How Thermo TRACE GC Ultra was structurally concepted: Mainframe - Oven Overview Injectors - Detectors Overview Detector base body concept Gas ModulesOverview Detectors Overview
Keypad
3
Injections Overview
Split/Splitless
PTV
It allows
GC top deck
Oven
.....................................
Injector modules include injector body, electronics for injector temperature and carrier gas control. Detector modules include detector cell and electronics for signal amplifier digitalization, for temperature and detector gas control. TRACE 1300 TRACE 1310 can accommodate 2 inlet and 2 detector modules (2 channels) self-recognized Additional external devices can be located into dedicated housing.
10
11
12
13
TRACE GC Ultra
Injector
DPFC/DCC module
Power control
14
TRACE GC Ultra
Detector Base body DGFC module Detector board Thermoregulator
(I/O Feedback board)
15
TRACE GC Ultra
CPU Board I/O Feedback board Mother board Power supply
16
TRACE GC Ultra
GC Keypad
17
TRACE 1310
Instrument Control
18
TRACE 1310
Configuration
19
TRACE 1310
Diagnostics
20
TRACE 1310
Status
21
TRACE 1310
Maintenance
22
Direct connection to PC (reversed RED cable) Connection to LAN (standard GREY cable)
Two RS-232 ports for Autosampler control Thermo Fisher bus I2C with 5V power for additional auxiliary devices
23
24
From the PC, launch the Setup.exe file named TR1300ST (Service Tool) entering ThermoFisher as password, then, press OK. This SW load the whole package zip file as it is. Do not change any file inside.
25
26
27
28
29
30
31
32
HMI SW can be updated through the USB port positioned below the touch screen
33
34
..............more in depth
35
36
Depth (mm)
40 50 60 70 80 90 100 100
Septa is kept below 150C even with inlet set to 350C Lower septum bleeding (siloxanes) No septum sticking Lower air (oxygen) diffusion Longer septa lifetime The cool head SSL is optimized for cold needle injection
150 200 250 T (C) 300 350 400
37
Pneumatics:
Electronic control only Constant pressure Constant flow Flow regulation through calculated pressure Pressure or flow programming in three ramps and four plateaus
Pressure range:
0 to 1000 KPa, with a resolution of .015 KPa, and stability of 0.1 KPa along the entire scale
Flow ranges:
Column flow from 0.1 to 100 ml/min, with resolution of 0.01 ml/min Split flow from 10 to 1250 ml/min He with resolution of 1mL/min Septum purge flow from 0 to 50 ml/min with resolution of 1mL/min Ambient temperature and pressure compensation Gas saver function Split /Split less Surged Split/Surged Split less Large Volume Split less Back-flush capability (*) NOTE: Standard SSL CANNOT BE converted to SSL BKF a new module MUST BE requested.
Operating modes:
38
39
40
Pneumatics:
Operating modes:
Split, Splitless, Solvent Split (Large Volume) Back-flush capability (*) NOTE: Standard PTV CANNOT BE converted to PTV BKF a new module MUST BE requested.
41
42
43
44
45
47
48
49
50
main switch
toroidal transform
fan motor
oven
H2 sensor (optional)
51
heating element
RTD
front view
back view
52
53
Breaker
Main CPU
54
Injection position
55
Injection position
56
57
58
59