Você está na página 1de 25

WELL REVIEW

ANALYSIS
BY
RESTU ABDUL HAFIZH

Grid Name : 7S73B


Area
: A07

TEMPERATURE
Trend line stable below 130F,
low temperature
FLUID PERFORMANCE
Fluctuation in the last 2 year
around 5 BFPD but drop to
below 1 BFPD based on the
last test
OIL PERFORMANCE
The same as fluid
performance, oil test drop to
below 1 BOPD based on the
last test
WC PROFILE
Low level WC below 50%
based on the last test

PUMP FILLAGE
Trend line flat below 10%,
last test previous test result

DYNO CARD
Down card show bad
reservoir flow,
PUMP CONDITION overdisplaced, low pump
BUP at 19 Aug 2015 show the fillage
pump
SHORT RECOMMENDATION
is not too bad
Reduce SPM from 9.40 to
8.50
Opportunity for short
If
the
cyclic result
job remains the
same, the pump will be
shut down immediatelly

Grid Name : 3P41C


Area
: A04

TEMPERATURE
Trend line stable at high
level based on the last test
at 20 Aug 2014, no
temperatur data test until
FLUID PERFORMANCE
2016
Trend line stable around 8
BFPD based on the last test

PUMP FILLAGE
Pump Fillage stable in
medium level above 50%
based on the last test at 20
Aug 2014, no test since Aug
2014

OIL PERFORMANCE
Align with fluid decrease,
previously oil performance
was stable, then drop to
around 1 BOPD

WC PROFILE
Medium level WC below 90%
based on the last test

DYNO CARD
PUMP CONDITION
BDJ in May 16 show bad
pump

Down card confirm good


inflow from reservoir, pump
speed has opportunity to
reduce if FOP status is bad,
no test since Aug 2014

SHORT RECOMMENDATION
BDJ Job
Re-Dyno test
Waiting for Re-test

Grid Name : 4J45A


Area
: A10

TEMPERATURE
Trend line stable above 200F

FLUID PERFORMANCE
Fluid was decline below 100
BFPD, then on the last 2 well
test drop to around 20 BFPD

OIL PERFORMANCE
Align with fluid decrease,
previously oil performance
was decline to below 1 BOPD

WC PROFILE
Stable at high level around
95% based on the last test

PUMP FILLAGE
Since Jul 2016, PF stable with
increase to 70% after last
dyno test

DYNO CARD
PUMP CONDITION
Last BUP confirm to bad
pump indication

Down card show good


reservoir flow, FOP status
close to 100%

SHORT RECOMMENDATION
BDJ Job
Acidizing using simple acid

Grid Name : 5R55F


Area
: A02

TEMPERATURE
Trend line flat around 200F,
no test since Jun 2016
FLUID PERFORMANCE
Fluctuation in Sept 2015
above 10 BFPD, then on the
last test drop to 8 BFPD, no
data test since Jun 2016
OIL PERFORMANCE
Oil test increase in Nov 2015
after do BDJ job, then drop to
below 1 BOPD based on the
last test
WC PROFILE
Stable at medium level
around 90% based on the
last test, no test since Jun
2016

PUMP FILLAGE
Since Jan 2016, PF stable
with increase to 45% after
last dyno test

DYNO CARD
PUMP CONDITION
BDJ in Aug 2016 confirm to
good pump

Down card show good


reservoir flow, Pump off
status currently 55%

SHORT RECOMMENDATION
Re-Dyno test
Waiting for Re-test
Acidizing using
simple acid

Grid Name : 6K21A


Area
: A10

TEMPERATURE
Trend line stable below 200F

FLUID PERFORMANCE
Trend line stable around 50
BFPD based on the last test

OIL PERFORMANCE
Oil test decrease since Dec
2015, then stable around 1
BOPD

WC PROFILE
Stable at high level around
95% based on the last test

PUMP FILLAGE
Fluctuation in 4 last test, PF
increase to 90% in May
2016, then drop to 55%
based on the last test

DYNO CARD
PUMP CONDITION
Confirm to good pump

Down card confirm good


inflow from reservoir, pump
of status currently 55%, low
pump slip currently 4%

SHORT RECOMMENDATION
Re-Dyno test
Short Cyclic Job

Grid Name : 3F0207A


Area
: A12

TEMPERATURE
Trend line stable above 200F,
then on July 2016 drop untill
last test to 112F
FLUID PERFORMANCE
Trend line stable above 300
BFPD, then drop to 75 BFPD
based on the last test
OIL PERFORMANCE
Align with fluid decrease,
previously oil performance
was stable above 50 BOPD,
then drop to 2 BOPD based
on the last test
WC PROFILE
Stable at high level above
95% based on the last test

PUMP FILLAGE
Since July 2016, PF
fluctuation below 80%, then
on the last test currently
60%

DYNO CARD
PUMP CONDITION
Confirm to good pump

Surface card confirm good


inflow from reservoir, but
the well no pumping
indication since 5 Aug 2016

SHORT RECOMMENDATION
Short Cyclic Job

Grid Name : 5L27C


Area
: A10

TEMPERATURE
Trend line flat around 200F,
last test previous test result
FLUID PERFORMANCE
Trend line flat around 100
BFPD, then drop to 35%
based on the last test

OIL PERFORMANCE
Trend line stable around 3
BOPD, then drop to below 1
BOPD based on the last test

WC PROFILE
Stable at high level close to
100%

PUMP FILLAGE
Fluctuation in 3 last test, PF
increase to 100% in Apr
2015, then drop to 30%
based on the last test

DYNO CARD
PUMP CONDITION
No BUP and BDJ data test,
cause no well work since
2015

Down card confirm good


inflow from reservoir, but in
normal card show bad flow

SHORT RECOMMENDATION
BDJ job
Reduce SPM from 10.40
to 9.40

Grid Name : 8M38A


Area
: A08

TEMPERATURE
Trend line stable above 200F,
the temperature ever drop in
July 2016 around 100F, then
climb back to the point
FLUID PERFORMANCE
Fluid was decline below 200
BFPD, on the last test
currently around 20 BFPD
OIL PERFORMANCE
Align with fluid decrease,
previously oil performance
was decline to around 1
BOPD
WC PROFILE
Fluctuation at medium level
below 95%, on the last test
currently 94%

PUMP FILLAGE
Trend line stable around 45%
based on the last test

DYNO CARD
PUMP CONDITION
Confirm to good pump

Surface card confirm good


inflow from reservoir, but
the card show low pump
fillage

SHORT RECOMMENDATION
Short Cyclic Job