifts condensed water up to 750mm, compared to the competitors 700mm, allowing for flexible and convenient installation.

Duct type Air conditioners


Samsung's new duct type air conditioners offer flexible installation benefits with its slim, compact size and the option to set up the air inlet either on the bottom or rear of the unit. Its Smart Pressure Control System also provides consistent cool and warm air regardless of the surrounding environment, and the filtering options give you cleaner, healthier air. Enjoy more with Samsung.

Air volume

Smart Pressure Control


The Smart Pressure Control System adjusts fan speed according to E.S.P(External Static Pressure), so the air conditioner always gives you consistent cooling and heating power regardless of the surrounding environment.

E.S.P Control
H M L H M L

Air volume 1mmAq

Air volume 3mmAq

Minimum

Maximum Static pressure (mmAq)

Duct type Icon


BACTERIA

ANTI-BACTERIA FILTER HIGH LIFT-UP DRAIN PUMP

EASY FILTER CLEANING

HIGH

SMART PRESSURE CONTROL

2008 SAMSUNG DVM Air Conditioners

Indoor Units

Indoor Units - Duct type

86

87

Slim and Flexible

Slim Duct

Optional Accessories

Individual Controllers
MWR-TH01 MWR-WS00 MWR-SH00 MR-BH01 MR-AH01

Drain Pump

MDP-E075SEE / MDP-E075SEE1

Specification |
Model Power Source Mode *1) Performance Capacity

Slim Duct type


AVXDSH022EE /V/Hz 1/220~240/50 HP/HR AVXDSH028EE 1/220~240/50 HP/HR 2.8 9,500 3.2 10,900 80 0.40 32 / 27 Sirocco Fan 9.0 10.0 2 (0~4) R410A EEV 6.35 12.70 VP25 (OD 32,ID 25) 26.0 31.0 900x199x600 1,133x333x722 Filter (Washable) AVXDSH036EE 1/220~240/50 HP/HR 3.6 12,200 4.0

Cooling *

2)

kW Btu/h

2.2 7,500 2.5 8,500 80 0.40 31 / 26 Sirocco Fan 8.0 9.0 2 (0~4) R410A EEV 6.35 12.70 VP25 (OD 32,ID 25) 26.0 31.0 900x199x600 1,133x333x722 Filter (Washable)

Heating *3)

kW Btu/h

Indoor Units

13,600 80 0.40 32 / 27 Sirocco Fan 10.0 12.0 2 (0~4) R410A EEV 6.35 12.70 VP25 (OD 32,ID 25) 26.0 31.0 900x199x600 1,133x333x722 Filter (Washable)

power

Input Running Current

W A dB(A) m3/min m3/min Standard(Min.~Max.) mmAq ,mm ,mm ,mm kg kg mm mm -

Sound Fan Airflow Rate

Sound Pressure (High/Low) *4) Type Cooling (High) Heating (High) External Static Pressure

Refrigerant
BACTERIA

Type Control Method

ANTI-BACTERIA FILTER

EASY FILTER CLEANING

HIGH

HIGH LIFT-UP DRAIN PUMP

SMART PRESSURE CONTROL

Piping Connections

Liquid (Flare) Gas (Flare) Drain

Flexible Installation
The air inlet can be set up on either the bottom or rear of the unit, so there is more flexibility in installation.
Tex

Rear side air inlet

Bottom side air inlet

Weight

Net Weight Shipping Weight

Set Size
Diffuser

Net Dimensions (WxHxD) Shipping Dimensions (WxHxD)

Tex Suction Duct

Diffuser

Suction Duct

Standard Accessories Optional Accessories

Filter / Safety Grille

Duct Receiver Kits Receiver Receiver Wire Drain Pump

MRK-A00 MRW-10A MDP-E075SEE

MRK-A00 MRW-10A MDP-E075SEE

MRK-A00 MRW-10A MDP-E075SEE

Notes

Slim Design
Only 199mm thick, this slim design makes installation, maintenance, and repair easy.

Easy to Maintain
Parts are easily accessible by simply opening the bottom panel, which reduces time and maintenance costs.

*1) Mode: HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on: Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on: Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications are subject to change without prior notice for product improvement.

199mm

199mm
220mm

225mm 160 180 200 210 220 230

2008 SAMSUNG DVM Air Conditioners

Indoor Units

Indoor Units - Duct type

88

89

Specification |
Model Power Source Mode *1) Performance Capacity

Slim Duct type


AVXDSH045EE /V/Hz 1/220~240/50 HP/HR AVXDSH056EE 1/220~240/50 HP/HR 5.6 19,100 6.3 21,400 100 0.60 33 / 30 Sirocco Fan 15.5 18.0 2 (0~4) R410A EEV 6.35 12.70 VP25 (OD 32,ID 25) 31.0 39.0 1,100x199x600 1,330x330x730 Filter (Washable) AVXDSH071EE 1/220~240/50 HP/HR 7.1 24,200 8.0 27,200 120 0.60 36 / 32 Sirocco Fan 16.5 20.0 2 (0~4) R410A EEV 9.52 15.88 VP25 (OD 32,ID 25) 31.0 39.0 1,100x199x600 1,330x330x730 Filter (Washable) Standard Accessories Set Size Weight Piping Connections Refrigerant Sound Fan Airflow Rate power Input Running Current Sound Pressure (High/Low) *4) Type Cooling (High) Heating (High) External Static Pressure Type Control Method Liquid (Flare) Gas (Flare) Drain Net Weight Shipping Weight Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Filter / Safety Grille Heating *3) Power Source Mode *1) Performance Capacity Cooling *
2)

Model /V/Hz

AVXDSH090EE 1/220~240/50 HP/HR kW Btu/h kW Btu/h W A dB(A) m3/min m3/min Standard(Min.~Max.) mmAq ,mm ,mm ,mm kg kg mm mm 9.0 30,700 10.0 34,100 170 0.96 40 / 36 Sirocco Fan 29.0 34.0 3 (0-6) R410A EEV 9.52 15.88

AVXDSH112EE 1/220~240/50 HP/HR 11.2 38,200 12.5 42,600 170 0.96 40 / 36 Sirocco Fan 31.2 34.0 3 (0~6) R410A EEV 9.52 15.88

AVXDSH128EE 1/220~240/50 HP/HR 12.8 43,600 13.8 47,000 200 1.13 41 / 38 Sirocco Fan 34.0 36.0 3 (0~6) R410A EEV 9.52 15.88

AVXDSH140EE 1/220~240/50 HP/HR 14.0 47,700 16.0

Cooling *

2)

kW Btu/h

4.5 15,300 5.0 17,000 90 0.60 33 / 30 Sirocco Fan 14.5 16.5 2 (0~4) R410A EEV 6.35 12.70 VP25 (OD 32,ID 25) 31.0 39.0 1,100x199x600 1,330x330x730 Filter (Washable)

Heating *3)

kW Btu/h

Indoor Units

54,500 220 1.24 41 / 38 Sirocco Fan 36.0 38.0 3 (0~6) R410A EEV 9.52 15.88

power

Input Running Current

W A dB(A) m3/min m3/min Standard(Min.~Max.) mmAq ,mm ,mm ,mm kg kg mm mm -

Sound Fan Airflow Rate

Sound Pressure (High/Low) *4) Type Cooling (High) Heating (High) External Static Pressure

Refrigerant

Type Control Method

Piping Connections

Liquid (Flare) Gas (Flare) Drain

VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) 43.0 51.5 1,300x295x690 1,600x444x831 Filter (Washable) 43.0 51.5 1,300x295x690 1,600x444x831 Filter (Washable) 46.0 54.5 1,300x295x690 1,600x444x831 Filter (Washable) 46.0 54.5 1,300x295x690 1,600x444x831 Filter (Washable)

Weight

Net Weight Shipping Weight

Set Size

Net Dimensions (WxHxD) Shipping Dimensions (WxHxD)

Standard Accessories Optional Accessories

Filter / Safety Grille

Duct Receiver Kits Receiver Receiver Wire Drain Pump

MRK-A00 MRW-10A MDP-E075SEE

MRK-A00 MRW-10A MDP-E075SEE

MRK-A00 MRW-10A MDP-E075SEE

Optional Accessories

Duct Receiver Kits Receiver Receiver Wire Drain Pump

MRK-A00 MRW-10A MDP-E075SEE1

MRK-A00 MRW-10A MDP-E075SEE1

MRK-A00 MRW-10A MDP-E075SEE1

MRK-A00 MRW-10A MDP-E075SEE1

Notes

Notes

*1) Mode: HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on: Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on: Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications are subject to change without prior notice for product improvement.

*1) Mode: HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on: Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on: Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications are subject to change without prior notice for product improvement.

2008 SAMSUNG DVM Air Conditioners

Indoor Units

Indoor Units - Duct type

90

91

Flexible and Silent

MSP Duct

Optional Accessories

Individual Controllers

Drain Pump

MWR-TH01

MWR-WS00

MWR-SH00

MR-BH01

MR-AH01

MDP-M075SGU1 / MDP-M075SGU2 / MDP-M075SGU3

Specification |
Model Power Source Mode *1) Performance Capacity

MSP Duct type


AVXDUH056EE AVXDUH071EE /V/Hz AVXDUH090EE AVXDUH112EE AVXDUH128EE AVXDUH140EE

1/220~240/50 1/220~240/50 1/220~240/50 1/220~240/50 1/220~240/50 1/220~240/50 HP/HR HP/HR 7.1 24,200 8.0 27,200 240*5) 1.2*
5)

HP/HR 9.0 30,700 10.0 34,100 240*5) 1.2*5) 39 / 35 Sirocco Fan 19.5 21.5 6 (4~8) R410A EEV 9.52 15.88 VP25 (OD 32,ID 25) 35.0 41.0

HP/HR 11.2 38,200 12.5 42,600 260 1.17 39 / 35 Sirocco Fan 27.0 27.0 8 (6~10) R410A EEV 9.52 15.88 VP25 (OD 32,ID 25) 39.0 46.0

HP/HR 12.8 43,600 13.8 47,000 370 1.67 39 / 35 Sirocco Fan 32.0 31.0 8 (6~10) R410A EEV 9.52 15.88 VP25 (OD 32,ID 25) 52.0 60.0

HP/HR 14.0 47,700 16.0

Cooling *

2)

kW Btu/h

5.6 19,100 6.3 21,400 240*5) 1.2*


5)

Heating *3)

kW Btu/h

Indoor Units

54,500 410 1.86 43 / 38 Sirocco Fan 37.0 36.0 8 (6~10) R410A EEV 9.52 15.88 VP25 (OD 32,ID 25) 52.0 60.0

power

Input Running Current

W A dB(A) m3/min m3/min Standard(Min.~Max.) mmAq ,mm ,mm ,mm kg kg mm mm -

Sound Fan Airflow Rate

Sound Pressure (High/Low) *4) Type Cooling (High) Heating (High) External Static Pressure

39 / 35 Sirocco Fan 14.5 15.5 4 (0~6) R410A EEV 6.35 12.70 VP25 (OD 32,ID 25) 31.0 36.0 900x260x480

39 / 35 Sirocco Fan 18.5 20.0 4 (0~6) R410A EEV 9.52 15.88 VP25 (OD 32,ID 25) 31.0 36.0 900x260x480

Refrigerant
BACTERIA

Type Control Method

ANTI-BACTERIA FILTER

EASY FILTER CLEANING

HIGH

HIGH LIFT-UP DRAIN PUMP

SMART PRESSURE CONTROL

Wired

WIRED REMOTE CONTROLLER

Piping Connections

Liquid (Flare) Gas (Flare) Drain

Weight

Net Weight Shipping Weight

Silent Operation with the static pressure control


The external static pressure control makes it easy to design duct work to ensure efficiency and silent operation.
Set Size Standard

Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Filter / Safety Grille

1,150x260x480 1,150x320x480 1,200x360x650 1,200x360x650

1,146x345x584 1,146x345x584 1,390x345x584 1,390x420x584 1,447x425x769 1,447x425x769 Filter (Washable) Filter (Washable) MRK-A00 MRW-10A Filter (Washable) MRK-A00 MRW-10A Filter (Washable) MRK-A00 MRW-10A Filter (Washable) MRK-A00 MRW-10A Filter (Washable) MRK-A00 MRW-10A

Narrow Width (5.6kW)

Middle Static Pressure


10 8 6 0~10mmAq 4 2 0~6mmAq

Accessories Optional Accessories Drain Pump


Notes

Duct Receiver Kits Receiver Receiver Wire

MRK-A00 MRW-10A

MDP-M075SGU3 MDP-M075SGU3

MDP-M075SGU1 MDP-M075SGU1

MDP-M075SGU2 MDP-M075SGU2

900mm
Width measured without control box.

mmAq

Slim Duct

MSP Duct

Easy to Maintain
Reduce time and maintenance costs by keeping parts easily accessible.

Flexible Installation
Samsung's MSP Duct air conditioners offer different solutions for any shape room allowing for specific airflow requirements.

*1) Mode: HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on: Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on: Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications are subject to change without prior notice for product improvement.

L-shaped area

Areas far apart

Y-shaped area

2008 SAMSUNG DVM Air Conditioners

Indoor Units

Indoor Units - Floor & Convertible type

92

93

Floor & Convertible type Air conditioners


Samsung introduces a new elegance in air conditioners. This year's new console and ceiling type air conditioners have the style to complement any decor. The flexibility of drain pipe placement also gives you more options in where you want to place the air conditioner. Staying cool has never been more stylish.

INTERIOR DESIGN

Interior Design

Now with more flexibility in placement, the air conditioner can add a stylish element to your room.

Floor & Convertible type Icon


INTERIOR DESIGN

Indoor Units

INTERIOR DESIGN SILENT MODE

BACTERIA

ANTI-BACTERIA FILTER

LIGHT

LIGHT WEIGHT UNIT WIRELESS REMOTE CONTROL

Silent Mode
Indoor units operate quietly with the least possible noise.

BACTERIA

Anti-bacteria Filter

The anti-bacteria filter not only traps dust particles, but suppresses proliferation of molds and bacteria.

Flexible Pipe

Installation

FLEXIBLE PIPE INSTALLATION

Wireless

LIGHT

Light Weight Unit


This extremely lightweight design makes maintenance and installation easy.

Flexible Pipe

Installation

Flexible Pipe Installation

The drain pipe can be installed in 6 different places, so you have more options in where to place your air conditioner.

2008 SAMSUNG DVM Air Conditioners

Indoor Units

Indoor Units - Floor & Convertible type

94

95

Slim and Elegant

Console
Elegant Design
Slim & Smart Design
This extremely slim design with Clean Panel adds aesthetic value to any interior.

Slim Design Indoor Units


It can't get any slimmer. This newly introduced console type air conditioner is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your decor.

199mm

Clean Panel
Stay clean with the smartly designed Clean Panel. This unique panel keeps dust from being accumulated so the unit and the room stays cleaner.

Black Display
Functional art, the touch screen display is elegant while it maximizes the convenience of control.

2Way air outlets


There are two separate air outlets for cooling and heating. Having warmer air coming out from the bottom part of the air outlet will spread the warm air evenly throughout the room. Stay cooler and warmer in every corner of your room.
INTERIOR DESIGN

INTERIOR DESIGN

BACTERIA

ANTI-BACTERIA FILTER

LIGHT

LIGHT WEIGHT UNIT

SILENT MODE

Flexible Pipe

Installation

FLEXIBLE PIPE INSTALLATION

Wireless

WIRELESS REMOTE CONTROL

Silent Operation (23dB)

Optional Accessories

Individual Controllers

The silent, yet powerful and efficient cooling and heating system keeps things more comfortable. Silent mode is available in 4 different operating modes: High / Medium / Low / Silence.

MWR-TH01

MWR-WS00

MWR-SH00

ARH-1379

2008 SAMSUNG DVM Air Conditioners

Indoor Units

Indoor Units - Floor & Convertible type

96

97

Specification |
Model Power Source Mode *
1)

Console
AVXTJH028EE /V/Hz 1/220~240/50 HP/HR Power Source Mode *
1)

Model /V/Hz

AVXTJH036EE 1/220~240/50 HP/HR

Performance

Capacity

Cooling *

2)

kW Btu/h

2.8 9,500 3.2 10,900 30 0.25 38 / 23 *


5)

Performance

Capacity

Cooling *

2)

kW Btu/h

3.6 12,200

Indoor Units

Heating *

3)

kW Btu/h

Heating *

3)

kW Btu/h

4.0 13,600 35 0.29 39 / 24 *5) Turbo Fan 8.7*5) 8.9*5) R410a EEV 6.35 12.70 ID 18 hose 15.0 19.0 720x620x199 810x710x295 Filter (Washable) ARH-1379

power

Input Running Current

W A
4)

power

Input Running Current

W A
4)

Sound Fan Airflow Rate

Sound Pressure (High/Low) * Type Cooling (High) Heating (High)

dB(A) m3/min m3/min ,mm ,mm ,mm kg kg mm mm -

Sound Fan Airflow Rate

Sound Pressure (High/Low) * Type Cooling (High) Heating (High)

dB(A) m3/min m3/min ,mm ,mm ,mm kg kg mm mm -

Turbo Fan 7.8*


5)

7.2*5) R410a EEV 6.35 12.70 ID 18 hose 15.0 19.0 720x620x199 810x710x295 Filter (Washable) AHR-1379 Standard Accessories Set Size Weight Piping Connections Refrigerant

Refrigerant

Type Control Method

Type Control Method Liquid (Flare) Gas (Flare) Drain (Quick Lock) Net Weight Shipping Weight Net Dimensions (WxHxD) Shipping Dimensions (WxHxD) Filter / Safety Grille Wireless Remote Controller

Piping Connections

Liquid (Flare) Gas (Flare) Drain (Quick Lock)

Weight

Net Weight Shipping Weight

Set Size

Net Dimensions (WxHxD) Shipping Dimensions (WxHxD)

Standard Accessories

Filter / Safety Grille Wireless Remote Controller

Notes

Notes

*1) Mode: HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on: Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on: Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications are subject to change without prior notice for product improvement.

*1) Mode: HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on: Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on: Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications are subject to change without prior notice for product improvement.

2008 SAMSUNG DVM Air Conditioners

Indoor Units

Indoor Units - Floor & Convertible type

98

99

Slim and Compact

Optional Accessories

Individual Controllers

Ceiling
Specification |
Model Power Source Mode *
1)

MWR-TH01

MWR-WS00

MWR-SH00

MR-BH01

MR-AH01

Ceiling
AVXTFH056EE /V/Hz 1/220~240/50 HP/HR AVXTFH071EE 1/220~240/50 HP/HR 7.1 24,200

Performance

Capacity

Cooling *

2)

kW Btu/h

5.6 19,100 6.3 21,400 72 0.33 38 / 32 Sirocco Fan 14.0 14.5 R410a EEV *
6)

Indoor Units

Heating *

3)

kW Btu/h

8.0 27,200 80 0.35 41 / 36 Sirocco Fan 18.0 18.5 R410a EEV *6) 9.52 15.88 ID 18 hose 22.0 26.0 1,000x650x200 1,074x726x294 Filter (Washable) -

power

Input Running Current

W A
4)

Sound Fan Airflow Rate

Sound Pressure (High/Low) * Type Cooling (High) Heating (High)

dB(A) m3/min m3/min ,mm ,mm ,mm kg kg mm mm -

Refrigerant

Type Control Method

Piping Connections
INTERIOR DESIGN ANTI-BACTERIA FILTER
LIGHT

Liquid (Flare) Gas (Flare) Drain (Quick Lock)

6.35 12.70 ID 18 hose 22.0 26.0 1,000x650x200 1,074x726x294 Filter (Washable) -

INTERIOR DESIGN

BACTERIA

LIGHT WEIGHT UNIT

Flexible Pipe

Installation

FLEXIBLE PIPE INSTALLATION

Weight

Net Weight Shipping Weight

Set Size

Net Dimensions (WxHxD) Shipping Dimensions (WxHxD)

Standard

Filter / Safety Grille Wireless Remote Controller

2way Installation
Depending on the space availability and the purpose of the air conditioner, the indoor unit can be installed under the ceiling or on the floor.

Accessories

Notes

Under Ceiling

Floor Standing

*1) Mode: HP: Heat Pump, HR: Heat Recovery *2) Nominal cooling capacities are based on: Indoor temperature: 27C DB, 19C WB, Outdoor temperature: 35C DB, 24C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *3) Nominal heating capacities are based on: Indoor temperature: 20C DB, 15C WB, Outdoor temperature: 7C DB, 6C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications are subject to change without prior notice for product improvement. *6) Optional Accessory.

Compact but Powerful


Samsungs ceiling type air conditioner boasts a slim, compact design, half the size of its competitors, with cooling power comparable to competitors larger products.

7.1kW Model Size


100% 118% 200%

Weight
Smaller
100% 123% 136%

Lighter

2008 SAMSUNG DVM Air Conditioners

Indoor Units

Indoor Units - ERV System

100

101

How it Works
Outdoor Indoor

Winter
It reduces the costs of heating ventilated air by transferring heat from the warm inside air being exhausted to the fresh (but cold) supply air.

Cool

Cool

Element
Heat Cool Heat Cool Heat Heat

Heat

Summer
The inside air cools the warmer supply air to reduce ventilation cooling costs.
Cool

Cool

Cool

Heat

Indoor Units Indoor Units

Key Technology
New Diamond Type
q Optimized q High

Rectangular Type

Hexagonal Type

Airflow Design

Efficiency Element size

q Compact

Diamond Type

Automatic Refresh System (CO2 Sensor) : Optional

ERV System
Energy Recovery Ventilator
Samsungs ERV System has applied the cross flow ventilating method which assure you efficient ventilation and energy saving. Furthermore, ERV System has adopted total heat exchange (sensible heat + latent heat) as a heat recovery process that helps maintaining indoor temperature and humidity and minimizing indoor heat loss caused by ventilation
2008 SAMSUNG DVM Air Conditioners

q ERV

is automatically operated to give fresh air into room by sensing CO2 Level.

High Efficiency Motor (BLDC)


q Constant

air volume by BLDC motor.

Intelligent Operating System (-15C) Without Heater

Indoor Units

Indoor Units - ERV System

102

103

Line-up
Compact Size & Flexible Installation
q Compact

RHF025EE
250

RHF035EE
350

RHF050EE
500

RHF080EE
800

RHF100EE
1,000

and Slim in Size by High Efficiency Diamond Element.

Ex.) Model No. RHF-035~050

Specification |
Model Voltage Frequency Withstand Voltage Insulation Resistance Air Volume External Static Pressure Leakage Rate Power Input Current Temperature Exchange Cooling Heating Cooling Heating V Hz -

ERV System
Indoor Units Indoor Units
RHF025EE 220~240 50/60 AC1500V, 1min 30MG 250 110 10 115 0.7 70 70 50 70 38 RHF035EE 220~240 50/60 AC1500V, 1min 30MG 350 155 10 115 0.7 70 70 50 70 40 RHF050EE 220~240 50/60 AC1500V, 1min 30MG 500 165 10 175 1.1 70 70 50 70 42 RHF080EE 220~240 50/60 AC1500V, 1min 30MG 800 155 10 RHF100EE 220~240 50/60

AC1500V, 1min 30MG 1,000 155 10 450 2.9 70 70 50 70 48 High efficiency filter(PP) 1,220X340X1,135

m3/hr Pa % W A % % % % dB(A) WxHxD WxHxD mm mm kg ,mm

330 2.1 70 70 50 70 46 High efficiency filter(PP) 1,220X340X1,135

Energy Saving Operation (Auto Mode)


It automatically changes operation mode depending on temperature difference between indoor and outdoor to save energy.
Damper

Efficiency Effective Enthalpy Exchange Efficiency Sound Level

Extreme Climates (Winter & Summer)


When temperature and humidity level difference between indoor and outdoor is big, it operates as ERV.

EA Element OA

RA Dust Collection Method Dimensions (Net) SA Dimensions (Gross) Weight (Net/Gross) Damper 760X400X807 25.5/30 150 1,299X337X1,183 1,299X337X1,183 42.5/53.5 200 42.5/53.5 200 1,475X 440 X1,330 1,475X440X1,330 67/75.5 250 67/75.5 250 High efficiency filter(PP) High efficiency filter(PP) High efficiency filter(PP) 600X350X660 1,012X270X1,000 1,012X270X1,000

Mild Climates (Spring & Fall)


When temperature and humidity level difference between indoor and outdoor is small, it operates as conventional ventilation fan.

Duct Diameter RA

EA Element OA

SA

2008 SAMSUNG DVM Air Conditioners

Indoor Units

Indoor Units - Accessories

104

105

Accessories
Indoor Units
Classification Feature Model
MXJ-YA1509K MXJ-YA2512K MXJ-YA2812K Y-Joint MXJ-YA2815K MXJ-YA3119K MXJ-YA3819K MXJ-YA4422K MXJ-HA2512K Header Joint MXJ-HA3115K MXJ-HA3819K Y-Joint (Only for DVM PLUS III HR in high pressure gas connection) MXJ-YA1500K MXJ-YA2500K MXJ-YA3100K MXJ-YA3800K Outdoor Joint for DVM PLUS III / HR (Outdoor Connection) Outdoor Joint only for DVM PLUS III HR Module (High Pressure Gas Connection) MXJ-T3819K MXJ-T4422K MXJ-T3100K MXJ-T3800K MCU-4EAE1 MCU Kits MCU-4EAEV1 MCU-6EAE1
Notes

Description
15.0kW and below Over 15.0 ~ 40.6kW and below Over 40.6 ~ 46.4kW and below Over 46.4 ~ 69.6kW and below Over 69.6 ~ 98.6kW and below Over 98.6 ~ 139.2kW and below

Relevant Unit

Remark

Classification
EEV Kits

Feature

Model
MXD-A13K116A

Description
Below 3.6kW (1 Room) + 5.6 kW~9.0kW (1Room)

Relevant Unit

Remark

DVM DVM DVM DVM

PLUS PLUS PLUS PLUS

II, II HR III, III HR

MXD-A13K200A Requisite MXD-A16K200A MXD-A22K200A MXD-A13K216A

Below 3.6kW (2 Rooms) 5.6 kW~9.0kW (2Rooms) 5.6 kW~7.1kW (2Rooms) Below 3.6kW (2 Rooms) + 5.6 kW~9.0kW (1Room)

Wall-mounted & Ceiling indoor unit (For 2 indoor units)

Option

Over 139.2kW MXD-A13K300A Below 46.4kW 46.5 ~ 69.6kW Over 69.7kW 23.2kW and below Over 23.2 ~ 63.9kW and below DVM PLUS III HR Over 69.6 ~ 139.2kW and below Over 139.3kW Below 48HP Over 50HP Below 48HP Over 50HP Below 4 indoor units Below 4 indoor units *1) Below 6 indoor units P4SMA 4 Way Cassette DVM PLUS II HR, DVM PLUS III HR Requisite (HR only) P2SMA 2 Way Cassette Requisite DVM PLUS II, DVM PLUS II HR, DVM PLUS III, DVM Requisite PLUS III HR (Module) DVM PLUS III HR (Module) Requisite Drain Pump DVM DVM DVM DVM PLUS PLUS PLUS PLUS II, II HR III, III HR MXD-A16K213A Option MXD-A16K300A MEV-A13SA MEV-A16SA MDP-E075SEE MDP-E075SEE1 MDP-M075SGU1 MDP-M075SGU2 MDP-M075SGU3 Requisite Front Panel PSSMA Slim 1 Way Cassette Below 3.6kW (3 Rooms) Below 3.6kW (1 Room) + 5.6 kW~9.0kW (2Rooms) 5.6 kW~9.0kW (3Rooms) Below 3.6kW (1 Room) 5.6 kW~9.0kW (1Room) Slim Duct (2.2~7.1) kW Slim Duct (9.0~14.0) kW M.S.P Duct (9.0, 11.2) kW M.S.P Duct (12.8, 14.0) kW M.S.P Duct (5.6, 7.1) kW Option Wall-mounted & Ceiling indoor unit (For single unit) Wall-mounted & Ceiling indoor unit (For 3 indoor units) Option

Option

*1) MCU-4EAEV1 is the product that includes built in EEV to connect the indoor unit (wall-mounted type and ceiling type) that does not include EEV. PMSMA Mini 4 Way Cassette

2008 SAMSUNG DVM Air Conditioners

Indoor Units

Control Systems

106

107

Control Systems

imagine
the complete control
Effective and complete control systems are here. Samsungs control systems are easy to control, simple and user-friendly. These effective and convenient control systems will not only control but also monitors, manages and maintain all the information of your air conditioner. Complete control, in your hands.

Control Systems

>> 108_ Integrated Management System >> 116_ Centralized Control System >> 118_ Individual Control System >> 120_ Building Management System >> 123_ Accessories

Control Systems - Integrated Management System

108

109

Building Management System Easy Control & Monitoring

Power Distribution System

DMS
Web Server Function

Schedule Control Function

Integrated Management System


Samsungs Integrated Management System provides the easiest and most convenient way to manage a large number of air conditioning units at once. This Integrated Management System will help you control, monitor, manage and maintain every little detail of your air conditioning needs.

Data Management Server


Samsung's Data Management Server (DMS) lets you monitor and control your on-site air conditioning needs remotely. It's the easiest and most convenient way to manage a large number of air conditioning units at once.

Control Systems

MIM-D00
Built-in web server for PC-independent management and remote access control Multiple upper-layer control access (S-NET 3, S-NET Mini, Web-client) Individual/Group control of up to 256 indoor units and heat exchange units Error history management Weekly/Daily schedule control Power distribution function 2 digital inputs, 2 digital outputs Current time management even during power failure (for 24 hours) Data storage in non-volatile memory Emergency stop function with simple contact interface

2008 SAMSUNG DVM Air Conditioners

Control Systems

Control Systems - Integrated Management System

110

111

DMS System Schedule Control Function


Centralized Controller Interface Module

08:00 AM On

10:00 PM Off

Up to 256 schedule settings. Weekly, Daily or 1-Day schedule control. Exception date setting.

Cooling Schedule Setup

DMS

Interface Module Centralized Controller

History Management
Easy service and management with error history. Occurrence date, error details, current state.
Interface Module

Rapid Service Response

Service

Control Systems

Error History Monitoring

SIM

Watt Hour Meter

Power Distribution System


Power distribution to up to 256 indoor units. Data query for watt-hour, use time and use ratio. File save in Microsoft Excel format. 93 days worth of power distribution data storage.
140 kWh

Main Features
Easy Control & Monitoring
Individual/Group control and monitoring up to 256 indoor units. Operation mode, temperature setting, airflow direction and fan speed. Wireless/wired remote control restriction. Easy multiple/full indoor unit selection. Full room temperature display. Error history query based on date.

610 kWh

460 kWh

360 kWh 180 kWh

External Contact Interface

Web Server Function


Built-in web server. Multiple upper-layer control access with prioritized management. Remote access control with the static IP address.

Full indoor unit control with simple contact input. (Emergency/Lock) State output (Operation/Error) for synchronous control.

Building Control System

Operation Restriction

Internet
Anytime, Anywhere Control

Fire Control System

Error Status Indicator

2008 SAMSUNG DVM Air Conditioners

Control Systems

Control Systems - Integrated Management System

112

113

Main Features
Control and Monitoring
Control & monitoring of up to 4,096 indoor units Heat exchange unit management Wireless/wired remote control restriction Temperature limit setting Multiple/full indoor unit selection Icon-based indoor unit display mode

Schedule Control
Graphical schedule settings Weekly, Daily schedule control Exception date setting

Smart Net Control System


Zone Management
S-NET is a complex management program that controls and monitors a complete air conditioner network system. The S-NET series provides flexible and complete control for a variety of applications.
Management structure customization regardless of installation structure Control zone creation/edition/deletion Tree structure zone management control

Control Systems

S-NET 3
Fully integrated PC management software. Up to 16 DMSs connection through the Ethernet. Centralized management up to 4,096 indoor/heat exchange units. Schedule/Zone control. Error/Operation history management. Power distribution management and analysis. Automatic update through the Internet.

Power Distribution Management


Data query for power distribution and operation time Power distribution report generation and print Time section setting for different electricity rates Group setting for power distribution summation

History Management
Error/Event history management Indoor unit operation history management Report generation and print

16 DMSs

Supports

Cycle monitoring
S-NET 3
Monitoring outdoor / indoor unit cycle data (Supported for specific outdoor unit models)

Max. 16 units

2008 SAMSUNG DVM Air Conditioners

Control Systems

Control Systems - Integrated Management System

114

115

S-NET mini
Dynamic compatibility options (DMS, centralized controller, interface module) Control and monitoring of up to 256 indoor units Detailed cycling information monitoring Schedule function (Weekly, Daily) USB keyboard supported Error display 7-inch wide LCD restriction Temperature limit setting Touch screen Zone control Child-lock setting

Main Features
Control and monitoring
Control & Monitor up to 256 indoor units Operation control and monitoring Detailed operation cycling information monitoring Wireless/wired remote control restriction setting

Schedule Control
Maximum 256 Weekly, Daily schedule control Schedule repetition, exception date setting Schedule edit (add, edit, delete) Detailed operation schedule setting Remote control restriction option setting

Control Systems

Zone Management
Management structure customization regardless of installation structure Control zone creation/edition/deletion

Dynamic Compatibility Option Temperature Limit Setting


4 DMSs

Supports

Upper/Lower temperature limit setting

Supports
16 Centralized Controllers

Cycle Monitoring
w

Outdoor/Indoor unit cycling information monitoring (supported for specific outdoor unit models)

Supports
16 Interface Modules

Error Management
Error history management Error management information query Detailed error information query

2008 SAMSUNG DVM Air Conditioners

Control Systems

Control Systems - Centralized Control System

116

117

Centralized Controller
MCM-A202A

Function Controller
MCM-A100
Operation Error Error Filter

Maximum 16 group controls (Maximum 256 Indoor units) Unified/Individual indoor unit control (On/Off) Wireless/wired remote control restriction Cooling/Heating mode control Indoor unit error display

Control and monitoring of up to 16 indoor unit groups


To use Function Controller, it requires to be connected to MCM-A202A

Centralized Control System


Samsung's advanced technology has come up with the centralized control that is convenient and efficient. Samsung's centralized control system can control and monitor 4,096 individual indoor units and 256 groups of indoor units simultaneously.

Operation Mode Selection Switch


MCM-C200

Interface Module
MIM-B13A

Control Systems

MIM-B04A

Operation mode selection (Cooling, Heating or Auto) Mixed operation mode protection Communicator between indoor/outdoor units and the centralized controller

S-NET II Plus
Indoor unit control of up to 256 groups Extensive individual control of up to 4096 indoor units Weekly and Daily schedule function Zone setting and control Dynamic exchange to Permitted and Prohibited wireless/wired remote control Full/Group/Individual indoor unit display

256 group 4096 indoor units controls

Individual control

Schedule control

Zone control

Function Icon
Operation

ON/OFF, OPERATION MODE, FAN SPEED, AIRFLOW, TEMPERATURE SETTING

Group

INDIVIDUAL AND GROUP CONTROL (MAXIMUM 16 INDOOR UNITS)


S-NET II Plus

RS232-RS485 Converter

Error Error

Filter

ERROR DISPLAY

FILTER REPLACEMENT ALARM RESET


Max. 16 units

2008 SAMSUNG DVM Air Conditioners

Control Systems

Control Systems - Building Management System

120

121

Building Management System


BMS (Building Management System) makes it possible to control and monitor the air conditioning network using the remote control and monitoring function. Optimum control keeps the air conditioning system efficient, saves energy, reduces maintenance costs, and extends the life cycle of the units.

MIM-B07
Interface for Lon-Connection to Lonworks management system Quick and easy installation Up to 12 indoor units can be controlled Communication : 485 to Lonworks Upper physical layer : FTT-10A BMS Control Function
On/Off control Temperature setting Operation mode Fan speed

Monitoring Function
On/Off Operation mode Room temperature Error information

Guest Room Management System


The Guest Room Management System is a smart way to save energy and money. When the Key Tag is in place, the air conditioner is activated. When the Key Tag is removed, the air conditioner turns off. Now you can avoid cooling an unoccupied room and save energy.
ON

Control Systems

OFF

MIM-B02
Indoor unit control by external contact signals Individual/Group control of up to 16 indoor units Combinational use with sensor/timer/emergency inputs

Room 501

Room 502

Room 503

Room 504

KeyHolder

KeyHolder

KeyHolder

KeyHolder

External Contact Interface Module


MIM-B14
Direct indoor unit control by external contact signal Window-synchronized indoor unit control Emergency control with simple contact input Indoor unit operation/error state output through relay contacts

2008 SAMSUNG DVM Air Conditioners

Control Systems

Control Systems - Individual Control System

118

119

Individual Control System


There are many ways to control your air conditioner, but one smart controller is all you need. Samsung provides several different control options that can control one indoor unit to a group of indoor units with one system.

Wired Remote Controller


MWR-WS00 (Premium)
Operation Group Error Error Filter

MWR-TH01
Operation Group Error Error Filter

Weekly schedule setting (Maximum 70 schedules) Exception date setting Built-in room temperature sensor Clear and bright screen with LCD backlight Temperature limit setting Wireless remote control restriction Automatic Stop mode Sleep and Silent mode Child lock

Simple schedule control Wireless remote control restriction

Control Systems

Simplified wired remote controller


MWR-SH00
Operation Group Error Error Filter

ERV Wired remote controller


MWR-VH01
Individual and group control (Maximum 16 ERVs) On/Off control Operation mode (By-Pass, Heat Exchange), fan speed Simple schedule control Error display Synchronous operation with indoor units

Mode selection protection

Function Icon
Operation

ON/OFF, OPERATION MODE, FAN SPEED, AIRFLOW, TEMPERATURE SETTING

Group

INDIVIDUAL AND GROUP CONTROL (MAXIMUM 16 INDOOR UNITS)

Wireless Signal Receiver


(for Duct-type indoor unit) MRK-A00

Filter

7-day Scheduler
MWR-BS00
Up to 100 weekly and daily schedule settings Schedule setting based on 1-minute time units Digital clock display Permanent schedule setting storage Current time protection from blackout (maximum 3 days) Use with wired remote controller, or centralized controller. (MWR-TH01, MCM-A202A)

Error Error

Filter

ERROR DISPLAY

FILTER REPLACEMENT ALARM RESET

Wireless Remote Controller


MR-BH01
Operation Filter

MR-AH01
Operation

ON/OFF control Operation indication Error Indication Filter replacement sign Use with receiver wire, MRW-10A

Simple schedule control Wide display Soft touch button

Compact size Simple schedule control Soft touch button

2008 SAMSUNG DVM Air Conditioners

Control Systems

Control Systems - Building Management System

Accessories
Classification
Integrated Management System Controller

Power Distribution Unit


MCM-B102
Real-time power distribution for one indoor/outdoor system. Power distribution to maximum 48 indoor units. Communication error display. Total system power consumption display. Power consumption display of individual indoor units. Data storage even during a power failure.

Product
DMS

Model
MIM-D00

Image

Application Model
DVM Series, FJM, CAC, ERV

S-NET 3

MST-P3P

DVM Series, FJM, CAC, ERV

S-NET mini

MST-S3W

DVM Series, FJM, CAC

Interface Module

SiM

MIM-B12

DVM Series, FJM

Centralized Control System RS 485

Controller

S-NET II Plus

MSP-S1P

DVM, DVM HR, DVM PLUS II, DVM PLUS II HR, FJM, CAC DVM Series, FJM, CAC, ERV

Centralized Controller

MCM-A202A

Room01 (60kWh) Room02 (120kWh) Room04 (210kWh) RS 485 600kWh

Power Supply

Function Controller

MCM-A100

DVM Series, FJM, CAC

Room01 Room02 Room03 Room04


Interface Module

Operation Mode Selection Switch

MCM-C200

DVM Series Mini DVM(R410A), DVM PLUS II, DVM PLUS II HR, DVM PLUS III, DVM PLUS III HR, FJM, ERV DVM, DVM PLUS, DVM HR, CAC

Centralized Control Interface Module

MIM-B13A

Control Systems

MIM-B04A

Room03 (210kWh)

Individual Control System

Controller

Wireless Remote Controller

MR-AH01 MR-BH01 MWR-WS00

Cassette, Ceiling, Duct (Receiver needed), Console (Included) Cassette, Wall Mounted, Ceiling, Duct, Console Cassette, Wall Mounted, Ceiling, Duct, Console Cassette, Wall Mounted, Ceiling, Duct, Console ERV

Wired Remote Controller (Premium)


40% 35.0%35.3% 35.0%35.1%

30% 20% 19.4%

Wired Remote Controller

20% 10.2% 10.2%

10%

Room 01 electric power consumption


Actual Usage Rate Displayed Rate
Room03 Room04

Demand capacity of Room 01 Total demand capacity of indoor units

MWR-TH01

Total power consumption

Simplified Wired Remote Controller

MWR-SH00

0%

Room01

Room02

ERV Wired Remote Controller

MWR-VH01

Consult with Samsung Electronics for watt-hour meter interface


Wireless Signal Receiver Kit Wireless Signal Receiver MRK-A00 Duct (For Wireless Remote Controller)

Receiver Wire

MRW-10A

Duct (For Wireless Remote Controller)

7-day Scheduler

MWR-BS00

Cassette, Wall Mounted, Ceiling, Duct

Watt-hour meter Interface Module


MIM-B12
Exclusive use for DMS power distribution. Connection with up to 8 watt-hour meters. RS485 interface with watt-hour meters. Power consumption display for each watt-hour meter. Automatic detection of specified watt-hour meters.

Building Management System Guest Room Management System

Lonworks Interface Module

MIM-B07

DVM Series, FJM

Key-tag Interface Module

MIM-B02

DVM Series, FJM

External Contact Interface Module

MIM-B14

Mini DVM(R410A), DVM PLUS II, DVM PLUS II HR, DVM PLUS III, DVM PLUS III HR (Non RAC/Console) DVM Series, FJM

Power Distribution

Power Distribution Unit

MCM-B102

DVM Series : Mini DVM, DVM, DVM PLUS, DVM HR, DVM PLUS II, DVM PLUS II HR, DVM PLUS III, DVM PLUS III HR

2008 SAMSUNG DVM Air Conditioners

Control Systems

Você também pode gostar