GRIHA RATING

HOSPITAL DESIGN
PROJECT DETAILS

SITE LOCATION : RANCHI


SITE AREA : 10ACRES
CLIMATE : COMPOSITE
BUILDING TYPE : HOSPITAL
PARAMETERS CONSIDERED

• Roof insulated with vermiculite concrete


and china mosaic white finish.
• Insulated walls using expanded
polystyrene insulation.
• Shading devices and fenestration have
been designed to cut off summer sun &
let in winter sun.
• Glare free day lights used through specially
designed skylights.
• Building designed as such wind direction
can be redirected.
• Deciduous trees used in the south to shade
the building in summers ,in winters these
shed their leaves thus letting in winter sun
GRIHA RATING ANALYSIS

S.NO GRIHA RATING PARAMETERS APPRAISAL MAXIMUM POINTS


POINTS ATTEMPTED

1. SITE SELECTION 1 1

2. TO PRESERVE AND PROTECT NO EXISTING LANDSCAPE CONSIDERED 5 -


EXISTING LANDSCAPE
3. SOIL CONSERVATION(POST WILL BE CONSIDERED 4 4
CONST.)
4. DESIGN TO INCLUDE EXISTING NO EXISTING SITE FEATURES 2 -
SITE FEATURES
5. REDUCE HARD PAVING ON SITE CONSIDERED 2 2

6. OUTDOOR LIGHTING SYSTEM CONSIDERED 3 3


FACILITY
7. PLANNED UTILITIES EFFICIENTLY CONSIDERED 3 3
AND OPTIMIZE ON SITE
SELECTION
S.NO GRIHA RATING PARAMETERS APPRAISAL MAXIMUM POINTS
POINTS ATTEMPTED

8. MINIMUM LEVEL OF WILL BE CONSIDERED 2 2


SANITATION,SAFETY FACILITIES
FOR CONST. WORKERS
9. REDUCE AIR POLLUTION DURING WILL BE CONSIDERED 2 2
CONST.
10. REDUCE LANDSCAPE WATER ROOT ZONE SYSTEM,WATER HARVESTING 3 3
REQUIREMENT
11. REDUCE BUILDING WATER USE SENSORY TAPS,GREY WATER REUSE 2 2

12. EFFICIENT WATER USE DURING WILL BE CONSIDERED 1 1


BUILDING CONST.
13. OPTIMIZATION OF BUILDING INCORPORATION OF NATURAL LIGHTING 6 6
DESIGN TO REDUCE AND VENTILATION
CONVENTIONAL ENERGY
DEMAND
14. OPTIMIZATION OF ENERGY 12 12
PERFORMANCE OF BUILDING
WITHIN SPECIFIC COMFORT
S.NO GRIHA RATING PARAMETERS APPRAISAL MAXIMUM POINTS
POINTS ATTEMPTED

15. UTILIZATION OF FLYASH IN NOT CONSIDERED 6 -


BUILDING STRUCTURE
16. REDUCE VOLUME,WEIGHT AND WILL BE CONSIDERED 4 4
TIME OF CONSTRUCTION BY
ADOPTING EFFICIENT
TECHNOLOGY
17. USE LOW ENERGY MATERIAL FOR 4 4
INTERIORS
18. RENEWABLE ENERGY SOLAR ENERGY,RAIN WATER HARVESTING 5 5
UTILIZATION
19. RENEWABLE ENERGY BASED HOT SOLAR WATER HEATERS INSTALLED 3 3
WATER SYSTEM
20. WASTE WATER TREATMENT SEWAGE TREATMENT PLANT 2 2

21. WATER RECYCLE AND REUSE REUSE OF GREY WATER FOR OTHER 5 5
PURPOSES
S.NO GRIHA RATING PARAMETERS APPRAISAL MAXIMUM POINTS
POINTS ATTEMPTED

22. REDUCTION OF WASTE DURING WILL BE CONSIDERED 2 2


CONSTRUCTION
23. EFFICIENT WASTE SEGREGATION SEPARATE BIO MEDICAL WASTE 2 2
TREATMENT PLANT
24. STORAGE AND DISPOSAL OF CONSIDERED 2 2
WASTE
25. RESOURCE RECOVERY FROM NOT CONSIDERED 2 -
WASTE
26. USE OF LOW VOC PAINT CONSIDERED FOR INTERIORS 4 4
ADHESIVE
27. MINIMIZE OZONE DEPLEATING 3 -
SUBSTANCES
28. ENSURING WATER QUALITY PURIFICATION PLANT 2 2
S.NO GRIHA RATING PARAMETERS APPRAISAL MAXIMUM POINTS
POINTS ATTEMPTED

29. ACCEPTABLE OUTDOOR AND BUFFER ZONES CREATED USING 2 2


INDOOR NOISE LEVEL PLANTATION AND NOISE INSULATING
MATERIALS USED IN INTERIORS
30. TOBACCO AND SMOKE CONTROL CONSIDERED 1 1

31. UNIVERSAL ACCESIBILITY RAMPS AND LIFTS CONSIDERED ALONG 1 1


WITH UNIVERSAL ACCESIBLE TOILETS
32. OPERATION AND MAINTAINANCE WILL BE CONSIDERED 2 2
PROTOCOL
33. INNOVATION 4

34. ENERGY AUDIT AND VALIDATION WILL BE DONE


OF THE WHOLE BUILDING
TOTAL CREDITS 100 82
ECOTECT ANALYSIS

LOCATION – NEW DELHI


PROJECT TYPE- RESIDENCE

SHADOW RANGE SUNPATH DIAGRAM

SOLAR EXPOSURE THERMAL ANALYSIS WIND ANALYSIS


PREVAILING WIND PSYCHROMETRIC CHART

Você também pode gostar