What is Fire? Fire is one of the leading causes of Accidental death. Fire is the heat or burning that destroy things, lives or properties. Fire is a great warmth feeling towards the opposite sex, it is excitement Fire is a result from fast chemical reaction between a combustible substance and oxygen, accompanied by generation of heat Causes of Fire Fire Code Provisions Early Detection and Warning Fire and Emergency Exits Emergency Lights and Directional Signs Fire Suppression System Fire Extinguishers Early Detection and Warning To notify occupants of the facility to take evasive action to escape the dangers of fire
To initiate the automatic fire control and
suppression system
To summon the Fire Brigade
Early Detection and Warning Heat Detectors Smoke Detectors
Automatic Fire Alarms
Fire and Emergency Exits Alternate Evacuation Routes & Options
Flame and Smoke Free, Fire-rated Stairwells
Emergency Lights and Directional Signs Fire Exit Signs Directional Signs Illuminated and Luminous Fire Exit Signs Emergency Lights Fire Suppression System Sprinkler System To prevent fire spread upwards in multiple storey building and to other part of the building Fire Suppression System Pre action system Deluge system ACAF system Clean Agent Fire Suppression System Double interlock Pre-action sprinkler system Network relay and communication room Coal handling complex Linear heat detection system for Deluge valve system Coal Unloading Pier, No. 1 Belt Conveyor & No. 1 Transfer Tower, No. 2B Belt Conveyor, No. 1 Sampling House & No. 2B Transfer Tower No. 2A Conveyor Gallery & No. 2A Transfer Tower, No. 3A Belt Conveyor & Driving House for No. 2A Transfer Tower, No. 4A & 4B Belt Conveyor, Tall House for No. 4A & 4B Belt Conveyor & No. 3 Transfer Tower, Nos. 5A & 5B Belt Conveyors & Crusher House, Nos. 6A/6B Belt Conveyors, Crusher House, No. 2 Metal Removal House & Bunker Bay Transfer Tower, No. 7A & 7B Belt Conveyors Linear heat detection system for Deluge valve system Deluge System employs water spay nozzle attached to a piping system installed in the Belt Conveyor Areas In a Deluge Water Spray System, one event caused by a fire condition, must occur: Operation of a Fire Detection device( Linear Heat Detector, Fixed Temperature Heat Detector or Pull Station) The solenoid valve actuator must be energize by releasing panel upon the operation of the fire detection device Components of Deluge Water Spray System Deluge Valve Solenoid Valve Alarm Line Linear Heat Detector Addressable Alarm Line Module Fixed Temperature Heat Detector Alarm Line Linear Heat Detection System Manual Pull Station Emergency Release (Cabinet) Fire Alarm Bell Horn and Flashing Strobe Water Motor Alarm Gong NOVEC 1230 Clean Agent Fire Suppression System NOVEC 1230 fluid is a low global warming potential Halon replacement for use as a gaseous fire suppression agent It is generally used in situation where water from a fire sprinkler would damage expensive equipment or where water-based fire protection is impractical. NOVEC 1230 is a colorless, non-toxic gas perfectly suited to protect high vale assets in the area that may be normally occupied, in locations where clean-up of other agents is problematic, when storage space for a fire suppression agent is restricted, or when an electrically non-conductive agent is required NOVEC 1230 is clean, leaves no residue, thereby eliminate costly after-fire clean-up, and keeping expensive down-time to minimum Components of NOVEC 1230 Clean Agent Fire Suppression System NOVEC 1230 Cylinder/ Valve Assembly 6M Discharge Nozzle Electric Control Head Smoke Detectors Suppression Control Panel Notification Devices Manual Pull Station Abort Station Double Interlock Pre-Action Sprinkler System What to do During FIRE ALARM On Hearing the alarm 1. All personnel shall cease work, be alert, and scout around for any visible sign of FIRE 2. Have the Fire Extinguisher accessible and readily use 3. At the protected area, the Authorized Personnel shall check whether there is a FIRE or FALSE ALARM What to do ON FIRE When the Fire becomes uncontrollable, the Authorized Personnel must: Have the Fire Extinguisher ready for protection Ensure all personnel has safely vacated the area upon his/her leaving shall close all doors behind Pull down the manual release station to by pass automatic detection operation