Você está na página 1de 40

DRG International

Inc.
Nov 4, 2014
ElizaMat ®
makes all this possible…

The ElizaMat-C2 performs automated Chemistry and ELISA

ElizaMat-CL performs automated ELISA and CLIA on one the


same plate

User-programmable open system allows


Customers the capability to utilize a wide range of CLIA, ELISA and
Chemistry assays
World wide ElizaMat
distributors have placed
the analyzer’s for a
variety of applications:

 Clinical Laboratory
 Research – University Life
Sciences
 Wine Analysis
 Food & Grain Safety
 Water Quality
 Animal Safety
ElizaMat ®
makes all this possible…

Microwells for all reactions CLIA, ELISA & Chemistry


Using Standard 96 Well Coated Plates or 8 Well Strips
ElizaMat C2 ®

• performs EIA and/or Biochemistry assays


• includes plate washing system
• fabricated-style enclosure with roll-up shield

Chemistry
200 tests per hour endpoint, or 170 per hour if all kinetic
assays

ElizaMat CL – CLIA & ELISA


15 minutes to load a 96 well plate with samples and
reagents washing the probe between each sample
(actual throughput depends upon incubation times)
ELISA Assays
 When performing EIAs: ElizaMat schedules EIA tests to
process by assays in strips.
 You can place a different assay in each row as long as they
share a common rack, and incubation temperature. Max. 12
assays per plate. Max. 2 wash buffers. The timing for the
different assays can be different.
 ElizaMat organizes the assay start times to prevent timing
conflicts
ElizaMat Optical Design
• 4 optical channels align
with 4 micro-wells
• Each well is read at all 8
wavelengths (340-
750nm)
• Absorbance
• Cut- Off
• Factor
• Cut –Off Standard
• Standard
• Dose Response
• Point to Point • Polynomials of different
• Linear Regression orders
• Cubic Spline (Constrained)
• % Absorbance
ElizaMat ®

Open system
Liquid Auto-
Windows software
sensing Precision
probe optical system
2 syringe pumps

wash head
wash, rinse,
and waste
bottles
(not shown)

Wash features are


not included in the
Chemistry-only
Model 2902

DI water reagents samples Reactions


Max height =100mm

Standard Reagent & Sample racks are shown here,

Reagent racks may remain loaded for routine panels and removed for refrigeration.
 Probe tip detects liquid
Liquid Handling surface
ElizaMat  ElizaMat estimates
automatically selects remaining volume.
one of its 2 syringe
 Probe washes
pumps,
automatically after each
50uL or 2.5mL
use
for pipetting and
diluting  Wash protocols are
programmable, to
prevent carryover.

SAMPLE-REAGENT PROBE:
* Reagent Volume inventory sensing
* Temperature controlled
* Retractable – crash protection
* Easy to replace probe
Cooling unit attaches to ElizaMat ®

Reagents go in
Insulated rack

Rack slides on
cooling tracks
• Fluid Handling - Precise Pipetting sample
volume as low as <2 uL (2uL to 1.95 mL)
• On-board pre-dilution & reflex testing

• No Carry-over with unique wash system


• Incorporated incubation system & plate mixer
with plate Washer System
• Reads four channels with eight filters with a
range of 340-700nm
The ElizaMat Software features allows:
• Pausing the instrument to add sample or reagent,
option of canceling commands
• Customizable test profiles and panels for specific
test needs
• Language Selection file
• Lock out for Assay Editor program
• Data Storage – unlimited capacity
• ElizaMat Manager – easy to use for calibration, QC,
sample management and results reporting
• ElizaMat Manager is used to run all the
functions on the analyzer
• Provides user access to the run ElizaMat for
sampling and reports in the lab.
• System is connected to a PC with a program
that is easy to operate and works with
Windows Operating System.

• LIS Connectivity for the Laboratory


 AssayEditor Software used for Assay
Programming
 Sample Bio-chemistry programs are already
available in the software. These can be used or
make a copy and put changes into the copy.
 Customers program their EIA kits
 Technicalsupport is available to all customers
for technical needs
TABS
Layout, Calibration, Sample, Test List, Report
Quality
Control
Tracking

LIS compatible.
Internet service
and upgrades
…and more
 Selfmonitoring software and error messages
 Continuous communication logging between
Data Manager and the ElizaMat instrument
 Automatic utility that makes attachments for
emailing - test programs and error codes
 Automatic tests for filter voltage, pressure, and
many other parameters accessible to service
technician
 LEDs and other hardware and software
indicators for tools-free diagnostics
 Software upgrades from website
Patented optical system uses
PMT (photomultiplier) to detect
light signals from Luminescence
and from 4 standard wavelengths
for Absorbance.

The patented scan head prevents


cross talk. You can program a
wide range of CLIA assays and
standard ELISA tests.
 Fullyautomated
 Single Plate - Open system
 Processes ELISA and CLIA
assays
Processes
both, ELISA
and CLIA in a
single plate!
Patented dual-function
reader, automatically
switches between
absorbance and
luminescence
Intelligent software
coordinates and optimizes
the timing of all assays
 Software with identical look
and feel
 Plate Mixing
 Incubation
 Single Sample/Reagent
probe
 Single reader
 Reads RLUs (Relative Light
Units) and absorbance
 Eight-channel optic fiber
bundle
Patented dual-function reader,
automatically switches between
absorbance and luminescence
User friendly SW for sample
processing samples and training
for new operators
Automatically process
ELISA and CLIA in the same
plate in the same run
The software automatically
manages each assay
separately so that multiple
assays can be processed on
the same plate even if they
have different timings,
reagents and reading modes
 Easy to operate
 High-precision pipetting
 Software prevents timing conflicts
 Complete QC package
 Adapt DRG reagents for application
 Consolidate two instruments in one
 No proprietary consumables
 Compact footprint saves bench space
 Robust design
 No disposable tips needed
 Password security
 Patient database software included
 Unlimited number of customized
protocols
 LIS integration
 Flexible reporting styles
 Self-monitoring of performance
 Simple, economical maintenance
 Built-in safety features
 Long-life IAD filters
 ISO13485, CE Marked, FDA