Você está na página 1de 8

Chart Title

IQI Selection
5
4.5
4
3.5
3
2.5
2
1.5
1
0.5 Series 3

0
Series 2
Category 1
Category 2
Category 3 Series 1
Category 4
Series 1 Series 2 Series 3
• As per API 1104 clause no.11.1.6.1, when a complete weld is radio graphed
in a single exposure using a source inside the piping, at least four
pentameters placed parallel to the weld and spaced approximately equally
around the circumference shall be used.
• Radiographic sensitivity shall be as per the requirement of ASME V. Calculation of
sensitivity for DWSI shall be based on the thickness of one wall only, whereas
calculation for DWDI shall based on the combined thickness of both walls.
Personnel Qualification

10.1 Personnel performing and interpreting radiographic examinations shall be qualified in accordance with ASNT-
TC-1A or ISO standard

10.2 As a minimum all personnel conducting radiographic test shall be certified to Level-1

10.3 Radiographic test will be performed under supervision of level- Ⅱ or equivalently qualified supervisor.
10.4 Interpretation of radiographs shall be carried out by Level- Ⅱ qualified personnel.

10.5 All qualification certificates shall be current.


Acceptance Criteria for Welds
Reports

13.1 Written reports of all radiographic examinations shall


include ,but not limited to the following items:
a. Identification of parts, materials or area, wall thickness,
diameter
b. The Radiographic Job number
c. The findings and disposition
d. Name of the radiographer
e. Name of the interpreter
f. Types of Radiation Source
g. Pentameter/IQI Type
h. Film Density
i. Film type
j. Technique used
Preliminary interpretation
Radiation Safety
Safety & Security
a. All technicians shall wear a TLD and a pocket dosimeter during radiation work
b. They should have a calibrated radiation survey meter.
c. The area where the radiation work is being performed shall be cordoned off to prevent
unauthorized entry.
d. After complete of work isotope should be kept at storage pit under lock & key
e. Collimator will be used specially where Radiography will be undertaken by gamma Ray.
f. All regulations and specifications approved by Bangladesh Atomic Energy commission will be
followed.