Slide 1
Slide 2
Quenchmaster Schematic
Main Pump
Pump Discharge
Pump Suction Inlet Foam Inlet
Inductor Drive Water Pump By-Pass to Appliance Water Tank Foam Proportioning Valve
Foam Concentrate
Edition 1 May 2009
20Lt
Slide 3
Slide 4
To Supply Foam
Ensure adequate supply of foam concentrate. Start pump and set pressure between 600 & 1000 kPa (Optimum 700 kPa ) DO NOT EXCEED 1000 kPa. Open branch to provide water flow through the pump and foam proportioner Ensure tank fill valve is closed ( Do not open during foam use )
The Red indicator will be on the drive water solenoid will be On for the entire duration of foam production
Foam solution will circulate around the pump for foam delivery
Slide 5
In the event that class A foam is required to be produced when the appliance is boosting, the following procedure must be followed.
Once water is being delivered to the branch, the pump inlet will need to be gated so as the pump inlet gauge reads as close to 0 as possible. ( This will ensure that there is no back pressure on the inductor ) Adjustments to the pump throttle will have to be made to maintain required pressure.
Edition 1 May 2009
Slide 6
percentage valve to the Off position. Red indicator light will turn off and the orange flush indicator light will illuminate.
Slide 7
Every time the pump ignition is turned on the drive water solenoid will open allowing water to flush and lubricate the system Ensure the foam proportioning valve is turned Off If foam enteres the appliance water tank during firefighting / training operations, flush the water tank until free of foam.
Slide 8
Slide 9
Slide 10
Foam concentrate is stored in 20 litre carboys located in a slide out carrier under the appliance. A pick-up tube delivers foam concentrate from the carboys to the inductor.
Slide 11
During foam production/use the tank fill valve must remain closed If this valve is opened during foam use contamination of the water tank will occur
Slide 12
Pump Cooling
When the class A foam valve is in the foam off position, water is circulated back to the water tank therefore providing pump cooling capacity.
When the class A foam valve is in the on position, the pump by-pass line is closed and the water is diverted to the foam inductor. In this position there is no pump cooling capacity
Edition 1 May 2009
Slide 13