The OptiX OSN 3500 II equipment consists of the cabinet, cabinet doors, DC power distribution unit (PDU), sub racks, boards, and cables. The OptiX OSN 3500 II sub rack can be installed in a 300 mm or 600 mm ETSI cabinet.
2/9/2014
ALT/OFC/MADM
PQM
D7 5S
PIU
PIU
AU X
FAN
FAN
FAN
SLO T1
SLO T2
PQ 1
SLO T3
SLO T4
SLO T5
SLO T6
SLO T7
SLO T8
SLO T9
SLO T 10
SL 64
SL 64
XC S
XC S
SLO T 11S
SLO T 12S
L6 4
L64
SLO T 13
SLO T 14
SLO T 15
SLO T 16
SLO T 17
SLO T 18
SC C
SC C
2/9/2014
ALT/OFC/MADM
Fiber Routing
1. DC PDU 2. Side panel 3. Upper sub rack 4. Lower sub rack 5. Fiber management tray 6. Front door
2/9/2014
Figure ALT/OFC/MADM
In the case of the OptiX OSN 3500 II, the output terminal blocks on side A and side B can supply power to the power interface boards in slots 1 and 41. In this manner, the equipment has two DC inputs that back up each other.
2/9/2014
ALT/OFC/MADM
Mapping Relation Between Slots for Interface Boards and Slots for Processing Boards
Slots for Processing Boards Slots for Interface Boards Slots for Processing Boards Slots for Interface Boards
Slot 6
Slot 7
Slots 27 and 28
Slots 29 and 30
Slot 15
Slot 16
Slots 37 and 38
Slots 39 and 40
5
2/9/2014
ALT/OFC/MADM
bytes pass through the backplane bus between two slots, the two slots are paired slots. When an NE is configured with an order wire phone, realizes the service protection . The two boards that form a ring must be inserted in the paired slots.
Slot Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 slot 9
2/9/2014
2/9/2014
ALT/OFC/MADM
2/9/2014
ALT/OFC/MADM
The front panel of the board has the following indicators: Board hardware status indicator (STAT) two colors (red and green) Active/Standby state indicator of the cross-connect unit (ACTX) one color (green) Active/Standby state indicator of the SCC unit (ACTC) one color (green) Board software status indicator (PROG) two colors (red and green) Service alarm indicator of the cross-connect unit (SRVX) three colors (red, green, and yellow) Service alarm indicator of the line unit (SRVL) three colors (red, green, and yellow) Synchronization clock status indicator (SYNC) two colors (red and green) Alarm mute indicator (ALMC) one color (yellow)
2/9/2014
ALT/OFC/MADM
NOTE
For details on the board version replacement relation between boards, table of board version replacement relations in the Parts replacement.
ALT/OFC/MADM 10
2/9/2014
2/9/2014
ALT/OFC/MADM
11
Parameter Launched optical power range (dBm) Optical signal-to-noise ratio (dB) Receiver sensitivity (dBm)
2/9/2014
Features of SL 16 Fixed wavelength output. Automatic laser shutdown (ALS) function. Support VC-4-4C, VC-4-8C and VC-416C services. Inloop and out loop function. Setting and querying of the REG working mode.
ALT/OFC/MADM 13
2/9/2014
SL4
Receives and transmits 1xSTM-4 optical signals, and processes1xSTM-4 standard or concatenation services. SL4 can be installed in slots 28 and1116 in the sub rack.
2/9/2014
ALT/OFC/MADM
14
SEP1
The SEP1 is a line board. The SEP1 can be used on the OptiX OSN equipment series to transmit and receive STM-1 optical/electrical signals. The SEP1 converts the received optical signals into electrical signals and sends the electrical
signals to the cross-connect side
The front panel of the board has the following indicators: l Board hardware status indicator (STAT) two colors (red and green) l Service activation status indicator (ACT) one color (green) l Board software status indicator (PROG) two colors (red and green)
SEP1 is used with the interface board, the SEP1 can be installed in slots 37 and1216 in the subrack.
2/9/2014
ALT/OFC/MADM
15
PDH Unit
Features of PQ1 Interface Type: 75 or 120 Support In loop and out loop functions Support Warm and Cold reset
2/9/2014
ALT/OFC/MADM
16
The front panel of the board has the following indicators: l Board hardware status indicator (STAT) two colors (red and green) l Service activation status indicator (ACT) one color (green) l Board software status indicator (PROG) two colors (red and green) l Service alarm indicator (SRV) three colors (red, green, and yellow) l Connection status indicator (LINK) one color (green) l Data receiving and transmission indicator (ACT) one color (orange)
2/9/2014
ALT/OFC/MADM
17
Protection scheme
None
None
Description
Index
*Restoration time<2s
BW Utilization Revenue
Medium High
High Medium
Highest Lowest
* Reference only , according to different networks & fibers cuts , the time is different