• As per API 1104 clause no.11.1.6.1, when a complete weld is radio graphed
in a single exposure using a source inside the piping, at least four
pentameters placed parallel to the weld and spaced approximately equally
around the circumference shall be used.
• Radiographic sensitivity shall be as per the requirement of ASME V. Calculation of
sensitivity for DWSI shall be based on the thickness of one wall only, whereas
calculation for DWDI shall based on the combined thickness of both walls.
Personnel Qualification
10.1 Personnel performing and interpreting radiographic examinations shall be qualified in accordance with ASNT-
TC-1A or ISO standard
10.2 As a minimum all personnel conducting radiographic test shall be certified to Level-1
10.3 Radiographic test will be performed under supervision of level- Ⅱ or equivalently qualified supervisor.
10.4 Interpretation of radiographs shall be carried out by Level- Ⅱ qualified personnel.