Você está na página 1de 65

Natural Gas Engine Drive Air Compressor Training

Industrial Center, Inc. Chicago, Illinois April 9, 1997


Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training Ingersoll Rand -1-

Air Compressor Basics Presented By:


Allen L. Humphrey
Industrial Marketing Manager
Ingersoll-Rand Company Portable Compressor Division Air Compressor Group Mocksville, North Carolina
Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training Ingersoll Rand -2-

Hi !, Im an expert in Natural Gas !

Isnt all gas natural!!!

Gas Company Guy


Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Air Compressor Guy


Ingersoll Rand -3-

Im an expert in compressed air,! Hot air, cooled, and dried

I'm in trouble now, another guy full of hot air!!!

Air Compressor Guy


Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Gas Company Guy


Ingersoll Rand -4-

Outline:
I. Compressed Air Facts

II.
III.

Compressed Air Technologies


Regulation & Controls

IV.
V.

System Location and Arrangement


Compressor System Components The Basics
Ingersoll Rand -5-

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Compressed Air Facts

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand -6-

Compressed Air Facts

Most facilities consider compressed air a utility on par with electricity, gas, and water However, few operating people know the real operating cost of their compressed air system

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand -7-

What is cost per CFM ?

A Good Approximation Typical Compressor produces 4 CFM per 1 Hp 1 Hp = 0.746/0.9 = 0.829kW Therefore, 1 CFM = 0.207kW @ 0.06 $/kw-hr, 1 cfm = $0.0124/hr 10 CFM over 8000 hours costs 10 x 8000 x 0.124 = $ 992.00
Ingersoll Rand -8-

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Where are NORMAL savings ?


Fix System Leaks !! Standard plant air system


8000 hrs per year operation Electrical costs = $ 0.06/kWhr Plant line pressure = 100 PSIG

(1) 1/8th inch air leak = 26 CFM 26 x 8000 x $.0124/hr = $ 2,579.00 A typical plant can have air leaks = to 20% of total air usage.
Ingersoll Rand -9-

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Air Basics

Three Main Parameters


1. Pressure 2.Capacity 3. Horsepower

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand - 10 -

Pressure(PSI) = Pounds per Square inch

Completely dependent on system, controls and safety valves An unregulated compressor will make ever increasing pressure until a failure occurs When plant capacity demand exceeds system capacity(CFM), compressor discharge pressure will drop
Ingersoll Rand - 11 -

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Pressure - Capacity Relationship P1 x V1 = P2 x V2


P1= Initial pressure V1= Initial capacity P2= Final pressure V2= Final capacity If a system needs more capacity(CFM) than available, plant pressure drops in an unsuccessful trade of pressure for capacity
Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training Ingersoll Rand - 12 -

The Cost of Pressure


Good Rule of Thumb Each # (PSI) of system pressure = 0.5% of system horsepower

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand - 13 -

Pressure Cost Example

100Hp compressor set to discharge at 125 psig to plant system Plant system only requires 110 psig User resets compressor discharge pressure to 110 psig ( a 15 psi reduction) 15 PSI = 7.5 % of Hp = 7.5 Hp 7.5 x .746/.85 = 6.6kW x 8000 hrs x $.06/kWhr = $ 3,168.00 (Savings)
Ingersoll Rand - 14 -

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Capacity(Flow) = CFM(ft3per minute)


Basic measure of true compressor output A fixed value in most designs, for a given model Most all capacity measurements are referred back to inlet conditions. Capacity varies only slightly with a change in discharge pressure, for a given model

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand - 15 -

Capacity Measurement

In the pneumatics industry, ALL capacities are measured referring back to inlet conditions Various formulae are used to define capacity(CFM): SCFM; ACFM; ICFM; FAD, etc. Require your vendor to define which and where ASME and CAGI-Pneurop have generally accepted testing standards Capacity tolerances may vary from vendor to vendor. Request definition
Ingersoll Rand - 16 -

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Horsepower

Typically, electric motor nameplate HP or NG engine MCHP(Max Continous Hp) The work it takes to compress X CFM up to Y PSI Driver HP is usually fixed. If either CFM or PSI is increased, the driver may overload, unless regulation, a speed reduction, or a change in either CFM or PSI takes place. Horsepower tolerances may vary from vendor to vendor. Request definition
Ingersoll Rand - 17 -

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Air Basics Translations

Capacity(CFM) does the work; Pressure effects the rate at which the work is done A trending decrease in plant air pressure typically indicates a requirement for more capacity(CFM), not pressure Increasing or decreasing the existing compressor discharge pressure will normally have negligble effect on the compressor capacity

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand - 18 -

II. Compressed Air Technologies

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand - 19 -

Compressor Technology
Air Compressors

Positive Displacement

Dynamic Displacement

Reciprocating

Rotary Screw

Centrifugal

Single Acting

Double Acting

Oil Flooded

Oil Free

Single Stage

Two Stage

Lower Technology
Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Higher Technology
Ingersoll Rand - 20 -

Dynamic Displacement
Performance Curve
180 160 140 120 100 80 60 40 20 0
0% FL 20% 40% 60% 80% 100% 120%

Discharge Pressure PSI

Percent of Full Load


Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training Ingersoll Rand - 21 -

Centrifugal Compressors

Advantages

Only real option over 600+ Hp High air quality- 0 PPM oil carryover Moderate to high efficiency Longer design life than Rotaries Higher initial cost Fluid cooled only Power reduction down to 70% flow Constant speed operation
Ingersoll Rand - 22 -

Disadvantages

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Positive Displacement
180 160 140 120 100 80 60 40 20 0
0% FL

Performance Curve

Discharge Pressure PSI

20%

40%

60%

80%

100%

120%

Percent of Full Load


Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training Ingersoll Rand - 23 -

Positive Displacement

Reciprocating or Rotary Screw Designs


Constant cfm; Variable pressure Adaptable to variable speed drive Variable speed and unloading provide close alignment with system demand

Oil Flooded Rotary Screws--The design of choice for NGEDACs

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand - 24 -

Rotary Screw
Oil Flooded- Single Stage Advantages

Low 1st cost; Low maintenance $ Simple packaged design Adaptable to variable speed drive

Disadvantages

Somewhat lower efficiency Moderate durability - 10 15 years on average


Ingersoll Rand - 25 -

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Rotary Screw

Oil Free Advantages


High air quality- 0 PPM oil carryover Moderate efficiency Packaged design

Disadvantages

Higher initial cost Higher maintenance cost


Ingersoll Rand - 26 -

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Compressor Selection Criteria


Evaluated First Cost Efficiency Controls Maintenance Cooling Air Quality Durability
Ingersoll Rand - 27 -

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

General Guidelines- First Cost

Single-stage rotary screw


Typically lowest first cost Greatest market growth, largest population Typically lowest efficiency

Possible Alternatives
Two-stage rotary screw Oil free rotary screw* Centrifugal* *Dependent on air quality requirements

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand - 28 -

General Guidelines- Maintenance

Capabilities of on site maintenance personnel ? Contract maintenance ? Oil flooded rotaries typically require lowest maintenance Air-in-the-box design enables on site overhauls of both compressor system and engine
Ingersoll Rand - 29 -

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

General Guidelines- Cooling

Fluid-Air cooled - less expensive Most designs have fluid or fluidair cooled design options available Closed evaporative cooling towers; open towers and external fluid to air coolers are viable cooling options
Ingersoll Rand - 30 -

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

III. Regulation & Controls

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand - 31 -

Regulation/Controls Applications

Average number of compressors = 2.5 per facility Typical system controls: manual/ none Each incremental 1 PSIG of unnecessary pressure cost 0.5% of compressor horsepower Each electric motor driven compressor running unloaded = 35-50% of the full loaded electrical costs
Ingersoll Rand - 32 -

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Regulation Basics

Do not run compressors unnecessarily Evaluate current regulation parameters Consider upgrading substandard controls The most efficient operating point is 100% full load.

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand - 33 -

Basic Types of Regulation


This information will be covered in detail later in the seminar presentation

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand - 34 -

IV. System Location and Arrangement

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand - 35 -

Possible Locations
#1 FACILITY

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand - 36 -

Outdoors

Advantages

Zero floor space Zero heat load Potential weather damage (Freezing, water, etc.) Potential lack of maintenance (Out of sight, out of mind)
Ingersoll Rand - 37 -

Disadvantages

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Possible Locations
#1
FACILITY

#2

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand - 38 -

Indoors Centralized

Advantages

Protected from elements Potentially easier access


Greatest floor space Potentially long piping runs

Disadvantages

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand - 39 -

Possible Locations
#1 FACILITY

#3
#3

#2

#3

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand - 40 -

Indoors Decentralized

Advantages

Possible to install closest to large air users Least amount of pressure drop through air lines
Highest probability of incorrect regulation Potential to spread noise and heat complaints to broadest number of employees
Ingersoll Rand - 41 -

Disadvantages

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Environmental Factors

Temperature Ventilation Conditions

Atmosphere Personnel

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand - 42 -

Temperature - Low

Below 350 F

Possible control freeze problem Possible condensate freeze problem Possible fluid misapplication Heaters Heat tracing key elements Relocate
Ingersoll Rand - 43 -

Recommendations

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Temperature - High

Above 1000 F

Possible unit shutdown Increased engine maintenance Possible decreased lubricant life

Recommendations

Improved ventilation/relocate Higher performance lubricant More suitable equipment design


Ingersoll Rand - 44 -

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ventilation

Insufficient Ventilation

Possible unit shutdown Increased maintenance Possible decreased lubricant life


Air-cooled Water-cooled
Ingersoll Rand - 45 -

Requirements

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ventilation - The High Air Temperature (HAT) Vicious Cycle


Compressor Generates Heat Insufficient Ventilation Causes Heat To Remain Around Unit

Unit Temperature Spirals Upward


This Heat is Ingested By Engine-Compressor Increasing Operating Temperatures Of Unit
Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training Ingersoll Rand - 46 -

Miscellaneous Conditions

Atmosphere Personnel

These important subjects will be covered later in the Seminar

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand - 47 -

V. Compressor System Components-The Basics

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand - 48 -

Basic Selection Criteria

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand - 49 -

Real World Systems


Design Criteria Air Quality required by User Moisture content ? Oil carryover ? Contaminants Pressure Drop Demand Characteristics Energy profile
Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training Ingersoll Rand - 50 -

Ideal Components For a Compressed Air System


Compressor Aftercooler Wet Receiver Pre-Filter Dryer After Filter Dry Receiver
Ingersoll Rand - 51 -

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ideal Components Layout


Dry Receiver
Dryer

After-Cooler

Prefilter

Compressor Afterfilter WetReceiver

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand - 52 -

Dryers - Moisture Content


Rule of Thumb
Aftercooler
Air Compressor
100F 80F 60F

100% RH

100% RH 100% RH

Effect of Compressed Air Temperature on sizing of drying equipment. A 20 F reduction in temperature condenses 50% of the water vapor in saturated air.(Collect it; trap it; dispose of it)

A 20 F. rise in temperature doubles (200%) the moisture holding capacity of the air.
Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training Ingersoll Rand - 53 -

After Filter (Recommended)


Purpose Reduce oil carryover Benefit Improved air quality Improved product quality

Instrument air applications Painting


Ingersoll Rand - 54 -

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Dry Receiver (Recommended)


Purpose Provide a reservoir of clean dry air to meet fluctuating system demands Benefit When sized and installed correctly can minimize airline pressure fluctuations Prevents short term capacity requirements from overloading cleanup equipment
Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training Ingersoll Rand - 55 -

Real World Systems


Moisture Content Pressure Dewpoint - Temperature at which water vapor condenses into liquid in a compressed airline Rule of thumb: Select a dewpoint 10-200 F below the lowest temperature the compressed airlines will see

Real World Systems


WARNING:
This applies only to general industrial application. Specific applications have specific dewpoint requirements (i.e., paint booths, instruments, etc.)
Contact equipment OEMs

Real World Systems


Typical Real World System A 1000 CFM system with

lowest plant ambient temperature of 600 F sensitivity to lubricant fairly steady plant demand

Real World System


AfterCooler Wet Receiver
Dryer

Afterfilter

Compressor

Air Cooled 1000 CFM Compressor 1000 gallon receiver

oil coalescing filter


Refrigerated air dryer with a 400 F dewpoint

Real World Systems


Pressure Drop Pressure Drop is the cost of air quality

Every air clean up device will utilize 2-10 PSI to perform its function

Air dryers typically 3-5 PSI Air filters typically 2-10 PSI (dependent on how long the element has been in place)

Remember @ 1/2% energy for each PSI, additional filters may become needlessly expensive

Real World Systems


Demand Characteristics Receiver size and placement varies depending on plant demand cycle and receiver size Possible to supply a new intermittent large air user with a properly sized and installed receiver tank

Real World Systems


Typical Compressor Carryover Values:
Reciprocating Compressors Lubricated Non - Lubricated

50-100 PPM 0 PPM 3-10 PPM 0 PPM 0 PPM

Rotary Compressors Oil Flooded Oil Free


Centrifugal Compressors

Real World Systems


Oil Content Requirements Whether the oil is removed at the compressor, or at the point of use, should be determined by overall plant requirements

Real World Systems


WARNING:
Although some equipment may benefit from (or even require) lubricant in compressed air, many other applications (paint booths, instrumentation) cannot tolerate it Again overall system requirements should dictate system design

Air Compressor Basics


Thank you for your kind attention

Industrial Center, Inc. / Air Compressor Consortium N.G.E.D.A.C. Training

Ingersoll Rand - 65 -

Você também pode gostar