FIRE SAFETY

PREVENTION AND PROTECTION


What is Fire?
Fire is one of the leading causes of Accidental
death.
Fire is the heat or burning that destroy things,
lives or properties.
Fire is a great warmth feeling towards the
opposite sex, it is excitement
Fire is a result from fast chemical reaction
between a combustible substance and oxygen,
accompanied by generation of heat
Causes of Fire
Fire Code Provisions
Early Detection and Warning
Fire and Emergency Exits
Emergency Lights and Directional Signs
Fire Suppression System
Fire Extinguishers
Early Detection and Warning
To notify occupants of the facility to take
evasive action to escape the dangers of fire

To initiate the automatic fire control and


suppression system

To summon the Fire Brigade


Early Detection and Warning
Heat Detectors
Smoke Detectors

Automatic Fire Alarms


Fire and Emergency Exits
Alternate Evacuation Routes & Options

Flame and Smoke Free, Fire-rated Stairwells


Emergency Lights and Directional Signs
Fire Exit Signs
Directional Signs
Illuminated and Luminous Fire Exit Signs
Emergency Lights
Fire Suppression System
Sprinkler System
To prevent fire spread upwards in multiple storey
building and to other part of the building
Fire Suppression System
Pre action system
Deluge system
ACAF system
Clean Agent Fire Suppression System
Double interlock Pre-action sprinkler
system
Network relay and communication room
Coal handling complex
Linear heat detection system for
Deluge valve system
Coal Unloading Pier, No. 1 Belt Conveyor & No. 1 Transfer Tower,
No. 2B Belt Conveyor, No. 1 Sampling House & No. 2B Transfer
Tower
No. 2A Conveyor Gallery & No. 2A Transfer Tower,
No. 3A Belt Conveyor & Driving House for No. 2A Transfer Tower,
No. 4A & 4B Belt Conveyor, Tall House for No. 4A & 4B Belt
Conveyor & No. 3 Transfer Tower,
Nos. 5A & 5B Belt Conveyors & Crusher House,
Nos. 6A/6B Belt Conveyors, Crusher House, No. 2 Metal Removal
House & Bunker Bay Transfer Tower,
No. 7A & 7B Belt Conveyors
Linear heat detection system for
Deluge valve system
Deluge System employs water spay nozzle
attached to a piping system installed in the Belt
Conveyor Areas
In a Deluge Water Spray System, one event
caused by a fire condition, must occur:
Operation of a Fire Detection device( Linear Heat
Detector, Fixed Temperature Heat Detector or Pull
Station)
The solenoid valve actuator must be energize by
releasing panel upon the operation of the fire
detection device
Components of Deluge Water Spray
System
Deluge Valve
Solenoid Valve
Alarm Line Linear Heat Detector
Addressable Alarm Line Module
Fixed Temperature Heat Detector
Alarm Line Linear Heat Detection System
Manual Pull Station
Emergency Release (Cabinet)
Fire Alarm Bell
Horn and Flashing Strobe
Water Motor Alarm Gong
NOVEC 1230 Clean Agent Fire
Suppression System
NOVEC 1230 fluid is a low global warming potential Halon
replacement for use as a gaseous fire suppression agent
It is generally used in situation where water from a fire sprinkler
would damage expensive equipment or where water-based fire
protection is impractical.
NOVEC 1230 is a colorless, non-toxic gas perfectly suited to protect
high vale assets in the area that may be normally occupied, in
locations where clean-up of other agents is problematic, when
storage space for a fire suppression agent is restricted, or when an
electrically non-conductive agent is required
NOVEC 1230 is clean, leaves no residue, thereby eliminate costly
after-fire clean-up, and keeping expensive down-time to minimum
Components of NOVEC 1230 Clean
Agent Fire Suppression System
NOVEC 1230 Cylinder/ Valve Assembly 6M
Discharge Nozzle
Electric Control Head
Smoke Detectors
Suppression Control Panel
Notification Devices
Manual Pull Station
Abort Station
Double Interlock Pre-Action Sprinkler
System
What to do During FIRE ALARM
On Hearing the alarm
1. All personnel shall cease work, be alert,
and scout around for any visible sign of FIRE
2. Have the Fire Extinguisher accessible
and readily use
3. At the protected area, the Authorized
Personnel shall check whether there is a FIRE or
FALSE ALARM
What to do ON FIRE
When the Fire becomes uncontrollable, the
Authorized Personnel must:
Have the Fire Extinguisher ready for protection
Ensure all personnel has safely vacated the area
upon his/her leaving shall close all doors behind
Pull down the manual release station to by pass
automatic detection operation