Você está na página 1de 1

NOTAS

1) VERIFICAR MEDIDAS NO LOCAL.


2) MEDIDAS EM MILÍMETROS E ELEVAÇÕES EM METROS.
1' 2' 3' 4' 5' 6'
3) MATERIAIS:
- PERFIS W: ....................... ASTM A572 GRAU 50 (fy=345MPa)
19950 - PERFIS U e CHAPAS: ..... ASTM-A36 (fy=250MPa)
D' - ELETRODO DE SOLDA E-70XX DE ACORDO COM A NORMA AWS D1.1:2015
4450 2475 2675 4025 6325 - PARAFUSOS, PORCAS, ARRUELAS: ASTM-A 325 OU EQUIVALENTE.
4) O PERFIL, PARAFUSOS, ARRUELAS E CHUMBADORES DEVERÃO SER ZINCADOS POR
1700
PAINEL C2-3 1710 1710 1710 1710 1710 1710 1710 1710 1710 1710 1710 PAINEL C1-3
IMERSÃO A QUENTE, CONFORME NBR6323, NÃO EXECUTAR SOLDAS
PAINEL 1-3 PAINEL 1-3 PAINEL 1-3 PAINEL 1-3 PAINEL 1-3 PAINEL 1-3 PAINEL 1-3 PAINEL 1-3 PAINEL 1-3 PAINEL 1-3 PAINEL 1-3
422 855 422
695 695 APÓS A ZINCAGEM.
3 DETALHE 5) A COR DAS ESTRUTURAS METÁLICAS DEVERÁ OBEDECER ÀS ESPECIFICAÇÕES
795,51 10 10
004
Cobertura INDICADAS NO PROJETO DE ARQUITETURA - COR GRAFITE MUNSELL N3,5

10 6) NORMAS UTILIZADAS PARA O DIMENSIONAMENTO DAS ESTRUTURAS:


795,21 795,21

325
300
A'

415
415
- NBR-8800 - PROJETO E EXECUÇÃO DE ESTRUTURAS DE AÇO DE EDIFICIOS.
7) CARREGAMENTO PREVISTO PARA O DIMENSIONAMENTO DA ESTRUTURA:
DETALHE 2 DETALHE 2 DETALHE 2 DETALHE 2 DETALHE 2
004 004 004 004 004 - PESO PRÓPRIO DOS PERFIS E CONEXÕES ............................... 7 850 Kgf/m3
PAINEL 1-3

PAINEL 1-3
- PESO DO REVESTIMENTO DE FACHADA "BRISE SOLEIL" ........ 14 Kgf/m²
3 DETALHE DETALHE 3
1710

1710
2 DETALHE - VENTO NA FACHADA ..................................................................... 125Kgf/m²
004 004
004
- A ALTERAÇÃO DO CARREGAMENTO DEVE SER SUBMETIDA À APROVAÇÃO DA
2 2
3350

DETALHE DETALHE PROJETISTA


004 004
8) VERIFICAR COMPATIBILIDADE DO EQUIPAMENTO A FORNECER COM A ESTRUTURA.

9) COMPETE AO FORNECEDOR DAS ESTRUTURAS METÁLICAS, POR OCASIÃO DA SUA


PAINEL 1-3

PAINEL 1-3
22 22 22 INSTALAÇÃO, GARANTIR A EQUIPOTENCIALIDADE POR MEIO DA CONEXÃO GALVÂNICA
1710

1710
COM AS ARMADURAS DAS ESTRUTURAS DE CONCRETO NOS PONTOS PREVISTOS
NOS DOCUMENTOS TÉCNICOS DE CLASSE 6P9 (BARRAS CHATAS DE AÇO - NICHOS DE

3560
B' ATERRAMENTO

3235
3240

3240
10) PINTURA DAS ESTRUTURAS:
08 07
* JATEAMENTO ABRASIVO AO METAL QUASE BRANCO, RUGOSIDADE CONFORME
PADRÃO SA 2,5 / SSPC-SP10.
PAINEL 1-3

PAINEL 1-3
* APLICAÇÃO DE TINTA À BASE DE EPÓXI MASTIC COM A FUNÇÃO DE FUNDO /
1710

1710
2900

ACABAMENTO APLICADA EM FÁBRICA, NA ESPESSURA DA PELÍCULA SECA DE 150


DETALHE 2
004
2 DETALHE MICRAS.
004
* APLICAR RETOQUES NO LOCAL DA OBRA APÓS A MONTAGEM DAS ESTRUTURAS,
NOS LOCAIS DANIFICADOS PELO TRANSPORTE E IÇAMENTO DAS ESTRUTURAS.
2 DETALHE * A COR DAS ESTRUTURAS DEVERÁ OBEDECER ÀS ESPECIFICAÇÕES INDICADAS NO
PAINEL 1-3

PAINEL 1-3
01 02 03 04 05 06
004
CADERNO DE ARQUITETURA - GRAFITE MUNSELL N3,5
12550

10
1710

1710
C' 791,92 791,97
791,95

10
Cobertura

20
LEGENDA
2 2
PAINEL 1-3

PAINEL 1-3
DETALHE DETALHE
DETALHE 2 004 004
1710

1710
004 PILAR SEGUE

2 DETALHE
PILAR NASCE
004

PILAR MORRE
6300

PAINEL 1-3

PAINEL 1-3
FURO
1710

1710
REBAIXO
Esta folha é de propriedade da Companhia do Metrô e seu conteúdo não pode ser copiado ou revelado a terceiros. A aprovação deste documento não exíme o emitente de sua responsabilidade sobre o mesmo

4220
2 2
PAINEL 1-3

PAINEL 1-3
DETALHE DETALHE
004 2 004

4530

4540
DETALHE
1710

1710
695 1710 1710 1710 004 DETALHE 2 21 21 21
004 1100 695

DETALHE 2 700 2 DETALHE DOCUMENTOS COMPLEMENTARES


004 004
415

415
DE-15.25.02.02/6K1-002
D' DE-15.25.02.02/6K1-003
DE-15.25.02.02/6K1-004
DE-15.25.02.02/6K1-005
DE-15.25.02.02/6K1-006
PAINEL C1-3 PAINEL 1-3 PAINEL 1-3 PAINEL 1-3 PAINEL 2-3 PAINEL 3-3 PAINEL C2-3
17/04/2018

REVESTIMENTO DA FACHADA
VER PROJETO DE ARQUITETURA
17/04/2018

PLANTA - BARRILETE CENTRAL DE VENTILAÇÃO- NÍVEL 791,95


ESC. 1:50 2 DETALHE
787,73
004
S. Técnicas 2
10
787,43 787,43

300

10
1' 2' 3' 4' 5' 6'

19950
2 DETALHE DETALHE 2
004 004
4450 2475 2675 4025 6325 REPRESENTAÇÃO DE NÍVEIS:

PAINEL C2-3 1710 1710 1710 1710 1710 1710 1710 1710 1710 1710 1710 PAINEL C1-3
PAINEL 1-3 PAINEL 1-3 PAINEL 1-3 PAINEL 1-3 PAINEL 1-3 PAINEL 1-3 PAINEL 1-3 PAINEL 1-3 PAINEL 1-3 PAINEL 1-3 PAINEL 1-3
750,28 (N.A.)
NÍVEL DO PISO ACABADO
695 695 750,28 (N.A.)

2220
750,05 (N.O.) 750.05 (N.O.)
NÍVEL DO PISO EM OSSO

2520
2516

2640
20 20 20 750,28 NÍVEL DE TOPOGRAFIA (GERAL) 750,28

A'

415
415

DETALHE 3 DETALHE 3 DETALHE 3 DETALHE 3 DETALHE 3 0 2 4 10m 0 0,5 1 2,5m

004 004 004 004 004 1:200 1:50


1
PAINEL 1-3

PAINEL 1-3
DETALHE
785,21 ESCALA GRÁFICA ESCALA GRÁFICA
004
1710

1710
3 Porão Cabos 1 5
DETALHE 0 2 5m 0 10 25cm

004 1:100 1:5


784,91 10 784,91

300
3350

DETALHE 3 3 DETALHE ESCALA GRÁFICA ESCALA GRÁFICA


004 004

125
A B C D E F

A' B' C' 3'


PAINEL 1-3

PAINEL 1-3
A'' B'' C'' D''

10 10
1 DETALHE DETALHE 1
1710

1710
004 004
422 855 422

B' 1700

CORTE CHAVE
PAINEL 1-3

PAINEL 1-3

RU AL
1710

1710

DE
A
AN EID

N
DR A
M
2900

ICO

É
TECN
ED.
3
DETALHE
004
3 DETALHE CORTE TÍPICO DOS PAINÉIS ELEVAÇÃO TÍPICA DOS PAINÉIS ACE
SSO
A
004
ESC. 1:25 ESC. 1:25

FI
HOH
EB C
AGU
PAINEL 1-3

PAINEL 1-3

AV. R
12550

1710

1710

C'
AV. RAGUEB CHOHFI

GUIA PROPOSTA

ESTAÇÃO
PAINEL 1-3

PAINEL 1-3

AV. RAGUEB CHOHFI


1710

1710

DETALHE 3 Baia Acessibilidade

004
AV
.R
CH AGU
3 DETALHE ACESSO B OH EB
FI

004

PLANTA CHAVE
6300

PAINEL 1-3

PAINEL 1-3

Hospital Cidade Tiradentes


1710

1710

Cidade Tiradentes
Márcio Beck
Vila Prudente

Camilo Haddad

Jacu-Pêssego
Oratório

São Lucas

Érico Semer
Jardim Planalto
Vila Tolstói

Fazenda da Juta

Jequiriçá
Vila União
PAINEL 1-3

PAINEL 1-3

3 3

Iguatemi
DETALHE DETALHE

São Mateus
3
1710

1710

Sapopemba
004 DETALHE 004
695 1710 1710 1710 004 DETALHE 3
004 850 695

700
DETALHE 3 3 DETALHE N
004 004
415

415

D'
ESQUEMA DO TRECHO

PAINEL C1-3 PAINEL 1-3 PAINEL 1-3 PAINEL 1-3 PAINEL 2-3 PAINEL 3-3 PAINEL C2-3 REVESTIMENTO DA FACHADA
VER PROJETO DE ARQUITETURA

Descrição da Revisão
PLANTA - COBERTURA - NÍVEL 795,06
ESC. 1:50

OBSERVAÇÕES CÓDIGO DOCUMENTOS DE REFERÊNCIA EMITENTE ANÁLISE TÉCNICA LIBERAÇÃO


OBJETO AUTOR / PROJETISTA / FORNECEDOR CONTRATADA METRÔ / CONTRATADA METRÔ
CONSÓRCIO
ALENA, CONSULGAL S.A., GEM Linha 15 - PRATA Trecho / Sistema São Mateus - H.Cid.Tiradentes
CONSULGAL BRASIL, FERCONSULT
Subtrc./ Subsist./ conj. 02 - Estação Iguatemi UC/ Subconj. 02 - Salas Técnicas
CONTRATO Objeto
CONTRATO 4059221301 Projeto Executivo
COLOR 1(preto) - PENA 0,10
OS E-2547 OS E.T.O
COLOR 2(preto) - PENA 0,20
RESPONSÁVEL TÉCNICO RESPONSÁVEL TÉCNICO RESPONSÁVEL TÉCNICO NOME PLANTA - BARRILETE CENTRAL DE VENTILAÇÃO E COBERTURA
COLOR 3(preto) - PENA 0,30

COLOR 4(preto) - PENA 0,40


PLANTA , CORTES E DETALHES
COLOR 5(preto) - PENA 0,50 Escala Código Folha Rev.
COLOR 6(preto) - PENA 0,60
MC-15.25.02.02/6K1-001 MEMÓRIA DE CÁLCULO - APOIO PARA OS BRISES
CELIO EMERIQUE
REGISTRO 5062095045-SP
GONÇALO VENTURA
REGISTRO 5069360733-SP
FABIO ABREU
REGISTRO 600416634-SP INDICADA DE-15.25.02.02/6K1-003 1 1 2
COLOR 7(preto) - PENA 0,70
ART / RRT 92221220140491819 ART / RRT 28027230180395889 ART / RRT 92221220130161949 REGISTRO
COLOR 8(preto) - PENA 0,80 DE-15.25.02.02/6J2-001 a 012 PROJETO EXECUTIVO DE ESTRUTURAS - ETO
MODALIDADE ENGENHARIA CIVIL MODALIDADE ENGENHARIA CIVIL MODALIDADE ENGENHARIA CIVIL
COLOR 9(preto) - PENA 0,90
DE-15.25.02.00/6B3-035 a 048 PROJETO EXECUTIVO DE ARQUITETURA - ETO DATA 26/06/2018 DATA 26/06/2018 DATA DATA *DE-15.25.02.02/6K1-003*

Você também pode gostar