Danfoss ERC213 Parameters Review
Danfoss ERC213 Parameters Review
ratings:
Length:
75 minutes
Released:
Jun 27, 2018
Format:
Podcast episode
Description
Danfoss ERC 213 Timestamps: 10:30 – Key Features 10:41 – Voltage Protection 10:56 – Compressor Protection 14:43 – Applications 15:15 – App 0 No predefined application 15:28 – App 1 Medium temperature ventilated refrigeration units with timed natural defrost 15:52 – App 2 Medium temperature ventilated refrigeration units with timed electrical defrost 16:03 – App 3 Low temperature ventilated refrigeration units with timed electrical defrost 16:13 – App 4 Medium temperature ventilated refrigeration units with electrical defrost (by temperature) 16:26 – App 5 Low temperature ventilated refrigeration units with electrical defrost (by temperature) 16:37 – App 6 No predefined application with simplified list of parameters 19:45 – Sensors 22:06 – Basic Groups of Parameters 23:09 – r-- Thermostat 23:12 – r00 Temperature setpoint 23:24 – r01 Differential 23:32 – r02 Min setpoint limitation and r03 Max setpoint limitation 24:02 – r04 Display offset 25:19 – r05 Display Unit (°C/°F) 25:33 – r09 Calibration of Sair 25:47 – r12 Main switch 27:17 – r13 Night set back 27:48 – r40 Thermostat reference displacement (offset temperature) 28:30 – r96 Pull-down duration and r97 Pull-down limit temperature 29:06 – A-- Alarms 29:13 – A03 Delay for temperature alarm during normal conditions 30:15 – A12 Delay for temperature alarm during pull-down/start-up/defrost 31:00 – A13 High temperature alarm limit (Cabinet/Room) 31:34 – A14 Low temperature alarm limit 31:55 – A27 DI1 delay and A28 DI2 delay 32:17 – A37 Condenser high alarm limit 32:41 – A54 Condenser high block limit 33:45 – A72 Voltage protection enable 34:03 – A73 Minimum cut-in voltage and A74 Minimum cut-out voltage 35:04 – A75 Maximum Voltage 37:37 – d-- Defrost 37:49 – d01 Defrost method 38:32 – d02 Defrost stop temperature 38:50 – d10 Defrost stop sensor 40:51 – d03 Defrost interval 41:16 – d04 Max defrost time 43:38 – d05 Defrost delay at power up (or DI signal) 44:29 – d06 Drip delay 44:49 – d07 Fan delay after defrost 45:49 – d08 Fan start temperature after defrost 47:21 – d09 Fan during defrost 47:40 – d10 Defrost stop sensor (part II) 48:16 – d18 Compressor accumulated runtime to start defrost 50:04 – d19 Defrost on demand 53:26 – d30 Defrost delay after pull-down 53:53 – F-- Fan control 54:03 – F01 Fan at compressor cutout 55:00 – F04 Fan stop evaporator temperature 55:51 – F07 Fan ON cycle and F08 Fan OFF cycle 56:28 – c-- Compressor 56:37 – c01 Compressor minimum ON time 56:47 – c02 Compressor minimum OFF time 57:01 – c04 Compressor OFF delay at door open 57:51 – c70 Zero crossing selection 58:22 – o-- Others 58:37 – o01 Delay of outputs at startup 59:11 – o02 DI1 configuration 1:01:36 – o05 Password 1:02:08 – o06 Sensor type selection 1:02:27 – 015 Display resolution 1:03:31 – o23 Relay 1 counter, o24 Relay 2 counter and 025 o24 Relay 3 counter 1:04:13 – o37 DI2 configuration 1:04:52 – o61 DI2 configuration 1:05:07 – o67 Save settings as factory 1:05:39 – o71 DO2 config 1:06:23 – o91 Display at defrost 1:07:04 – P-- Polarity 1:07:06 – P73 DI1 input polarity and P74 DI2 input polarity 1:07:32 – P75 Invert alarm relay 1:07:59 – P76 Keyboard lock enable 1:08:21 – u-- Readouts 1:08:30 – u00 Controller Status 1:09:37 – u01 Air temperature (Sair) 1:10:12 – u58 Compressor relay status, u59 Fan relay status, u60 Defrost relay status and u63 Light relay status
Released:
Jun 27, 2018
Format:
Podcast episode
Titles in the series (100)
Why a TXV instead of a TEV?.. or a CSV?: Bryan talks to Leslie about the mysterious and magical TXV valve.. What it is, what is does and why they get misdiagnosed so often. Thanks to Daniel Anderson for making this his first episode suggestion. by HVAC School - For Techs, By Techs