Contents
PQ is a Business Problem
Power Quality issues cause business
problems such as:
Lost productivity, idle people and equipment
Lost orders, good will, customers and profits
Lost transactions and orders not being
processed
Revenue and accounting problems
Customer and/or management dissatisfaction
Overtime required to make up for lost work
time
3
GE Consumer & Industrial
Multilin
Jan 28, 2015
4
GE Consumer & Industrial
Multilin
Jan 28, 2015
5
GE Consumer & Industrial
Multilin
Jan 28, 2015
6
GE Consumer & Industrial
Multilin
Jan 28, 2015
Who is Affected?
High Cost Facilities
o Semiconductor plants
o Pharmaceuticals
o Data centers
Medium Cost Facilities
oAutomotive
manufacturing
oGlass plants
oPlastics & Chemicals
oTextiles
Lost production
Scrap
Costs to restart
Labor costs
Equipment damage and repair
Other costs
7
GE Consumer & Industrial
Multilin
Jan 28, 2015
PQ Definitions Revisited
IEEE Categories
Std 1159-1995
Short Duration
Variations
Typical
Duration
Instantaneous Sag
0.5 30 cycles
Momentary Sag
30 cycles 3
sec
Temporary Sag
3 sec 1 min
8
GE Consumer & Industrial
Multilin
Jan 28, 2015
PQ Definitions Revisited
IEEE Categories
Std 1159-1995
Short Duration
Variations
Typical
Duration
Instantaneous Sag
0.5 30 cycles
Momentary Sag
30 cycles 3
sec.
Temporary Sag
3 sec 1 min.
Instantaneous Swell
0.5 30 cycles
Momentary Swell
30 cycles 3
sec.
Temporary Swell
3 sec 1 min.
9
GE Consumer & Industrial
Multilin
Jan 28, 2015
PQ Definitions Revisited
IEEE Categories
Std 1159-1995
Short Duration
Variations
Typical
Duration
Instantaneous Sag
0.5 30 cycles
Momentary Sag
30 cycles 3
sec.
Temporary Sag
3 sec 1 min.
Instantaneous Swell
0.5 30 cycles
Momentary Swell
30 cycles 3
sec.
Temporary Swell
3 sec 1 min.
Momentary
Interruptions
0.5 30 cycles
Temporary
Interruptions
30 cycles 3
sec.
10
GE Consumer & Industrial
Multilin
Jan 28, 2015
PQ Definitions Revisited
IEEE Categories
Std 1159-1995
Long Duration
Variations
Typical
Duration
Sustained
interruptions
> 1 min
Under voltages
> 1 min
Over voltages
> 1 min
11
GE Consumer & Industrial
Multilin
Jan 28, 2015
PQ Definitions Revisited
IEEE Categories
Std 1159-1995
Long Duration
Variations
Typical
Duration
Sustained
interruptions
> 1 min
Under voltages
> 1 min
Over voltages
> 1 min
Voltage imbalance
Steady state
Waveform
Distortion
12
GE Consumer & Industrial
Multilin
Jan 28, 2015
PQ Definitions Revisited
IEEE Categories
Std 1159-1995
Long Duration
Variations
Typical
Duration
Sustained
interruptions
> 1 min
Under voltages
> 1 min
Over voltages
> 1 min
Voltage imbalance
Steady state
Waveform
Distortion
DC offset
Steady state
Harmonics
Steady state
Inter harmonics
Steady state
Sources of PQ Problems
Utility Sources
Lightning
PF Correction Equipment
Faults
Switching
Internal Sources
Individual Loads Lighting, Elevators,
Coolers, HVAC
Uninterruptible Power Supplies
Variable Frequency Drives
Battery Chargers
Large Motors During Startup
Electronic Dimming Systems
Lighting Ballasts (esp. Electronic)
Arc Welders, and Other Arc Devices
Medical Equipment, e.g. MRIs and X-Ray
Machines
Office Equipment and Computers
Wiring
14
GE Consumer & Industrial
Multilin
Jan 28, 2015
Disturbance Type
Possible Causes
Overheated neutral
Intermittent lock-ups
Frequency deviations
Steady-state
Shared neutrals
Improper or inadequate
wiring
High source impedance
SCR/Rectifiers and notching
Harmonics
15
GE Consumer & Industrial
Multilin
Jan 28, 2015
Disturbance Type
Possible Causes
Overheated neutral
Intermittent lock-ups
Frequency deviations
Steady-state
Shared neutrals
Improper or inadequate
wiring
High source impedance
SCR/Rectifiers and notching
Harmonics
Interruption
Garbled data
Random increase in harmonics
levels
Utility faults
Inrush currents
Inadequate wiring
16
GE Consumer & Industrial
Multilin
Jan 28, 2015
Disturbance Type
Possible Causes
Overheated neutral
Intermittent lock-ups
Frequency deviations
Steady-state
Shared neutrals
Improper or inadequate
wiring
High source impedance
SCR/Rectifiers and notching
Harmonics
Interruption
Garbled data
Random increase in harmonics
levels
Intermittent lock-ups
Lights flicker
Garbled data
Utility faults
Inrush currents
Inadequate wiring
Sags/Swell
17
GE Consumer & Industrial
Multilin
Jan 28, 2015
Disturbance Type
Possible Causes
Overheated neutral
Intermittent lock-ups
Frequency deviations
Steady-state
Shared neutrals
Improper or inadequate
wiring
High source impedance
SCR/Rectifiers and notching
Harmonics
Interruption
Garbled data
Random increase in harmonics
levels
Utility faults
Inrush currents
Inadequate wiring
Intermittent lock-ups
Lights flicker
Garbled data
Sags/Swell
Component failure
Dielectric breakdown
Lock-ups
Garbled data
Wavy CRTs
Impulses
EMI/RFI
Lightning
Load switching
Capacitor switching
Static discharge
Hand-held radios
Loose wiring/arcing
18
GE Consumer & Industrial
Multilin
Jan 28, 2015
Disturbance Type
Possible Causes
Overheated neutral
Intermittent lock-ups
Frequency deviations
Steady-state
Shared neutrals
Improper or inadequate
wiring
High source impedance
SCR/Rectifiers and notching
Harmonics
Interruption
Garbled data
Random increase in harmonics
levels
Utility faults
Inrush currents
Inadequate wiring
Intermittent lock-ups
Lights flicker
Garbled data
Sags/Swell
Component failure
Dielectric breakdown
Lock-ups
Garbled data
Wavy CRTs
Impulses
EMI/RFI
Lightning
Load switching
Capacitor switching
Static discharge
Hand-held radios
Loose wiring/arcing
Harmonics
Electronic loads
SCR/rectifier
19
GE Consumer & Industrial
Multilin
Jan 28, 2015
Major PQ Problems
Outages,
6%
Spikes, 7%
Swells,
Sags, 56%
31%
Source: EPRI, 1994
Swells
Sags (Dips)
20
GE Consumer & Industrial
Multilin
Jan 28, 2015
$10
$100k
Source: EPRI The Economics
k of Custom Power, IEEE T&D Show 2003
$1M
$10
M
Momentary Outages
create problems
when computers and
clocks reset,
equipment stalls, and
work stops.
Category
Industrial
Semiconductor Manufacturing
Electronics
Automobile Manufacturing
Pharmaceutical
Glass
Rubber and Plastics
Petrochemical
Food Processing
Textile
Metal Fabrication
Mining
Paper
Printing(Newspapers)
Commercial
Hospitals, banks, civil service
Communications, information processing
Resturants, bars, hotels
Commercial shops
$20.0
$8.0
$5.0
$5.0
$4.0
$3.0
$3.0
$3.0
$2.0
$2.0
$2.0
$1.5
$1.0
$60.0
$12.0
$7.5
$50.0
$6.0
$4.5
$5.0
$5.0
$4.0
$4.0
$4.0
$2.5
$2.0
$2.0
$1.0
$0.5
$0.1
$3.0
$10.0
$1.0
$0.5
22
GE Consumer & Industrial
Multilin
Jan 28, 2015
Benefits of Continuous PQ
Power Quality monitoring provides a
Monitoring
continuous Health Check of a facilitys
power system for example:
o
o
Transients
switching
It provides
data tofrom
see, load
diagnose
and are
seen problems like squeaky
avert looming
brakes on a car
o
24
Records,
GE Consumer & Industrial
Multilin
and Leads to the Prevention of PQ Problems Jan 28,
2015
Be easy to use
Be Suitable for continuously
Transients
monitoring indoors and
Interruptions
outdoors
Sag/Under Voltage
Interface with standard PQ
Swell/Over Voltage
analysis SoftwarePQDif
Waveform Distortion
format
Voltage Fluctuations
Be fast enough to capture high
Frequency Variations
speed events that produce
equipment problems
Have enough storage to save
These include Flicker and
Compliance to ITI(CBEMA), IEEE
the waveforms you need
and ISO Standards
Have PQ analysis tools that
produce
usable,
actionable
ITI: Information Technology Industry Council (Computer & Business Equipment
Manufacturers
Association)
25
recommendations GE Consumer & Industrial
Multilin
Jan 28, 2015
Equipment Interrupting
Voltage Sags as Recorded
27
ITI: Information Technology Industry Council (Computer & Business Equipment Manufacturers Association)
GE Consumer & Industrial
Multilin
Jan 28, 2015
28
GE Consumer & Industrial
Multilin
Jan 28, 2015
29
GE Consumer & Industrial
Multilin
Jan 28, 2015
30
GE Consumer & Industrial
Multilin
Jan 28, 2015
Flicker Recording
31
GE Consumer & Industrial
Multilin
Jan 28, 2015
Flicker Recording
32
GE Consumer & Industrial
Multilin
Jan 28, 2015
Summary
GE Multilin provides the necessary tools for a successful PQ
disturbance analysis and allows users to take remedial actions
Symptoms
Feels the pulse of the
power system network
Accurate Measurement
Examinations
to determine actual
state High resolution
recordings for longer
Diagnosis
durations
GE Communicator
software
Remedy
Remedial actions
33
GE Consumer & Industrial
Multilin
Jan 28, 2015
Finally
If You Cant Measure it You Cant
Manage it
If You Can Measure it You Can
Manage it
34
GE Consumer & Industrial
Multilin
Jan 28, 2015