ISSUE 1.1
Lesson Goal
HUAWEI
Know about the hardware structure and logical structure of the SG7000
SG7000 boards
Lesson Contents
HUAWEI
Chapter 1 SG7000 Hardware Structure Chapter 2 SG7000 Logical Structure Chapter 3 SG7000 Message Flow
Section 1 Service Shelf Configuration Section 2 Board Introduction Section 3 Hardware Working Principle
Cabinet
HUAWEI
The
SG7000 uses IEC-standard B68-21 cabinet, with main control cabinet is configured with one BAM server,
two Ethernet LAN switches (for internal connection), one LCD display switcher and one or two service shelves.
2U
14U
1U 1U
Service shelf
14U
2U
Dummy panel LAN Switch 1 LAN Switch cabling frame LAN Switch 0 LAN Switch cabling frame BAM server
2U 1U 1U 1U 1U 2U
The
E P I I S B P U
E P I I S B P U
E P I I S B P U
E P I I S B P U
E P I I S B P U
V I E B S B P I
H B I U H S Y S
H S C U
H B I U H S Y S
H S C U
V I E B S B P I
E P I I S B P U
E P I I S B P U
C K I I
C K I I A L U I
BAM
Lan Switch 10M/100M Ethernet
WS or iManager N2000
SoftX3000
M2PA/M3UA
HBIU C K I I
HSCU ALUI
HSYS
PSTN
8k/2M Clock
IP BUS
S V B I P E I B
1*100M Ethernet
8 E1/T1
TDM interface
E P I I
IP interface
is SLPU
cascading
Back board Front board
HCOM SCBV
10M/100M Ethernet
Configuration of cascaded shelves Figure of the master service shelf in case of cascaded shelves
E P I I
S B P U
E P I I
S B P U
E P I I
S B P U
E P I I
S B P U
V I E B
S B P I
S C
B U
H B I U
H S Y S
H S C U
H B I U
H S Y S
H S C U
S C B U
H C O M
V I E B
S B P I
E P I I
S B P U
C K I I
C K I I
A L U I
H C O M
E P I I S B P U
E P I I S B P U
There arent CKII Board in slave shelves. Usually two frame need a pair of SBPI/VIEB board. A pair of VIEB need one IP address.
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal
HSYS Function
HUAWEI
HSYS
is the System board of the SG7000 and works in the 1 + bus configuration and status management with interface board through high-speed bus
1 backup mode.
High-speed
Communicating Managing
all boards in the service processing shelf and with background through Ethernet interface
HSYS Interface
HUAWEI
Type
Parameter RS232 serial interface RS422 master/slave serial interface RS485 serial interface 10/100M Ethernet interface 1 1 2
Index
Remarks For debugging purpose, with panel RJ45 socket and hot-plugging protection Communicating with EPII, ALUI, CKII and SCBU
Interface
Working with HBIU to provide back physical interface Working with HBIU to provide back physical interface
HSYS Indicator
HUAWEI
For board Flashing when board is normal (1 s on and working status 1 s off) For highspeed bus status
1 each
Both are on for active HSYS Both are off for standby HSYS
HSCU Functions
HUAWEI
HSCU
HSCU Indicator
HUAWEI
Indicator
DOMA DOMB indicator
Color Green
Note
1 each
Normal status
When both are on, the HSYS that is in pairs with the HSCU is active; otherwise, it is standby
CKII Functions
HUAWEI
CKII
is the Clock board of the SG7000, inserted in the master service shelf
and occupying two slots. It provides level-2 standard synchronization clock for the SG 7000 system, working in 1+1 backup mode.
The
Clock
Remarks
2 2
output interface
The
SBPU Functions
HUAWEI
SBPU
SBPU Interface
HUAWEI
SBPU interface
Type Interface
Parameter
Index 1
Remarks
For debugging purpose, with panel RJ45 socket and hot-plugging protection.
Indicator
RUN
Note
Meaning
For SLPU pinch board working status For SLPU pinch board link status
Normal status
It is flashing normally (1 s on and 1 s off) when the SLPU pinch board is normal. It is off when the board is abnormal. It is flashing fast (5 times /second) when SLPU is not configured at background. It is off when the board is configured and link is configured. When the SLPU is configured, link is configured but the link is not located, it is flashing slowly (1 time/second). When the board is configured, link is configured and link is located, it is off. If is off when the board is normal, and off when the board is faulty. It is flashing (1 s on and 1 s off) when the board is in normal status. It is flashing fast at 4Hz in loading. It is on when the board is inserted into shelf and before the power-on, and it is also on when the board is unplugged from the shelf.
ALM
Yellow
Yellow Green
1 1
Hot-plugging indicator
Blue
SLPU Functions
HUAWEI
It
of SBPU), and each SLPU can process 16 * 64K signaling links or can process one 2M high-speed signaling links.
There
are 32*64K signaling links or can process 2*2M high-speed signaling links totally.
SBPI Functions
HUAWEI
As
SG7000, SBPI implements the LAN drive of Broadband Interface and IP distributor unit functions,
SBPI Interface
HUAWEI
SBPI interface
Type
Index
Remarks For debugging purpose, with panel RJ45 socket and hot-plugging protection. Working with VIEB to provide back physical interface
1
1
Interface
SBPI Indicators
HUAWEI
SBPI
indicators
Color
Green 1
Indicator
LINK indicator
Note
Meaning
For network connection
Normal status
It is on when the physical connection is normal, and is off in other cases.
ACT indicator
Green
It is flashing in case of data transmitting/receiving, For network interface data traffic and the flashing frequency indicates the data traffic
For error status
Fail indicator
Yellow
Run indicator
Green
Flashing at 4 Hz in loading program Flashing at 1 Hz in normal running Flashing at 0.5 Hz for standby status
During the board is inserting in the subrack, the blue indicator is on, indicating that the board contacts the backplane. Here, the handle on the front panel can be used to insert the board completely into the backplane. When the board is to be unplugged, pull out the handle on the front panel, and then the blue indicator is on, indicating that the board is ready for unplugging.
Hot-plugging indicator
Blue
For hot-plugging
HCOM Functions
HUAWEI
HCOM
HCOM Interface
HUAWEI
HCOM
interface
During
Remarks
HCOM Indicator
HUAWEI
Indicator
LINK indicator ACT indicator
Note
2 2 1 1 1
Meaning
For network connection
Normal status
It is on when the physical connection is normal, and is off in other cases. It is flashing in case of data transmitting/receiving, and the flashing frequency indicates the data traffic It is on when the board is resetting or in error. It is flashing (1 s on and 1 s off) when the board is in normal status, and fast flashing at 4 Hz in loading. It is on when the board is inserted into shelf and before the power-on, and it is also on when the board is unplugged from the shelf.
Yellow
Green
For network interface data traffic For error status For running status For hotplugging
Hot-plugging indicator
Blue
ALUI Functions
HUAWEI
ALUI is the monitoring board of the SG7000, in slots 16 of the service processing shelf. It indicates the system status and reports the Alarm information from other sources. It monitors the back board fault and in-position statuses. It is connected with the equipment management board through differential serial interface, reports the collected information, and receives commands from equipment management board for controlling indicators. It detects the shelf temperature and sends the data to equipment management board through differential serial interface. It collects fault detection signals and in-position signals from three power modules, synthesizes them logically, and reports them to the equipment management board as the power system working status.
When the temperature sensor does not work normally, it reports error message, and the board FAIL indicator is on at the same time.
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal
ALUI Interface
HUAWEI
ALUI interface
Type
Interface
Parameter
RS232 serial interface
Index
1
Remarks
When the board J5 and J7 are configured for shorting modules, this serial interface is used as a RS422 serial interface to connect the HSYS. When J6 and J7 are configured for shorting modules, this serial interface is used as a standard RS232 serial and is led out from the front panel.
ALUI Indicators
HUAWEI
ALUI indicators
Color
Green/red 1
Location
RUN indicator
Note
Meaning Red
For board running Fault with the communication with HSYS
Off
Fault with board
00
01 02 03 04 05
Green/red
Green/red Green/red Green/red Green/red Green/red
1
1 1 1 1 1
Normal running
Normal running Normal running Normal running Normal running Normal running
ALUI Indicators
HUAWEI
ALUI indicator
Color Green/red
1
Note
Meaning Red
For board running Fault with the communication with HSYS Fault with board Fault with board Fault with board Fault with board Fault with board Fault with board All of the three power modules are in position, but one is faulty. The fan shelf is in position, but any of the six fans is faulty.
Off
Fault with board
10
11 12 13 14 15 PWR
Green/red
Green/red Green/red Green/red Green/red Green/red Green/red
1 1 1 1 1 1 1
For back board status For back board status For back board status For back board status For back board status For back board status
Normal running Normal running Normal running Normal running Normal running Normal running All of the three power modules are in position and are working normally. The fan shelf is in position, and all fans are working normally.
Board not in position Board not in position Board not in position Board not in position Board not in position Board not in position None of the three power modules is in position. The fan shelf is not in position.
For the statuses of three power modules For the status of fan shelf and the six fans
FAN
Green/red
As
version board is SEPU board ,provides 16-port E1/T1 interface. must have the same slot number with SBPU, but SEPU support
EPII Interfaces
HUAWEI
Interface table
Type
Parameter E1 interface
Index
8
Remarks
For connecting narrowband signaling network
Interface
2
2
EPII Indicators
HUAWEI
Indicators Color Note Meaning For board working status Normal status It is flashing (1 s on and 1 s off) when the board is working normally, and is off when the board is abnormal.
Location
RUN
Green
ALM
Yellow
It is flashing (1 s on and 1 s off) when the board is abnormal, and is off when the board is normal
EPII Jumpers
HUAWEI
S1:
S2
S4:
S5:
HBIU Functions
HUAWEI
The
It
port signal of the system board, and implements two physical interfaces for this asynchronous serial port.
It
It
HBIU Interfaces
HUAWEI
Interfaces
Parameter 10/100 BT1 (Ethernet interface for back out-leading of system board) Index Remarks
Type
1
1 each
Interface
Not used
HBIU Indicators
HUAWEI
Indicators
Indicator HD
Color Green
Note 1
4 ON ON ON ON ON ON ON ON
5 ON ON ON ON ON ON ON ON
6 ON ON ON ON ON ON ON ON
7 ON ON ON ON ON ON ON ON
8 ON ON ON ON ON ON ON ON
SCBU Functions
HUAWEI
The
connect two core LAN Switches in the SG7000 system. It assists the data switching between shelves, and sends the link data on the high-speed bus to be forwarded to other shelves to the LAN switches through network interfaces, which are then sent to the other service processing shelves to implement the mutual communication between shelves.
It provides one external E1 channel and provides one data channel for the system test.
SCBU Indicators
HUAWEI
Indicators
Type
Parameter
Ethernet interface 4Mbps interface E1 interface HW
Index
2 For
Remarks
inter-shelf connection and
communication
Interface
For test
SCBU Indicators
HUAWEI
Indicators
Location
Color
Note
Normal status It is flashing (1 s on and 1 s off) when the board is normal, and is off when the board is abnormal
RUN
Green
ALM
Yellow
It is flashing (1 s on and 1 s off) when the board is abnormal, and is off when
One debugging serial interface J8, one debugging network interface J9 and
VIEB Functions
HUAWEI
As the back board of SBPI, the VIEB provides the back out-leading Ethernet
VIEB Interfaces
HUAWEI
Interfaces
Type
Index
Remarks
Interface
Communication
Communication through high-speed bus Inter-board bus bandwidth 2Gbps information frames 2 for high-speed and low-delay exchange of
High-speed bus
S B P U
S B P U
S B P I
H C O M
H C O M
S B P I
S B P U
S B P U
Communication
The boards that have CPU and are not attached to the high-speed bus in the service shelves are controlled uniformly by the master/slave serial interface bus, including clock board CKII, E1/T1 interface board EPII and monitoring board ALUI.
A L U I H S Y S H S Y S
C K I I
C K I I
EPII
EPII
S C B U
S C B U
EPII
EPII
EPII
Clock access
2048kbit/s 2048KHz
BITS
E1 line
C K I I C K I I CLKA, CLKB E P I I E P I I
Active Standby
...
Security Level: Internal
Primary Secondary
Confidential Information of Huawei. No Spreading without Permission.
Primary
Secondary
The CKII board has three clock sources: BITS clock, E1 clock and CKII board local crystal oscillator. In the master clock shelf, the TDM switching bus abstracts two groups of clocks
In the master clock shelf, the EPIIs (PM and SM) abstracts clocks from CKII. The TDM switching bus of every shelf abstracts two groups of clocks CTA and
All EPIIs in the clock shelves abstract clocks from the TDM switching bus in the local shelf. The CTA has a higher priority and the CTB has a lower one. The CKII board local crystal oscillator can provide 2-level clocks, so that the SG clock can be locked externally.
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal
0 Slot
15 . . . 0
0 Slot
7 6 5 4
SLPU
(Upper)
SLPU
(Lower)
15 . . . 0
3 2 1 0
SBPU
EPII
Security Level: Internal
SG Frame-0
IP:172.6.1.6
HSYS
SG Frame-1
IP:172.6.2.6
HSYS
IP:172.8.1.8
HSYS
IP:172.8.2.8
HSYS
LanSwitch1
LanSwitch2
Internal network
IP:172.6.0.6
IP:172.8.0.8
BAM
IP:190.1.1.70 (for example)
VLAN IP:190.1.1.5
LanSwitch
External network
WS1
Confidential Information of Huawei. No Spreading without Permission.
WS2
WS17
Lesson Contents
HUAWEI
Service
Environment Background
(HSYS)
High-speed bus
TDM switching bus
IP interface (FE)
IP interface unit
(VIEB)
(SBPI)
Local high-speed bus
Narrowband signaling processing unit
HW
(SBPU)
EPII
(SLPU)
The
The power monitoring board of the power distributor box monitors the
working status of the power distributor box. It is connected with the HBIU of the HSYSs back board through serial interface, collecting the working statuses of the power distributor box and reporting to the HSYS.
It is composed of background administration module (BAM), charging server (BAU), management and maintenance workstation and remote management
System loading
The HSYS implements loading from BAM in the FTP mode through network card 1 and network card 2. The SBPU/SBPI implements loading through the HSYS of local shelf. The SLPU programs and data are loaded through the SBPU.
Equipment management
Lesson Contents
HUAWEI
Chapter 1 SG7000 Hardware Structure Chapter 2 SG7000 Logical Structure Chapter 3 SG7000 Message Flow
10M/100M interface
IP network
E1/T1 interface
PSTN, PLMN etc. No.7 signaling network
Monitoring unit
Confidential Information of Huawei. No Spreading without Permission.
Clock unit
Message Flow
HUAWEI
PSTN/PLMN signaling message -> SG7000 narrowband E1/T1 interface unit -> TDM switching bus and inter-shelf connection -> Implementing intra-shelf or inter-shelf semipermanent connection -> Signaling processing unit determines to forward the signaling message to PSTN/PLM or broadband IP network according to the destination
packets/unpackets the messages. After the IP distribution by the LAN drive and IP distributor unit, the
messages arrive at the IP network through the IP interface unit.
The flow is the converse case for the signaling processing from IP network to traditional narrowband network.
Confidential Information of Huawei. No Spreading without Permission. Security Level: Internal