Você está na página 1de 81

The VNXe Series

Technical Presentation

Name
Title
October 2011

Copyright 2011 EMC Corporation. All rights reserved.

Topics
Architecture
Hardware
Operating
Environment
Storage Pools
Data Services
Thin Provisioning
File-level
Deduplication &
Compression
Data Protection
Snapshots
Replication
Copyright 2011 EMC Corporation. All rights reserved.

Data Services
(continued)
Antivirus
File Level Retention
Backup

Windows Integration &


Support
Management
Support Ecosystem

Simple. Efficient. Affordable.

Configure in
A
new
seconds
Get
more
way
capacity at
to
less cost
think
Rest
easy,
rock
solid
about
Starting
shared
under $10K

storag
e

Copyright 2011 EMC Corporation. All rights reserved.

Architecture & Hardware

Copyright 2011 EMC Corporation. All rights reserved.

VNXe's Purpose Designed


Architecture
Integrated Unified Storage
Designed for IT generalist

iS
CS
N I
FS
CI
FS

Maximizing simplicity and easy


of use
(no X-Blades, Control Stations
etc.)
Providing balanced
performance, scalability and
flexibility
e
rag
Sto sor A
ces
Pro

Performanc
e
(SAS)

e
rag
S t o so r B
c es
Pro

Highest
Capacity
(NL-SAS)

Multi-core
Processors

SP A

Shared Memory Resources

SP B

SP A

VNXe OE

File
Block
EMC Apps
Unisphere

VNXe OE

File
Block
EMC Apps
Unisphere
Flare

Backend
Backend disks
disks

Flexible Drive
Options

Copyright 2011 EMC Corporation. All rights reserved.

VNXe Series Hardware


Simple. Efficient. Affordable.

Form factor (Minimum)


Storage Processors (SPs)
Total System memory
Maximum drives (Single or Dual
SP)

Drive types

VNXe 3100

VNXe 3300

2U

3U

1 or 2

4 or 16 GB

24 GB

48 or 96

120

3.5 SAS, NL-SAS

3.5 SAS, NL-SAS, Flash

Protocols
Embedded I/O ports per SP
Configurable I/O slots per SP
I/O slot options available
Backend Connectivity per SP

Copyright 2011 EMC Corporation. All rights reserved.

NFS , CIFS, iSCSI


2 X 1 Gb Ethernet

4 X 1 Gb Ethernet

4 x 1 Gb Ethernet

4 x 1 Gb Ethernet
2 x 10 GB Ethernet

4 x 6Gb/s SAS

4 x 6Gb/s SAS

VNXe3100 2U Platform Overview


Chassis

Front View 12
x 3.5 Disks

Rear

Storage
Processor

Copyright 2011 EMC Corporation. All rights reserved.

2U DPE (Disk Processor


Enclosure)
6Gb SAS-2 drive interface
Max 12, 3.5 Drives per
enclosure
Dual Energy Star Gold Power
Supplies
Power Consumption ~
330W
1 or 2 SPs - CPU Module
Canisters
Battery-backed Write Cache
(BBWC) for single SP
configurations
Dimensions: 20in depth x 3.5in
height x ~19in width

I/O Technology per


SP
One Back End SAS-2
Port
( 6 Gb/s x4)
Two Embedded GbE
Host Ports
One I/O Slot per CPU
module
4 x 1GbE
GbE Management
Port
Serial Console and
USB Port

2 CPU Modules, each


containing
Intel, Dual Core Processor
2, DDR3 1066MHz DIMM slots
Integrated, 3-cell Li-ion BBU

Cost-effective Data Persistence


Cache Protection

Module

Single Storage Processor


Configuration
Low cost entry point in the VNXe
Series
Upgradeable to dual processor
configuration

Cache Protection Module


Fits into second storage processor
slot

Vault-to-Flash (VTF) technology


Runs off of low-power battery
technology
No need for standby power supplies

VNXe3100 - Single SP System recovery


Memory contents restored from SSD
Configuration
Buffer and cache pools/pages are
recreated at same physical
addresses as initial boot
System verifies restore operation
and resumes I/O processing

Copyright 2011 EMC Corporation. All rights reserved.

VNXe3300 3U Platform Overview


Chassis

3U, DPE (Disk Processor


Enclosure)
6Gb SAS-2 drive interface
Max 15, 3.5 Drives per
Front View 15 x 3.5
enclosure
Disks
Holds 2 SP Suitcases with
Integrated Cooling
Dual Energy Star Gold Power
Supplies
Power Consumption ~ 500W
with 15 drives
Rear
Battery Backup Module in Power
Supply
Dimensions: 24in depth x 5.25in
height x ~19in width
NEBS Level 3
DC Power option
Storage
Processor

I/O Technology per


SP
One Back End SAS-2
Port (6 Gb/s x4)
Four Embedded GbE
Host Ports
One I/O Slot per CPU
module
4 x 1GbE,
2 x 10GbE
GbE Management Port
Serial Console and
USB Port

2 CPU Modules, each


containing
Quad Core Processors
3 DIMM Slots with 3 channels @
800MHz

Copyright 2011 EMC Corporation. All rights reserved.

Flexible Storage Capacity


Disk Options, 3.5 Drives

Flexible Storage

Options

SAS Performance: 300GB, 600GB,


15K RPM
Near line SAS Capacity: 1TB, 2TB,
7.2K RPM
Flash (Tier 0): 100GB (VNXe3300
only)

Scale
Up to 7 additional disk enclosures per
system
Max 120 drives in VNXe3300
Max 96 drives in VNXe3100
Mix drive types within an enclosure

Optional disk pack offerings


SAS Performance pack: RAID 5 or
RAID 10
SAS Capacity pack: RAID 6
Flash pack: RAID 5

Scale to 240 Terabytes with 2TB drive


Copyright 2011 EMC Corporation. All rights reserved.

10

Modular Design
Modular system design
All major components are
customer replaceable units
Easy to identify and access

Simple to service and upgrade


Clear visual repair instructions
Tool-less access to replaceable
components
How-to videos

Minimal component sparing


Efficient CRU replacement process

Copyright 2011 EMC Corporation. All rights reserved.

11

VNXe Interoperability and Standards


Host Operating Systems
Microsoft Windows
Linux: SUSE, Red Hat,
AsiaNUX
UNIX: AIX, HP-UX, Solaris
VMWare
Hyper-V
Citrix XenServer

US Dept of Defense
Common Criteria
DISA STIG

Telecom
Telcordia NEBS Level 3

Storage Applications
NDMP Backup Software
Anti-Virus Scanning
Software

Copyright 2011 EMC Corporation. All rights reserved.

12

High Availability

Copyright 2011 EMC Corporation. All rights reserved.

13

High Availability
Platform
No single point of failure
n + 1 power and battery backup
Redundant, hot-pluggable components

Function
RAID protection
Active/Active controllers
Data cache mirroring between controllers
Battery-backed cache for single SP
configurations
Dynamic failover/failback
Automatic management control failover
Vault-to-Flash technology

Service
Non-disruptive upgrades
Hot-swap CRU and drive replacement
Remote maintenance, call-home, automatic
diagnostics

Copyright 2011 EMC Corporation. All rights reserved.

14

VNXe Vault to Flash Cache


Persistence
CIFS
Exchange
I/O

VNXe

File Services

Management
Services
File Services

Block Services

Block Services

Cach
Cach
e
e

Network, I/O, Service Shims


NIC

Cach
Cach
e
e

Memory
Cach
e

PCIe SAS

Platform
Services

Memory
Cach
e

Power
Down
Routin
e

Management
Services

Power
Down
Routin
e

192.168.5.2
IQN:C0T0L0
Platform
Services

1
2
.3
.
.

192.168.5.1
\\cifs\myshare

Network, I/O, Service Shims


PCIe SAS

NIC

3.2.Power
Down
Code
waits
for
complete
AC power
is lost
todump
array
Power1.
Down
Routine
sheds
unnecessary
Disables
battery
hold
up device
A battery
holds
up SPdraws
and
SSD
power
Transition to
special power
fail routine
Checksums
Contents
of memory
to dump
Initiates memory dump to SSD
Copyright 2011 EMC Corporation. All rights reserved.

15

16

PCIe SAS

NIC

Network, I/O, Service Shims


Block Services

PCIe SAS

NIC

Network, I/O, Service Shims


Block Services

File Services
Management
Services

Platform
Services

Copyright 2011 EMC Corporation. All rights reserved.

File Services
Platform
Services

Management
Services
192.168.5.1
\\cifs\myshare

192.168.5.2
IQN:C0T0L0

VNXe

I/O

VNXe Deployed and Operating


Normally
CIFS
Exchange

VNXe HA Services Support SP


Failure
CIFS
Exchange
I/O

VNXe

File Services
Block Services

Platform
Services

Management
Services

File Services
File Services

Block Services

Network, I/O, Service Shims


PCIe SAS

2
1
.

192.168.5.2
IQN:C0T0L0
Management
Services

3
.

192.168.5.2
IQN:C0T0L0

Platform
Services

192.168.5.1
\\cifs\myshare

NIC

Network, I/O, Service Shims


PCIe SAS

NIC

1.3.Cluster
Detects
problem
with
other
Health/Alert
2. HAManager
Service
Business
starts
new
Logic
file
detects
service
status
node is invoked
IP network failover
change
Validates
failure
Indicates
iSCSI LUNnode
Alert
is exported
to user
failover
Email AlertInvokes
to EMCHA
Support
& service
configured email
address
Copyright 2011 EMC Corporation. All rights reserved.

17

VNXe HA Services Support Service


Failure
CIFS
Exchange
I/O

3
.

192.168.5.2
IQN:C0T0L0

Block Services

Platform
Services

Management
Services
File Services

Block Services

Network, I/O, Service Shims


PCIe SAS

1
2
.

Mgmt IP
192.168.5.1

File Services

Mgmt IP
192.168.5.1

Management
Services

192.168.5.1
\\cifs\myshare

Platform
Services

VNXe

NIC

Network, I/O, Service Shims


PCIe SAS

NIC

3.
Business
Logic
detects
status
2.
1. Health/Alert
HA
Local
Service
Resource
starts
Manager
Management
Detects
Service
problem
on
change
Tries restarting
other
services
node 3 times
Indicates
Alert to
user
IPInvokes
network
HA
failover
failover
is service
invoked
Email
Alert indicates
to started
Supporton
and
configured
Management
Services
2nd
Storage
emails
Processor

Copyright 2011 EMC Corporation. All rights reserved.

18

VNXe HA Networking Feature


Support
Link Aggregation

VNXe Series

LINK
Switch

IEEE 802.3ad standard for port grouping; improves


availability
One port fails, other ports take over
Automatic configuration with statistical load balancing
based on source and destination MAC addresses

FAILSAFE NETWORKING PLUS TRUNKING


IMPLEMENTATION
Primary paths

Standby paths

Switch

Switch

Sales
Accountingdatabas
E-mail database e
server server
server

NetWar
e
file
server

UNIX
file
server

Network configuration beneficial against switch &


cable failures
End-to-end network availability

VLAN, 802.1Q-VNXe in a VLAN-enabled network


Added security and Ease of management

UNIX file server VLAN


NetWare file server VLAN
Sales database server VLAN
Accounting database server VLAN
E-mail server VLAN

Accounting

FailSafe Networking (FSN)

Automatically configured between SPs

Network

VNXe
Series

Does not increase single-client throughput, may


increase throughput if there are multiple clients.

Sales

Engineeri
ng

Copyright 2011 EMC Corporation. All rights reserved.

19

Storage Pools

Copyright 2011 EMC Corporation. All rights reserved.

20

VNXe Storage Pools

Stage 2

Disks
Stage 1

Copyright 2011 EMC Corporation. All rights reserved.

21

VNXe Storage Pools

Stage 2

RAID Groups

Global Performance

Disks
Stage 1

Copyright 2011 EMC Corporation. All rights reserved.

22

VNXe Storage Pools

LUs
RAID Groups

Stage 2
Global Performance

Disks
Stage 1

Copyright 2011 EMC Corporation. All rights reserved.

23

VNXe Storage Pools

Disk Volumes
LUs
RAID Groups

Stage 2
Global Performance

Disks
Stage 1

Copyright 2011 EMC Corporation. All rights reserved.

24

VNXe Storage Pools


Stripe Volume
Disk Volumes
LUs
RAID Groups

Stage 2
Global Performance

Disks
Stage 1

Copyright 2011 EMC Corporation. All rights reserved.

25

VNXe Storage Pools


Pool Volume
Stripe Volume
Disk Volumes
LUs
RAID Groups

Stage 2
Global Performance

Disks
Stage 1

Copyright 2011 EMC Corporation. All rights reserved.

26

Data Services

Copyright 2011 EMC Corporation. All rights reserved.

27

Thick Provisioning Shared Folders


User provisions
a
Shared Folder
Pool Volume
Stripe Volume
Disk Volumes
Flare LUNs
RAID Groups and
Global Pools

CIFS Shared Folder

10 GB

Reserved storage (Size)

Pool Volume

Disks

18.5 GB

Copyright 2011 EMC Corporation. All rights reserved.

28

Twice the Efficiency


More storage, better utilization, lower cost
File
File
Deduplicatio
Deduplicatio
n and
n and
Compression
Compression

Traditional
Traditional
storage
storage

Copyright 2011 EMC Corporation. All rights reserved.

Thin
Thin
Provisioning
Provisioning

2X

more efficient

29

Thin Provisioning

Copyright 2011 EMC Corporation. All rights reserved.

30

Thin Provisioning Shared Folders


User provisions
a
Shared Folder
Pool Volume
Stripe Volume
Disk Volumes
Flare LUs
RAID Groups and
Global Pools

CIFS Shared Folder

5 GB

Allocated (Initial Size)

15
GB

Reserved storage (Maximum Size)

Pool Volume

Disks

18.5 GB

Copyright 2011 EMC Corporation. All rights reserved.

31

VNXe Thin Provisioning


Capacity oversubscription

VNXe THIN PROVISIONING


User A
10 GB

User B
10 GB

User C
10 GB

Logical
application
and user view
Physical
allocation

File systems
iSCSI LUNs
Logical size greater than physical
size

Physical allocation in real time


to logical size
4 GB

Physical
consumed
2 GB 2 GB storage

VNXe Virtual Provisioning


safeguards
Automatic File System
Extension past logical size
iSCSI Dynamic LUN Extension
past logical size

Copyright 2011 EMC Corporation. All rights reserved.

32

File-level deduplication

Copyright 2011 EMC Corporation. All rights reserved.

33

VNXe File-Level Deduplication and


Compression Architecture
VNXe FILE DEDUPLICATION

Deduplication processes:
Policy engine scans all production files
looking for data that meets certain criteria:

Deduplicationenabled file system

Last accessed/modified time, minimum/


maximum size, file extension, directory
Or, files selected via API
Candidates are compressed

File A

Stub A

File A

Stub A

File C

File B

Stub B

Stub C

File
StubAC
Stub B

File A
Compress and
deduplicate file
File B

File B

File C
Active
file

Duplicated files are removed by using SHA-1


or byte-by-byte data comparison
Stubs point to files in the hidden
deduplication store

Deduplication is transparent to clients:


Process runs in the background
Files pre- and post processing look the same
Hidden deduplication store is a working
area that is not visible

User visible
area

Hidden
deduplication
store

Reads decompress data in memory, not on


disk
Writes are stored alongside deduplicated data
Modifying one instance of a file has no impact
on other deduplicated instances

Copyright 2011 EMC Corporation. All rights reserved.

34

VNXe File Deduplication and


Compression: Data Modification
File modification does not cause file
to be reinflated:

VNXe FILE SYSTEM


User visible area
New Data

File Data

Hidden
reduced data
store
File Data

Allows targeting large files (Terabytes


sized), and files that may show some
level of activity while preserving user
experience on access to these files

Deduplicated files can be modified


while still preserving commonality:
New data is stored alongside old

File is either reinflated or


reprocessed when new+old reaches
logical file size:
Reinflated if selected for deduplication by
the internal policy engine
Reprocessed if selected for deduplication
via API

Copyright 2011 EMC Corporation. All rights reserved.

35

Data Protection

Copyright 2011 EMC Corporation. All rights reserved.

36

VNXe: Takes Care of the


Complexities of Data Protection
Problem:
Calculating the space required for data protection is complicated.
It require formulas and an intimate understanding of underlying
snapshot and replication technology.

Typical Result:
Data Protection either gets slapped together in a probably
should work fashion, or a Professional Services engagement is
required.

VNXe eliminates complexity by:


Integrating best practices for provisioning data protection
reserve space
Easy to configure snapshot schedules and Application Consistent
Snapshots
Simplified replication configuration and management
Copyright 2011 EMC Corporation. All rights reserved.

37

Data Protection Storage


Recommendations
VNXe provisioning best practices also cover Data Protection storage

Application specific best practices for data protection space.


Thin provisioning aware: Applications using thin provisioning will not require as much data protection
storage.
Auto-adjustment of Data Protection space as your production storage resource grows

Copyright 2011 EMC Corporation. All rights reserved.

38

Snapshots

Copyright 2011 EMC Corporation. All rights reserved.

39

The differences between Shared


Folder & iSCSI snapshots
Shared Folder snapshots use Copy On first
Write (COW)
Snapshot creation and deletion is very quick
The space required for snapshots continues to
grow as changes are made to the production
volume

iSCSI snapshots use Redirect on Write (ROW)


Snapshot creation is very quick
Perfect for your latency sensitive applications
Snapshots dont grow once created

Copyright 2011 EMC Corporation. All rights reserved.

40

Example: VNXe Shared Folder


Snapshot
Production file system
.ckpt_PFS_3PM
.ckpt_PFS_12PM
.ckpt_PFS_9AM
PFS files at 4PM
PFS files at 4PM
PFS files at 4PM
PFS files at 4PM

VNXe
Family

Production file system

Production
file system

Snapshot
Logical
point-intime copy

Provides a read-only or read-write, pointin-time view of data


File system-level or iSCSI LUN view
Multiple snapshot versions 96 r/o + 16 r/w
Typically has a 10% capacity overhead

Primary applications include


Simple user initiated file un-deletes
Efficient logical backup and restore

Restore PFS
to 12:00 p.m.
snap

.ckpt_PFS_4PM
.ckpt_PFS_3PM
.ckpt_PFS_12PM
.ckpt_PFS_9AM
4PM
PFS files at 12PM
4PM
PFS files at 12PM
4PM
PFS files at 12PM
4PM
PFS files at 12PM

Single SavVol
PFS_3PM
PFS_12PM
PFS_9AM

SavVol extended
Empty Space
PFS_4PM
PFS_3PM
PFS_12PM
PFS_9AM

Copy on first write technology


Avoids fragmentation of primary FS
One side file data protection space for all file
system snaps

Automatic extension of data protection


space
Online full file system instant restore from
any snap
Snaps can be deleted out of order

Copyright 2011 EMC Corporation. All rights reserved.

41

Snapshots Consistency Options


Crash consistent snapshots
VNXe provides the ability to create manual and
scheduled crash consistent snapshots through
Unisphere
Shared Folder:
Crash consistent snaps are acceptable

iSCSI:
Good for an emergency. Only applicable to applications
with a single virtual disk

Copyright 2011 EMC Corporation. All rights reserved.

42

Snapshots and Application


Consistency
iSCSI Application consistent snapshots
Using 3rd party backup applications
Leverages the VSS framework for Microsoft Applications to
create Hardware Snapshots for the application

Preferred Solution: Using the Application Protection Suite


Application protection Suite includes Replication Manager (RM)
software
An RM agent runs on the host, which guarantees the applications
using the storage are quiesced prior to creating snapshots
Leverages the VSS framework for Microsoft Applications
For applications with multiple virtual disks, Application Sets
ensure consistency across all the storage resources
Exchange will automatically undergo snapshot consistency
checks following the creation of the snapshot

Copyright 2011 EMC Corporation. All rights reserved.

43

Data Recovery options


Snapshots
Shared Folder: User initiated recovery using
hidden .ckpt directory or Microsoft Previous
Versions interface
iSCSI: Snapshot promotion and revert performed
using either Unisphere or RM

Microsoft Previous Versions


tab

Copyright 2011 EMC Corporation. All rights reserved.

44

Replication

Copyright 2011 EMC Corporation. All rights reserved.

45

VNXe Replication
Production
site

Disaster
recovery
remote site

Network

Network

FS/
LUN
VDM

FS/
LUN
VDM

WAN

Snaps

Snaps

Replication can be*:


VNXe to VNXe
VNXe to VNX
VNXe to Celerra (DART
6.0+)
Celerra (DART 6,0+) to
VNXe
VNXe to VNXe fan-out
& fan-in ratio 5 to 1

Same technology for


* See the EMC Simple Support Matrix (ESSM) for the VNXe Series, url:
file for
& any
block
Simple Support Matrix EMC VNXe Series
prerequisites and
requirements.
Copyright 2011 EMC Corporation. All rights reserved.

46

Replication Frequency
Shared Folder replication driven from Unisphere
Manual synchronization
Automatic synchronization based on RPO (Recovery Point
Objective)

iSCSI replication using RM


Schedule-driven synchronization frequency
Application consistency is guaranteed

Copyright 2011 EMC Corporation. All rights reserved.

47

Anti-Virus

Copyright 2011 EMC Corporation. All rights reserved.

48

VNXe Anti-Virus Support


VNXe Family

User

Virus-checking
server

Write/close or first read after


new virus-definition file
Virus-checking request
Virus-checking signatures

Shared bank of virus-checking


servers
Can deploy multiple vendors
engines concurrently
Virus-checking server only reads
part of files
File access is blocked until it is
checked
Scan after update
Scan on first read
Automatic access-time update

Notification on Virus Detect


Anti-Virus Sizing Tool
Copyright 2011 EMC Corporation. All rights reserved.

Runs over VNX Event Enabler

49

File Level Retention

Copyright 2011 EMC Corporation. All rights reserved.

50

VNXe File Level Retention


Enterprise (FLR-E)
FLR - Enterprise
Name:XYZ Name:XYZ
SSN:1234567890
SSN:1234567890
Account: 808-1287
Account: 808-1287
Name:XYZ
Name:XYZ
Status: Gold
Status:
Gold
SSN:1234567890
SSN:1234567890
Account: 808-1287 Account: 808-1287
Status:
Gold
Status:
Gold
Name:XYZ
Name:XYZ
SSN:1234567890
SSN:1234567890
Account: 808-1287 Account: 808-1287
Status:
Gold
Status: Gold
Name:XYZ
Name:XYZ

Enables adherence to good business


practices
Provides for retention periods per file
Retention is managed on a per-file
basis

SSN:1234567890
SSN:1234567890
Account: 808-1287
Account: 808-1287
Status: Gold
Status: Gold

Copyright 2011 EMC Corporation. All rights reserved.

51

File Level Retention Workflow


FILE LEVEL RETENTION WORKFLOW

Traditional non-FLR files

Append
5
1

Not-locked

Locked files (WORM)


2

Locked
(WORM)

1
2
3
4
5
6

Not-locked files

Expired
3
6

Non-File Level Retention-enabled files


Set retention periodsenable File Level
Retention and commit to WORM state
Retention period extended
Retention period expires
Locked or expired empty files
File deleted

Copyright 2011 EMC Corporation. All rights reserved.

Retention periods are set on a per-file


basis
Retention period is set to infinite if
left unspecified
Cannot be deleted, renamed, or
modified
Retention periods can be extended

Append files
Protected files to which content can
be added but not modified or deleted

Expired files
Files can be deleted after retention
time expires

52

File Level Retention Capabilities


Tamper-proof clock:
Software clock maintained per FLR file system
Maintains an additional clock that is separate from
the system clock
Changes in the system clock time cannot be used to fool the
file into expiration

Used for all File Level Retention time comparisons


File Level Retention clock cannot be modified or
reset

Activity logging:
Log is maintained in the File Level Retention logs
subdirectory
Information for each event:

Copyright 2011 EMC Corporation. All rights reserved.

Time of event (system time)


File with which the event is associated
Action (create, append-only file, etc.)
Operation being performed
The user ID of who performed or attempted the action
53

Backup

Copyright 2011 EMC Corporation. All rights reserved.

54

VNXe Supports Traditional Backup


Software
VNXe
Tape
Librar
y
Contro
l &
Data
Path

Backu
p
Restor
e

Backup
Server

Copyright 2011 EMC Corporation. All rights reserved.

NDMP (Network Data Management


Protocol) Heterogeneous 3-Way
configuration support
Extensive NDMP qualification
performed. Supported Backup
Software Vendors include:

EMC NetWorker
EMC Networker FastStart
CommVault Simpana
Symantec Backup Exec
Symantec NetBackup

55

VNXe Supports EMC Data Domain


Scalable Systems
Reduce storage by an average of 10-30x
and protect up to 28.5 PB
of logical capacity in a single system

High-speed deduplication
Complete backups faster - Throughput of
up to 26.3 TB per hour

Network efficient replication

Deduplication
storage systems

Send only deduplicated and compressed


data across the network, requires a
fraction of the bandwidth, time, and cost
compared to traditional replication
methods

Easy Integration
Qualified with all leading enterprise
backup and archiving applications
integrates easily into existing storage
infrastructures
Copyright 2011 EMC Corporation. All rights reserved.

56

VNXe Supports EMC Avamar

Faster backup over existing LAN/WAN


Data deduplication significantly reduces
backup windows and network traffic by
only storing unique changes, while always
maintaining daily full backups for
immediate single-step restore

Enterprise-wide backup and recovery for


both physical and virtual environments
Optimized for VMware, NAS, Remote Office
and Desktop/Laptop

Flexible deployment

Deduplication
backup software and
system

Copyright 2011 EMC Corporation. All rights reserved.

Avamar Data Store scales to 124 TB of


deduplicated capacity, and integrates with
Data Domain systems for further
scalability of high change rate workloads

High reliability
Patented RAIN technology to provide
uninterrupted data accessibility
57

Windows Integration &


Support

Copyright 2011 EMC Corporation. All rights reserved.

58

VNXe Windows Integration


Quotas (groups and user) Yes, supported through AD only
GPOs Defined & Parsed by AD
Home directories Yes
Windows 2008 AD support Yes
DFS support :
Supports root DFS in standalone mode only
Can be supported as a leaf node
Does not support DFS-R

Support ACLs at the share, level directory and the file Yes via
AD

Copyright 2011 EMC Corporation. All rights reserved.

59

Windows Support Enhancements


Windows Group Policy
Windows Domain
Controller
Domain
Group
Policy
Object

Windows Group Policy


GPOs are defined and
parsed by Active
Directory

VNXe supports GPOs


through Active
Directory

User and
Computers

Copyright 2011 EMC Corporation. All rights reserved.

60

Windows Support Enhancements


Windows 2008 R2 Server

Operating System Refresh

Copyright 2011 EMC Corporation. All rights reserved.

Based on the new Windows 7


kernel
VNXe to support all Windows 2008
R2 server flavors and platforms
Windows 2008 R2 hosts can
connect to the VNXe over CIFS
SMB2, CIFS SMB1, iSCSI
VNXe CIFS servers can be part of a
Windows 2008 R2 based domain
Listing in Microsoft Windows Server
catalog

61

Management

Copyright 2011 EMC Corporation. All rights reserved.

62

Introducing VNXes Unisphere


Click icon to add
picture

Challenge
Graphical, task-oriented
model
Approachable, intuitive design
Web-familiar look & feel

Designed
Designedfor
forIT
IT
Generalist
Generalist

Simplifies management for the storage


novice
Focus
Focuson
on
applications
applications
storage
storageBuilt-in
Built-in
Best
BestPractices
Practices

No storage background required


Immediate productivity

Users can easily:

Online
OnlineSupport
Support
Ecosystem
Ecosystem

Copyright 2011 EMC Corporation. All rights reserved.

Create storage for an application


Monitor and manage that applications
storage
Customize the interface according to
personal preferences or local language
requirements
Identify and resolve hardware failures
Perform software upgrades from interface
63

Application-Enabled Management
Managing storage is
always in the context of
the application
Capacity usage
Storage provisioning

Integrated application best


practices
Automate and simplify
storage provisioning
No guesswork

Best-practice wizards for


key applications

Copyright 2011 EMC Corporation. All rights reserved.

64

Simplified Virtualization Integration


Best Practice Provisioning
Wizard for Hyper-V
Automates storage
provisioning & data
protection
Allows users to monitor
Hyper-V storage on VNXe

API integration with vCenter

nables VMware storage to be fully


managed from VNXe

Copyright 2011 EMC Corporation. All rights reserved.

Discovers existing
datastores and VMs hosted
on VNXe to streamline
provisioning tasks
Allows the VNXe admin to
allocate additional storage
to datastores directly
Automatically creates and
configures the datastore on
ESX after provisioning
65

EMC VSI for VMware vSphere


Unified Storage Management

Storage Admin & VMware


Admin share same visibility
into storage resources
VNX Plug-in allows VMware
admin to Provision VNXe
storage
Create VMFS Datastores
(iSCSI)
Create NFS Datastores
Enables Thin Provisioning

Celerra

Increase storage efficiency while


maintaining operational integrity

NFS data store management for the VMware Administrator


Copyright 2011 EMC Corporation. All rights reserved.

66

Instant Expertise
Best-practice wizards configure storage with just a
few clicks
E-Mail Wizard
Setup hundreds of
Exchange mailboxes
in fewer than 10
clicks

VMware
Setup 1TB VMware
Wizard
datastore in 10
minutes

Share Wizard
Setup NFS and CIFS
shares in minutes

Copyright 2011 EMC Corporation. All rights reserved.

Hyper-V
Setup 1TB Hyper-V
Wizard
datastore in 10
minutes

Volume Wizard
Setup iSCSI volumes
in minutes

67

Built-In Best Practices Examples


Exchange
Calculating the number and size of Exchange storage
groups
Selecting correct storage pool and RAID set for
customer
Calculating the amount of storage for snapshots

VMware
Automatically updating VMware when storage changes
take place
Thin provisioning enabled by default for NFS
datastores
Default snapshot schedule for data protection

Copyright 2011 EMC Corporation. All rights reserved.

68

The VNXe Support


Ecosystem

Copyright 2011 EMC Corporation. All rights reserved.

69

Failed component
Simplified Troubleshooting

easily identified
Alert Notification with
access to remedial
help
Direct access to EMC
support options
Order replacement
part from Unisphere

Copyright 2011 EMC Corporation. All rights reserved.

70

VNXe Health/Alert Drive Failure


CIFS
VNXe

Exchange
I/O

192.168.5.1
\\cifs\myshare
Management
Services
File Services

Block Services

Management
Services
File Services

Block Services

Network, I/O, Service Shims


PCIe SAS

Platform
Services

1
.

Platform
Services

2
.

192.168.5.2
IQN:C0T0L0

NIC

Network, I/O, Service Shims


PCIe SAS

NIC

1.2.Disk
Health/Alert
driver detects
Business
failed
Logic
or removed
detects status
device
Reconstructs data
change
for pending I/O
Marks device
Indicates
as removed
Alert to from
user system
Email Alert to EMC Support & configured email
address

Copyright 2011 EMC Corporation. All rights reserved.

71

The VNXe On-line Support


Experience
Key Benefits
Direct access to product
community
Just a click away

Self-help resources:
Whitepapers, FAQs, online
training, how-to videos
Knowledgebase search

EMC-assisted support
resources:
Live chat
Assisted parts replacement
My support page

EMC-assisted support
resources:
Live chat
Assisted parts replacement
My support page
Copyright 2011 EMC Corporation. All rights reserved.

72

How-To-Videos (Replace Parts)

Copyright 2011 EMC Corporation. All rights reserved.

73

Software Downloads

Copyright 2011 EMC Corporation. All rights reserved.

74

Verify Software Entitlements

Copyright 2011 EMC Corporation. All rights reserved.

75

Update Software

Copyright 2011 EMC Corporation. All rights reserved.

76

Support Forums

Copyright 2011 EMC Corporation. All rights reserved.

77

Check on your Support Contract


with EMC?

Copyright 2011 EMC Corporation. All rights reserved.

78

A Place You Can Always Go

Copyright 2011 EMC Corporation. All rights reserved.

79

Simple. Efficient. Affordable.

Configure in
A
new
seconds
Get
more
way
capacity at
to
less cost
think
Rest
easy,
rock
solid
about
Starting
shared
under $10K

storag
e

Copyright 2011 EMC Corporation. All rights reserved.

80

THANK YOU

Copyright 2011 EMC Corporation. All rights reserved.

81

Você também pode gostar