Sailor Power Supply Units The most important thing we build is trust
Products
Part No. Product Description
406080A-00500 SAILOR 6280 AC/DC Power Supply Unit
Accessories
Part No. Product Description
406080A-001 Wall-mount Tray, heavy duty, with cable-relief
bracket for SAILOR 6080 AC/DC Power Supply
406080A-opt.002 4 mounting bolts for mounting 2 AC/DC Power Supply units, M6X100
mm, DIN912 Unbrako
406080A-opt.003 4 mounting bolts for mounting 3 AC/DC Power Supply units, M6X140
mm, DIN912 Unbrako
Highlights
SAILOR 6080 PSU
SAILOR 6081 PSU/CH
SAILOR 6090 Power Converter
SAILOR N163S PSU
Features
SAILOR 6080 PSU
• IEC 60945 Maritime approval
SAILOR 6081 PSU/CH
• AC input (100-240 VAC operating) with fuse SAILOR
(6.3 A) 6090 Power Converter
• DC output voltage: 28.7 V - 31.2 V (2 DC output connectors)
• Output powers: SAILOR N163S PSU
• 100-240 VAC: 300 W continuous, 370 W peak (2 min.) or
• 90-100 VAC: 270 W continuous, 333 W peak (2 min.)
• Automatic selection of AC input voltage range.
• AC alarm and On/off switch
• Daisy-chaining of up to three units to give up to 900 W.
• Short circuit protection
• Over-temperature protection (shutdown with automatic restart)
• Battery switch-over in case of AC supply failure, secured by 2 fuses (30 A)
• No forced cooling required
• IP 3X for internal high voltage areas (>42 V), IP 2X in other areas
• IP X2 when vertically mounted (wall) and connector panel is facing down
Technical Specifications
SAILOR 6080 PSU
SAILOR 6081 PSU/CH
SAILOR 6090 Power Converter
SAILOR N163S PSU
MF/HF system
Optional accessories:
• Wall-mount tray, heavy duty, with cable-relief bracket
Order number: 406080A-opt.001
• 4 mounting bolts for mounting 2 AC/DC Power Supply units, M6X100 mm
Order number: 406080A-opt.002
• 4 mounting bolts for mounting 3 AC/DC Power Supply units, M6X140 mm
Order number: 406080A-opt.003
Stand-Alone Installation
Wall-mount tray
Important
Wiring Connection
Protective lid
Connection – AC Input
AC Input
Connection – DC Outputs
Note
Connection – Battery
3. Remove the u-shaped cut-out for this input from the protective lid.
Cobham SATCOM
Installation
SAILOR 6080 AC/DC POWR SUPPLY UNIT
4. Remove the u-shaped cut-out for this input from the protective lid.
Important !
If you need more than 3x300 W or 30 A you can connect more than 3 AC/DC Power Supply
units as shown in the drawing. This is to make sure that a single connector is never overloaded
with more than 30 A.
• Equipment Presentation
– Products & Accessories
– Highlights & Features
– Technical Specifications
– Block Diagram
– Manual for the system
• Application
– FBB
– MF/HF
• Installation
– What’s in the box
– Stand-Alone
– Wall-Mount Tray
– Installing 2 or 3 6080 PSUs
– Connectors
– DC Output or Optional Input for Daisy-Chaining
– Special Installation if > 3x300W or 30A is needed
• Service and Repair
– Maintenance Free
– Voltage Modification Kit
– Exchanging Fuses
Maintenance Free
Exchanging Fuses
Questions ?
Products
Part No. Product Description
406081A-00500 SAILOR 6081 Power Supply incl. Charger and Tray for wall
mounting.
Accessories
Part No. Product Description
406081-004 Installation kit for 3 additional 6080 PSUs.
Accessories
Connector Panel
• SAILOR 6081 can easily be upgraded on site to more output power by adding up to 3 x 6080.
• The connection between the PSUs and the connector panel are protected against water ingress
by a protection cover.
• A cable relief bracket to secure heavy cables is integrated in the wall-mount tray.
• When mounted vertically it fulfills IP32 in areas with more than 42 V and IP22 in other areas.
• Fail Safe mode - In case of AC power failure or overload, the connected battery
delivers the required power seamlessly.
Note: Output power has a higher priority than the charging current.
• No Charge mode - If battery voltage < 8 V, the charger will not start.
• Pre-charge mode – When battery voltage < 23V, charging current of about 2 ~3A is
maintained to load deeply discharged batteries.
• Regular charging - When battery voltage > 23V, regular charging starts with
maximum charging current.
The maximum charging current and the nominal battery voltage can be adjusted.
For further details see Customizing battery settings on page 33.
Features
• Output voltage according to battery requirements (range: 24 — 31.2 V)
• 5 x DC connectors fused 2x10A, 2x20A and 1x50
• 1 x 15 V DC output (no fused)
• Up to 1480 W peak output power
• AC input (100-240 VAC) with fuse (6.3 A) with Power Factor Correction
• Automatic detection of input voltage range
• AC alarm and battery voltage alarm
• Ethernet connector for monitoring and control information
• Battery charging function
• Short circuit protection
• Over-temperature protection (shutdown with automatic restart)
• Switch over to battery power in case of AC supply failure
• No forced cooling required
• Link to control up to 8 PSU and Charger units connected to the same battery
• Upgrade on site by service personnel
• IP 32 for internal high voltage areas (>42 V), IP 22 in other areas when
• vertically mounted (wall) and connector panel is facing down
• Approval and certification: IEC 60945 Maritime approval, Wheelmark
Technical Specifications
Important
Grounding
1. Connect chassis to ship with a cable (minimum wire cross section: 4 mm2) or equivalent.
The maximum cable length is 1 m.
2. Connect the drain wire for each cable to the designated GND terminal or bolt it to the
mounting plate as shown above (2.).
3. Ground the Power Supply Unit and Charger to ship, for example at the screw holding the
mounting plate, as shown above (3.).
- When installing the power supply, make sure you connect the chassis of
the power supply to ship ground.
Connectors overview
Connector panel:
P1 ~ P4: DC Input
The C connectors are used for control data from the The P connectors for DC input from the installed
installed SAILOR 6080 units to the Connector panel. SAILOR 6080 units to the Connector panel.
Notes:
These values* depend on the size of the battery, check the documentation for the battery.
The maximum charging current and the float voltage can be configured, for further details see
Customizing battery settings on page 33.
Notes:
These limits can be changed. For further details see Customizing battery settings on page 33.
Example 1:
Two 6081 PSU/CH share one battery, each unit charges with
4 A. The charging currents shown = 8 A.
Example 2:
Two 6081 PSU/CH share one battery, one unit charges with 4
A, the other unit draws 3 A. The charging currents = 1 A.
*The maximum charging current and the float voltage can be configured, for further details see
Customizing battery settings on page 33.
Sensor probe
• On a 'double charger' solution only need 1 temperature sensor to be installed on the primary charger.
The temperature information will then be forwarded via the cross link to control both chargers.
• If two sensors are fitted, the system will act towards the sensor giving the most extreme value, giving
lowest value of the two if under 20 degrees Celsius alternatively highest value of the two if above 20
degrees Celsius.
• Installation of temperature sensor is urgent to make sure to have best possible battery maintenance.
• The X11 and X12 outputs are fused with 20A fuse.
20A ATO blade fuse p/n: S-45.665.
10A Red
Mount the jumper J500 on one PSU— and only ONE power supply in the primary segment.
• The SAILOR 6081 can provide various status and alarm information. To forward alarms correctly to the
connected devices (MF/HF, VHF, Inmarsat C, etc), it is important that each SAILOR 6081 is configured
correctly with information about the connected equipment.
You must setup each SAILOR 6081 with the following information so that each
Power Supply Unit and Charger can provide alarms etc. to the relevant
connected equipment:
Once correctly set up, the alarms and status information from the SAILOR 6081
are correctly displayed in the respective system.
Primary Duplicated
Primary Duplicated
Primary Duplicated
Primary Duplicated
Primary Duplicated
Primary Duplicated
Primary Duplicated
Maintenance Free
Alarm messages
The following alarm messages can be displayed in the Message Terminal:
The connector panel on 6081 has separately fused DC outputs. To exchange a fuse for
one of the DC outputs, do as follows:
1. Minimize the current drawn by switching off as many devices as possible.
Fuse, AC input
Not used !
The 6080 PSU has a fuse to secure the AC input. To exchange the AC fuse, do as
follows:
1. Locate the fuse, it is accessible from outside the housing. It is positioned next to
the on/off switch.
2. Turn the fuse holder and extract it.
3. Take out the old fuse and insert a new one (type: 5x20 mm, 6.3 AT).
4. Insert and fasten the fuse holder.
Notes:
a. The charging current may be lower depending on the currently available output power.
b. b. All voltages at 20° C. If a temperature sensor is mounted the voltages are compensated with -36 mV/°C.
c. If the recharge voltage is higher than the float voltage, recharging starts only when the battery voltage reaches the Recharge
voltage level.
d. Only relevant if a battery temperature sensor is installed.
*The recharge voltage is not displayed in the SAILOR 6006 Message Terminal.
Overview
• SAILOR 6081 PSU/CH can be upgraded on site with up to 3 6080 PSUs to increase the
DC power output up to 740, 1110 or 1480 W.
• The upgrade can be made on site by trained service personnel.
Questions ?
Spare Parts
Part No. Product Description
S-45.506 Fuse, 1AT 250V 5x20mm
Highlights
• The SAILOR N163S Power Supply is a sturdy and reliable work horse.
• Automatic change-over from AC mains to 24V DC, ensuring continued power.
Applications
The SAILOR N163S The SAILOR N163S Power Supply is recommended for the following
SAILOR products from Thrane & Thrane:
Technical Specifications
Specifications Values
Input Voltage 110/127 AC Fuse T2A
Input Voltage 220/237V AC Fuse T1A
Input Power Max 220W
Output Voltages 24VDC unregulated
Output Current 7A
Output Power 170W
Alarm Output Dry Contact NO/NC
Weight 5.0 Kg (11 lbs)
Operating Temperature Range -15°C to +55°C 93% Relative humidity.
Electrical Diagram
AC Input Settings
AC Input Fuse
110/127 AC T2A
220/237V AC T1A
AC Input
Maintenance Free
Warning ! Switch OFF the AC Mains and Battery breakers before replacing any fuse.
1. Turn the device that holds the fuse and extract it.
2. Remove old fuse and insert a new one
(type: 5x20 mm, 1 or 2 AT)
3. Insert and fasten the fuse holder.
Questions ?
Spare Parts
Part No. Product Description
S-45.506 Fuse, 1AT 250V 5x20mm
• Converter 24 V to 12 V DC.
• Use for providing 12 V DC for the SAILOR 6000 VHF from a 24 V DC power
source.
• Use as a CAN Bus injector providing 15V output.
• Output short-circuit protection.
Technical Specifications
Specifications Values
Input Voltage (Operational): 21V DC - 32V DC
Output Voltage 12.5V DC ±5%
Output Current (@12.5V) 8A
Efficiency (typical) > 94%
Fuse type 10A ATO mini
Current limit 8A@12.5V
Current limit 7A@15V
Dimensions
Placing Of Jumpers
Power Converter Always ON:
• For connected to Sailor 6210~6217 VHF
• Jumper W300 in place
Placing Of Jumpers
Power Converter remote on/off from VHF:
• For 6090 connected to Sailor 6222 ~ 6248 VHF
• Remove Jumper W300
Placing Of Jumpers
Power Converter with 15V Output:
• For 6090 connected as CAN injector
• Jumper W300 in place
Maintenance Free
Replacing Of Fuse
One fuse is installed in the SAILOR 6090 Power Converter. If the fuse is blown, do as follows:
1. Track down why the fuse was blown and solve the problem.
2. Take out the old fuse.
3. Insert the new fuse. The fuse rating is 10 A T.
Questions ?