Você está na página 1de 1

05 06 05 06 05 06 05 06

08
07
DIMENSOES
07 Y X REBITES
LARGURA DO DUTO
DUTO C/ ALTURA ATE
150 ATE 600 75 75 500mm USAR REBITE
850
10 10 PPO 440S
Ø8"
03
610 ATE 900 125 50
QAC DUTO C/ ALTURA ACIMA
910 ATE 1220 80 79 500mm USAR REBITE
DE ALUMINIO Ø5/16"x3/8"
250x250 1230 EM DIANTE 255 100
850
12.28

1260x600 1260x600
13600 13600
JOELHO RETO COM VEIAS
400x250
1760

01
1000x600
400x250 280
5400
1760
Ø6"
200x250
630
11
1100x600
11870

Ø8"
Ø8"
02 350

UE.03
09
350 Ø6"

200x200
02

280
600x600
03 03 03 03 5400
280

1250 1250 935 01

1100x600
935

11870
Ø8"

Ø8"

Ø8"

Ø8"
500x300 600x300 600x400
2500 3235 4170
250x300 1600x1000
1250 21800

PLANTA RETAGUARDA

TOTEM

Ø8"
450
04 02

4360

1100x400
SIMBOLOGIAS

7500
QAC - QUADRO DE ALIMENTAÇÃO E COMANDO VAZÃO EM m3/h DIMENSÕES DO DUTO EM mm LINHA DE LÍQUIDO

GAE - GABINETE DE VENTILAÇÃO - AR EXTERNO SENTIDO DO FLUXO 300x250


860 DIÂMETRO DO TUBO EM pol.
580

1260x600
03 03 03 03 03 03 TAE - PONTO DE ENTRADA DE AR EXTERNO VAZÃO DO TRECHO EM m3/h

13600
L.L. 3/8" - TUBULAÇÃO DE REFRIGERANTE
1250 1250 1250 1250 1250 1300x1000
DIÂMETRO L.G.5/8" EM COBRE (ISOLADA)
17440
1250 COLARINHO C/
UE-x - UNIDADE EVAPORADORA TIPO SPLITÃO EM pol. DIÂMETRO DO TUBO EM pol.
Ø6 REGISTRO DUTOS DE INSUFLAMENTO
UC-x AR CLIMATIZADO
Ø8"

Ø8"

Ø8"

Ø8"

Ø8"

Ø8"
- UNIDADE CONDENSADORA TIPO SPLITÃO LINHA DE GÁS
Ø8" - PONTO DE FORÇA DUTO FLEXÍVEL
380 DUTOS DE RETORNO
(PROJETO ELÉTRICO) ISOLADO
500x300 500x300 E RENOVAÇÃO DE AR EXTERNO
600x300 600x400 DR. ø3/4"
2500 2500
3750 5000 - PONTO DE DRENO
250x300 250x300 02 (PROJETO HIDROSSANITÁRIO) TUBULAÇÃO DRENO
1250 1250

Ø6"

04 MATERIAIS
280
ITEM DESCRIÇÃO FABRIC. QUANT.
4360
01 01 DIFUSOR COM REGISTRO E PLENUM AK6 PARA INSUFLAMENTO, ADLK-AG TAM. 3, 356x356 TROX 03

02 DIFUSOR COM REGISTRO E PLENUM AK6 PARA INSUFLAMENTO, ADLK-AG TAM. 4, 412x412 TROX 04

03 DIFUSOR COM REGISTRO E PLENUM AK6 PARA INSUFLAMENTO, ADLK-AG TAM. 5, 468x468 TROX 21

04 GRELHA DE RETORNO COM REGISTRO, AR-AG 1225x525 TROX 05


03 03 03 03 03 03 05 TOMADA DE AR EXTERIOR COM FILTRO F754, VDF 1197x697 mm TROX 08

1260x600
13600
1250 1250 1250 1250 1250 1250
1000x1000 06 VENEZIANA PARA DESCARGA DE AR, AWK 1197x97 TROX 04
13080
07 UNIDADE CONDENSADORA TIPO SPLITÃO 20 TR - GABINETE VERTICAL - MODELO REF.: UCAT-20 TOSI 02
Ø8"

Ø8"

Ø8"

Ø8"

Ø8"

Ø8"
OBSERVAÇÕES:
08 UNIDADE CONDENSADORA AUTÔNOMA TIPO SPLIT 12.000 BTU/h HITACHI 01

500x300 09 UNIDADE EVAPORADORA AUTÔNOMA TIPO SPLIT 12.000 BTU/h HITACHI 01


600x300 600x400
2500 900x400
3750 5000 1100x400
250x300 6250 10 UNIDADE EVAPORADORA TIPO SPLITÃO 20 TR - GABINETE HORIZONTAL - MODELO REF. SST-20 TOSI 02
7500
1250
04
11 GABINETE DE VENTILAÇÃO DE AR EXTERNO VAZÃO 5400 m³/h - MODELO REF.:BBT 315 BERNILER 01

700x400
5000

1000x650 DOCA E
FF17
153.12m²
TERRAÇO COBERTO
228.17m²

FF18
154.86m²

DOCA D
113

8720
FF08 16.00m²
31.42m² FF09
PRAÇA DE ALIMENTAÇÃO
3033.75m² 63.96m²

FF07 FF10
66.18m² 48.41 m²

FF11
FF06 48.38 m²
62.02m²

FF04/FF05 FF12
48.37 m²
56.18m² ENTRADA 04
FF04 FF13
40.06 m² 48.37 m²

CINEMA FF14
FF03 48.37m² 054
48.12 m²
64.24m²
FF02 FF15 ADMINISTRAÇÃO
ENTRADA 03 48.12 m² 48.37m²
055
R1 42.77m²
908.50m² FRALDÁRIO
DOCA C
FF01 FF16 056
87.42m² 74.45m² 42.70m²

053 057
R2 SANIT.FEMININO SANIT.FEMININO E F/G H 17.16 41.38m²
240.77m² 024 974.25m² 1734.55 m² 675.49m² 052 058
026
45.46 SANIT.MASCULINO 17.15 41.38m²
45.32 028 029 030
001 53.41 53.48 72.29 051 059
36.72 010/011 017 018 019 020 021 022 023 025 027 17.15
37.56m²
SANIT.MASCULINO 42.37 39.30 36.54 31.86 62.97 54.38 52.57 46.60 46.94 031 032 033
002 493.85 m² 060
36.70 34.16 40.48 45.83 050
B C 17.15 37.54m²
003 890,07m² 375,09m²
061
35.71 004 005 006 007 008 36.57m²
012 013 014 015 016 034 035 036 048 049
30.55 40.22 44.26 38.25 41.18 49.49 042 043 044 045 046 047
37.28 35.32 49.56 44.52 29.70 28.79 46.60 039 040 041
44.21 46.09 44.85 48.46 45.55 42.41 38.33
26.72
39.45 41.56 43.36

111 112
15.00m² 095 094 093 092 091 090 089 088 087 086 085 084 083 082 081 080 079 078 077 076 075 25.00m²
A 57.11 61.31 52.48 52.26 49.28 50.03 121.41 50.83 44.86 45.89 45.94 46.65 49.27 121.29 49.09 50.22 48.77 58.31 43.25 39.71 37.51 J
00 0

1879.60m²
1876.64m² 103 102 101 100 099 098 097 096 074 073 072 071 070
31.04 37.15 40.63 44.70 49.04 53.14 57.96 106.14 069
50.08 46.16 42.63 39.09 35.91 33.90
50 x40

110 109 063 062


107 105 104
48.81 44.80 108 106 068 067 066 065 064 45.12 49.25
41.60 39.03 172.38 57.97 63.12
61.61 58.25 172.33 39.46 41.45

DOCA F

P O M DOCA A
DOCA B K
1172.78m² 551.46m² 938.43m² ENTRADA 02
ENTRADA 01 1019.45m²
0
70

R
1018.67m²

04
Ø8"

LOCALIZAÇÃO DA ÁREA TÉCNICA - MEZANINO


03 03 03
0
30 LOCALIZAÇÃO DA LOJA - NÍVEL TÉRREO
1250 1250 1250 0x 50 1250
60 37
03 19/04/2022 REVISÃO RENOVAÇÃO DE AR

03
Ø8"

Ø8"

Ø8"

02 15/04/2022 REVISÃO GERAL

01 17/03/2022 REVISÃO GERAL


500x300 1000x350
600x300
250x300
2500
3750 4360 NOTAS: 00 25/02/2022 EMISSÃO INICIAL

1250
Revisão Data Modificações

1 -DIMENSÕES EM CENTÍMETROS, EXCETO ESPECIFICAÇÃO EM CONTRÁRIO. PLANTAS DE REFERÊNCIA


2 -NUMEROS ENTRE PARENTESES INDICAM VAZÃO DE AR E AGUA EM m3/h. TITULO PRANCHA NOME DE ARQUIVO

3 -CONFERIR E RATIFICAR TODAS AS MEDIDAS NA OBRA.


04 4 -TODAS AS BOCAS DE AR DEVERÃO CONTER REGISTROS PARA REGULAGEM DE VAZÃO CONFORME INDICADO NO DESENHO DE PROJETO.
5 -AS MARCAS CITADAS EM DESENHO SÃO PARA SIMPLES REFERÊNCIA.
6 -OS DUTOS DE AR CONDICIONADO DEVERÃO SER ISOLADOS TERMICAMENTE COM MANTA DE LÃ DE VIDRO DE 38mm DE ESPESSURA
DENSIDADE 20 Kg/m³ REVESTIDAS EM UMA DAS FACES COM KRFT ALUMINIZADO, REF. ISOFLEX DA SANTA MARINA OU OWENS CORNING).
7-REALIZAR O BALANCEAMENTO DAS VAZÕES DE AR E ÁGUA INDICADAS NO PROJETO.
8 -FICA A CARGO DA CIVIL TODO SERVIÇO DE ALVENARIA TAIS COMO, RECOMPOSIÇÃO DE PAREDES, BASES PARA EQUIPAMENTOS,
FURAÇÕES EM PAREDES OU LAJES, PONTOS DE ÁGUA E DRENO.
9 -OS DUTOS DEVERÃO SER FABRICADOS EM CHAPA DE AÇO GAVANIZADA NAS BITOLAS INDICADAS PELA NBR-16401 DA ABNT, SEGUINDO
OS PADRÕES CONSTRUTIVOS RECOMENDADOS PELA SMACNA.

10 -TODAS AS CURVAS DE 90° DEVERÃO CONTER VEIAS DEFLETORAS FIXAS. DESENHO EXECUTADO POR: LOJA:

11 -A AQUISIÇÃO E INSTALAÇÃO DE TODOS OS COMPONENTES DO SISTEMA DE HVAC FICA A CARGO DO LOJISTA.


12 -AS CURVAS OU JOELHOS PARA OS DUTOS DE EXAUSTÃO DE GORDURA, NÃO DEVEM POSSUIR VEIOS INTERNOS
R2A
ARQUITETURA
&ENGENHARIA
LOJA
AVENIDA
CRESCENDO POR M²

PLANTA DO PAVIMENTO TÉRREO - LOJA PROJETO: FOLHA/ REVISÃO:


PROJETO DE CLIMATIZAÇÃO
ASSUNTO:

PROJETO GERAL DE CLIMATIZAÇÃO


PISO/ TÉRREO / LOJA "B" ESCALA:
1
INDICADA
LOJA N°:
ENGENHEIRO:
AVENIDA

TIAGO EVANGELISTA
DATA:
17/02/2022
3

Você também pode gostar