SIEMENS

Process device manager


SIMATIC PDM is the manager of all
process devices in a plant
Management of field devices includes
functions such as:
Access to all parameters of a
process device
Access to all maintenance and
diagnostic information of a process
device
Archiving of all parameters (except
calibration parameters),
maintenance
and diagnostic information in one
consistent data base
Documentation
Comparison of parameters sets
Display of process variables and
status of a process device
Support of loop checks via
simulation of process variables of a
process device
SIEMENS
Process instrumentation 3/1 6 September 2017
SIEMENS LTD EGYPT 2007
All Rights Reserved
SIEMENS

Process device manager


There used to be one SIPROM
software package per process
device in the past.
The introduction of PROFIBUS could
have led to the duplication of the
SIPROM packages. New versions of
WINDOWS and faster PCs require
modification of software. This
scenario did not make any economic
sense.
SIMATIC PDM can talk 5 languages,
English, French,German, Italian and
Spanish.
The target for SIMATIC PDM is to be
the one and only manager of the
process devices in a plant.
The majority of customers like this
approach.
The use of SIMATIC PDM requires
authorisations.
SIMATIC PDM is today the most powerful
Process Device Manager on the market

SIEMENS
Process instrumentation 4/1 6 September 2017
SIEMENS LTD EGYPT 2007
All Rights Reserved
SIEMENS

Process device manager


communication
PC with SIMATIC PDM

Serial HART via serial


Interface
interface or USB
(COM- Ports)
or USB and HART-Modem.
Proprietary protocol
HART Modem of SIPART DR via
serial interface

Power
Proprietary protocol
4 to 20 of SIREC via serial
mA interface
SIPART DR19 SIREC L / LA
SIPART DR20 SIREC P / PA
SIPART DR21 SIREC PU
SIPART DR22

SIEMENS
Process instrumentation 5/1 6 September 2017
SIEMENS LTD EGYPT 2007
All Rights Reserved
SIEMENS

Process device manager


communication PROFIBUS DP via
Communication
PC with SIMATIC PDM Processor in PC.
Communication with
Class 1 Class 2 Master devices with
Master Acyclic Master PROFIBUS PA is
Cyclic always via
Master Communication Processor PROFIBUS DP and
for PROFIBUS, e.g. CP5611 DP/PA-Link or
DP/PA-Coupler.

PROFIBUS DP
HART via
PROFIBUS DP,
Remote I/O
ET200M Remote I/O
ET 200 M DP/PA-Link with HART-Modules.
with HART PROFIBUS PA
The ET200 is
AI or AO currently the only
Motor Remote I/O that
4 to 20 mA provides this feature.
Standardisation of
this feature is in
progress within the
PROFIBUS Trade
Organisation.
SIEMENS
Process instrumentation 6/1 6 September 2017
SIEMENS LTD EGYPT 2007
All Rights Reserved
SIEMENS

Process device manager


communication
HART Multiplexer via OPC
Server of the HART
PC with SIMATIC PDM Communication
Class 2 Master Foundation. Multiplexers
Acyclic Master from the following
companies are
Serial Interface integrated:
COM1 or COM2 Stahl
PROFIBUS DP
(RS232) Peppers&Fuchs
Elcon
RS232 to
RS485
MTL
Service Bus
converter Teach-in function of OPC
Server (automatic project
HART Multiplexer generation)

4 to 20 mA

SIEMENS
Process instrumentation 7/1 6 September 2017
SIEMENS LTD EGYPT 2007
All Rights Reserved
SIEMENS

Process device manager


connection points

Engineering Operator Systembus


Station Station
Industrial Ethernet / Fast Ethernet

Possible
.... .... ....
PROFIBUS DP
connecting point 45.45 kBit/s S7-400 S7-400
of SIMATIC PDM
DP/PA-Coupler
PROFIBUS-PA
PROFIBUS DP 12 MBit/s

SIMOCODE Remote I/O SIPART HART-Multiplexer


Motor ET 200M DR
Management with HART- Controller
DP/PA-Link modules
PROFIBUS PA

Service
Bus

SIEMENS
Process instrumentation 8/1 6 September 2017
SIEMENS LTD EGYPT 2007
All Rights Reserved
SIEMENS

Process device manager


connection points
PC with Integration of process devices
SIMATIC PDM into SIMATIC PDM is via a
Device Description (DD) Manage devices catalog that
copies Device Descriptions to
the relevant directories. This
principle opens SIMATIC PDM
for all manufacturers.
Device Descriptions (DDs) are
ASCII files that describe all
parameters of the process
device. The language of the
DDs is based upon the HART
DDs.
The language of the DDs for
SIMATIC PDM is a standard of
PROFIBUS International

SIEMENS
Process instrumentation 9/1 6 September 2017
SIEMENS LTD EGYPT 2007
All Rights Reserved
SIEMENS

Manage device catalogue

In this dialog box you can


import or reassign devices.
New device types are
displayed in bold type.
If at least one device, but not
all devices, within a group are
selected, this selection field
will have a grey background.

SIEMENS
Process instrumentation 10/1 6 September 2017
SIEMENS LTD EGYPT 2007
All Rights Reserved
SIEMENS

Manage device catalogue

The optimum is to have a DD


designed for SIMATIC PDM.
Alternatives are as follows:
PROFIBUS PA: Integration
via PROFILE 3 DDs
HART: Integration as generic
device (works always, but
limited of parameters)
Integration via HART DDs
(this is an unique feature of
SIMATIC PDM)
DD-Library of the HART
Communication Foundation is
integrated as standard. This
library contains hundreds of
DDs. There is currently no
other tool on that market that
includes the HCF library.

SIEMENS
Process instrumentation 11/1 6 September 2017
SIEMENS LTD EGYPT 2007
All Rights Reserved
SIEMENS

Process device manager


Configuration

The Process Device Plant


View shows all process
devices of a plant
independent from their
communication method
and how they are
networked.
Representation of the
process devices is via
their TAG.
SIMATIC PDM opens a
process device via a
double click of the mouse
on the TAG.

SIEMENS
Process instrumentation 12/1 6 September 2017
SIEMENS LTD EGYPT 2007
All Rights Reserved
SIEMENS

Process device manager


Configuration

Device Identification

With SIMATIC PDM LifeList you can scan DP and PA chains and determine what
HART devices are connected to a HART Modem.
You can specify whether the scan process is run once or in cycles and whether
subnets should also be scanned.
You can change the addresses and TAGs for devices directly in the LifeList, and
you can apply these changes to existing projects.
SIMATIC PDM LifeList support XML export of LifeList data.
SIEMENS
Process instrumentation 13/1 6 September 2017
SIEMENS LTD EGYPT 2007
All Rights Reserved
SIEMENS

Process device manager


Configuration
Diagnostic information

Detail Diagnostic

Standard diagnostic information


Detail diagnostic over EDD (Electronic Device Description)
Column selection

SIEMENS
Process instrumentation 14/1 6 September 2017
SIEMENS LTD EGYPT 2007
All Rights Reserved
SIEMENS

Process device manager


Configuration

The SIMATIC Hardware


Configurator is a part of the
SIMATIC Manager.
The Hardware Configurator is
not available in the stand alone
version of SIMATIC PDM.
The Hardware Configurator
configures the hardware of all
SIMATIC S7 PLCs and
SIMATIC PCS7 Controllers
including field devices and
Remote I/Os the SIMATIC
Controllers communicate with.

SIEMENS
Process instrumentation 15/1 6 September 2017
SIEMENS LTD EGYPT 2007
All Rights Reserved
SIEMENS

Process device manager


Configuration

The SIMATIC Hardware


Configurator is an application
for the SIMATIC Manager
Representation of the process
devices is via their TAG and an
icon
SIMATIC PDM opens a process
device via a double click of the
mouse on the TAG/icon
Insertion of an additional
process device inserts this new
device automatically in the
Process Device Plant View

SIEMENS
Process instrumentation 16/1 6 September 2017
SIEMENS LTD EGYPT 2007
All Rights Reserved
SIEMENS

PDM SW interface

Uniform Human
Machine Interface
provides ease of use
Capable of
communicating all
parameters of a field
device
Parameter groups of
field device
(e.g. SITRANS T3K)
coloured marking
of changed
parameters

white read / write parameters

grey read only


parameters

Online display of

SIEMENS
process variables

Process instrumentation 17/1 6 September 2017


SIEMENS LTD EGYPT 2007
All Rights Reserved
SIEMENS

PDM SW interface
Additional functions such as
set address of process
device (PROFIBUS)
measured value display
online
trend display
comparison of parameter
sets
simulation of process
variables
display device status
Parameter groups of parameter reset
field device
(e.g. SITRANS T3K)
calibration of process
coloured
devicemarking
of changed
parameters

white read / write parameters

grey read only


parameters

Online display of
process variables
SIEMENS
Process instrumentation 18/1 6 September 2017
SIEMENS LTD EGYPT 2007
All Rights Reserved
SIEMENS

PDM SW Graphics

Graphic capabilities are


available.
Access to the graphic
capabilities is via the DD
Zooming of time and
process variable is
possible
SIMATIC PDM collects
process variables for
graphic representation
only while the graphic
window is open.

SIEMENS
Process instrumentation 19/1 6 September 2017
SIEMENS LTD EGYPT 2007
All Rights Reserved
SIEMENS

PDM Operating systems

Microsoft Windows 2000


Professional
Microsoft Windows XP
Professional

SIEMENS
Process instrumentation 20/1 6 September 2017
SIEMENS LTD EGYPT 2007
All Rights Reserved
SIEMENS

Questions?

SIEMENS
Process instrumentation 21/1 6 September 2017
SIEMENS LTD EGYPT 2007
All Rights Reserved

Você também pode gostar