WMPT WBBPa WRFU UBFA UEIU UELP UFLP UPEU WCDMA Main Processing and Transmission Unit WCDMA Baseband Process unit Type A WCDMA Radio Filter Unit Universal BBU Fan Unit Type A Universal Environment Interface unit Universal E1/T1 Lighting Protection unit Universal FE/GE Lighting Protection unit Universal Power and Environment Interface Unit
UAEU
UIEU UTRP DCDU-01 CPRI PSU PMU APM
Page 6
UTRAN
Iu
CN
RNC
Iub Iu-BC NodeB
Iu-CS
CS Iu-PS
Iur
NodeB PS
Iu-BC
Iub
NodeB
RNC
CBC
Page 7
UE
BTS3900 System
Page 8
Chapter 1 NodeB Overview Chapter 2 BTS3900 Hardware Structure Chapter 3 BTS3900 Typical Configuration
Page 9
Page 10
BTS3900 Appearance
Type Dimensions Empty cabinet Weight under full configuration 3*1 and 3*2 Weight - 48V : Input range of voltage +24V: Input range of voltage Parameters 600(W)*900(H)*450(D) 70kg 160Kg 120Kg -38.4V DC to -57V DC +21.6 V DC to +29 V DC
200 V AC to 240 V AC
200 V AC/346 V AC to 240 V AC/415V AC Working Temperature
-20+50
Page 11
9U
19U 2U
1U
1U
2U 1U 2U
3U
Page 13
BTS3900 can support up to: uplink 1536 CEs and downlink 1536 CEs
Page 14
-48V
PSU
Power Module
DCDU
WRFU
Iub RNC Baseband Transmission Control module BBU WRFU RF Module Antenna
Signal
Current
Page 15
Page 16
Clock mode
Signaling Processing
Operation& Maintenance
Power mode
Demodulation
Power Control information
RNC
Codling
Modulation
Transport Subsystem
Baseband Subsystem
Page 17
Typical configuration
Mandatory boards and modulesWMPT, WBBP, UBFA, and UPEU The optional boards are the UELP, UFLP, UTRP, and UEIU.
Page 18
WBBP
WBBP WBBP
UTRP
WMPT WMPT
Slot 0
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6 available
Slot 7 available
available available
available available
available available
available available
Page 19
4E1:DB26
Board number
Providing OM functions Controlling other boards in the system and providing the reference clock Providing USB ports for automatic NodeB upgraded Providing transmission port for Iub interface
Providing OM channels
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 20
Label RUN
Color Green
Description The board has power input, yet the board is faulty. The board has no power input. The board is running as configured. The software is being loaded to the board, or the board is not in use. The board is reporting hardware alarms. The board is running properly. The board is in active mode. The board is in standby mode.
ALM
Red
ON OFF
ACT
Green
ON OFF
Page 21
Color Green
Status ON OFF
Description The connections are functional. The connections are faulty. There is ongoing data transmission. There is no data transmission.
Yellow
Blinking OFF
Green
Yellow
ON
OFF Blinking OFF
Page 22
SW1 for setting the E1/T1 working mode SW2 for setting the protection ground for the E1.
Settings of SW1 Bit 1 2 3 4 T1 Mode ON ON OFF OFF 120-ohm E1 Balanced Mode OFF OFF ON ON 75-ohm E1 Unbalanced Mode ON ON ON ON
Settings of SW2 Bit 120-ohm E1 Balanced Mode 75-ohm E1 Unbalance d Mode Description
1
2 3 4
OFF
OFF OFF OFF
ON
ON ON ON
Page 23
Providing the CPRI interface for communication between the BBU and the
WRRU or WRFU Processing uplink and downlink baseband signals and support HSUPA and HSDPA function
OFF
1s ON, 1s OFF 0.125s ON/OFF ACT Green ON
OFF
ALM Red OFF ON OFF CPRI0 CPRI1 CPRI2 Red Green ON Blinking at 2 Hz Blinking at 0.5 Hz
Page 25
Board Type WBBPa WBBPb1 WBBPb2 WBBPb3 Cell 3 cells 3 cells 3 cells 6 cells
Downlink R99 CE 256 64 128 256 HSDPA Capacity 45 HS-PDSCH codes 45 HS-PDSCH codes 45 HS-PDSCH codes 90 HS-PDSCH codes
WBBPb4
6 cells
384
384
90 HS-PDSCH codes
30Mbps
12Mbps
Page 26
Controlling the fan speed Reporting the fan status to the WMPT
Page 27
-48V to +12V
+24V to +12V
Converting -48 V or +24 V DC power input to +12 V DC power that is supported by boards Reporting alarms related to input and output under voltage
Providing transmission ports for RS485 signals and 8 dry contact alarm signals
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 28
Label RUN
Color Green
Status ON OFF
Description The board is running properly. The board has no power input, or the board is faulty.
Socket and Port: The UPEU has one socket and four ports.
Label
PWR EXT-ALM1 EXT-ALM0 MON1
Quantity
1 1 1 1
Connector Type
3V3 RJ45 RJ45 RJ45
Function
DC power input Transmitting dry contact alarm signals Transmitting RS485 environment monitoring signals
MON0
RJ45
Page 29
The UTRP provides ports for eight E1s/T1s and implements transport such as IP and ATM between the BBU3900 and the RNC.
4 E1:DB26
Label RUN
Color Green
Status ON OFF 1s ON, 1s OFF 0.125s ON, 0.125s OFF 2s ON, 2s OFF
Description The board has power input, yet the board is faulty. The board has no power input or is faulty. The board is running properly. Software is being loaded to the board. The board is under test. The board is in active mode.
ACT
Green
ON
OFF
ALM Red OFF ON
Page 30
UTRP board should add sub board to provide the different interface type. WD22UTRP is the main board name. The UTRP has three sub-boards in current version UAEU: Eight ATM over E1s/T1s UIEU: Eight IP over E1s/T1s UUAS: One unchannelized ATM over SDH/SONET(STM-1/OC-3) interface The board Sub board Transmission in gray table is not be delivered currently. Interface type Board name name
WD22UEEU WD22UEOU WD22UAEU WD22UIEU WD22UCPU WD22UUPU WD22UCAU WD22UUAU WD22UEEC WD22UEOC WD22UAEC WD22UPEC WD22UCPS WD22UUPS WD22UCAS WD22UUAS FE/GE electrical board FE/GE optical board E1/T1 ATM interface sub board E1/T1 IP interface sub board Channelization IP optical sub board Unchanneliazation IP optical sub board Channelization ATM optical sub board Unchanneliazation ATM optical sub board Interface specification 2*FE/GE (10/100/1000M adaptive) 2*FE/GE (10/100/1000M configurated) 8* E1/T1 8*E1/T1 1*STM-1 1*STM-1 1*STM-1 1*STM-1
Page 31
Connecting to an external monitoring device and transmitting RS485 signals to the WMPT
Page 32
UELP
protection unit is an optional module of the BTS3900 cabinet (-48 V) or the power distribution cabinet.
The UFLP and the UELP
Page 33
The UELP can be optionally installed in the SLPU or the BBU. Each UELP supports the surge protection of 4-way E1/T1 signals. DB25
DB26
E1 Connection:
E1 E1
Indoor DDF
Page 34
DIP Switch S1
Description Used for the 75 unbalanced mode Used for other modes except the 75 unbalanced mode
Page 35
IP Cable Connection.
Transmission Equipment LAN switch or Router
Page 36
Page 37
The WRFU consists of the high-speed interface unit, signal processing unit, power amplifier, and duplex unit
Page 38
CPRI1
RX-INB
RX-OUTA
PWR MON
Page 39
Status
On Off On for 1 second and off for 1 second On for 0.125 second and off for 0.125 second
Meaning
The power input is normal, but the module is faulty. There is no power input, or the module is faulty. The module is functional. The module is loading software or is not started. The module is in the alarm status. No alarm is generated. The module is functional and is connected to the BBU. The module is not connected to the BBU. The module is in the local test status. No VSWR alarm is generated. A VSWR alarm is generated. The CPRI link is normal. The interface module fails to receive signals. The CPRI link is out of lock.
ALM
On Off
ACT
VSWR
CPRI0 CPRI1
On (green) On (red) Red LED on for 1 second and off for 1 second
Page 40
One WRFU supports four carriers Each carriers maximum output power of WRFU is 80W The receive sensitivity of single antenna is better than -125.8dBm The receive sensitivity of two antennas is better than -128.6dBm
Page 41
Page 42
- 48 V DC Distribution
Page 43
Page 44
Page 45
The DCDU-01 supports one -48 V DC power input and ten -48 V DC power outputs The DCDU-01 supplies power to the BBU, WRFU, FAN, and user devices inside cabinets The DCDU-01 has the built-in surge protector, which supports the surge protection capability of the differential mode of 10 kA and the common mode of 15 kA
- 48V DC Single Cabinet HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 46
Converting +24 V DC power to -48 V DC power and leading the -48 V DC power to the DCDU Monitoring alarms related to module faults ,alarms related to module protection and power out-of-position alarm
(1) Power running LED (2) Protection LED (3) Fault LED
+ 24V DC Single Cabinet HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 48
The power subrack consists of the PMU, PSU (AC/DC) and the wiring unit of the power subrack (220 V). The power subrack (AC/DC) converts the 220 V AC power to the -48 V DC power.
Yellow
Off On
Red
Off
On
Page 50
(2) Power supply test ports (4) Battery control switches (1) Backplane port (2) DIP switch
Page 51
second
If the PMU does not communicate with the main control unit
for one minute, the communication fails. In this situation, the RUN LED blinks four times every second.
The PMU is faulty (not in the power-on self-check state). The following alarms are reported: Mains overvoltage or undervoltage alarm Busbar overvoltage or undervoltage alarm Power module alarm Load shutdown alarm
Off
No alarm is generated.
Page 52
Page 53
Bit 2
0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1
Bit 1
0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
Bit 0
0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1
Monitoring Address
0000 0001 0010 0011 0100 0101 0110 0111 1000 1001 1010 1011 1100 1101 1110 1111
DIP Switch: The DIP switch is located on the rear panel of the PMU. The DIP switch has eight bits, which are set to OFF before delivery.
0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
Page 54
FAN Unit
The FAN unit refers to the fan box. The FAN unit provides the functions of ventilation
and heat dissipation for cabinets. One FAN unit has four independent fans.
Type
Power port Temperature sensor port
Label
-48 V SENSOR
Connector Type
3V3 power connector RJ45 connector
Description
Introducing the -48 V DC power Connecting the external temperature sensor Cascading the lowerlevel FAN module Connecting the main control unit Page 55
Communication port
Page 56
Page 57
OT terminal
Name PGND cable of the BTS3900 WCDMA cabinet PGND cable of the DCDU PGND cable for the SLPU Front door PGND cable
Color Green and yellow Green and yellow Green and yellow Green and yellow
Cross-Sectional Area The cross-sectional area of a wire is 25 mm2. The cross-sectional area of a wire is 6 mm2. The cross-sectional area of a wire is 6 mm2. The cross-sectional area of a wire is 6 mm2.
Page 58
Page 59
E1 Cable
FE Cable
Page 60