Você está na página 1de 18

OptiX OSN 3500 II (MADM)

The OptiX OSN 3500 II equipment consists of the cabinet, cabinet doors, DC power distribution unit (PDU), sub racks, boards, and cables. The OptiX OSN 3500 II sub rack can be installed in a 300 mm or 600 mm ETSI cabinet.

2/9/2014

ALT/OFC/MADM

Configure a double ADM:


Tributary Unit : 2M PQ1: slot 2 Line Unit : STM-64 SL64: slot 8, 11 slot 7, 12
SLO T 19 SLO T 20 SLO T 27 SLO T 28 SLO T 37 SLO T 29 SLO SLO SLO T 30 T 31 T 32 SLO SLO T 33 T 34 SLO SLO T 35 T 36

PQM

D7 5S

D7 SLO SLO SLO SLO SLO SLO 5S T 21 T 22 T 23 T 24 T 25 T 26

PIU

PIU

AU X

FAN

FAN

FAN

SLO T1

SLO T2

PQ 1

SLO T3

SLO T4

SLO T5

SLO T6

SLO T7

SLO T8

SLO T9

SLO T 10

SL 64

SL 64

XC S

XC S

SLO T 11S

SLO T 12S

L6 4

L64

SLO T 13

SLO T 14

SLO T 15

SLO T 16

SLO T 17

SLO T 18

SC C

SC C

2/9/2014

ALT/OFC/MADM

Fiber Routing

OptiX OSN 3500 II subrack.

1. DC PDU 2. Side panel 3. Upper sub rack 4. Lower sub rack 5. Fiber management tray 6. Front door

2/9/2014

Figure ALT/OFC/MADM

OptiX OSN 3500 II

Front Panel of PDU

In the case of the OptiX OSN 3500 II, the output terminal blocks on side A and side B can supply power to the power interface boards in slots 1 and 41. In this manner, the equipment has two DC inputs that back up each other.

2/9/2014

ALT/OFC/MADM

Mapping Relation Between Slots for Interface Boards and Slots for Processing Boards
Slots for Processing Boards Slots for Interface Boards Slots for Processing Boards Slots for Interface Boards

Slot 3 Slot 4 Slot 5

Slots 21 and 22 Slots 23 and 24 Slots 25 and 26

Slot 12 Slot 13 Slot 14

Slots 31 and 32 Slots 33 and 34 Slots 35 and 36

Slot 6
Slot 7

Slots 27 and 28
Slots 29 and 30

Slot 15
Slot 16

Slots 37 and 38
Slots 39 and 40
5

2/9/2014

ALT/OFC/MADM

Slots & Paired slots Of OptiX OSN 3500 II


Overhead

bytes pass through the backplane bus between two slots, the two slots are paired slots. When an NE is configured with an order wire phone, realizes the service protection . The two boards that form a ring must be inserted in the paired slots.
Slot Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 slot 9
2/9/2014

Paired Slot Slot 16 Slot 15 Slot 14 Slot 13 Slot 12 Slot 11 slot 10


ALT/OFC/MADM

Optix OSN 3500 II Sub-rack


Configure 1 Access capacity 40G 2.5G 14 5G 1

2/9/2014

ALT/OFC/MADM

Optix OSN 3500 II Sub-rack

Configure 2 Access capacity 90G 2.5G 2 5G 9 10G 4

2/9/2014

ALT/OFC/MADM

Cross-Connect Boards and System Control Boards


The front panel of the board has the following indicators: Board hardware status indicator (STAT) two colors (red and green) Active/Standby state indicator of the cross-connect unit (ACTX) one color (green) Active/Standby state indicator of the SCC unit (ACTC) one color (green) Board software status indicator (PROG) two colors (red and green) Service alarm indicator of the cross-connect unit (SRVX) three colors (red, green, and yellow) Service alarm indicator of the line unit (SRVL) three colors (red, green, and yellow) Synchronization clock status indicator (SYNC) two colors (red and green) Alarm mute indicator (ALMC) one color (yellow)

2/9/2014

ALT/OFC/MADM

Classification of the Boards

Bar Codes of the Boards


The bar code on the front panel of a board indicates the version, name, and feature code of the board. 16-digit manufacturing code + board version + board name + board feature code

Classification of the Boards


The boards are classified into SDH boards, PDH boards, data boards, WDM boards, and auxiliaryboards according to the functions of the boards.

NOTE
For details on the board version replacement relation between boards, table of board version replacement relations in the Parts replacement.
ALT/OFC/MADM 10

2/9/2014

Bar code of a board

2/9/2014

ALT/OFC/MADM

11

Appearance of the front panel of the SL64


The front panel of the board has the following indicators: Board hardware status indicator (STAT) two colors (red and green) Service activation status indicator (ACT) one color (green) Board software status indicator (PROG) two colors (red and green) Service alarm indicator (SRV) three colors (red, green, and yellow
SL64 converts the received optical signals into electrical signals and sends the electrical signals to the cross-connect side. In addition, the SL64converts the electrical signals sent from the cross-connect side into optical signals and transmits the optical signals.

Parameter Launched optical power range (dBm) Optical signal-to-noise ratio (dB) Receiver sensitivity (dBm)
2/9/2014

Value -4 to -1 Without the FEC: 26 -14


ALT/OFC/MADM 12

SDH Unit (SL 16)

Features of SL 16 Fixed wavelength output. Automatic laser shutdown (ALS) function. Support VC-4-4C, VC-4-8C and VC-416C services. Inloop and out loop function. Setting and querying of the REG working mode.
ALT/OFC/MADM 13

2/9/2014

SL4

Receives and transmits 1xSTM-4 optical signals, and processes1xSTM-4 standard or concatenation services. SL4 can be installed in slots 28 and1116 in the sub rack.

2/9/2014

ALT/OFC/MADM

14

SEP1

The SEP1 is a line board. The SEP1 can be used on the OptiX OSN equipment series to transmit and receive STM-1 optical/electrical signals. The SEP1 converts the received optical signals into electrical signals and sends the electrical
signals to the cross-connect side

The front panel of the board has the following indicators: l Board hardware status indicator (STAT) two colors (red and green) l Service activation status indicator (ACT) one color (green) l Board software status indicator (PROG) two colors (red and green)
SEP1 is used with the interface board, the SEP1 can be installed in slots 37 and1216 in the subrack.

2/9/2014

ALT/OFC/MADM

15

PDH Unit

Features of PQ1 Interface Type: 75 or 120 Support In loop and out loop functions Support Warm and Cold reset

2/9/2014

ALT/OFC/MADM

16

Functions and features of the EGT2

The front panel of the board has the following indicators: l Board hardware status indicator (STAT) two colors (red and green) l Service activation status indicator (ACT) one color (green) l Board software status indicator (PROG) two colors (red and green) l Service alarm indicator (SRV) three colors (red, green, and yellow) l Connection status indicator (LINK) one color (green) l Data receiving and transmission indicator (ACT) one color (orange)

2/9/2014

ALT/OFC/MADM

17

Provide Multiple levels of service: SLA


Index Service level Diamond Gold Silver Copper Iron

Protection scheme

Permanent 11 Protection 1 + 1 Protection + Restoration 1 + 1 Protection

Virtual Ring Protection Virtual Ring Protection + Restoration

Dynamic Restoration Pre-Calculating Restoration Shared Mesh Restoration

None

None

Description

Provide permanent protection for service when network resource is utilizable

Performs as protection most of the time, if protection is invalid, restoration works

Real-time restoration of service, no need of standby resource

Index

Protection time <50ms

Protection time50ms *Restoration time2s

*Restoration time<2s

BW Utilization Revenue

low Very high

Medium High

High Medium

Very high low

Highest Lowest

* Reference only , according to different networks & fibers cuts , the time is different

2/9/2014

ALT/OFC/MADM

18

Você também pode gostar