Unidades y poderes calorficos
Table 1-1
Energy Units and Energy Content of Fuels
1 kWh 3412 Btu
1 ft 3 natural gas 1000 Btu
1 Ccf natural gas 100 ft 3 natural gas
1 Mcf natural gas 1000 ft 3 natural gas
1 therm natural gas 100,000 Btu
1 barrel crude oil 5,100,000 Btu
1 ton coal 25,000,000 Btu
1 gallon gasoline 125,000 Btu
1 gallon #2 fuel oil 140,000 Btu
1 gallon LP gas 95,000 Btu
1 cord of wood 30,000,000 Btu
1 MBtu 1000 Btu
1 MMBtu 10 6 Btu
1 Quad 10 15 Btu
1 MWh 10 6 vatios hora
Poder calorfico superior y consumo
de combustibles en Mxico

Consumo de combustibles Poder calorfico


Sep-02/Ago-03 superior
Combustible MBtu =106Btu HHV Unidades
6 3
Combustleo 679,789,985 39.76 10 Btu / m
6 3
Gas natural 476,634,022 36.68 10 Btu / mil m
6 3
Diesel 29,097,076 35.31 10 Btu / m
6
Carbn* 259,686,776 20.20 10 Btu / ton
Total 1,445,207,859

Consumo de combustibles para generacin elctrica.


Con informacin del 3er Informe de Labores CFE.

Tercer informe de labores CFE: http://www.cfe.gob.mx/NR/rdonlyres/1975FDA2-99EC-488B-BA80-A2A52E007F7F/0/INFLAB20022003CFE.pdf


Razones para administrar la
energa
Reducir los efectos nocivos al
ambiente, como: lluvia cida,
calentamiento global, degradamiento
de la capa de ozono etc
Ayudar a una seguridad energtica.
Mejorar la competitividad.

Capehart, Turner, Kennedy. Guide to energy management. Cuarta edicin


Panorama Gas Natural
0.5
2.6

4.4 0.7

0.9 1.9
0.5
1.5

1.1
1.0

Regiones
Precio relativo de gas productoras
natural Chile = 1.0
Fuente: SRI, 2000, Plantas Industriales, World Gas Intelligence.
Precios recientes del gas
natural
pesos/kWh

0.40
0.50
0.60
0.70
0.80
Ene-00
May-00
0.47
Sep-00
Ene-01
May-01
Sep-01

Ene-02

May-02
Factor de carga = 0.6

Sep-02
Ene-03
May-03

Sep-03

Ene-04
0.74
Panorama tarifas elctricas
Definicin Admon. de la energa
The judicious and effective use of
energy to maximize profits (minimize
costs) and enhance competitive
positions.
El uso razonable y efectivo de la
energa para maximizar la utilidad
(minimizar costo) y mejorar la
posicin competitiva
Capehart, Turner, Kennedy. Guide to energy management.
Cuarta edicin
Objetivos especficos
Mejorar la eficiencia energtica y reducir el uso de
energa, reduciendo adems los costos de la energa
Lograr buena comunicacin en aspectos de la energa
Desarrollar y mantener mediciones, reportes y
estrategias de administracin efectivas para lograr un
uso efectivo de la energa
Encontrar nuevas y mejores maneras de aumentar los
retornos de las inversiones en energa a travs de
investigacin y desarrollo
Desarrollar el inters y dedicacin en la
administarcin de la energa en todos los empleados
Reducir el impacto de las interrupciones en el
suministro
Capehart, Turner, Kennedy. Guide to energy management. Cuarta edicin
Fuente de nueva energa
In fact, energy available from energy
management activities has almost always
proven to be the most economical source of
new energy

Capehart, Turner, Kennedy. Guide to energy management. Cuarta edicin

La energa proveniente de actividades de


administracin de la energa ha probado ser
la fuente ms econmica de nueva
energa.
Fuente de nueva energa
Las actividades de administracin de
energa son ms amigables con el
ambiente que la produccin en gran
escala de energa y consumen menos
recursos.
Capehart, Turner, Kennedy. Guide to energy management. Cuarta edicin
Energy audit
An energy audit serves the purpose of
identifying where a building or plant
facility uses energy and identifies
energy conservation opportunities

Albert Thumann. Plant engineers and managers guide to energy


conservation. Octava edicin
Caractersticas de los primeros
proyectos
Rapid payback
High probability of success (risk
assesment)
Few negative consequences.
Capehart, Turner, Kennedy. Guide to energy management. Cuarta edicin
Asignacin de costos de energa
Es muy difcil reducir los costos de
energa en una instalacin en donde
no hay manera de asignar
directamente los costos de la misma.
Los costos de energa se deben cargar a
los centros de produccin de la
misma manera que se hace con los
materiales y la mano de obra.
Sistema de monitoreo
No puede controlar un proceso que no
es medido y no puede administrarse
un proceso que no es controlado
One cant control a process that is not
measured, and cant manage a
process that is not controlled
W. E. Deming.
reas de oportunidad tpicas
Iluminacin
Aire acondicionado
Bombeo
Cogeneracin
Peak shaving y Facturacin*
Load shifting
Correccin de factor de potencia
Aislamiento trmico
Eficiencia y balance de energa
El

Ein Eout
Equipo de conversin de
energa con eficiencia

La energa de salida es igual a la energa de entrada por la eficiencia


y la energa de entrada es la de salida ms la de prdidas:

Eout Ein Ein Eout El


Eficiencia y costo unitario
El

Ein , GJ Eout , GJ
Equipo de conversin
de energa con
eficiencia
X ,$ X ,$

El importe pagado por la energa es el mismo a la entrada que a la salida. No se ve


afectado por la eficiencia. Qu ocurre con el costo unitario? Es el mismo a la salida que
a la entrada?
$ X ,$ $ X ,$ 1 X ,$ 1 $
CUEin , CUEout , CUEin ,
GJ Ein ,GJ GJ Eout ,GJ Ein ,GJ GJ
El costo unitario de salida es el costo unitario de entrada entre la eficiencia. Una
eficiencia baja hace que el costo unitario de la energa de salida (til) aumente.

Você também pode gostar