Você está na página 1de 24

Flexi Multi-radio BTS

Commissioning and Integration


Connect via LMP on ESMx using Ethernet cable
Setup the local IP address on PC under Internet
Protocol (TCP/IP) properties as follow:
IP address:
192.168.255.130
Subnet Mask:
255.255.255.128
Default Gateway: none
Personal Firewall may need to allow access to local
network
e.g. Zone Alarm
The default settings of the BTS are:
IP address: 192.168.255.131
2G Flexi BTS Site Manager connection TCP Port:
27500
2G Flexi BTS Site Manager SW download via TCP
Port: 27501

Local Commissioning
Flexi 2G BTS Site Manager (2/2)

IP address of System Module,


and Password just keep
empty

Local Commissioning
Commissioning Wizard
Select the
Commissioning
Wizard menu item or
click the
Commissioning
button on the View
Selection Bar.

Local Commissioning
Undo Commissioning (1/4)
to revert the site to
uncommissioned
mode and he can
also check the
option that whether
user wants to
erase bypass
capacity along
with it or no.
This button is
disabled in remote
connection

Local Commissioning
Undo Commissioning (2/4)

Local Commissioning
Undo Commissioning (3/4)

Indicate the BTS


has successfully
uncommissioned

Local Commissioning
Commissioning Manually

In this example, user


do commissioning
manually

Local Commissioning
Site Specific Information
Navigation tree
- Enables user to
navigate any
screen, and
update/view
parameters
corresponding to
that screen.
Data persistence
is maintained
across screen
navigations

Local Commissioning
Hardware Configuration
If user has
hardware
template
file (.epb
or SCF
file),
specify
from file
can be
selected
In this
example
specify
manually
is
selected]

Local Commissioning
Hardware Configuration Module
Configuration
configure various
radio modules,
synchronization
master, and radio
masters

Local Commissioning
Hardware Configuration Local
Sector setting
configure
and
associate
antennas of
only one
type of RF
unit (RM) to
a particular
local sector
and specify
per TRX
power

Local Commissioning
Hardware Configuration Antenna
Settings

Select the
antenna line
settings,
specify
MHA
settings,
provide
information
for feeder
voltage,
feeder loss,
VSWR
minor and
major limits
for the
selected
antenna

Local Commissioning
Hardware Configuration RFM
EAC settings
configure the
external
alarm lines
associated
with the
individual
FRMs

Local Commissioning
Transmission Parameter

Enable satellite

Local Commissioning
Transmission Parameter
Synchronization (Source)

Local Commissioning
Transmission Parameter LIF
Setting

Local Commissioning
Transmission Parameter Abis
Termination

Local Commissioning
Transmission Parameter Abis
Allocation

Local Commissioning
Cross Connection Q1
Management

Local Commissioning
SCF preview - Summary
From this
summary, user
can check
whether the
commissioing
step has been
completed.
This can be
checked by
looking at the
indication color
of each step,
green means
ok, red means
not complete

Local Commissioning
Commissioning completeted

Local Commissioning
Tracing the traffic during the test
call
From the toolbar
select Test menu
select Traffic
trace select
cell would be
traced --> click
Automatic Update
(if necessary)
For the CS call,
yellow color
indicates the RTSL
that being
occupied

Sanjaya kumar
Idea cellular Ltd.
Mo.98370897

Você também pode gostar