Você está na página 1de 1

A F A C F

DETALLES DE PLANTA DE CIMENTACIÓN


8.80 8.80

8.65 3.90 4.75


0.30
0.15 0.15 0.15 0.10

EJERCICIO:
C2 C3 C3 C3 C3 C2 C2 C2

FASE 2
5

5
4

4
C1
C5 C5 C2 C3 C3
N 4 Ø 1/2" EST. 4 Ø 3/8" EST. 2 Ø 3/8" ESl.
Z2 4 Ø 1/2" EST.
C5 C5
Ø 1/4" @ 0.15 Ø 1/4" @ 0.15 Ø 1/4" @ 0.15
Ø 1/4" @ 0.15

0.15
Z1 4 Ø 5/8" + 4Ø 1/2"EST.

0.15

0.15

0.20
Ø 3/8" @ 0.15

0.30
C5 C5

3.69

3.69

3.69
C5
C5
C5
COLUMNA TIPO C-2 COLUMNA TIPO C-3 MOCHETA C-5
C6 C6 ESC: 1/10 ESC: 1/10
ESC: 1/10
COLUMNA TIPO C-4
6.00

Z1 C5 C5
Z1
Z2 ESC: 1/10
C1 C2 C2
C2 COLUMNA TIPO C-1

4
C1

3
C2 C3 C3 C3 C3 C2 ESC: 1/10
C3 C2

1.65
0.15

2.31
C2 C5 C2
0.15 0.15
Z1 C3 C2 C2

Z2 C2 C5
Z2 C3 0.10
C2
3

3
12.30

12.30

12.30

12.30
C2 C1 C5

5.09
C2 4 Ø 3/8" EST.
C1
2 Ø 3/8" ESl. 4 Ø 3/8" EST. 4 Ø 3/8" EST. Ø 1/4" @ 0.15

0.20
C5
Ø 1/4" @ 0.15 Ø 1/4" @ 0.15 Ø 1/4" @ 0.15

0.20

0.20
C3 C3

3.35

0.10
C3 C3 C3
C3

CARRERA: INGENIERIA CIVIL


C3 C3
C5
Z2 Z2
COLUMNA C-6
Z1 Z1
C3
SOLERA S-1 SOLERA DE AMARRRE S. A.
ESC: 1/10 SOLERA DE CIMENTACION

2
C1 C1
C1
C2 C3 C2
C1
C2 C2 ESC: 1/10 ESC: 1/10 ESC: 1/10
6.15

6.15
C3 C3 C5

3.37

3.37
C3 C5 C5
C3 C3 C3

Z1 C5
Z1
Z2 Z2 C3

C1 C1 C2 C2 C2 C3

1
1

1
C2 C4 C2 C2

-
NIV.+0.00

202241090
6.78 3.29 2.40 3.20 4.47

10.22 10.22

CARNE:
SOLERA DE HUMEDAD

0.20
A E G A B D G 4 Ø 3/8" EST. Ø 1/4"@ 0.20
(IGUAL ARMADO SOLERA DE CIMENTACION)

PLANTA DE CIMENTACIÓN
PRIMER NIVEL / ESCALA 1/125 PLANTA DE CIMENTACIÓN BLOCK DE PIEDRA DE
SEGUNDO NIVEL / ESCALA 1/1OO

0.63
0.15 X 0.20 X 0.40
AGUJEROS RELLENOS
1.00
PROYECCION DE
COLUMNA

C C' PROYECCION DE

A C F CIMIENTO CORRIDO CIMIENTO

0.20
HIERRO DE 1/2" @ 0.10
3 Ø 3/8" ESL. Ø 3/8"@ 0.20
AMBOS SENTIDOS

1.00
9 Ø 1/2" AMBOS

0.20
SENTIDOS

0.40
1.00

CIMIENTO CORRIDO TIPO 1 ESC:1/10


.20

ZAPATA TIPO Z-1ESC: 1/10 SECCION C-C' ZAPATA TIPO Z-1


.84

LOSA PREFABRICADA
.20

S-1
S-1 .90

PUERTA DE PLYWOOD

30/08/2022
0.84
1.27

ESCALA: /
FECHA:
REPELLO + ALIZADO REPELLO + ALIZADO

1.67

2.46
.20

S-1 S-1
2.25

1.62
1.26
7.10

.58
A
VIGA V-1

5
.20

S-1 S-1
S-1
2.02
.47
1.27

REPELLO + ALIZADO S-1


.20

S-1 S-1
2.26
2.25
1.26

CATEDRATICO: ARQ. ANGEL MIGUEL PONCE


ANTHONY EMMANUEL CAHUEC CAAL
S-1
.20

.20

.20
S-1 S-1

SECCION A-A´

.84

.84
ESCALA 1/ 100 SOLERA CORONA

.20

.63 .20
S-C

1.27
1 3 4 5

1.47
.20
SOLERA INTERMEDIA

DIBUJO:
1.26
7.10

7.10

.20 .63
.20
S-C
1.04

1.04

LOSA PREFABRICADA LOSA PREFABRICADA


SOLERA CORONA
.20

.63
.32 S-1 S-1 S-1
.47

DINTEL

1.27
1.47
1.58

.84

.20
2.73
1.67

SOLERA INTERMEDIA
.20
REPELLO + ALIZADO S-1 S-1 REPELLO + ALIZADO S-1

2.10
1.41

1.26
1.15

LEVANTADO DE MURO DE BLOCK


7.10

CUNOR USAC
7.30

.59

1.26

DE 0.15 X 0.20 X 0.40


V-1 V-1 V-1
.62

.62

S-1
.20

.20
SOLERA DE HUMEDAD S-H
1.68

REPELLO + ALIZADO
3.13

LEVANTADO DE MURO DE CIMENTACION

1.04
S-1 REPELLO + ALIZADO
2.67

2.26

1.04

20 .64
2.31

.20 20 .64

BASE DE CIMENTACIÓN BASE DE CIMENTACION


S-1
ZAPATA Z-1
.58

.20

DETALLE DE MURO EJE 5


S-1 S-1 S-1 DETALLE DE MURO TIPICO
S-1 ESC: 1/10
ESC: 1/10
S-1

SECCION B-B´
ESCALA 1/ 100