Chapter 09 page 1

FTV2.3

POWER SUPPLY

REPAIR METHOD
Check VS and VA Output Load Chapter 09 page 2

SERVICE TIP:
If the Vs input of the PDP is short circuited a simple test can be done:
Disconnect the set from the mains.
Disconnect ALL cables between PSU and PDP.
Connect a regulated DC power supply (current limited to 1 A) directly to the Vs input of the YSUS board of the
PDP (pin 9 of connector CN 33) and the chassis of the FTV.
Ramp-up the voltage slowly to maximal 5 V. If the current increases to 1 A, the PDP is defect.
The same can be done for the Vs input on the XSUS board: pin 10 of connector CN 23.
 
The Va inputs on the various boards can also be checked with the same procedure:
The tests must be done on the connectors
CN23: pin 1 (XSUS-board)
CN42: pin 1 (ABUSR-board)
CN52: pin 1 (ABUSL-board).

The next pages explains how to repair the power supply outside the
set, with fictive loads
Repair The Power Supply Out the Set Chapter 09 page 3

 Short circuit On/Off switch, pin 1 and 2 connector 319. 

 Connect VCEGO (p13) and VSAGO (p15) of CN307 to a +2,5V from the +3,3v STBY SW.

 For a regulated output voltage, connect test point VRS (pin 7) and VRA (pin 9) of CN307 to + 1V.
Connect to the two solder island near connector 307 (flex foil connector). 

 Load +3,3V stby with 15 Ohm resistor (I must be 0,2A). 

 Load Vs with Lamp on CN323 pin 10. (lamp220V/75W I =176mA (82,3V))

 Vs Min load between 0,1 to 0,5A, Max load = 0,5A

 Load VA with lamp on CN 323 pin 1. (lamp 220V/100W I = 200mA (53,6V))

 VA Min load between 0,1A to 0,5A Max load = 2A

 Load Vcc (5V) with resistor 8,2 Ohm, the Max load for VCC = 7A.

 Load 3V3 with resistor 3,3 Ohms or 1,5 Ohm

 Connect power supply to mains, by connector 308. 


Output Connectors Chapter 09 page 4

CN319 P3 CN333 and CN323 P7 CN307 P3

Pin 9

Power OK

VSAGO 2,5V VCEGO 2,5V VRA & VRS 1V

P7
P3
Flow Chart Overview Check Points Chapter 09 page 5

Check+V
Check +Vstandby
standbypower
powersupply,
supply,++3,3V
3,3Vand
and+5V
+5Vstby
stbyon
onCN319.
CN319.

CheckPreconditioner
Check Preconditioner+395V
+395Von
onfuse1004.
fuse1004.

Check+Vs
Check +Vsswitched
switchedoutput
outputvoltage
voltageon
onpin
pin8,9,10
8,9,10CN323
CN323or
orpin
pin7,8,9
7,8,9CN333
CN333
around80……85V
around 80……85V

Check++Va
Check Vaoutput
outputvoltage
voltageon
onpin
pin11CN323
CN323==around
around50….55V
50….55V

Check++Vcc
Check Vccoutput
outputvoltage
voltageon
onpin
pin11CN333
CN333==5,2V
5,2V

Check++3V3
Check 3V3output
outputvoltage
voltageon
onpin
pin8,9,10,11,12
8,9,10,11,12of
ofCN305
CN305==3,3V
3,3V

CheckPower
Check PowerOK
OKline
lineon
onpin
pin99CN319,
CN319,must
mustbe
behigh
high(4,5V).
(4,5V).
Switched Standby Voltages Chapter 09 page 6

in Ic7500
Pin 5 Dra

Minimum load for the +3,3V switched Stby supply

is about 0,2A or 16 ohm

+5V Stby out +3,3V Stby out P2


Standby Supply Is Not Correct ? Chapter 09 page 7

Conditions for normal operating mode of the Stby supply;

Load is about 200mA on the 3,3V output Check V on

drain IC7500?
<100V

>100V
Fus.1400,

D6512, D6513, R3506


Pin 1 IC7500 = 5,8V ?

Check also
Check secondary part
the +25V Hot from Stby PS
Short circuit and
Reference is primary ground
Control loop
P2
Check Preconditioner Chapter 09 page 8

Drain T7610

Pin 11 Gate

Pin 13 oscil.
Preconditioner output
Fuse 9004 = 395V

P5
Check Preconditioner Chapter 09 page 9

In normal working conditions Output of D6600 =255V


output of preconditioner = 395V on
fuse 1004 V start-up pin 16 IC7650 = 395V

Check on IC7650
•Pin 12 Vcc = 14,5V

Tip, it is also possible to check •Pin 1 Vref = 5V


the preconditioner without load •Pin 13 Oscilator
by removing fuse 1004

Pin 11 Gate

Check +25V Hot


Voltage feedback pin 3 VFB =5V
preconditioner output = 24,5V
Current sense pin 6 CS P5
Start up Conditions LLC Supply Chapter 09 page 10

Standby supply is switched on and is in continous mode, 3,3V and 5V standby are OK Diagram P2

VCEGO and VSAGO are connected to 2,5V Check Load on standby supply
Diagram P3

T7352 conducts, T7348 is blocked Check latch, Thy6348 must be blocked,

P3 If not check protection part P3


T7391 is blocked, T73993 is blocked

Diagram P2
Supply_on line = H and T7460, T7465 and T7470 conducts
P2

Relay 1450 & 1460 is closed

Diagram P5
P5
395V Preconditioner is OK

Diagram P6
25V_Hot Standby Supply is OK
P6
SW25V_Hot from preconditioner is OK
Check +16V provided by Ic7093

Oscillator and OA/OB Ic7001


Ic7093 provide current to pin 15 control IC7001 LLC supply
Check Vs Supply (LLC) Chapter 09 page 11

LLC control IC Bias supply IC7093 Primary ground

+Vs switched
4
on pin 10 CN323

Vs=70+10Vrs
Pin 3 and 6 T5002 = around 80 …85V
or C2011/C2017
P6
Check LLC Supply Control Part IC7001 Chapter 09 page 12

Start up conditions +25v HOT from stby


supply and SW25V Hot from
preconditionner are OK?

Check DC voltages IC7001 Pin


•15 Vcc = 16,5V

•5 Vref = 5,1V

•10 Fault input = 0V

P6

Check by oscilloscope IC7001 Pin


If LLC control part does´n start up
1 Oscil, drive output 14 OA, 12 OB check with external DC power
supply, see next page
Check LLC Control Part, With External DC Power
Chapter 09 page 13
Supply

Connect a external DC power supply

The + to the output of IC7093 (metal part), - to primary ground on cooling plate LLC

Oscilloscope is connected to oscillator pin 1

Adjust the current output of the external DC power supply to 100mA max

Adjust the output voltage to 16V

Control Ic is starting up at 16V, current = 70mA

Check oscillator, One shot timer

OA and OB

Grid Ts7005, Ts7006


P6
See voltages and oscillogrammes next page
LLC Supply Control Part Chapter 09 page 14

One shot

oscil 4,3V
17V

2,7V OA

IC7001
Ref 5,1V MC34067P OB

1,8V 4,9V

4,9V 0,6V

P6 4,9V
VS Switch & Sequence Discharge Circuit Chapter 09 page 15

Start Up Sequence
Switch Off Sequence

LLC has started LLC is switched off

Or +5V standby is switched off


Pulses are aligned and rectified by D6054 & D6055 Or Power OK line drops

VS drops & Power OK Line will drop


Power OK line is H T7058 conducts

VSA_Control Line will be High


VSA_Control is Low

T7058 will block


T7059 & T7052 are blocked
T7059 conducts

T7050 blocks
T7050 conducts

P7
T7052 conducts andVS is directly discharged,
Vs is switched while VA is discharged if VS is lower than VA
Sart Up Conditions VA Supply Chapter 09 page 16

LLC supply has started up and Vs unsw. 77V…95V from LLC is OK

Diagram P3
VSAGO is connconnected to +2,5V

P3 T7376 and T7375 conducts Vs_unsw = OK, T7375


coducts
Digram P7
VSA_control line is Low, T7134 is blocked

Start up current is provided by Check also T7058


T7110, T711 and from Drain
Power OK line will be
Ic7112 to pin 1 VCC
H but with some delay

P7 Start up VA
Check VA Supply Chapter 09 page 17

VA Control Ic7112

Drain T7117 VA DC output pin 1 CN323

1 +VA on pin 1 CN323

Va=30+20Vra

= around 50…..55V.

CN323 P7
VCC Supply Start up Conditions Chapter 09 page 18

LLC is OK

Diagram P3
CN307 pin 13 VCEGO=2,5V P3

Ts7352 conducts, Ts7351 is blocked

VCC_Go and +18V LLC are on H


Diagram P7
level
P7

T7200 conducts and provide start up curent

Start up current is provided by Drain Ic7212


VCC Output Voltage Chapter 09 page 19

Check +VCC = 5,2V


3
or pin 3 CN323

Grid T7217 Drain 7217

CN323

P7

Control IC7712
3V3 Start up Conditions Chapter 09 page 20

Diagram P6
+18V from LLC supply is OK

Diagram P7 IC7260 VCC pin 7 & 8 = 17V

3V3 OVP is Low, Thy6260 is blocked

Check 3,3V OVP

T7389 & IC7330C


Check Oscillator pin 1

P7
3,3V Supply Chapter 09 page 21

Oscillator Pin1 Pin 17 SS Output Pin2/3 Pin 9 Boot 3V3 output

P7
3V3 Power Supply Repair With External DC Power
Chapter 09 page 22
Supply

Check if there is no short circuit on the output.

Connect an external DC power supply on C2261 and


adjust the output to 19V, limit the current to 700mA max.

Check the output voltage 3,3V ?

Oscillator pin 1

Vcc = 19V

Pin 16 = 5,1V.

Pin 17 SS = 18V

Pin 11 = 0,7V
P7
Pin 12 = 3,2V (if power supply is OK)
Alignment Vs and Va After Power Supply Repair Chapter 09 page 23

VA adjust R3127

VS and VA test connector


VS adjust
After repair the +Vs and +VA must be
adjusted
Additional Info For Power Supply Alignment Chapter 09 page 24

Please keep in mind that in case of the following combinations between PSU's and PDP's no or almost no
alignments are needed of the Vs and Va:
 PDP with only the Vs feedback loop (-52 in type number of PDP) in combination with the .3 PSU: Keep the SW
feedback loop OFF and align both the Vs and Va as described in the Service manual.

 PDP with only the Vs feedback loop (-52 in type number of PDP) in combination with the .3 PSU with precision
resistors: The SW feedback loop can be switched on and then the Va has to checked and aligned with an accuracy of
+/- 1,5V and the potentio meter of the Vs should be positioned in the middle. No further alignments needed.

 PDP with only the Vs feedback loop (-52 in type number of PDP) in combination with the .4 PSU: Switch on the SW
feedback loop and no further alignments are needed.

 PDP with the Vs & Va feedback loop (a "B" in the type number of PDP) in combination with the .3 PSU: Keep the SW
feedback loop OFF and align both the Vs and Va as described in the Service manual.

 PDP with the Vs & Va feedback loop (a "B" in the type number of PDP) in combination with the .3 PSU with precision
resistors: Switch on the SW feedback loop and no further alignments are needed.

 PDP with the Vs & Va feedback loop (a "B" in the type number of PDP) in combination with the .4 PSU: Switch on the
SW feedback loop and no further alignments are needed.

The SW feedback loop can be found in the SAM menu.


Chapter 09 page 25

End of the repair method


presentation

For your reactions, questions or comments contact

valere.deseranno@philips.com

Você também pode gostar