Security Level: Internal

OMCR Operation Guide


Alex

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

www.huawei.com

Agenda

OMCR
M2000
BSC6000
Principles in OMCR

OMCR Introduction

Location of OMCR
M2000 Platform
OM interface
Traffic Stats (Excel)
Alarm (Excel)

HUAWEI TECHNOLOGIES CO., LTD.

KPI
Repor
t

OMCR

Huawei Confidential

Page 3

OMC Routine Task


Modifying Parameters
Collecting Data
Data Configuration
Traffic Statistics
Signaling Trace

Monitoring Alarms
DT Cooperation

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 4

Agenda

OMCR
M2000
BSC6000
Principles in OMCR

M2000 Overview

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 6

M2000-Log in BSC6000 LMT(on


line)

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 7

M2000-Query Traffic Statistics


Object
Object
Setting
Setting

HUAWEI TECHNOLOGIES CO., LTD.

Counter
Counter
Setting
Setting

Other
Other
Setting
Setting

Huawei Confidential

Get
Get
Results
Results

M2000-Alarms

Querying Current Fault Alarms


Right Click on the site or BSC, and select Browse current Fault Alarms.

Querying History Fault Alarms


Right click on to the site or BSC, go to the Alarm Query > Query History
Fault Alarms.

Querying Custom Alarms


Select the shortcut Current Fault Alarm Query
Configure parameters

Object
Alarm Level
Alarm Type
Alarm Status

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 9

Alarms degrade KPIs


BSC Alarms

MSC Overload
Cell Out of Service
LAPD OML Fault
Lack TC Resource
LAPD Link Congestion

HUAWEI TECHNOLOGIES CO., LTD.

BTS Alarms:

LAPD Alarm
Radio Link Prompt Alarm
TRX Hardware alarm
TRX VSWR alarm
Main receive channel alarm
Diversity receive channel alarm
TRX communication alarm
Clock Reference Abnormal Alarm
E1 Remote Alarm /E1 Local Alarm
Level 1 VSWR Alarm
Level 2 VSWR Alarm

Huawei Confidential

Page 10

Agenda

OMCR
M2000
BSC6000
Principles in OMCR

BSC6000 O&M
LMT(GUI)
Manage Data Configuration
Manage BTS
Signaling Trace
Alarm Maintenance
MML(Script)
Manage Data Configuration
Manage BTS
Alarm Maintenance

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 12

LMT-Data Configuration

Querying Data Configuration


Modify Data Configuration
Batch Modify Data Configuration
Backup lmt.dat to Local PC
Query Data Configuration in table

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 13

LMT-BTS Maintenance(1)

HUAWEI TECHNOLOGIES CO., LTD.

Level 3 reset: Based on the configuration data of the BTS


stored in the memory.
Level 4 reset: Based on the data configuration stored in the
database (DB), the BSC updates the data stored in the
memory, and then configures the BTS again to reset it.
Huawei Confidential

Page 14

LMT-BTS Maintenance(2)

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 15

LMT-BTS Maintenance(3)

One SDCCH has 8 sub-channels. One half rate TCH has 2 subchannels.
The status of a channel is identified according to the color. You can put the mouse
point on a dot to view the status of a sub-channel.
If a TRX number has a sign * on its upper right, the TRX is in mutual aid state.
HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 16

LMT-BTS Maintenance(4)

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 17

LMT-BTS Maintenance(5)

Query the maximum and average values


of the main level and diversity level in a
frequency scan period.
HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 18

LMT-BTS Maintenance(6)

Manually set the network to maximum interference mode


to obtain the maximum interference of the entire
network. Testing idle timeslot refers to sending idle
Burst bit stream to the unseized timeslots to set the
network to maximum interference mode.
HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 19

LMT-Signaling Trace

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 20

MML Introduction

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 21

MML-Commands

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 22

MML-Batch Command(1)

Generating Batch MML Command:


Step1: generate one correct MML command.
Step2: paste multiple lines in Ultra Edit.
Step3: Using Column Mode to edit object
Step4: Replacing spaces and Save.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 23

MML-Batch Command(2)

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 24

Agenda

OMCR
M2000
BSC6000
Principles in OMCR

Principle in OMCR

Follow the time schedule and rules for engineer to enter and leave OMC
room.
Do not eat and drink in OMC room, and do not bring glasses into OMC
room.
Different O&M clients use different user names and passwords. Usually
OMC room operators manage and distribute user names and passwords
to everyone, so do follow related rules when using them.
Do not perform other operations except necessary RNP&O operations,
such as board reset and system parameter modification.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 26

CR Procedure
1. RNO engineers propose a request for modifying parameters, and sent it
to OMCR manager (customer or Huawei) for approval.
2. After OMCR managers approve it, RNO engineer send CR to OMC room
operators.
3. OMC room operators execute related modifying action. Do feed back the
modifying result to RNO engineers and OMCR manager by Email. If OMC
room operators fail to modify parameter, RNO engineers must analyze
the reason till the operation is close.
4. If parameters modification is just for temporary or testing, OMC
operators should restore the parameters after test.
5. Pay attention to parameter importance, parameter level, and parameter
impact on the system. Select the right time to avoid accidents. It is
strongly recommended to modify parameters at midnight.